versafast M16 versafast ® Connectivity Products Part Number Keys G2 Cordsets G6 Receptacles G12 Tees G30 Field Wireables G35 Closure Caps G38 M16 threaded connectors 5 thru 8, 12, 14 and 19-pin Up to 8 Amp, 300 Volt rated Multiple tee configurations IEC IP67 protection Signal consolidation Features Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Upload: nguyenliem

Post on 04-Jan-2017

246 views

Category:

Documents


1 download

TRANSCRIPT

  • ve

    rs

    afa

    st

    M16 versafast Connectivity Products

    Part Number Keys G2

    Cordsets G6

    Receptacles G12

    Tees G30

    FieldWireables G35

    Closure Caps G38

    M16 threaded connectors 5 thru 8, 12, 14 and 19-pin Up to 8 Amp, 300 Volt rated Multiple tee configurations IEC IP67 protection Signal consolidation

    Features

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

    http://www.clrwtr.com/TURCK-Versafast.htm

  • M16 versafast Connectivity Products

    Cordset Part Number Key

    5 = 56 = 67 = 78 = 8

    12 = 1214 = 1419 = 19

    Number of Pins

    M16 versafast Cordset

    5-Pin084 = 5x18 AWG BN, BU, WH, BU, BK, GY

    6-Pin085 = 6x18 AWG BN, BU, WH, BU, BK, GY, PK

    7-Pin086 = 7x18 AWG WH, BN, GN, YE, GY, PK, BU

    8-Pin087 = 8x18 AWG WH, BN, GN, YE, GY, PK, BU, RD

    12-Pin001 = 12x22 AWG BN, BU, WH, GN, YE, GY, PK, RD, BK, OG, TN, VT / TPU jacket967 = 12x22 AWG (same color code as 001) / PVC jacket999 = 12x22 AWG (same color code as 001) / TPE jacket14-Pin000 = 14x22 AWG BN, RD/BU, BK, PK, GN, BU, OG, GY/BN, VT, WH, RD, GY,

    YE, TN / TPE jacket002 = 14x22 AWG (same color code as 000) / TPU jacket755 = 12x24 AWG OG, BK, GN, GY, BN, TN, VT, RD, WH, YE, PK, BU / PVC jacket836 = 10x24 AWG GY, GN, BK, BN, PK, YE, WH, RD, VT, BU / PVC jacket917 = 12x24 AWG RD/BU, GY, GN, BK, GY/PK, BN, PK, YE, WH, RD, VT, BU

    / PVC jacket954 = 10x24 AWG (same color code as 836) / TPE jacket998 = 14x22 AWG (same color code as 000) / PVC jacket19-Pin995 = 19x22 AWG BU, GY/PK, RD/BU, WH/GN, BK, BN/GN, PK, WH/YE, GN, YE/BN,

    BU, OG, GY/BN, VT, WH, RD, GY, YE, TN / PVC jacket996 = 19x22 AWG (same color code as 995) / TPU jacket997 = 19x22 AWG (same color code as 995) / TPE jacket

    Number of Wires / AWG / Color Codes

    * Male connector listed 1st, female connector 2ndExample: BSM BKM 12-001-1

    Insertion Point of Extension Cable 2nd Prefix*

    B S M 12 - 999 - * /S..

    (blank) = nickel plated brassK = nylonV = stainless steel

    HousingMaterial

    (blank) = PVC jacket/S90 = TPU jacket/S101 = flexlife-20, high flex cable

    Varieties

    (blank) = assembled connectorM = straight moldedWM = right angle molded

    Configuration

    K = female connectorS = male connector

    Gender

    Length in Meters

    Part Number Keys are to assist in IDENTIFICATION ONLY. Consult factory for catalog items not identified.

    Extension Examples:

    B S M B K W M 12 - 999 - * /S..

    B S W M B K M 12 - 999 - * /S..

    B S M B K M 12 - 999 - * /S..

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    ve

    rs

    afa

    st

    Receptacle Part Number Key

    B K F D 14 - 12 - * /14.5/NPT

    (blank) = front mountD = rear mount

    Housing Style

    M16 versafast Receptacle

    K = female receptacleS = male receptacle

    Gender

    Designator for Receptacle

    Length in Meters

    5 = 5x18 AWG BN, BU, WH, BU, BK, GY6 = 6x18 AWG BN, BU, WH, BU, BK, GY, PK7 = 7x18 AWG WH, BN, GN, YE, GY, PK, BU8 = 8x18 AWG WH, BN, GN, YE, GY, PK, BU, RD12 = 12x22 AWG BN, BU, WH, GN, YE, GY, PK, RD, BK, OG, TN, VT14 = 14x22 AWG BN, RD/BU, BK, PK, GN, BU, OG, GY/BN, VT, WH, RD, GY, YE, TN19 = 19x22 AWG BN, GY/PK, RD/BU, WH/GN, BK, BN/GN, PK, WH/YE, GN, YE/BN,

    BU, OG, GY/BN, VT, WH, RD, GY, YE, TN

    Number of Wires / AWG / Color Codes

    Part Number Keys are to assist in IDENTIFICATION ONLY. Consult factory for catalog items not identified.

    (blank) = nickel plated brassV = stainless steel

    HousingMaterial

    5 = 56 = 67 = 78 = 8

    12 = 1214 = 1419 = 19PCB = PCB Pins

    Number of Pins

    /14.5/NPT = 1/2-14NPT threads/18.375/NPT = 3/8-18NPT threads/M20 = M20 threads/M18 = M18 thread

    Thread Type

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    Part Number Key is based on the numberconfigurationmolded on the tee body.

    Trunk(2)Trunk(1)

    Drop(3)

    5 = 56 = 67 = 78 = 8

    Number of Pins

    M16 versafast

    B S M / 2BKM 5 - 084 - * - /S..

    (blank) = nickel plated brassK = nylonV = stainless steel

    Coupling Nut Material

    /S = consult factory, special/CS= consult factory, special

    Varieties

    M = straight

    Configuration

    K = female connectorS = male connector

    Trunk(1) Identifier

    Part Number Keys are to assist in IDENTIFICATION ONLY. Consult factory for catalog items not identified.

    2BKM = female trunk(2) and female drop(3)BSM/BKM = male trunk(2) and female drop(3)BSM = male drop (3)BKM/BSM = female trunk(2) and male drop(3)

    Trunk(2) and Drop(3) Identifiers

    (blank) = connector only084 = 5x18 AWG, BN, WH, BU, BK, GY085 = 6x18 AWG, BN, WH, BU, BK, GY, PK086 = 7x18 AWG, WH, BN, GN, YE, GY, PK, BU087 = 8x18 AWG, WH, BN, GN, YE, GY, PK, BU, RD

    AWG / Color Code

    (blank) = connector only* = drop cable*/*/* = trunk(1) cable / trunk(2) cable / drop(3) cable

    Length in Meters

    Note: Only one male connector per tee.

    Tee Examples:B S M / 2 B K M 5 - 084 - *

    Standard Tee Part Number Key

    B S M / B K M / B S M 8

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    ve

    rs

    afa

    st

    h tee Part Number Key is based on the numberconfigurationmolded on the tee body.

    Trunk(2)Trunk(1)

    Drop(3)

    5 = 56 = 67 = 78 = 8

    Number of Pins

    M16 versafast

    BH - B S M / 2BKM 5 - 084 - * - /S..

