tti environmental incorporated 1253 n. church street
TRANSCRIPT
A Service Disabled Veteran Owned Small Business
TTI Environmental Incorporated 1253 N. Church Street Moorestown, New Jersey 08057 Tel: 856-840-8800 Fax: 856-840-8815
Providing Sound Environmental Solutions For Business & Industry
www.ttienv.com
June 27, 2013 Mr. Christopher Eyre TD Bank, N.A. 2059 Springdale Road Cherry Hill, New Jersey 08003 Reference: Phase II Investigation
Alan R. Cantrell Block 538, Lots 13-18 45 Juliustown Road Browns Mills, Pemberton, Burlington County, New Jersey
TTI Project No. 12-1272 TD Project No. 12-006370-03-1 Dear Mr. Eyre: TTI Environmental, Inc. (TTI) is pleased to provide you with this Phase II Investigation for the above referenced facility. For your ease of review, the report is organized in the following manner:
1.0 Background 2.0 Technical Overview
3.0 Site Assessment Summary 4.0 Recommendations & Conclusions
1.0 BACKGROUND
TTI completed a Phase I Environmental Site Assessment (Phase I) of the above referenced property on September 26, 2012. The purpose of the assessment was to identify historical, existing or potential areas of environmental concern. The Phase I was conducted in accordance with the American Society for Testing and Materials Standard Practice for Environmental Site Assessments: Phase I Environmental Site Assessment Process. Figure 1.0 depicts the location of the subject site on a USGS topographic map. The following recognized environmental conditions (RECs) requiring further investigation were identified:
• Abandoned In Place Heating Oil UST • Surficial Staining • Former Dry Cleaning Operation
A summary of the Phase I conclusions regarding these areas of concern is provided below.
TD Bank, N.A. TTI Project No. 12-1272 June 27, 2013 Page 2 of 9
1.0 BACKGROUND (CONTINUED) 1.1 Abandoned In Place Heating Oil UST
According to Alan Cantrell, the property owner, the site formerly utilized a No. 2 heating oil UST of unknown capacity. The UST is currently abandoned in place on the southeast exterior of the subject building. Pemberton Township construction records indicate a tank removal occurred in 2006 by a contactor identified as Mr. John Donelson. No additional information was provided to TTI regarding the abandonment event. USTs represent and area of concern as a failure or leak in the system can impact subsurface soil and water. It is TTI’s opinion that this environmental consideration is a recognized environmental condition (REC). TTI recommended further investigation of this REC.
1.2 Surficial Staining
TTI observed staining on the concrete floor within the subject building in the vicinity of the oil burner and associated return/feed lines. Granular Oil-Dry was used as an absorbent in and around the staining. TTI did not observe any actively leaking petroleum; however, the observed staining was in close proximity to a nearby wall-floor seam. In addition, the amount and duration of the staining is unknown. It is TTI’s opinion that this environmental consideration is a recognized environmental condition (REC). TTI recommended further investigation of this REC.
1.3 Former Dry Cleaning Operation
Mr. Cantrell indicated that the portion of the subject building occupied by the tobacco shop formerly operated as an offsite dry cleaning operation. As part of this assessment, TTI submitted a request to review records from the Pemberton Township Tax Assessor’s Office and Construction Departments. TTI received information from the Assessor’s office include the site’s property record card, ownership information, historic use, etc. According to the records provided, the former dry cleaning operation was located on site in 1973. Dry cleaners represent an environmental concern as the release of hazardous dry cleaning materials could cause soil and/or groundwater contamination. At this time, TTI cannot confirm that the operation did not engage in onsite dry-cleaning operations. In addition, TTI suspects the dry cleaner could have operated on site. It is TTI’s opinion that this environmental consideration is a recognized environmental condition (REC). TTI recommended further investigation of this REC.
TD Bank, N.A. TTI Project No. 12-1272 June 27, 2013 Page 3 of 9
2.0 TECHNICAL OVERVIEW TTI personnel involved in the collection of samples were Ms. Kristin Kaeser, TTI Environmental
Project Supervisor (NJDEP Certification No. 236270) and Mr. Max Demianovich, TTI Environmental Assistant Project Manager.
2.1 Ground Penetrating Radar (GPR) Survey
Prior to field sampling activities, TTI conducted oversight of a GPR survey of the subject site in the vicinity of the abandoned in place UST. The survey was conducted to evaluate the potential presence and/or evidence of historic underground storage tanks at the property. The survey results were also utilized to guide the sample location points. The GPR survey was performed by Enviroprobe Service, Inc. of Moorestown, NJ (Enviroprobe). To complete this investigation, Enviroprobe utilized a Radiodetection RD1000 cart-mounted Ground Penetrating Radar (GPR) unit with a 250 MHz antenna, a Radiodetection 8000T10 multi-frequency transmitter, a Radiodetection 8000 receiver, and a Fisher TW-6 metallic locator. Areas of interest were marked out using spray paint. Upon completion of this survey, one (1) anomaly was identified in the area of the suspected UST. The anomaly was approximately five (5) feet by eight (8) and located approximately three (3) feet below grade. The size and location of this anomaly appeared consistent with an abandoned in place UST between 1,000 gallons and 1,500 gallons in capacity. A copy of the geophysical investigation report prepared by Enviroprobe pertaining to the subject site GPR survey is included herein as Appendix A.
2.2 Soil Sampling Methodology
The soil borings for this Phase II Investigation were installed using a direct push hydraulic sampling unit. Soil samples were collected using dedicated plastic sleeves in the unit’s macro core sampling device. A concrete core drill was utilized to facilitate interior sampling as necessary. Soil cores were continuously field screened using a Photoionization detector (PID) for organic vapor concentrations. Soil selected for chemical analysis from each core was transferred from the sampling device into laboratory supplied sample containers. Samples were shipped to the designated laboratory in ice packed coolers under chain-of-custody documentation.
TD Bank, N.A. TTI Project No. 12-1272 June 27, 2013 Page 4 of 9
2.0 TECHNICAL OVERVIEW (CONTINUED)
2.3 Groundwater Sampling Methodology
Groundwater sampling activities were conducted in general conformance with N.J.A.C. 7:26E – Technical Requirements for Site Remediation and the NJDEP Field Sampling Procedures Manual, August 2005. Two (2) temporary well points were placed using a GeoProbe direct push hydraulic unit in order to assess groundwater quality in the historic dry cleaner area. The well point consisted of a 1.5 inch diameter PVC casing and screen. The well point was removed from the ground within 48 hours of installation and the probe holes filled with native soil, sand, and bentonite. Both well points were advanced to a total depth of approximately 12 feet below grade and completed using 10 feet of PVC screen. Groundwater samples were collected using disposable, single use bailers. Each bailer was allowed to travel to the bottom of the temporary well point prior to sample collection. The groundwater samples were transferred directly into laboratory supplied sample containers and transported to the laboratory in ice packed coolers under Chain of Custody documentation.
2.4 Analytical Methodology
Samples collected for analysis were submitted to Alpha Analytical of Westborough, Massachusetts (NJDEP Certification No. MA935). The following methodologies were used: Soil
• EPH Category 1 • Volatile Organic Compounds via EPA Method 5035
Groundwater
• Volatile Organic Compounds via EPA Method 8260B
2.5 Non-Conformance Issues
Volatile Organics
The WG609456-3 Method Blank, associated with L1308954-01 and -02, has a TIC concentration above the reporting limit. The results of the original analysis are reported and are qualified with a "B" for any associated sample concentrations that are less than 5x the blank concentration for this TIC. NJ Extractable Petroleum Hydrocarbons (Total)
The WG609036-5 Laboratory Duplicate RPD (56%), performed on L1308954-05, is outside the acceptance criteria. The elevated RPD has been attributed to the non-homogeneous nature of the sample utilized for the laboratory duplicate. None of these nonconformance issues have impacted the quality of the data. The final laboratory report (L1308954) is attached is attached as Appendix B.
TD Bank, N.A. TTI Project No. 12-1272 June 27, 2013 Page 5 of 9
3.0 SITE ASSESSMENT SUMMARY
Limitations: TTI’s investigation was limited due to the presence of subgrade utilities in the vicinity of exterior sample locations. Additionally, the UST being investigated was abandoned in place; as such, sampling directly below the tank centerline was not feasible. Finally, the location of the surficial staining sample location was limited due to the presence of stockpiled material and interior shelving units. The location of all sample points and anomalies identified during the GPR survey are depicted on Figure 2.0. 3.1 Abandoned In Place Heating Oil UST
TTI performed an investigation of the abandoned in place heating oil UST using the NJDEP’s Technical Guidance for the Investigation of Underground Storage Tank Systems v1.0 dated April 12, 2012 for guidance. Based on the suspected capacity of the UST (between 1,000 and 1,500 gallons) one (1) sample was collected from each side of the tank for a total of four (4) soil samples. The sample depths were selected at the suspected invert of the tank and/or based on positive bias (olfactory/visual observation and PID screening). A total of two (2) of these samples were submitted for EPH Category 1 analysis. The selection of samples UST-3 and UST-4 for analysis was based on a petroleum odor detected during borehole advancement. Each sample was collected from the half foot interval directly above the observed soil-groundwater interface. A summary of the results is provided below in Table 1.0.
Table 1.0: UST Investigation Soil Analytical Data (mg/kg) Sample
Location Depth (ft) Date PID EPH
Result NJDEP Further Action
Criteria
UST-3 8-8.5 05/16/2013 ND 375 1,000 mg/kg – Further
Action Criteria
5,100 mg/kg = Remedial Criteria UST-4 7.5-8 05/16/2013 ND ND
ppm = parts per million; ND = None detected; EPH (Extractable Petroleum Hydrocarbon Category 1); PID = photoionization detector A review of the data indicates that no EPH category 1 results were detected above the NJDEP further action criteria of 1,000 mg/kg. As such, no samples were selected for contingent analysis.
3.2 Surficial Staining
TTI performed a subsurface investigation in the vicinity of surficial staining observed near the site’s current oil fired boiler. Subsurface soils were sampled after exposure via concrete core drilling. The sample was collected from the half foot interval directly below the building’s concrete slab floor and submitted for EPH Category 1 analysis. A summary of the results is provided in Table 2.0 on the following page.
TD Bank, N.A. TTI Project No. 12-1272 June 27, 2013 Page 6 of 9
3.0 SITE ASSESSMENT SUMMARY (CONTINUED)
3.2 Surficial Staining – Continued
Table 2.0: Surficial Staining Investigation Soil Analytical Data (mg/kg) Sample
Location Depth (ft) Date PID EPH
Result NJDEP Further Action
Criteria
I-1 0.5-1.0 05/16/2013 ND 40.8
1000 mg/kg – Further Action Criteria
5100 mg/kg = Remedial
Criteria mg/kg = milligrams per kilogram; ND = None detected; PID = photoionization detector; EPH (Extractable Petroleum Hydrocarbon Category 1); A review of the data indicates that no EPH category 1 results were detected above the NJDEP further action criteria of 1,000 mg/kg. As such, no samples were selected for contingent analysis.
3.3 Former Dry Cleaning Operation
TTI installed two (2) borings to investigate this REC. A soil sample was collected from each borehole at the half foot interval directly above the observed soil/water interface. The samples were submitted for Volatile Organic Compound (VOC) analysis. The borings were advanced to a total depth of 12 feet below grade. Groundwater was encountered at approximately 7.5 to eight (8) feet below grade. A summary of the soil results is provided below in Table 3.0.
Table 3.0: Former Dry Cleaning Operation Soil Analytical Data (mg/kg)
Sample Location Depth (ft) Date PID
Targeted VOC Result
VOC Tentatively Identified Compound
Result
DC-1 7.0-7.5 05/16/2013 ND ND 0.0457
DC-2 7.5-8.0 05/16/2013 ND ND 0.1274
mg/kg = milligrams per kilogram; ND = None detected; PID = photoionization detector; VOC = (Volatile Organic Compound
A review of the data indicates that no targeted VOCs were detected. Additionally, tentatively identified compounds (TICs) for each sample were detected at a concentration of less than one (1) mg/kg.
TD Bank, N.A. TTI Project No. 12-1272 June 27, 2013 Page 7 of 9
3.0 SITE ASSESSMENT SUMMARY (CONTINUED)
3.3 Former Dry Cleaning Operation – Continued
At the conclusion of soil sampling, each bore hole was converted to a temporary well point to facilitate ground water sampling (DC-1 was converted to TWP-1 and DC-2 was converted to TWP-2). Each well point was purged to clear via a peristaltic pump prior to sampling. The samples were submitted for Volatile Organic Compound (VOC) analysis. A summary of the groundwater results is provided below in Table 4.0.
Table 4.0: Former Dry Cleaning Operation Groundwater Analytical Data (ug/L)
Sample Location Date
Targeted VOC Result
VOC Tentatively Identified Compound
Result
TWP-1 05/16/2013 ND ND
TWP-2 05/16/2013 ND 52
ug/L = micro grams per liter; ND = None detected; VOC (Volatile Organic Compound
A review of the data indicates that no targeted VOCs were detected. Additionally, tentatively identified compounds for TWP-2 were detected at a concentration of 52 ug/L. This value is below the groundwater remedial standard for total tentatively identified compounds of 500 ug/L.
TD Bank, N.A. TTI Project No. 12-1272 June 27, 2013 Page 8 of 9
4.0 CONCLUSIONS AND RECOMMENDATIONS
TTI’s Phase II investigation evaluated the potential environmental impact from an abandoned in place heating oil UST, surficial staining, and a former dry cleaning operation. The investigation was conducted in general conformance with NJDEP requirements. With regard to this Phase II, TTI concludes the following: Abandoned In Place Heating Oil UST: UST-3 produced an EPH result of 375 mg/kg at 8.0 – 8.5 feet below grade. Based on the fact that the EPH Category 1 result was not above the NJDEP further action criteria of 1,000 mg/kg and no signs of impact to groundwater were observed, i.e. sheen/product in groundwater, groundwater odor, etc., TTI is recommending no further action or investigation with regard to this recognized environmental condition. Surficial Staining: Soil sampling in the vicinity of observed interior surficial staining produced an EPH Category 1 result of 40.8 mg/kg. This result is below the NJDEP EPH Category 1 further action criteria of 1,000 mg/kg. As such, TTI is recommending no further action or investigation with regard to this recognized environmental condition. Former Dry Cleaning Operation: TTI’s soil/groundwater investigation identified no targeted or tentatively identified VOCs above applicable NJDEP standards. As such, TTI is recommending no further action or investigation with regard to this recognized environmental condition.
TD Bank, N.A. TTI Project No. 12-1272 June 27, 2013 Page 9 of 9
4.0 CONCLUSIONS AND RECOMMENDATIONS Thank you for allowing TTI to provide you with professional environmental consulting services. If you should have any questions or require additional information, please feel free to contact us at any time.
Sincerely,
TTI ENVIRONMENTAL, INC.
Max Demianovich
Assistant Project Manager
Kristin M. Kaeser
Environmental Project Supervisor
Figure 1.0: Site Location Diagram Figure 2.0: Sample Location Diagram Appendix A: Geophysical Investigation Report Appendix A: Alpha Analytical Laboratory Report L1308954 \\TTISERVER00\Public\TTI\TD Bank, NA\2012 Projects\12-1272 P2 Browns Mill\12-1272.P2.Letter Report.docx
FIGURE 1.0
REGIONAL SITE LOCATION MAP BROWNS MILLS QUAD, 1997
45 Juliustown Road Block 538, Lots 13-18 Browns Mills (Pemberton), Burlington County, NJ
SCALE As Shown
DRAWN BY USGS
DATE 06/2013
PROJECT 12-1272
APP’D BY MD
DRAWING NO. 1.0
TTI Environmental, Inc. www.ttienv.com
FIGURE 2.0:
SAMPLE LOCATION DIAGRAM
45 Juliustown Road Block 538, Lots 13-18 Browns Mills (Pemberton), Burlington County, NJ
SCALE As Shown
DRAWN BY USGS
DATE 06/2013
PROJECT 12-1272
APP’D BY MD
DRAWING NO. 1.0
TTI Environmental, Inc. www.ttienv.com
Appendix A: Geophysical Investigation Report
GEOPHYSICAL INVESTIGATION REPORT
PERFORMED AT:
45 Juliustown Rd.Browns Mills, NJ 08015
PREPARED FOR:
Max Demianovich TTI Environmental, Inc.1253 North Church Rd.Moorestown, NJ 08057
PREPARED BY:
Ken LindesGeophysical Technician
Enviroprobe Service, Inc.908 N. Lenola Road
Moorestown, NJ 08057(856) 858-8584(800) 596-7472
May 25, 2013
Enviroprobe Service, Inc. 2
1.0 INTRODUCTION
Enviroprobe Service, Inc. (Enviroprobe) is an environmental investigation services firm which provides monitoring well installation (HSA), Geoprobe (DPT) drilling services and Environmental & Engineering Geophysics (EEG) services to the environmental consulting and engineering community.
