Turbo Freeze function
Version 1.0
Siena
Chest Freezer
Range 2011
Whirlpool EMEA
Service Competence Center
Office +49-(0)711-81071-3551
Mobile +49-(0)172-7505946
Stefan Bässler
Service Engineer FSS & Food Preparation
Chapter list
Installation
IFU
Operations
Control System Overview – Block Diagram
General Description of Basic Operation
Service State
Fail Message state
Check Software version
Software version state
Service Bit state
Alarm Information state
Temperature selection
Compressor management
Alarms
Resistance vs. temperature
Pictures / Drawings User Interface Layout
Components
Unit
Overview
Defrost drain outlet
Defrost drain outlet flap / cabinet
Basket with fan space seperator
Door look
Rear view
Compressor connection block
Marketing Info
Ramp up plan
Jet Freezing believability scheme
Chapter list
Repair Guide Line
Disassembling Cover light unit
Disassembling Lamp unit
Disassembling Turbo Freeze ventilation
Control System
Rear wheel disassembly
Disassembling Compressor Connection Block
Door hinges
Door handle
Door push-in gasket
Technical data
Electronic Board “Hercules”
Fan motor / Lamp
Lamp
Novelties Highlander production
Overview
Insulation
Current and new design of
compartment / bottom bar
Installation
IFU
Whirlpool Bauknecht
Marketing info
Ramp up plan
Brand new 12nc new comm. Code NET VOLUME TOTAL (L) STRUCTURE
Whirlpool854909096010
WH3213 A+ ET 310 big
Whirlpool854908096010
WH2513 A+ ET 251 big
Bauknecht855278101010
GTE 310 Turbo A+ 310 big
Bauknecht855234601030
GTE 205 Turbo A+ 204 Small
Whirlpool854909896010
WH4014 A+ ET 388 big
Whirlpool854907096000
WH2013 A+ ET 212 Small
SOP from week 18 / 2011 on
Marketing info
Jet Freezing believability scheme
“Technology from professionals… ... to respect food nutritionals and taste”
A -50% cut in time for freezing 4 kilos of food
+30% vitamins preserved in the food vs. a standard
conservation
= frost propagation area for Jet Freezing
Operations
Control System Overview - Block Diagram
Operations
General Description of Basic Operation
The control system includes the control board, wiring harness, power cord, light bulb,
compressor motor & NTC sensor.
The control board manages the on/off cycles of the compressor motor.
The control board monitors also the ambient sensor.
The light bulb is controlled by mechanical switch. There is no AC feedback input in the
control board.
Operations
Service State
Service State
This state is engaged when the Service technician interacts with the appliance in order to check if it is working
properly or not. During the firsts 30sec after the product energizing, independently of any other consideration, the
system will search for the Service Password.
The „Service‟ state will be engaged when:
1. Set-point == Eco
2. The Service technician presses and hold for 5sec the temperature setting push button SW1
Service state functional behavior
After entering in „Service‟ state, the compressor load & the LED3 (Jet Freezing (yellow)), LED2 (green), LED1 (green)
will be turned OFF.
The LED4 (Alarm (red)) will be forced ON.
The Service technician will use the temperature setting push button SW1 (waiting at least 3sec since the „Service‟
mode activation) to advance the steps of the „Service‟ state mode in order to evaluate the loads behavior and the
LED‟s/push button functionality. The LED‟s will be turned ON/OFF according to the following sequence:
Operations
Service State
End of „Service‟ Mode:
· When reached the last step (5), press the temperature setting push button SW1 once more to
show test results
· Time-out of service State: 10min
Operations
Fail Message state
Test result:
When service test is finished, result can be:
· PASS
Conditions:
· End service mode by end service & temperature sensor is OK
System Action:
· All LED‟s ON for 1sec. then all LED‟s OFF for 1 sec. then the default set point engage
NOT PASS
Conditions:
- Temperature sensor fails or timeout
Service State FAIL:
· Transition 1: done automatically after 2s from the current state start
· Transition 2: performed after SW1 becomes pressed
· Transition 3: done automatically after 2sec from the current state start
· Immediately after entering the „Power up‟ state, the default set point will be restored
FAIL Message state:
In case of a sensor defect, all LED‟s will blink.
Operations
Check Software version, Service Bit Alarm Code routine
User action:
· During the first step of the service test routine, press the temperature setting push button SW1 for 5sec
System Action:
· show the software version, Service bit information and the Alarms information as described below:
Transition Action:
· Transitions 1 to 3 occur when the user presses the button SW1
End System Action:
· After transition 3 return to ‘Service’ routine, step 2
Operations
Software version state
System Action:
· Show the software version according to the table below:
Operations
Service Bit state
System Action:
· show the ‘Service’ bit state according to the table below:
Service routine completed:
· All points of previous service test have been done.