    (blank) = nickel plated brassK = nylonV = stainless steel

    Coupling Nut Material

    /S = consult factory, special/CS= consult factory, special

    Varieties

    M = straight

    Configuration

    K = female connectorS = male connector

    Trunk(1) Identifier

    Part Number Keys are to assist in IDENTIFICATION ONLY. Consult factory for catalog items not identified.

    2BKM = female trunk(2) and female drop(3) (h)BSM/BKM = male trunk(2) and female drop(3) (h)3BKM = female trunk(2) and female drops(3&4) (H)BSM/2BKM = male trunk(2) and female drops(3&4) (H)

    Trunk(2) and Drop(3&4) Identifiers

    (blank) = connector only084 = 5x18 AWG, BN, WH, BU, BK, GY085 = 6x18 AWG, BN, WH, BU, BK, GY, PK086 = 7x18 AWG, WH, BN, GN, YE, GY, PK, BU087 = 8x18 AWG, WH, BN, GN, YE, GY, PK, BU, RD

    AWG / Color Code

    (blank) = connector only* = drop cable*/*/* = trunk(1) cable / trunk(2) cable /

    drop(3) cable*/*/*/* = trunk(1) cable / trunk(2) cable /

    drop(3) cable / drop(4) cable

    Length in Meters

    Note: Only one male connector per tee.

    Tee Examples:BH - B S M / 3 B K M 5 - 084 - *

    H/h Style Tee Part Number Key

    SH - B S M / B S M / B K M 8

    BH = big HSH = small h

    H/h Style

    H tee Part Number Key is based on the numberconfigurationmolded on the tee body.

    Trunk(2)Trunk(1)

    Drop(4)Drop(3)

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    Connector Style Female Part Number Male Part Number Features Pinout

    BKM 5-084-*BKWM 5-084-*

    BSM 5-084-*BSWM 5-084-*

    PVC Yellow, 5x18 AWG,105C, 300 VAC/VDC, 8 A,7.0 mm OD,Cable #RF51084-*M,5-wire DC application,flexlife

    1. BN2. WH3. BU4. BK5. GY

    BKM 6-085-*BKWM 6-085-*

    BSM 6-085-*BSWM 6-085-*

    PVC Yellow, 6x18 AWG,105C, 300 VAC/VDC, 7 A,7.5 mm OD, Cable#RF51085-*M, 6-wire DCapplication, flexlife

    1. BN2. WH3. BU4. BK5. GY6. PK

    BKM 7-086-*BKWM 7-086-*

    BSM 7-086-*BSWM 7-086-*

    PVC Yellow, 7x18 AWG,105 C, 125 VAC/VDC, 7 A,7.5 mm OD, Cable#RF51086-*M, 7-wire DCapplication, flexlife

    1. WH2. BN3. GN4. YE5. GY6. PK7. BU

    BKM 8-087-*BKWM 8-087-*

    BSM 8-087-*BSWM 8-087-*

    PVC Yellow, 8x18 AWG,105 C, 125 VAC/VDC, 7 A,8.5 mm OD, Cable#RF51087-*M, 8-wire DCapplication, flexlife

    1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD

    * Length in meters. Standard cable lengths are 5 and 10 meters. Consult factory for other lengths.Standard housing and coupling nut material is anodized aluminum.. "BKM.."; "BKMV.." indicates stainless steel and "BKMK.." indicates nylon. See Section N for reelfast cable information.

    IEC IP67 Protection

    5 - 8 Pin Cordsets

    BKM ..

    Female

    Female

    Female

    Female

    BKWM ..

    BSM ..

    Male

    Male

    Male

    Male

    BSWM ..

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    Cordsets

    Connector Style Female Part Number Male Part Number Features Pinout

    BKM 12-001-*BKWM 12-001-*

    BSM 12-001-*BSWM 12-001-*

    TPU Black, 12x22 AWG,90C, 125 VAC/VDC, 4 A,7.6 mm OD, Cable#RF51001-*M, 12-wire DCapplications, flexlife

    A. BNB. BUC. WHD. GNE. YEF. GYG. PKH. RDJ. BKK. OGL. TNM. VT

    BKM 12-967-*BKWM 12-967-*

    BSM 12-967-*BSWM 12-967-*

    PVC Black, 12x22 AWG,105C, 125 VAC/VDC, 4 A, 7.6mm OD, Cable#RF50967-*M, 12-wire DCapplications, flexlife

    BKM 12-999-*/S101BKWM 12-999-*/S101

    BSM 12-999-*/S101BSWM 12-999-*/S101

    TPE Black, 12x22 AWG, 105C,125 VAC/VDC, 4 A, 7.6 mmOD, Cable #RF50999-*M,12-wire DC applications,flexlife-20, High Flex - Over20 million cycles

    * Length in meters. Standard cable lengths are 5 and 10 meters. Consult factory for other lengths.Standard coupling nut material is nickel plated brass.. "BKM.."; "BKMK.." indicates nylon and "BKMV.." indicates stainless steel. See Section N for reelfast cable information.

    For eurofast Junction Boxes andmulti-conductor applications

    IEC IP67 Protection

    12-Pin Cordsets

    BKM ..

    Female

    BKWM ..

    BSM ..

    Male

    BSWM ..

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    Connector Style Female Part Number Male Part Number Features Pinout

    BKM 14-002-*BKWM 14-002-*

    BSM 14-002-*BSWM 14-002-*

    TPU Black, 14x22 AWG,90C, 30 VAC/VDC, 3 A, 7.6mm OD, Cable#RF51002-*M, 14-wire DCapplicationsflexlife

    A. BNC. RD/BUE. BKG. PKJ. GNL. BUM. OGN. GY/BNO. VTP. WHR. RDS. GYT. YEU. TN

    BKM 14-000-*/S101BKWM 14-000-*/S101

    BSM 14-000-*/S101BSWM 14-000-*/S101

    TPE Black, 14x22 AWG, 105C,30 VAC/VDC, 3 A, 7.6 mm OD,Cable #RF51000-*M, 14-wireDC applications, flexlife-20,high flex - over 20 millioncycles

    BKM 14-998-*BKWM 14-998-*

    BSM 14-998-*BSWM 14-998-*

    PVC Black, 14x22 AWG,105C, 30 VAC/VDC, 3 A, 7.6mm OD, Cable#RF50998-*M, 14-wire DCapplications, flexlife

    BKM 14-755-*BKWM 14-755-*

    BSM 14-755-*BSWM 14-755-*

    PVC Black, 12x24 AWG,105C, 30 VAC/VDC, 3 A, 7.0mm OD, Cable#RF50755-*M, 12-wire DCapplications, flexlife

    A. N/CC. OGE. BKG. GNJ. GYL. N/CM. BNN. TNO. VTP. RDR. WHS. YET. PKU. BU

    * Length in meters. Standard cable lengths are 5 and 10 meters. Consult factory for other lengths.Standard coupling nut material is nickel plated brass.. "BKM.."; "BKMK.." indicates nylon and "BKMV.." indicates stainless steel. See Section N for reelfast cable information.

    For picofast Junction Boxes andmulti-conductor applications

    IEC IP67 Protection

    14-Pin Cordsets

    Female

    BKM ..

    BKWM ..

    BSM ..

    Male

    BSWM ..

