transducer electronic data sheet (teds)

1
INTERFACE 7401 E. Butherus Drive, Scottsdale, AZ 85260 PHONE: (480) 948-5555 FAX: (480) 948-1924 www.interfaceforce.com Email: [email protected] ORDER TOLL-FREE 1-800-947-5598 TEDS_118 9/7/06 Page 1 of 2 The Leader in Force Measurement Interface has offered sensors with various types of SELF-ID for many years. The SELF-ID features eliminates the need to enter data via a keyboard or key panel from a paper calibration sheet into the instrument used with the load cell. This feature offers the following benefits: Eliminates potential for data entry error Cuts time in half to set up instrument Makes swapping of load cells easy Increases safety by making certain that system has the correct capacity of the load cell Can be used to identify location of load cell No need to store calibration sheets, no more paper, no more concern about lost sheets Makes inventory control of your load cells easy Load cells can be changed out without jeopardizing integrity of system Now TEDS provides additional advantages over proprietary SELF-ID because it is an industry standard (IEEE 1451.4) which has the potential to permit mix and matching of load cells and instruments from different manufacturers. IEEE1451.4 specifies a table of identifying parameters that are stored in the load cell in the form of a TEDS (Transducer Electronic Data Sheet). TEDS is a table of parameters that identify the transducer and is held in the transducer on a EEprom for interrogation by external electronics. Transducer Electronic Data Sheet (TEDS) SELF-ID Load Cell Load cell with electronic identification inside Meets IEEE 1451.4 standard for smart transducer interface Available on new or existing load cells Plug & Play Ready Cuts instrument setup time Eliminates data entry error Sensor information and calibration data Actual size compared to standard load cell

Upload: interface

Post on 16-Jul-2015

89 views

Category:

Technology


8 download

TRANSCRIPT

Page 1: Transducer Electronic Data Sheet (TEDS)

INTERFACE • 7401 E. Butherus Drive, Scottsdale, AZ 85260 • PHONE: (480) 948-5555 • FAX: (480) 948-1924

www.interfaceforce.com • Email: [email protected] • ORDER TOLL-FREE 1-800-947-5598TEDS_118

9/7/06Page 1 of 2

The Leader in Force Measurement

Interface has offered sensors with various types of SELF-ID for many years. The SELF-ID featureseliminates the need to enter data via a keyboard or key panel from a paper calibration sheet into theinstrument used with the load cell. This feature offers the following benefits:• Eliminates potential for data entry error• Cuts time in half to set up instrument• Makes swapping of load cells easy• Increases safety by making certain that system has the correct capacity of the load cell• Can be used to identify location of load cell• No need to store calibration sheets, no more paper, no more concern about lost sheets• Makes inventory control of your load cells easy• Load cells can be changed out without jeopardizing integrity of system

Now TEDS provides additional advantages over proprietary SELF-ID because it is an industry standard(IEEE 1451.4) which has the potential to permit mix and matching of load cells and instruments fromdifferent manufacturers.

IEEE1451.4 specifies a table of identifying parameters that are stored in the load cell in the form of a TEDS(Transducer Electronic Data Sheet). TEDS is a table of parameters that identify the transducer and is held inthe transducer on a EEprom for interrogation by external electronics.

Transducer Electronic Data Sheet (TEDS)SELF-ID Load Cell

• Load cell with electronicidentification inside

• Meets IEEE 1451.4 standard for smart transducer interface

• Available on new or existing load cells• Plug & Play Ready• Cuts instrument setup time• Eliminates data entry error• Sensor information and calibration data

Actual size compared to standard load cell