Page 1: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

1

CHIEF ELECTRICAL ENGINEER. BILASPUR.

CHIEF ELECTRICAL ENGINEER. BILASPUR.

CHIEF ELECTRICAL ENGINEER BILASPUR

TROUBLE SHOOTING DIRECTORY

FORAC LOCOMOTIVES

ELECTRIC LOCO TRAINING CENTRE.USLAPUR. S.E.C.RAILWAY

Page 2: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

2

ELECTRIC LOCO TRAINING CENTRE.

The present edition of TROUBLESHOOTING Directory is prepared in such a wayto make it user-friendly and also to educate the user, on theoretical background ofproblems and solutions. On opening the first page itself the user will know what torefer, to overcome the problem encountered by him. To minimize the time to reachrelevant Chapter/page, the facility of Index Cutting is provided. The explanatorynotes along with the appropriate circuits are given on the left side of theproblems/failures discussed on the right side. This is done so as to educate theDriver on the theoretical background of problems and solutions there off. Though,the TROUBLESHOOTING DIRECTORY is referred by the LOCO PILOTgenerally in case of failure only, the explanatory notes given can be gone through bythe driver in his spare time. Over a period of time, this will enable the LOCOPILOT to become sufficiently familiar with the theoretical aspect of a failure,making him competent to troubleshoot the failure without having to referTROUBLE SHOOTING DIRECTORY at the instant of the failure.

The air brake system is being introduced both in coaching and freight stockon large scale. The problems/failures connected with air brake system are dealt withexclusively and in detail. In addition to the TROUBLESHOOTING, this bookconsists of Operating Instructions and Operation of Multiple Units,problems/failures regarding air brake trains and other instructions.

We sincerely hope that the LOCO PILOTS community will make the best use of theend product of the efforts put in by all of us.

Sri P.N.Khatri Date: ……………Principal. USLAPUR.ELTC/USL.

Page 3: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

3

DEAR LOCO PILOT.

1. BE ENERGY CONSCIOUS.

2. CONTACT THE LOCOMOTIVE CONTROLLER WITHIN 30 MINUTESFOR ASSISTANCE.

3. CHECK BRAKE POWER OF LOCO/TRAIN AT FIRST OPPORTUNITY.

4. DO NOT LEAVE LOCO UN-MANNED

5. DO NOT CARRY ANY UNAUTHORISED PERSON.

6. IN MU/CONSIST DURING FAILURE:IF LOAD PERMITS, CLEAR BLOCK SECTION WITH GOOD LOCO.WITHOUT WASTING TIME FOR TROUBLE SHOOTING.

7. IN CASE OF ANY TROUBLE IN LOCO:RECORD OHE VOLTAGE, SPEED, NOTCH, CURRENT ANDKILOMENTER ETC.

8. DO NOT DRIVE THE LOCO ON TRACK SUBMERGED BY 6” ORMORE WATER.

9. TAKE ADVANTAGE OF COASTING.

10. WHILE WORKING GOODS TRAIN:DRAW THE TRAIN UP TO THE FOOT OF THE STARTER.

Page 4: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

4

CONTENTS

Sr.No Subject Page No.

1 Standard instructions for the Drivers

2Difference Between WAG5, WAM4 (6P) and WAG7

3 Difference Between WAP-1 & WAP-4 LOCOS

4TSD forWAG5, WAG7, WAM4(6P), WAP1 and WAP4 class locos

5 TSD for Static Converter Loco.

6 TSD for Microprocessor Loco.

7 ANNEXURE-A(VCD & its trouble shooting)

8ANNEXURE-B(Working with leading loco in MU/Consist,

when leading loco is defective to clear block section only

9ANNEXURE-C(Nomenclature of Relays, HMCS position,

Cantilever Assembly, Technical details)

Page 5: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

5

STANDARD INSTRUCTIONS FOR LOCO PILOT AND LC.

1. During trouble shooting in block section, utmost care should be taken to trouble shootthe fault, and resume traction within 20 minutes. If unsuccessful LC/TPC control is tobe informed, for assistance. All efforts should be made to minimize and curtaildetentions in block section.

2. In MU/Consist, if one of the loco fails, try to clear block section, with good loco orgood locos without wasting time for trouble shooting.

3. In case of trouble shooting in MU/Consist locos, the abnormal sign should always bepicked up from leading loco. There after all the observations and interventions shall bemade on the loco which is defective.

4. When ever HOBA is placed in OFF position during trouble shooting in one of the locoin MU/Consist, HOBA of other locos also to be kept in OFF position.

5. While wedging contactors or relays ensure that the auxiliary contacts are fully operatedand contactors do not chatter after wedging.

6. LC should be informed at the normal stoppage regarding wedging of relays/contactors.

a) FOR WEDGING CONTACTORS – Take Complete Safety measures.If C105, C106 & C107 are wedged; Q118 isto be manually operated for closing DJ.After isolating any auxiliary motor throughrotating switch, ensure its correspondingcontactor is properly opened.

b) FOR WEDGING RELAYS - First switch off battery.If relay Q118 is wedged – block sectionmay be cleared observing working of allAuxiliaries.

7.a) During trouble shooting if MPH is isolated, the train can be worked up to thedestination provided MVRH is working normally and there is no appreciable rise in theoil level in the transformer gauge.

The following current rating to be observed.

Starting: 920 amps for 10 minutes.Continuous: 500 amps.

Page 6: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

6

The loco should be withdrawn in a planned manner by the LC.

b) In case MVRH is isolated – Put HC105 on ‘0’,if HC105 is not provided Wedge Q118,clear block section with the following current rating.

Starting: 920 amps for 10 minutes.Continuous 500 amps.

c) In case MVSL is isolated – Clear block section with the current rating of 500 Amps.

8. During trouble shooting if HOBA/HQOP is kept OFF or HQOA is on 0, a frequentwatch should be kept for any smoke emission from power equipments i.e. RSI blocks,TMs, BA panel and auxiliaries etc. as the case may be. LC should be informed beforestarting the train. LC should withdraw the loco with HQOP/HOBA in off or HQOA on 0in a planned manner and direct the loco to the nearest shed for attention.

9. Whenever any equipment (including TM)/relay are isolated on a locomotive, loco pilotmust record in the loco log book and inform LC at the first available opportunity.LC mustensure planned withdrawal of the loco from service.

10. Driver must record all cases of on line loco troubles/other unusual occurrences/ wheelslipping, clearly mentioning the time loss in block section/station, time and place ofoccurrence as well as information given to LC.11. Whenever HPAR is placed in “0” position during trouble shooting in one of the locoin MU/Consist, HPAR of other locos also to be kept in “0” position.

12. Check availability/working of following safety equipments.

1. Flasher light/Marker light/Head light.2. Portable telephone/Fire extinguisher/detonators/wooden wedge etc..

Page 7: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

7

DIFFERENCE BETWEEN WAG5, WAM4 (6P) AND WAG7

Sr.No

DESCTRIPTION WAG-5 WAM4 (6P) WAG7

1. Transformer 3900 KVA HETT 3900 KVA HETT 5400 KVA HETT

2. Traction Power Ckt. 6TMs 6TMs 6 TMs3. TM TYPE a) TAO 770 HP a) TAO 770 HP Hitachi 845 HP

4. Current RatingsContinuous

1000A/30S 750A/650 V

1000A/30S750 A/650 V

1350A/30S 900A/750 V

5. Rheostat Braking 650 A - 325 V 650 A - 325 V(ifavailable)

650 A - 325 V

6. Line Contactors 6Nos. (L1-L6) 6Nos. (L1-L6)6Nos.(L-1N-L6N)(available insome locos)

6NOS. {L1-L6}

7. SL/MVSL 2 Nos. [MVSL] [SL] 2 Nos. [MVSL][SL]

2 Nos. {MVSL}{SL}

8. REVERSERS 2 Nos.J1 forTM1,2,3J2 for TM 4, 5, 6

2 Nos.J1 forTM1,2,3J2 for TM 4, 5, 6

2 Nos.J1 forTM1,2, 3J2 for TM 4, 5, 6

9. HMCS (TM SelectionSwitch)

2 Nos.HMCS1/TM1.2, 3HMCS2/TM 4, 5, 6

2 Nos.HMCS1/TM1.2, 3HMCS2/TM4,5,6

2 Nos.HMCS1/TM 1,2,3HMCS2/TM 4,5,6

10. QOP (Earth FaultProtection Relay

2 Nos.QOPI/SL1.RSI1J1,TM1,2, 3QOP2/SL2, RSI2 J2,TM 4, 5, 6

2 Nos. 2 Nos.

11. HQOP 2 Nos.HQOP1/SL1.RSI1 J1&TM1.2&3HQOP2/SL2, RSI-2, J2TM 4, 5 & 6

2 Nos. 2 Nos.

12.

SHUNTS 3 Nos. in loco 23385onwards

2 Nos. 3 Nos.

13 BRAKES(Mechanical)

Dual Brake systema) IAB and hand brakefor loco.b) Vaccuum. Brake forvaccuum. stock.c) Air brake for Airstock.

a) IAB and handbrake for loco.b) Air brake for Airstock.

a) IAB and handbrake for loco.b) Vac. Brake forvac.stock.

14. WEIGHT 120 T 113.2 T 123T

Page 8: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

8

15. TRACTIVE EFFORT 35.6 T (max) 30 Tused.

30.8 T18.8 T(Continuous)at 72 kmph

42 T

16. QD(Differential relay)Locos up to 23384

Locos beyond 23385

2 Nos.

QD-1 for TM1&3QD-2 for TM4&6QD-1 for TM2&3QD-2 for TM4&5

2 Nos.QD-1 for TM2&3QD-2 for TM4&5

2 Nos

QD-1 for TM2&3QD-2 for TM4&5

17 Main compressors(MCP)

3 Nos. (MCP1,MCP2& MCP3)

3 Nos. (MCP1,MCP2 & MCP3)

3 Nos. (MCP1,MCP2& MCP3)

DIFFERENCE BETWEEN, WAP-1 & WAP-4 LOCOS

Sr.No

DESCTRIPTION WAP-1 WAP-4

1. Transformer 3900 KVA HETT 5400 KVA CGTT2. Traction Power Ckt. 6TMs 6 TMs3. TM TYPE Hitachi 8445 HP HS 15250 A4. Current Ratings Continuous 1350A/30s

900A/750V990A/1 HR900 A/750 V

5. Rheostat Braking 650 A - 325 V Nil6. Line Contactors 6Nos. (L1-L6) 6NOS. {L1-L6}7. SL/MVSL 2 No. [MVSL] [SL] 2 Nos. {MVSL} SL 308. REVERSERS 2 Nos.

J1 forTM1,4, 2J2 for TM 3, 6, 5

2 Nos.J1 forTM1,2, 3J2 for TM 4, 5, 6

9. HMCS (TM Selection Switch) 2 Nos.HMCS1/TM1.2, 3HMCS2/TM4,5,6

2 Nos.HMCS1/TM1.2, 3HMCS2/TM4,5,6

10. QOP (Earth Fault Protection Relay) 2 Nos. 2 Nos.11. HQOP 2 Nos.

HQOP1/SL1.RSI1 J1&TM1.2&3HQOP2/SL2, RSI-2, J2TM 4, 5 & 6

2 Nos.

12.

SHUNTS 3 Nos. 4 Nos.

13 BRAKES(Mechanical)

a) IAB and hand brake forloco.b) Air brake for Air stock.

a) IAB and hand brake forloco.b) Air brake for Air stock.

Page 9: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

9

14. WEIGHT 108.3 T 112.8 T15. TRACTIVE EFFORT 32.49 T 30.8 T

18.8 T (Cont) at 72 kmph16. QD (Differential relay) 2 Nos.

QD-1 for TM2&3QD-2 for TM4&5

2 Nos.QD-1 for TM2&3QD-2 for TM4&5

17 Main compressors (MCP) 3 Nos. (MCP1, MCP2 &MCP3)

2 Nos. (MCP1 & MCP2)

Page 10: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

10

TROUBLE SHOOTING DIRECTORY

FOR WAG5, WAG7, WAM4(6P), WAP1 AND WAP4 CLASS LOCOS

Sr.No Contents PageNo

1

CHAPTER- ONEChecking operation of tripping failures & trouble shooting of redtarget dropped relays

2 CHAPTER- TWOTripping failure

3

CHAPTER-THREETraction failure, Precautions on relay wedging

4CHAPTER FOUR1. Miscellaneous failures.2.DRUM contactors in pictorial view with operation

5

CHAPTER FIVE1.Trouble Shooting for Static converter loco2. Trouble Shooting for Microprocessor loco3. ANNEXURE-A(VCD & its trouble shooting)4. ANNEXURE-B(Working with leading loco in MU/Consist,when leading loco is defective to clear block section only5.ANNEXURE-C(Nomenclature of Relays, HMCS position,Cantilever Assembly, Technical details)

Page 11: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

11

TROUBLE SHOOTING DIRECTORY FORWAG5/WAG7/WAM4 (6P)/WAP1/WAP4 LOCOS

CHAPTER ICHECKING OPERATION IN CASE OF TRIPPING FAILURES

Preparation-1

Tripping on line, Bring back MP to 'O'. Wait 15 second for LSGR to glow. Checkpanto if found any abnormality do accordingly Refer Page No. -------. Check the relaytargets by physically operating reset button of each safety relay. If any relay targetshows red indication refer the page number as follows.Srl Abnormal sign TSDNo. PageNo.

1. QLM tripped alone 00

2. QLM along with QRSI-1 &2 00Or

QLM along with QRSI-1&2 and QOPOr

QOP along with QRSI-1&2

3. QLA tripped 00

4. QOA tripped 00

5. QOP-1 or QOP-2 alone tripped 00

6. QRSI-1 & QRSI-2 alone tripped 00

TROUBLE SHOOTING OF RED TARGET DROPPED RELAYSProbable defects Action to be taken by the Driverobservation/checking1.IF QLM HAS TRIPPED DO NOT RESET RELAY TARGET.ALONE Check for oil splashing near tap

changer, GR safety valve blowing off,CGR contractors, proper fitment of arc-chute. Roof bushing insulators, GR andTFP oil level.Request for assistance / Relief loco.

Page 12: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

12

2. QLM ALONGWITH Check corresponding CKT.Check RSI block,J-1,J-2,CTF-1,2,3,Line contactors, shuntingcontactors,SJ coils, traction motors, if noabnormality noticed then

QRSI-1 or QRSI-2 i. Reset the relay indicators — ResumeOR traction.

QLM ALONG WITH If DJ trips again — through the same relays,QRSI-1, QOP1 Put HMCS on position II, III & IV one by one.

OR Resume traction.QRSI-2 & QOP2 Observe the above relays dropping

OR Put HMCS in that positionQRSI-1, QRSI-2 ALONG where tripping does not occur, Reset relayWITH QOP target. Close DJ. Resume traction.

ii. If tripping again takes placein all position of HMCS.Put back HMCS on position-1.Put HQOP-1/HQOP-2 in 'off' position.Resume traction.iii. If tripping takes place again.Reset the realy indicators.Once again try with HMCS on differentpositions one by one.Observe the target of above relays.Keep HMCS in that position where trippingdoes not take place. Resume traction.Observe for any smoke emission on run.iv. If tripping takes place again in allpositions of HMCS. Isolate corresponding RSIblock. (Rectifier block). If MVMT-1 is isolated,wedge C 106 (if required in non-modifiedblower circuit), Manually operate Q118. If loadpermits — Resume traction. If load does notpermit — contact LC.

CAUTION

DO NOT PUT HQOP/HOBA IN ‘OFF’ POSITION UNLESS TRACTION MOTOR-

ISOLATION IS TRIED THROUGH OPERATION OF HMCS.

Page 13: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

13

To reset Mechanical QLM

To reset Other Relays

Procedure of resetting the Relay provided with Red Target

Page 14: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

14

Probable defects Action to be taken by the Driverobservation/checking3. IF QLA HAS TRRIPED Check for smoke omission from auxiliary

motors,contactor panel, ARNO and R118 & C118.If no abnormality — Reset the relay indicator.Close DJ. Resume traction.If DJ trips again through QLA.Check for smoke emission.If no smoke emission — Reset the relay target,close DJ.Resume traction.

4.QOA TRIPPED Check for smoke emission from auxiliary motorscontactor panel, ARNO & R118 cabfan,TFVT,cab heater,CHBA,RTPR. Ensure allcontactors are open.a. If no abnormality, reset the relay indicator.Close DJ and Resume traction,i. If DJ trips through QOA again, openBLRA1/BLRA2switches. Remove CCRA1 & CCRA2 fuses.Change the position of ZPV, HCP/ZCP.Re-set Relay Target. Close DJ — ResumeTraction,ii. If DJ trips again through QOA, put HQOAon ‘0’ & close DJ,if successful work the trainobserving all auxiliaries for smoke emissionson runb. If unable to reset the relay indicator.i. Put HQOA on "O". Reset the relay indicator.Close DJ and resume traction.Observe for any smoke emission on run.Close DJ and resume traction.Observe for any smoke emission on run.c. If there is smoke emission from anyauxiliary motor, extinguish fire using fireextinguisher. Follow the instruction givenbelow —

Page 15: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

15

Probable Defects/ Action to be taken by the Driver.observation/ checkingMPH Put HPH on "0". Ensure MVRH is working,

Continue Traction not exceed the followingratings :920 Amps for 10 minutes500 Amps continuous.Check TFP oil level frequently

MVRH Put HVRH on 'O'.& HC105 ON ‘0’ ,If not providedwedge Q118.Clear block section. Maintain thefollowing current ratings — 920 Amps for 10minutes.