Enviroprobe conducted a subsurface geophysical investigation at the subject property within client-specified areas of concern. Due to conditions and objectives, the investigation utilized a Radiodetection RD1000 cart-mounted Ground Penetrating Radar (GPR) unit with a 250 MHz antenna, a Radiodetection 8000T10 multi-frequency transmitter, a Radiodetection 8000 receiver, and a Fisher TW-6 metallic locator.
Ground penetrating radar (commonly called GPR) is a geophysical method that has been developed over the past thirty years for shallow, high-resolution, subsurface investigations of the earth. GPR uses high frequency pulsed electromagnetic waves (generally 10 MHz to 2,000 MHz) to acquire subsurface information. An EM wave is propagated downward into the ground by a transmitting antenna. Where abrupt changes in electrical properties occur in the subsurface, a portion of the energy is reflected back to the surface. This reflected wave is detected by a receiver antenna and transmitted to a control unit for real time processing and display. The penetration depth of the RD1000 unit varies from several inches to tens of feet according to site-specific conditions. The penetration depth decreases with increased soil conductivity. The penetration depth is the greatest in ice, dry sands, and fine gravels. Clayey, highly saline or saturated soils, areas covered by concrete, foundry slag, or other highly conductive materials greatly reduce GPR penetration. GPR is a method that is commonly used for environmental, engineering, archaeological, and other shallow investigations.
The Radiodetection (RD) transmitter and receiver are commonly used for pipe and cable locating. The multi-frequency transmitter can be directly connected, clamped, or used to induce a signal in a target line while the multi-frequency receiver is used to measure the signal from energized lines.
The Fisher TW-6 metallic locator is designed to find pipes, cables and other metallic objects such as underground storage tanks (USTs). The TW-6 transmitter generates an electromagnetic field that induces electrical currents in the subsurface. These currents produce a secondary electromagnetic field that is measured by the TW-6 receiver. One surveyor can carry both the transmitter and receiver together to search for underground metallic objects, although the TW-6 response can also be affected by the electrical properties of non-metallic materials in the subsurface.
2.0 SCOPE OF WORK
On May 16, 2013, a geophysical technician from Enviroprobe Service Inc. was mobilized to the subject property to perform a geophysical investigation. The purpose of
Enviroprobe Service, Inc. 3
this investigation was to detect possible USTs, designate underground conduits/utilities, and investigate proposed boring locations within all accessible exterior portions of the subject property. The ground surface of the survey area consisted of paved, concrete, landscaped, and natural soil surfaces.
3.0 SURVEY RESULTS
The survey was conducted using a cart-mounted GPR unit, a Fisher TW-6 metallic locator, and a RD unit. The RD unit was used to trace common utilities from sources in and around the survey area. The RD receiver was also used in the passive mode to search for live underground electrical power cables and other utilities emitting 60Hz electromagnetic signals. When possible, the locations of utilities were confirmed with the GPR. Whenever possible and necessary, the manhole covers in and around the survey area were opened and the manholes were visually inspected for underground utilities. A GPR survey was also performed in a grid pattern in at least two orthogonal directions to search for underground utilities. Designated utilities were marked on-site with spray paint using the following colors; blue – water and white – vent line.
The GPR and TW-6 were used in a grid pattern over all client-specified areas of the property. Based on the results of the GPR and TW-6 surveys, a metallic anomaly consistent with an UST was identified adjacent the eastern side of the main building. This rectangular anomaly measured approximately 5 ft by 8 ft and was located at a depth of approximately 3 ft. The approximate extent of this anomaly was designated on-site with white spray paint.
Proposed boring locations were investigated with the GPR, TW-6, and RD receiver. When possible, an area of approximately 10 ft by 10 ft surrounding each boring location was scanned. In some cases, obstructions prevented an investigation of the entire 10 ft by 10 ft area. All designated anomalies were marked on-site with spray paint.
4.0 LIMITATIONS
The client-selected areas of the property had obstructions including debris, landscaping, and walls. These objects prevented a thorough investigation of the spaces beneath and immediately adjacent to them.
Due to surface conditions and subsurface content, the GPR signal penetration was estimated at 4.0 feet in the majority of the survey area. This penetration was reduced in areas of concrete cover.
The TW-6 survey was kept up to 6 feet away from above ground objects containing metals depending on the sizes, shapes and positions of the metal objects. The TW-6 survey was not effective in areas with reinforced concrete.
Enviroprobe Service, Inc. 4
Due to the dielectric properties of the subsurface, plastic polymer and fiberglass utilities may not have been detected.
All field services were conducted in compliance with the industry standard of care guidelines found in ASCE 38-02 (Level B).
5.0 WARRANTIES
The field observations and measurements reported herein are considered sufficient in detail and scope for this project. Enviroprobe Service, Inc. warrants that the findings and conclusions contained herein have been promulgated in accordance with generally accepted environmental engineering methods. There is a possibility that conditions may exist which could not be identified within the scope of this project and were not apparent during the site activities performed for this project.
Enviroprobe represents that the services were performed in a manner consistent with that level of care and skill ordinarily exercised by environmental consultants under similar circumstances. No other representations to Client, express or implied, and no warranty or guarantee is included or intended in this agreement, or in any report, document, or otherwise.
Enviroprobe Service, Inc. believes that the information provided in this report is reliable. However, Enviroprobe cannot warrant or guarantee that the information provided by others is complete or accurate. No other warranties or guarantees are implied or expressed.
GPR data is subject to signal anomalies and operator interpretation. The GPR data is intended to provide the locations of areas of concern requiring additional investigation or the approximate location of underground structures and utilities. Great care must be utilized when excavating and/or drilling around underground structures and utilities since GPR data can only be used for estimation purposes and GPR data is subject to misinterpretation. Enviroprobe can not guarantee that utilities, post-tension cables, and/or rebar will not be incurred during drilling, cutting, coring, or excavating activities.
This report was prepared pursuant to the contract Enviroprobe has with the Client. That contractual relationship included an exchange of information about the property that was unique and between Enviroprobe and its client and serves as the basis upon which this report was prepared. Because of the importance of the communication between Enviroprobe and its client, reliance or any use of this report by anyone other than the Client, for whom it was prepared, is prohibited and therefore not foreseeable to Enviroprobe.
Reliance or use by any such third party without explicit authorization in the report does not make said third party a third party beneficiary to Enviroprobe contract with the Client. Any such unauthorized reliance on or use of this report, including any of its
Enviroprobe Service, Inc. 5
information or conclusions, will be at the third party's risk. For the same reasons, no warranties or representations, expressed or implied in this report, are made to any such third party.
Appendix B: Alpha Analytical Laboratory Report L1308954
L1308954
TTI Environmental, Inc.
12-1272
Not Specified
Client:
Project Name:
Project Number:
05/28/13
Eight Walkup Drive, Westborough, MA 01581-1019
Lab Number:
Report Date:
508-898-9220 (Fax) 508-898-9193 800-624-9220 - www.alphalab.com
1253 North Church Street
Moorestown, NJ 08057
Max DemianovichATTN:
ANALYTICAL REPORT
Certifications & Approvals: MA (M-MA086), NY (11148), CT (PH-0574), NH (2003), NJ NELAP (MA935), RI (LAO00065), ME (MA00086),PA (68-03671), USDA (Permit #P-330-11-00240), NC (666), TX (T104704476), DOD (L2217), US Army Corps of Engineers.
(856) 840-8800Phone:
The original project report/data package is held by Alpha Analytical. This report/data package is paginated and should be reproduced only in itsentirety. Alpha Analytical holds no responsibility for results and/or data that are not consistent with the original.
Serial_No:05281316:15
Page 1 of 75
L1308954-01
L1308954-02
L1308954-03
L1308954-04
L1308954-05
L1308954-06
L1308954-07
L1308954-08
L1308954-09
L1308954-10
L1308954-11
Alpha Sample ID
DC-1
DC-2
UST-1
UST-2
UST-3 8-8.5
UST-4 7.5-8
I-1
TWP-1
TWP-2
UST-3 6.5-7
UST-4 6.5-7
Client ID
PEMBERTON, NJ
PEMBERTON, NJ
PEMBERTON, NJ
PEMBERTON, NJ
PEMBERTON, NJ
PEMBERTON, NJ
PEMBERTON, NJ
PEMBERTON, NJ
PEMBERTON, NJ
PEMBERTON, NJ
PEMBERTON, NJ
Sample Location
Not Specified
12-1272
Project Name:Project Number:
Lab Number: Report Date:
L130895405/28/13
05/16/13 10:15
05/16/13 10:40
05/16/13 10:54
05/16/13 11:02
05/16/13 11:22
05/16/13 11:31
05/16/13 10:42
05/16/13 11:50
05/16/13 12:13
05/16/13 11:18
05/16/13 11:32
Collection Date/Time
Serial_No:05281316:15
Page 2 of 75
Not Specified
12-1272
Project Name:
Project Number:
Lab Number:
Report Date:L1308954
05/28/13
Case Narrative
The samples were received in accordance with the Chain of Custody and no significant deviations were encountered during the preparation
or analysis unless otherwise noted. Sample Receipt, Container Information, and the Chain of Custody are located at the back of the report.
Results contained within this report relate only to the samples submitted under this Alpha Lab Number and meet all of the requirements of
NELAC, for all NELAC accredited parameters. The data presented in this report is organized by parameter (i.e. VOC, SVOC, etc.). Sample
specific Quality Control data (i.e. Surrogate Spike Recovery) is reported at the end of the target analyte list for each individual sample,
followed by the Laboratory Batch Quality Control at the end of each parameter. If a sample was re-analyzed or re-extracted due to a
required quality control corrective action and if both sets of data are reported, the Laboratory ID of the re-analysis or re-extraction is
designated with an "R" or "RE", respectively. When multiple Batch Quality Control elements are reported (e.g. more than one LCS), the
associated samples for each element are noted in the grey shaded header line of each data table. Any Laboratory Batch, Sample Specific %
recovery or RPD value that is outside the listed Acceptance Criteria is bolded in the report. Performance criteria for CAM and RCP methods
allow for some LCS compound failures to occur and still be within method compliance. In these instances, the specific failures are not
narrated but are noted in the associated QC table. This information is also incorporated in the Data Usability format for our Data Merger tool
where it can be reviewed along with any associated usability implications. Soil/sediments, solids and tissues are reported on a dry weight
basis unless otherwise noted. Definitions of all data qualifiers and acronyms used in this report are provided in the Glossary located at the
back of the report.
In reference to questions H (CAM) or 4 (RCP) when "NO" is checked, the performance criteria for CAM and RCP methods allow for some
quality control failures to occur and still be within method compliance. In these instances the specific failure is not narrated but noted in the
associated QC table. The information is also incorporated in the Data Usability format of our Data Merger tool where it can be reviewed
along with any associated usability implications.
Please see the associated ADEx data file for a comparison of laboratory reporting limits that were achieved with the regulatory Numerical
Standards requested on the Chain of Custody.
HOLD POLICY
For samples submitted on hold, Alpha's policy is to hold samples free of charge for 30 days from the date the project is completed. After 30
days, we will dispose of all samples submitted including those put on hold unless you have contacted your Client Service Representative and
made arrangements for Alpha to continue to hold the samples.
Please contact Client Services at 800-624-9220 with any questions.
Serial_No:05281316:15
Page 3 of 75
Case Narrative (continued)
Not Specified
12-1272
Project Name:
Project Number:
Lab Number:
Report Date:L1308954
05/28/13
Report Submission
This final report replaces the partial report issued earlier today, and includes the results of all requested
analyses.
All non-detect (ND) or estimated concentrations (J-qualified) have been quantitated to the limit noted in the
MDL column.
Volatile Organics
The WG609456-3 Method Blank, associated with L1308954-01 and -02, has a TIC concentration above the
reporting limit. The results of the original analysis are reported and are qualified with a "B" for any associated
sample concentrations that are less than 5x the blank concentration for this TIC.
NJ Extractable Petroleum Hydrocarbons (Total)
The WG609036-5 Laboratory Duplicate RPD (56%), performed on L1308954-05, is outside the acceptance
criteria. The elevated RPD has been attributed to the non-homogeneous nature of the sample utilized for the
laboratory duplicate.
I, the undersigned, attest under the pains and penalties of perjury that, to the best of my knowledge and belief and based upon my personal inquiry of those responsible for providing the information contained in this analytical report, such information is accurate and complete. This certificate of analysis is not complete unless this page accompanies any and all pages of this report.
