Supplementary Information Tuning the Dual Emissions of a Monoruthenium Complex with a Dangling Coordination Site by Solvents, O 2 , and Metal Ions Si-Hai Wu,* a Jiang-Yang Shao, b Zhong-Liang Gong, b Na Chen, a and Yu-Wu Zhong* b,c a School of Biomedical Sciences, Huaqiao University, Quanzhou, Fujian 362021, China. E-mail: [email protected] b CAS Key Laboratory of Photochemistry, CAS Research/Education Center for Excellence in Molecular Sciences, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China. E-mail: [email protected] c University of Chinese Academy of Sciences Beijing 100049, China Contents 1. Synthesis and Characterization 2. HPLC Analysis 3. Single-Crystal X-Ray Analysis 4. Spectroscopic Analysis 5. Emission Lifetime Analysis 6. DFT and TDDFT Calculations 7. Electrochemical Measurements S1 Electronic Supplementary Material (ESI) for Dalton Transactions. This journal is © The Royal Society of Chemistry 2017

Upload: others

Post on 14-Aug-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Tuning the Dual Emissions of a Monoruthenium Complex with ... · LC-20AD pumps, a SPD-M20A diode array detector, a CTO-20A oven, and a SIL-20A autosampler. HLPC grade solvents were

Supplementary Information

Tuning the Dual Emissions of a Monoruthenium Complex with a Dangling Coordination Site by Solvents, O2, and Metal Ions

Si-Hai Wu,*a Jiang-Yang Shao,b Zhong-Liang Gong,b Na Chen,a and Yu-Wu Zhong*b,c

aSchool of Biomedical Sciences, Huaqiao University, Quanzhou, Fujian 362021, China. E-mail:

[email protected] bCAS Key Laboratory of Photochemistry, CAS Research/Education Center for Excellence in

Molecular Sciences, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China.

E-mail: [email protected] cUniversity of Chinese Academy of Sciences Beijing 100049, China

Contents

1. Synthesis and Characterization

2. HPLC Analysis

3. Single-Crystal X-Ray Analysis

4. Spectroscopic Analysis

5. Emission Lifetime Analysis

6. DFT and TDDFT Calculations

7. Electrochemical Measurements

S1

Electronic Supplementary Material (ESI) for Dalton Transactions.This journal is © The Royal Society of Chemistry 2017

Page 2: Tuning the Dual Emissions of a Monoruthenium Complex with ... · LC-20AD pumps, a SPD-M20A diode array detector, a CTO-20A oven, and a SIL-20A autosampler. HLPC grade solvents were

1. Synthesis and Characterization

General. NMR spectra were recorded in the designated solvent on a Bruker Avance

spectrometer. Spectra are reported in ppm values from residual protons of the

deuterated solvent for 1H NMR (7.26 ppm for CDCl3 and 1.92 ppm for CD3CN).

Mass data were obtained with a Bruker Daltonics Inc. Apex II FT-ICR or Autoflex III

MALDI-TOF mass spectrometer. The matrix for matrix-assisted laser desorption

ionization time-of-flight (MALDI-TOF) measurement is -cyano-4-hydroxycinnamic

acid. Microanalysis was carried out using a Flash EA 1112 or Carlo Erba 1106

analyzer at the Institute of Chemistry, Chinese Academy of Sciences.

Synthesis of 2,5-di(N-methyl-N-(pyrid-2-yl)amino)pyrazine (dapz). A suspension

of 2,5-dibromopyazine (476 mg, 2.0 mmol), 2-(methylamino)pyridine (475 mg, 4.4

mmol), tris(dibenzylideneacetone)dipalladium (Pd2(dba)3, 183 mg, 0.20 mmol),

1,1'-bis(diphenylphosphino)ferrocene (dppf, 110 mg, 0.20 mmol), and NaOtBu (768

mg, 8.0 mmol) in 15 mL of dry toluene was heated at 130 C for 48 h under nitrogen

atmosphere. The resulting mixture was cooled to room temperature. The solvent was

removed under reduced pressure and the crude product was purified by column

chromatography on silica gel (eluent with petroleum ether/ethyl acetate 3/1) to afford

576 mg of dapz as a yellow solid in 98% yield. 1H NMR (300 MHz, CDCl3): δ 3.59 (s,

6H), 6.85 (t, J = 6.0 Hz, 2H), 7.03 (d, J = 8.4 Hz, 2H), 7.55 (t, J = 8.0 Hz, 2H), 8.31

(d, J = 4.8 Hz, 2H), 8.45 (s, 2H). 13C NMR (100 MHz, CDCl3): δ 36.16, 112.30,

116.73, 136.16, 137.74, 148.30, 148.62, 157.52. EI-MS (m/z): 292 for [M]+.