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    Cordsets

    Connector Style Female Part Number Male Part Number Features Pinout

    BKM 14-836-*BKWM 14-836-*

    BSM 14-836-*BSWM 14-836-*

    PVC Black, 10x24 AWG,105C, 30 VAC/VDC, 3 A, 6.6mm OD, Cable#RF50836-*M, 10-wire DCapplications, junction box,VB 803M(Z)-BS14, flexlife

    A. N/CC. GYE. GNG. BKJ. N/CL. N/CM. BNN. PKO. YEP. WHR. RDS. VTT. N/CU. BUBKM 14-954-*/S101

    BKWM 14-954-*/S101BSM 14-954-*/S101BSWM 14-954-*/S101

    TPE Black, 10x24 AWG, 105C,30 VAC/VDC, 3 A, 7.0 mm OD,Cable #RF50954-*M, 10-wireDC applications, junctionboxVB 803M(Z)-BS14, flexlife-20,high flex - over 20 millioncycles

    BKM 14-917-*BKWM 14-917-*

    BSM 14-917-*BSWM 14-917-*

    PVC Yellow, 12x24 AWG,105C, 30 VAC/VDC, 3 A, 7.0mm OD, Cable#RF50917-*M, 12-wire DCapplications, junction boxes4MBM12-5-BS14 & VB404M(Z)-BS14, flexlife

    A. RD/BUC. GYE. GNG. BKJ. N/CL. GY/PKM. BNN. PKO. YEP. WHR. RDS. VTT. N/CU. BU

    * Length in meters. Standard cable lengths are 5 and 10 meters. Consult factory for other lengths.Standard coupling nut material is nickel plated brass.. "BKM.."; "BKMK.." indicates nylon and "BKMV.." indicates stainless steel. See Section N for reelfast cable information.

    For eurofast /picofast Junction Boxesandmulti-conductor applications

    IEC IP67 Protection

    14-Pin Cordsets

    Female

    BKM ..

    BKWM ..

    BSM ..

    Male

    BSWM ..

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    Connector Style Female Part Number Male Part Number Features Pinout

    BKM 19-873-*BKWM 19-873-*

    BSM 19-873-*BSWM 19-873-*

    PVC Black, 19x26 AWG,105C, 30 VAC/VDC, 3 A,7.1 mm OD, Cable#RF50873-*M,19-wire DC applications,flexlife

    A. RD/BUB. WH/GNC. GYD. BN/GNE. GNF. GN/YEG. BKH. WH/YEI. WH/GYK. GY/BNL. GY/PKM. BNN. PKO. YEP. WHR. RDS. VTT. YE/BNU. BU

    BKM 19-995-*BKWM 19-995-*

    BSM 19-995-*BSWM 19-995-*

    PVC Black, 19x22 AWG,105C, 30 VAC/VDC, 3 A,8.5 mm OD, Cable#RF50995-*M,19-wire DC applications &junction boxVB 804M(Z)-BS19,flexlife

    A. BUB. GY/PKC. RD/BUD. WH/GNE. BKF. BN/GNG. PKH. WH/YEI. GNK. YE/BNL. BNM. OGN. GY/BNO. VTP. WHR. RDS. GYT. YEU. TN

    BKM 19-996-*/S90BKWM 19-996-*/S90

    BSM 19-996-*/S90BSWM 19-996-*/S90

    TPU Black, 19x22 AWG,90C, 30 VAC/VDC, 3 A, 8.5mm OD, Cable#RF50996-*M,19-wire DC applications &junction boxVB 804M(Z)-BS19,Cut/Abrasion Immune

    BKM 19-997-*/S101BKWM 19-997-*/S101

    BSM 19-997-*/S101BSWM 19-997-*/S101

    TPE Black, 19x22 AWG,105C, 30 VAC/VDC, 3 A,8.5 mm OD, Cable#RF50997-*M,19-wire DC applications &junction boxVB 804M(Z)-BS19,Flexlife-20, High Flex -Over 20 million cycles

    * Length in meters. Standard cable lengths are 5 and 10 meters. Consult factory for other lengths.Standard coupling nut material is nickel plated brass.. "BKM.."; "BKMK.." indicates nylon and "BKMV.." indicates stainless steel. See Section N for reelfast cable information.

    19-Pin Cordsets

    Female

    For picofast Junction Boxes andmulti-conductor applications

    IEC IP67 Protection

    BKM ..

    BKWM ..

    BSM ..

    Male

    BSWM ..

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    Cordsets

    Connector Style Female Part Number Male Part Number Features Pinout

    WD-BKMV 5-1573-*WD-BKWMV 5-1573-*

    WD-BSMV 5-1573-*WD-BSWMV 5-1573-*

    PP White, 5x18 AWG, 105C, 300V, 8 A, 6.5 mm OD, Cable#RF51573-*M, high chemicalsolvent resistance, high tensilestrength

    1. BN2. WH3. BU4. BK5. GY

    WD-BKMV 6-1575-*WD-BKWMV 6-1575-*

    WD-BSMV 6-1575-*WD-BSWMV 6-1575-*

    PP White, 6x18 AWG, 105C, 300V, 7 A, 7.0 mm OD, Cable#RF51575-*M, high chemicalsolvent resistance, high tensilestrength

    1. BN2. WH3. BU4. BK5. GY6. PK

    WD-BKMV 8-1574-*WD-BKWMV 8-1574-*

    WD-BSMV 8-1574-*WD-BSWMV 8-1574-*

    PP White, 8x18 AWG, 105C, 125V, 7 A, 7.6 mm OD, Cable#RF51574-*M, high chemicalsolvent resistance, high tensilestrength

    1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD

    * Length in meters. Standard cable lengths are 2, 4, 5, 6, 8 and 10 meters. Consult factory for other lengths.Standard coupling nut material is stainless steel.

    WD-BKMV ..

    (Cable diameter up toand including 7.5 mm)

    IEC IP67 Protection Polypropylene contact holder, mold

    material and cable jacket

    5 - 8-PinWashdown Cordsets

    Female

    Female

    Female

    WD-BKWMV ..

    (Cable diameter up toand including 7.5 mm)

    WD-BSWMV ..

    (Cable diameter over 7.5 mm)

    WD-BSMV ..

    (Cable diameter up toand including 7.5 mm)

    Male

    Male

    Male

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    M16 Receptacle Selection Guide

    Mounting Style Image Panel Thread Types Page

    Front Mount

    M18 G15

    M20 G17

    1/2-14 NPT G19

    3/8-18 NPT G21

    Rear Mount M18 G25

    PCBMount PCB G27

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    Receptacles

    Housing Style Female Part Number Male Part Number Features Pinout

    BKF 5-5-* BSF 5-5-*

    5x20 AWG, 105C, 300VAC/VDC, 8A, 5-Wire DCApplication

    1. BN2. WH3. BU4. BK5. GY

    BKF 6-6-* BSF 6-6-*

    6x20 AWG, 105C, 300VAC/VDC, 7A, 6-Wire DCApplication

    1. BN2. WH3. BU4. BK5. GY6. PK

    BKF 7-7-* BSF 7-7-*

    7x20 AWG, 105C, 125VAC/VDC, 7A, 7-Wire DCApplication

    1. WH2. BN3. GN4. YE5. GY6. PK7. BU

    BKF 8-8-* BSF 8-8-*8x20 AWG, 105C, 125VAC/VDC, 7A, 8-Wire DCApplication

    1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD

    * Length in meters. Standard lead length is 0.5 Meter. Consult factory for other lengths.Standard housing material is nickel plated brass.To specify PVC jacketed cable, add "/S717" to the end of the part number.