Authorized Signature:
Title: Technical Director/Representative Date: 05/28/13
Serial_No:05281316:15
Page 4 of 75
ORGANICS
Serial_No:05281316:15
Page 5 of 75
VOLATILES
Serial_No:05281316:15
Page 6 of 75
FF
1,2-Dibromo-3-chloropropane
1,4-Dioxane
1,2-Dibromoethane
Methylene chloride
1,1-Dichloroethane
Chloroform
Carbon tetrachloride
1,2-Dichloropropane
Dibromochloromethane
1,1,2-Trichloroethane
Tetrachloroethene
Chlorobenzene
Trichlorofluoromethane
1,2-Dichloroethane
1,1,1-Trichloroethane
Bromodichloromethane
trans-1,3-Dichloropropene
cis-1,3-Dichloropropene
Bromoform
1,1,2,2-Tetrachloroethane
Benzene
Toluene
Ethylbenzene
Chloromethane
Bromomethane
Vinyl chloride
Chloroethane
1,1-Dichloroethene
trans-1,2-Dichloroethene
Trichloroethene
1,2-Dichlorobenzene
Parameter Result Dilution Factor
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Qualifier Units RL
Volatile Organics by GC/MS-5035 - Westborough Lab
SAMPLE RESULTS
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
0.0063
0.13
0.0050
0.0063
0.0019
0.0019
0.0013
0.0044
0.0013
0.0019
0.0013
0.0013
0.0063
0.0013
0.0013
0.0013
0.0013
0.0013
0.0050
0.0013
0.0013
0.0019
0.0013
0.0063
0.0025
0.0025
0.0025
0.0013
0.0019
0.0013
0.0063
05/28/13
DC-1Client ID:05/16/13 10:15Date Collected:05/17/13Date Received:
PEMBERTON, NJSample Location:
L1308954-01Lab ID:
Field Prep: Not SpecifiedMatrix: SoilAnalytical Method:Analytical Date:Analyst:
1,8260C05/20/13 15:47BN 88%Percent Solids:
MDL
0.0010
0.022
0.00022
0.0025
0.00022
0.00047
0.00026
0.00029
0.00039
0.00038
0.00018
0.00044
0.00015
0.00018
0.00014
0.00029
0.00015
0.00016
0.00052
0.00022
0.00015
0.00014
0.00018
0.00099
0.00043
0.00018
0.00040
0.00026
0.00027
0.00019
0.00023
Serial_No:05281316:15
Page 7 of 75
1,3-Dichlorobenzene
1,4-Dichlorobenzene
Methyl tert butyl ether
p/m-Xylene
o-Xylene
cis-1,2-Dichloroethene
Styrene
Dichlorodifluoromethane
Acetone
Carbon disulfide
2-Butanone
4-Methyl-2-pentanone
2-Hexanone
Bromochloromethane
Isopropylbenzene
1,2,3-Trichlorobenzene
1,2,4-Trichlorobenzene
Methyl Acetate
Cyclohexane
Methyl cyclohexane
1,1,2-Trichloro-1,2,2-Trifluoroethane
Parameter Result Dilution Factor
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Qualifier Units RL
Volatile Organics by GC/MS-5035 - Westborough Lab
SAMPLE RESULTS
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
0.0063
0.0063
0.0025
0.0025
0.0025
0.0013
0.0025
0.013
0.045
0.013
0.013
0.013
0.013
0.0063
0.0013
0.0063
0.0063
0.0050
0.025
0.0050
0.025
05/28/13
DC-1Client ID:05/16/13 10:15Date Collected:05/17/13Date Received:
PEMBERTON, NJSample Location:
L1308954-01Lab ID:
Field Prep: Not Specified
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
J
J
J
J
J
J
J
J
J
J
0.0068
0.0050
0.0072
0.0037
0.0078
0.0036
0.0030
0.0027
0.0031
0.0028
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
1
1
1
1
1
1
1
1
1
1
Tentatively Identified Compounds
MDL
0.00023
0.00030
0.00013
0.00041
0.00034
0.00019
0.00039
0.00028
0.0039
0.0025
0.00045
0.00031
0.00024
0.00025
0.00021
0.00021
0.0010
0.00096
0.0014
0.0016
0.00034
Serial_No:05281316:15
Page 8 of 75
Parameter Result Dilution FactorQualifier Units RL
Volatile Organics by GC/MS-5035 - Westborough Lab
SAMPLE RESULTS
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
1,2-Dichloroethane-d4
Toluene-d8
4-Bromofluorobenzene
Dibromofluoromethane
124
94
116
107
70-130
70-130
70-130
70-130
Acceptance CriteriaSurrogate % Recovery Qualifier
05/28/13
DC-1Client ID:05/16/13 10:15Date Collected:05/17/13Date Received:
PEMBERTON, NJSample Location:
L1308954-01Lab ID:
Field Prep: Not Specified
MDL
Serial_No:05281316:15
Page 9 of 75
1,2-Dibromo-3-chloropropane
1,4-Dioxane
1,2-Dibromoethane
Methylene chloride
1,1-Dichloroethane
Chloroform
Carbon tetrachloride
1,2-Dichloropropane
Dibromochloromethane
1,1,2-Trichloroethane
Tetrachloroethene
Chlorobenzene
Trichlorofluoromethane
1,2-Dichloroethane
1,1,1-Trichloroethane
Bromodichloromethane
trans-1,3-Dichloropropene
cis-1,3-Dichloropropene
Bromoform
1,1,2,2-Tetrachloroethane
Benzene
Toluene
Ethylbenzene
Chloromethane
Bromomethane
Vinyl chloride
Chloroethane
1,1-Dichloroethene
trans-1,2-Dichloroethene
Trichloroethene
1,2-Dichlorobenzene
Parameter Result
J
Dilution Factor
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
0.00024
ND
ND
ND
ND
ND
ND
ND
ND
ND
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Qualifier Units RL
Volatile Organics by GC/MS-5035 - Westborough Lab
SAMPLE RESULTS
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
0.0055
0.11
0.0044
0.0055
0.0016
0.0016
0.0011
0.0038
0.0011
0.0016
0.0011
0.0011
0.0055
0.0011
0.0011
0.0011
0.0011
0.0011
0.0044
0.0011
0.0011
0.0016
0.0011
0.0055
0.0022
0.0022
0.0022
0.0011
0.0016
0.0011
0.0055
05/28/13
DC-2Client ID:05/16/13 10:40Date Collected:05/17/13Date Received:
PEMBERTON, NJSample Location:
L1308954-02Lab ID:
Field Prep: Not SpecifiedMatrix: SoilAnalytical Method:Analytical Date:Analyst:
1,8260C05/20/13 16:15BN 80%Percent Solids:
MDL
0.00087
0.019
0.00020
0.0022
0.00020
0.00041
0.00023
0.00025
0.00034
0.00033
0.00015
0.00038
0.00013
0.00016
0.00012
0.00025
0.00013
0.00014
0.00046
0.00019
0.00013
0.00012
0.00016
0.00086
0.00037
0.00016
0.00035
0.00023
0.00023
0.00017
0.00020
Serial_No:05281316:15
Page 10 of 75
1,3-Dichlorobenzene
1,4-Dichlorobenzene
Methyl tert butyl ether
p/m-Xylene
o-Xylene
cis-1,2-Dichloroethene
Styrene
Dichlorodifluoromethane
Acetone
Carbon disulfide
2-Butanone
4-Methyl-2-pentanone
2-Hexanone
Bromochloromethane
Isopropylbenzene
1,2,3-Trichlorobenzene
1,2,4-Trichlorobenzene
Methyl Acetate
Cyclohexane
Methyl cyclohexane
1,1,2-Trichloro-1,2,2-Trifluoroethane
Parameter Result Dilution Factor
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Qualifier Units RL
Volatile Organics by GC/MS-5035 - Westborough Lab
SAMPLE RESULTS
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
0.0055
0.0055
0.0022
0.0022
0.0022
0.0011
0.0022
0.011
0.040
0.011
0.011
0.011
0.011
0.0055
0.0011
0.0055
0.0055
0.0044
0.022
0.0044
0.022
05/28/13
DC-2Client ID:05/16/13 10:40Date Collected:05/17/13Date Received:
PEMBERTON, NJSample Location:
L1308954-02Lab ID:
Field Prep: Not Specified
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
J
J
J
J
J
J
J
J
J
J
J
0.0046
0.0093
0.0054
0.015
0.013
0.014
0.015
0.012
0.018
0.0064
0.0028
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
1
1
1
1
1
1
1
1
1
1
1
Tentatively Identified Compounds
MDL
0.00020
0.00027
0.00011
0.00036
0.00030
0.00016
0.00034
0.00024
0.0034
0.0022
0.00039
0.00027
0.00021
0.00022
0.00018
0.00018
0.00087
0.00084
0.0012
0.0014
0.00030
Serial_No:05281316:15
Page 11 of 75
Parameter Result Dilution FactorQualifier Units RL
Volatile Organics by GC/MS-5035 - Westborough Lab
SAMPLE RESULTS
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
1,2-Dichloroethane-d4
Toluene-d8
4-Bromofluorobenzene
Dibromofluoromethane
124
105
107
107
70-130
70-130
70-130
70-130
Acceptance CriteriaSurrogate % Recovery Qualifier
05/28/13
DC-2Client ID:05/16/13 10:40Date Collected:05/17/13Date Received:
PEMBERTON, NJSample Location:
L1308954-02Lab ID:
Field Prep: Not Specified
Unknown
Unknown
Unknown
J
J
J
0.0036
0.0051
0.0032
mg/kg
mg/kg
mg/kg
1
1
1
Tentatively Identified Compounds
MDL
Serial_No:05281316:15
Page 12 of 75
1,2-Dibromoethane
1,2-Dibromo-3-chloropropane
Parameter Result Dilution Factor
ND
ND
ug/l
ug/l
1
1
Qualifier Units RL
Microextractables by GC - Westborough Lab
SAMPLE RESULTS
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
0.011
0.011
05/28/13
TWP-1Client ID:05/16/13 11:50Date Collected:05/17/13Date Received:
PEMBERTON, NJSample Location:
L1308954-08Lab ID:
Field Prep: Not SpecifiedMatrix: WaterAnalytical Method:Analytical Date:Analyst:
1,801105/25/13 00:12SR
Extraction Date: 05/24/13 13:00
MDL
0.003
0.004
Serial_No:05281316:15
Page 13 of 75
Methylene chloride
1,1-Dichloroethane
Chloroform
Carbon tetrachloride
1,2-Dichloropropane
Dibromochloromethane
1,1,2-Trichloroethane
Tetrachloroethene
Chlorobenzene
Trichlorofluoromethane
1,2-Dichloroethane
1,1,1-Trichloroethane
Bromodichloromethane
trans-1,3-Dichloropropene
cis-1,3-Dichloropropene
Bromoform
1,1,2,2-Tetrachloroethane
Benzene
Toluene
Ethylbenzene
Chloromethane
Bromomethane
Vinyl chloride
Chloroethane
1,1-Dichloroethene
trans-1,2-Dichloroethene
Trichloroethene
1,2-Dichlorobenzene
1,3-Dichlorobenzene
1,4-Dichlorobenzene
Methyl tert butyl ether
Parameter Result Dilution Factor
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Qualifier Units RL
Volatile Organics by GC/MS - Westborough Lab
SAMPLE RESULTS
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
2.5
2.5
2.5
0.50
1.0
0.50
1.5
0.50
2.5
2.5
0.50
2.5
0.50
0.50
0.50
2.0
0.50
0.50
2.5
2.5
2.5
2.5
1.0
2.5
0.50
2.5
0.50
2.5
2.5
2.5
2.5
05/28/13
TWP-1Client ID:05/16/13 11:50Date Collected:05/17/13Date Received:
PEMBERTON, NJSample Location:
L1308954-08Lab ID:
Field Prep: Not SpecifiedMatrix: WaterAnalytical Method:Analytical Date:Analyst:
1,8260C05/23/13 00:21PD
MDL
0.70
0.70
0.70
0.16
0.30
0.19
0.50
0.18
0.70
0.70
0.16
0.70
0.19
0.16
0.14
0.65
0.19
0.19
0.70
0.70
0.70
0.70
0.33
0.70
0.18
0.70
0.17
0.70
0.70
0.70
0.70
Serial_No:05281316:15
Page 14 of 75
p/m-Xylene
o-Xylene
cis-1,2-Dichloroethene
Styrene
Dichlorodifluoromethane
Acetone
Carbon disulfide
2-Butanone
4-Methyl-2-pentanone
2-Hexanone
Bromochloromethane
1,2-Dibromoethane
1,2-Dibromo-3-chloropropane
Isopropylbenzene
1,2,3-Trichlorobenzene
1,2,4-Trichlorobenzene
Methyl Acetate
Cyclohexane
1,4-Dioxane
Methyl cyclohexane
1,1,2-Trichloro-1,2,2-Trifluoroethane
Parameter Result Dilution Factor
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Qualifier Units RL
Volatile Organics by GC/MS - Westborough Lab
SAMPLE RESULTS
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
2.5
2.5
2.5
2.5
5.0
5.0
5.0
5.0
5.0
5.0
2.5
2.0
2.5
2.5
2.5
2.5
2.0
10
250
10
2.5
1,2-Dichloroethane-d4
Toluene-d8
4-Bromofluorobenzene
Dibromofluoromethane
79
89
96
103
70-130
70-130
70-130
70-130
Acceptance CriteriaSurrogate % Recovery Qualifier
05/28/13
TWP-1Client ID:05/16/13 11:50Date Collected:05/17/13Date Received:
PEMBERTON, NJSample Location:
L1308954-08Lab ID:
Field Prep: Not Specified
No Tentatively Identified Compounds ND ug/l 1
Tentatively Identified Compounds
MDL
0.70
0.70
0.70
0.70
1.0
1.0
1.0
1.0
1.0
1.0
0.70
0.65
0.70
0.70
0.70
0.70
0.65
0.70
76.
0.29
0.70
Serial_No:05281316:15
Page 15 of 75
1,4-Dioxane
Parameter Result Dilution Factor
ND ug/l 1
Qualifier Units RL
Volatile Organics by GC/MS-SIM - Westborough Lab
SAMPLE RESULTS
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
3.0
05/28/13
TWP-1Client ID:05/16/13 11:50Date Collected:05/17/13Date Received:
PEMBERTON, NJSample Location:
L1308954-08Lab ID:
Field Prep: Not SpecifiedMatrix: WaterAnalytical Method:Analytical Date:Analyst:
1,8260C-SIM(M)05/23/13 00:21PD
MDL
0.76
Serial_No:05281316:15
Page 16 of 75
1,2-Dibromoethane
1,2-Dibromo-3-chloropropane
Parameter Result Dilution Factor
ND
ND
ug/l
ug/l
1
1
Qualifier Units RL
Microextractables by GC - Westborough Lab
SAMPLE RESULTS
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
0.011
0.011
05/28/13
TWP-2Client ID:05/16/13 12:13Date Collected:05/17/13Date Received:
PEMBERTON, NJSample Location:
L1308954-09Lab ID:
Field Prep: Not SpecifiedMatrix: WaterAnalytical Method:Analytical Date:Analyst:
1,801105/25/13 00:43SR
Extraction Date: 05/24/13 13:00
MDL
0.003
0.004
Serial_No:05281316:15
Page 17 of 75
Methylene chloride
1,1-Dichloroethane
Chloroform
Carbon tetrachloride
1,2-Dichloropropane
Dibromochloromethane
1,1,2-Trichloroethane
Tetrachloroethene
Chlorobenzene
Trichlorofluoromethane
1,2-Dichloroethane
1,1,1-Trichloroethane
Bromodichloromethane
trans-1,3-Dichloropropene
cis-1,3-Dichloropropene
Bromoform
1,1,2,2-Tetrachloroethane
Benzene
Toluene
Ethylbenzene
Chloromethane
Bromomethane
Vinyl chloride
Chloroethane
1,1-Dichloroethene
trans-1,2-Dichloroethene
Trichloroethene
1,2-Dichlorobenzene
1,3-Dichlorobenzene
1,4-Dichlorobenzene
Methyl tert butyl ether
Parameter Result Dilution Factor
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Qualifier Units RL
Volatile Organics by GC/MS - Westborough Lab
SAMPLE RESULTS
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
2.5
2.5
2.5
0.50
1.0
0.50
1.5
0.50
2.5
2.5
0.50
2.5
0.50
0.50
0.50
2.0
0.50
0.50
2.5
2.5
2.5
2.5
1.0
2.5
0.50
2.5
0.50
2.5
2.5
2.5
2.5
05/28/13
TWP-2Client ID:05/16/13 12:13Date Collected:05/17/13Date Received:
PEMBERTON, NJSample Location:
L1308954-09Lab ID:
Field Prep: Not SpecifiedMatrix: WaterAnalytical Method:Analytical Date:Analyst:
1,8260C05/23/13 16:52PD
MDL
0.70
0.70
0.70
0.16
0.30
0.19
0.50
0.18
0.70
0.70
0.16
0.70
0.19
0.16
0.14
0.65
0.19
0.19
0.70
0.70
0.70
0.70
0.33
0.70
0.18
0.70
0.17
0.70
0.70
0.70
0.70
Serial_No:05281316:15
Page 18 of 75
p/m-Xylene
o-Xylene
cis-1,2-Dichloroethene
Styrene
Dichlorodifluoromethane
Acetone
Carbon disulfide
2-Butanone
4-Methyl-2-pentanone
2-Hexanone
Bromochloromethane
1,2-Dibromoethane
1,2-Dibromo-3-chloropropane
Isopropylbenzene
1,2,3-Trichlorobenzene
1,2,4-Trichlorobenzene
Methyl Acetate
Cyclohexane
1,4-Dioxane
Methyl cyclohexane
1,1,2-Trichloro-1,2,2-Trifluoroethane
Parameter Result Dilution Factor
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Qualifier Units RL
Volatile Organics by GC/MS - Westborough Lab
SAMPLE RESULTS
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
2.5
2.5
2.5
2.5
5.0
5.0
5.0
5.0
5.0
5.0
2.5
2.0
2.5
2.5
2.5
2.5
2.0
10
250
10
2.5
05/28/13
TWP-2Client ID:05/16/13 12:13Date Collected:05/17/13Date Received:
PEMBERTON, NJSample Location:
L1308954-09Lab ID:
Field Prep: Not Specified
Propene
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
NJ
J
J
J
J
J
J
J
J
20
3.3
13
1.3
1.4
4.8
1.9
3.7
2.6
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
1
1
1
1
1
1
1
1
1
Tentatively Identified Compounds
MDL
0.70
0.70
0.70
0.70
1.0
1.0
1.0
1.0
1.0
1.0
0.70
0.65
0.70
0.70
0.70
0.70
0.65
0.70
76.