ESI-HRMS calcd for C16H17N6: 293.150921. Found: 293.150904.

S2

Page 3: Tuning the Dual Emissions of a Monoruthenium Complex with ... · LC-20AD pumps, a SPD-M20A diode array detector, a CTO-20A oven, and a SIL-20A autosampler. HLPC grade solvents were

Synhtesis of Complex [(bpy)2Ru(dapz)](PF6)2, 1(PF6)2. To a solution of

cis-[(bpy)2RuCl2] (103.8 mg, 0.20 mmol) in 8 mL of ethylene glycol was added the

above synthesized ligand dapz (58.4 mg, 0.20 mmol). The resulting mixture was

heated under microwave irradiation for 0.5 h (power = 325 W). After cooling to room

temperature, an excess of an aqueous solution of KPF6 was added. The resulting

precipitate was collected and purified by flash column chromatography on silica gel

using CH3CN/KNO3 (aq.) (200/1) as the eluent to give 177 mg of 1(PF6)2 as an orange

solid in 88% yield. 1H NMR (400 MHz, CD3CN): δ 3.37 (s, 3H), 3.47 (s, 3H),

6.81-6.86 (m, 2H), 6.96 (dd, J = 5.2, 2.0 Hz, 1H), 7.17 (t, J = 6.0 Hz, 1H), 7.28-7.33

(m, 2H), 7.39 (d, J = 4.0 Hz, 1H), 7.59-7.61 (m, 6H), 7.79-7.84 (m, 2H), 7.89 (t, J =

8.0 Hz, 1H), 7.94 (t, J = 8.0 Hz, 1H), 8.12 (t, J = 8.0 Hz, 1H), 8.16 (t, J = 8.0 Hz, 1H),

8.32-8.36 (m, 4H), 8.41 (d, J = 8.0 Hz, 1H), 8.51 (d, J = 8.4 Hz, 1H), 8.58 (d, J = 5.6

Hz, 1H). 13C NMR (100 MHz, CD3CN): δ 36.40, 41.44, 115.11, 116.78, 120.03,

121.66, 125.44, 125.54, 125.63, 125.94, 128.01, 128.51, 128.55, 128.89, 136.45,

136.95, 138.96, 139.12, 139.46, 139.54, 140.14, 140.84, 147.78, 149.06, 151.02,

152.12, 153.09, 153.23, 154.15, 154.64, 157.38, 158.51, 158.54, 158.56, 158.64,

160.05. MALDI-MS (m/z): 708.2 for [M 2PF6]+, 548.1 for [M 2PF6 bpy]+. Anal.

Calcd for C36H32F12N10P2RuH2O: C, 42.65; H, 3.38; N, 13.82. Found: C, 42.68; H,

3.73; N, 13.72.

S3

Page 4: Tuning the Dual Emissions of a Monoruthenium Complex with ... · LC-20AD pumps, a SPD-M20A diode array detector, a CTO-20A oven, and a SIL-20A autosampler. HLPC grade solvents were

Figure S1. 1H NMR spectrum of dapz in CDCl3.

Figure S2. 13C NMR spectrum of dapz in CDCl3.

3.00

1.01

1.04

1.01

0.96

0.96

3.59

6.83

6.84

6.86

7.03

7.05

7.26

7.53

7.56

7.58

8.29

8.31

8.45

0102030405060708090100110120130140150160170180190200f1 (ppm)

0

10000

20000

30000

40000

50000

60000

70000

80000

90000

1E+0513cyangwwwsh-8-31

S4

Page 5: Tuning the Dual Emissions of a Monoruthenium Complex with ... · LC-20AD pumps, a SPD-M20A diode array detector, a CTO-20A oven, and a SIL-20A autosampler. HLPC grade solvents were

Figu

ure S3. 1H NMMR spectrumm of 1(PF6)2 in

n CD3CN.

S5

Page 6: Tuning the Dual Emissions of a Monoruthenium Complex with ... · LC-20AD pumps, a SPD-M20A diode array detector, a CTO-20A oven, and a SIL-20A autosampler. HLPC grade solvents were

Figu

200

wshwsh-

ure S4. 13C N

170180190

-7-74

NMR spectrum

14150160

m of 1(PF6)2 i

12013040

in CD3CN.