    5 - 8 Pin Receptacles, Front Mount

    IEC IP67 Protection

    Male

    Male

    Male

    Male

    Female

    Female

    Female

    Female

    BSF .. (5-8 pin)

    Typical panel cutout is 18 x 17mm.

    BKF ..(5-8 pin)

    Typical panel cutout is 18 x 17mm.

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    12, 14 and 19-Pin Receptacles, Front Mount

    Housing Style Female Part Number Male Part Number Features Pinout

    BKF 12-12-* BSF 12-12-*

    12x24 AWG,105C, 125VAC/VDC, 4 A,mates with 12-pinconnectors,12 conductors

    A. BNB. BUC. WHD. GNE. YEF. GYG. PKH. RDJ. BKK. OGL. TNM. VT

    BKF 14-10-* BSF 14-10-*

    10x24 AWG,105C, 30VAC/VDC, 3 A,mates with 14-pinconnectors,10 conductors

    C. GYE. GNG. BKM. BNN. PKO. YEP. WHR. RDS. VTU. BU

    BKF 14-12-* BSF 14-12-*

    12x24 AWG,105C, 30VAC/VDC, 3 A,mates with 14-pinconnectors,12 conductors

    C. OGE. BKG. GNJ. GYM. BNN. TN

    O. VTP. RDR. WHS. YET. PKU. BU

    BKF 14-14-* BSF 14-14-*

    14x24 AWG,105C, 30VAC/VDC, 3 A,mates with 14-pinconnectors,14 conductors

    A. BNC. RD/BUE. BKG. PKJ. GNL. BUM. OG

    N. GY/BNO. VTP. WHR. RDS. GYT. YEU. TN

    BKF 19-19-* BSF 19-19-*

    19x24 AWG,105C, 30VAC/VDC, 3 A,mates with 19-pinconnectors,19 conductors

    A. BUB. GY/PKC. RD/BUD. WH/GNE. BKF. BN/GNG. PKH. WH/YEI. GNK. YE/BN

    L. BNM.OGN. GY/BNO. VTP. WHR. RDS. GYT. YEU. TN

    * Length in meters. Standard lead length is 0.5 Meter. Consult factory for other lengths.Standard housing material is nickel plated brass.To specify PVC jacketed cable, add "/S717" to the end of the part number.

    Male

    Male

    For use with Junction Box Home RunCables

    IEC IP67 Protection

    Male

    Female

    Female

    Female

    BSF .. (12, 14, 19 pin)

    Typical panel cutout is 18 x 17mm.

    BKF ..(12, 14, 19 pin)

    Typical panel cutout is 18 x 17mm.

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    Receptacles

    5 - 8 Pin Receptacles, Front Mount, M18 Threads

    IEC IP67 Protection

    Housing Style Female Part Number Male Part Number Features Pinout

    BKF 5-5-*/M18 BSF 5-5-*/M18

    5x18 AWG, 105C, 300VAC/VDC, 8 A, 5-wire DCapplication

    1. BN2. WH3. BU4. BK5. GY

    BKF 6-6-*/M18 BSF 6-6-*/M18

    6x18 AWG, 105C, 300VAC/VDC, 7 A, 6-wire DCapplication

    1. BN2. WH3. BU4. BK5. GY6. PK

    BKF 7-7-*/M18 BSF 7-7-*/M18

    7x18 AWG, 105C, 125VAC/VDC, 7 A, 7-wire DCapplication

    1. WH2. BN3. GN4. YE5. GY6. PK7. BU

    BKF 8-8-*/M18 BSF 8-8-*/M188x18 AWG, 105C, 125VAC/VDC, 7 A, 8-wire DCapplication

    1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD

    * Length in meters. Standard lead length is 0.5 meter. Consult factory for other lengths.Standard housing material is nickel plated brass "BSF.." and "BSFV.." indicates stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.

    Male

    Male

    BSF .. M18 (5-8 pin)

    Typical panel cutout is 18.6 mm.

    Female

    Female

    Female

    Female

    BKF .. M18 (5-8 pin)

    Typical panel cutout is 18.6 mm.

    Male

    Male

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    For use with Junction Box HomeRunCables

    IEC IP67 Protection

    12, 14 and 19-Pin Receptacles, Front Mount, M18 Threads

    Housing Style Female Part Number Male Part Number Features Pinout

    BKF 12-12-*/M18 BSF 12-12-*/M18

    12x22 AWG, 105C,125 VAC/VDC, 4 A,mates with 12-pinconnectors,12 conductors

    A. BNB. BUC. WHD. GNE. YEF. GYG. PKH. RDJ. BKK. OGL. TNM. VT

    BKF 14-10-*/M18 BSF 14-10-*/M18

    10x22 AWG, 105C,30 VAC/VDC, 3 A,mates with 14-pinconnectors,10 conductors

    C. GYE. GNG. BKM. BNN. PK

    O. YEP. WHR. RDS. VTU. BU

    BKF 14-12-*/M18 BSF 14-12-*/M18

    12x22 AWG105C30 VAC/VDC, 3 Amates with 14-pinconnectors,12 conductors

    C. OGE. BKG. GNJ. GYM. BNN. TN

    O. VTP. RDR. WHS. YET. PKU. BU

    BKF 14-14-*/M18 BSF 14-14-*/M18

    14x22 AWG, 105C,30 VAC/VDC, 3 A,mates with 14-pinconnectors,14 conductors

    A. BNC. RD/BUE. BKG. PKJ. GNL. BUM. OG

    N. GY/BNO. VTP. WHR. RDS. GYT. YEU. TN

    BKF 19-19-*/M18 BSF 19-19-*/M18

    19x22 AWG, 105C,30 VAC/VDC, 3 A,mates with 19-pinconnectors,19 conductors

    A. BUB. GY/PKC. RD/BUD. WH/GNE. BKF. BN/GNG. PKH. WH/YEI. GNK. YE/BN

    L. BNM.OGN. GY/BNO. VTP. WHR. RDS. GYT. YEU. TN

    * Length in meters. Standard lead length is 0.5 meter. Consult factory for other lengths.Standard housing material is nickel plated brass "BSF.." and "BSFV.." indicates stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.

    Male

    Male

    Male

    Female

    Female

    Female

    BKF .. M18 (12, 14, 19 pin)

    Typical panel cutout is 18.6 mm.

    BSF .. M18 (12, 14, 19 pin)

    Typical panel cutout is 18.6 mm.

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    Receptacles

    5 - 8 Pin Receptacles, Front Mount, M20 Threads

    IEC IP67 Protection

    Housing Style Female Part Number Male Part Number Features Pinout

    BKF 5-5-*/M20 BSF 5-5-*/M20

    5x18 AWG, 105C, 300VAC/VDC, 8 A, 5-Wire DCapplications

    1. BN2. WH3. BU4. BK5. GY

    BKF 6-6-*/M20 BSF 6-6-*/M20

    6x18 AWG, 105C, 300VAC/VDC, 7 A, 6-Wire DCapplications

    1. BN2. WH3. BU4. BK5. GY6. PK

    BKF 7-7-*/M20 BSF 7-7-*/M20

    7x18 AWG, 105C, 125VAC/VDC, 7 A, 7-Wire DCapplications

    1. WH2. BN3. GN4. YE5. GY6. PK7. BU

    BKF 8-8-*/M20 BSF 8-8-*/M208x18 AWG, 105C, 125VAC/VDC, 7A, 8-Wire DCapplications

    1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD

    * Length in meters. Standard lead length is 0.5 meter. Consult factory for other lengths.Standard housing material is nickel plated brass "BSF.."and "BSFV.." indicates stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.