0.29
0.70
Serial_No:05281316:15
Page 19 of 75
Parameter Result Dilution FactorQualifier Units RL
Volatile Organics by GC/MS - Westborough Lab
SAMPLE RESULTS
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
1,2-Dichloroethane-d4
Toluene-d8
4-Bromofluorobenzene
Dibromofluoromethane
92
87
90
101
70-130
70-130
70-130
70-130
Acceptance CriteriaSurrogate % Recovery Qualifier
05/28/13
TWP-2Client ID:05/16/13 12:13Date Collected:05/17/13Date Received:
PEMBERTON, NJSample Location:
L1308954-09Lab ID:
Field Prep: Not Specified
MDL
Serial_No:05281316:15
Page 20 of 75
1,4-Dioxane
Parameter Result Dilution Factor
ND ug/l 1
Qualifier Units RL
Volatile Organics by GC/MS-SIM - Westborough Lab
SAMPLE RESULTS
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
3.0
05/28/13
TWP-2Client ID:05/16/13 12:13Date Collected:05/17/13Date Received:
PEMBERTON, NJSample Location:
L1308954-09Lab ID:
Field Prep: Not SpecifiedMatrix: WaterAnalytical Method:Analytical Date:Analyst:
1,8260C-SIM(M)05/23/13 16:52PD
MDL
0.76
Serial_No:05281316:15
Page 21 of 75
Method Blank AnalysisBatch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
05/20/13 10:411,8260CAnalytical Method:
Analytical Date:
05/28/13
Analyst: BN
1,2-Dibromo-3-chloropropane
1,4-Dioxane
1,2-Dibromoethane
Methylene chloride
1,1-Dichloroethane
Chloroform
Carbon tetrachloride
1,2-Dichloropropane
Dibromochloromethane
1,1,2-Trichloroethane
2-Chloroethylvinyl ether
Tetrachloroethene
Chlorobenzene
Trichlorofluoromethane
1,2-Dichloroethane
1,1,1-Trichloroethane
Bromodichloromethane
trans-1,3-Dichloropropene
cis-1,3-Dichloropropene
1,1-Dichloropropene
Bromoform
1,1,2,2-Tetrachloroethane
Benzene
Toluene
Ethylbenzene
Chloromethane
Bromomethane
Vinyl chloride
Chloroethane
1,1-Dichloroethene
trans-1,2-Dichloroethene
Parameter Result
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
0.00020
ND
ND
ND
ND
ND
ND
ND
RL
0.0050
0.10
0.0040
0.0050
0.0015
0.0015
0.0010
0.0035
0.0010
0.0015
0.020
0.0010
0.0010
0.0050
0.0010
0.0010
0.0010
0.0010
0.0010
0.0050
0.0040
0.0010
0.0010
0.0015
0.0010
0.0050
0.0020
0.0020
0.0020
0.0010
0.0015
J
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
UnitsQualifier
Volatile Organics by GC/MS-5035 - Westborough Lab for sample(s): 01-02 Batch: WG609456-3
MDL
0.00079
0.017
0.00018
0.0020
0.00018
0.00037
0.00021
0.00023
0.00031
0.00030
0.00062
0.00014
0.00035
0.00012
0.00015
0.00011
0.00023
0.00012
0.00013
0.00046
0.00041
0.00017
0.00012
0.00011
0.00015
0.00078
0.00034
0.00014
0.00032
0.00020
0.00021
Serial_No:05281316:15
Page 22 of 75
Method Blank AnalysisBatch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
05/20/13 10:411,8260CAnalytical Method:
Analytical Date:
05/28/13
Analyst: BN
Trichloroethene
1,2-Dichlorobenzene
1,3-Dichlorobenzene
1,4-Dichlorobenzene
Methyl tert butyl ether
p/m-Xylene
o-Xylene
cis-1,2-Dichloroethene
Dibromomethane
1,4-Dichlorobutane
1,2,3-Trichloropropane
Styrene
Dichlorodifluoromethane
Acetone
Carbon disulfide
2-Butanone
Vinyl acetate
4-Methyl-2-pentanone
2-Hexanone
Ethyl methacrylate
Acrolein
Acrylonitrile
Bromochloromethane
Tetrahydrofuran
2,2-Dichloropropane
1,3-Dichloropropane
1,1,1,2-Tetrachloroethane
Bromobenzene
n-Butylbenzene
sec-Butylbenzene
tert-Butylbenzene
Parameter Result
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
RL
0.0010
0.0050
0.0050
0.0050
0.0020
0.0020
0.0020
0.0010
0.010
0.010
0.010
0.0020
0.010
0.036
0.010
0.010
0.010
0.010
0.010
0.010
0.025
0.0040
0.0050
0.020
0.0050
0.0050
0.0010
0.0050
0.0010
0.0010
0.0050
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
UnitsQualifier
Volatile Organics by GC/MS-5035 - Westborough Lab for sample(s): 01-02 Batch: WG609456-3
MDL
0.00015
0.00018
0.00018
0.00024
0.00010
0.00032
0.00027
0.00015
0.00016
0.0010
0.00022
0.00031
0.00022
0.0031
0.0020
0.00036
0.00048
0.00024
0.00019
0.00076
0.0092
0.00024
0.00020
0.00038
0.00022
0.00017
0.00032
0.00021
0.00020
0.00020
0.00056
Serial_No:05281316:15
Page 23 of 75
Method Blank AnalysisBatch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
05/20/13 10:411,8260CAnalytical Method:
Analytical Date:
05/28/13
Analyst: BN
o-Chlorotoluene
p-Chlorotoluene
Hexachlorobutadiene
Isopropylbenzene
p-Isopropyltoluene
Naphthalene
n-Propylbenzene
1,2,3-Trichlorobenzene
1,2,4-Trichlorobenzene
1,3,5-Trimethylbenzene
1,2,4-Trimethylbenzene
trans-1,4-Dichloro-2-butene
Ethyl ether
Methyl Acetate
Ethyl Acetate
Isopropyl Ether
Cyclohexane
tert-Butyl Alcohol
Ethyl-Tert-Butyl-Ether
Tertiary-Amyl Methyl Ether
Methyl cyclohexane
1,1,2-Trichloro-1,2,2-Trifluoroethane
Parameter Result
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
RL
0.0050
0.0050
0.0050
0.0010
0.0010
0.0050
0.0010
0.0050
0.0050
0.0050
0.0050
0.0050
0.0050
0.0040
0.020
0.0040
0.020
0.10
0.0040
0.0040
0.0040
0.020
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
UnitsQualifier
Volatile Organics by GC/MS-5035 - Westborough Lab for sample(s): 01-02 Batch: WG609456-3
Unknown J0.0034 mg/kg
Tentatively Identified Compounds
MDL
0.00016
0.00015
0.00042
0.00017
0.00019
0.00077
0.00012
0.00017
0.00079
0.00014
0.00057
0.00045
0.00026
0.00076
0.00082
0.00014
0.0011
0.00091
0.00042
0.00058
0.0013
0.00027
Serial_No:05281316:15
Page 24 of 75
Method Blank AnalysisBatch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
05/20/13 10:411,8260CAnalytical Method:
Analytical Date:
05/28/13
Analyst: BN
Parameter Result RLUnitsQualifier
Volatile Organics by GC/MS-5035 - Westborough Lab for sample(s): 01-02 Batch: WG609456-3
1,2-Dichloroethane-d4
Toluene-d8
4-Bromofluorobenzene
Dibromofluoromethane
109
99
105
105
70-130
70-130
70-130
70-130
Surrogate %Recovery QualifierAcceptance
Criteria
MDL
Serial_No:05281316:15
Page 25 of 75
Method Blank AnalysisBatch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
05/22/13 13:561,8260CAnalytical Method:
Analytical Date:
05/28/13
Analyst: PD
Methylene chloride
1,1-Dichloroethane
Chloroform
Carbon tetrachloride
1,2-Dichloropropane
Dibromochloromethane
1,1,2-Trichloroethane
Tetrachloroethene
Chlorobenzene
Trichlorofluoromethane
1,2-Dichloroethane
1,1,1-Trichloroethane
Bromodichloromethane
trans-1,3-Dichloropropene
cis-1,3-Dichloropropene
Bromoform
1,1,2,2-Tetrachloroethane
Benzene
Toluene
Ethylbenzene
Chloromethane
Bromomethane
Vinyl chloride
Chloroethane
1,1-Dichloroethene
trans-1,2-Dichloroethene
Trichloroethene
1,2-Dichlorobenzene
1,3-Dichlorobenzene
1,4-Dichlorobenzene
Methyl tert butyl ether
Parameter Result
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
RL
2.5
2.5
2.5
0.50
1.0
0.50
1.5
0.50
2.5
2.5
0.50
2.5
0.50
0.50
0.50
2.0
0.50
0.50
2.5
2.5
2.5
2.5
1.0
2.5
0.50
2.5
0.50
2.5
2.5
2.5
2.5
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
UnitsQualifier
Volatile Organics by GC/MS - Westborough Lab for sample(s): 08 Batch: WG610254-3
MDL
0.70
0.70
0.70
0.16
0.30
0.19
0.50
0.18
0.70
0.70
0.16
0.70
0.19
0.16
0.14
0.65
0.19
0.19
0.70
0.70
0.70
0.70
0.33
0.70
0.18
0.70
0.17
0.70
0.70
0.70
0.70
Serial_No:05281316:15
Page 26 of 75
Method Blank AnalysisBatch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
05/22/13 13:561,8260CAnalytical Method:
Analytical Date:
05/28/13
Analyst: PD
p/m-Xylene
o-Xylene
cis-1,2-Dichloroethene
Styrene
Dichlorodifluoromethane
Acetone
Carbon disulfide
2-Butanone
4-Methyl-2-pentanone
2-Hexanone
Bromochloromethane
1,2-Dibromoethane
1,2-Dibromo-3-chloropropane
Isopropylbenzene
1,2,3-Trichlorobenzene
1,2,4-Trichlorobenzene
Methyl Acetate
Cyclohexane
tert-Butyl Alcohol
1,4-Dioxane
Methyl cyclohexane
1,1,2-Trichloro-1,2,2-Trifluoroethane
Parameter Result
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
RL
2.5
2.5
2.5
2.5
5.0
5.0
5.0
5.0
5.0
5.0
2.5
2.0
2.5
2.5
2.5
2.5
2.0
10
10
250
10
2.5
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
UnitsQualifier
Volatile Organics by GC/MS - Westborough Lab for sample(s): 08 Batch: WG610254-3
No Tentatively Identified Compounds ND ug/l
Tentatively Identified Compounds
MDL
0.70
0.70
0.70
0.70
1.0
1.0
1.0
1.0
1.0
1.0
0.70
0.65
0.70
0.70
0.70
0.70
0.65
0.70
0.90
76.
0.29
0.70
Serial_No:05281316:15
Page 27 of 75
Method Blank AnalysisBatch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
05/22/13 13:561,8260CAnalytical Method:
Analytical Date:
05/28/13
Analyst: PD
Parameter Result RLUnitsQualifier
Volatile Organics by GC/MS - Westborough Lab for sample(s): 08 Batch: WG610254-3
1,2-Dichloroethane-d4
Toluene-d8
4-Bromofluorobenzene
Dibromofluoromethane
83
88
94
97
70-130
70-130
70-130
70-130
Surrogate %Recovery QualifierAcceptance
Criteria
MDL
Serial_No:05281316:15
Page 28 of 75
Method Blank AnalysisBatch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
05/22/13 13:561,8260C-SIM(M)Analytical Method:
Analytical Date:
05/28/13
Analyst: PD
1,4-Dioxane
Parameter Result
ND
RL
3.0ug/l
UnitsQualifier
Volatile Organics by GC/MS-SIM - Westborough Lab for sample(s): 08 Batch: WG610255-3
MDL
0.76
Serial_No:05281316:15
Page 29 of 75
Method Blank AnalysisBatch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
05/23/13 14:041,8260C-SIM(M)Analytical Method:
Analytical Date:
05/28/13
Analyst: PD
1,4-Dioxane
Parameter Result
ND
RL
3.0ug/l
UnitsQualifier
Volatile Organics by GC/MS-SIM - Westborough Lab for sample(s): 09 Batch: WG610273-3
MDL
0.76
Serial_No:05281316:15
Page 30 of 75
Method Blank AnalysisBatch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
05/23/13 14:041,8260CAnalytical Method:
Analytical Date:
05/28/13
Analyst: PD
Methylene chloride
1,1-Dichloroethane
Chloroform
Carbon tetrachloride
1,2-Dichloropropane
Dibromochloromethane
1,1,2-Trichloroethane
Tetrachloroethene
Chlorobenzene
Trichlorofluoromethane
1,2-Dichloroethane
1,1,1-Trichloroethane
Bromodichloromethane
trans-1,3-Dichloropropene
cis-1,3-Dichloropropene
Bromoform
1,1,2,2-Tetrachloroethane
Benzene
Toluene
Ethylbenzene
Chloromethane
Bromomethane
Vinyl chloride
Chloroethane
1,1-Dichloroethene
trans-1,2-Dichloroethene
Trichloroethene
1,2-Dichlorobenzene
1,3-Dichlorobenzene
1,4-Dichlorobenzene
Methyl tert butyl ether
Parameter Result
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
RL
2.5
2.5
2.5
0.50
1.0
0.50
1.5
0.50
2.5
2.5
0.50
2.5
0.50
0.50
0.50
2.0
0.50
0.50
2.5
2.5
2.5
2.5
1.0
2.5
0.50
2.5
0.50
2.5
2.5
2.5
2.5
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
UnitsQualifier
Volatile Organics by GC/MS - Westborough Lab for sample(s): 09 Batch: WG610277-3
MDL
0.70
0.70
0.70
0.16
0.30
0.19
0.50
0.18
0.70
0.70
0.16
0.70
0.19
0.16
0.14
0.65
0.19
0.19
0.70
0.70
0.70
0.70
0.33
0.70
0.18
0.70
0.17
0.70
0.70
0.70
0.70
Serial_No:05281316:15
Page 31 of 75
Method Blank AnalysisBatch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
05/23/13 14:041,8260CAnalytical Method:
Analytical Date:
05/28/13
Analyst: PD
p/m-Xylene
o-Xylene
cis-1,2-Dichloroethene
Styrene
Dichlorodifluoromethane
Acetone
Carbon disulfide
2-Butanone
4-Methyl-2-pentanone
2-Hexanone
Bromochloromethane
1,2-Dibromoethane
1,2-Dibromo-3-chloropropane
Isopropylbenzene
1,2,3-Trichlorobenzene
1,2,4-Trichlorobenzene
Methyl Acetate
Cyclohexane
Methyl cyclohexane
1,1,2-Trichloro-1,2,2-Trifluoroethane
Parameter Result
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
RL
2.5
2.5
2.5
2.5
5.0
5.0
5.0
5.0
5.0
5.0
2.5
2.0
2.5
2.5
2.5
2.5
2.0
10
10
2.5
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
ug/l
UnitsQualifier
Volatile Organics by GC/MS - Westborough Lab for sample(s): 09 Batch: WG610277-3
No Tentatively Identified Compounds ND ug/l
Tentatively Identified Compounds
MDL
0.70
0.70
0.70
0.70
1.0
1.0
1.0
1.0
1.0
1.0
0.70
0.65
0.70
0.70
0.70
0.70
0.65
0.70
0.29
0.70
Serial_No:05281316:15
Page 32 of 75
Method Blank AnalysisBatch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
05/23/13 14:041,8260CAnalytical Method:
Analytical Date:
05/28/13
Analyst: PD
Parameter Result RLUnitsQualifier
Volatile Organics by GC/MS - Westborough Lab for sample(s): 09 Batch: WG610277-3
1,2-Dichloroethane-d4
Toluene-d8
4-Bromofluorobenzene
Dibromofluoromethane
87
91
98
84
70-130
70-130
70-130
70-130
Surrogate %Recovery QualifierAcceptance
Criteria
MDL
Serial_No:05281316:15
Page 33 of 75
Method Blank AnalysisBatch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
05/24/13 23:261,8011Analytical Method:
Analytical Date: Extraction Date: 05/24/13 13:00
05/28/13
Analyst: SR
1,2-Dibromoethane
1,2-Dibromo-3-chloropropane
Parameter Result
ND
ND
RL
0.010
0.010
ug/l
ug/l
UnitsQualifier
Microextractables by GC - Westborough Lab for sample(s): 08-09 Batch: WG610498-1
MDL