90100110f1 (ppm)

607080 304050 01020

0

0

500

1000

1500

2000

2500

3000

3500

4000

4500

5000

5500

6000

6500

7000

7500

8000

S6

Page 7: Tuning the Dual Emissions of a Monoruthenium Complex with ... · LC-20AD pumps, a SPD-M20A diode array detector, a CTO-20A oven, and a SIL-20A autosampler. HLPC grade solvents were

2. HPLC Analysis

HPLC analysis was performed on a Shimadzu UFLC system consisting of two

LC-20AD pumps, a SPD-M20A diode array detector, a CTO-20A oven, and a

SIL-20A autosampler. HLPC grade solvents were obtained from Fisher Scientific. A

Shim-pack XR-ODS (Shimadzu, Japan) column (2.2 μm, 75 mm × 4.6 mm, i.d.) was

used for the analysis. Compounds were eluted with a gradient solvent of CH3CN in

water (10-90% over 0-10 min, followed by isocratic elution of 90% CH3CN for 5 min.

All solvents contain 0.1% of TFA. The flow rate was 1.0 mL/min. The detection

wavelengths were set at 360 nm and 450 nm for ligand dapz and complex 1(PF6)2,

respectively.

S7

Page 8: Tuning the Dual Emissions of a Monoruthenium Complex with ... · LC-20AD pumps, a SPD-M20A diode array detector, a CTO-20A oven, and a SIL-20A autosampler. HLPC grade solvents were

3. Single-Crystal X-Ray Analysis

The X-ray diffraction data were collected using a Rigaku Saturn 724 diffractometer

on a rotating anode (Mo-K radiation, 0.71073 Å) at 173 K. The structure was solved

using SHELXS-971 and refined with Olex2.2 The structure graphics were generated

using Olex2.

Table S1. Crystallographic data of 1(PF6)2.

compound 1(PF6)2

CCDC number 1570857

empirical formula C38H32F12N10P2Ru(CH2Cl2)2

formula weight 1165.58

crystal system triclinic

a (Å) 12.158(2)

b (Å) 12.408(3)

c (Å) 15.666(3)

V (Å3) 2225.7(9)

(°) 76.75(3)

(°) 85.54(3)

(°) 75.42(3)

Z value 2

Density (g/cm3) 1.739

R1 (final) 0.0841

wR2 (final) 0.2209

R1 (all) 0.0879

wR2 (all) 0.2247

1 Sheldrick, G. M. Acta Cryst. 2008, A64, 112. 2 Dolomanov, O. V.; Bourhis, L. J.; Gildea, R. J.; Howard, J. A. K.; Puschmann, H. J. Appl. Cryst. 2009, 42, 339.

S8

Page 9: Tuning the Dual Emissions of a Monoruthenium Complex with ... · LC-20AD pumps, a SPD-M20A diode array detector, a CTO-20A oven, and a SIL-20A autosampler. HLPC grade solvents were

Tabl

le S2. Selecte

com

1(P

ed Bond Leng

mpound bon

PF6)2 Ru

Ru

Ru

Ru

Ru

Ru

gths and Bon

nd lengths (Å

u(1)-N(1) 2.

u(1)-N(2) 2.

u(1)-N(3) 2.

u(1)-N(4) 2.

u(1)-N(5) 2.

u(1)-N(7) 2.

nd Angles

Å) b

.062(4) N

.063(4) N

.067(4) N

.066(4) N

.108(4) N

.070(4) N

bond angles (

N(1)-Ru(1)-N

N(2)-Ru(1)-N

N(2)-Ru(1)-N

N(3)-Ru(1)-N

N(4)-Ru(1)-N

N(5)-Ru(1)-N

()

N(4) 78.87(

N(3) 79.01(

N(5) 91.92(

N(5) 91.68(

N(5) 96.37(

N(7) 86.59(

(18)

(17)

(16)

(17)

(17)

(16)

S9

Page 10: Tuning the Dual Emissions of a Monoruthenium Complex with ... · LC-20AD pumps, a SPD-M20A diode array detector, a CTO-20A oven, and a SIL-20A autosampler. HLPC grade solvents were

4. Spectroscopic Analysis

All optical absorption spectra were obtained using a TU-1810DSPC spectrometer of

Beijing Purkinje General Instrument Co. Ltd. at room temperature in denoted solvents,

with a conventional 1.0 cm quartz cell.

Emission spectra were recorded using a F-380 spectrofluorimeter of Tianjin

Gangdong Sic. & Tech Development Co. Ltd, with a red-sensitive photomultiplier

tube R928F. Samples for emission measurement were obtained within quartz cuvettes

of 1 cm path length. Luminescence quantum yields were determined using quinine

sulfate in 1.0 M aq H2SO4 ( = 55%) or [Ru(bpy)3](PF6)2 ( = 9.5%) in degassed

acetonitrile solution as the standard; estimated uncertainty of is 10% or better.

