trane downflow/horizontal condensing, gas-fired furnace

14
Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 TDC1B040A9241A, TDC1B060A9361A TDC1B080A9421A, TDC1C100A9481A TDC1D120A9601A Single-Stage Fan Assisted Combustion System PUB. NO. 22-1670-04 TDD-D-1

Upload: others

Post on 03-Feb-2022

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Trane Downflow/Horizontal Condensing, Gas-Fired Furnace

Downflow/HorizontalCondensing,Gas-Fired Furnace

XB 90TDC1B040A9241A, TDC1B060A9361ATDC1B080A9421A, TDC1C100A9481ATDC1D120A9601A

Single-Stage Fan AssistedCombustion System

PUB. NO. 22-1670-04

TDD-D-1

Page 2: Trane Downflow/Horizontal Condensing, Gas-Fired Furnace

2 Pub. No. 22-1670-04

GeneralFeatures

©American Standard Inc. 2007

NATURAL GAS MODELSCentral Heating furnace designs arecertified by the American Gas Associationfor both natural and L.P. gas. Limitsetting and rating data were establishedand approved under standard ratingconditions using American NationalStandards Institute standards.

SAFE OPERATIONThe Integrated System Control has solidstate devices, which continuously monitorfor presence of flame, when the systemis in the heating mode of operation. Dualsolenoid combination gas valve andregulator provide extra safety.

QUICK HEATINGDurable, cycle tested, heavy gaugealuminized steel heat exchangerquickly transfers heat to provide warmconditioned air to the structure. Lowenergy power vent blower, to increaseefficiency and provide a positivedischarge of gas fumes to the outside.

BURNERSMultiport Inshot burners will give years ofquiet and efficient service. All modelscan be converted to L.P. gas withoutchanging burners.

INTEGRATED SYSTEM CONTROLExclusively designed operationalprogram provides total control of furnacelimit sensors, blowers, gas valve, flamecontrol and includes self diagnostics forease of service. Also containsconnection points for E.A.C./humidifier.

AIR DELIVERYThe variable speed, direct drive blowermotor, has sufficient airflow for mostheating and cooling requirements, willswitch from heating to cooling speeds ondemand from room thermostat. Theblower door safety switch will prevent orterminate furnace operation when theblower door is removed.

STYLINGHeavy gauge steel and “wrap-around”cabinet construction is used in thecabinet with baked-on enamel finish forstrength and beauty. The heat exchangersection of the cabinet is completely linedwith foil faced fiberglass insulation. Thisresults in quiet and efficient operationdue to the excellent acoustical andinsulating qualities of fiberglass. Built-inbottom pan and alternate bottom, left orright side return air connection provision.

FEATURES ANDGENERAL OPERATIONThe XV 80 High Efficiency Gas Furnacesemploy a Hot Surface Ignition system,which eliminates the waste of a constantburning pilot. The integrated systemcontrol lights the main burners upon ademand for heat from the roomthermostat. Complete front serviceaccess.a. Low energy power venterb. Vent proving pressure switch.

Page 3: Trane Downflow/Horizontal Condensing, Gas-Fired Furnace

3Pub. No. 22-1670-04

Contents

Feature Summary

Features and BenefitsStandard EquipmentOptional Equipment

General DataTDC1B040A9241ATDC1B060A9361ATDC1B080A9421ATDC1C100A9481ATDC1D120A9601A

Performance Data

Electrical Data

Field Wiring

Dimensions

2

4

6

8

9

11

13

Page 4: Trane Downflow/Horizontal Condensing, Gas-Fired Furnace

4 Pub. No. 22-1670-04

Featuresand Benefits

XB 90 STANDARD EQUIPMENT• Downflow power supply 115/1/60

• Downflow convertible to horizontal onleft side

• Type 29-4CTM stainless steel

secondary heat exchanger

• Inner blower doors

• Direct drive, 4-speed motor

• Hot surface igniter with adaptive heatup

• Accessory hook-up capability - Humand EAC

• Quiet induced draft blower

• Blower door safety switch

• Dual solenoid combination gas valve& regulator

• PVC venting - 1 Pipe

• Left/right gas connection

• Selectable cooling fan off delayeliminates need for BAY24X045 timedelay relay

• Integrated solid state control withself diagnostics

• 24 volt fuse

• Manual reset burner box limit

• Lifetime limited primary heatexchanger or secondary heatexchanger warranty to originalowner (Residential use)

• 3-year limited warranty onintegrated ignition control andhot surface igniter(Residential use)