0.003
0.004
Serial_No:05281316:15
Page 34 of 75
1,2-Dibromo-3-chloropropane
1,4-Dioxane
1,2-Dibromoethane
Methylene chloride
1,1-Dichloroethane
Chloroform
Carbon tetrachloride
1,2-Dichloropropane
Dibromochloromethane
1,1,2-Trichloroethane
2-Chloroethylvinyl ether
Tetrachloroethene
Chlorobenzene
Trichlorofluoromethane
1,2-Dichloroethane
1,1,1-Trichloroethane
Bromodichloromethane
trans-1,3-Dichloropropene
cis-1,3-Dichloropropene
1,1-Dichloropropene
Bromoform
88
98
99
98
90
94
88
90
95
103
100
85
96
104
100
89
96
102
94
89
89
88
106
100
104
91
94
87
92
95
106
105
86
97
101
101
89
97
106
95
89
95
68-130
65-136
70-130
70-130
70-130
70-130
70-130
70-130
70-130
70-130
70-130
70-130
70-139
70-130
70-130
70-130
70-130
70-130
70-130
70-130
0
8
1
6
2
0
1
2
0
3
5
1
1
3
1
0
1
4
2
1
6
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
ParameterLCS
%RecoveryLCSD
%Recovery%Recovery
Limits RPD RPD Limits
Volatile Organics by GC/MS-5035 - Westborough Lab Associated sample(s): 01-02 Batch: WG609456-1 WG609456-2
Lab Control Sample AnalysisBatch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
05/28/13
Qual Qual Qual
Serial_No:05281316:15
Page 35 of 75
1,1,2,2-Tetrachloroethane
Benzene
Toluene
Ethylbenzene
Chloromethane
Bromomethane
Vinyl chloride
Chloroethane
1,1-Dichloroethene
trans-1,2-Dichloroethene
Trichloroethene
1,2-Dichlorobenzene
1,3-Dichlorobenzene
1,4-Dichlorobenzene
Methyl tert butyl ether
p/m-Xylene
o-Xylene
cis-1,2-Dichloroethene
Dibromomethane
1,4-Dichlorobutane
1,2,3-Trichloropropane
102
90
95
95
71
114
102
114
85
87
89
96
96
96
91
91
89
88
97
101
103
106
91
96
96
69
116
100
114
86
87
89
91
97
98
95
96
90
90
99
104
109
70-130
70-130
70-130
70-130
52-130
57-147
67-130
50-151
65-135
70-130
70-130
70-130
70-130
70-130
66-130
70-130
70-130
70-130
70-130
70-130
68-130
4
2
2
1
2
2
2
0
1
1
0
6
0
2
4
5
1
2
2
3
6
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
ParameterLCS
%RecoveryLCSD
%Recovery%Recovery
Limits RPD RPD Limits
Volatile Organics by GC/MS-5035 - Westborough Lab Associated sample(s): 01-02 Batch: WG609456-1 WG609456-2
Lab Control Sample AnalysisBatch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
05/28/13
Qual Qual Qual
Serial_No:05281316:15
Page 36 of 75
Styrene
Dichlorodifluoromethane
Acetone
Carbon disulfide
2-Butanone
Vinyl acetate
4-Methyl-2-pentanone
2-Hexanone
Ethyl methacrylate
Acrolein
Acrylonitrile
Bromochloromethane
Tetrahydrofuran
2,2-Dichloropropane
1,3-Dichloropropane
1,1,1,2-Tetrachloroethane
Bromobenzene
n-Butylbenzene
sec-Butylbenzene
tert-Butylbenzene
o-Chlorotoluene
94
86
129
90
119
96
84
96
96
69
86
90
83
87
103
94
82
99
97
95
97
98
83
129
89
118
101
90
101
100
76
89
92
74
87
107
96
93
99
96
93
102
70-130
30-146
54-140
59-130
70-130
70-130
70-130
70-130
70-130
70-130
70-130
66-130
70-130
69-130
70-130
70-130
70-130
70-130
70-130
70-130
5
4
0
0
1
5
6
5
4
9
3
1
11
0
4
2
13
0
1
2
5
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
ParameterLCS
%RecoveryLCSD
%Recovery%Recovery
Limits RPD RPD Limits
Volatile Organics by GC/MS-5035 - Westborough Lab Associated sample(s): 01-02 Batch: WG609456-1 WG609456-2
Lab Control Sample AnalysisBatch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
05/28/13
Qual Qual Qual
Serial_No:05281316:15
Page 37 of 75
p-Chlorotoluene
Hexachlorobutadiene
Isopropylbenzene
p-Isopropyltoluene
Naphthalene
n-Propylbenzene
1,2,3-Trichlorobenzene
1,2,4-Trichlorobenzene
1,3,5-Trimethylbenzene
1,2,4-Trimethylbenzene
trans-1,4-Dichloro-2-butene
Ethyl ether
Methyl Acetate
Ethyl Acetate
Isopropyl Ether
Cyclohexane
tert-Butyl Alcohol
Ethyl-Tert-Butyl-Ether
Methyl cyclohexane
1,1,2-Trichloro-1,2,2-Trifluoroethane
99
81
91
93
89
97
81
86
96
98
99
113
93
77
91
84
85
91
88
93
100
84
90
93
95
97
91
90
97
98
105
119
97
89
94
82
92
94
88
91
70-130
67-130
70-130
70-130
70-130
70-130
70-130
70-130
70-130
70-130
70-130
67-130
51-146
66-130
59-142
67-130
70-130
70-130
50-139
1
3
1
0
7
0
12
4
1
0
6
5
4
14
4
3
8
3
1
2
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
ParameterLCS
%RecoveryLCSD
%Recovery%Recovery
Limits RPD RPD Limits
Volatile Organics by GC/MS-5035 - Westborough Lab Associated sample(s): 01-02 Batch: WG609456-1 WG609456-2
Lab Control Sample AnalysisBatch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
05/28/13
Qual Qual Qual
Serial_No:05281316:15
Page 38 of 75
Methylene chloride
1,1-Dichloroethane
Chloroform
Carbon tetrachloride
1,2-Dichloropropane
Dibromochloromethane
1,1,2-Trichloroethane
Tetrachloroethene
Chlorobenzene
99
96
106
104
106
100
91
98
96
89
85
95
90
95
91
84
86
88
70-130
70-130
70-130
63-132
70-130
63-130
70-130
70-130
75-130
11
12
11
14
11
9
8
13
9
20
20
20
20
20
20
20
20
20
ParameterLCS
%RecoveryLCSD
%Recovery%Recovery
Limits RPD RPD Limits
Volatile Organics by GC/MS-5035 - Westborough Lab Associated sample(s): 01-02 Batch: WG609456-1 WG609456-2
Volatile Organics by GC/MS - Westborough Lab Associated sample(s): 08 Batch: WG610254-1 WG610254-2
Lab Control Sample AnalysisBatch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
1,2-Dichloroethane-d4
Toluene-d8
4-Bromofluorobenzene
Dibromofluoromethane
107
107
104
103
70-130
70-130
70-130
70-130
108
108
104
104
Surrogate Qual%Recovery Qual%RecoveryLCS LCSD
05/28/13
AcceptanceCriteria
Qual Qual Qual
Serial_No:05281316:15
Page 39 of 75
Trichlorofluoromethane
1,2-Dichloroethane
1,1,1-Trichloroethane
Bromodichloromethane
trans-1,3-Dichloropropene
cis-1,3-Dichloropropene
Bromoform
1,1,2,2-Tetrachloroethane
Benzene
Toluene
Ethylbenzene
Chloromethane
Bromomethane
Vinyl chloride
Chloroethane
1,1-Dichloroethene
trans-1,2-Dichloroethene
Trichloroethene
1,2-Dichlorobenzene
1,3-Dichlorobenzene
1,4-Dichlorobenzene
106
102
101
99
80
98
87
83
101
93
86
98
112
89
90
96
93
104
96
96
94
89
90
88
89
78
87
76
76
90
83
79
88
97
80
79
85
88
90
83
80
82
62-150
70-130
67-130
67-130
70-130
70-130
54-136
67-130
70-130
70-130
70-130
64-130
39-139
55-140
55-138
61-145
70-130
70-130
70-130
70-130
70-130
17
13
14
11
3
12
13
9
12
11
8
11
14
11
13
12
6
14
15
18
14
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
ParameterLCS
%RecoveryLCSD
%Recovery%Recovery
Limits RPD RPD Limits
Volatile Organics by GC/MS - Westborough Lab Associated sample(s): 08 Batch: WG610254-1 WG610254-2
Lab Control Sample AnalysisBatch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
05/28/13
Qual Qual Qual
Serial_No:05281316:15
Page 40 of 75
Methyl tert butyl ether
p/m-Xylene
o-Xylene
cis-1,2-Dichloroethene
Styrene
Dichlorodifluoromethane
Acetone
Carbon disulfide
2-Butanone
4-Methyl-2-pentanone
2-Hexanone
Bromochloromethane
1,2-Dibromoethane
1,2-Dibromo-3-chloropropane
Isopropylbenzene
1,2,3-Trichlorobenzene
1,2,4-Trichlorobenzene
Methyl Acetate
Cyclohexane
tert-Butyl Alcohol
1,4-Dioxane
100
93
94
112
92
96
68
88
75
100
80
120
97
88
84
95
102
93
88
77
0
90
85
86
101
85
82
59
75
70
103
75
93
93
80
71
87
90
88
76
80
0
63-130
70-130
70-130
70-130
70-130
36-147
58-148
51-130
63-138
59-130
57-130
70-130
70-130
41-144
70-130
70-130
70-130
70-130
70-130
70-130
56-162
11
9
9
10
8
16
14
16
7
3
6
25
4
10
17
9
13
6
15
4
NC
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
ParameterLCS
%RecoveryLCSD
%Recovery%Recovery
Limits RPD RPD Limits
Volatile Organics by GC/MS - Westborough Lab Associated sample(s): 08 Batch: WG610254-1 WG610254-2
Lab Control Sample AnalysisBatch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
05/28/13
Qual Qual
Q Q
Qual
Q
Serial_No:05281316:15
Page 41 of 75
Methyl cyclohexane
1,1,2-Trichloro-1,2,2-Trifluoroethane
1,4-Dioxane
78
96
100
66
82
118
70-130
70-130
70-130
17
16
17
20
20
25
ParameterLCS
%RecoveryLCSD
%Recovery%Recovery
Limits RPD RPD Limits
Volatile Organics by GC/MS - Westborough Lab Associated sample(s): 08 Batch: WG610254-1 WG610254-2
Volatile Organics by GC/MS-SIM - Westborough Lab Associated sample(s): 08 Batch: WG610255-1 WG610255-2
Lab Control Sample AnalysisBatch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
1,2-Dichloroethane-d4
Toluene-d8
4-Bromofluorobenzene
Dibromofluoromethane
88
87
93
106
70-130
70-130
70-130
70-130
90
89
85
98
Surrogate Qual%Recovery Qual%RecoveryLCS LCSD
05/28/13
AcceptanceCriteria
Qual Qual
Q
Qual
Serial_No:05281316:15
Page 42 of 75
1,4-Dioxane
Methylene chloride
1,1-Dichloroethane
Chloroform
Carbon tetrachloride
1,2-Dichloropropane
Dibromochloromethane
1,1,2-Trichloroethane
Tetrachloroethene
Chlorobenzene
124
97
93
104
110
106
94
87
110
95
115
90
90
101
100
103
87
79
90
89
70-130
70-130
70-130
70-130
63-132
70-130
63-130
70-130
70-130
75-130
8
7
3
3
10
3
8
10
20
7
25
20
20
20
20
20
20
20
20
20
ParameterLCS
%RecoveryLCSD
%Recovery%Recovery
Limits RPD RPD Limits
Volatile Organics by GC/MS-SIM - Westborough Lab Associated sample(s): 09 Batch: WG610273-1 WG610273-2
Volatile Organics by GC/MS - Westborough Lab Associated sample(s): 09 Batch: WG610277-1 WG610277-2
Lab Control Sample AnalysisBatch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
05/28/13
Qual Qual Qual
Serial_No:05281316:15
Page 43 of 75
Trichlorofluoromethane
1,2-Dichloroethane
1,1,1-Trichloroethane
Bromodichloromethane
trans-1,3-Dichloropropene
cis-1,3-Dichloropropene
Bromoform
1,1,2,2-Tetrachloroethane
Benzene
Toluene
Ethylbenzene
Chloromethane
Bromomethane
Vinyl chloride
Chloroethane
1,1-Dichloroethene
trans-1,2-Dichloroethene
Trichloroethene
1,2-Dichlorobenzene
1,3-Dichlorobenzene
1,4-Dichlorobenzene
112
104
107
98
80
94
81
86
104
93
92
97
93
97
87
94
105
110
95
93
94
103
100
96
95
74
93
81
78
97
84
80
93
87
85
80
90
91
100
92
92
91
62-150
70-130
67-130
67-130
70-130
70-130
54-136
67-130
70-130
70-130
70-130
64-130
39-139
55-140
55-138
61-145
70-130
70-130
70-130
70-130
70-130
8
4
11
3
8
1
0
10
7
10
14
4
7
13
8
4
14
10
3
1
3
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
ParameterLCS
%RecoveryLCSD
%Recovery%Recovery
Limits RPD RPD Limits
Volatile Organics by GC/MS - Westborough Lab Associated sample(s): 09 Batch: WG610277-1 WG610277-2
Lab Control Sample AnalysisBatch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
05/28/13
Qual Qual Qual
Serial_No:05281316:15
Page 44 of 75
Methyl tert butyl ether
p/m-Xylene
o-Xylene
cis-1,2-Dichloroethene
Styrene
Dichlorodifluoromethane
Acetone
Carbon disulfide
2-Butanone
4-Methyl-2-pentanone
2-Hexanone
Bromochloromethane
1,2-Dibromoethane
1,2-Dibromo-3-chloropropane
Isopropylbenzene
1,2,3-Trichlorobenzene
1,2,4-Trichlorobenzene
Methyl Acetate
Cyclohexane
Methyl cyclohexane
1,1,2-Trichloro-1,2,2-Trifluoroethane
99
94
96
113
93
100
70
88
82
114
84
119
98
81
88
99
100
97
106
109
107
90
84
88
112
85
100
55
81
72
95
68
113
87
75
81
100
95
87
93
85
98
63-130
70-130
70-130
70-130
70-130
36-147
58-148
51-130
63-138
59-130
57-130
70-130
70-130
41-144
70-130
70-130
70-130
70-130
70-130
70-130
70-130
10
11
9
1
9
0
24
8
13
18
21
5
12
8
8
1
5
11
13
25
9
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
ParameterLCS
%RecoveryLCSD
%Recovery%Recovery
Limits RPD RPD Limits
Volatile Organics by GC/MS - Westborough Lab Associated sample(s): 09 Batch: WG610277-1 WG610277-2
Lab Control Sample AnalysisBatch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
05/28/13
Qual Qual
Q
Qual
Q
Q
Q
Serial_No:05281316:15
Page 45 of 75
1,2-Dibromoethane
1,2-Dibromo-3-chloropropane
100
100
-
-
70-130
70-130
-
-
20
20
ParameterLCS
%RecoveryLCSD
%Recovery%Recovery
Limits RPD RPD Limits
Volatile Organics by GC/MS - Westborough Lab Associated sample(s): 09 Batch: WG610277-1 WG610277-2
Microextractables by GC - Westborough Lab Associated sample(s): 08-09 Batch: WG610498-2
Lab Control Sample AnalysisBatch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
1,2-Dichloroethane-d4
Toluene-d8
4-Bromofluorobenzene
Dibromofluoromethane
90
85
88
110
70-130
70-130
70-130
70-130
88
83
92
105
Surrogate Qual%Recovery Qual%RecoveryLCS LCSD
05/28/13
AcceptanceCriteria
Qual Qual Qual
Serial_No:05281316:15
Page 46 of 75
1,2-Dibromoethane ND 0.249 101 - - 70-130 - 20
ParameterNative Sample
MS Found
MS%Recovery
MSD Found
MSD %Recovery RPD
RPD Limits
Microextractables by GC - Westborough Lab Associated sample(s): 08-09 QC Batch ID: WG610498-3 QC Sample: L1308960-01 Client ID: MS Sample
0.246
MS Added
Matrix Spike AnalysisBatch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
05/28/13
RecoveryLimitsQual Qual Qual
Serial_No:05281316:15
Page 47 of 75
PETROLEUM HYDROCARBONS
Serial_No:05281316:15
Page 48 of 75
FF
Total EPH
Parameter Result Dilution Factor
375 mg/kg 1
Qualifier Units RL
