transistor inverter - toshiba-tips.co.jp · transistor inverter printed in japan to users of our...

2
Transistor Inverter Printed in Japan To users of our inverters : Our inverters are designed to control the speeds of three-phase induction motors for general industry. For further information, please contact your nearest Toshiba Representative or International Operations-Producer Goods. The information in this brochure is subject to change without notice. * Read the instruction manual before installing or operating the inverter unit and store it in a safe place for reference. * When using our inverters for equipment such as nuclear power control, aviation and space flight control, traffic, and safety, and there is a risk that any failure or malfunction of the inverter could directly endanger human life or cause injury, please contact our headquarters, branch, or office printed on the front and back covers of this catalogue. Special precautions must be taken and such applications must be studied carefully. * When using our inverters for critical equipment, even though the inverters are manufactured under strict quality control always fit your equipment with safety devices to prevent serious accident or loss should the inverter fail (such as issuing an inverter failure signal). * Do not use our inverters for any load other than three-phase induction motors. * None of Toshiba, its subsidiaries, affiliates or agents, shall be liable for any physical damages, including, without limitation, malfunction, anomaly, breakdown or any other problem that may occur to any apparatus in which the Toshiba inverter is incorporated or to any equipment that is used in combination with the Toshiba inverter. Nor shall Toshiba, its subsidiaries, affiliates or agents be liable for any compensatory damages resulting from such utilization, including compensation for special, indirect, incidental, consequential, punitive or exemplary damages, or for loss of profit, income or data, even if the user has been advised or apprised of the likelihood of the occurrence of such loss or damages. Precautions ■Standard connection diagram : Source logic(common : P24) ■External dimensions and weight Inverter type 0.4 VFFS1-2004PM 107 130 150 1.2 0.75 VFFS1-2007PM 107 130 150 1.2 1.5 VFFS1-2015PM 107 130 150 1.2 2.2 VFFS1-2022PM 107 130 150 1.2 4.0 VFFS1-2037PM 142 170 150 2.1 5.5 VFFS1-2055PM 180 220 170 4.3 7.5 VFFS1-2075PM 180 220 170 4.3 11 VFFS1-2110PM 245 310 190 8.6 15 VFFS1-2150PM 245 310 190 8.6 18.5 VFFS1-2185PM 245 310 190 8.9 22 VFFS1-2220PM 240 420 214 16.4 30 VFFS1-2300PM 320 630 290 38.7 0.4 VFFS1-4004PL 107 130 150 1.4 0.75 VFFS1-4007PL 107 130 150 1.4 1.5 VFFS1-4015PL 107 130 150 1.4 2.2 VFFS1-4022PL 107 130 150 1.4 4.0 VFFS1-4037PL 142 170 150 2.4 5.5 VFFS1-4055PL 142 170 150 2.4 7.5 VFFS1-4075PL 180 220 170 4.7 11 VFFS1-4110PL 180 220 170 4.7 15 VFFS1-4150PL 245 310 190 9.0 18.5 VFFS1-4185PL 245 310 190 9.0 22 VFFS1-4220PL 240 420 214 15.4 30 VFFS1-4300PL 240 420 214 15.4 37 VFFS1-4370PL 240 550 214 23.5 45 VFFS1-4450PL 240 550 214 23.5 55 VFFS1-4550PL 320 630 290 40 75 VFFS1-4750PL 320 630 290 40 ■Standard connection diagram : Sink logic(common : cc) Main circuit power supply 200V class: three-phase 200-240V -50/60Hz 400V class: three-phase 380-480V -50/60Hz Applicable motor(kW) Input voltage Class Approximate weight(kg) 3-phase 200V (IP20/IP00) 3-phase 400V (IP20/IP00) Dimensions(mm) Width Height Depth Inverter type 0.75 VFFS1-4007PL1E 5.3 VFFS1-4007PDE 5.6 1.5 VFFS1-4015PL1E 215 297 192.3 5.3 VFFS1-4015PDE 5.6 2.2 VFFS1-4022PL1E 5.3 VFFS1-4022PDE 5.6 3.7 VFFS1-4037PL1E 7.2 VFFS1-4037PDE 8.1 5.5 VFFS1-4055PLE 7.2 VFFS1-4055PDE 230 340 208.3 8.1 7.5 VFFS1-4075PLE 8.5 VFFS1-4075PDE 9.4 11 VFFS1-4110PLE 21.0 VFFS1-4110PDE 25.5 15 VFFS1-4150PLE 295.3 560 292.9 21.0 VFFS1-4150PDE 25.5 18.5 VFFS1-4185PLE 28.5 VFFS1-4185PDE 315 665 293.4 33.5 22 VFFS1-4220PLE 29.0 VFFS1-4220PDE 33.5 30 VFFS1-4300PLE 285 720 289.4 29.0 VFFS1-4300PDE 33.5 37 VFFS1-4370PLE 38.1 VFFS1-4370PDE 43.5 45 VFFS1-4450PLE 285 880 334 38.1 VFFS1-4450PDE 43.5 55 VFFS1-4550PLE 58.0 VFFS1-4550PDE 69.1 75 VFFS1-4750PLE 362 1000 354 58.0 VFFS1-4750PDE 69.1 Applicable motor(kW) Input voltage Class Approximate weight(kg) 3-phase 400V (IP54) Dimensions(mm) Width Height Depth ■Standard specifications Item Specification Applicable motor (kW) 0.4 0.75 1.5 2.2 4.0 5.5 7.5 11 15 18.5 22 30 37 45 55 75 Input voltage class Type VFFS1 3-phase 200V class VFFS1- 2004PM 2007PM 2015PM 2022PM 2037PM 2055PM 2075PM 2110PM 2150PM 2185PM 2220PM 2300PM 3-phase 400V class(IP20/IP00) VFFS1- 3-phase 400V class VFFS1- (IP54) Capacity (kVA) 200V class/400V class Output current (A) 3-phase 200V class 3-phase 400V class Type Form Rating Power supply Note3) 400V class(IP54): -10 to 50℃(Current decrease when over 40℃) Note2) The rated output current is at default setting of PWM carrier frequency( ).15kW or less:12kHz, 18.5kW or more:8kHz. The rated output current in the parenthesis is at 12kHz of PWM carrier frequency( )setting. Note1) Refer to “Built-in filter”for difference between PLE/PL1E type and PDE type. FLA PLC PLC FM CC VIA VIB PP FLB FLC MCCB R/L1 S/L2 T/L3 U/T1 Motor V/T2 W/T3 RY P24 RC PA/+ Noise filter Power circuit Control circuit Operation panel Connector for RS485(2wire) communications SW4 SOURCE SINK FM VIA SW2 SW3 V I V I PC/- IM VF-FS1 Protective function activation output Low-speed signal output 24Vdc input Meter 7.5V-1mA (or 4-20mA) Voltage signal : 0-10V (Current signal : 4-20mA) External potentiometer(1-10kΩ) (or input voltage signal across VIB-CC terminal : 0-10V) F R RES CC Forward Reverse Reset Common Frequency meter (ammeter) PLC SOURCE SINK CC P24 F R RES Forward Reverse Reset Note2) Note1) 200V class: 200V to 240V - 50/60Hz, 400V class: 3-phase 380 to 480V - 50/60Hz Voltage +10%, -15% (±10% when the inverter is used continuously (load of 100%)),Flequency ±5% Voltage/frequency Allowable fluctuation Output voltage adjustment Adjustable within a range of the corrected supply voltage 50 to 660V (Unadjustable to any voltage higher than the input voltage). Output frequency range 0.5 to 200.0Hz (default setting 0.5 to 80.0Hz)  Voltage/frequency characteristics V/f constant, variable torque, automatic torque boost, vector control, automatic energy conservation, PM motor control, auto-tuning function Overload current rating 60 seconds at 110%, 2 seconds at 180% Main functions Wizard, Local/Remote change-over, Bumpless operation, Forced fire-speed control, PTC thermal protection, Programmable I/O terminal block, Auto-restart Ambient temperature/Relative humidity -10 to 60℃ (Current decrease when over 40℃) Note3) /5 to 95% free from condensation and vapor Protective method Cooling method Forced air cooling(PL1E type:self-cooling) Built-in filter PM type:Basic noise filter. PL,PL1E,PLE(5.5,7.5kW):EMI filter (EN61800-3 1st Environment C2 or 2nd Environment C3), PLE(11kW or more) type:EMI filter (EN61800-3 2nd Environment C3). PDE type:EMI filter (EN61800-3 1st Environment C1) PM,PL type:IP20(0.4 to 18.5kW), IP00(22kW or more) PLE,PL1E,PDE type:IP54 4004PL 4007PL 4015PL 4022PL 4037PL 4055PL 4075PL 4110PL 4150PL 4185PL 4220PL 4300PL 4370PL 4450PL 4550PL 4750PL 4007PL1E 4015PL1E 4022PL1E 4037PL1E 4055PLE 4075PLE 4110PLE 4150PLE 4185PLE 4220PLE 4300PLE 4370PLE 4450PLE 4550PLE 4750PLE 4007PDE 4015PDE 4022PDE 4037PDE 4055PDE 4075PDE 4110PDE 4150PDE 4185PDE 4220PDE 4300PDE 4370PDE 4450PDE 4550PDE 4750PDE 1.1 1.8/1.6 2.9/2.8 4.0/3.9 6.7/6.9 9.2/9.1 12.2 17.6/17.1 23.2 28.5/28.2 33.5/33.2 44.6 -/60.2 -/71.6 -/88.4 -/121.9 2.8 4.6 7.5 10.6 17.5 24.2 32 46.2 61 74.8(67.3) 88(79.2)117.0(105.3) 1.4 2.2 3.7 5.1 9.1 12 16 22.5 30.5 37(33.3)43.5(39.2)58.5(52.7)79.0(71.1)94.0(84.6)116.0(104.4)160.0(128.0) 3-phase 200V class(IP20/IP00)0.4kW to 30kW 3-phase 400V class(IP20/IP00)0.4kW to 75kW 3-phase 400V class(IP54) 0.75kW to 75kW TOSVERT™ inverter dedicated to fan and pump for HVAC This product is designed and manufactured in factories that have acquired certification of “ISO-9001”, the international quality assurance standard. The factories manufacturing this product are ISO-14001, environmental management system, registered factories. ISO-9001 Certification Acquired ISO-14001 Certification Acquired International Operations 9-11, Nihonbashi-honcho 4-chome, Chuo-ku, Tokyo 103-0023, Japan Tel : +81-(0)3-5644-5509 Fax : +81-(0)3-5644-5519 TOSHIBA INDUSTRIAL PRODUCTS SALES CORPORATION AB 08-02 (AB)8697A Totally enclosed box type for IP54