MVSI-I PuttheHVSI-1, HVMT-1 andHVSL-1or on'O. Wedge C106

(if required).MVMT-I

orMVSL-I

orMVSI-2. Put HVSL2, HVMT-2 and HVSI-2

or on 'O'.MVMT-2

orMVSL-2

MCP-1orMCP-2orMCP-3or Isolate the defective auxiliary and use the good

one. Resume tractionMPV-1orMPV-2.

.

.

Page 16: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

16

NOTE: AFTER ISOLATING ANY AUXILIARY MOTOR, ENSURE THECORRESPONDING CONTACTOR IS IN OPEN CONDITION AND ENTER IN ELOCO LOGBOOK, INFORM LC.

Probable Defects/ Action to be taken by the Driver.observation/ checking5.QOP-I OR QOP-2 Check for Smoke Emission from TMs,ALONE HAS TRIPPED Reversers, CTFs, RSI blocks, line contactors

and SLs.If there is smoke emission — Use fireextinguisher to extinguish fire.Isolate the equipment — Resume traction.If there is no smoke emission.Relay indicator can be reset:— Resume traction.

If DJ trips again — Through the same relay.Put the corresponding HMCS on position II, III,IV one by one. Reset the relay — Resumetraction. Observe QOP dropping.Keep HMCS in that position, where QOP is notdropping. Resume traction.

IF QOP 1/QOP 2 AGAIN DROPS If QOP-1/QOP-2 drops in all positions of HMCS.Put HQOP-1/2 in 'OFF' position. Keep backHMCS on position 1 — Resume traction.Observing for any smoke emission on run.Isolate corresponding block, Observe for anysmoke emission on run.

b. If relay indicator cannot be reset.i. Put HQOP-1/HQOP-2 in 'OFF'.Reset the relay target — Resume traction.Observe for any smoke emission on run.ii. If still unable to reset the relay :-Put HOBA in ‘off’ condition & reset the relay— Resume traction.

6. QRSI1/QRSI-2 ALONE HAS TRIPPED. (A). Reset the relay indicator.Note down the Ammeter readingResume traction at lower notches.(B).If unsuccessful:Isolate Traction Motor one by onecorresponding to QRSI dropped. Resumetraction.(C)If unsuccessful againisolate corresponding RSI (Rectifier)block.

Page 17: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

17

Put HVSI-1/HVSI-2, HVSL1/HVSL-2 andHVMT-1/ HVMT-2 on 'O'. correspondinglyIf load permits — Resume traction.If load does not permits — Inform LC.

CAUTION

1. DO NOT PUT HQOP IN "OFF" POSITION UNLESS TRACTION MOTOR-ISOLATIONIS TRIED THROUGH OPERATION OF HMCS.2. ISOLATE TM THROUGH HMCS IN CASE OF REVERSOR CONTACT MELTED, ITLEADS TO BE FLASH OVER/FIRE

Page 18: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

18

CHAPTER-II(Tripping failure)

If no relay target shows red indication, to pick up abnormal sign do as given below.

Preparation-2Ensure MP on “0”, MPJ on “0”& LSGR glows. Open all auxiliary switches except

BLCP”A”.Close BLDJ, Press BLRDJ and observe LSDJ, UA needle & LSCHBA to pickup “8” abnormal signs as follows :-

Srl TSD LocoNo. PageNo. defect Abnormal sign Probable failures

1. ICDJ LSDJ remains glowing MR/RS pressure, BAvoltageCCBA, CCPT, CCDJ, Q44Q45, Q118, C118

2. No tension on line LSDJ goes out but UA OHE supply, Panto, Roofneedle does bar & foreign body onnot deviate loco roof

3. OPERATION-A LSDJ goes out, UA needleDeviates, but LSDJ glowsAgain before LSCHBA ARNO, QCVARGoes out

4. OPERATION-B LSDJ & LSCHBA goes MPH/QPH,Out, but LSCHBA comes MVSL-1/QVSL-1Again within 15 seconds MVSL-2/QVSL-2after LSCHBA goes out. NOI of QCVAR on Q118 Br.

NOI of Q30 on Q44 Br.

5. OPERATION-O LSDJ & LSCHBA goes MVMT-1/QVMT-1Out, Ensure MR pressure MVMT-2/QVMT-2is more than 8.0 kg/cm2 MVRH/QVRHclose BLVMT, wait 15seconds .And LSDJ glows

Page 19: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

19

6. OPERATION-1 Take one traction MVSI-1/QVSI-1,Notch. And wait MVSI-2/QVSI-2If LSDJ glows Q 44 or SMGRwithin15sec.

7. OPERATION-2 LSDJ glows within C105,C106&C10715 sec. after taking not closing or defect in6 notches their interlocks(Follow as per thecase below)

Case-1While standing:-

Open DJ,Put both HVSI 1&2 switch on “0”.Close DJ,take 6 traction notches andwait “15” seconds.if LSDJ glows.

Case-2While on Run:-

Take 6 traction notches and wait “15” seconds. If LSDJ glows –OP-II.

8. 41 TWACDJ trips repeatedly either after checking of OP.-1 in between 2nd to 5th notch or

after checking OP-2 in between 7th to 32nd notch

CHECK PANTO FIRST AND THE RELAY TARGETS AFTER EVERY TRIPPING

Page 20: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

20

ICDJ

(LSDJ REMAINS GLOWING [Re-Check relay target, if dropped trouble shoot as perpage No. __)Remarks -1 For SURemarks - 2 For MU/consists-Refer page No 00

Probable defects/observation/checking Action to be taken by the Driver.

REMARK-IEnsure BLDJ is closed, LSGR glowing

Page 21: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

21

and ZPT is in other than 'O' position.Check MR pressure and RS pressure. CheckBPEMS in both cab.

1. MR & RS PRESSURE IS LESS Build up RS pressure through MCPA up to 8.0kgs/sq.cms.Re-close DJ.

2. LSGR EXTINGUISHED Bring GR to 'O' manually. Re-close DJ.

3. BA VOLTAGE LESS OR NIL Operate HBA switch few times.Ensure healthiness of additional CCBA/MCB atBA BOXEnsure BA voltage is more than 80 Volts.

4. CCBA, CCPT AND CCDJ a. Renew the fuse. Close DJ.MELTED. b. If unsuccessful — check the fuse and

fuse carrier again.c. In case of CCPT melts, try with other panto.d. If fuse melts again - put HOBA in off position[in all the locos of MU/Consist]. Renew the fuseClean the fuse carrier base - Resume traction.e. If fuse melts again — Request for assistance.

5. IF Q118 NOT ENERGISED a. Close BLDJ & BLVMT. EnsureC118, C105, C106, & C107 are open.Manually close Q118. Close DJ byBLRDJ/BP2DJ.Release Q118 after all theblowers start or after one minute andresume traction.

b. If unsuccessful — Take safetymeasures, Ensure C118 is open, WedgeQ118 and close DJ. Resume traction —clear block section. Observe the workingof all auxiliaries. On arrival at station —Take safety measures. Remove thewedge of Q118. Put HVMT1 & 2, HVSL1& 2, HPH, HVRH, on III and HQCVAR on"0" (If HC 105 is provided put on “0”)afteroperating a few times,

i. If Q118 is energised: Put back all the above switches in position-1 oneby one, close DJ by manual operation of Q118.And observe DJ by releasing Q118.If DJ trips Putthat particular switch on position III ,in case of

Page 22: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

22

HQCVAR & HC105 put on ‘O’.Work the train,while closing DJ manually operate Q118.

(In case of MU manual operation of Q118 in trailing loco is not possible during run .So Put back all the above switches in position-1 one by one, observe Q118 after 5 secs,If Q118 gets de-energised :1) If HVMT-1/HVMT-2/HVRH kept in normal position and Q118 gets de-energised thenput back concerning switch on position III & remaining all other switches on “1”Resumetraction. Observe the working of auxiliary whose switch is kept on position - III. (Relayisolated).2) If on keeping HVSL-1/2,or HPH or HQCVAR on 1.If Q118 gets de-energised thenput HVSL-1&2, HPH on III & HQCVAR on 0. Resume traction. Observe the working ofauxiliary whose switch is kept on position - III. (Relay isolated).

In case HPH is kept on position 3– Continue traction. Observing the followingcurrent rating: — Starting - 920 Amps, for 10minutes, Continuous - 500 Amps.

ii. If Q118 is still de-energised Manually operate C118 & Q46- If Q118 is still de-energised request forassistance

Note: - One 35 Amps Fuse/MCB has been provided in BA-BOX as additional CCBA. Ifany time Driver experienced BA voltage 'Zero' he should positively check thisfuse/MCB.

6. Q118 IS ENERGISED. PRESS BLRDJ/BP2DJOBSERVE Q45 & Q44

A. IFBOTHQ45 & Q44 a. Ensure air control cutout cock isARE ENERGISED open. RDJ drain cock closed.

b. Ensure RS pressure is more than 8 Kgs./sq.cms. Check C118.c. Stand near C118. Ask the Asst. Driver topress BLRDJ. Listen to the closing sound ofC118.

B. IF C118 IS DE-ENERGISED If no closing sound is heard — Take safetymeasure. Operate C118 & QCVAR manually afew times. Close DJ. If unsuccessful — Requestfor assistance.

C. IF C 118 IS ENERGISED Put HQOA on “0”,& HQOP 1&2 in “OFF”. Ifsuccessful try by resetting one by one .CheckVCB pressure 4.8 kg/cm2 If unsuccessful —Request for assistance.

Page 23: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

23

D. IF Q45 ALONE NOT ENERGISED a. Operate BLDJ few times & Change theposition of ZPT. Ensure GR on '0’. Operate GRmanually from 0 to 1 and back to 0 a few times.Close BLDJ, press BLRDJ/BP2DJ — Close DJ.b. If still Q-45 not energised—Operate Q45manually. Release Q45 after LSCHBA goes out.Resume traction.Everey time for closing DJ, Operate Q45manually.c. If DJ does not close—Don't release Q45.Check Q44. If Q44 is energised — try fromother cab.If DJ closes — Resume tractionClear the block section, observing the G&/SR inforce.If unsuccessful — Request for assistance.

E. If Q44 ALONE Operate GR manually from O to 1 and back fewNOT ENERGISED. times. Ensure GR drum indicates 'O'.

Close DJ by BLRDJ/ BP2DJ — Resume traction.If unsuccessful — Close both Q45 & Q44manually.Release Q44 & Q45 after LSCHBA goes out.Resume traction.If unsuccessful — Request for assistance.

F. IF DJ CLOSES ON MANUAL Do not wedge relay Q44.OPERATION OF Q44 AND Ask for assistance/Relief locoDJ OPENS ON RELEASING

Q44

REMARK - II [FOR REAR LOCO IN MU/CONSIST]

In case of ICDJ in leading loco refer Remark -1.On pressing BLRDJ on leading loco, LSDJ remainsglowing but UA deviates and LSGRPT goes out, LSOLremains glowing.

ICDJ on trailing/rear loco in MU/Consist.

i. If the load permits — Clear the block section by leadingloco,

ii.a. On leading loco — Ensure BLSN is in normal/Upposition.Operate BLSN few times. Ensure PT raised ontraining loco. Close DJ. Resume traction.b. If unsuccessful—Tap gently on the BL board near BLSNswitch. Close DJ — Resume traction.

Page 24: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

24

c. If unsuccessful again—while going to trailing loco. (Inwhich LSGRPT remains glowing)Keep leading loco in energised condition, with BLVMTclosed.Ensure proper fitness of the MU jumpers connectedbetween locos.On trailing loco press BP2DJ. Close DJ.

IF DJ CLOSED Come back to leading loco — Resume traction.

IF DJ DOES NOT CLOSE Trouble shoot on trailing loco as per Remark -1.

Use BP2DJ in place of BLRDJ in trailing locos.

IMPORTANT INSTRUCTIONS

a. WEDGING OF Q118 NOT PERMITTED IN TRAILING LOCO.b. WEDGING OF Q118 ON LEADING LOCO IS PERMITTED TO CLEAR BLOCK

SECTION ONLY.c. WEDGING OF Q44 IS STRICTLY PROHIBITED.

LSDJ GOES OUT BUT UA FAILS TO DEVIATE AND LSDJ COMES AGAIN

(NO TENSION ON LINE-CONTINUOUS)

Probable Defect/ Action to be taken by the Driverobservation/checking

1.CLOSE BLDJ, PRESS - put “ON” flasher light & control the speedBLRDJ IF UA DOES NOT upto 60 kmph at nightDEVIATE RELEASE BLRDJ - While on run check OHE, PANTO, TRACKAFTER LSDJ GLOWS AGAIN AND TRAIN,note the Time,KM,& section

-In front and rear.- If any abnormality noticed — lower panto.Stop the train, comply with GR 6.03 — Contact LC/ TPC.If no abnormality is noticed :Ensure Rs pressure is more than 8.0 kgs/sq. cm.Close DJ once in every minute for three times.Don't Release BLRDJ till DJ trips.If tension restores — Continue traction.It still tension not restored :Put other panto into service.If successful — Clear block section.- On arrival at station. Try with original panto. If notripping — Resume traction.If tripping occurs.

Page 25: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

25

Take Power Block and ground the loco. Check loco roof.Observe all safety precautions as given below(REFER IMPORTANT INSTRUCTIONS GIVENBELOW)- If unsuccessful with other panto.Stop the train near an emergency socket.Send ALP to check the train with guardLower the panto. Check loco roof from ground level. Lookfor any abnormality and foreign body.- Contact LC/TPC.

IF UNABLE TO CONTACT - Raise panto once in every three minutes for threeTPC/TLC times.

- If tension not restored — Lower panto. Ask forassistance.- Observe SR 6.04.02 (d)(i).- If tension restored after 05 minutes clear the block sectionat 35/20 kmph as per SR 17.09.01(5)(ii)

LSDJ GOES OUT BUT GLOWS AGAIN BEFORE LSCHBA GOES OUT

OPERATION 'A'

Page 26: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

26

Remark -1 for SURemark - 2 for MU/CONSIST.

Probable Defect/ Action to be taken by Driver.Observation/Checking

REMARK-ICHECK ARNO If found smoke emission, ask for relief loco.

IF QCVAR REMAINS Put HQCVAR on 'O'. Close BLDJ, Press BLRDJDE-ENERGISED and release it after 3 to 5 seconds. (LSCHBA

remains glowing) Resume traction.Observe for any abnormal sound/smoke emissionfrom ARNO.and working of CHBA.

REMARK-II

Trouble shoot as per Remark-I for leading loco.Ensure from leading loco :Panto of trailing loco is touching the contact wire.Proceed to the trailing loco. Do the same operationon trailing loco as given under Remark-I for SU orleading loco in MU/ Consist.Observe for any abnormal sound/smoke emissionfrom ARNO.

NOTE

IF LSDJ FLICKERS — CHECK RELAY TARGETS.IF NO ABNORMALITY NOTICED — ASK FOR RELIEF LOCO

.

Page 27: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

27

LSDJ & LSCHBA GOES OUT BUT LSDJ GLOWS AGAIN WITHIN 15 SECONDSAFTER LSCHBA GOES OUT

OPERATION 'B'

Remark - 1 for SURemark - 2 for MU/CONSIST. Refer page no. 63

Probable Defect/ Action to be taken by Driver.Observation/Checking

REMARK-IRECORD OHE VOLTAGE, SECTION AND TIME.Put HQCVAR on *0* HPH, HVSL-1 and HVSL-2 onposition III.Operate the switches a few times.Close DJ — Wait for 15 seconds.

Page 28: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

28

1. IF DJ HOLDS Observe the working of both MVSL1 & MVSL 2.

A. IF BOTH MVSL-1 & 2ARE WORKING Cear block section.

On arrival at next station - Trip DJ.Put back HQCVAR, HPH, HVSL-1 & HVSL-2 toposition 1 one by one.Each time after closing DJ — Wait for 15 seconds.If DJ trips :Put that switch on III (for HQCVAR put on 'O').If DJ holds: Resume traction.Observing frequently the working of MVSL-1 & 2.On keeping HPH-III.Check for any oil leakage from transformer.Continue traction — Observe following currentratings.Starting - 920 amps -10 minutes.Continuous - 500 amps.

B.IF MVSL 1 OR MVSL2OR BOTH ARE NOT WORKING Isolate the defective blower — Clear block

section. Do not exceed the current ratingscontinous-500 amps.On arrival at next station :If both MVSL1 and 2 are notworking, Request for assistance/Relief locoIf either MVSL1 or 2 are only not working.isloate the corresponding block. Put correspondingHVSL, HVMT & HVSI on '0\ If load permits —Continue traction. If load does not permit — ContactTLC.

2.IF DJ TRIPS. Put back HPH, HQCVAR, HVSL-1 & HVSL-2 onposition 1.Wedge Q118 — Close DJ. Clear block section.Ensure the working of all auxiliaries. Observefor any smoke emission from auxiliaries. Onarrival at the station — contact LC.

ON WEDGING Q118 If unsuccessful

Page 29: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

29

Remove Wedge from Q118. Ask forassistance/Relief loco.

REMARK-II

Trouble shoot as per Remark-I for leading loco

Proceed to the trailing loco.Trouble shoot as given under Remark I for SU andon leading loco in MU/CONSIST.

NOTE

1. WEDGING OF Q118 IS NOT PERMITTED ON TRAILING LOCO.2. On ISOLATING BLOCK-1 — WEDGE C106. (If MVMT2 is not working)

Page 30: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

30

LSDJ GLOWS AGAIN WITHIN 15 SECONDS AFTER CLOSING BLVMT.

OPERATION 'O'

Remark - 1 For SU.Remark - 2 For MU/consist. Refer Page No. 00

Probable defect/ Action to be taken by Driver.Observation/Checking

REMARK-IKeep BLVMT switch in closedposition. Put HVRH, HVMT-1 &2 on position III. Close DJ.Count 15 sees.

