Page 1: tunnel lighting 2

Tunnel lightingFront accessComposite material

The design of the PF5 luminaire provides convenient reversibility of the protector.Depending on the type of application, it can be inclined either at an angle of 0° or 13°.

The PF5 luminaire offers a wide range of reflectors. It can take up to three opticalcompartments simultaneously.

APPLICATIONS

All types of tunnel. Particularly suitable for tunnels subject to

aggressive environments (high humidity, snow clearing salts,

tunnels through high mountains.

Lighting installation options:

• Counter Beam and Pro Beam (entrance zone)

• Symmetrically (entrance zone and interior zone)

• Wall mounting.

ADVANTAGES

• Entirely non-corrodible luminaire.

• Reversible protector allowing two types of inclination.

• Tightness level: IP 66. Double gasket.

• Can be washed with a high pressure jet.

• Wide range of reflectors.

• Mechanical robustness. Self-quenching material.

• Use of twin reflectors allows easy transition from day to

night level.

DESCRIPTION

Luminaire made of glass reinforced polyester composed of

two parts: a casing containing the reflector and a reversible

protector. This reversibility enables the PF5 to be installed with

the protector inclined at 0° or 13°.

Two closing levers mounted on the sides of the casing give

access to the control gear and the lamp.

A glass with extremely high thermal and mechanical

resistance is sealed into the protector frame.

The tightness of the luminaire (IP 66) - optical compartment

and control gear - is ensured by a double gasket with

chicanes.

OPTIONS

• Electrical disconnection when opening the luminaire.

• Closing levers in composite material.

PF5

Tightness level IP 66

Impact resistance (glass/casing) IK 08 / IK 10

Fire behaviour 0% halogen

Self-quenching

(VO according to UL94)

Class of electrical insulation I or II

Weight (empty) 17,5 kg

According to standard EN 60598.1.2.3

The PF5 is a luminaire made from a composite material resistant to all types of cor-rosion, even where the environment is particularly aggressive (high humidity, snowclearing salts, tunnels through high mountains).

Page 2: tunnel lighting 2

Two easily dismantled stainless steel axles allow the pro-tector to be reversed. Once the axles have been inserted,their position is locked.

Mounting by screws

Mounting by screws and tilting mechanism

REVERSIBILITY OF THE PROTECTOR

INSTALLATION

ELECTRICAL INSTALLATION

Power supply interfacing possibilities:

• by compression glands: looped feed possible.

• by exit cable and moulded plug (3 or 5 contacts) that can be dismantled.

• by a moulded base (3 or 5 contacts) that can be dismantled.

Other types of mountings are available.Please consult us.

PF5

Due to the fact that the lower and upper hinges match up, the PF5 protector is reversible. It can either be incli-ned or lie parallel to the casing. The PF5 with inclined protector is particularly ideal for wall mounted applica-tions. This device removes the necessity of installing the luminaire at an angle.

Adaptable

Standard =

440 mm

480 mm

30 m

m

66 m

m

200 mm AdaptableStandard = 646 mm

Page 3: tunnel lighting 2

In other cases, the lamp can be accessed directly or via alampholder support plug.

Installation and replacement of the controlgear plate are facilitated by a retainingcable. The plate remains suspended aftertwo mounting screws have been undone.

The PF5 is a luminaire with front access. The luminaire opensvia two lateral stainless steel closing levers. Following thisoperation, the protector pivots around two hinges.

DIMENSIONS

MAINTENANCE

As an option, the PF5 can be fitted with closing levers incomposite material.

When the optical compartment is Sealsafe® (see lamp table),the lamp can be accessed by simple rotation of the lamphol-der support plug.

715 mm

715 mm480 mm

545

mm

200

mm

260

mm

195

mm

Page 4: tunnel lighting 2

PF5

PHOTOMETRY

LAMPS

Reflector 1289

High pressure sodium 400 W

Applications:• Entrance zone

Applications: • Interior zone• The use of 2*1627 reflectors facilitates

the transition from day to night level byswitching off one light source.

Applications: • Interior zone

600 500 400 300 200

210°/330° 90°/270°

Ceiling (Counter Beam)Reflector 1585

High pressure sodium 400 W

Applications: • Entrance zone

800 656 512 368 224 80

90°/270°

Ceiling (Counter Beam)Reflector 1516

High pressure sodium 400 W

Applications: • Entrance zone

600 500 400 300 200 100

90°/270°

CeilingReflector 1289

High pressure sodium 150 W

Applications: • Entrance zone• Interior zone

20°/160° 90°/270°

400 320 240 160 80

Ceiling (double reflector)Reflectors: 2 x 1627

High pressure sodium 150 W

500 400 325 250 120 80

25°/155° 90°/270°

CeilingReflector 1170

High pressure sodium 150 W

300 250 200 250 100

0°/180° 90°/270°

Applications: • Entrance zone• Interior zone

Ceiling (Counter Beam)Reflector 1397

High pressure sodium 400 W

Applications: • Entrance zone

740 610 480 350 220 90

90°/270°

PlafondReflector 1548

High pressure sodium 400 W

360 300 240 180 120 60

0°/180° 90°/270°

Ceiling (Counter Beam)Reflector 1587

High pressure sodium 400 W

Applications: • Entrance zone

600 500 400 300 100

90°/270°

Wall mounting

(*) Sealsafe® version optional.Please consult us for other light sources:• Induction lamps (55 W, 85 W and 160 W)• Two or three compact fluorescent lamps (55 W)• Two low pressure sodium lamps (66 W)

Lamp Reflector

1289 2 or 3 x 1627 1170 1585 1587 - 1516(Sealsafe®)(*) (Sealsafe®)(*) 1 or 2 x 1548 (Sealsafe®)(*) 1397

- 50 W - - -

High - 70 W - - -

Pressure 100 W 100 W 100 W 100 W 100 W

Sodium 150 W 150 W 150 W 150 W 150 W

250 W - 250 W 250 W 250 W

400 W - 400 W 400 W 400 W