250 300 350 400 450 500 550 6000.00

0.05

0.10

0.15

CH3CN

acetone CH

2Cl

2

DMSO DMF CH

3OH

/ 105

M-1 c

m-1

/ nm

Figure S5. Absorption spectra of dapz in different solvents.

S10

Page 11: Tuning the Dual Emissions of a Monoruthenium Complex with ... · LC-20AD pumps, a SPD-M20A diode array detector, a CTO-20A oven, and a SIL-20A autosampler. HLPC grade solvents were

Figure S6. (a) Excitation spectrum of dapz in CH3CN, monitoring for the emission centered at

460 nm. (b) Excitation spectra for 1(PF6)2 in CH3CN, monitoring for emission centered at 475 nm

ad 620 nm, respectively. The absorption spectra of two compounds are included for comparison.

400 500 600 700 8000.0

0.2

0.4

0.6

0.8

1.0

Em

issi

on in

ten

sity

/ nm

exci

:

320 nm 340 nm 360 nm 380 nm 400 nm 420 nm 440 nm 460 nm 480 nm 500 nm

Figure S7. Emission spectra of 1(PF6)2 in CH3CN at the excitation of different wavelength (exci).

250 300 350 400 450 500 550 600 6500.00

0.05

0.10

0.15

absorption spectrum excitation spectrum

Ab

sorb

an

ce

/ nm

250 300 350 400 450 500 550 600 6500.0

0.2

0.4

0.6

0.8

1.0

absorption spectrum excitation spectrum of

the emission at 475 nm excitation spectrum of

the emission at 620 nm

Abs

orba

nce

/ nm

(b)

(a)

S11

Page 12: Tuning the Dual Emissions of a Monoruthenium Complex with ... · LC-20AD pumps, a SPD-M20A diode array detector, a CTO-20A oven, and a SIL-20A autosampler. HLPC grade solvents were

5. Emission Lifetime Analysis

The luminescence decays were measured using a nanosecond flash photolysis setup

Edinburgh LP920 spectrometer (Edinburgh Instruments Ltd.), combined with a

Nd:YAG laser (Surelite II, Continuum Inc.). The sample was excited by a 355 nm

laser pulse (1 Hz, 15 mJ/pulse, fwhm ≈ 7 ns). A monochromator equipped with a

photomultiplier for collecting the spectral range from 300 to 850 nm was used to

analyze the luminescence decays. Data were analyzed by the online software of the

LP920 spectrophotometer.

Table S3. Emission lifetime data of 1(PF6)2 in different solvents.a

Solvent [ns] (N2-saturated) [ns] (air-equilibrated)

1 (A1) 2 (A2) av 1 (A1) 2 (A2) av

CH3CN 16 (0.038) 219 (0.006) 155 15 (0.014) 58 (0.015) 49

acetone 20 (0.018) 137 (0.0065) 103 17 (0.01) 63 (0.0093) 53

CH2Cl2 27 (0.016) 136 (0.024) 74 17 (0.025) 93 (0.0088) 67

DMSO -- 162 -- 146

DMF -- 122 -- 81

MeOH -- 52 -- 42

aMeasured at rt at 10-5 M. Excited at 355 nm. Detection wavelength is 625 nm. The data measured in CH3CN,

acetone, and CH2Cl2 is simulated by a biexponential decay, where the shorter component 1 is very likely from the

excitation laser source (lifetime around 20 ns). The emissions at 625 nm in these solvents are relatively weaker.

The longer component 1 is reported in Table 1 in the main article, which is believed to be associated with the true

emission at 625 nm. The data measured in DMSO, DMF, and MeOH is well simulated by a monoexponential

decay. In case of biexponential decay, the average lifetime (av) is given for comparison. av = [A1(1)2 +

A2(2)2]/(A11 + A22).

S12

Page 13: Tuning the Dual Emissions of a Monoruthenium Complex with ... · LC-20AD pumps, a SPD-M20A diode array detector, a CTO-20A oven, and a SIL-20A autosampler. HLPC grade solvents were

Figure S8. Emission decay and simulated curve (black curves) of 1(PF6)2 in different

air-equilibrated (blue curves) or N2-saturated (red curves) solvents.

Figure S9. Transition emission spectra of 1(PF6)2 in CH3CN at room temperature measured by a

nanosecond flash photolysis setup using the Edinburgh LP920 spectrometer. Panel (b) shows the

enlarged plots of (a).