1. IF DJ TRIPS - Put the above switches on 1.

Page 31: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

31

- Wedge Q118.Close DJ — Clear block section.Observe the working of blowers of MVRH, M VMT-1 &2.

2.IF DJ HOLDS Check the working of Blowers.

A. IF ALL THE BLOWERSARE WORKING Clear the block section

Observe working of all blowers on run.On arrival at station,Put back the above switches one by oneonposition-l. Close DJ. Close BLVMT.If DJ trips.Maintain that switch on position III.Put all other switches on position-l.Resume tractionObserve the working of the blower,whose relay is isolated.

B.IF ONE OR MORE BLOWERSDO NOT WORK Isolate the defective blower motor.

Follow the instructions given below :

3.A. LOCOS PROVIDED WITHHC105 i)MVRH not working.

Put HVRH on 'O' and HC 105 on 'O'.Clear block section not exceedingcurrent—500 Amps.On arrival at station — Request forassistance.ii)MVMT1 or MVMT2 not working.PutHC105on'O'.Put corresponding HVMT1 or 2, HVSL1or 2 &HVSI1 or 2 on'0'.If load permits — Resume traction.If load does not permit — Contact LC.

3.B. LOCOS NOT PROVIDED i. MVRH not working.HC 105 Clear block section.

Put HVRH on '0' wedge Q118, close DJ.Follow current rating starting 920 Ampsfor10 minutes.Continue 500 Amps.

Page 32: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

32

On arrival at station — Request forassistance.

ii. MVMT1 or MVMT2 not working.Put corresponding HVMT1 or2,HVSL1or2&HVSI1 or 2 on 'O'.If Block 1 is isolated — Take safetymeasures.Wedge C106. Manually operate Q118— Close DJ.If load permits — Resume traction.If load does not permit — Contact LC.

REMARK-IITrouble shoot as the Remark-I forleading loco. Proceed to the trailingloco. Do the same operation as givenunder Remark-I for SU/leading loco.

NOTE1. WEDGING OF Q118 IS NOT PERMITTED ON TRAILING LOCOS.2. IF MVMT1 IS ISOLATED. WEDGE C106.manually operate Q118 to close DJ.

PC-8 Relay PC-8 Relay with wedging

Page 33: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

33

WOAMA Relay with wedging screw COMET Relay with wedging

LSDJ GLOWS AGAIN WITHIN 15 SECONDS AFTER TAKINGONE TRACTION NOTCH

OPERATION -1

Page 34: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

34

Remark -1 for SU.Remark - 2 for MU/consist.

Probable defect/ Action to be taken by Driver.Observation/Checking

REMARK-I- Put HVSI-I & II on position - III.- Close DJ.- Take one traction notch and wait for 15seconds.

1. IF DJ HOLDS Check the working of MVSI-1 & 2.i. If MVSI1 & 2 are working :clear the block sec.a. On arrival at station — Open DJPutt back HVSI-1 & 2 one by one onposition-l. Close DJ. Take one tractionnotch and wait for 15 seconds.If DJ trips.Put that HVSI switch on position III.Put the other HVSI on position I.Resume traction. Observe the working ofblower whose relay is isolated.

2.IF DJ TRIPS AGAIN i. Put the HVSI1 & 2 on position -1. andcheck SMGR pressure between 3 to 3.5kg/cm2 and for any air leakage- Operate GR manually a few times —Resume traction,

ii. If unsuccessful.Isolate the RSI block one by one. If loadpermits — Resume traction, iii.If Unsuccessful — Clear Block Sectionby Manual Control of GR.

3.IF MVSI-1 OR MVSI-2IS NOT WORKING Isolate the corresponding block.

- Put the corresponding HVSI1 or 2,HVSL1 or 2 and HVMT1 or 2 on "O" andHC-105 on «0\ if provided. If load

Page 35: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

35

permits — Resume traction. If the loaddoes not permit — Contact LC.

REMARK IITrouble shoot as per Remark-I for leading loco.Check the proper fitment of theMU jumpers.Proceed to the trailing loco.Do the same operation on trailing loco.InMU/consist — Follow the instructionas given under Remark-I for SU/leadingloco.

LSDJ GLOWS AGAIN WITHIN 15 SECONDS AFTER TAKINGSIX TRACTION NOTCHES.

OPERATION-II

Page 36: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

36

Remark 1 -forSU.Remark 2 - for MU/consist. Refer page No. 68Probable defect/ Action to be taken by the driver.Observation/Checking

REMARK-IEnsure HVRH, HVMT-1 and 2 on position-l.Close DJ.Close BLVMT. Check the working ofblowers.

1.IF ALLTHE BLOWERSARE WORKING a.i. On locos provided with HC 105

Put HC 105 on '0\ — Resume tractionObserving the working of blowers onrun.ii. On locos not provided with HC 105Put HVMT-1 & 2 on position III. Resumetraction. Observing the working of blowers onrun.b. If unsuccessful.Put back all switches in positionI. Wedge Q118. Clear blocksection. Observing the workingof auxiliaries.c. On arrival at station :Take safety measure.-Remove the wedge from Q118.Operate manually - C107, C106 andC105 Resume traction.- If unsuccessful.Take safety measures — Wedge C107,putHVMT1&2 on position IIIOperate Q118 manually. Close DJ—Resumetraction.If again unsuccessful — Request forassistance.

2.IF ONE/MORE BLOWERSARE NOT WORKING. a. Close BLCPD. Check the working of

compressors.i. If the compressors are working :

Take safety measures.Wedge C107, C106 and C105 CloseBLVMT. Manually close Q118 — Close DJ.Resume traction. To close DJ every time —manually operate Q118.

Page 37: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

37

ii. If the compressors are not working—Refer page No. 00 (Miscellaneous failuresfor auxiliaries not working.)

REMARK-IITrouble shoot as per Remark-I for leadingloco. Proceed to the trailing loco. Do thesame operation on trailing loco as givenunder Remark-I for SU/leading loco.During the course of trouble shooting :When one or more blower contactors arewedged.Put HVMT1, HVMT2 and HVRH onposition III. Check Q118.

i. If Q118 is not energised.Come back to leading loco — Resumetraction.

ii. If Q118 is not energised.Put back HVMT1, HVMT2 and HVRH onposition I.Manually operate Q118 on trailing loco.Close DJ with BP2DJ.Resume traction. Clear block section.On arrival at next station.If the load does not permit—Request forassistance.

NOTE1. BEFORE PUTTING HC105 ON POSITION 'O', ENSURE ALL THE

BLOWERS ARE WORKING.2. AFTER PUTTING HC 105 ON '0\ CHECK WORKING OF BLOWERS

EVERY 15 MTS. ON RUN.3. ON WEDGING CONTACTORS C105, C106 OR C107 CLOSE BLVMT,

MANUALLY OPERATE Q118. PRESS BP2DJ TO CLOSE DJ.a. Release BP2DJ after LSCHBA goes out.b. Release Q118 after all blowers start or after 1 min.

Page 38: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

38

TWAC(TRIPPING WITHOUT ANY APPARENT CAUSE)

IF THE TRIPPING OCCURS SPECIALLY ON HIGHER NOTCHES, CHECK THEUA. IF UA SHOWING — BELOW 19KV, CLEAR BLOCK SECTION ON LOWERNOTCHES AND INFORM LC/TPC AT THE NEXT STATION.

observation/checking Action to be taken by the DriverProbable Defect/

1. IF NO TRIPPING ** Continue hauling the train.Enter in the loco Log Book and informLC.

2. IF TRIPPING OCCURS i. Ensure RS pressure more than8.0 kgs./cm

2

ii. Change the position of ZPT.Use EEC —Resume traction.

3.IF TRIPPING OCCURS ** Take safety measures.AGAIN (TWAC) Operate the following switches two or

three times. Check SMGR pressurebetween 3 to 3.5 kg/cm2 and for any airleakage, operate GR manually fewtimesPut HQCVAR on '0\ HVRH, HVMTI,HVMT2, HVSL1,HVSL-2, HVSI-1 & HVS1-2 & HPH onposition III.Operate GR manually few times.Keep HC105 on 'O' (if provided)Put back ZPT on 1 and control with MP.Resume traction.Observe the working of all blowers.

4. IF NO TRIPPING OCCURS ** At next stoppage —Put back the above switches in position-1 one by oneObserve tripping.If tripping occurs by putting anyparticular switch onposition 1 — Keep that switch onposition-Ill.Put other switches on position 1.Resume traction.Ensure frequent checking of blowerwhose relay/relays have been isolated.

Page 39: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

39

In case if HPH is kept on III — Continuetraction.Observing the following current ratings.Starting - 920 amps for 10 minutes.Continues - 500 amps.

5.IF TRIPPING OCCURS AGAIN ** Put HQOP-1 & 2 in 'OFF'position and HQOA on 'O'.Resume traction.

6.IF TRIPPING OCCURS AGAIN Put HOBA in off position(On all locos in MU/Consist) —Resume traction.

7.IF UNSUCCESSFULL Change the cab or loco. Clear the blocksection. Observe instructions of SR,4.21.01 (b)(i).

8. IF UNSUCCESSFULL Try to clear block section by manualcontrol of GR

9.IF UNSUCCESSFUL AGAIN If tripping permits — continue haulingthe train.If tripping does not permit — Stop thetrain at thenext station/emergency socket —Inform LC.Enter in the loco log book.

NOTE 1. ENSURE RS PRESSURE MORETHAN 8.0 KG/SQ. CM AFTEREVERYTRIPPING2. OBSERVE IF LOCO TRIPS IN BETWEEN NOTCH 2' TO 5 ORAFTER NOTCH 6.

Page 40: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

40

CHAPTER-III

TRACTION FAILURES

TOTAL LOSS OF TRACTIVE EFFORT (TLTE)

PAGE

1. Total loss of Tractive Effort or impossibility to startduring traction, Ammeters do not deviate. 00

a. GR is not progressing at all. 00

b. GR is progressing. 00

2. Total loss of Tractive Effort after using Rheostatic Braking. 00

REDUCTION/LOSS OF TRACTIVE EFFORT.

1. a. LSP glows on run without Wheel Slipping with both orone ammeter deviating and GR comes to 'O'.(Auto-regression up to loco No. 23384) 00

b. Autoregression beyond loco no. 23385(Inclusive) 00

2. Auto-Regression of GR without glowing of any lamp onlower notches. 00

3. Autoregression of GR without glowing of any lamp onhigher notches. 00

4. Smoke or Spark or abnormal noise from the TractionMotors. 00

5. GR does not progress beyond one/certain notch in MU. 00

Page 41: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

41

TRACTION FAILURES

A. TOTAL LOSS OF TRACTIVE EFFORTOR

IMPOSSIBILITY TO START DURING TRACTION, AMMETERS DO NOT DEVIATE1a) GR IS NOT PROGRESSING AT ALL

Probable defect/ Action to be taken by the driver.Observation/Checking

TOTAL LOSS OF TRACTIVE EFFORT WITH LSB GLOWING:

I.IF LSB GLOWS[MPJ "F" or "R"] - Take safety measures. Ensure the following

i. J1/J2 are in desired direction.[Cabl-J1, J2 UP/Cab II-J1, J2 DN]

ii. CTF-1, 2 & 3 are in TR' position,iii. C-145 is in open condition.

If no abnormality is noticed - Close DJ.

Page 42: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

42

Put MPJ in forward position, if LSB extinguished,Resume traction,

iv. If LSB still remain glowing :Trip DJ. Take safety measures Wedge Q50.resume traction.

II. IF LSB IS EXTINGUISHEDa. Check and ensure the following.

i. BP pressure to be 5kg/sq.cm.ii. PR-2 is in de-energised conditionIv If QRS is in de-energised condition,

- wedge QRS in eneregised conditionProper fitting of MP couplers (2 nos).Operate EEC — Resume traction.If unsuccessful :Operate MP or EEC from rear cab.Clear block section only.

Observe GR & SR rules in force.b.On arrival at station or if unsuccessful afterchanging cab.

v. ENSURE Q51 IS IN DE-ENERGISEDCONDITION.,

If Q51 is in energised condition,Wedge Q51 de-energised condition — Resumetraction.

vi. ENSURE Q-52 IS IN DE-ENERGISEDCONDITION.If Q52 is in energised condition,Wedge Q52 in de-energised condition —Resume traction.

vii. Ensure ZSMGR knob and ZSMS are in correctposition.

vii. Operate BL few times(both cabs).ix. Check SMGR pressure is 3 to 3.5 kg/cm2

III. IF Q51 & Q52 ARE GOOD(ie. DE-ENERGISED) c.i. Operate GR manually few times from 'O' to 10

Put and back to '0'. Resume traction.ii. If unsuccessful — Clear block section.

Operate manual control of GR inSU/LeadingLoco.

InMU —If load permits — Clear block section with goodloco.If load does not permit — Contact LC.

NOTE : 1. In MU Manual Control of GR on Trailing Loco is not permitted.

Page 43: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

43

2. In MU/Consist operation while working with EEC, Whenever the GR isbrought to 'O' by BPR — bring MP to 'O'. Before progressing — put MPagain On 'N'3. After wedging a relay observe safety precautions as mentioned in pageno.

Precautions on RELAY wedging

When relay Q-50 is wedged:

1. Ensure the correct setting of J-1 and J-2as per the direction and CTF 1-2-3 ontraction side (↑), C-145 fully opened position before wedging Q-50.

2. Do not operate MPJ till the train reaches the relief point.

3. When DJ is tripped on notches keep MP on '0' for GR to regress to '0'.

When relay Q-51 is wedged (or HPAR on ‘0’):1. Relay Q-51 should be wedged in de-energised position.

2. Wedge should be inserted between pallet and core.

3. Auto regression will not take place during wheel slip or QD or Q20 action

takes place or when relay QRS de-energised.

4. Operate sanders o avoid wheel slip. Observe LSP and ammeters for wheel slipindication.

5. Observe BP pressure and vacuum level, to avoid QRS de-energised

6. Check the relay for any over heating. If the relay is over heated, trip DJ, remove thewedge and contact TLC for advice.

When QRS Relay is wedged:

1. Watch and ensure BP pressure and vacuum is adequate and the train is runningsafely.

2. Whenever the train is parted, immediately keep MP on '0' and bring GR to 0 '0'.

3. When RS is opened and A-9 is brought to emergency, keep MP on '0'.

When Q 100 Relay is wedged:

1. Before opening DJ, open all auxiliary switches,

2. After closing DJ, close one by one auxiliary switches with a time gap of 5 seconds

Page 44: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

44

to avoid overload on ARNO.

3. If DJ trips then before closing DJ, bring MP to ‘0’,MPJ to ‘0’ and put HBA ‘OFF’then energise the LOCO as per procedure, otherwise ICDJ will experienced.

When Q 118 Relay is wedged or HOBA is kept in OFF position:

1. Check the working of all auxiliaries frequently whose interlocks are provided in Q118branches. i.e., MVRH, MVMT1, MVMT2, MPH, MVSL1, MVSL2.

2. If any auxiliary does not work (or smoke emission found), then open DJ and lower pantoimmediately and take precautionary measures.

When Q 45 Relay is wedged:

1. Against regular practice on Neutral Section before arriving “close DJ” board do not close

BLDJ.

2. Frequently check the working of MVSI1, MVSI2.

3. Bring MP to ‘O’ and open DJ if found LOW/NO tension on line, so frequently watch ‘UA’

in driving desk.

4. Observe smoke emission from Q30 and RQ30

5. Observe OHE voltage on UA.

When No-tension on line remains for a long time, then remove the wedge of Q45 to avoidchattering sound of Q44, Q118.Precautions after wedging QSVM.

1. BLVMT should be switched on before closing DJ.

2. BLCP should be switched on after 5 seconds of SIV rams up full voltage. (SIV ON LED

glows or LSCHBA extinguishes)

Precautions after wedging QTD101.BLCP/BLCPD should be switched on after 5 seconds of SIV rams up full voltage. (SIV ON LEDglows or LSCHBA extinguishes)

Page 45: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

45

TOTAL LOSS OF TRACTIVE EFFORTOR

IMPOSSIBILITY TO START DURING TRACTION, AMETERS DO NOT DEVIATE1. B.GR IS PROGRESSING

HMCS2

L1 L2

HMCS1 HMCS1

L3 L4

HMCS1 HMCS2

L5 L6

HMCS2

0

HVMT1

21

HVSI1

3

CTF1(TR)CTF2(TR)

CTF3(TR)

Q50

CCPT(10A)+110V

BL1

-,+,N(TR)MP1

BL2

-,+,N(TR)MP2

DJ

2

HVMT2

HVSI2

20 1

0 1

3

3

L3 L4L1 L6

VS3

GR CL 1-32

Probable Defect/ Action to be taken by the driver.Observation/Checking

i. Ensure MR/RS pressure is 8 kg/sq. cm.in the centre locker gauge,

ii. Try from rear cab — Clear block section.Observe GR & SR rules in force.iii. If unsuccessful from rear cabor on arrival at the station.a. Operate HVSI-1, HVSI-2, HVMT-1 and HVMT-2 fewtimes from 1 to 0 and back to 1.b. Operate HMCS1 & HMCS2 few times from 1 to 4and back to 1.c. Check 3 couplers below rotating switch board forproper fitment.d. Manually operate all CTFs few times.Ensure they are in 'TR' Position.e. Check for any air leakage from line contactorsor its pipe line — try to arrest the leakage.f. Check EP 2 cut out cock. If close open EP cock.g. Manually operate line contactors few times.Resume traction.

Page 46: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

46

IF UNSUCCESSFUL TORESUME TRACTION In case of SU Loco — Request for assistance.

In case of MU/Consist —If load permits — Clear block section with good loco. Ifload does not permit — Contact LC.

NOTEIn MU/Consist — During starting or on runIF Ammeters on leading loco deviates abnormally high, check the trailing loco. If GR

progress but both ammeters does not deviate refer 1.b. above.