Upload: nguyenkiet

Post on 10-Jun-2019

232 views

Category:

Documents


0 download

TRANSCRIPT

Transistor Inverter

Printed in Japan

To users of our inverters : Our inverters are designed to control the speeds of three-phase induction motors for general industry.

For further information, please contact your nearest Toshiba Representative or International Operations-Producer Goods.The information in this brochure is subject to change without notice.

* Read the instruction manual before installing or operating the inverter unit and store it in a safe place for reference.* When using our inverters for equipment such as nuclear power control, aviation and space flight control, traffic, and safety, and there is a risk that any failure or malfunction of the inverter could

directly endanger human life or cause injury, please contact our headquarters, branch, or office printed on the front and back covers of this catalogue. Special precautions must be taken and such applications must be studied carefully.

* When using our inverters for critical equipment, even though the inverters are manufactured under strict quality control always fit your equipment with safety devices to prevent serious accident or loss should the inverter fail (such as issuing an inverter failure signal).

* Do not use our inverters for any load other than three-phase induction motors.* None of Toshiba, its subsidiaries, affiliates or agents, shall be liable for any physical damages, including, without limitation, malfunction, anomaly, breakdown or any other problem that may occur to

any apparatus in which the Toshiba inverter is incorporated or to any equipment that is used in combination with the Toshiba inverter. Nor shall Toshiba, its subsidiaries, affiliates or agents be liable for any compensatory damages resulting from such utilization, including compensation for special, indirect, incidental, consequential, punitive or exemplary damages, or for loss of profit, income or data, even if the user has been advised or apprised of the likelihood of the occurrence of such loss or damages.

Precautions!

■Standard connection diagram : Source logic(common : P24)