    Male

    Male

    BSF ..M20 (5-8 pin)

    Typical panel cutout is 20.4 mm.

    Male

    Male

    Female

    Female

    Female

    Female

    BKF ..M20 (5-8 pin)

    Typical panel cutout is 18.6 mm.

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    12, 14 and 19-Pin Receptacles, Front Mount, M20 Threads

    Housing Style Female Part Number Male Part Number Features Pinout

    BKF 12-12-*/M20 BSF 12-12-*/M20

    12x22 AWG,105C, 125VAC/VDC, 4 A,mates with 12-pinconnectors,12 conductors

    A. BNB. BUC. WHD. GNE. YEF. GY

    G. PKH. RDJ. BKK. OGL. TNM.VT

    BKF 14-10-*/M20 BSF 14-10-*/M20

    10x22 AWG,105C, 30VAC/VDC, 3 A,mates with 14-pinconnectors,10 conductors

    C. GYE. GNG. BKM. BNN. PK

    O. YEP. WHR. RDS. VTU. BU

    BKF 14-12-*/M20 BSF 14-12-*/M20

    12x22 AWG,105C, 30VAC/VDC, 3 A,mates with 14-pinconnectors,12 conductors

    C. OGE. BKG. GNJ. GYM. BNN. TN

    O. VTP. RDR. WHS. YET. PKU. BU

    BKF 14-14-*/M20 BSF 14-14-*/M20

    14x22 AWG,105C, 30VAC/VDC, 3 A,mates with 14-pinconnectors,14 conductors

    A. BNC. RD/BUE. BKG. PKJ. GNL. BUM. OG

    N. GY/BNO. VTP. WHR. RDS. GYT. YEU. TN

    BKF 19-19-*/M20 BSF 19-19-*/M20

    19x22 AWG,105C, 30VAC/VDC, 3 A,mates with 19-pinconnectors,19 conductors

    A. BUB. GY/PKC. RD/BUD. WH/GNE. BKF. BN/GNG. PKH. WH/YEI. GNK. YE/BN

    L. BNM.OGN. GY/BNO. VTP. WHR. RDS. GYT. YEU. TN

    *Length in meters. Standard lead length is 0.5 meter. Consult factory for other lengths.Standard housing material is nickel plated brass "BSF.." and "BSFV.." indicates stainless steel.To specify PVC jacketed cable, add /S717" to the end of the part number.

    Male

    Male

    Male

    For use with Junction BoxHomeRun Cables

    IEC IP67 Protection

    BSF ..M20 (12, 14, 19 pin)

    Typical panel cutout is 20.4 mm.

    Female

    Female

    Female

    BKF ..M20 (12, 14, 19 pin)

    Typical panel cutout is 18.6 mm.

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    Receptacles

    5 - 8 Pin Receptacles, Front Mount, 1/2-14 NPT Threads

    IEC IP67 Protection

    Housing Style Female Part Number Male Part Number Features Pinout

    BKF 5-5-*/14.5/NPT BSF 5-5-*/14.5/NPT

    5x18 AWG, 105C, 300VAC/VDC, 8 A, 5-Wire DCapplications

    1. BN2. WH3. BU4. BK5. GY

    BKF 6-6-*/14.5/NPT BSF 6-6-*/14.5/NPT

    6x18 AWG, 105C, 300VAC/VDC, 7 A, 6-Wire DCapplications

    1. BN2. WH3. BU4. BK5. GY6. PK

    BKF 7-7-*/14.5/NPT BSF 7-7-*/14.5/NPT

    7x18 AWG, 105C, 125VAC/VDC, 7 A, 7-Wire DCapplications

    1. WH2. BN3. GN4. YE5. GY6. PK7. BU

    BKF 8-8-*/14.5/NPT BSF 8-8-*/14.5/NPT8x18 AWG, 105C, 125VAC/VDC, 7A, 8-Wire DCapplications

    1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD

    * Length in meters. Standard lead length is 0.5 meter. Consult factory for other lengths.Standard housing material is nickel plated brass "BSF.." and "BSFV.." indicates stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.

    Male

    Male

    Male

    Male

    BSF ..1/2-14 NPT (5-8 pin)

    Typical panel cutout is 22.5 mm.

    Female

    Female

    Female

    Female

    BKF ..1/2-14 NPT (5-8 pin)

    Typical panel cutout is 17.5 mm.

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    12, 14 and 19-Pin Receptacles, Front Mount, 1/2-14 NPT Threads

    Housing Style Female Part Number Male Part Number Features Pinout

    BKF 12-12-*/14.5/NPT BSF 12-12-*/14.5/NPT

    12x22 AWG,105C, 125VAC/VDC, 4 A,mates with12-pinconnectors,12 conductors

    A. BNB. BUC. WHD. GNE. YEF. GY

    G. PKH. RDJ. BKK. OGL. TNM.VT

    BKF 14-10-*/14.5/NPT BSF 14-10-*/14.5/NPT

    10x22 AWG,105C, 30VAC/VDC, 3 A,mates with14-pinconnectors,10 conductors

    C. GYE. GNG. BKM. BNN. PK

    O. YEP. WHR. RDS. VTU. BU

    BKF 14-12-*/14.5/NPT BSF 14-12-*/14.5/NPT

    12x22 AWG,105C, 30VAC/VDC, 3 A,mates with14-pinconnectors,12 conductors

    C. OGE. BKG. GNJ. GYM. BNN. TN

    O. VTP. RDR. WHS. YET. PKU. BU

    BKF 14-14-*/14.5/NPT BSF 14-14-*/14.5/NPT

    14x22 AWG,105C, 30VAC/VDC, 3 A,mates with14-pinconnectors,14 conductors

    A. BNC. RD/BUE. BKG. PKJ. GNL. BUM. OG

    N. GY/BNO. VTP. WHR. RDS. GYT. YEU. TN

    BKF 19-19-*/14.5/NPT BSF 19-19-*/14.5/NPT

    19x22 AWG,105C, 30VAC/VDC, 3 A,mates with19-pinconnectors,19 conductors

    A. BUB. GY/PKC. RD/BUD. WH/GNE. BKF. BN/GNG. PKH. WH/YEI. GNK. YE/BN

    L. BNM.OGN. GY/BNO. VTP. WHR. RDS. GYT. YEU. TN

    * Length in meters. Standard lead length is 0.5 meter. Consult factory for other lengths.Standard housing material is nickel plated brass "BSF.." and "BSFV.." indicates stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.

    Male

    Male

    Male

    For use with Junction BoxHomeRun Cables

    IEC IP67 Protection

    BSF ..1/2-14 NPT (12, 14, 19 pin)

    Typical panel cutout is 22.5 mm.

    Female

    Female

    Female

    BKF ..1/2-14 NPT (12, 14, 19 pin)

    Typical panel cutout is 22.5 mm.