If both ammeters are deviating on all loco check the train for brake binding.

2. TOTAL LOSS OF TRACTIVE EFFORT AFTER USING RHEOSTATIC BRAKING.

Probable Defect/ Action to be taken by the driver.Observation/Checking

I. IF LSB DOES NOT GLOW. Ensure MP on O and observe LSB with MPJ 'F' or 'R’. IfLSB does not glow, refer page number 00 (TroubleShoot for TLTE during traction).

II. IF LSB GLOWS. i. Take safety measures.Check CTF1, CTF2 & CTF3 are in TR' position.If CTFs are on 'BR' position — bring them to TR'position.(Manually operate the CTF electro valve).Ensure C145 is in open position.If C-145 is closed — Open C145.(Manually operate the electro valve.) Resume traction.

ii. If unsuccessful — try from rear cab.Resume traction — Clear block section.Observe GR & SR in force.

iii. If unsuccessful — clear the block section bymanual control of GR in case of SU.In MU/consist:If load permits — Clear block section by good loco. Ifload does not permit — Contact LC.

Page 47: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

47

NOTE

• In MU manual control of GR is not permitted on trailing loco.• In case of CTFs/Reversers are to be operated manually due to failure of

electrovalves or air pressure, close EP cut out cock first and then setCTFs/Reverser in the required position.After manual operation — open EP cut out cock.

• On opening EP cut out cock if any CTF again back to BR position, secure that CTF withrope in the TR position.

B. REDUCTION/LOSS OF TRACTIVE EFFORT

a. LSP GLOWS ON RUN WITHOUT SLIPPING AND GR RETURNS TO 'O' IN SU ORMU/CONSIST LOCOS UPTO 23384.

Remark -1 ForSU.Remark - 2 For MU/Consist.

Probable defect/ Action to the taken Driverobservation/checking

REMARKS -1Ensure ZQWC is 'OFF' in all cabs.Put HMCs-1 and HMCS-2 on position-ll.Take two traction notches and observe bothammeters.

IF BOTH AMMETERS DEVIATE Put back HMCS-I on position ‘I’.Take two traction notches and observe LSP.

a) If LSP glows —Auto regression of GR takes place.Put HMCS-I on position-ll, HMCS-2 on ‘I’Resume traction.(TM 1 is isolated and UMT 1 will not deviate)

b) If LSP does not glow —Auto regression of GR does not take place.Maintain HMCS-2 on position-ll. Resumetraction. (TM. 4 is isolated and UMT-2 will notdeviate)

IF LEFT HAND SIDEAMMETER (A1) DOESNOT DEVIATE Put HMCS. I on IV (TM. 3 is isolated) Resume

traction.

Page 48: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

48

IF RIGHT HAND SIDEAMMETER (A2) DOES

NOT DEVIATE. Put HMCS-2 on IV (TM 6 is isolated). Resumetraction.

REMARK-II.Trouble shoot as per Remark-I for leading loco.

Put BLSN down on leading loco.Check the TMs (Ammeter) as per trouble shootingmentioned in Remark. 1.If no trouble is experienced on leading loco.Proceed to trailing loco.Do trouble shooting by keeping BLSN downon the trailing loco as per Remark-I.

connection of ammeter--voltmeterALL WAG-5A & WAG-5B up to 23384

1. Left hand ammeter Al indicates current for TM3 in both cab.

2. Right hand ammeter A2 indicates current for TM6 in both cab.

3. UMTI in cab 1 indicates voltage for TM1.

4. UMT2 in cab 2 indicates voltage for TM4.

5. QD1 connected between TM1 & TM3.

6. QD2 connected between TM4 & TM6.

Position of HMCS HMCS-1 HMCS-2

I TM-1, 2 & 3 are TM-4 5 & 6 are

in service. in service.

II TM-1 isolated. TM-4 isolated.

III TM-2 isolated. TM-5 isolated.

IV TM-3 isolated. TM-6 isolated.

Page 49: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

49

1.b. LSP GLOWS ON RUN WITHOUT SLIPPING AND GR COMES TO 'O' ONSingle/MU/consist for locos 23385 WAG-5A and onwards

Remark-1 For SU.Remark- 2 For MU/Consist.REMARK-IEnsure ZQWC is 'OFF' in all cabs.Put HMCS-1 & 2 on position III and take two traction notches. Observe both ammeters.

Probable Defect/ Action to be taken by the driver.Observation/Checking

I.IF BOTH AMMETERSDEVIATE. Put HMCS-1 on position-l and take two traction notches

Observe for auto regression of GR with LSP glow.a. If LSP glows - with auto regression Put back HMCS-1 on

position-Ill and HMCS-2 on position-l. Resume traction. (TM-2isolated).

b. If LSP does not glow -Auto regression does not takes place. MaintainHMCS-2 on position-Ill. Resume traction. (TM-5isolated).

II. IF LEFT HAND SIDEAMMETER (A1) DOESNOT DEVIATE. Put HMCS - 1 on position-IV and HMCS-2 on position-1.

Resume traction (TM-3 isolated).

III.IF RIGHT HANDSIDE AMMETER (A2)DOES NOT DEVIATE. - Put HMCS-2 on position-ll and HMCS-1 on position-l.

Resume traction (TM-4 isolated).REMARK II

Trouble shoot as per Remark-I for leading loco. Put BLSN down on leading loco.Check the TMs as per instructions given in Remark-I.If no trouble is experienced on leading loco. Proceed to trailing loco.Do trouble shooting by keeping BLSN down on the trailing loco as per instructionsgiven in Remark-1.

NOTEOn locos 23385 (WAAG-5A) and onwards. In case of reduction of tractive effortwithout auto regression of GR.Observe UMT-1/U1 in cab-1 and UMT-2(U2) in cab-2.If UMT-1(U1) is not deviating put HMCS-1 on position-ll (TM-1 isolated).Resume traction.If UMT-2(U2) is not deviating put HMCS-2 on position-IV (TM-6 isolated).Resume traction.

Page 50: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

50

CONNECTION OF AMMETERS-VOLTMETERS-QD FOR LOCOS 23385 ONWARDS

1. Left hand side ammeter (A1) in both cabs indicate current for TM3.2. Right hand side ammeter (A2) in both cabs indicate current for TM4.3. UMT-1 incab-1 (U1) indicate voltage for TM1.4. UMT-2 in cab-2 (U2) indicate voltage for TM-6.5. QD-1 is connected between TM-2 and TM-3.6. QD-2 is connected between TM4 and TM-5.

POSITION OF HMCS HMCS1 HMCS2

I TM 1 -2-3 are in service. TM 4-5-6 are in serviceII TM 1 is isloated TM 4 isloatedIII TM 2 isolated. TM 5 isolatedIV TM 3 isolated. TM 6 isolated.

2.AUTO REGRESSION OF GR WITHOUT GLOWING OF ANY LAMP ONLOWER NOTCHES.

CCPT(10A)

-VE

+ 110V

BPP1 BPR2

CLCL6 'O'CLOCK6 'O'CLOCK

VE2

6-32GR CL

32-1

POSITIONPOSITION

GR CL

ZSMGRZSMGR

CL

Q52

Q50

Q51

BL1

1 2ON-,0

MPCL

ON 1ZSMS

BPR1

ON'O'ZSMSCL

BPP2

ON'O'CLZSMS

ON'O'ZSMS

CL

MPCL ON N,01 2

ON'O'CLZSMS

Q51

Q50

BL2

Probable Defect/ Action to be taken by driver.Observation/Checking

1. BL DEFECT a. Operate BL in both cabs few times. Try to resumetraction.b. If unsuccessful, resume traction with EEC.

Page 51: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

51

c. If unsuccessful, clear block section from rear cab,Observing GR & SR rules in force.

3.AUTO REGRESSION OF GR WITHOUT GLOWING OF ANY LAMP ONHIGHER NOTCHES.

ACTION OF Q20(ENERGISED) If auto regression is experienced without the use of

MPS.It may be due to the action of Q20.Note the TM voltage at which auto regression takesplace.Resume traction — Work at lower notches.

Note : Do not use MPS,If auto regression takes place with glowing of LSPon using MPS.

4. SMOKE OR ABNORMAL NOISE FROM THE TRACTION MOTORS

Try to locate the position of the damaged traction motor

1. TRACTION MOTOR IS DAMAGED - If the damaged traction motor isdetected. Stop the train. Isolate the damaged TM — Resume traction.

2. SMOKE EMISSION FROM SUSPENSION BEARING GEAR CASE - Detectthe damaged suspension bearing. Isolate the corresponding traction motor.Clear block section cautiously. On arrival at station — Ask for Relief loco.

3. SLIPPED PINION - If the damaged traction motor is not detected. Stop thetrain. Advise the Asstt. driver to stand near the track. Apply IAB, take twotraction notches. Ask the Asst. Driver to observe Armature of all tractionmotors.If any armature rotates —Isolate the corresponding traction motor.Resume traction — Clear block section.On arrival at station — request forassistance/Relief loco.

4. LOCKED AXLE. - By moving loco. Observe the rotation of all the wheels.If any pair of wheels are not rotating—isolate that particular TM. Move theloco forward and backward two to three times. Observe wheel rotation.If all wheels are rotating - Continue traction. If any pair of wheels is notrotating — Request for assistance.

5. GR DOES NOT PROGRESS BEYOND ONE/CERTAIN — NOTCH SU-MU/CONSIST.- Bring MP to '0'. - Try with EEC and resume traction. - If unsuccessful,A. CHECK Q52 IN SU - Wedge Q52 in de-energised condition [for SU].

IF ENERGISEDB. IN CASE OF MU - Wedge Q49 in de-energised condition.

on affected/trailing locos — Resume traction.

Page 52: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

52

CHAPTER-III

MISCELLANEOUS FAILURES

1. PNEUMATIC FAILURES PAGE NO.

a. MR pressure not building up/maintaining 00b. RS pressure not building up. 00c. BP pressure not building up/maintaining 00d. BP not dropping by DAB/A- 00e. Loco brakes not releasing 00f. B.P. pressure fluctuating on run 00g. Vacuum does not build up/maintaining 00h. ACP on WAP 4 locos. 00

2. ELECTRICAL FAILURES -

a. Pantograph failures 00

b. DJ locked in closed position 00

c. All auxiliaries are not working (CCA fuse melted) 00

d. All pilot lamps not glowing during opening of DJ. 00

e. MVRH, MVMT-1 OR MVMT-2 does not start on closing BLVMT 00

f. LSGR alone extinguished during preparation on line 00

g. LSCHBA glows on run without tripping 00

h. CPA does not start when ZCPA is closed 00

i. Cab lights/compartment lights are not glowing 00

j. Marker lights does not low 00

k. Head light does not glow 00

I. LSB remains glowing with MPJ on F or R 00

m. Notch repeater is not working 00

Page 53: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

53

n. Cab fans are not working 00

o. Cab heaters are not working 00

P. All sanders are not working 00

q. LSB does not glow when MP is placed on 'P' 00

r. LSB glows when MP is placed on 'P' but does not extinguish 00

s. LSB glows during RB 00

t. LSB remains glowing when MP brought to 'O' from RB 00

u. LSRSI remains glowing. 00

1. PNEUMATIC FAILURES

Abnormal sign orobservation Action to be taken by driver.

Ensure BLCPA or BLCPD is ONa. MR PRESSURE NOT i. MCP not working

BUILDING UP/ Change the position of ZCP/HCP. CheckMAINTAINING C101/102/103.If C101/102/103 open

— Check CCAIf melted — Refer Page no. 00 (CCA melted).ii. MCP workingCheck the MR gauge in both the CABS. If both CABSpressure shows "O" or less, Change the position ofZCP/HCP. If pressure does not building up.i. Ensure DAB isolating cocks are open in driving cab.ii. Check leakage from safety valve, unloader valve,Auto Drain valve, MR drain cocks, sanders, MU airhoses & Angle cocks C2 relay valve, D1 & D2Assistant Driver Emergency valves. Ensure MR4 cutout cock is open,iii. In case of leakage from one of the unloader valvesor safety valves — isolate the corresponding MCP.iv. In case of leakage from all unloader valves orsafety valve — Isolate VEAD isolating cock. Workwith BLCPD.v. In case of air leakage from sanders.

Page 54: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

54

Abnormal sign Action to be taken by driver.or observation

Isolate the corresponding sander electro valve. Closethe sanding cut out cock,vi. In case of leakage or damage from MU air hose.Isolate angle cock between the locos. Build up MRpressure individually on each loco. Resume traction,vii. In case of air leakage from Auto Drain valve.Close Auto Drain valve isolating cock,viii. In MU/Dead loco — Ensure LT cock/MU-2Bon trailing loco is on closed/trail position.ix. Ensure no leakage from IP. If there is anyleakage from IP. Close I.P. isolating cock.x.Observe continuous air leakage from air dryer iffound so, then isolate air dryer.

b. RS PRESSURENOT BUILDING UP i.Ensure BA voltage is more than 80 Volts,

ii. Ensure CPA is workingiii. Ensure RAL is openiv. Ensure RS drain cock & CPA drain cocks isclosed,v. Change the panto,vi. Check leakage from CPA, safety valve, VEPT,RDJ and its drain cock, DJ oil separator.If there is no leakage — Close RAL cock.Build up pressure for ten minutes.Even if RS gauge does not indicate any pressure.Raise panto — Close DJ.vii. Tap RS non-return valve gently(Z type)

c. BP PRESSURENOT BUILDING UP/MAINTAINING. Close BP angle cock of loco towards train.

Check BP gauge in both CABS,

I. If BP pressure is building up.Check the train for any leakage,II. If BP pressure is no building up.

Check the following :a. Ensure isolating cocks of DAB/A9 are properly open in the driving cab.LT cock open, MU-2B is in lead position.b. In MU :Ensure LT cock is in closed position and MU-2B on Trail position on trailinglocos.

Page 55: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

55

c. Check leakage from :i. DAB/A9 - Operate A9 few times - properly. Drain the moisture in MR.

Abnormal sign Action to be taken by driver.or observation

If unsuccessful — Change the cab. Work the train as per GR & SR rulesin force,ii. C-2 VALVE - If necessary, gently tap. iii. D1/D2 — Emergency valve ifnecessary, operate few times, iv. In MU : Check BP air hose and anglecock for leakage or damage in MU.AIR-STOCK- Close BP angle cock between locos. Energise from trailingloco — Clear block section.VACUUM-STOCK — Do same operation. Wedge QRS on trailing loco.Energise from leading loco. Resume traction. — Clear block section.On arrival at next station -Change the damaged BP hose of loco.

d. BP NOT DROPPINGBY DAB/A9 1. Operate DAB/A9 a few times.

2. If unsuccessful, drain MR.3. Ensure in non driving cab,DAB (A9) isolating cocks are in close position.4. If still unsuccessful drive from rear cab.Observe GR & SR rules in force.5. Gently tap BP charging C2 relay valve

e. LOCO BRAKESNOT RELEASING i. Keep IAB/DAB in released position.

ii. Move the isolating cock of C3W distributor valvetowards CAB-1.

iii. Release C3W distributor valve of loco/locos.Ensure the brake cylinder gauge needle comes to'O'.

iv. In MU Ensure MU2B valve in trail position intrailing loco,v. Drain out full presure.Rebuild pressure — Releaseloco brakes. If still brake do not release. Tap gentlyon C2 relay valve of brake cylinder.vi.Isolate bogie brake C.O.C & ensure all BC pressuregoes to atmosphere through the C.O.C vent ,thenopen the C.O.C

f. BP PRESSURE

Page 56: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

56

FLUCUATINGON RUN. Use BLCPD. Maintain minimum 9 kg sq. cm. MR

pressure.

Abnormal sign Action to be taken by driver.or observation

g. VACCUM DOES NOT If vacuum indicate 'O'.BUILD UP/DOES NOT Check the contactor C111/C121.MAINTAIN If contactor C111/C121 is open.

Check the position of HCP.HCP should be in T, 'II' or 'III' position.Check BP pressure — It should be 5 Kgs/sq.cm.Check QRS - If it is not energised.Wedge QRS in energised condition.If unsuccessful .Take safety measures.Wedge the contactor C111/C121.If vacuum indicates less than minimumCheck the rear cab vacuum gauge.

Change the position of ZPV .If vacuum still does not Indicate Ensure DAB on release.D1 & D2 in normal position and operate 2/3 times. Vacuum hosepipe onboth ends is properly coupled/ secured.VTP cock is open on singleunit/leading loco. VTP cock is close in all trailing locos.HS4 pressure isbetween 1.4 to 1.7 Kgs/sq.cm.

.

NOTE

1.By reducing the Control Reservoir pressure to 1.4 Kgs. by HS4 Valve, vacuummay be increased by 4 to 5 cms. 2.2.In case of Vacuum stock, if leading loco is defective Wedge PV Contactors(C111/C121)

h.ACP ON WAP4 LOCOS i. Check ACP function. Put MPJ in F or R.Put BLVMT 'ON'. Press 'TS' for 5 secs,ii. If ACP buzzer blows continuouslyPress 'BIS' switch to stop buzzer sound.

Page 57: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

57

Abnormal sign Action to be taken by driver.or observation

2. ELECTRICAL FAILURES

A. PANTOGRAPH FAILURESi. Check MR/RS pressure is more than 8 Kgs./sq.cm.ii. Change the position of ZPT.iii. If other panto raises - resume traction.iv. If other panto does not raise - check CCBA &CCPT.v. If CCBA & CCPT are good - check VEPT isolating cocks for proper opening.

Operate VEPT manually few times — Resume traction,IF CCPT MELTS i. Renew the fuse — Resume traction,IF CCPT MELTS AGAIN ii. Put HOBA in 'OFF' position on ail locos.