NJ Extractable Petroleum Hydrocarbons (Total) - Westborough Lab
SAMPLE RESULTS
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
27.2
Chloro-Octadecane
o-Terphenyl
88
93
40-140
40-140
Acceptance CriteriaSurrogate % Recovery Qualifier
05/28/13
UST-3 8-8.5Client ID:05/16/13 11:22Date Collected:05/17/13Date Received:
PEMBERTON, NJSample Location:
L1308954-05Lab ID:
Field Prep: Not SpecifiedMatrix: Soil Extraction Method:Analytical Method:Analytical Date:Analyst:
103,NJDEP EPH05/21/13 16:28AR
EPA 3546Extraction Date: 05/18/13 13:09
85%Percent Solids:
MDL
27.2
Serial_No:05281316:15
Page 49 of 75
Total EPH
Parameter Result Dilution Factor
ND mg/kg 1
Qualifier Units RL
NJ Extractable Petroleum Hydrocarbons (Total) - Westborough Lab
SAMPLE RESULTS
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
27.8
Chloro-Octadecane
o-Terphenyl
84
78
40-140
40-140
Acceptance CriteriaSurrogate % Recovery Qualifier
05/28/13
UST-4 7.5-8Client ID:05/16/13 11:31Date Collected:05/17/13Date Received:
PEMBERTON, NJSample Location:
L1308954-06Lab ID:
Field Prep: Not SpecifiedMatrix: Soil Extraction Method:Analytical Method:Analytical Date:Analyst:
103,NJDEP EPH05/21/13 19:59AR
EPA 3546Extraction Date: 05/18/13 13:09
84%Percent Solids:
MDL
27.8
Serial_No:05281316:15
Page 50 of 75
Total EPH
Parameter Result Dilution Factor
40.8 mg/kg 1
Qualifier Units RL
NJ Extractable Petroleum Hydrocarbons (Total) - Westborough Lab
SAMPLE RESULTS
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
23.9
Chloro-Octadecane
o-Terphenyl
87
86
40-140
40-140
Acceptance CriteriaSurrogate % Recovery Qualifier
05/28/13
I-1Client ID:05/16/13 10:42Date Collected:05/17/13Date Received:
PEMBERTON, NJSample Location:
L1308954-07Lab ID:
Field Prep: Not SpecifiedMatrix: Soil Extraction Method:Analytical Method:Analytical Date:Analyst:
103,NJDEP EPH05/21/13 17:59AR
EPA 3546Extraction Date: 05/18/13 13:09
96%Percent Solids:
MDL
23.9
Serial_No:05281316:15
Page 51 of 75
Method Blank AnalysisBatch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
05/21/13 14:51103,NJDEP EPHAnalytical Method:
Analytical Date:Extraction Method: EPA 3546Extraction Date: 05/18/13 13:09
05/28/13
Analyst: AR
Total EPH
Parameter Result
ND
RL
23.3mg/kg
UnitsQualifier
NJ Extractable Petroleum Hydrocarbons (Total) - Westborough Lab for sample(s): 05-07 Batch: WG609036-1
Chloro-Octadecane
o-Terphenyl
76
72
40-140
40-140
Surrogate %Recovery QualifierAcceptance
Criteria
MDL
23.3
Serial_No:05281316:15
Page 52 of 75
Total EPH
Nonane (C9)
Decane (C10)
Dodecane (C12)
Tetradecane (C14)
Hexadecane (C16)
Octadecane (C18)
Eicosane (C20)
Heneicosane (C21)
Docosane (C22)
Tetracosane (C24)
Hexacosane (C26)
Octacosane (C28)
Triacontane (C30)
Dotriacontane (C32)
Tetratriacontane (C34)
Hexatriacontane (C36)
Octatriacontane (C38)
Tetracontane (C40)
94
70
78
79
83
90
90
91
93
92
91
91
89
92
92
90
89
89
87
90
65
73
73
75
84
86
88
90
89
88
89
86
89
89
86
85
84
82
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
4
7
7
8
10
7
5
3
3
3
3
2
3
3
3
5
5
6
6
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
ParameterLCS
%RecoveryLCSD
%Recovery%Recovery
Limits RPD RPD Limits
NJ Extractable Petroleum Hydrocarbons (Total) - Westborough Lab Associated sample(s): 05-07 Batch: WG609036-2 WG609036-3
Lab Control Sample AnalysisBatch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
05/28/13
Qual Qual Qual
Serial_No:05281316:15
Page 53 of 75
ParameterLCS
%RecoveryLCSD
%Recovery%Recovery
Limits RPD RPD Limits
NJ Extractable Petroleum Hydrocarbons (Total) - Westborough Lab Associated sample(s): 05-07 Batch: WG609036-2 WG609036-3
Lab Control Sample AnalysisBatch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
Chloro-Octadecane
o-Terphenyl
94
93
40-140
40-140
89
88
Surrogate Qual%Recovery Qual%RecoveryLCS LCSD
05/28/13
AcceptanceCriteria
Qual Qual Qual
Serial_No:05281316:15
Page 54 of 75
Total EPH
Nonane (C9)
Decane (C10)
Dodecane (C12)
Tetradecane (C14)
Hexadecane (C16)
Octadecane (C18)
Eicosane (C20)
Heneicosane (C21)
Docosane (C22)
Tetracosane (C24)
Hexacosane (C26)
Octacosane (C28)
Triacontane (C30)
Dotriacontane (C32)
Tetratriacontane (C34)
Hexatriacontane (C36)
Octatriacontane (C38)
Tetracontane (C40)
375.
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
724
3.87
4.68
5.58
8.47
8.60
8.16
7.76
7.87
7.46
7.07
6.94
6.72
6.94
6.91
6.76
6.80
6.87
6.85
129
51
62
74
112
114
108
103
104
99
94
92
89
92
92
90
90
91
91
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
ParameterNative Sample
MS Found
MS%Recovery
MSD Found
MSD %Recovery RPD
RPD Limits
NJ Extractable Petroleum Hydrocarbons (Total) - Westborough Lab Associated sample(s): 05-07 QC Batch ID: WG609036-4 QC Sample: L1308954-05 Client ID: UST-3 8-8.5
271
7.54
7.54
7.54
7.54
7.54
7.54
7.54
7.54
7.54
7.54
7.54
7.54
7.54
7.54
7.54
7.54
7.54
7.54
MS Added
Matrix Spike AnalysisBatch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
05/28/13
RecoveryLimitsQual Qual Qual
Serial_No:05281316:15
Page 55 of 75
ParameterNative Sample
MS Found
MS%Recovery
MSD Found
MSD %Recovery RPD
RPD Limits
NJ Extractable Petroleum Hydrocarbons (Total) - Westborough Lab Associated sample(s): 05-07 QC Batch ID: WG609036-4 QC Sample: L1308954-05 Client ID: UST-3 8-8.5
MS Added
Matrix Spike AnalysisBatch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
05/28/13
Chloro-Octadecane
o-Terphenyl
40-140
40-140
Surrogate % RecoveryAcceptance
CriteriaQualifier
91
92
% Recovery QualifierMS MSD
RecoveryLimitsQual Qual Qual
Serial_No:05281316:15
Page 56 of 75
Total EPH 375. 210 mg/kg 56 50
Units RPDParameter Native Sample Duplicate Sample RPD Limits
NJ Extractable Petroleum Hydrocarbons (Total) - Westborough Lab Associated sample(s): 05-07 QC Batch ID: WG609036-5 QC Sample: L1308954-05 Client ID: UST-3 8-8.5
Not Specified
12-1272
Project Name:
Project Number:
L1308954Lab Number:
Report Date:
Lab Duplicate AnalysisBatch Quality Control
Chloro-Octadecane
o-Terphenyl
82
83
40-140
40-140
Surrogate %Recovery QualifierAcceptance
Criteria
05/28/13
88
93
%Recovery Qualifier
Qual
Q
Serial_No:05281316:15
Page 57 of 75
INORGANICS&
MISCELLANEOUS
Serial_No:05281316:15
Page 58 of 75
FF
DC-1Client ID:05/16/13 10:15Date Collected:05/17/13Date Received:
Parameter ResultDilution Factor
Matrix: Soil
PEMBERTON, NJSample Location:
L1308954-01Lab ID:
Qualifier Units RL
SAMPLE RESULTS
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
Field Prep:
DateAnalyzed
AnalyticalMethod Analyst
Not Specified
General Chemistry - Westborough LabSolids, Total 88.1 % 10.100 05/20/13 09:46 30,2540G MO
Date Prepared
-
05/28/13
MDL
NA
Serial_No:05281316:15
Page 59 of 75
FF
DC-2Client ID:05/16/13 10:40Date Collected:05/17/13Date Received:
Parameter ResultDilution Factor
Matrix: Soil
PEMBERTON, NJSample Location:
L1308954-02Lab ID:
Qualifier Units RL
SAMPLE RESULTS
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
Field Prep:
DateAnalyzed
AnalyticalMethod Analyst
Not Specified
General Chemistry - Westborough LabSolids, Total 79.7 % 10.100 05/20/13 09:46 30,2540G MO
Date Prepared
-
05/28/13
MDL
NA
Serial_No:05281316:15
Page 60 of 75
FF
UST-3 8-8.5Client ID:05/16/13 11:22Date Collected:05/17/13Date Received:
Parameter ResultDilution Factor
Matrix: Soil
PEMBERTON, NJSample Location:
L1308954-05Lab ID:
Qualifier Units RL
SAMPLE RESULTS
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
Field Prep:
DateAnalyzed
AnalyticalMethod Analyst
Not Specified
General Chemistry - Westborough LabSolids, Total 85.4 % 10.100 05/20/13 09:46 30,2540G MO
Date Prepared
-
05/28/13
MDL
NA
Serial_No:05281316:15
Page 61 of 75
FF
UST-4 7.5-8Client ID:05/16/13 11:31Date Collected:05/17/13Date Received:
Parameter ResultDilution Factor
Matrix: Soil
PEMBERTON, NJSample Location:
L1308954-06Lab ID:
Qualifier Units RL
SAMPLE RESULTS
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
Field Prep:
DateAnalyzed
AnalyticalMethod Analyst
Not Specified
General Chemistry - Westborough LabSolids, Total 84.1 % 10.100 05/20/13 09:46 30,2540G MO
Date Prepared
-
05/28/13
MDL
NA
Serial_No:05281316:15
Page 62 of 75
FF
I-1Client ID:05/16/13 10:42Date Collected:05/17/13Date Received:
Parameter ResultDilution Factor
Matrix: Soil
PEMBERTON, NJSample Location:
L1308954-07Lab ID:
Qualifier Units RL
SAMPLE RESULTS
Project Name:
Project Number:
Lab Number:
Report Date:
Not Specified
12-1272
L1308954
Field Prep:
DateAnalyzed
AnalyticalMethod Analyst
Not Specified
General Chemistry - Westborough LabSolids, Total 96.0 % 10.100 05/20/13 09:46 30,2540G MO
Date Prepared
-
05/28/13
MDL
NA
Serial_No:05281316:15
Page 63 of 75
Solids, Total 83.0 83.6 % 1 20
Units RPDParameter Native Sample Duplicate Sample RPD Limits
General Chemistry - Westborough Lab Associated sample(s): 01-02,05-07 QC Batch ID: WG609228-1 QC Sample: L1308924-01 Client ID: DUP Sample
Not Specified
12-1272
Project Name:
Project Number:
L1308954Lab Number:
Report Date:
Lab Duplicate AnalysisBatch Quality Control
05/28/13
Qual
Serial_No:05281316:15
Page 64 of 75
*Values in parentheses indicate holding time in days
L1308954-01A
L1308954-01B
L1308954-01C
L1308954-01D
L1308954-01E
L1308954-01F
L1308954-01G
L1308954-02A
L1308954-02B
L1308954-02C
L1308954-02D
L1308954-02E
L1308954-02F
L1308954-02G
L1308954-03A
L1308954-04A
L1308954-05A
L1308954-06A
L1308954-07A
L1308954-08A
L1308954-08B
L1308954-08C
L1308954-08D
L1308954-08E
L1308954-08F
L1308954-09A
L1308954-09B
5 gram Encore Sampler
5 gram Encore Sampler
5 gram Encore Sampler
Vial MeOH preserved split
Vial Water preserved split
Vial Water preserved split
Plastic 2oz unpreserved for TS
5 gram Encore Sampler
5 gram Encore Sampler
5 gram Encore Sampler
Vial MeOH preserved split
Vial Water preserved split
Vial Water preserved split
Plastic 2oz unpreserved for TS
Amber 250ml unpreserved
Amber 250ml unpreserved
Amber 250ml unpreserved
Amber 250ml unpreserved
Amber 250ml unpreserved
Vial HCl preserved
Vial HCl preserved
Vial HCl preserved
Vial Na2S2O3 preserved
Vial Na2S2O3 preserved
Vial Na2S2O3 preserved
Vial HCl preserved
Vial HCl preserved
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Absent
Absent
Absent
Absent
Absent
Absent
Absent
Absent
Absent
Absent
Absent
Absent
Absent
Absent
Absent
Absent
Absent
Absent
Absent
Absent
Absent
Absent
Absent
Absent
Absent
Absent
Absent
A AbsentCooler
Custody SealCooler Information
Not Specified
12-1272
NJ-8260HLW(2)
NJ-8260HLW(2)
NJ-8260HLW(2)
NJ-8260HLW(14)
NJ-8260HLW(14)
NJ-8260HLW(14)
TS(7)
NJ-8260HLW(2)
NJ-8260HLW(2)
NJ-8260HLW(2)
NJ-8260HLW(14)
NJ-8260HLW(14)
NJ-8260HLW(14)
TS(7)
HOLD()
HOLD()
NJEPH-TPH-CAT1(14),TS(7)
NJEPH-TPH-CAT1(14),TS(7)
NJEPH-TPH-CAT1(14),TS(7)
8260-SIM(14),NJ-8260(14)
8260-SIM(14),NJ-8260(14)
8260-SIM(14),NJ-8260(14)
8011(14)
8011(14)
8011(14)
8260-SIM(14),NJ-8260(14)
8260-SIM(14),NJ-8260(14)
Project Name:
Project Number:
L1308954Lab Number:
Report Date:
Sample Receipt and Container Information
Container ID Container Type Cooler pHTempdeg C Pres Seal
Container Information
Analysis(*)
05/28/13
Were project specific reporting limits specified? YES
Reagent H2O Preserved Vials Frozen on: 05/18/2013 01:01
Serial_No:05281316:15
Page 65 of 75
*Values in parentheses indicate holding time in days
L1308954-09C
L1308954-09D
L1308954-09E
L1308954-09F
L1308954-10A
L1308954-11A
Vial HCl preserved
Vial Na2S2O3 preserved
Vial Na2S2O3 preserved
Vial Na2S2O3 preserved
Amber 250ml unpreserved
Amber 250ml unpreserved
A
A
A
A
A
A
N/A
N/A
N/A
N/A
N/A
N/A
2.7
2.7
2.7
2.7
2.7
2.7
Y
Y
Y
Y
Y
Y
Absent
Absent
Absent
Absent
Absent
Absent
Not Specified
12-1272
8260-SIM(14),NJ-8260(14)
8011(14)
8011(14)
8011(14)
HOLD()
HOLD()
Project Name:
Project Number:
L1308954Lab Number:
Report Date:
Container ID Container Type Cooler pHTempdeg C Pres Seal
Container Information
Analysis(*)
05/28/13
Serial_No:05281316:15
Page 66 of 75
Report Format: DU Report with "J" Qualifiers
GLOSSARY
Project Name:
Project Number:
Lab Number:
Report Date:
L1308954Not Specified
12-1272 05/28/13
Acronyms
EDL
EPA
LCS
LCSD
LFB
MDL
MS
MSD
NA
NC
NI
RL
RPD
SRM
Estimated Detection Limit: This value represents the level to which target analyte concentrations are reported as estimated values, when those target analyte concentrations are quantified below the reporting limit (RL). The EDL includes any adjustments from dilutions, concentrations or moisture content, where applicable. The use of EDLs is specific to the analysis of PAHs using Solid-Phase Microextraction (SPME).Environmental Protection Agency.
