tracker reconstruction
DESCRIPTION
Timothy Carlisle Oxford. Tracker Reconstruction. Reconstruction in G4MICE. Simulate Digitize Reconstruct TrackerRec / package 4 or 5 point tracks ( Kalman fit) root files for each Tracker Station No TrackerRef Plane as yet Use station 1 as ref. innermost stations. - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Tracker Reconstruction](https://reader035.vdocument.in/reader035/viewer/2022081512/56815efe550346895dcdbca7/html5/thumbnails/1.jpg)
Tracker ReconstructionTimothy CarlisleOxford
![Page 2: Tracker Reconstruction](https://reader035.vdocument.in/reader035/viewer/2022081512/56815efe550346895dcdbca7/html5/thumbnails/2.jpg)
Reconstruction in G4MICE
Simulate Digitize Reconstruct TrackerRec/ package 4 or 5 point tracks (Kalman fit) ROOT files for each Tracker Station
No TrackerRef Plane as yet Use station 1 as ref. innermost stations
![Page 3: Tracker Reconstruction](https://reader035.vdocument.in/reader035/viewer/2022081512/56815efe550346895dcdbca7/html5/thumbnails/3.jpg)
Track Fitting Efficiency Downstream Tracker Upstream Tracker
10,000 muons 6mm beamTwo Trackers, no materialStep IV fields
Inner station Inner station
99% 99%
![Page 4: Tracker Reconstruction](https://reader035.vdocument.in/reader035/viewer/2022081512/56815efe550346895dcdbca7/html5/thumbnails/4.jpg)
x Resolution
10,000 events, e =6mm Res. 0.7 mm at stations 1
& 2 Res. ~1.2 mm at outer
stations Feature of fitting
algorithm?
Station 5
Station 1
10,000 muons 6mm beamStep IV fields
![Page 5: Tracker Reconstruction](https://reader035.vdocument.in/reader035/viewer/2022081512/56815efe550346895dcdbca7/html5/thumbnails/5.jpg)
Momentum Resolution
Px Pz
• (mcPx-TrkPx) ~ 1 MeV/c • (mcPz-TrkPz) ~3.7MeV/c
10,000 muons 6mm beamStep IV fields
![Page 6: Tracker Reconstruction](https://reader035.vdocument.in/reader035/viewer/2022081512/56815efe550346895dcdbca7/html5/thumbnails/6.jpg)
dE/dX? Landau distribution is ~3
MeV wide Ptotal resolution ~ 3.9 MeV/c Pz res. the weak link EMR / ToFs?
Ptotal
![Page 7: Tracker Reconstruction](https://reader035.vdocument.in/reader035/viewer/2022081512/56815efe550346895dcdbca7/html5/thumbnails/7.jpg)
Transverse Amplitude
Single particle emittance Useful for selection cuts Beastly:
Calc. using mc truth a b g for beam envelope
![Page 8: Tracker Reconstruction](https://reader035.vdocument.in/reader035/viewer/2022081512/56815efe550346895dcdbca7/html5/thumbnails/8.jpg)
Amplitude Resolution
0.3mm < DAmpSq< 0.8mm depending on the station Unclear why sign change... 10,000 muons
6mm beamStep IV fields
Station 1 (Inner)
Station 5
![Page 9: Tracker Reconstruction](https://reader035.vdocument.in/reader035/viewer/2022081512/56815efe550346895dcdbca7/html5/thumbnails/9.jpg)
[Crude] Cooling Measurements
10,000 muons 6mm beamTwo Trackers, LH2Step IV fields
Black – mc [Virtual Planes], 98.5% Transmitted
Green – Trk mcBlue – reconstructed
Emittance[mm]
• 35cm LH2•Calc. e at each station•Inner station ref. plane•4.5% cooling (mc truth)
•TrkMC: 5.5%•TrkRec: 3.8%
Abs(mc – rec) < 50 for x, y, px , py
![Page 10: Tracker Reconstruction](https://reader035.vdocument.in/reader035/viewer/2022081512/56815efe550346895dcdbca7/html5/thumbnails/10.jpg)
Energy
Av. Energy [MeV]
few MeV loss due to stations
Rec. Energy ~ const. Averaged for rec.
tracks?Black – mc [Virtual Planes]
Green – Trk mc Blue – Trk reconstructed
![Page 11: Tracker Reconstruction](https://reader035.vdocument.in/reader035/viewer/2022081512/56815efe550346895dcdbca7/html5/thumbnails/11.jpg)
Summary TrackerRec/ Station by Station output at present Efficiency 98-99% Position resolution dep. on station At inner station:
Energy resolution ~ 4MeV Beyond Landau width- use EMR / ToFs?
Amplitude resolution appears < 1mm
• sDx, Dy~0.7mm • sDPx, DPy ~ 1 MeV/c• sDPz ~ 3.7 MeV/c