0 200 400 600 8000.000

0.005

0.010

0.015

0.020

0.025

0.030

0.035

air-equilibriated in CH2Cl

2

N2-saturated in CH

2Cl

2

Em

issi

on

inte

nsi

ty

t / ns

0 200 400 600 800 10000.00

0.01

0.02

0.03

air-equilibriated in CH3CN

N2-saturated in CH

3CN

Em

issi

on

inte

nsity

t / ns0 200 400 600 800 1000 1200

0.00

0.01

0.02

air-equilibriated in acetone N

2-saturated in acetone

Em

issi

on

inte

nsity

t / ns

0 200 400 600 800 1000 1200 14000.00

0.02

0.04

air-equilibriated in DMF N

2-saturated in DMF

Em

issi

on

inte

nsity

t / ns

0 200 400 600 800 1000 1200 1400

0.00

0.01

0.02

0.03

air-equilibriated in DMSO N

2-saturated in DMSO

Em

issi

on

inte

nsi

tyt / ns

0 200 400 600 800 10000.000

0.005

0.010

0.015

0.020

air-equilibriated in DMSO N

2-saturated in DMSO

Em

issi

on

inte

nsi

ty

t / ns

(a)

(c)

(e)

(b)

(d)

(f)

400 450 500 550 600 650 7000.0

0.2

0.4

0.6

0.8

1.0

Em

issi

on in

tens

ity

/ nm

80 ns 90 ns 100 ns 110 ns 120 ns 130 ns 140 ns 150 ns 160 ns

400 450 500 550 600 650 7000.00

0.02

0.04

0.06

0.08

0.10

0.12

0.14

0.16

0.18

0.20

Em

issi

on in

tens

ity

/ nm

80 ns 90 ns 100 ns 110 ns 120 ns 130 ns 140 ns 150 ns 160 ns

(a) (b)

S13

Page 14: Tuning the Dual Emissions of a Monoruthenium Complex with ... · LC-20AD pumps, a SPD-M20A diode array detector, a CTO-20A oven, and a SIL-20A autosampler. HLPC grade solvents were

Figu

77 K

mon

The

For t

For t

ure S10. Scre

K for the e

noexponential

average lifet

the emission

the emission

een shots capt

mission ban

l decay.

ime av was c

band at (a) 4

band at (b) 6

tured during t

d at (a) 450

calculated by

50 nm: 1 = 0

620 nm: 1 = 2

the lifetime m

0 and (b) 6

av = [A1(1)2

0.65 ns, A1 =

261 ns, A1 =

measurement

620 nm. Bot

2 + A2(2)2]/(A

839, 2 = 6.7

145, 2 = 284

of 1(PF6)2 in

th data were

A11 + A22).

70 ns, A2 = 16

43 ns, A2 = 78

n glassy CH3C

e simulated

63, av = 4.7 n

8, av = 2.5 s

CN at

by a

ns.

s.

S14

Page 15: Tuning the Dual Emissions of a Monoruthenium Complex with ... · LC-20AD pumps, a SPD-M20A diode array detector, a CTO-20A oven, and a SIL-20A autosampler. HLPC grade solvents were

Figure S11. Emission spectral changes of air-equilibrated solution of 1(PF6)2 in different solvents

upon bubbling with N2. Excited at 360 nm for all.

400 500 600 700 800 9000

30

60

90

120

150

180degassed 480s

air-equlibrated

emis

sion

inte

nsity

/ nm

MeOH

400 500 600 700 800 9000

7

14

21

28

35

42

emis

sion

inte

nsity

/ nm

degassed 300s

air-equlibrated

CH3CN acetone

400 500 600 700 800 9000

700

1400

2100

2800

emis

sion

inte

nsity

/ nm

degassed 600s

air-equlibrated

DMSO

400 500 600 700 800 9000

130

260

390

520

emis

sion

inte

nsity

/ nm

degassed 300s

air-equlibrated

CH2Cl2

400 500 600 700 800 9000

70

140

210

280

emis

sion

inte

nsity

/ nm

degassed 300s

air-equlibrated

DMF

(b)

(a)

(c)

(e)

(d)

(f)

400 500 600 700 800 9000

160

320

480

640

800

960

degassed 480s

air-equlibrated

emis

sion

inte

nsity

/ nm

S15

Page 16: Tuning the Dual Emissions of a Monoruthenium Complex with ... · LC-20AD pumps, a SPD-M20A diode array detector, a CTO-20A oven, and a SIL-20A autosampler. HLPC grade solvents were

Figure S12. Normalized emission spectra of 1(PF6)2 (normalized to the emission band at 640 nm)

in air-equilibrated or N2-saturated solution. Excited at 360 nm for all.