■External dimensions and weight

Inverter type

0.4 VFFS1-2004PM 107 130 150 1.2

0.75 VFFS1-2007PM 107 130 150 1.2

1.5 VFFS1-2015PM 107 130 150 1.2

2.2 VFFS1-2022PM 107 130 150 1.2

4.0 VFFS1-2037PM 142 170 150 2.1

5.5 VFFS1-2055PM 180 220 170 4.3

7.5 VFFS1-2075PM 180 220 170 4.3

11 VFFS1-2110PM 245 310 190 8.6

15 VFFS1-2150PM 245 310 190 8.6

18.5 VFFS1-2185PM 245 310 190 8.9

22 VFFS1-2220PM 240 420 214 16.4

30 VFFS1-2300PM 320 630 290 38.7

0.4 VFFS1-4004PL 107 130 150 1.4

0.75 VFFS1-4007PL 107 130 150 1.4

1.5 VFFS1-4015PL 107 130 150 1.4

2.2 VFFS1-4022PL 107 130 150 1.4

4.0 VFFS1-4037PL 142 170 150 2.4

5.5 VFFS1-4055PL 142 170 150 2.4

7.5 VFFS1-4075PL 180 220 170 4.7

11 VFFS1-4110PL 180 220 170 4.7

15 VFFS1-4150PL 245 310 190 9.0

18.5 VFFS1-4185PL 245 310 190 9.0

22 VFFS1-4220PL 240 420 214 15.4

30 VFFS1-4300PL 240 420 214 15.4

37 VFFS1-4370PL 240 550 214 23.5

45 VFFS1-4450PL 240 550 214 23.5

55 VFFS1-4550PL 320 630 290 40

75 VFFS1-4750PL 320 630 290 40

■Standard connection diagram : Sink logic(common : cc)

Main circuit power supply 200V class : three-phase 200-240V -50/60Hz 400V class : three-phase 380-480V -50/60Hz

Applicable motor(kW)

Input voltage Class

Approximate weight(kg)

3-phase 200V (IP20/IP00)

3-phase 400V (IP20/IP00)

Dimensions(mm)

Width Height Depth

Inverter type

0.75 VFFS1-4007PL1E 5.3

VFFS1-4007PDE 5.6

1.5 VFFS1-4015PL1E 215 297 192.3

5.3

VFFS1-4015PDE 5.6

2.2 VFFS1-4022PL1E 5.3

VFFS1-4022PDE 5.6

3.7 VFFS1-4037PL1E 7.2

VFFS1-4037PDE 8.1

5.5 VFFS1-4055PLE 7.2

VFFS1-4055PDE 230

340

208.3

8.1

7.5 VFFS1-4075PLE 8.5

VFFS1-4075PDE 9.4

11 VFFS1-4110PLE 21.0

VFFS1-4110PDE 25.5

15 VFFS1-4150PLE 295.3 560 292.9

21.0

VFFS1-4150PDE 25.5

18.5 VFFS1-4185PLE 28.5

VFFS1-4185PDE 315 665 293.4

33.5

22 VFFS1-4220PLE 29.0

VFFS1-4220PDE 33.5

30 VFFS1-4300PLE 285 720 289.4

29.0

VFFS1-4300PDE 33.5

37 VFFS1-4370PLE 38.1

VFFS1-4370PDE 43.5

45 VFFS1-4450PLE 285 880 334

38.1

VFFS1-4450PDE 43.5

55 VFFS1-4550PLE 58.0

VFFS1-4550PDE 69.1

75 VFFS1-4750PLE 362 1000 354

58.0

VFFS1-4750PDE 69.1

Applicable motor(kW)

Input voltage Class

Approximate weight(kg)

3-phase 400V (IP54)

Dimensions(mm)

Width Height Depth

■Standard specificationsItem Specification

Applicable motor (kW) 0.4 0.75 1.5 2.2 4.0 5.5 7.5 11 15 18.5 22 30 37 45 55 75 Input voltage class  Type VFFS1 3-phase 200V class   VFFS1- 2004PM 2007PM 2015PM 2022PM 2037PM 2055PM 2075PM 2110PM 2150PM 2185PM  2220PM 2300PM   - - - - 3-phase 400V class(IP20/IP00) VFFS1- 3-phase 400V class

VFFS1-

(IP54) Capacity (kVA) 200V class/400V class Output current (A) 3-phase 200V class 3-phase 400V class

Type Form

Rating

Power supply

Note3) 400V class(IP54):-10 to 50℃(Current decrease when over 40℃)

Note2) The rated output current is at default setting of PWM carrier frequency( ).15kW or less : 12kHz, 18.5kW or more : 8kHz. The rated output current in the parenthesis is at 12kHz of PWM carrier frequency( )setting.

Note1) Refer to “Built-in filter” for difference between PLE/PL1E type and PDE type.

