treatability study of mixed waste using ion exchange resins ilham almahamid brian m. smith lawrence...
TRANSCRIPT
Treatability Study of Mixed Waste Using Ion Exchange Resins
Ilham AlMahamid
Brian M. Smith
Lawrence Berkeley National Laboratory
EIChroM Users’ Group Workshop, Pleasanton, CA, May 25, 1999
Experimental Objective
By employing innovative treatment technology, meet Land Disposal Restriction waste treatment standards and provide a disposal option for 105 gallons of mixed waste generated by neutralization and consolidation of corrosive mixed wastes from past LBNL research.
Waste Description
Multiphase (solid, organic and aqueous) Presence of regulated metals such as chromium, lead
and mercury at concentrations that render the waste “combustion prohibited”.
Presence of regulated solvents such as chloroform, acetone, and methylene chloride that make combustion the appropriate treatment method.
Experimental Approach
Conduct a treatability study to reduce the concentrations of regulated metals to levels that would remove any combustion prohibition.
Chromium 2.77 mg/L Note: Chromium target in
Mercury 0.15 mg/L R12 is 1,350 mg/L because Lead 0.69 mg/L only half of the 2,700
mg/L
Silver 0.43 mg/L is combustion prohibited.
METHODS
Separate the organic layer (scrape off top)
Separate the sludge (vacuum filtration)
Treat the aqueous phase (resin exchange)
Treatment of the Aqueous Phase
Literature review of resins used to remove actinides and heavy metals from wastes
Diphonix, Radaway, and apatite were selected for further testing
Bench-Scale Studies
Diphonix resin, Radaway slurry, and apatite were added to aliquots of the waste.
Resin to waste ratio was 5 g / 50 mL. Vials were placed on a shaking table (100 rpm) for 24
hours at room temperature. Solutions were filtered and analyzed for actinides and
metals.
Diphonix had high uptake and was easy to handle.
Treatment of R12
Chromium (2,700 mg/L) was determined to be in two forms: Cr(III) and Cr(VI) as chromate from chromic acid
Precipitate chromate by addition of BaCl2. Reduced Cr concentration to ~400 mg/Liter Solution turned from orange to very light yellow. Filtered to remove solids (barium chromate+ barium sulfate).
Passage through the ion-exchange columns.
Semi-Pilot Scale Treatment
The set-up consists of:
– peristaltic pump– on-line filter– series of six columns, three containing diphonix resin
(cationic exchanger) and three containing anionic exchanger.
Results
R12 R13 R213 passes 1 pass 2 passes
Chromium 98.3% 96.0% 37.5%Mercury 99.6% >99.9% 99.9%Lead >50% >87.5% >50%Silver >89.2% >87.5% n.d.
Am-241 86.7% 95.0% 97.4%Np-237 98.9% 99.6% 99.5%Pa-233 98.8% 99.5% 99.2%Pu-239 82.6% n.d. n.d.
Metal and Actinide Removal
Results (continued)
R12 R13 R213 passes 1 pass 2 passes
Antimony 97.5%Copper 93.0% >83%Molybdenum 94.0%Nickel 25.0%Thallium 92.9%Zinc 88.9% 78.0%
Removal of other Metals
Conclusions
The treatment study removed regulated metals to allow combustion as a disposal option for 105 gallons of aqueous mixed waste.
Diphonix is useful in removal of metals and
actinides from aqueous radioactive wastes.
Small amounts of organics such as acetone did not diminish the efficiency of the resin.