MeOH

CH3CN

acetone

DMSOCH2Cl2

DMF

(b)

(a)

(c)

(e)

(d)

(f)

400 500 600 700 800 9000.0

0.2

0.4

0.6

0.8

1.0

air-equilibrated N

2-saturated

no

rmal

izat

ion

emis

sion

/ nm

400 500 600 700 800 9000.0

0.2

0.4

0.6

0.8

1.0

air-equilibrated N

2-saturated

no

rmal

izat

ion

emis

sion

/ nm

400 500 600 700 800 9000.0

0.2

0.4

0.6

0.8

1.0

air-equilibrated N

2-saturated

norm

aliz

atio

n em

issi

on

/ nm

400 500 600 700 800 9000.0

0.2

0.4

0.6

0.8

1.0 air-equilibrated N

2-saturated

nor

mal

izat

ion

emis

sion

/ nm

400 500 600 700 800 9000.0

0.2

0.4

0.6

0.8

1.0

air-equilibrated N

2-saturated

norm

aliz

atio

n em

issi

on

/ nm

400 500 600 700 800 9000.0

0.2

0.4

0.6

0.8

1.0 air-equilibrated N

2-saturated

nor

mal

izat

ion

emis

sion

/ nm

S16

Page 17: Tuning the Dual Emissions of a Monoruthenium Complex with ... · LC-20AD pumps, a SPD-M20A diode array detector, a CTO-20A oven, and a SIL-20A autosampler. HLPC grade solvents were

Figu

irrad

ure S13. (a) A

diation) chang

Absorption sp

ges of 1(PF6)

pectral, (b) e

2 (5 10-5 M

emission spec

M in CH3CN, 2

ctral, and (c)

298 K) upon

emission col

the addition o

lor (under 36

of Hg(ClO4)2

5 nm

2.

S17

Page 18: Tuning the Dual Emissions of a Monoruthenium Complex with ... · LC-20AD pumps, a SPD-M20A diode array detector, a CTO-20A oven, and a SIL-20A autosampler. HLPC grade solvents were

Figu

irrad

ure S14. (a) A

diation) chang

Absorption sp

ges of 1(PF6)

pectral, (b) e

2 (5 10-5 M

emission spec

M in CH3CN, 2

ctral, and (c)

298 K) upon

emission col

the addition o

lor (under 36

of Cu(ClO4)2

5 nm

.

S18

Page 19: Tuning the Dual Emissions of a Monoruthenium Complex with ... · LC-20AD pumps, a SPD-M20A diode array detector, a CTO-20A oven, and a SIL-20A autosampler. HLPC grade solvents were

Figu

irrad

ure S15. (a) A

diation) chang

Absorption sp

ges of 1(PF6)

pectral, (b) e

2 (5 10-5 M

emission spec

M in CH3CN, 2

ctral, and (c)

298 K) upon

emission col

the addition o

lor (under 36

of Fe(ClO4)3.

5 nm

.

S19

Page 20: Tuning the Dual Emissions of a Monoruthenium Complex with ... · LC-20AD pumps, a SPD-M20A diode array detector, a CTO-20A oven, and a SIL-20A autosampler. HLPC grade solvents were

Figu

irrad

ure S16. (a) A

diation) chang

Absorption sp

ges of 1(PF6)

pectral, (b) e

2 (5 10-5 M

emission spec

M in CH3CN, 2

ctral, and (c)

298 K) upon

emission col

the addition o

lor (under 36

of Ni(ClO4)2.

5 nm

.

S20

Page 21: Tuning the Dual Emissions of a Monoruthenium Complex with ... · LC-20AD pumps, a SPD-M20A diode array detector, a CTO-20A oven, and a SIL-20A autosampler. HLPC grade solvents were

Figu

irrad

ure S17. (a) A

diation) chang

Absorption sp

ges of 1(PF6)

pectral, (b) e

2 (5 10-5 M

emission spec

M in CH3CN, 2

ctral, and (c)

298 K) upon

emission col

the addition o

lor (under 36

of Zn(ClO4)2

5 nm

.

S21

Page 22: Tuning the Dual Emissions of a Monoruthenium Complex with ... · LC-20AD pumps, a SPD-M20A diode array detector, a CTO-20A oven, and a SIL-20A autosampler. HLPC grade solvents were

Figu

1.0 e

ure S18. 1H N

equiv (upper)

NMR spectra

) of Hg(ClO4)

al changes of

)2.