FLA

PLC PLC

FM CC VIA VIB PP

FLB

FLC

MCCB R/L1S/L2T/L3

U/T1Motor

V/T2W/T3

RY

P24

RC

PA/+

Noise filter Power circuit

Control circuit

Operation panel

Connector for RS485(2wire) communications

SW4 SOURCE

SINK

FM VIA

SW2 SW3

V I

V I

PC/-

IM

VF-FS1Protective function activation output

Low-speed signal output

24Vdc input

Meter

7.5V-1mA (or 4-20mA)

Voltage signal : 0-10V (Current signal : 4-20mA)

External potentiometer(1-10kΩ) (or input voltage signal across VIB-CC terminal : 0-10V)

F

R

RES

CC

Forward

Reverse

ResetCommon

Frequency meter

(ammeter)

PLC

SOURCE

SINK

CC

P24

F

R

RES

Forward

Reverse

Reset

Note2)

Note1)

200V class: 200V to 240V - 50/60Hz, 400V class: 3-phase 380 to 480V - 50/60Hz Voltage +10%, -15% (±10% when the inverter is used continuously (load of 100%)),Flequency ±5%

Voltage/frequency Allowable fluctuation Output voltage adjustment Adjustable within a range of the corrected supply voltage 50 to 660V (Unadjustable to any voltage higher than the input voltage). Output frequency range 0.5 to 200.0Hz (default setting 0.5 to 80.0Hz)  Voltage/frequency characteristics V/f constant, variable torque, automatic torque boost, vector control, automatic energy conservation, PM motor control, auto-tuning function Overload current rating 60 seconds at 110%, 2 seconds at 180% Main functions Wizard, Local/Remote change-over, Bumpless operation, Forced fire-speed control, PTC thermal protection, Programmable I/O terminal block, Auto-restart Ambient temperature/Relative humidity -10 to 60℃ (Current decrease when over 40℃) Note3) /5 to 95% free from condensation and vapor

Protective method

Cooling method Forced air cooling(PL1E type:self-cooling)

Built-in filter PM type:Basic noise filter. PL,PL1E,PLE(5.5,7.5kW):EMI filter (EN61800-3 1st Environment C2 or 2nd Environment C3),

PLE(11kW or more) type:EMI filter (EN61800-3 2nd Environment C3). PDE type:EMI filter (EN61800-3 1st Environment C1)

PM,PL type:IP20(0.4 to 18.5kW), IP00(22kW or more) PLE,PL1E,PDE type:IP54

4004PL 4007PL 4015PL 4022PL 4037PL 4055PL 4075PL 4110PL 4150PL 4185PL 4220PL 4300PL 4370PL 4450PL 4550PL 4750PL4007PL1E 4015PL1E 4022PL1E 4037PL1E 4055PLE 4075PLE 4110PLE 4150PLE 4185PLE 4220PLE 4300PLE 4370PLE 4450PLE 4550PLE 4750PLE4007PDE 4015PDE 4022PDE 4037PDE 4055PDE 4075PDE 4110PDE 4150PDE 4185PDE 4220PDE 4300PDE 4370PDE 4450PDE 4550PDE 4750PDE

1.1 1.8/1.6 2.9/2.8 4.0/3.9 6.7/6.9 9.2/9.1 12.2 17.6/17.1 23.2 28.5/28.2 33.5/33.2 44.6 -/60.2 -/71.6 -/88.4 -/121.92.8 4.6 7.5 10.6 17.5 24.2 32 46.2 61 74.8(67.3) 88(79.2) 117.0(105.3) - - - - 1.4 2.2 3.7 5.1 9.1 12 16 22.5 30.5 37(33.3) 43.5(39.2) 58.5(52.7) 79.0(71.1) 94.0(84.6) 116.0(104.4)160.0(128.0)

3-phase 200V class(IP20/IP00)0.4kW to 30kW

3-phase 400V class(IP20/IP00)0.4kW to 75kW

3-phase 400V class(IP54) 0.75kW to 75kW

TOSVERT™ inverter dedicated to fan and pump for HVAC

This product is designed and manufactured in factories that have acquired certification of “ISO-9001”, the international quality assurance standard.

The factories manufacturing this product are ISO-14001, environmental management system, registered factories.

ISO-9001 Certification Acquired ISO-14001 Certification Acquired

International Operations 9-11, Nihonbashi-honcho 4-chome, Chuo-ku, Tokyo 103-0023, Japan Tel : +81-(0)3-5644-5509 Fax : +81-(0)3-5644-5519

TOSHIBA INDUSTRIAL PRODUCTSSALES CORPORATION

AB08-02 (AB)8697A

Totally enclosed box type for IP54

3-phase 200V class ( IP20/IP00 )

3-phase 400V class ( IP20/IP00 )

3-phase 400V class ( IP54 )

Voltage class

Applicable Motor Output (kW)

0.4 0.75 1.5 2.2 4.0 5.5 7.5 11 15 18.5 22 30

SPACE SAVING, ECO-FRIENDLY, NOISE-LESS and LONG LIFE

The VF-FS1 provides these features as standard.

