trumpf truheat mf series 3000 7000 - trumpf gmbh + co. kg | … · 2018. 6. 12. · truheat mf...
TRANSCRIPT
TruHeat MFSeries 3000 / 5000 / 7000
Spot-on performance for heating efficiency second to none.
Flexibel power for high efficiency.TruHeat MF Series 3000 / 5000 / 7000.
Benefits
Easily integrates into new or existing systems Ready for worldwide use Eliminates setup-time for capacitor changeovers,
improves productivity and process stability Ideal for temperature controlled processes High productivity and constant process results Easy to confi gure and to operate
Features
Extremely compact design featuring a high power density Wide mains voltage range Parallel oscillating circuit ensures quick process adaptation
Process power control from almost 0 percent to 100 percent Approved reliability Advanced user interface
TruHeat MF Series 3000 / 5000 / 7000 is a family of powerful and extremely versatile medium frequency generators for induction heat-ing applications. Specifically designed for high performance pro-cesses, these generators are offered in a wide variety of configura-tions and parameters. Individual models are available with an output power of 10 Kilowatt (kW) to 250 kW over a frequency range of 3 kilohertz (kHz) to 200 kHz. They can be operated with mains volt-ages between 380 Volts (V) and 480 V, for ease of use all over the world. The used parallel circuit technology enables a wide range of applications. Operating frequency and output power can be quickly adapted. The broad impedance matching range allows work pieces of various shapes to be treated with consistent quality.
TruHeat MF Series 3000 / 5000 / 7000 handles a variety of applica-tions. No matter if traditional or hightech. Such as epitaxy and crystal growing, hardening, melting, soldering or annealing processes. The different series enable easy integration into existing systems or facili-ties where space may be limited. With maximum output voltages of 300 V or 600 V, the TruHeat MF Series 3000 / 5000 / 7000 offers an additional parameter for easy process adaption. Power can be adju-sted from 0 percent to 100 percent for precise and wide range pro-cess temperature control. Advanced user interfaces and constant process results make the TruHeat MF Series 3000 / 5000 / 7000 to an versatile and reliable partner.
W h i t e h o t i n s e c o n d s . S u s t a i n e d f o r m o n t h s :Tr u s t e d T R U M P F H ü t t i n g e r i n d u c t i o n t e c h n o l o g y.
Output Parameters
Output Power 10 kW, 20 kW, 30 kW, 40 kW
Output Frequency 5 kHz – 30 kHz20 kHz – 100 kHz20 kHz – 200 kHz1
Max. Output Voltage 300 V, 600 V
Mains Input
Mains Voltage 3 x 400 V – 10 % bis 3 x 480 V + 10 %
Mains Frequency 50 Hz / 60 Hz
Power Factor 0.96
Efficiency 87 %
Cooling Specifications
Max. Water Pressure 6 bar
Min. Differential Pressure 3 bar
Min. Water Flow Rate by 4 bar
Power Supply Unit 12 l/min
External Circuit 4.5 l/min
Max. Cooling Water Temperature
35 °C
TruHeat MF Series 3010 – 7040
TruHeat MF Series 3000 TruHeat MF Series 7000
Dimensions (W x H x D)
TruHeat MF Series 3000 483 mm x 400 mm x 754 mm
TruHeat MF Series 5000 555 mm x 505 mm x 843 mm
TruHeat MF Series 7000 600 mm x 1 405 mm x 825 mm
External Circuit 215 mm x 250 mm x 400 mm
Weight
TruHeat MF Series 3000 87 kg
TruHeat MF Series 5000 105 kg
TruHeat MF Series 7000 220 kg
External Circuit 21 kg
Protection Class
TruHeat MF Series 3000 IP 21
TruHeat MF Series 5000 IP 21
TruHeat MF Series 7000 IP 54
External Circuit IP 54
1) At 200 kHz max. 35 kW output power.
Load and Frequency Adaptation in the External Circuit
1) By default, the pre-coil Lpre is available for the frequency range of 20 kHz to 100 kHz.
Lpre1
Lind
Changing the capacitance Ctot or the inductance Ltot
Ltot = Lind + Lpre Ctot = C1 + C2 ... + Cn
Effects due to Changes in the External Circuit
Changed values Effect
Capacitance Ctot
InductanceLtot
Outputfrequency
Outputcurrent
Oscillatorcircuitimpedance
+ = – + –
– = + – +
= + – – +
= – + + –
Interfaces
A / D Interface 37-pin Sub-D
RS 232 / RS 485 9-pin Sub-D
PROFIBUS 9-pin Sub-D
Environmental Specifications
Ambient Temperature +10 °C to +45 °C operation–20 °C to +55 °C storage–20 °C to +70 °C transport
Rel. Air Humidity 10 % – 90 % operation2
30 % – 95 % storage95 % transport
Air Pressure3 800 hPa to 1 013 hPa operation800 hPa to 1 013 hPa storage660 hPa to 1 013 hPa transport
System Components InductorUndervoltage ReleaseSecurity RelayRecooling SystemOptical PyrometerCable Length 5 m to 25 mExternal, Programmable Controller
TruHeat MF Series 3000 / 5000 / 7000
2) No condensation.3) Max. 2 000 above sea level.
TruHeat MF Series 7000
External Circuit 215 mm 410 mm
516 mm
250
mm
105
mm
483 mm 673 mm 483 mm
754 mm
399
mm
554 mm 800 mm 554 mm
843 mm
506
mm
604 mm
769 mm
822 mm
1405
mm
TruHeat MF Series 5000
TruHeat MF Series 3000
© T
RUM
PF H
üttin
ger
Gm
bH +
Co.
KG
, 201
7. A
ll rig
hts
rese
rved
. Sub
ject
to
erro
rs a
nd t
echn
ical
cha
nges
. 147
6527
- V
07
TRUMPF Hüttinger GmbH + Co. KGBötzinger Straße 80 · 79111 Freiburg · Phone +49 761 8971-0Fax +49 761 8971-1150 · E-Mail [email protected] www.trumpf-huettinger.com