1(PF6)2 in C

CD3CN upon tthe addition oof 0.5 (middl

le) or

S22

Page 23: Tuning the Dual Emissions of a Monoruthenium Complex with ... · LC-20AD pumps, a SPD-M20A diode array detector, a CTO-20A oven, and a SIL-20A autosampler. HLPC grade solvents were

6. DFT and TDDFT Calculations

DFT calculations were carried out by using the B3LYP exchange correlation

functional3 and implemented in the Gaussian 09 package.4 The input files were

generated from the single-crystal X-ray data. The electronic structures were optimized

with a general basis set with the Los Alamos effective core potential LANL2DZ basis

set for Ru and 6-31G* for other atoms.5 The solvation effects in CH3CN were

included for all calculations. No symmetry constraints were used in the optimization

(nosymm keyword was used). Frequency calculations were performed with the same

level of theory to ensure the optimized geometries to be local minima. All orbitals

were computed at an isovalue of 0.03 e bohr-3. TDDFT calculations were performed

on the DFT-optimized structures on the same level of theory.

3 Lee, C.; Yang, W.; Parr, R. G. Phys. Rev. B 1988, 37, 785. 4 Frisch, M. J.; Trucks, G. W.; Schlegel, H. B.; Scuseria, G. E.; Robb, M. A.; Cheeseman, J. R.; Montgomery, J. A.; Vreven, Jr. T.; Kudin, K. N.; Burant, J. C.; Millam, J. M.; Iyengar, S. S.; Tomasi, J.; Barone, V.; Mennucci, B.; Cossi, M.; Scalmani, G.; Rega, N.; Petersson, G. A.; Nakatsuji, H.; Hada, M.; Ehara, M.; Toyota, K.; Fukuda, R.; Hasegawa, J.; Ishida, M.; Nakajima, T.; Honda, Y.; Kitao, O.; Nakai, H.; Klene, M.; Li, X.; Knox, J. E.; Hratchian, H. P.; Cross, J. B.; Adamo, C.; Jaramillo, J.; Gomperts, R.; Stratmann, R. E.; Yazyev, O.; Austin, A. J.; Cammi, R.; Pomelli, C.; Ochterski, J. W.; Ayala, P. Y.; Morokuma, K.; Voth, G. A.; Salvador, P.; Dannenberg, J. J.; Zakrzewski, V. G.; Dapprich, S.; Daniels, A. D.; Strain, M. C.; Farkas, O.; Malick, D. K.; Rabuck, A. D.; Raghavachari, K.; Foresman, J. B.; Ortiz, J. V.; Cui, Q.; Baboul, A. G.; Clifford, S.; Cioslowski, J.; Stefanov, B. B.; Liu, G.; Liashenko, A.; Piskorz, P.; Komaromi, I.; Martin, R. L.; Fox, D. J.; Keith, T.; Al-Laham, M. A.; Peng, C. Y.; Nanayakkara, A.; Challacombe, M.; Gill, P. M. W.; Johnson, B.; Chen, W.; Wong, M. W.; Gonzalez, C.; Pople, J. A. Gaussian 09, revision A.2; Gaussian, Inc.: Wallingford CT, 2009. 5 (a) Dunning, T. H.; Hay, P. J. In Modern Theoretical Chemistry; Schaefer, H. F., Ed.; Plenum: New York, 1976; Vol. 3, p 1. (b) Hay, P. J.; Wadt, W. R. J. Chem. Phys. 1985, 82, 299.

S23

Page 24: Tuning the Dual Emissions of a Monoruthenium Complex with ... · LC-20AD pumps, a SPD-M20A diode array detector, a CTO-20A oven, and a SIL-20A autosampler. HLPC grade solvents were

Figure S19. TDDFT-predicted excitations (red lines) of (a) dapz and (b) 12+. The absorption

spectra of dapz and 1(PF6)2 (black curves) are included for comparison.

(b)

(a)

250 300 350 400 450 500 550 6000.0

0.1

0.2

0.3

0.4

0.5

/

10

5 M-1 c

m-1

osci

llato

r st

reng

th

/ nm

0.00

0.05

0.10

0.15

250 300 350 400 450 500 550 6000.0

0.1

0.2

0.3

0.4

/

105 M

-1 c

m-1

osci

llato

r st

reng

th

/ nm

0.0

0.3

0.6

0.9

S24

Page 25: Tuning the Dual Emissions of a Monoruthenium Complex with ... · LC-20AD pumps, a SPD-M20A diode array detector, a CTO-20A oven, and a SIL-20A autosampler. HLPC grade solvents were

Table S4. TDDFT results.a

Complex Sn E [ev] [nm] f Dominant transition(s)