• Optional extended warranties

Page 5: Trane Downflow/Horizontal Condensing, Gas-Fired Furnace

5Pub. No. 22-1670-04

Featuresand Benefits

XB 90 OPTIONAL EQUIPMENT

Thermostat, Mechanical Heating Only With Fan Switch ............................................................................................ BAYSTAT303 [ ]Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) ................................................................................. AY28X092 [ ]Thermostat, Heating/Cooling Single Stage (Mounts Vertically) ................................................................................ BAYSTAT305 [ ]Thermostat, Electronic Programmable 1-Stage Heating/1-Stage Cooling ............................................................... BAYSTAT300 [ ]Propane Conversion Kit ........................................................................................................................................ BAYLPKT210A [ ]Electronic Air Filter, “Perfect Fit” Super Efficiency (17-1/2" Wide Gas Furnace) ....................................................... TFE175A9FR0 [ ]Electronic Air Filter, “Perfect Fit” Super Efficiency (21" Wide Gas Furnace) ............................................................. TFE210A9FR0 [ ]Electronic Air Filter, “Perfect Fit” Super Efficiency (24-1/2" Wide Gas Furnace) ....................................................... TFE245A9FR0 [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace) ........................................................ TFM175A9FR0 [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace) .............................................................. TFM210A9FR0 [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace) ........................................................ TFM245A9FR0 [ ]Electronic Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace) .................................................. TFP175A9FR0 [ ]Electronic Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace) ........................................................ TFP210A9FR0 [ ]Electronic Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace) .................................................. TFP245A9FR0 [ ]Coil Enclosure (17-1/2" Wide Cabinets) ...................................................................................................................BAYCLE1700 [ ]Coil Enclosure (21" Wide Cabinets) .........................................................................................................................BAYCLE2100 [ ]Coil Enclosure (24-1/2" Wide Cabinets) ...................................................................................................................BAYCLE2400 [ ]Side Filter Rack ........................................................................................................................................................ BAYFLTR200 [ ]High Altitude Switch ................................................................................................................................................. BAYHALT239 [ ]

Page 6: Trane Downflow/Horizontal Condensing, Gas-Fired Furnace

6 Pub. No. 22-1670-04

GeneralData

1 Central Furnace heating designs are certified by the American Gas Association Inc. Laboratories.2 Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet; Ratings should be reduced at the rate of 4% for each 1000 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.

MODELTYPERATINGS 22222Input BTUHCapacity BTUH (ICS) 33333AFUETemp. rise (Min.-Max.) °F.BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / HzCOMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLAFILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)VENT — Size (in.)HEAT EXCHANGERType-Fired

-UnfiredGauge (Fired)ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill SizeGAS VALVEPILOT SAFETY DEVICETypeBURNERS — TypeNumberPOWER CONN. — V / Ph / Hz 44444Ampacity (In Amps)Max Overcurrent Protection (Amps)PIPE CONN. SIZE (IN.)DIMENSIONSCrated (In.)WEIGHTShipping (Lbs.) / Net (Lbs)

PRODUCT SPECIFICATIONS 11111TDC1B040A9241A

Downflow / Horizontal

40,00038,00090.0

30 - 60DIRECT10 x 7

14

See Fan Performance Table1/5

1080115/1/60

CentrifugalDirect - 1

1/55 - 3000115/1/60

1.0No

High Velocity2 - 14x20 - 1in.

2 Round

Aluminized Steel - Type I

20

2 — 452 — 56

Redundant - Single Stage

Hot Surface IgnitionMultiport Inshot

2115/1/60

4.7151/2

H x W x D41-3/4 x 19-1/2 x 30-1/2

145 / 135

TDC1B060A9361ADownflow / Horizontal

60,00056,00090.0

35 - 65DIRECT10 x 8

14

See Fan Performance Table1/3

1075115/1/60

CentrifugalDirect - 1

1/55 - 3000115/1/60

1.0No

High Velocity2 - 14x20 - 1in.

2 Round

Aluminized Steel - Type I

20

3 — 453 — 56

Redundant - Single Stage

Hot Surface IgnitionMultiport Inshot

3115/1/60

9.1151/2

H x W x D41-3/4 x 19-1/2 x 30-1/2

155 / 145

TDC1B080A9421ADownflow / Horizontal

80,00074,00090.0

35 - 65DIRECT11 x 8

14

See Fan Performance Table1/2

1075115/1/60

CentrifugalDirect - 1

1/25 - 3200115/1/60

1.35No

High Velocity2 - 14x20 - 1in.

2 Round

Aluminized Steel - Type I

20

4 — 454 — 56

Redundant - Single Stage

Hot Surface IgnitionMultiport Inshot

4115/1/60

11.4151/2

H x W x D41-3/4 x 19-1/2 x 30-1/2

168 / 158

Page 7: Trane Downflow/Horizontal Condensing, Gas-Fired Furnace

7Pub. No. 22-1670-04

GeneralData

1 Central Furnace heating designs are certified by the American Gas Association Inc. Laboratories.2 Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet; Ratings should be reduced at the rate of 4% for each 1000 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.

MODELTYPERATINGS 22222Input BTUHCapacity BTUH (ICS) 33333AFUETemp. rise (Min.-Max.) °F.BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / HzCOMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLAFILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)VENT — Size (in.)HEAT EXCHANGERType-Fired

-UnfiredGauge (Fired)ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill SizeGAS VALVEPILOT SAFETY DEVICETypeBURNERS — TypeNumberPOWER CONN. — V / Ph / Hz 44444Ampacity (In Amps)Max Overcurrent Protection (Amps)PIPE CONN. SIZE (IN.)DIMENSIONSCrated (In.)WEIGHTShipping (Lbs.) / Net (Lbs)

PRODUCT SPECIFICATIONS 11111*DC1D120A9601A

Downflow / Horizontal

120,000110,000

90.040 - 70

DIRECT11 x 10

14

See Fan Performance Table1/2

1075115/1/60

CentrifugalDirect - 1

1/20 - 3450115/1/60

0.71No

High Velocity2 - 16x20 - 1in.