Renew CCPT — Resume traction,IF CCPT AGAIN MELTS iii. Change the panto.

If unsuccessful — Request for assistance.IF PANTO IS DAMAGED iv.Stop the train. Take emergency power block.

Secure the panto & broken parts properly.Open the concerning HPT.Close the concerning VEPT cut out cock.Resume traction with other panto.

B.DJ LOCKED IN CLOSED POSITIONI. LSDJ extinguished on unlocking BL i.If the panto is raised —LSDJ NOT GLOWING BUT LSCHBA, Lower the panto immediately.LSGR & LSGRPT GLOW.IF MPJ kept Ensure glowing of LSDJ in other cab.“F”or “R” LSB lamp will glow ii.If LSDJ glows — Resume normal

OR traction,iii. If LSDJ does not glow — increaseMR/RSPressure to more than 8 kgs./cq. cm.— open BLDJ.

iv. If LSD J glows — Resume traction.v. If LSDJ does not glow — CloseBLDJ press BLRDJ raise panto andobserve UA.

Page 58: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

58

Abnormal sign Action to be taken by driver.or observation

II. On opening BLDJ, vi. If UA deviates —LSDJ does not glow, Release BLRDJ when LSCHBA goes out.UA does not drop to zero, Resume traction. Clear Block Section.auxiliary noise does not Observe UA & LSCHBA on run. Inform LC.reduce.

OR

In case of NO-Tension vii. Frequently check for any smoke emission fromon line LSDJ does not glow. power/auxiliary circuit.UA drops to zero LSCHBA Ensure proper functioning of the auxiliaries on run.glows and auxiliary sound Check safety relay targets.

reduces. viii. If UA does not deviate — lower panto.Observe instructions on page number 8 for'No tension' on line.

NOTE

To trip DJ at neutral section or whenever necessary — Lower Panto,To close DJ observe, instruction as, given above.

C. ALL AUXLIRIES Check CCA FUSENOT WORKING

1. IF CCA GOOD I) Check Q-100 with DJ closed.I. If Q 100 de-energised.Trip DJ, wedge Q100 and resume traction. Ifunsuccessful - wedge all contactors. Close DJ bymanually operating Q118. Resume traction.

IF Q100 IS ENERGISED,Take safety measures — wedge all contactors. CloseDJ by manually operating Q118. Resume traction.

2. IF CCA IS MELTED. Open all aux. switches.Renew the fuse CCA and close DJ.I. If CCA melts again.i. Put 'OFF' HOBA on all locos in MU/consist.Renew CCA and close DJ.ii. If CCA again melts — Observe instructions initem-5, Page 84.

Page 59: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

59

iii. In MU/consist:if load permits—clear block section with good loco. Ifload does not permit — contact LC.[Press BLSN for checking defective loco] II. IfCCA holds —Close BLCP(A), BLPV & BLVMTone after another and observe CCA.

3.IF CCA MELTS AFTERCLOSING BLCPA i. Change the position of HCP/ZCP on

SU/Leading loco. Renew the fuse CCA andresume traction.

In MU : if load permits, clear block section withgood loco, ii. If CCA melts again —put HOBAOFF, renew CCA and clear block section, Ifunsuccessful or on arrival at station—PutHOBA normal, put off BLCPA.Put HCP onposition '0' on defective loco. Take safetymeasures.Wedge contactors C101/C102/C103.Create leakage by opening MR drain cock.Renew CCA — Resume Traction.

4. IF CCA MELTS AFTERCLOSING BLPV. i. Change the position of ZPV to position III &

IV one by one.ii. If CCA holds is position III or IVResume traction by maintaining ZPV, in thatposition,iii. If CCA melts in all positions of ZPV. put HOBAOFF, renew CCA and clear block section, Ifunsuccessful or on arrival at station—Put HOBAnormal,Replace CCA. Take safety measures.Wedge PV contactor C111/C121 onSU/Leading loco in MU.Do not close BLPV — Resume traction.

5.IF CCA MELTS AFTERCLOSING BLVMT SU or leading loco of MU

put HOBA OFF, renew CCA and clear blocksection, If unsuccessful or on arrival at station—Put HOBA normal,Replace CCA.Wedge all contactors. (C-105, C-106, C-107, C-101,C-102, C-103, C-111, C-121 as per requirement)

Page 60: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

60

and also wedge Q-100 in de-energise condition.Resume Traction by operating Q118 manually. Workthe train upto destination after taking otherprecautions.In MU on trailing Loco.i. If load permits — Continue traction with leading

loco,ii. In MU if leading loco is defective : Follow as

above.

D.ALL PILOT LAMPS ARE i. Check CCLS — If melted renew fuseNOT GLOWING DURING. Resume traction,OPENING OF DJ. ii. If CCLS melts again—put HOBA in 'OFF position in

all locos. Renew the fuse CCLS. Resume traction, iii.If CCLS again melts — wedge QRS. clear blocksection.

E.THE BLOWER MVRH, Ensure HVRH, HVMT1 & 2 are on Position I.MVMT1 OR MVMT2 DOES i. Check the contactor C107, C105 & C106 ii. IfNOT START WHEN BLVMT any contactor is found open. Take safetyIS ON measures. Wedge the contactor. Resume traction.

Close DJ operating Q118 manually.

F.LSGR ALONE, Check LSGR bulb in other cab.EXTINGUISHED Check the GR drum.DURING PREPARATION If GR drum is not on 'O',OR LINE. Bring GR drum to 'O' by manual operation.

G.LSCHBA GLOWS ON RUNWITHOUT TRIPPING. Continue traction and on arrival at station –

I. Put HBA on 'O' — wait for 15 seconds.II. If DJ does not trip-put back HBA to 'ON'

position ignore LSCHBA. Resume traction.III. If DJ trips- Check the cartridge fuse provided

on Battery Charger (CHBA).IV. If the fuse is melted-replace with 16 amps

fuse. Resume traction,

V. If the fuse is good-check the BA voltage. if it ismore than 80 volts, put HCHBA on 'O'. PutHBA to normal. Ensure BA voltage is morethan 80 volts. Inform LC. Enter in the Loco logbook. Work the Locomotive for 4 hrs.

Page 61: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

61

H.CPA DOES NOT a. Check fuse CCBA.START WHEN ZCPA b. If fuse is melted - replace fuse CCBA.IS CLOSED. c. If it melts again - put HOBA in 'OFF' on all

locos. Replace fuse CCBA - Resume traction.d. If the fuse is good - check the terminal of ZCPA. Ifdisconnected, connect the same. Resume traction.

I.CAB LIGHTS/ Ensure bulb is good. Check CCLC. IfCOMPARTMENT LIGHTS fuse CCLC is melted — Renew fuse.ARE NOT GLOWING.

J.MARKER LIGHTS ARE NOT Ensure bulb is good. CheckGLOWING. CCLF1/CCLF2. If fuse CCLF1/CCLF2 is melted -

Renew fuse.

K.HEAD LIGHT DOES Put on BLPRRNOT GLOW a. If the rear head light glows check the front

head light holder, if it is 'OK' - Change thebulb.b. If the rear headlight does not glow.i. Check ZRT. Ensure it is in 'ON' position,ii. Check 6A cartridge fuse on RTPR.If melted renew fuse.Check glowing of the head light.iii. Change switch position of DC-DC converter

L.LSB REMAINS GLOWING a. Check the reversers.MPJ ON ‘F’ OR 'R’ POSITION Ensure reversers are thrown in correct direction and

correct position by manual operation. CTF1, 2 & 3 areon TR position. C145 is open. Resume traction.b. If unsuccessful - Check Q50.i. If energised - Resume traction,ii. If Q50 is not energised.Wedge 50 in energised condition,Ensuring J1, J2 & CTF are in proper position.Resume traction.c. If unsuccessful-clear block section. Carry outmanual control of GR.

M.NOTCH REPEATER Continue traction. Enter in the locoIS NOT WORKING logbook Inform TLC.

.

Page 62: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

62

N.CAB FANS ARE NOTWORKING. Check CCVT - If melted renew CCVT.

O.CABHEATERS ARE NOTWORKING Check CCRA-1/CCRA-2, If metled renew fuse.

P.ALL THE SANDEERS Check CCLS/CCSA - if melted renew fuse.ARE NOT WORKING. Ensure all VESA isolating Cocks and all sanding Cut

out cocks are open. Ensure sand in sand boxes.

Q.LSB DOES NOT GLOW Bring back MP to 'O'.WHEN MP IS PLACED ON 'P' Ensure LSB bulbs are good — Do not use RB..

R.LSB GLOWS WHEN MP IS Bring back MP to 'O'. Do not use RB.PLACED ON 'P' BUT DOESNOT EXTINGUISH.

S. LSB GLOWING DURING RB. i.Bring MP to '0' - Wait till LSB extinguishes.ii.Check QF1, QF2 and QE.iii.If any of them is showing RED, reset & useRB.iv. If LSB glow again and the above targetdrops -Do not use RB.v. If all targets are normal Use RB notexceeding - 650A/325V.

T. LSB REMAINS GLOWING i. Ensure CTF1, CTF2 and CTF3 are on TRWHEN MP BROUGHT TO and C145open. Use RB.'O' FROM RB. ii. If the trouble again occurs - do not use RB.

U. LSRSI GLOWS ON RUN/REMAINS GLOWING Ignore LSRSI - Clear Block section. On arrival

at next station - Stop the train. Open DJ.Lower the panto and open HBA. ObserveLSGRPT/LSOL in MU/CONSIST. Check theTell - tale fuses.

1.IF1 OR 2 OR 3 FUSES ARE Remove the melted tell-tale fuses. AfterMELTED IN THE SAME ARM LRRSI is extinguished. Resume traction -

Inform LC.

2.IF 4 FUSES ARE MELTED Remove the melted Tell-tale fuses.

Page 63: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

63

IN THE SAME ARM Isolate the corresponding block. If load permits- Resume traction. If load does not permit -Contract LC.

3. IF NO FUSE IS MELTED Ignore the glowing of LSRSI.Enter in the loco logbook - Inform LC.Resume

traction.

Page 64: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

64

REVERSER J – 1 & J - 2

TO PUT REVERSER IN NEURAL POSITION (In Dead Loco)

CTF-1, CTF-2 & CTF-3

Page 65: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

65

TROUBLE SHOOTING FOR STATIC CONVERTER LOCO

Page 66: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

66

ICDJ

1.Ensure QSIT in de energise & LSSIT extinguished, check SIV panel also in addition tonormal checks.2.Trouble shoot as per TSD.& follow the following trouble shooting

i)If Q45 & Q44 both energized, then ensure RDJ drain cock closed, air controlcutout cock is open, check VCB pressure 4.8 kg/cm2,MR/RS pressure more than 8kg/cm2 & then close DJ.If unsuccessful

ii) Put HQOP-1&2 in ‘off’ position & close DJ.If unsuccessful

iii) Put HOBA in ‘off’ position.If unsuccessful

iv) Put HBA in ‘off’ for 3 minutes &close DJ.If unsuccessful

v) Contact with TLCNO TENSION ON LINE (If provided, H-3 will also glow)

Trouble shoot as per TSDNote: In case of OHE voltage above 31 KV & SIV does not start but DJ in closedcondition ,Contact TLC/TPC or wait for normal tension in OHE.LSRSI REMAINS GLOWING

Trouble shoot as per TSDTWAC

Trouble shoot as per TSD.If unsuccessful

Put HBA in ‘off’ for 3 minutes &try.DJ trips through all safety relays except QSIT

Trouble shoot as per TSDDJ trips through QSIT & LSSIT glows

i)Check all auxiliary circuit for smoke emission from all auxiliary motors,contactor panel, switch panel,SIV panel, cab fan,cab heater etc.In addition seedisplay of VFD panel for fault message & also check any fault LED glowing.If smoke emission found:- Trouble shoot as per TSDIf smoke emission found from SIV panel: - contact with TLC after taking safetyprecautions as per GR&SRii)If no abnormality found:-

Reset QSIT, close DJ & resume tractioniii)If unsuccessful :-

Remove CCSPM & change the position of HRAVT one by one, changethe position of HCP/ZPV,Reset QSIT,close DJ

iv) If unsuccessful:-Put all the auxiliary switches on ‘0’& BLCP,BLPV&BLVMT in open

position ,Reset QSIT & close DJ.If successful, Put all switch to normal position one by one & isolate the

faulty motor/auxiliary and work accordingly.v) If unsuccessful:-

Put HOBA/HBA in ‘off’ for 3 minutes &try.

Page 67: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

67

vi) In case of earth fault indicationPut HSIV in ‘0’ position, Press earth fault bypass push button(ELD).Reset QSIT ,Close DJ& clear block section within 45 minutes.Then contact TLC.

vii) If unsuccessful:-Contact with TLC with SIV MAKE & fault message in VFD panel.

OPERATION- A (While closing DJ releases BLRDJ as soon as LSDJ extinguished)Checking sign: Same as conventional locoProbable cause :- i) Q30 or its NOI on Q44 branch

ii)GR on ‘0’ I/L on Q44 branchiii) NCI of QCON on Q118 branch

Trouble shooting:-Close DJ & try to release BLRDJ after LSCHBA extinguishes.a) If DJ trips before releasing BLRDJ:-Close DJ by manually operatingQ118 every time (NCI of QCON on Q118 branch defective)b) If DJ trips after releasing BLRDJ:-Wedge Q45 in energise condition& clear block section with safety precautions

OPERATION- B (BLVMT should remain in open position)Checking sign: Same as conventional locoProbable cause :- i) NCI of C105, C106, C107 on Q118 branch

ii) MPH/QPH, MVSL/QVSL-1&2Trouble shooting:-

Close BLVMT first, and then check operation B.i) If DJ holds: - Resume traction, always close BLVMT before closing DJii) If DJ trips: - Trouble shoot as per TSD (QCVAR is removed in this

loco)OPERATION-O

Checking sign:-Same as conventional loco (Wait15seconds after LSCHBA goes out)Probable cause: - Same as conventional locoTrouble shooting: - Same as conventional loco

Note:- On isolating Block -1, wedging of C-106 & manual operation of Q118 is notrequired

OPERATION-IChecking sign:- Same as conventional locoProbable cause: - Same as conventional locoTrouble shooting: - Same as conventional loco

OPERATION-IIChecking sign:- Same as conventional locoProbable cause: - Same as conventional locoTrouble shooting: - Same as conventional loco

Note:-After wedging any blower contactor manual operation of Q118 is not required.

MISCELLANEOUS FAILUREA) DJ closes but SIV does not start:-

Page 68: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

68

a) Check OHE voltage, if more than 31 KV, wait till OHE tension becomesnormal or contact with TLC/TPCb) Check CCINV,If melts, renew the sameIf again melts, put HOBA position & try.c) If CCINV is good:-Close BLVMT, SIV will start after 2 seconds & resume normal traction.If unsuccessful or on closing BLVMT, SIV does not restart:-a) Check QSVM,If de-energised, check CCAIf CCA melts, renew the same,If CCA again melted, Put HOBA in ‘OFF’ position.If CCA found good, trip DJ & wedge QSVM, Resume traction

(BLVMT to be switched ON before closing DJ)b) If QSVM in good conditionPut HBA in ‘off’ for 3 minutes &close DJ.If unsuccessful isolate all the auxiliaries.If successful put normal one by one.If unsuccessful Contact TLC.

NOTE:-Do not operate any programme switch when SIV is in ‘ON ‘condition.B) QCON defective:-

Indication:-i)LSCHBA does not extinguish, DJ remains in closed condition& SIVremains in ‘ON’ position

ii)CP will not work on closing BLCPAor BLCPDiii)H-1 lamp will not glow.Trouble shooting:-Wedge QCON in energized condition with following precautionsi)While closing DJ manually operate Q118ii)BLCPA to be put ON after 5 seconds of SIV picks up.iii)If experienced ICDJ after wedging QCON,first close DJ ,then wedge QCON

C) CCA melts:-Indication:-i) All auxiliaries running with contactors will not startii) On closing BLVMT, SIV will not restart.iii) On run Auxiliaries stop working, if GR is above 5th notch, DJ will trip.Trouble shooting:-i) Open HBA,Renew CCA,then close HBA,if again melts-Put HOBA in ‘OFF’ position & try.if again melts- Put back HOBA in ‘ON’ position, remove CCA,wedge requirednumbers of contactor , QSVM &follow precautions:-

a) Create leakage from MR drain cockb) Before closing DJ,close BLVMTc) While closing DJ, manual operation of Q118 is not

required

ii) If CCA holds- a) close BLCPA, check CCAif melts- Close BLCPD,resume traction

Page 69: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

69

if melts again on closing BLCPD-1) Change the position of HCP &renew CCA

If melts again-1) Put HCP on ‘0’2) Wedge contactor of CPs (as per requirement)3) Open BLCP, renew CCA4) Create slight leakages from drain cock of MR

b) Close BLVMT, check CCAif melts-

2) Open BLVMT & renew CCAWedge C105, C106, C107, and QSVM & followprecautions:-

a) Before closing DJ,close BLVMTb) While closing DJ, manual operation of Q118 is not

required

D) All CP’s are not working:-Close BLVMT, check working of blowers,-If blowers are not working-follow trouble shooting of CCA melting as above-If blowers are working, try with BLCPD-if unsuccessful, check QTD-101-if found in de-energise condition, wedge it in de-energise position(pre-caution-Close BLCP after 5 seconds of extinguishing LSCHBA)-if unsuccessful,wedgecontactor of CPs(as per requirement)

E) All Blowers are not working:--If CP’s are not working-follow trouble shooting of CCA melting as above-If CPs are working- wedge C105, C106, C107 &QSVM-Before closing DJ, put ‘ON’ BLVMT- Manual operation of Q118 is not required to close DJ

Page 70: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

70

TROUBLE SHOOTING FOR STATIC CONVERTER LOCO DESIGNED BYSIEMENS

Duties of Loco Pilot when DJ/VCB trips.