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    Receptacles

    5 - 8 Pin Receptacles, Front Mount, 3/8-18 NPT Threads

    IEC IP67 Protection

    Housing Style Female Part Number Male Part Number Features Pinout

    BKF 5-5-*/18.375/NPT BSF 5-5-*/18.375/NPT

    5x18 AWG, 105C, 300VAC/VDC, 8 A, 5-Wire DCapplications

    1. BN2. WH3. BU4. BK5. GY

    BKF 6-6-*/18.375/NPT BSF 6-6-*/18.375/NPT

    6x18 AWG, 105C, 300VAC/VDC, 7 A, 6-Wire DCapplications

    1. BN2. WH3. BU4. BK5. GY6. PK

    BKF 7-7-*/18.375/NPT BSF 7-7-*/18.375/NPT

    7x18 AWG, 105C, 125VAC/VDC, 7 A, 7-Wire DCapplications

    1. WH2. BN3. GN4. YE5. GY6. PK7. BU

    BKF 8-8-*/18.375/NPT BSF 8-8-*/18.375/NPT8x18 AWG, 105C, 125VAC/VDC, 7A, 8-Wire DCapplications

    1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD

    * Length in meters. Standard lead length is 0.5 meter. Consult factory for other lengths.Standard housing material is nickel plated brass "BSF..".To specify PVC jacketed cable, add "/S717" to the end of the part number.

    Male

    Male

    Male

    Male

    Female

    Female

    Female

    Female

    BKF ..3/8-18 NPT (5-8 pin)

    Typical panel cutout is 17.5 mm.

    BSF ..3/8-18 NPT (5-8 pin)

    Typical panel cutout is 17.5 mm.

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    12, 14 and 19-Pin Receptacles, Front Mount, 3/8-18 NPT Threads

    Housing Style Female Part Number Male Part Number Features Pinout

    BKF 12-12-*/18.375/NPT BSF 12-12-*/18.375/NPT

    12x22 AWG, 105C,125 VAC/VDC, 4 A,mates with 12-pinconnectors,12 conductors

    A. BNB. BUC. WHD. GNE. YEF. GY

    G. PKH. RDJ. BKK. OGL. TNM.VT

    BKF 14-10-*/18.375/NPT BSF 14-10-*/18.375/NPT

    10x22 AWG, 105C,30 VAC/VDC, 3 A,mates with 14-pinconnectors,10 conductors

    C. GYE. GNG. BKM. BNN. PK

    O. YEP. WHR. RDS. VTU. BU

    BKF 14-12-*/18.375/NPT BSF 14-12-*/18.375/NPT

    12x22 AWG, 105C,30 VAC/VDC, 3 A,mates with 14-pinconnectors,12 conductors

    C. OGE. BKG. GNJ. GYM. BNN. TN

    O. VTP. RDR. WHS. YET. PKU. BU

    BKF 14-14-*/18.375/NPT BSF 14-14-*/18.375/NPT

    14x22 AWG, 105C,30 VAC/VDC, 3 A,mates with 14-pinconnectors,14 conductors

    A. BNC. RD/BUE. BKG. PKJ. GNL. BUM. OG

    N. GY/BNO. VTP. WHR. RDS. GYT. YEU. TN

    BKF 19-19-*/18.375/NPT BSF 19-19-*/18.375/NPT

    19x22 AWG, 105C,30 VAC/VDC, 3 A,mates with 19-pinconnectors,19 conductors

    A. BUB. GY/PKC. RD/BUD. WH/GNE. BKF. BN/GNG. PKH. WH/YEI. GNK. YE/BN

    L. BNM.OGN. GY/BNO. VTP. WHR. RDS. GYT. YEU. TN

    * Length in meters. Standard lead length is 0.5 meter. Consult factory for other lengths.Standard housing material is nickel plated brass "BSF.."l.To specify PVC jacketed cable, add "/S717" to the end of the part number.

    Male

    Male

    Male

    For use with Junction BoxHomeRun Cables

    IEC IP67 Protection

    Female

    Female

    FemaleBSF ..3/8-18 NPT (12, 14, 19 pin)

    Typical panel cutout is 17.5 mm.

    BKF ..3/8-18 NPT (12, 14, 19 pin)

    Typical panel cutout is 17.5 mm.

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    Receptacles

    Housing Style Female Part Number Male Part Number Features Pinout

    BKFD 5-5-* BSFD 5-5-*

    5x20 AWG, 105C, 300VAC/VDC, 8A, 5-Wire DCapplication

    1. BN2. WH3. BU4. BK5. GY

    BKFD 6-6-* BSFD 6-6-*

    6x20 AWG, 105C, 300VAC/VDC, 7A, 6-Wire DCapplication

    1. BN2. WH3. BU4. BK5. GY6. PK

    BKFD 7-7-* BSFD 7-7-*

    7x20 AWG, 105C, 125VAC/VDC, 7A, 7-Wire DCapplication

    1. WH2. BN3. GN4. YE5. GY6. PK7. BU

    BKFD 8-8-* BSFD 8-8-*8x20 AWG, 105C, 125VAC/VDC, 7A, 8-Wire DCapplication

    1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD

    * Length in meters. Standard lead lengths is 0.5 meter. Consult factory for other lengths.Standard housing material is nickel plated brass.To specify PVC jacketed cable, add "/S717" to the end of the part number.

    5 - 8Wire Receptacles, Rear Mount

    IEC IP67 Protection

    BKFD .. (5-8 pin)

    Typical panel cutout is 18 x 17mm.

    Male

    Male

    Male

    Male

    Female

    Female

    Female

    Female

    BSFD .. (5-8, 12-19 pin)

    Typical panel cutout is 18 x 17mm.

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    Housing Style Female Part Number Male Part Number Features Pinout

    BKFD 12-12-* BSFD 12-12-*

    12x24 AWG,105C, 125VAC/VDC, 4 A,mates with 12-pinconnectors,12conductors

    A. BNB. BUC. WHD. GNE. YEF. GY

    G. PKH. RDJ. BKK. OGL. TNM.VT

    BKFD 14-10-* BSFD 14-10-*

    10x24 AWG,105C, 30VAC/VDC, 3 A,mates with 14-pinconnectors,10conductors

    C. GYE. GNG. BKM. BNN. PK

    O. YEP. WHR. RDS. VTU. BU

    BKFD 14-12-* BSFD 14-12-*

    12x24 AWG,105C, 30VAC/VDC, 3 A,mates with 14-pinconnectors,12conductors

    C. OGE. BKG. GNJ. GYM. BNN. TN

    O. VTP. RDR. WHS. YET. PKU. BU

    BKFD 14-14-* BSFD 14-14-*

    14x24 AWG,105C, 30VAC/VDC, 3 A,mates with 14-pinconnectors,14 conductors

    A. BNC. RD/BUE. BKG. PKJ. GNL. BUM. OG

    N. GY/BNO. VTP. WHR. RDS. GYT. YEU. TN

    BKFD 19-19-* BSFD 19-19-*

    19x24 AWG,105C, 30VAC/VDC, 3 A,mates with 19-pinconnectors,19 conductors

    A. BUB. GY/PKC. RD/BUD. WH/GNE. BKF. BN/GNG. PKH. WH/YEI. GNK. YE/BN

    L. BNM.OGN. GY/BNO. VTP. WHR. RDS. GYT. YEU. TN

    * Length in meters. Standard lead lengths is 0.5 meter. Consult factory for other lengths.Standard housing material is nickel plated brass.To specify PVC jacketed cable, add "/S717" to the end of the part number.