(percentage contributionb)

assignmentc

dapz

1 3.41 364 0.283 HOMO LUMO (98%) ILCT

2 3.85 322 0.2441 HOMO LUMO+1 (96%) ILCT

3 4.00 310 0.0354 HOMO LUMO+2 (88%) ILCT

5 4.15 299 0.2399 HOMO LUMO+3 (96%) ILCT

6 4.58 271 0.1799 HOMO LUMO+4 (92%) ILCT

7 4.65 267 0.0155 HOMO-2 LUMO (65%) 8 4.74 262 0.0473 HOMO-1 LUMO+1 (76%)

9 4.95 251 0.0288 HOMO-1 LUMO+2 (73%)

12+

2 2.75 452 0.0384HOMO-1 LUMO+1 (44%)

HOMO-2 LUMO+11 (41%)

MLbpyCT

MC

7 3.06 406 0.0952 HOMO-2 LUMO (52%) MLbpyCT

8 3.09 401 0.0879 HOMO LUMO+2 (88%) ILCT(dapz)

9 3.15 395 0.0497HOMO-3 LUMO (22%)

HOMO-3 LUMO+1 (35%) MLbpyCT

10 3.33 372 0.0184HOMO-2 LUMO+2 (47%)

HOMO-1 LUMO+2 (33%) MLpyrazineCT

11 3.40 365 0.0425HOMO-2 LUMO+2 (45%)

HOMO-1 LUMO+2 (39%)

MLpyrazineCT

MLpyrazineCT

13 3.53 351 0.0726HOMO-3 LUMO+2 (34%)

HOMO LUMO+3 (33%)

MLpyrazineCT

LdapzLbpyCT

17 3.69 336 0.0498

HOMO-3 LUMO+11 (28%)

HOMO-3 LUMO+12 (10%)

HOMO LUMO+3 (13%)

HOMO LUMO+4 (19%)

MC

MC

LdapzLbpyCT

ILCT(dapz)

19 3.75 331 0.0163

HOMO-2 LUMO+3 (17%)

HOMO-1 LUMO+3 (33%)

HOMO LUMO+5 (26%)

MLbpyCT

MLbpyCT

LdapzLbpyCT aMolecular orbitals are shown in Figures S17 and S18.

S25

Page 26: Tuning the Dual Emissions of a Monoruthenium Complex with ... · LC-20AD pumps, a SPD-M20A diode array detector, a CTO-20A oven, and a SIL-20A autosampler. HLPC grade solvents were

Figu

an is

ure S20. Isod

sovalue of 0.0

density plots

03.

of frontier mmolecular orbiitals of dapz. All orbitals wwere comput

ted at

S26

Page 27: Tuning the Dual Emissions of a Monoruthenium Complex with ... · LC-20AD pumps, a SPD-M20A diode array detector, a CTO-20A oven, and a SIL-20A autosampler. HLPC grade solvents were

Figu

isov

ure S21. Isod

alue of 0.03.

density plots oof frontier mo

olecular orbittals of 12+. Alll orbitals werre computed

at an

S27

Page 28: Tuning the Dual Emissions of a Monoruthenium Complex with ... · LC-20AD pumps, a SPD-M20A diode array detector, a CTO-20A oven, and a SIL-20A autosampler. HLPC grade solvents were

7. Electrochemical Measurements

All electrochemical measurements were taken using a CHI 660D potentiostat with

one-compartment electrochemical cell under an atmosphere of nitrogen. All

measurements were carried out in CH3CN containing 0.1 M nBu4NClO4 as the

supporting electrolyte at a scan rate of 100 mV/s (for cyclic voltammetry). The

working electrode was a glassy carbon disk electrode (d = 3 mm). The electrode was

polished prior to use with 0.05 m alumina and rinsed thoroughly with water and

acetone. A large area platinum wire coil was used as the counter electrode. All

potentials are referenced to Ag/AgCl electrode in saturated aqueous NaCl without

compensation for the liquid junction potential. Potentials vs ferrocene+/0 can be

deduced by subtracting 0.45 V.

Figure S22. Cyclic voltammograms (black curves) and differential pulse voltammograms (red

curves) of (a) dapz and (b) 1(PF6)2 in 0.1 M Bu4NClO4/CH3CN at a scan rate of 100 mVs-1.

-2.0 -1.5 -1.0 -0.5 0.0 0.5 1.0 1.5 2.0-60

-40

-20

0

20

40

60

I /

A

E / V vs Ag/AgCl

-2.0 -1.5 -1.0 -0.5 0.0 0.5 1.0 1.5 2.0

-20

0

20

40

60

80

I /

A

E / V vs Ag/AgCl

(a)

(b)

S28