tuffkote protective coatings
DESCRIPTION
tecnicaTRANSCRIPT
-
Method of Application:
By stiff bristle- brush/Plural feed airless spray gun
Pot life: 1/2 to 1 hours.
Thinner: Thinner 6756
Product Information
Limitations Uses
Application Details
The finish tends to chalk when exposed to sunlight although protective properties of the film remain practically unaffected.
Steel Surfaces:Degrease and blast clean to Sa 2 grade minimum of Swedish specification SIS - 05 -5900 - 1967.
Concrete SurfacesFor new concrete surface: Ensure that the surface is cured for minimum 2 months. Remove laitence, loose surface powder by light sand blasting. If blast cleaning is not feasible, roughen the surface by acid etching with 10% Hydrochloric Acid solution followed by thorough freshwater hosing to remove any residual acid. The surface should be perfectly dry and clean before applying Epigard solventless epoxy.
For old concrete surface: For old concrete surface: Remove grease, oil etc by solvent wiping. Remove water-soluble contaminants by fresh water hosing. Roughen the surface by acid etching, if light sand blasting is not feasible. The surface should be perfectly dry and clean before applying Epigard solventless epoxy.
Surface Preparation
1
EPIGARD SOLVENTLESSEPOXY COATING
PROTECTIVE COATINGS
DATA SHEET NO. 2006-025
Steel Surfaces:
of Swedish specification SIS - 05 -5900 - 1967.
Concrete Surfaces
cured for minimum 2 months. Remove laitence, loose surface powder by light sand blasting. If blast cleaning is not feasible, roughen the surface by acid etching with 10% Hydrochloric Acid solution followed by thorough freshwater hosing to remove any residual acid. The surface should be perfectly dry and clean before applying Epigard solventless epoxy.
For old concrete surface:
solvent wiping. Remove water-soluble contaminants by fresh water hosing. Roughen the surface by acid etching, if light sand blasting is not feasible. The surface should be perfectly dry and clean before applying Epigard solventless epoxy.
Colour
Finish
Mixing Ratio
Recommendeddry film thickness
TheoreticalSpreading Rate
Interval beforeOvercoating
In case the stipulated over coating period is over, for application of subsequent coat of paint the surface should be sweep blasted for better intercoat adhesion.
Drying time
Storage life
Dry Heat Resistance
Selected Range
Semi Glossy
Base : Accelerator3 : 2 (by weight/volume)
Minimum - 16 hoursMaximum - 48 hours
200 - 400 microns per coat
5 2.5 Sq. metre per litre
Upto 100o C (Intermittent)
Surface dry 5 - 8 hours.Handleable 18 - 24 hoursFull curing - 7 days
Upto 9 months so long as thematerial is stored in sealedcontainers under standardwarehouse storage conditions.
A two pack solvent free high performance high build epoxy coating specially designed for application as an internal coating of both steel and concrete tanks for storage of both sweet and sour crude oils,unleaded petrol, MTBE, ATF,selected range of aliphatic and aromatic hydrocarbon solvents and water. This product is suitable for safe storage of potable water also. It gives a very tough wear resistant, impervious coating to withstand many chemicals, fats and oils.
Interior tank lining,Urea Prilling Tower Internal, Floor Coating, Cooling tower, Effluent treatment plant etc.
-
DATA SHEET NO. 2006-025EPIGARD SOLVENTLESS EPOXY COATING
DISCLAIMER: The information in this leaflet is given in good faith. The company will not be liable for loss or damage howsoever caused including liability for negligence, which may be suffered by the user of the data contained therein. It is the user's responsibility to conduct all necessary tests to confirm the suitability of any product or system for their intended use. No guarantee of result is extended since conditions of use are beyond our control.
1. This cancels all previous literature on this product and is subject to revision without notice
2. Do not apply when temperature falls below 10o C or rises above 50o C and when relative humidity rises above 90%. Do not apply during rain, fog or mist.
3. Use off mixed paint within stipulated pot life period.
System Selection Guide
Health and Safety
Precaution
Shalimar Paints Ltd.: 4th Floor, Plot No. 64, Sector-44Gurgaon -122001, Haryana (India) | P: +91-124-4616600 | F: +91-124-4616659E: [email protected] | www.shalimarpaints.com
Acids Alkalis Solvents Salt Water
Good Excellent Excellent Excellent Excellent
Good Excellent Excellent Excellent Excellent
EXPOSURE
SPLASH & SPILLAGE
FUMES & OUTDOOREXPOSURE
NOTES
Please refer to the separate safety data sheet available with detailed information.
For proper curing of film, ambient temperature should not be lower than 10o C.
Chemical Resistance Guide
2
Rev
isio
n-1,
Apr
il 20
14
System Selection Guide
Chemical Resistance Guide
SURFACE
Epigard 5 HB ZincPhosphate PrimerRed/Grey
Epigard HPOffwhite Primer.
Bipigard CTE XL Black /Bipigard 580 HB CTE Black
Epigard solventlessepoxy Coating.
Epigard solventlessepoxy Coating.
Epigard solventlessepoxy Coating.
Epigard solventlessepoxy Coating.
ConcreteSurface