    12, 14 and 19-Pin Receptacles, Rear Mount

    For use with Junction Box Home RunCables

    IEC IP67 Protection

    Male

    Male

    Male

    Female

    Female

    Female

    BSFD .. (12, 14, 19 pin)

    Typical panel cutout is 18 x 17mm.

    BKFD ..(12, 14, 19 pin)

    Typical panel cutout is 18 x 17mm.

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    Receptacles

    5 - 8 Pin Receptacles, Rear Mount, M18 Threads

    IEC IP67 Protection

    Housing Style Female Part Number Male Part Number Features Pinout

    BKFD 5-5-*/M18 BSFD 5-5-*/M18

    5x18 AWG, 105C, 300VAC/VDC, 8 A, 5-Wire DCapplications

    1. BN2. WH3. BU4. BK5. GY

    BKFD 6-6-*/M18 BSFD 6-6-*/M18

    6x18 AWG, 105C, 300VAC/VDC, 7 A, 6-Wire DCapplications

    1. BN2. WH3. BU4. BK5. GY6. PK

    BKFD 7-7-*/M18 BSFD 7-7-*/M18

    7x18 AWG, 105C, 125VAC/VDC, 7 A, 7-Wire DCapplications

    1. WH2. BN3. GN4. YE5. GY6. PK7. BU

    BKFD 8-8-*/M18 BSFD 8-8-*/M188x18 AWG, 105C, 125VAC/VDC, 7A, 8-Wire DCapplications

    1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD

    *Length in meters. Standard lead length is 0.5 meter. Consult factory for other lengths.Standard housing material is nickel plated brass. "BSFDV.." indicates stainless steel.To specify PVC jacketed cable, add /S717" to the end of the part number.

    Male

    Male

    Male

    Male

    Female

    Female

    Female

    Female

    BSFD.. M18 (5-8 pin)

    Typical panel cutout is 18.6 mm.

    BKFD .. M18 (5-8 pin)

    Typical panel cutout is 18.6 mm.

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    IEC IP67 Protection

    12, 14 and 19-Pin Receptacles, Rear Mount, M18 Threads

    Housing Style Female Part Number Male Part Number Features Pinout

    BKFD 12-12-*/M18 BSFD 12-12-*/M18

    12x22 AWG, 105C,125 VAC/VDC, 4 A,mates with 12-pinconnectors,12 conductors

    A. BNB. BUC. WHD. GNE. YEF. GY

    G. PKH. RDJ. BKK. OGL. TNM.VT

    BKFD 14-10-*/M18 BSFD 14-10-*/M18

    10x22 AWG, 105C,30 VAC/VDC, 3 A,mates with 14-pinconnectors,10conductors

    C. GYE. GNG. BKM. BNN. PK

    O. YEP. WHR. RDS. VTU. BU

    BKFD 14-12-*/M18 BSFD 14-12-*/M18

    12x22 AWG, 105C,30 VAC/VDC, 3 A,mates with 14-pinconnectors,12conductors

    C. OGE. BKG. GNJ. GYM. BNN. TN

    O. VTP. RDR. WHS. YET. PKU. BU

    BKFD 14-14-*/M18 BSFD 14-14-*/M18

    14x22 AWG, 105C,30 VAC/VDC, 3 A,mates with 14-pinconnectors,14conductors

    A. BNC. RD/BUE. BKG. PKJ. GNL. BUM. OG

    N. GY/BNO. VTP. WHR. RDS. GYT. YEU. TN

    BKFD 19-19-*/M18 BSFD 19-19-*/M18

    19x22 AWG, 105C,30 VAC/VDC, 3 A,mates with 19-pinconnectors,19 conductors

    A. BUB. GY/PKC. RD/BUD. WH/GNE. BKF. BN/GNG. PKH. WH/YEI. GNK. YE/BN

    L. BNM.OGN. GY/BNO. VTP. WHR. RDS. GYT. YEU. TN

    *Length in meters. Standard lead length is 0.5 meter. Consult factory for other lengths.Standard housing material is nickel plated brass. "BSFDV.." indicates stainless steel.To specify PVC jacketed cable, add /S717" to the end of the part number.

    BSFD.. M18 (12, 14, 19 pin)

    Typical panel cutout is 18.6 mm.

    BKFD .. M18 (12, 14, 19 pin)

    Typical panel cutout is 18.6 mm.

    Male

    Female

    Male

    Female

    Male

    Female

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    Receptacles

    Housing Style Female Part Number Male Part Number Features Pinout

    BKFD 5-PCB BSFD 5-PCB Nickel plated brass, 5-pin PCB pins,105C, 60 V, 5 A, M18 x .75 threads,mates with 5-pin cordsets

    BKFD 6-PCB BSFD 6-PCB

    Nickel plated brass, 5-pin PCB pins,105C, 250 V, 5 A, M18 x .75 threads,mates with 6-pin cordsets

    BKFD 7-PCB BSFD 7-PCB

    Nickel plated brass, 5-pin PCB pins,105C, 60 V, 5 A, M18 x .75 threads,mates with 7-pin cordsets

    BKFD 8-PCB BSFD 8-PCBNickel plated brass, 5-pin PCB pins,105C, 60 V, 5 A, M18 x .75 threads,mates with 8-pin cordsets

    Locknuts and O-rings Included Easy Keyway Orientation IEC IP67 Protection

    5 - 8 Pin Receptacles, Rear Mount, PCB Pins

    5-Pin PCB Layout 7-Pin PCB Layout6-Pin PCB Layout 8-Pin PCB Layout

    Male

    Male

    Male

    Male

    Female

    Female

    Female

    Female

    BSFD ..PCB (5-8 pin)

    BKFD ..PCB (5-8 pin)

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    Housing Style Female Part Number Male Part Number Features Pinout

    BKFD 12-PCB BSFD 12-PCB

    Nickel plated brass, 12-pin PCB pins,105C, 60 V, 3 A, M18x.75 threads,mates with 12-pin cordsets

    BKFD 14-PCB BSFD 14-PCBNickel plated brass,14-pin PCB pins,105C, 60 V, 3 A, M18x.75 threads,mates with 14-pin cordsets

    BKFD 19-PCB BSFD 19-PCBNickel plated brass, 19-pin PCB pins,105C, 60 V, 3 A, M18x.75 threads,mates with 19-pin cordsets

    12, 14 and 19-Pin Receptacles, Rear Mount, PCB Pins

    Locknuts and O-rings Included Easy Keyway Orientation IEC IP67 Protection

    19-Pin PCB Layout12-Pin PCB Layout 14-Pin PCB Layout

    Male

    Female

    Male

    Female

    Male

    FemaleBSFD ..PCB (12, 14, 19 pin)

    BKFD ..PCB (12, 14, 19 pin)

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    Receptacles

    12, 14 and 19-Pin Receptacles, Solder Cups, Front and Rear Mount

    Facilitates Field Replacements

    Housing Style Female Part Number Male Part Number Features Pinout

    BKF 12 BSF 12

    Nickel plated brass, solder cup,accepts up to 12x24 AWG conductors,95C, 125 V, 4 A, mates with picofastjunction boxes, front mount

    BKFD 12 BSFD 12

    Nickel plated brass, solder cup,accepts up to 12x24 AWG conductors,95 C, 125 V, 3 A, mates with picofastjunction boxes, rear mount

    BKF 14 BSF 14

    Nickel plated brass, solder cup,accepts up to 14x24 AWG conductors,95C, 125 V, 3 A, mates with picofastjunction boxes, front mount