Service Mode not finalized or end service by time-out:
· Time-out of previous service State: 10min
Operations
Alarm Information state
System Action:
· Show last alarm stored into non-volatile memory.
Just one alarm will be saved into the non-volatile memory and shown through the User Interface
following the indication as defined in the table below.
NOTE:
Immediately after Test Procedure engagement, the default start conditions shall be restored in the
not volatile memory in order to have the DEFAULT parameters configuration at next power up.
Operations
Temperature selection
Operations
Compressor management
SET POINTCompressor
Start
Compressor
StopTimer
ECO -13,1 °C -13,3°C
Normal -14,9 °C -15,1°C
Intensive -16,7°C -16,9°C
Fast Freezing compressor runs continuously 50 hours
Jet Freezing compressor runs continuously 6 hours
Sensor failure mode:
If the sensor becomes unreliable, the compressor will be time driven
· 15min OFF
· 45min ON
until the failure condition disappears.
Operations
Alarms
Over temperature Alarm
This alarm will provide a warning signal to the user if a dangerous Over temperature has been achieved during the
normal operation mode due to whatever causes (door not closed, damaged gasket, etc.).
Alarms priorities
Here below the alarms priorities:
1. Sensor failure
2. Over temperature alarm
Over temperature alarm shall be activated if (T > -8°C) since at least 30min. this condition does not apply at the plug in.
It is turned automatically off if (T < -9°C).
If the over temperature alarm becomes engaged:
· LED4 will blink
If the over temperature alarm becomes disengaged:
· LED4 will stop blinking
Over temperature alarm status will be saved in the non volatile memory only if:
T > -8°C AND Product_On > PRODUCT_TIME_ON (6h)
Operations
Resistance vs. temperature
Resistance vs. temperature NTC values
Operations
Pictures / Drawings User Interface layout
Siena Chest Freezer - User Interface layout
Components
Unit
Components
Overview
Components
Defrost drain outlet
Components
Defrost drain outlet flap / cabinet
Components
Basket with fan space seperator
Fan space seperator
Components
Door Look
Components
Rear view
Start capacitorConnection block
with PTC unit Compressor Condenser
Components
Compressor connection block
Start capacitor Connection block with PTC unit
Disassembly part
Cover light unit
Release both hooks with screwdriver
Disassembly part
Lamp unit
Remove both screw„s
Disassembly part
Lamp unit
Release lamp cover
Release lamp unit
Disconnect cable„s
with telephone
pliers
Disassembly part
Turbo Freeze ventilation
Release both screw„s
Disassembly part
Turbo Freeze ventilation
Note: Gasket of wiring must fit prober in connector
Disassembly part
Turbo Freeze ventilation
Motor support, fan motor
& fan housing
Disassembly part
Turbo Freeze ventilation
Disassembly part
Control System
Remove sticking inlay with a small cutter
In case of a service intervention to exchange
the controlbord a new inlay is required
Disassembly part
Control System
Disassembly part
Rear wheel disassembly
Push in the metal flap
Pull out metal pin
Remove wheel
Disassembly part
Compressor Connection Block
Disassembly part
Compressor Connection Block
Remove earth screwPull out the connection unit (connection pins)
from compressor
Disassembly part
Door hinges
Disassembly part
Door handle
Pull out both cap„s Lose both screw„s
Lift up handle
Disassembly part
Door push-in gasket
Technical Data
Electronic Board “Hercules”
Operating voltage & frequency 220 – 240V / 50 Hz)
Technical Data
Fan motor / Lamp
Volt input: 220 / 240 V 50 / 60 Hz
Power: 6 W + / - 10%
Speed: 2000 rpm
Working temperature: - 30°C / + 45°C
E14 15W 220V
Clear
Service code : 4819 134 88135
Factory usage code : 11 / 30 / 36 / 50
Novelties Highlander production
Overview
• Reduce the variants from 7 to 4
• Market implementation first quarter of 2012
• Bigger insulation
• New design of door to avoid ice formation (cabinet frame and door).
• New energy class A++
• Skin condenser on 3 faces to avoid condensation on cabinet and gasket
• Redesign of motor niche
Novelties Highlander production
Insulation
Current production 56mm Highlander production extended to 86mm
Novelties Highlander prodution
Current and new design of compartment / bottom
bar
Current design of compartment / bottom bar
New design of compartment / bottom bar