Sr.No Display panel Loco Pilot Duties

1 Input voltage out of range 1. Again close VCB,& check OHE voltage in UA

it should be between 16.5 to 31 KV. If it is out of

range then contact TPC/TLC. Put HBA on 0 &

close VCB after putting HBA on 1 .

2. If unsuccessful, ask for Relief loco.

2 Static Converter internal fault 1. Put HBA on 0 for 5 minutes then put on HBA

on 1 and energise the loco.

2. If unsuccessful, ask for relief loco.

3 Out side fault / External fault withfault message on scroll display asfollows:

*RECT OVERLOAD LOCK

* RECT OVERCURR LOCK

* INV FAULT MASTER

1. Put HBA on 0, isolate defective auxiliary

motor if any, again put HBA on 1 and energise

the loco.

2. If unsuccessful, put HBA on 0.

Isolate all auxiliaries by operating corresponding

switch. Put HRAVT on 0 if provided.

If HRAVT is not provided remove CCRA-1,

CCRA-2, CCVT fuses, trip manually MCB of

TFVT and open all BL switches.

3. Put HBA on 1 and close VCB.

a. If DJ trips again, ask for relief loco.

b. If DJ holds, put one by one auxiliary switch on

normal position and close DJ. On putting a

particular switch on 1 if DJ trips, put that

particular switch on 0 and work the train

Page 71: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

71

following relevant precautions.

4 Out side fault / External fault withfault message on scroll display as* EARTH LOCK

1. Put HBA on 0, check any abnormality in

auxiliaries, if found so, isolate the defective

auxiliary, again put HBA on 1 and energise the

loco.

2. If there is no abnormality in auxiliaries but

fault massage again comes, put HBA on 0, open

all BL switches, put HPH, HVSL-1&2, HVSI-

1&2, HVMT-1&2, HVRH and HRAVT on 0 (if

HRAVT is not provided, remove CCRA-1,

CCRA-2, CCVT fuses, manually trip MCB near

TFVT) , again put HBA on 1 and energise the

loco.

* If DJ / VCB holds, put one by one auxiliary

switches on normal and close DJ. On putting

particular switch on 1 if DJ trips, put back that

particular switch on 0 and work the train

following relevant precautions.

* If DJ/VCB trips again and comes fault message

again, put all auxiliary switches on normal, put

HSIV on 0 provided on TB panel, press Reset

Push Button provided on SI unit and energise the

loco. Clear block section and inform to TLC. If

Earth Fault Bypass switch or HSIV not provided,

ask for relief loco.

Page 72: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

72

TROUBLE SHOOTING FOR STATIC CONVERTER LOCO DESIGNED BYAUTO METER (KIT2/3)

Duties of Loco Pilot when DJ/VCB trips.

Sr.NoDisplay panel / Indication on

screenDuties of Loco Pilot

1 Input over voltagePut HBA on 0 & again put HBA on 1, energise the loco.

If unsuccessful, ask for relief loco.2 DC Link over voltage

3 Out put over voltage

4 Fuse trip

5 Fan Fault

6 Rectifier Fault

7 Inverter Fault

8 Input / Output over current withfault message on scroll screen asfollows:*AC _ OC – 1* AC _ OC – 2* S Phase _ F

1. Put HBA on 0, check any abnormality in auxiliaries, if

found any abnormality, isolate the defective auxiliary,

again put HBA on 1 and energise the loco.

2. If there is no abnormalities in auxiliaries but fault

massage again comes, put HBA on 0, open all BL

switches, put HPH, HVSL-1&2, HVSI-1&2, HVMT-

1&2, HVRH and HRAVT on 0 (if HRAVT is not

provided, remove CCRA-1, CCRA-2, CCVT fuses,

manually trip MCB near TFVT)

* Put HBA on 1 and close DJ.

* If DJ / VCB hold, put one by one auxiliary switches on

Page 73: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

73

normal and close DJ. On putting particular switch on 1 if

DJ trips, put that particular switch on 0 and work the

train following relevant precautions.

* If DJ trips again and same message shows, ask for

relief loco

9 External Earth Fault withmessage on scroll screen asfollows:* ELD _ FT

1. Put HBA on 0, check any abnormality in auxiliaries, if

any isolate the defective auxiliary, again put HBA on 1

and energise the loco.

2. If there is no abnormality in auxiliaries but fault

massage again comes, put HBA on 0, open all BL

switches, put HPH, HVSL-1&2, HVSI-1&2, HVMT-

1&2, HVRH and HRAVT on 0 (if HRAVT is not

provided, remove CCRA-1, CCRA-2, CCVT fuses,

manually trip MCB near TFVT) , again put HBA on 1

and energise the loco.

* If DJ / VCB hold, put one by one auxiliary switches on

normal and close DJ. On putting particular switch on 1 if

DJ trips, put that particular switch on 0 and work the

train following relevant precautions.

* If DJ/VCB trips again and comes fault message again,

put all auxiliary switches on normal, put HSIV on 0

provided on TB panel, press Reset Push Button provided

on SI unit and energise the loco. Clear block section and

inform to TLC. If Earth Fault Bypass switch or HSIV not

provided, ask for relief loco.

10 Internal Earth Fault with thefollowing message on scrollscreen:ELD _ FT

1. Put HBA in 0 for 2 minutes, put again HBA on 1 and

energise the loco.

* If unsuccessful, ask for relief loco.

Page 74: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

74

TROUBLE SHOOTING FOR STATIC CONVERTER LOCO DESIGNED BYAUTO METER (GENEREC)

Duties of Loco Pilot when DJ/VCB trips.

Sr.No. Display panel / Message on screen Duties of Loco Pilot

1 Input low voltage / Fuse / Fan /Rectifier / Inverter fault / Overtemperature

1. Press Reset Button provided on panel and energise

the loco.

* If unsuccessful, put HBA on 0 & again put on 1 and

energise the loco.

* If unsuccessful, ask for relief loco.

2 Input OV / OCDC link OV / OCAC output OV / OC with thefollowing message on scrollscreen:

* AC _ OC – 1* AC _ OC – 2* S Phase _ F

* Press Reset Button provided on panel and energise

the loco.

* If unsuccessful, put HBA on 0, check any

abnormality in auxiliaries & isolate the defective

auxiliary, again put HBA on 1 and energise the loco.

* IF still found unsuccessful, put HBA on 0, open all

BL switches, put HPH, HVSL-1&2, HVSI-1&2,

HVMT-1&2, HVRH and HRAVT on 0 (if HRAVT is

not provided, remove CCRA-1, CCRA-2, CCVT

fuses, manually trip MCB near TFVT) , again put

HBA on 1 and energise the loco.

* If DJ / VCB holds, put one by one auxiliary

switches on normal position and close DJ. On putting

particular switch on 1 if DJ trips, put back that

particular switch on 0 and work the train following

relevant precautions

* DJ / VCB trips again, ask for relief loco.

3 External Earth Fault with * 1. Press Reset Button provided on SI panel and

Page 75: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

75

message on scroll screen asfollows:ELD _ FT

energise the loco.

* If unsuccessful, put HBA on 0, check any

abnormality on auxiliaries & isolate the defective

auxiliary, again put HBA on 1 and energise the loco.

* If Still found unsuccessful, put HBA on 0, open all

BL switches, put HPH, HVSL-1&2, HVSI-1&2,

HVMT-1&2, HVRH and HRAVT on 0 (if HRAVT is

not provided, remove CCRA-1, CCRA-2, CCVT

fuses, manually trip MCB near TFVT) , again put

HBA on 1 and energise the loco.

* If DJ / VCB holds, put one by one auxiliary

switches on normal and close DJ. On putting a

particular switch on 1 if DJ trips, put back that

particular switch on 0 and work the train following

relevant precautions.

- If DJ/VCB trips again and comes fault message

again, put all auxiliary switches on normal, put HSIV

on 0 provided on TB panel, press Reset Push Button

provided on SI unit and energise the loco. Clear

block section and inform to TLC. If Earth Fault

Bypass switch or HSIV not provided, ask for relief

loco

4 Internal Earth Fault with messageon scroll screen as follows:ELD _ FT

* 1. Press Reset Button provided on SI panel and

energises the loco.

* Put HBA in 0 for 2 minutes, put again HBA on 1

and energise the loco.

* If unsuccessful, ask for relief loco.

Page 76: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

76

TROUBLE SHOOTING FOR STATIC CONVERTER LOCO DESIGNED BYHIND RECTIFIER (HIRECT)

Duties of Loco Pilot when DJ/VCB trips.

Sr.No Display panel / Message on screen Duties of Loco Pilot

1 AC INPUT OK is not glowing 1. Close VCB; ensure OHE voltage is between 16.5

to 31 kv, if it is out of limit, contact with TPC/TLC,

Put HBA on 0 & again on 1 .Close VCB.

2. If unsuccessful, ask for relief loco.

2 Inverter Fault / IVPS / SCR fault * Put HBA on 0 & again put HBA on 1 and

energise the loco.

* If unsuccessful, ask for relief loco.

3 Inverter Fault with message onscroll screen as follows:EARTH FA

1. Put HBA on 0, check any abnormality in

auxiliaries, if found so, isolate the defective

auxiliary, again put HBA on 1 and energise the

loco.

2. If Still found unsuccessful, put HBA on 0, open

all BL switches, put HPH, HVSL-1&2, HVSI-1&2,

HVMT-1&2, HVRH and HRAVT on 0 (if HRAVT

is not provided, remove CCRA-1, CCRA-2, CCVT

fuses, manually trip MCB near TFVT) , again put

HBA on 1 and energise the loco.

3. If DJ / VCB holds, put one by one auxiliary

switches on normal and close DJ. On putting a

Page 77: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

77

particular switch on 1, if DJ trips put that particular

switch on 0 and work the train following relevant

precautions.

4.If DJ/VCB trips again and comes fault message

again, put all auxiliary switches on normal, put

HSIV on 0 provided on TB panel, press Reset Push

Button provided on SI unit and energise the loco.

Clear block section and inform to TLC. If Earth

Fault Bypass switch or HSIV not provided, ask for

relief loco.

1. Positions of HSIV provided on TB panel:1 – Normal

0 – Resistance RSIV is in service (To reduce earth fault leakage current)

2. Positions of HRAVT provided on TB panel:Position Cab Heater Cab Fan Notch Repeater Walkie Talkie Charger

0 Isolate Isolate Isolate Isolate

1 Service Service Service Service

2 Isolate Service Service Service

3 Isolate Isolate Service Isolate.

Page 78: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

78

INSTRUCTION FOR TROUBLE SHOOTING OF STATIC INVERTER

VFD and trouble shooting to be done accordingly. HSIV Switch is provided to by pass earth faultoccurs in auxiliary power circuit.

SINO.

Fault code/ indications Action to be Taken by crew

A SIV fails to startwithout anyindication.

(i) Check CCINV fuse. If melted, replace it.(ii) if CCINV repeatedly melt put HOBA OFF in all

locomotives & replace CCINV fuse.(iii) if again fails to start, trip the loco, put HBA OFF,wait for 2 seconds & try again.

B OHE OUT OFRANGE, (H-3 lampglowing)

If OHE Voltage is not in between 17.5 KV, then waitfor normalization of OHE or contact TLC/TPC.

C Internal fault, rectifierfault , fan fault , fusetrip, etc. (H-2 lampglowing)

Reset the STC by pressing RESET Pus button switchprovided in the STC front cover.If not provided, trip the loco, put HBA OFF , wait for2 seconds and try again.

D Outside fault,External fault, Earthfault etc.(H-4 lampglowing).

(i) check for smoke emission from auxiliary motors,contactors panels, SIV. Ensure all contactor areopen.

(ii) if now abnormalities, close DJ, Resume traction.

(iii) if again SIV trips, remove CCSPM change theswitch position of HRAVT one by one.

Change the position of HCP/ZPV.Close DJ and resume traction.Refer TSD Page no. 57 for isolation of auxiliarymotors in ARNO fitted locomotive.

(iv) if SIV trip again, put HSIV on zero. PressEARTH BY PASS PUSH BUTTON SWITCH,Provided in SIV. Close DJ, resume traction for45 minutes.Observe for any smoke emission on run.If there is a smoke emission from any auxiliarymotor, extinguish the fire by using the fireExtinguisher.

(v) if not rectified ask for assistance.

Page 79: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

79

SINO.

Fault code/ indications Action to be Taken by crew

E SIV fails to start afterputting BLVMT ‘ON’

(i) check CCINV & CCA fuse (both locos in caseof MU) & Replace if melted.(ii) if both are OK, check QSVM relay. If notrectified ask for assistance.(iii) Wedge the QSVM relay & put BLVMT‘ON’ SIV will start along with all blowers.

F Tripping after startingof blower motors.

Refer TSD page no. 63 and trouble shooting willbe done for tripping in operation ‘O’

G CCA melting evenHOBA ‘OFF’

Wedge C101, C102, C103, C105, C106, & C107.Energize the converter and work as per advice ofTLC.Note: wedging of Q118 in rear loco is notrequired for SIV locos during wedging of C105,C106 & C107.

NOTE:(i) HSIV & HRAVT switches are provided on the switch board.(ii) HSIV switch is to be put ‘0’ in case of earth fault in auxiliary circuit when-

(a) the loco motive is stuck up in the middle of block section and to work the trainup to next section for 45 minutes only.

(b) it is not possible to identify & isolate the faulty circuit.(c) Earth bypass push button has been passed in SIV.

(iii) The position of HSIV shall be restored to ‘I’ , After rectification of the faultandentry must be done in the log book by the loco pilot and / or maintenance staff.(iv) SWITCH POSITION OF HRAVT

HRAVT Switch Position Cab Heater Cab Fan Notch Repeater Charger For WalkieTalkie

0 Χ Χ Χ Χ

1 √ √ √ √

2 Χ √ √ √

3 Χ Χ √ Χ(v) If 3-phase MVRF is provided:-(a) During RB : Put MP on “0” and open DJ. Bring MP on “P” and then close DJ.MVRF will stop and MVRF will start working.(b) After RB : Open DJ, bring MP on “0” from “P”, close DJ and resume traction.

Page 80: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

80

TROUBLE SHOOTING FOR UNIFIED STATICCONVERTOR FITTED LOCO

(a) Display of status:fallowing set of status indications are recommended for the driving

crew. The display shall be in from of LED/LED clusters as indicated below:

SN Description LED indication Remark

1. SI Unit OK GreenThe indication is PN, when there isno fault in the SIV

2.Input Voltage inrange

RedThe indication is OFF, when theinput voltage is within the operatingrange.

3. Internal Fault RedThe indication is ON, when faultoccurs inside the SIV.

4. External Fault Red

The indication is ON, when faultoccurs on the input / load includingfaults such as earth fault, Outputsingle phase etc.

5. CHBA OK GreenThe indication is ON (any LSCHBAlamp is OFF) when the batterycharger unit is working.

Following instruction should be followed by the driving crew in respect of the above:

SN Indication Instruction for the driving crew

1. Green LED Indicationof “SI unit OK” goesOFF

This is definite indication of a fault in theSIV. The action to be taken as per the otherindication and fault code displayed.

2. Red LED indication of“Input Voltage inrange” comes ON

ON<17.5 KV VCB will be trip through No voltrelay Q-30.ON> 30 KV VCB will not trip, SIV will trip andLSCHBA glows without VCB tripping (withoutglowing LSDJ) voltage indication will remain onUA meter.The Driver can easily monitor the OHE voltageand this differentiation.Watch the level of OHE Voltage and wait forsome time till OHE voltage becomes normal.Energize the locomotive and work the train.

Page 81: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

81

3. Red LED indication of“Internal Fault” comesON

This indicates that fault is inside the SIV.Normally such fault can not be tackle online, unless the fault is transient. Drivershould trun OFF the battery, turn it ON againand energize the locomotive and ifsuccessful, work the train.

4. Red LED indication of“External Fault”Comes ON

Action should be taken in the followingsequence:1. Isolate the cab heater and cab fan. Restartthe SIV. If successful, work the train.2. If not successful, switch off BLCP andBLVMT. Restart the SIV trips through earthfault, Isolate the faulty motor from MVSIs,MVSLs and MPH. Follow existingtroubleshooting directory and work the train.3. If not successful, switch ON BLVMT.Restart the SIV. If SIV Trip through earthfaults, Isolate the faulty MVMT or MVRH.Follow existing troubleshooting directoryand work the train.5. If not successful switch on BLCP. Restartthe SIV. If SIV trips through earth fault,isolate the faulty MCP, Follow Existingtroubleshooting directory and work the train.5. If not in successful identifying the fault,isolate all lodes connected at the output ofSIV. If SIV trips through earth fault, thefault is inside the SIV.6. Advice TLC accordingly and work thetrain or ask for assistance.

5. Green LED indicationof “CHBA OK” GoesOFF

LSCHBA lamp on the driver desk will alsoglow. Isolate the battery charger, lf loco istripping through SIV.(Manufacturers shallprovide a switch for isolation of the batterycharger) Advice the Traction loco Controllerand work the train till next relief point.

Page 82: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

82

(b) Display of functional parameters:

SN Parameter Displayed As Remark

1. Input voltage Χ Χ Χ

2. Input current Χ Χ Χ

3. Output voltage Χ Χ Χ Line to Line voltage

4. Output current Χ Χ Χ Line Current

5. CHBA voltage Χ Χ Χ

6. CHBA current Χ Χ Χ

Display of fault code:It has been observed that the fault codes of different makes of the

SIVs do not match with each other. Even for the same type of faults the displayed faultcodes are different. Due to different acronyms used by different manufacturers,maintenance staff finds it difficult to troubleshoot. It is therefore decided to make thefault codes displayed in the text form, which is self explanatory as well as easilyunderstandable by the maintenance and operating staff.