3 Round

Aluminized Steel - Type I

20

6 — 456 — 56

Redundant - Single Stage

Hot Surface IgnitionMultiport Inshot

6115/1/60

12.9151/2

H x W x D41-3/4 x 26-1/2 x 30-1/2

206 / 196

*DC1C100A9481ADownflow / Horizontal

100,00093,00090.0

35 - 65DIRECT11 x 10

14

See Fan Performance Table1/2

1075115/1/60

CentrifugalDirect - 1

1/20 - 3450115/1/60

0.71No

High Velocity2 - 16x20 - 1in.

2 Round

Aluminized Steel - Type I

20

5 — 455 — 56

Redundant - Single Stage

Hot Surface IgnitionMultiport Inshot

5115/1/60

12.5151/2

H x W x D41-3/4 x 23 x 30-1/2

185 / 175

Page 8: Trane Downflow/Horizontal Condensing, Gas-Fired Furnace

8 Pub. No. 22-1670-04

PerformanceData

FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (in. w.c.)

MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90

TDC1B040A9241A 4 -3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

998856753647

965832728617

922797694581

870751650538

807695596490

735628533435

653550460375

561462378308

459363286235

TDC1B060A9361A 4 -3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

134111981369784

128511611232781

122311151108767

11561060998741

1082996901703

1004923817654

919842747593

829751689521

734652645437

TDC1B080A9421A 4 -3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

1547148713881263

1498143613481234

1445138213021196

1386132512491150

1323126511911095

1254120211261032

118011371056960

11011069979879

1016998896790

TDC1C100A9481A 4 -3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

1892177916301444

1827172615871416

1762167215441388

1688160514851348

1614153814261308

1531146013621246

1448138112971184

1354129112081108

1260120011191032

TDC1D120A9601A 4 -3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

2213205717651468

2138200017331452

2062194317001435

2001188316521409

1939182216031382

1863175215521336

1786168115001290

1706159514241225

1625150813471159

CFM VS. TEMPERATURE RISE

MODELCubic Feet Per Minute (CFM)

600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400

TDC1B040A9241A 56 48 42 37 34

TDC1B060A9361A 63 56 51 46 42 39 36 34

TDC1B080A9421A 61 56 52 48 45 42 40 37 35

TDC1C100A9481A 65 60 56 53 50 47 44 42 40 38 37 35

TDC1D120A9601A 67 63 59 56 53 51 48 46 44 42

Page 9: Trane Downflow/Horizontal Condensing, Gas-Fired Furnace

9Pub. No. 22-1670-04

SCHEMATIC DIAGRAMS FOR GAS FURNACES

ElectricalData

Page 10: Trane Downflow/Horizontal Condensing, Gas-Fired Furnace

10 Pub. No. 22-1670-04

SCHEMATIC DIAGRAMS FOR GAS FURNACES

ElectricalData

Page 11: Trane Downflow/Horizontal Condensing, Gas-Fired Furnace

11Pub. No. 22-1670-04

FieldWiring

FIELD WIRING DIAGRAM FOR HEATING ONLY

From Dwg.. 21B340388 Rev. 1

FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING/COOLING(OUTDOOR SECTION WITHOUT TRANSFORMER)

From Dwg.. 21B340387 Rev. 1

TO 115 V 1 PH.,60 HZ., POWERSUPPLY PERLOCAL CODES

HUM SEENOTE 5

EAC SEENOTE 5

TO 115 V 1 PH.,60 HZ., POWERSUPPLY PERLOCAL CODES

HUM SEENOTE 5

EAC SEENOTE 5

Page 12: Trane Downflow/Horizontal Condensing, Gas-Fired Furnace

12 Pub. No. 22-1670-04

FieldWiring

From Dwg.. 21B341423 Rev. 1

From Dwg.. 21B341422 Rev. 1

Page 13: Trane Downflow/Horizontal Condensing, Gas-Fired Furnace

13Pub. No. 22-1670-04

Dimensions

TDC1 OUTLINE DRAWING(ALL DIMENSIONS ARE IN INCHES)

From Dwg. 21C340462 Rev. 6

MODEL A B C D

TDC1B040A9241ATDC1B060A9361ATDC1B080A9421A

17-1/2" 2-1/4" 16-1/4" 16"

TDC1C100A9481A 21" 2-1/2" 19-3/4" 19-1/2"

TDC1D120A9601A 24-1/2" 2-15/16" 23-1/4" 23"

Page 14: Trane Downflow/Horizontal Condensing, Gas-Fired Furnace

Since The Trane Company has a policy of continuous product and product data improvement, it reserves theright to change design and specifications without notice.

Trane

A business of American Standard companies6200 Troup HighwayTyler, TX 75707www.trane.com

File No. PL-UN-FURN-TDD-D-1 3/98 P.I. 04/07