Laboratory Control Sample: A sample matrix, free from the analytes of interest, spiked with verified known amounts of analytes or a material containing known and verified amounts of analytes.Laboratory Control Sample Duplicate: Refer to LCS.
Laboratory Fortified Blank: A sample matrix, free from the analytes of interest, spiked with verified known amounts of analytes or a material containing known and verified amounts of analytes.Method Detection Limit: This value represents the level to which target analyte concentrations are reported as estimated values, when those target analyte concentrations are quantified below the reporting limit (RL). The MDL includes any adjustments from dilutions, concentrations or moisture content, where applicable.Matrix Spike Sample: A sample prepared by adding a known mass of target analyte to a specified amount of matrix sample for which an independent estimate of target analyte concentration is available. Matrix Spike Sample Duplicate: Refer to MS.
Not Applicable.
Not Calculated: Term is utilized when one or more of the results utilized in the calculation are non-detect at the parameter's reporting unit.Not Ignitable.
Reporting Limit: The value at which an instrument can accurately measure an analyte at a specific concentration. The RL includes any adjustments from dilutions, concentrations or moisture content, where applicable.Relative Percent Difference: The results from matrix and/or matrix spike duplicates are primarily designed to assess the precisionof analytical results in a given matrix and are expressed as relative percent difference (RPD). Values which are less than five times the reporting limit for any individual parameter are evaluated by utilizing the absolute difference between the values; although the RPD value will be provided in the report.Standard Reference Material: A reference sample of a known or certified value that is of the same or similar matrix as the associated field samples.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Terms
Analytical Method: Both the document from which the method originates and the analytical reference method. (Example: EPA 8260B is shown as 1,8260B.) The codes for the reference method documents are provided in the References section of the Addendum.
Data Qualifiers
A
B
C
D
E
G
H
I
-
-
-
-
-
-
-
-
Spectra identified as "Aldol Condensation Product".
The analyte was detected above the reporting limit in the associated method blank. Flag only applies to associated field samples that have detectable concentrations of the analyte at less than five times (5x) the concentration found in the blank. For MCP-related projects, flag only applies to associated field samples that have detectable concentrations of the analyte at less than ten times (10x) the concentration found in the blank. For DOD-related projects, flag only applies to associated field samples that have detectable concentrations of the analyte at less than ten times (10x) the concentration found in the blank AND the analyte was detected above one-half the reporting limit (or above the reporting limit for common lab contaminants) in the associated method blank. For NJ-Air-related projects, flag only applies to associated field samples that have detectable concentrations of the analyte above the reporting limit.Co-elution: The target analyte co-elutes with a known lab standard (i.e. surrogate, internal standards, etc.) for co-extracted analyses.Concentration of analyte was quantified from diluted analysis. Flag only applies to field samples that have detectable concentrations of the analyte.Concentration of analyte exceeds the range of the calibration curve and/or linear range of the instrument.
The concentration may be biased high due to matrix interferences (i.e, co-elution) with non-target compound(s). The result should be considered estimated.The analysis of pH was performed beyond the regulatory-required holding time of 15 minutes from the time of sample collection.
The RPD between the results for the two columns exceeds the method-specified criteria; however, the lower value has been reported
1 The reference for this analyte should be considered modified since this analyte is absent from the target analyte list of the originalmethod.
-
Footnotes
Serial_No:05281316:15
Page 67 of 75
Report Format: DU Report with "J" Qualifiers
Project Name:
Project Number:
Lab Number:
Report Date:
L1308954Not Specified
12-1272 05/28/13
Data Qualifiers
M
NJ
P
Q
R
RE
-
-
-
-
-
-
due to obvious interference.
Reporting Limit (RL) exceeds the MCP CAM Reporting Limit for this analyte.
Presumptive evidence of compound. This represents an estimated concentration for Tentatively Identified Compounds (TICs), where the identification is based on a mass spectral library search.The RPD between the results for the two columns exceeds the method-specified criteria.
The quality control sample exceeds the associated acceptance criteria. For DOD-related projects, LCS and/or Continuing CalibrationStandard exceedences are also qualified on all associated sample results. Note: This flag is not applicable for matrix spike recoverieswhen the sample concentration is greater than 4x the spike added or for batch duplicate RPD when the sample concentrations are lessthan 5x the RL. (Metals only.)Analytical results are from sample re-analysis.
Analytical results are from sample re-extraction.
J
ND
-
-
Estimated value. The Target analyte concentration is below the quantitation limit (RL), but above the Method Detection Limit (MDL) or Estimated Detection Limit (EDL) for SPME-related analyses. This represents an estimated concentration for Tentatively Identified Compounds (TICs).Not detected at the method detection limit (MDL) for the sample, or estimated detection limit (EDL) for SPME-related analyses.
Serial_No:05281316:15
Page 68 of 75
Alpha Analytical performs services with reasonable care and diligence normal to the analytical testinglaboratory industry. In the event of an error, the sole and exclusive responsibility of Alpha Analyticalshall be to re-perform the work at it's own expense. In no event shall Alpha Analytical be held liablefor any incidental, consequential or special damages, including but not limited to, damages in any wayconnected with the use of, interpretation of, information or analysis provided by Alpha Analytical.
We strongly urge our clients to comply with EPA protocol regarding sample volume, preservation, cooling,containers, sampling procedures, holding time and splitting of samples in the field.
LIMITATION OF LIABILITIES
1
30
103
Test Methods for Evaluating Solid Waste: Physical/Chemical Methods. EPA SW-846. Third Edition. Updates I - IIIA, 1997.
Standard Methods for the Examination of Water and Wastewater. APHA-AWWA-WPCF. 18th Edition. 1992.
Analysis of Extractable Petroleum Hydrocarbon Compounds (EPH) in Aqueous and Soil/Sediment/Sludge Matrices. New Jersey Department of Environmental Protection, Site Remediation Program, (Version 1.1), Document # NJDEP EPH 10/08, Revision 3, August 2010.
Project Name:
Project Number:
Lab Number:
Report Date:
L1308954Not Specified
12-1272
REFERENCES
05/28/13
Serial_No:05281316:15
Page 69 of 75
Certificate/Approval Program Summary Last revised December 19, 2012 - Westboro Facility
The following list includes only those analytes/methods for which certification/approval is currently held.
For a complete listing of analytes for the referenced methods, please contact your Alpha Customer Service Representative.
Connecticut Department of Public Health Certificate/Lab ID: PH-0574. NELAP Accredited Solid Waste/Soil. Drinking Water (Inorganic Parameters: Color, pH, Turbidity, Conductivity, Alkalinity, Chloride, Free Residual Chlorine, Fluoride, Calcium Hardness, Sulfate, Nitrate, Nitrite, Aluminum, Antimony, Arsenic, Barium, Beryllium, Cadmium, Calcium, Chromium, Copper, Iron, Lead, Magnesium, Manganese, Mercury, Nickel, Selenium, Silver, Sodium, Thallium, Zinc, Total Dissolved Solids, Total Organic Carbon, Total Cyanide, Perchlorate. Organic Parameters: Volatile Organics 524.2, Total Trihalomethanes 524.2, 1,2-Dibromo-3-chloropropane (DBCP) 504.1, Ethylene Dibromide (EDB) 504.1, 1,4-Dioxane (Mod 8270). Microbiology Parameters: Total Coliform-MF mEndo (SM9222B), Total Coliform – Colilert (SM9223, Enumeration and P/A), E. Coli. – Colilert (SM9223, Enumeration and P/A), HPC – Pour Plate (SM9215B), Fecal Coliform – MF m-FC (SM9222D), Fecal Coliform-EC Medium (SM 9221E). Wastewater/Non-Potable Water (Inorganic Parameters: Color, pH, Conductivity, Acidity, Alkalinity, Chloride, Total Residual Chlorine, Fluoride, Total Hardness, Silica, Sulfate, Sulfide, Ammonia, Kjeldahl Nitrogen, Nitrate, Nitrite, O-Phosphate, Total Phosphorus, Aluminum, Antimony, Arsenic, Barium, Beryllium, Boron, Cadmium, Calcium, Chromium, Hexavalent Chromium, Cobalt, Copper, Iron, Lead, Magnesium, Manganese, Mercury, Molybdenum, Nickel, Potassium, Selenium, Silver, Sodium, Strontium, Thallium, Tin, Titanium, Vanadium, Zinc, Total Residue (Solids), Total Dissolved Solids, Total Suspended Solids (non-filterable), BOD, CBOD, COD, TOC, Total Cyanide, Phenolics, Foaming Agents (MBAS), Bromide, Oil and Grease. Organic Parameters: PCBs, Organochlorine Pesticides, Technical Chlordane, Toxaphene, Acid Extractables (Phenols), Benzidines, Phthalate Esters, Nitrosamines, Nitroaromatics & Isophorone, Polynuclear Aromatic Hydrocarbons, Haloethers, Chlorinated Hydrocarbons, Volatile Organics, TPH (HEM/SGT), CT- Extractable Petroleum Hydrocarbons (ETPH), MA-EPH, MA-VPH. Microbiology Parameters: Total Coliform – MF mEndo (SM9222B), Total Coliform – MTF (SM9221B), E. Coli – Colilert (SM9223 Enumeration), HPC – Pour Plate (SM9215B), Fecal Coliform – MF m-FC (SM9222D), Fecal Coliform – A-1 Broth (SM9221E), Enterococcus - Enterolert. Solid Waste/Soil (Inorganic Parameters: pH, Sulfide, Aluminum, Antimony, Arsenic, Barium, Beryllium, Boron, Cadmium, Calcium, Chromium, Hexavalent Chromium, Cobalt, Copper, Iron, Lead, Magnesium, Manganese, Mercury, Molybdenum, Nickel, Potassium, Selenium, Silver, Sodium, Thallium, Tin, Vanadium, Zinc, Total Cyanide, Ignitability, Phenolics, Corrosivity, TCLP Leach (1311), SPLP Leach (1312 metals only), Reactivity. Organic Parameters: PCBs, PCBs in Oil, Organochlorine Pesticides, Technical Chlordane, Toxaphene, CT-Extractable Petroleum Hydrocarbons (ETPH), MA-EPH, MA-VPH, Dicamba, 2,4-D, 2,4,5-T, 2,4,5-TP(Silvex), Dalapon, Volatile Organics (SW 8260), Acid Extractables (Phenols) (SW 8270), Benzidines (SW 8270), Phthalates (SW 8270), Nitrosamines (SW 8270), Nitroaromatics & Cyclic Ketones (SW 8270), PAHs (SW 8270), Haloethers (SW 8270), Chlorinated Hydrocarbons (SW 8270). ) Maine Department of Human Services Certificate/Lab ID: 2009024. Drinking Water (Inorganic Parameters: SM9215B, 9222D, 9223B, EPA 180.1, 353.2, SM2130B, 2320B, 2540C, 4500Cl-D, 4500CN-C, 4500CN-E, 4500F-C, 4500H+B, 4500NO3-F, EPA 200.7, EPA 200.8, 245.1, EPA 300.0. Organic Parameters: 504.1, 524.2.) Wastewater/Non-Potable Water (Inorganic Parameters: EPA 120.1, 1664A, 350.1, 351.1, 353.2, 410.4, 420.1, SM2320B, 2510B, 2540C, 2540D, 426C, 4500Cl-D, 4500Cl-E, 4500CN-C, 4500CN-E, 4500F-B, 4500F-C, 4500H+B, 4500Norg-B, 4500Norg-C, 4500NH3-B, 4500NH3-G, 4500NO3-F, 4500P-B, 4500P-E, 5210B, 5220D, 5310C, 9010B, 9040B, 9030B, 7470A, 7196A, 2340B, EPA 200.7, 6010B, 6010C, 200.8, 6020, 245.1, 1311, 1312, 3005A, Enterolert, 9223B, 9222D. Organic Parameters: 608, 624, 625, 8081A, 8081B, 8082, 8082A, 8330, 8151A, 8260B, 8260C, 8270C, 8270D, 3510C, 3630C, 5030B, ME-DRO, ME-GRO, MA-EPH, MA-VPH.) Solid Waste/Soil (Inorganic Parameters: 9010B, 9012A, 9014, 9030B, 9040B, 9045C, 6010B, 6010C, 6020, 6020A, 7471A, 7471B, 7196A, 9050A, 1010, 1030, 9065, 1311, 1312, 3005A, 3050B. Organic Parameters: ME-DRO, ME-GRO, MA-EPH, MA-VPH, 8260B, 8270C, 8270D, 8330, 8151A, 8081A, 8081B, 8082, 8082A, 3540C, 3546, 3580A, 3630C, 5030B, 5035.) Massachusetts Department of Environmental Protection Certificate/Lab ID: M-MA086. Drinking Water (Inorganic Parameters: (EPA 200.8 for: Sb,As,Ba,Be,Cd,Cr,Cu,Pb,Ni,Se,Tl) (EPA 200.7 for: Ba,Be,Ca,Cd,Cr,Cu,Na,Ni) 245.1, (300.0 for: Nitrate-N, Fluoride, Sulfate); (EPA 353.2 for: Nitrate-N, Nitrite-N); (SM4500NO3-F for: Nitrate-N and Nitrite-N); 4500F-C, 4500CN-CE, EPA 180.1, SM2130B, SM4500Cl-D, 2320B, SM2540C, SM4500H-B. Organic Parameters: (EPA 524.2 for: Trihalomethanes, Volatile Organics); (504.1 for: 1,2-Dibromoethane, 1,2-Dibromo-3-Chloropropane), EPA 332. Microbiology Parameters: SM9215B; ENZ. SUB. SM9223; ColilertQT SM9223B; MF-SM9222D.)