In event of a fault occurring in theSIV, the same will be displayed in plain text limited to 20 characters. The fault occurringon the SIV shall be categorized in the following fashion so as to make it understandableto the operating and maintenance staff irrespective of the make of the SIV.

SN Fault displayed as Remark

1. Input fuse Failure In case the input fuse is blown due to high currentdrawn.

2. Input voltage high Input voltage Exceeding upper limit.

3. Input voltage drop low Input voltage drop Below limit

4. DC Link current High Excess current following in the DC bus

5. DC Link voltage high DC Link voltage Exceeds upper limit.

6. DC Link low Voltage DC Link Voltage drop below lower limit.

7. Output current high In case of output high current conditions persisting.

8. Output voltage high Output voltage exceeding upper limit

Page 83: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

83

9. Output voltage low Output voltage drop below lower limit

10. earth fault In event of earth fault at input / output of SIV

11. Unbalance phase Unbalance / single phasing at the output

12. Blower fault Failure of blower cooling

13. CHBA Fault Charger fault

14. Input current high In case of input high current conditions persisting.

15. Rectifier fault In event of fault in Rectifier section.

16. Inverter fault In event of fault in Inverter section

17. Chopper Fault Chopper section faulty.

18. Over Temperature Any Temperature sensing devise operated in theRectifier & Inverter section

19. Power supply Fault In event of failure of any of the electronic/controlpower supply.

20. Chopper current high Chopper section current exceeds upper limit

21. CHBA current high Battery charger current limit exceeded

22. CHBA voltage high Charger voltage exceeding upper limit

23. CHBA voltage low Charger voltage drops below lower limit

24. CHBA temp high Charger temperature exceeds upper limit

1. The fault display on the VFD/LCD will appear in case a fault occurs in the SIV dueto internal / external causes.

2. The fault in plain 20 characters text will appear on the display.3. the faults will remain displayed till the operator / driver acknowledges them by

pressing the acknowledgement key.4. Once acknowledges button is pressed or 110V dc battery power supply to converter

is switch OFF & ON, The fault display will be reset and parameters will bedisplayed.

(i) ARNO Loco leading and SIV Loco trailing :In case ,ARNO Loco in leading position, as per the instruction ARNO Loco LP toswitch ‘OFF’ BLVMT and after starting of ARNO loco pilot then Put ‘ON’ BLVMTwith this condition :-

When loco pilot closes DJ leading loco ARNO will start after 3.5 secs. Andstarting time of SIV loco is approximately 6 seconds.As and when BLVMT willswitch ‘ON’ the trailing loco,which is SIV,the SIV will switch ‘OFF’ and after 2

Page 84: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

84

seconds of delay,the SIV will start again and take complete 8 seconds time to fullvoltage.

In this condition,if loco pilot takes notches beyond 5th notch,the DJ of trailingloco will trip as the air flow relay of QVMT-1 or QVMT-2 or QVRH are not pickedup.The loco pilot shall be counseled to start taking notches only after extinguishing ofthe LSCHBA indication .

(ii) SIV loco leading and ARNO loco trailingThe instruction to loco pilot for SIV loco ,before closing DJ BLVMT switchshould be ‘ON’ for soft start.In this condition ,when DJ closes the SIV locoblower motor starts with soft start mode and ARNO loco’s blower I;e MVRH,MVMT-1 &MVMT-2 will start after closing Q100 relay.

While working MU locos locopilots shall be advised:-(i) To release the BLRDJ switch as per the practice being followed in the

case of ARNO fitted locomotives,irrespective of one or other locomotiveis fitted wih ARNO or SIV.

(ii) To start taking notches only after extinguishing of the LSCHBA indicationto ensure that loco with SIV does not trip through air flow relays.

Page 85: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

85

MICROPROCESSOR LOCOTROUBLE SHOOTING FOR MICROPROCESSOR LOCO DESIGNED BY

MEDHA

If any fault message comes on display unit with buzzer, note the fault message and then press

“Ack”Sr.No. Fault message on display unit Duties of Loco Pilot

1C118 N/C Contact Fail

Ensure C118 Opening Do not Press BLRDJCheck C118 is opened fully.

2

C118 Stuck up

Ensure opening of C118

Release BLRDJ if pressed

Release BLRDJ and ensure C118 is

opened fully

3

No Tension

Wait for OHE Voltage

Retry to close DJ

Trouble shoot as per TSD of WAG5

4OHE low / No Voltage

Apply Emergency BrakeTrouble shoot as per TSD of WAG5

5DJ tripped Via QOP-1

Reset QOP-1 isolate faulty TM by HMCS-1

Trouble shoots as per WAG-5 TSD.6

DJ tripped Via QOP-2

Reset QOP-2 isolate faulty TM by HMCS-2

7

DJ tripped Via QOA

Put HQOA on 0

Check all Auxiliary / Heater, follow TSD

8 DJ tripped Via QRSI-1

Reset QRSI-1 isolate faulty TM by HMCS-1 Follow TSD inform TLC

Page 86: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

86

9 DJ tripped Via QRSI-2

Reset QRSI-2 isolate faulty TM by HMCS-2

Follow TSD inform TLC Trouble shoots as per WAG-5 TSD.

10 DJ tripped Via QLM

Check transformer / GR oil splashing.

11

DJ tripped Via QVSL-1

Check MVSL-1 if normal Put HVSL-1 on 3

Resume Traction

Put corresponding switch on 3, close DJ

and check corresponding auxiliary.

- If auxiliary is working, work the train.

- If auxiliary is not working, isolate the

particular auxiliary and work the train

following relevant precautions.

12

DJ tripped Via QVSL-2

Check MVSL-2 if normal Put HVSL-2 on 3

Resume Traction

13

DJ tripped Via QVMT-1

Check MVMT-1 if normal Put HVMT-1on 3

Resume Traction

14

DJ tripped Via QVMT-2

Check MVMT-2 if normal Put HVMT-2on 3

Resume Traction

15Check MVRH if normal Put HVRH on 3

Resume Traction

16

DJ tripped Via QVSI-1

Check MVSI-1 if normal Put HVSI-1on 3

Resume Traction

17

DJ tripped Via QVSI-2

Check MVSI-2 if normal Put HVSI-2on 3

Resume Traction

18

DJ tripped Via QPH

Check TFP oil level frequently

Put HPH on 0 & clear block section.

19 DJ tripped due to GR stuck between notch

Bring GR to 0 manually.

Clear block section manually.

Bring GR to 0 manually, close DJ and

clear block section by manually control

of GR

20 DJ tripped due to Low / No ARNO voltage Inform to TLC and ask for relief loco.

21 DJ tripped Via QLA.

Isolate faulty auxiliary machine, if fault

exists make loco dead and inform to TLC. Trouble shoots as per WAG-5 TSD.

22 DJ tripped Via QPDJ Check RS pressure

Start CPA to build up pressure.

Page 87: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

87

23QVRF not working

Do not use Dynamic Braking.Do not use DBR.

24ICDJ through QOP-1 DroppedPut HQOP-1 OFFOn running condition watch HTC

Trouble shoots as per WAG-5 TSD.

25ICDJ through QOP-2 DroppedPut HQOP-2 OFFOn running condition watch HTC

26ICDJ through QOA DroppedPut HQOA on 0Check auxiliary machines

27ICDJ through QLM DroppedCheck HT compartment for Oil splashing.Inform to TLC.

28 ICDJ through QRSI-1 dropped

29 ICDJ through QRSI-2 dropped.

30ICDJ through QLA droppedCheck ARNOInform to TLC

31ICDJ through QPDJ droppedCheck RS pressure / leakageStart CPA to build up pressure

Trouble shoots as per WAG-5 TSD.

32Reverser are neither in F or RSet the Reverser manuallyResume traction

Trouble shoots as per WAG-5 TSD.

33CTFs are neither in T nor BSet the CTFs manually on T side only.Resume traction.

Trouble shoots as per WAG-5 TSD.

34GR not in ZeroPut GR at 0 manuallyClose DJ

Bring GR to 0 manually and close DJ

35 Brake applied through IPDo not use DBR

Close IP cut out cock and do not use

DBR

36 Auto regression Via RGEBIf not Brake applied check for leakage

Ensure BP pressure is 5 kg/cm2 intact.

37Auto regression Via QDPress BPQD / Resume traction

- If auto regression takes place due towheel slip, press QD and apply sanders.- If auto regression takes place due totraction motor defects, isolate defectivetraction motor.

38Auto regression Via TM over voltageCheck TM voltage

Work the train on lower notches andinform to TLC

39Braking Fault SWC OperatedDo not use Loco Brake during DB

Ensure SA-9 is in released and do notuse DBR

40 Working with One CPU Resume traction and inform to TLC.41 EEPROM Failed Resume traction and inform to TLC.

Page 88: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

88

42 Other CAB display fail Resume traction and inform to TLC.43 Loco in LT STATUS MESSAGE during LT testing

44

Press BLDJSelect PantoPress BLRDJ

After energising loco STATUSMESSAGE

45HVMT-1 in Position 0L-1, L-2 and L-3 cut off Half poweravailable

After isolating MVMT-1, STATUSMESSAGE

46HVMT-2 in Position 0L-4, L-5 and L-6 cut off Half poweravailable

After isolating MVMT-2, STATUSMESSAGE

47HVSI-1 in Position 0L-1, L-2 and L-3 cut off Half poweravailable

After isolating MVSI-1, STATUSMESSAGE

48HVSI-2 in Position 0L-4, L-5 and L-6 cut off Half poweravailable

After isolating MVSI-2, STATUSMESSAGE

49 Reverser not as per MPJ position Trouble shoots as per WAG-5 TSD50 CTFs not as per MP position Trouble shoots as per WAG-5 TSD

51C-145 Open HMCS-1 / 2 not in 1Do not use DBR

Do not use DBR

52DBR Overheating or QF / QE operatedDo not use DBR

Do not use DBR

53 DJ tripped via DJ FB failBuild up RS pressureIf unsuccessful, inform to TLC / ask forrelief loco

54Battery charger Out put failCheck CHBAClear block section

Trouble shoots as per WAG-5 TSD

55ICDJ through C-107 Feed back failInform TLC

Put HBA on 0 and check C-107 isopenedOperate C-107 few times manually andtry to close DJIf unsuccessful, inform to TLC.

56ICDJ through C-106 Feed back failPut HVMT-2 on 0Clear section, inform TLC

Put HBA on 0 and check C-106 isopenedOperate C-106 few times manually andtry to close DJIf unsuccessful, put HVMT-2 on 0, clearblock section and inform to TCL.

57ICDJ through C-105 Feed back failPut HVMT-1 on 0Clear section, inform TLC

Put HBA on 0 and check C-105 isopenedOperate C-105 few times manually andtry to close DJIf unsuccessful, put HVMT-1 on 0, clearblock section and inform to TCL.

Page 89: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

89

58 GR stuck up on NotchesPut GR on 0 manually

Bring GR to 0 manually and close DJ

59DJ tripped via C-107 Feed back failInform to TLC

Put HBA on 0 and check C-107 isopened fullyOperate C-107 manually few times andtry to close DJIf unsuccessful, inform TLC

60DJ tripped via C-106 Feed back failPut HVMT-2 on 0Clear section and inform to TLC

Put HBA on 0 and check C-106 isopened fullyOperate C-106 manually few times andtry to close DJIf unsuccessful, put HVMT-2 on 0, clearsection and inform to TLC

61DJ tripped via C-105 Feed back failPut HVMT-1 on 0Clear section and inform to TLC

Put HBA on 0 and check C-105 isopened fullyOperate C-105 manually few times andtry to close DJIf unsuccessful, put HVM1-2 on 0, clearsection and inform to TLC

62 DJ tripped Via C118 N/C contact failCheck C118 is fully opened.If unsuccessful, ask for relief loco

63 ARNO not picking up Inform to TLC / ask for relief loco64 TM voltage channel Noisy Resume traction and inform to TLC.65 V965 voltage channel noisy Resume traction and inform to TLC.66 ARNO voltage channel noisy Resume traction and inform to TLC.67 User changed configuration / Loco No. Resume traction. STATUS MESSAGE

68Communication Link Display in Cab-2fail

Resume traction and inform to TLC

69Communication Link Display in Cab-1fail

Resume traction and inform to TLC

70 RTC Fail Resume traction and inform to TLC71 V 965 Channel fail Inform to TLC / Ask for relief loco72 ARNO channel fail Inform to TLC / Ask for relief loco

73 TM voltage channel failQ-20 will not energise, work the train byobserving Voltmeter and inform to TLC.

74 Auto – regression via ACP Reset ACP and work the train

75 BPAR put in bypassAfter putting HPAR on 0, STATUSMESSAGE

76 BPAR restoredAfter putting HPAR on 1, STATUSMESSAGE

Page 90: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

90

TROUBLE SHOOTING FOR MICROPROCESSOR LOCO DESIGNED BYSTESALIT (FDCS-9648)

Duties of Loco Pilot when DJ/VCB tripsSr.No. Display panel / Message on screen Duties of Loco Pilot

1 C-118 N/C Contact Fail Check C-118 is opened fully

2 C-118 Stuck Up Release BLRDJ and check C-118 is opened fully.3 OHE not available when DJ closed Trouble shoots as per WAG-5 TSD4 No OHE when Loco Running Trouble shoots as per WAG-5 TSD5 DJ tripped via QOP-1 Trouble shoots as per WAG-5 TSD6 DJ tripped via QOP-2 Trouble shoots as per WAG-5 TSD7 DJ tripped via QOA Trouble shoots as per WAG-5 TSD8 DJ tripped via QRSI-1 Trouble shoots as per WAG-5 TSD9 DJ tripped via QRSI-2 Trouble shoots as per WAG-5 TSD

10 DJ tripped via QLM Trouble shoots as per WAG-5 TSD11 DJ tripped via QVSL-1

Put corresponding switch on position 3, close DJ andfrequently check proper working of auxiliary.- If auxiliary is working, work the train.- If auxiliary is not working, isolate the correspondingauxiliary and work the train by taking precautions.

12 DJ tripped via QVSL-213 DJ tripped via QVMT-114 DJ tripped via QVMT-215 DJ tripped via QVRH16 DJ tripped via QVSI-117 DJ tripped via QVSI-218 DJ tripped via QPH19 DJ tripped due to GR Stuck

Between NotchBring GR to 0 manually, close DJ and clear block sectionby manual control of GR.

20 DJ tripped due to Low or NoARNO Voltage.

Inform to TLC / Ask for relief loco.

21 DJ Tripped via QLA Trouble shoots as per WAG-5 TSD22 DJ Tripped via QPDJ Check RS pressure, if less build up pressure by MCPA23 DJ Tripped via QVRF Do not use DBR24 ICDJ due to QOP-1 Dropped Trouble shoots as per WAG-5 TSD25 ICDJ due to QOP-2 Dropped Trouble shoots as per WAG-5 TSD

Sr.No. Display panel / Message on screen Duties of Loco Pilot

26 ICDJ due to QOA Dropped Trouble shoots as per WAG-5 TSD

Page 91: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

91

27 ICDJ due to QLM Dropped Trouble shoots as per WAG-5 TSD28 ICDJ due to QRSI-1 Dropped Trouble shoots as per WAG-5 TSD29 ICDJ due to QRSI-2 Dropped Trouble shoots as per WAG-5 TSD30 ICDJ due to QLA Dropped Trouble shoots as per WAG-5 TSD31 ICDJ due to QPDJ Dropped Trouble shoots as per WAG-5 TSD32 Reverses are Neither in F nor in R Trouble shoots as per WAG-5 TSD33 CTFs are Neither in T Nor in B Trouble shoots as per WAG-5 TSD34 GR Not in Zero Bring GR to 0 manually and close DJ35 Brake Applied Through IP Close IP cut out cock. Do not use DBR36 Auto Regression Via RGEB Ensure BP pressure is 5 kg/cm237 Auto Regression Via QD - If auto regression takes place due to wheel slip, press

BPQD and apply sanders.- If auto regression takes place due to TM defective,isolate defective traction motor and work the train.

38 Auto Regression Via TM OverVoltage

Work the train on lower notches and inform to TLC.

39 Braking Fault. SWC Operated Ensure SA-9 is in release position and do not use DBR40 Working with one CPU Inform to TLC41 System Error Resume traction and inform to TLC42 Other Cab display fail Resume traction and inform to TLC43 Loco in LT During LT Testing STATUS MESSAGE44 Auto Regression Via ACP Reset ACP45 HVMT-1 in Position 0 While isolating MVMT-1 STATUS MESSAGE46 HVMT-1 in Position 2 While putting HVMT-1 on position 2 STATUS

MESSAGE47 HVMT-2 in Position 0 While isolating MVMT-2 STATUS MESSAGE48 HVMT-2 in Position 2 While putting HVMT-2 on position 2 STATUS

MESSAGE49 HVSI-1 in Position 0 While isolating MVSI-1 STATUS MESSAGE50 HVSI-1 in Position 2 While putting HVSI-1 on position 2 STATUS

MESSAGE51 HVSI-2 in Position 0 While isolating MVSI-2 STATUS MESSAGE52 HVSI-2 in Position 2 While putting HVSI-2 on position 2 STATUS

MESSAGE53 Reversers Are Not as per MPJ

positionTrouble shoots as per WAG-5 TSD

54 CTFs Are Not as per MP position Trouble shoots as per WAG-5 TSD55 C 145 Open HMCS-1/2 Not in 1 Do not use DBR56 C 145 Open DBR overheated Do not use DBR57 Auto Regression Via QF/QE Do not use DBR58 Battery Charger Output Fail Trouble shoots as per WAG-5 TSD59 J Forward Feedback Fail Manually operate J-1, J-2 few times60 J Reverse Feedback Fail Manually operate J-1, J-2 few times

Sr.No. Display panel / Message on screen Duties of Loco Pilot

61 CTF Traction Feedback FailManually operate CTF-1, 2 & 3 few times and put onTraction side

62 CTF Brake Feedback Fail Manually operate CTF-1, 2 & 3 few times and put on

Page 92: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

92

Traction sideDo not use DBR

63 ICDJ through C-107 Feedback failPut HBA on 0 and check C-107 is opened.Manually operate C-107 few times and try to close DJIf unsuccessful, inform to TLC

64 ICDJ through C-106 Feedback fail

Put HBA on 0 and check C-106 is opened.Manually operate C-106 few times and try to close DJIf unsuccessful, HVMT-2 on 0, clear section and informto TLC

65 ICDJ through C-105 Feedback fail

Put HBA on 0 and check C-105 is opened.Manually operate C-105 few times and try to close DJIf unsuccessful, HVMT-1 on 0, clear section and informto TLC

66 DJ tripped via DJ FB failCheck RS pressure.If unsuccessful, inform to TLC / Ask for relief loco.

67DJ Feedback found close beforeDJ is closed

Inform to TLC / Ask for relief loco.