DREAM INVERTER dedicated to fan and pump for HVAC

Half installation space and less wiring

 Reactor-less harmonic suppress technologies and built-in filterNote1) reduce 50%Note2) of installation space, save time and cost of wiring.

Note1) 400V class models, EMI noise filter built-in as standard model (European EMC Directive, IEC/EN618000-3, 1st Environment, C2 or IEC/EN61800-3, 2nd Environment, C3)

200V class models, Basic noise filter built-in as standard model

Note2) IP20/IP00 models

・ 15 years life designed main capacitors Note1)

・ An alarm warns when the main circuit capacitors, circuit boards capacitors, or cooling fan needs to be replaced.・ Cooling fan's On/Off control extend its life・ Easy replacement cooling fan by one touch Note2)

・ The inverter unit can be replaced by removable terminal block without disconnecting cables.

Note1) Ambient temperature:annual average 35℃,output current:80% of rated current, 24hour operation 365days per year.

Note2) 18.5kW or less are possible to replacement by one touch, 22kW or more are screw type.

Ideal functions are built-in for fan and pump application.

・ The local or remote operation can be selected by one touch

・ Bumpless function realize seamless operation between local and remote

・ Fire control enables forced operation in emergency

・ Speed reference can manage on/off operation (Sleep function)

・ Low current detection can notice a broken belt or low load for pump application

・ PTC thermistor input

・ Include RS485 (TOSHIBA/Modbus protocol) communication as standard Optional filed buses for LonWorks®, BACnet®, Metasys®N2 and APOGEE® FLN as built in option.

The advanced energy-saving mode optimizes fan and pump efficiency even at normally inefficient in low speeds.The effect can be monitored by operation panel or through serial communication data.A wizard function enable set the 10 most often used parameter quickly.

Toshiba unique technologies suppress harmonics, particularly 5th and 7th harmonic current that affect power sources.And the power factor in all models has been improved. Harmonics are controlled to within the Total Harmonic Distortion (THD) of international standard IEC61000-3-12 without any external reactor.(Rsce ≧120)

Quick setting wizard Effect of advanced energy-saving mode

Long-life main circuit film capacitor

Relative harmonic content

Relative harmonic content(%)

Order

100.0%

90.0%

80.0%

70.0%

60.0%

50.0%

40.0%

30.0%

20.0%

10.0%

0.0% 1 2 3 4 5 6 7 8 9 10 11

Existing modelExisting model with DC reactorVFFS1

When a TOSHIBA standard 3-phase, 200V-7.5kW- 4 pole motor and test fan are driven.

Input/output current comparison12

10

8

6

4

2

00 10 20 30

Output frequency(Hz)

Current(A)

40 50 60

Input current of existing model

Input current of VFFS1

Output current of existing model

Output current of VFFS1

The input current decreases 20%

When a TOSHIBA standard 3-phase, 400V-7.5kW- 4 pole motor and test fan are driven.

Title Function Automatic acceleration/deceleration Acceleration time 1 Deceleration time 1 Lower limit frequency Upper limit frequency Motor thermal protection Meter adjustment V/F control mode selection Base frequency 1 Base frequency voltage 1

Existing model VF-FS1

DC reactor

Noise filter

Removable control terminal

LonWorks® network circuit boardLocal/Remote key

P O I N T3

Reactor-less harmonic reduction

Long life and easy maintenance

Special softwares for fan and pump application are built-in

More energy saving and easier operation

Cooling fan

120

100

80

60

40

20

010 20 30 40 50 60 70 80 90 100

The effect of energy savingThe effect of energy saving

Damper control

V/F control

Advanced energy saving

Applications:

・ AHUs・ Ventilation fans・ Chillers・ Water pumps

etc.

P O I N T4

P O I N T5

P O I N T1

P O I N T2

TOSVERT™ inverter dedicated to fan and pump for HVAC

Comparison of mounting space against Existing model

About 50%Inverter

Note : VF-FS1 is not applicable for apparatus which needs sudden deceleration and stop.

Totally enclosed box type for IP54

Compatible with the World’s Main Standards (CE marking, UL, CSA, C-tick)

Approvalpending

37 45 55 75