Serial_No:05281316:15
Page 70 of 75
Non-Potable Water (Inorganic Parameters:, (EPA 200.8 for: Al,Sb,As,Be,Cd,Cr,Cu,Pb,Mn,Ni,Se,Ag,Tl,Zn); (EPA 200.7 for: Al,Sb,As,Be,Cd,Ca,Cr,Co,Cu,Fe,Pb,Mg,Mn,Mo,Ni,K,Se,Ag,Na,Sr,Ti,Tl,V,Zn); 245.1, SM4500H,B, EPA 120.1, SM2510B, 2540C, 2340B, 2320B, 4500CL-E, 4500F-BC, 426C, SM4500NH3-BH, (EPA 350.1 for: Ammonia-N), LACHAT 10-107-06-1-B for Ammonia-N, SM4500NO3-F, 353.2 for Nitrate-N, SM4500NH3-BC-NES, EPA 351.1, SM4500P-E, 4500P-B,E, 5220D, EPA 410.4, SM 5210B, 5310C, 4500CL-D, EPA 1664, SM14 510AC, EPA 420.1, SM4500-CN-CE, SM2540D. Organic Parameters: (EPA 624 for Volatile Halocarbons, Volatile Aromatics),(608 for: Chlordane, Toxaphene, Aldrin, alpha-BHC, beta-BHC, gamma-BHC, delta-BHC, Dieldrin, DDD, DDE, DDT,Endosulfan I, Endosulfan II, Endosulfan sulfate, Endrin, Endrin Aldehyde, Heptachlor, Heptachlor Epoxide, PCBs-Water), (EPA 625 for SVOC Acid Extractables and SVOC Base/Neutral Extractables), 600/4-81-045-PCB-Oil. Microbiology Parameters: (ColilertQT SM9223B; Enterolert-QT: SM9222D-MF.) New Hampshire Department of Environmental Services Certificate/Lab ID: 200307. NELAP Accredited. Drinking Water (Inorganic Parameters: SM 9222B, 9223B, 9215B, EPA 200.7, 200.8, 300.0, SM4500CN-E, 4500H+B, 4500NO3-F, 2320B, 2510B, 2540C, 4500F-C, 5310C, 2120B, EPA 332.0. Organic Parameters: 504.1, 524.2.) Non-Potable Water (Inorganic Parameters: SM9222D, 9221B, 9222B, 9221E-EC, EPA 3005A, 200.7, 200.8, 245.1, SW-846 6010C, 6020A, 7196A, 7470A, SM3500-CR-D, EPA 120.1, 300.0, 350.1, 350.2, 351.1, 353.2, 410.4, 420.1, 426C, 1664A, SW-846 9010B, 9010C, 9030, 9040B, 9040C, SM2120B, 2310B, 2320B, 2340B, 2540B, 2540D, 4500H+B, 4500CL-E, 4500CN-E, 4500NH3-H, 4500NO3-F, 4500NO2-B, 4500P-E, 4500-S2-D, 4500SO3-B, 5210B, 5220D, 2510B, 2540C, 4500F-C, 5310C, 5540C, LACHAT 10-204-00-1-A, LACHAT 10-107-06-2-D, 3060A. Organic Parameters: SW-846 3510C, 3630C, 5030B, 8260C, 8270D, 8330, EPA 624, 625, 608, SW-846 8082A, 8081B, 8015C, 8151A, 8330, 8270D-SIM.) Solid & Chemical Materials (Inorganic Parameters: SW-846 6010C, 6020A, 7196A, 7471B, 1010, 1010A, 1030, 9010C, 9012B, 9014, 9030B, 9040C, 9045C, 9045D, 9050, 9065, 9251, 1311, 1312, 3005A, 3050B, 3060A. Organic Parameters: SW-846 3540C, 3546, 3050B, 3580A, 3620D, 3630C, 5030B, 5035, 8260C, 8270D, 8270D-SIM, 8330, 8151A, 8015B, 8015C, 8082A, 8081B.) New Jersey Department of Environmental Protection Certificate/Lab ID: MA935. NELAP Accredited. Drinking Water (Inorganic Parameters: SM9222B, 9221E, 9223B, 9215B, 4500CN-CE, 4500NO3-F, 4500F-C, EPA 300.0, 200.7, 200.8, 245.1, 2540C, SM2120B, 2320B, 2510B, 5310C, SM4500H-B. Organic Parameters: EPA 332, 504.1, 524.2.) Non-Potable Water (Inorganic Parameters: SM5210B, EPA 410.4, SM5220D, 4500Cl-E, EPA 300.0, SM2120B, 2340B, SM4500F-BC, EPA 200.7, 200.8, 351.1, LACHAT 10-107-06-2-D, EPA 353.2, SM4500NO3-F, 4500NO2-B, EPA 1664A, SM5310B, C or D, 4500-PE, EPA 420.1, SM510ABC, SM4500P-B5+E, 2540B, 2540C, 2540D, EPA 120.1, SM2510B, SM2520B, SM15 426C, 9222D, 9221B, 9221C, 9221E, 9222B, 9215B, 2310B, 2320B, 4500NH3-H, 4500-S D, EPA 350.1, 350.2, SW-846 1312, 7470A, 5540C, SM4500H-B, 4500SO3-B, SM3500Cr-D, 4500CN-CE, EPA 245.1, SW-846 9040B, 9040C, 3005A, 3015, EPA 6010B, 6010C, 6020, 6020A, 7196A, 3060A, SW-846 9010C, 9030B. Organic Parameters: SW-846 8260B, 8260C, 8270C, 8270D, 8270C-SIM, 8270D-SIM, 3510C, EPA 608, 624, 625, SW-846 3630C, 5030B, 8011, 8015C, 8081A, 8081B, 8082, 8082A, 8151A, 8330, 1,4-Dioxane by NJ Modified 8270, 8015B, NJ EPH.) Solid & Chemical Materials (Inorganic Parameters: SW-846, 6010B, 6010C, 6020, 6020A, 7196A, 3060A, 9030B, 1010, 1010A, 1030, 1311, 1312, 3005A, 3050B, 7471A, 7471B, 9010C, 9012B, 9014, 9038, 9040B, 9040C, 9045C, 9045D, 9050A, 9065, 9251. Organic Parameters: SW-846 8015B, 8015C, 8081A, 8081B, 8082, 8082A, 8151A, 8330, 8260B, 8260C, 8270C, 8270D, 8270C-SIM, 8270D-SIM, 3540C, 3546, 3580A, 3620C, 3630C, 5030B, 5035L, 5035H, NJ EPH.) New York Department of Health Certificate/Lab ID: 11148. NELAP Accredited. Drinking Water (Inorganic Parameters: SM9223B, 9222B, 9215B, EPA 200.8, 200.7, 245.2, SM5310C, EPA 332.0, SM2320B, EPA 300.0, SM2120B, 4500CN-E, 4500F-C, 4500NO3-F, 2540C, SM 2510B. Organic Parameters: EPA 524.2, 504.1.) Non-Potable Water (Inorganic Parameters: SM9221E, 9222D, 9221B, 9222B, 9215B, 5210B, 5310C, EPA 410.4, SM5220D, 2310B-4a, 2320B, EPA 200.7, 300.0, SM4500CL-E, 4500F-C, SM15 426C, EPA 350.1, SM4500NH3-BH, EPA 351.1, LACHAT 10-107-06-2, EPA 353.2, SM4500-NO3-F, 4500-NO2-B, 4500P-E, 2540C, 2540B, 2540D, EPA 200.8, EPA 6010B, 6010C, 6020, 6020A, EPA 7196A, SM3500Cr-D, EPA 245.1, 7470A, SM2120B, LACHAT 10-204-00-1-A, 4500CN-CE, EPA 1664A, EPA 420.1, SM14 510C, EPA 120.1, SM2510B, SM4500S-D, SM5540C, EPA 3005A, 3015, 9010C, 9030B. Organic Parameters: EPA 624, 8260B, 8260C, 8270C, 8270D, 8270C-SIM, 8270D-SIM, 625, 608, 8081A, 8081B, 8151A, 8330, 8082, 8082A, EPA 3510C, 5030B.) Solid & Hazardous Waste (Inorganic Parameters: EPA 1010A, 1030, EPA 6010B, 6010C, 7196A, 7471A, 7471B, 9012B, 9014, 9065, 9050A, EPA 1311, 1312, 3005A, 3050B, 9010C, 9030B, 9040C, 9045D. Organic Parameters: EPA 8260B, 8260C, 8270C, 8270D, 8270C-SIM, 8270D-SIM, 8015B, 8015C, 8081A, 8081B, 8151A, 8330, 8082 8082A, 3540C,
Serial_No:05281316:15
Page 71 of 75
3546, 3580A, 5030B, 5035A-H, 5035A-L.) North Carolina Department of the Environment and Natural Resources Certificate/Lab ID : 666. (Inorganic Parameters: SM2310B, 2320B, 4500Cl-E, 4500Cn-E, 9014, Lachat 10-204-00-1-X, 1010A, 1030, 4500NO3-F, 353.2, 4500P-E, 4500SO4-E, 300.0, 4500S-D, 5310B, 5310C, 6010C, 6020A, 200.7, 200.8, 3500Cr-B, 7196A, 245.1, 7470A, 7471B, 1311,1312. Organic Parameters: 608, 8081B, 8082A, 624, 8260B, 625, 8270D, 8151A, 8015C, 504.1, MA-EPH, MA-VPH.) Drinking Water Program Certificate/Lab ID: 25700. (Inorganic Parameters: Chloride EPA 300.0. Organic Parameters: 524.2) Pennsylvania Department of Environmental Protection Certificate/Lab ID : 68-03671. NELAP Accredited. Drinking Water (Inorganic Parameters: 200.7, 200.8, 300.0, 332.0, 2120B, 2320B, 2510B, 2540C, 4500-CN-CE, 4500F-C, 4500H+-B, 4500NO3-F, 5310C. Organic Parameters: EPA 524.2, 504.1) Non-Potable Water (Inorganic Parameters: EPA 120.1, 1312, 3005A,3015, 3060A, 200.7, 200.8, 410.4, 1664A, SM2540D, 5210B, 5220D, 4500-P,BE, 245.1, 300.0, 350.1, 350.2, 351.1, 353.2, 420.1, 6010C, 6020A, 7196A, 7470A, 9030B, 2120B, 2310B, 2320B, 2510B, 2540B, 2540C, 3500Cr-D, 426C, 4500CN-CE, 4500Cl-E, 4500F-B, 4500F-C, 4500H+-B, 4500NH3-H, 4500NO2-B, 4500NO3-F, 4500S-D, 4500SO3-B, 5310BCD, 5540C, 9010C, 9040C. Organic Parameters: EPA 3510C, 3630C, 5030B, 625, 624, 608, 8081B, 8082A, 8151A, 8260C, 8270D, 8270D-SIM, 8330, 8015C, NJ-EPH.) Solid & Hazardous Waste (Inorganic Parameters: EPA 350.1, 1010, 1030, 1311, 1312, 3005A, 3050B, 3060A, 6010C, 6020A, 7196A, 7471B, 9010C, 9012B, 9014, 9040B, 9045D, 9050A, 9065, SM 4500NH3-BH, 9030B, 9038, 9251. Organic Parameters: 3540C, 3546, 3580A, 3620C, 3630C, 5035, 8015C, 8081B, 8082A, 8151A, 8260C, 8270D, 8270D-SIM, 8330, NJ-EPH.) Rhode Island Department of Health Certificate/Lab ID: LAO00065. NELAP Accredited via NJ-DEP. Refer to MA-DEP Certificate for Potable and Non-Potable Water. Refer to NJ-DEP Certificate for Potable and Non-Potable Water. Texas Commisson on Environmental Quality Certificate/Lab ID: T104704476. NELAP Accredited. Non-Potable Water (Inorganic Parameters: EPA 120.1, 1664, 200.7, 200.8, 245.1, 245.2, 300.0, 350.1, 351.1, 353.2, 410.4, 420.1, 6010, 6020, 7196, 7470, 9040, SM 2120B, 2310B, 2320B, 2510B, 2540B, 2540C, 2540D, 426C, 4500CL-E, 4500CN-E, 4500F-C, 4500H+B, 4500NH3-H, 4500NO2B, 4500P-E, 4500 S2¯D, 510C, 5210B, 5220D, 5310C, 5540C. Organic Parameters: EPA 608, 624, 625, 8081, 8082, 8151, 8260, 8270, 8330.) Solid & Hazardous Waste (Inorganic Parameters: EPA 1311, 1312, 9012, 9014, 9040, 9045, 9050, 9065.) Virginia Division of Consolidated Laboratory Services Certificate/Lab ID: 460195. NELAP Accredited. Drinking Water (Inorganic Parameters: EPA 200.7, 200.8, 300.0, 2510B, 2120B, 2540C, 4500CN-CE, 245.2, 2320B, 4500F-C, 4500NO3-F, 5310C. Organic Parameters: EPA 504.1, 524.2.) Non-Potable Water (Inorganic Parameters: EPA 120.1, 1664A, 200.7, 200.8, 245.1, 300.0, 3005A, 3015, 1312, 6010B, 6010C, 3060A, 353.2, 420.1, 6020, 6020A, SM4500S-D, SM4500-CN-CE, Lachat 10-204-00-1-X, 7196A, 7470A, 9010B, 9040B, 2310B, 2320B, 2510B, 2540B, 2540C, 3500Cr-D, 426C, 4500Cl-E, 4500F-B, 4500F-C, 4500PE, 510AC, 5210B, 5310B 5310C, 5540C. Organic Parameters: EPA 3510C, 3630C, 5030B, 8260B, 608, 624, 625, 8081A, 8081B, 8082, 8082A, 8151A, 8270C, 8270D, 8270C-SIM, 8270D-SIM, 8330, ) Solid & Hazardous Waste (Inorganic Parameters: EPA 1010A, 1030, 3060A, 3050B, 1311, 1312, 6010B, 6010C, 6020, , 7196A, 7471A, 7471B, 6020A, 9030B, 9010B, 9012A, 9014 9040B, 9045C, 9050A, 9065. Organic Parameters: EPA 5030B, 5035, 3540C, 3546, 355B0, 3580A, 3630C, 6020A, 8260B, 8015B, 8015C, 8081A, 8081B, 8082, 8082A, 8151A, 8270C, 8270D, 8270C-SIM, 8270D-SIM, 8330.) Department of Defense, L-A-B Certificate/Lab ID: L2217. Drinking Water (Inorganic Parameters: SM 4500H-B. Organic Parameters: EPA 524.2, 504.1.) Non-Potable Water (Inorganic Parameters: EPA 200.7, 200.8, 6010B, 6010C, 6020, 6020A, 245.1, 245.2, 7470A, 9040B, 9010B, 180.1. 300.0, 332.0, 6860, 353.2, 410.4, 9060, 1664A, SM 4500CN-E, 4500H-B, 4500NO3-F, 4500CL-D, 5220D, 5310C, 2130B, 2320B, 2540C, 3005A, 3015, 9010B, 9056, 7196A, 3500-Cr-D. Organic Parameters: EPA 8260B, 8260C, 8270C, 8270D, 8270C-SIM, 8270D-SIM, 8330A, 8082, 8082A, 8081A, 8081B, 3510C, 5030B, MassDEP EPH, MassDEP VPH.) Solid & Hazardous Waste (Inorganic Parameters: EPA 200.7, 6010B, 6010C, 7471A, 6860, 1311, 1312, 3050B, 7196A, 9010B, 9012A, 9040B, 9045C, 3500-CR-D, 4500CN-CE, 2540G, Organic Parameters: EPA 8260B, 8260C, 8270C,
Serial_No:05281316:15
Page 72 of 75
8270D, 8270C-SIM, 8270D-SIM, 8330A/B-prep, 8082, 8082A, 8081A, 8081B, 3540C, 3546, 3580A, 5035A, MassDEP EPH, MassDEP VPH.) The following analytes are not included in our current NELAP/TNI Scope of Accreditation: EPA 8260B: Freon-113, 1,2,4,5-Tetramethylbenzene, 4-Ethyltoluene. EPA 8330A: PETN, Picric Acid, Nitroglycerine, 2,6-DANT, 2,4-DANT. EPA 8270C: Methyl naphthalene, Dimethyl naphthalene, Total Methylnapthalenes, Total Dimethylnaphthalenes, 1,4-Diphenylhydrazine (Azobenzene). EPA 625: 4-Chloroaniline, 4-Methylphenol. Total Phosphorus in a soil matrix, Chloride in a soil matrix, TKN in a soil matrix, NO2 in a soil matrix, NO3 in a soil matrix. EPA 9071: Total Petroleum Hydrocarbons, Oil & Grease.
Serial_No:05281316:15
Page 73 of 75
Serial_No:05281316:15
Page 74 of 75
Serial_No:05281316:15
Page 75 of 75