68 Auto Regression via DBR pressureswitch

Do not use DBR

69 UCDJ due to Q-44 operated Inform to TLC / Ask for relief loco.

70 BRLDJ released before C-118 isenergised

Press BLRDJ 3-4 seconds

71 UCDJ due to feedback failed Inform to TLC / Ask for relief loco.

72DJ tripped due to GR stuck onNotches

Bring GR to 0 manually, close DJ and clear blocksection by manual control of GR

73 Auto regression via Q-50Clear block section by manual control of GR and informto TLC

Note: If any fault message comes on display unit, trouble shoot as per fault message. If trouble is notrectified, before asking relief loco, Loco Pilot do as follows

a. Put HOBA in OFF and try to rectify the trouble.b. Switch off Battery for 3 minutes and try to rectify the trouble.

Page 93: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

93

TROUBLE SHOOTING FOR MICROPROCESSOR LOCO DESIGNED BYADCFDS

Duties of Loco Pilot when DJ/VCB trips

Sr.No. Display panel / Message on screen Duties of Loco Pilot

1 DJ Tripped via QVSL-1Put corresponding switch on position 3, close DJ andcheck the working of auxiliary frequently- If auxiliaries are working, work the train.- If any auxiliary is not working isolate thecorresponding auxiliary and work the train followingrelevant precautions.

2 DJ Tripped via QVSL-23 DJ Tripped via QVMT-14 DJ Tripped via QVMT-25 DJ Tripped via QVRH6 DJ Tripped via QVSI-17 DJ Tripped via QVSI-28 DJ Tripped via QPH

9DJ Tripped due to GR Stuck BetweenNotches

Bring GR to 0 manually, clear block section bymanual control of GR.

10 DJ Tripped via QOP-1 Trouble shoots as per WAG-5 TSD11 DJ Tripped via QOP-2 Trouble shoots as per WAG-5 TSD12 DJ Tripped via QOA Trouble shoots as per WAG-5 TSD13 DJ Tripped via QRSI-1 Trouble shoots as per WAG-5 TSD14 DJ Tripped via QRSI-2 Trouble shoots as per WAG-5 TSD15 DJ Tripped via QLM Trouble shoots as per WAG-5 TSD16 DJ Tripped via QLA Trouble shoots as per WAG-5 TSD17 DJ Tripped via Q-30 Trouble shoots as per WAG-5 TSD

18 Auto Regression Via Wheel-Slip

- If auto regression takes place due to wheel slip,press BPQD and apply sanders.- If auto regression takes place due to TM defective,isolate defective traction motor and work the train.

Note: If any fault message comes on display unit, trouble shoot as per fault message. If trouble isnot rectified, before asking relief loco, Loco Pilot do as follows

c. Put HOBA in OFF and try to rectify the trouble.d. Switch off Battery for 3 minutes and try to rectify the trouble.

Page 94: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

94

MICROPROCESSOR BASED LOCO

TROUBLE SHOOTING

ICDJ:

1. Check Add. CCBA, CCBA, CCPT & CCCPU. If any fuse melts, renew the same. If again fuse

melts, keep HOBA in OFF and renew the fuse.

2. Ensure MR/RS pressure is above 8Kg/cm2.

3. Check safety relay target, if any relay energized, act according to TSD.

4. Ensure BA voltage is above 90 Volts.

5. Ensure GR on ‘0’

6. Try to close DJ with BP2DJ.

7. Keep HQOP 1 in OFF, HQOP 2 in OFF, and HOBA in OFF and try.

8. Try from rear cab.

9. Keep HBA on ‘0’, wait for 3 minutes and try to energise the locomotive.

10. In ARNO provided locos check C118 contactor closing or not.

TLTE:

1. If LSB glowing ensure J1, J2 and CTFs are in proper position.

2. Ensure SMGR pressure is between 2.5 to 3.5Kg/cm 2.

3. Ensure RGEB 2 COC is in open condition.

4. Try with EEC operation.

5. Try from rear cab.

6. Keep HOBA in OFF and try.

Try to clear the section by manual operation of GR.At times, the fault diagnostic systems

are giving erratic information leading to wrong guidance since they are not stabilized fully.

Hence Loco Pilots should follow the normal procedure of troubleshooting.

Page 95: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

95

ANNEXURE-AVIGILANCE CONTROL DEVICE (VCD)

Operating Instructions of VCD for loco pilotDo’s Don’tsAfter BL key is unlocked, check for ‘VCD OK’LED signal on VCD display panel.If thatLED glows it is an indication that VCD in working condition and it is in service.If VCD indicates ‘VCD Fault’ then by pass VCD and record in loco log book.Always keep VCD in service Don’t By pass VCD with out proper reasonAlways keep IP valve in service Don’t close IP Valve Cock.If IP valve is closed

VCD indicates as ‘BP-FED-Fault’ at the time oftest/penalty brake.

Always act in time (<76 secs.)toacknowledge VCD in vigilancecycle(60 secs.)+or flash cycle(8secs.),by any of these methods

a)By any ACK push button orb) Operate any horn switch orc)Operate sanders ord)Notches up/down ore)Brakes applied through A-9

or SA-9

Don’t press ack.push button continuously for morethan 60 sec.It will lead to application of penaltybrake through IP valve with auto regression.

Note: 1.If brakes are applied by loco pilot through A-9 or SA-9 there is no need toacknowledge VCD as it is in vigilance suppression mode.

2. When BL key is unlocked VCD will apply test brake as soon as BP pressurereaches 4.5 kg/cm2 to check whether the IP valve is in service or not

Penalty brake : If VCD is not acknowledged during the above period, it applies penaltybrake for 30 secs. through IP Valve with auto regressionProcedure to Release Brake : After extinguish of yellow flashing LEDs on VCDdisplay panel, keep MP in ‘0’ position and press any VCD ack pueh button switch torelease brakes.Bypass VCD :If VCD indicates”VCDFault” on its display panel or behaves erraticallythan bypass VCD and record in log book.How to Bypass : VCD bypass switch is available only in VCD master on its right side.Brake and open the seal & remove cover to access bypass switch and put it to ‘off’.

Page 96: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

96

ANNEXURE-B

WORKING WITH THE LEADING LOCO IN MU/CONSIST WHEN LEADINGLOCO DEFECTIVE TO CLEAR BLOCK SECTION ONLY

SI.No.

Type of defects onLeading loco

Action to be taken by theDriver

Precautions to be observed

Ensure Load Permits1 ICDJ Close BLDJ. Press

BLRDJ Release BLRDJafter 3 - 5 sees ResumeTraction

Ensure ZPT on pos -1 or 2Pantos of both locos areraised

2A.B.

TLTE - A1&A2 both are0. GR not progressingat all GR isprogressing.

Put ZSMS switch onposition - 0 or 1. ResumeTraction with MP or EEC,operating from leadingloco.

Ensure Q49 and Q52 are De-energised. If energised.Wedge Q49 and Q52 in De -energised condition on allLocos

3 GR Safety Valve Blown Isolate VEPT by closingboth cut out cocks .closeBLDJ. Press BLRDJRelease BLRDJ after 3 -5 secs. Resume TractionClear Block Section.

Ensure fire, if any is properlyextinguished. Ensure there isSmoke Emission due to oilspread near GR. Ensure bothPantos are Lowered onLeading Loco.

4 A If DJ trips through QGR Check for anyabnormality near GR If noabnormality is noticed.Reset the relay target.Close DJ ResumeTraction.

Ensure there is no oil spreadnear GR. Oil Level in the GRoil gauge is between + 20 and- 20 degrees.

4 B If DJ trips through QGRagain.

Isolate VEPT both cut outcocks Close BLDJ. PressBLRDJ Release BLRDJafter 3 - 5 sees ResumeTraction. Clear BlockSection.

Ensure both pantos areLowered on Leading Loco.

5 Smoke Emission FromARNO

Take Safety Measures.Extinguish the Fire.Isolate VEPT both cut outcocks. Close BLDJ. PressBLRDJ Release BLRDJafter 3 - 5 secs. ResumeTraction.

Ensure both Pantos areLowered on Leading Loco.

6 MR air Hose Pipe Burst Isolate MR Air Hose Pipecutout cocks on bothLocos. Close BLDJ.Press BLRDJ ReleaseBLRDJ after LSCHBAgoes out. ResumeTraction.

Ensure Pressure is more than8 kg. If Less, Build up RSpressure individually on bothLocos.

Page 97: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

97

ANNEXURE-C

TECHNICAL DETAILSSYMBOL EQUIPMENT SPECIFICATIONRTPR Voltage Stabiliser Input 420 Volts AC±20% (SPECIFIED)

Out put 380 Volts AC±20% (ACTUAL)i. 32 Volts for head lights.ii. 24 Volts for instrument, lights.iii. 16 Volts for dimmer.

Head light bulb 32 Volts - 250 watts.DC-DC DC-DC convertor Input 110 Volts DC

Output 24 volts DCHead light bulb 24 volts(100W/90W)

VT Cab fan Input 110VAC±22V2%RA Cab heaters Input 420 Volts AC±20% (SPECIFIED)

380 Volts AC±20% (ACTUAL)LC Cab lights Input 110VD.C.LE Entrance lights Input 110VD.C.LM Corridor & HT

Compartment lights Input 110VD.C.LS Signalling lights Input 110VD.C.FL Flasher lights Input 110 D.C.SPM Speedometer Input 110 VD.C. (Stabiliser)

Out Put 60 V (Electronic SPM)24 V (Hasler Berne)36 V (Autometers)

Page 98: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

98

NOMENCLATURE OF RELAYSSL. NO. SYMBOL FUNCTION1. QLM High Voltage Over Load Relay2. QRSI Over Load Relay for Rectifier3. QE Over Load Relay for Braking Excitation4. QF Over Load Relay for Braking5. QOP Earth Fault Relay for Power Circuit6. QOA Earth fault relay for Auxiliary Circuit7. QD Wheel Slip Detection Relay. (Current Differential)8. QCVAR ARNO starting phase Relay9. QPH Relay for Oil Pump for Transformer10. QPDJ Pressure Switch for DJ11. QVRH Air Flow Relay for Transformer Oil Cooling Blower Motor12. QVMT Air Flow relay for Traction Motors Blower13 QVSL Air Flow Relay for Smoothing Reactor Blower Motor14. Q-20 Over Voltage Relay for Traction Motors15. Q-30 No Voltage Relay16. Q-44 Protection Relay Rectifier Blower and GR17. Q-45 DJ Closing Relay18 Q-46 GR Monitoring Relay19 Q-48 Wheel Slip Protection Relay. (Time lag & Signalling)20 Q-49 GR Synchronizing Relay21 Q-50 Relay for Reversor and CTF22 Q-51 Relay for Auto-Regression23 Q-52 Notch to Notch Relay24 QV-60 Relay for LSDJ25 QV-61 Relay for LSCHBA26 QV-62 Relay for LSGR27 QV-63 Relay for LSRSI28 QV-64 Relay for LSB29 Q-100 Relay for Auxiliary Working30 Q-118 Relay for Auxiliary Protection31 QSIT Protection Relay for SIV32 QCON SI on relay33 QSVM Relay for TM Blower starting34 QVCD VCD relay35 QTD 105 Time delay on relay for C10536 QTD 106 Time delay on relay for C10637 Q119 Relay for unloader valve38 QTD 101 Time delay on relay for CPs39 QFL Relay for Flasher light40 QPR-1 Time delay on relay for flasher light41 QVSOL Relay for fault indication in trailing loco

Page 99: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

99

PROGRAMME SWITCHES-WAM-4. WAG-5 & WAG-7 LOCOS

SWITCH0

POSITIONI II III

1. HPH MPH ISOLATED SERVICE ISOLATED SERVICEQPH ISOLATED SERVICE SERVICE ISOLATED

2. HVRH MVRH ISOLATED SERVICE ISOLATED SERVICEQVRH ISOLATED SERVICE SERVICE ISOLATED

3. HVMT-1-2 MVMT1-2 ISOLATED SERVICE ISOLATED SERVICEQVMTI-2 ISOLATED SERVICE SERVICE ISOLATED

4. HVSL1-2 MVSL1-2 ISOLATED SERVICE ISOLATED SERVICEQVSL1-2 ISOLATED SERVICE SERVICE ISOLATED

5. HVSI1-2 MVS11-2 ISOLATED SERVICE ISOLATED SERVICEQVS11-2 ISOLATED SERVICE SERVICE ISOLATED

0 1 Position - 0 indicates6. HBA ISOLATED SERVICE7. HQOA ISOLATED SERVICE BYPASSING QOA8. ZCPA, OFF

(ISOLATED)ON (SERVICE)

9. HQCVAR ISOLATED SERVICE BY PASSING QCVAR10. HCHBA ISOLATED SERVICE BY PASSING CHBA11. HOBA OFF ON OFF BY PASSING RHOBA.

(ISOLATED) (SERVICE)12. HQOP 1-2 OFF

(ISOLATED)ON(SERVICE)

OFF BY PASSING RHQOP.

13 HPAR ISOLATE SERVICE Q51 BYPASSING IN MICROPROCESSED LOCO

14 HSIV ISOLATE SERVICE EARTH FAULT BY PASS SWITCH IN SIV LOCO

Page 100: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

100

APPLICATION ON WAG-5 LOCOS 23385 ONWARD ONLY

Symbol Conditionof/L/Cont

No. ofTM

isolated

Indicationvolt Meter

Amp Meter QD Operation

HMCS1-I L1,L2, L3closed

NIL UMT1 deviate A-1 deviate QD1 in Service

HMCS1-II L1 open TM1 UMT1 Notdeviate

A-1 deviate QD1 in Service

HMCS1-III L2 open TM2 UMT1 deviate A-1 deviate QD1 supressedHMCS1-IV L3 open TM3 UMT1

deviateA-1not deviate

QD1 supressed

HMCS2-I L4, L5,L6 closed

NIL UMT2,deviate

A-2,deviate

QD2 in Service

HMCS2-II L4 open TM4 UMT2deviate

A-2 notdeviate

QD2suppressed

HMCS2-III L5 open TM5 UMT2 deviate A-2 deviate QD2 insuppressed

HMCS2-IV L6 open TM6 UMT2 notdeviate

A-2 deviate QD2 in Service

CANTILEVER-PARTS:

POSITION. ISOLATION OF TM. VOLT METER/AMP METER INDICATION. QD ACTIONFOR ALL WAG-5 LOCOS UPTO 23384

Symbol Conditionof/L/Cont

No. of TMisolated

Indicationvolt Meter

Amp Meter QD Operation

HMCS1-I L1,L2, L3closed

NIL UMT1 deviate A-1 deviate QD1 in Service

HMCS1-II L1 open TM1 UMT1 Notdeviate

A-1 deviate QD1 supressed

HMCS1-III L2 open TM2 UMT1 deviate A-1 deviate QD1 in ServiceHMCS1-IV L3 open TM3 UMT1 deviate A-1 not deviate QD1 supressedHMCS2-I L4, L5, L6

closedNIL UMT2, deviate A-2, deviate QD2 in Service

HMCS2-II L4 open TM4 UMT2 Notdeviate

A-2 deviate QD2 supressed

HMCS2-III L5 open TM5 UMT2 deviate A-2 deviate QD2 in ServiceHMCS2-IV L6 open TM6 UMT2 deviate A-2 not deviate QD2

suppressed

Page 101: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

101

PARTS1. Mast fitting for hook insulator. 2. Stay tube insulator3. Stay tube arm 4.Stay tube sleeve5. Tube cap 6.Mast bracket fitting7. Bracket tube insulator 8.Register arm hook9. Bracket tube 10.Register arm dropper11. Tube cap 12.Anti wind clamp13. Register eye piece assembly. 14. Drop bracket

15. Steady arm hook 16.Steady arm swivel17. Steady arm 18.Contact wire19. Contact wire swivel clip 20.Catenary wire.

Page 102: TROUBLE SHOOTING DIRECTORY FOR AC …...When ever HOBA is placed in OFF position during trouble shooting in one of the loco in MU/Consist, HOBA of other locos also to be kept in OFF

102

PANTO PARTS ON LOCO ROOFINDEX

1. BASE FRAME.2.3.4.

BALI BEARING.HORIZONTAL SPINDLE.

5. LOWER ARAL.6. CENTRAL ARTICULATION.7. TUBES.8. TUBE.9. THRUST ROD.10. FIXED POINT.11. TRANSVERSAL TUBE.12. SLEEVES.13. SHANK.14. TRANSVERSAL TUBE END15. SPRING BOX.16. ROD.17. SPRING.18. BALANCING MEMBER.19. ARMS.