    BKFD 14 BSFD 14

    Nickel plated brass, solder cup,accepts up to 14x24 AWG conductors,95C, 125 V, 3 A, mates with picofastjunction boxes, rear mount

    BKF 19 BSF 19

    Nickel plated brass, solder cup,accepts up to 19x24 AWG conductors,95C, 125 V, 3 A, mates with picofastjunction boxes, front mount

    BKFD 19 BSFD 19

    Nickel plated brass, solder cup,accepts up to 19x24 AWG conductors,95C, 30 V, 3 A, mates with picofastjunction boxes, rear mount

    BKFD (12, 14, 19 pin)

    BKF (12, 14, 19 pin)

    BSFD (12, 14, 19 pin)

    BSF (12, 14, 19 pin)

    Male

    Female

    Male

    Female

    Male

    Female

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    Parallel Wiring Simplifies Wiring Installations ToughMolded Thermoplastic Polyurethane Body IEC IP67 Protection 1Male and 2 Female Connectors

    Female Male

    5-Pin 6-Pin 7-Pin 8-Pin 5-Pin 6-Pin 7-Pin 8-Pin

    Pinouts

    5 Conductor 6 Conductor 7 Conductor 8 Conductor

    BSM/2BKM ..

    Tees

    Dimensions

    BSM/2BKM -XXX-*

    Part Number Features

    BSM/2BKM 5 5 conductor, integral connector drop, 125 V, 8 A, 105C

    BSM/2BKM 5-084-* 5 conductor, cable drop, PVC yellow, 5x18 AWG, 7.0 mm OD, 125 V, 8 A, 105C

    BSM/2BKM 6 6 conductor, integral connector drop, 125 V, 7 A, 105C

    BSM/2BKM 6-085-* 6 conductor, cable drop, PVC yellow, 6x18 AWG, 7.5 mm OD, 125 V, 7 A, 105C

    BSM/2BKM 7 7 conductor, integral connector drop, 125 V, 7 A, 105C

    BSM/2BKM 7-086-* 7 conductor, cable drop, PVC yellow, 7x18 AWG, 8.1 mm OD, 125 V, 7 A, 105C

    BSM/2BKM 8 8 conductor, integral connector drop, 125 V, 7 A, 105C

    BSM/2BKM 8-087-* 8 conductor, cable drop, PVC yellow, 8x18 AWG, 8.5 mm OD, 125 V, 7 A, 105C

    * = Cable length in meters

    Wiring Diagrams = Number of pins

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    Tees

    Parallel Wiring Simplifies Wiring Installations ToughMolded Thermoplastic Polyurethane Body IEC IP67 Protection 1Male and 2 Female Connectors

    h-Style Tees, Trunk #1Male

    Part Number Features

    SH-BSM/2BKM 5 5 conductor, integral connector drop, 125 V, 8 A, 105C

    SH-BSM/2BKM 5-084-* 5 conductor, cable drop, PVC yellow, 5x18 AWG, 7.0 mm OD, 125 V, 8 A, 105C

    SH-BSM/2BKM 6 6 conductor, integral connector drop, 125 V, 7 A, 105C

    SH-BSM/2BKM 6-085-* 6 conductor, cable drop, PVC yellow, 6x18 AWG, 7.5 mm OD, 125 V, 7 A, 105C

    SH-BSM/2BKM 7 7 conductor, integral connector drop, 125 V, 7 A, 105C

    SH-BSM/2BKM 7-086-* 7 conductor, cable drop, PVC yellow, 7x18 AWG, 8.1 mm OD, 125 V, 7 A, 105C

    SH-BSM/2BKM 8 8 conductor, integral connector drop, 125 V, 7 A, 105C

    SH-BSM/2BKM 8-087-* 8 conductor, cable drop, PVC yellow, 8x18 AWG, 8.5 mm OD, 125 V, 7 A, 105C

    * = Cable length in meters

    SH-BSM/2BKM *

    Wiring Diagrams5 Conductor 6 Conductor 7 Conductor 8 Conductor

    Female Male

    5-Pin 6-Pin 7-Pin 8-Pin 5-Pin 6-Pin 7-Pin 8-Pin

    Pinouts

    SH-BSM/2BKM -XXX-*

    Dimensions

    = Number of pins

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    Female Male

    5-Pin 6-Pin 7-Pin 8-Pin 5-Pin 6-Pin 7-Pin 8-Pin

    Pinouts

    Parallel Wiring Simplifies Wiring Installations ToughMolded Thermoplastic Polyurethane Body IEC IP67 Protection 2 Female and 1Male Connectors

    h-Style Tees, Trunk #2Male

    Part Number Features

    SH-BKM/BSM/BKM 5 5 conductor, integral connector drop, 125 V, 8 A, 105C

    SH-BKM/BSM/BKM 5-084-* 5 conductor, cable drop, PVC yellow, 5x18 AWG, 7.0 mm OD, 125 V, 8 A, 105C

    SH-BKM/BSM/BKM 6 6 conductor, integral connector drop, 125 V, 7 A, 105C

    SH-BKM/BSM/BKM 6-085-* 6 conductor, cable drop, PVC yellow, 6x18 AWG, 7.5 mm OD, 125 V, 7 A, 105C

    SH-BKM/BSM/BKM 7 7 conductor, integral connector drop, 125 V, 7 A, 105C

    SH-BKM/BSM/BKM 7-086-* 7 conductor, cable drop, PVC yellow, 7x18 AWG, 8.1 mm OD, 125 V, 7 A, 105C

    SH-BKM/BSM/BKM 8 8 conductor, integral connector drop, 125 V, 7 A, 105C

    SH-BKM/BSM/BKM 8-087-* 8 conductor, cable drop, PVC yellow, 8x18 AWG, 8.5 mm OD, 125 V, 7 A, 105C

    * = Cable length in meters

    SH-BKM/BSM/BKM *

    Wiring Diagrams5 Conductor 6 Conductor 7 Conductor 8 Conductor

    SH-BKM/BSM/BKM -XXX-*

    Dimensions

    = Number of pins

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    Tees

    Part Number Features

    BH-BSM/3BKM 5 5 conductor, integral connector drop, 125 V, 8 A, 105C

    BH-BSM/3BKM 5-084-* 5 conductor, cable drop, PVC yellow, 5x18 AWG, 7.0 mm OD, 125 V, 8 A, 105C

    BH-BSM/3BKM 6 6 conductor, integral connector drop, 125 V, 7 A, 105C

    BH-BSM/3BKM 6-085-* 6 conductor, cable drop, PVC yellow, 6x18 AWG, 7.5 mm OD, 125 V, 7 A, 105C

    BH-BSM/3BKM 7 7 conductor, integral connector drop, 125 V, 7 A, 105C

    BH-BSM/3BKM 7-086-* 7 conductor, cable drop, PVC yellow, 7x18 AWG, 8.1 mm OD, 125 V, 7 A, 105C

    BH-BSM/3BKM 8 8 conductor, integral connector drop, 125 V, 7 A, 105C

    BH-BSM/3BKM 8-087-* 8 conductor, cable drop, PVC yellow, 8x18 AWG, 8.5 mm OD, 125 V, 7 A, 105C

    * = Cable length in meters

    Parallel Wiring Simplifies Wiring Installations ToughMolded Thermoplastic Polyurethane Body IEC IP67 Protection 1Male and 3 Female Connectors

    H-Style Tees, Trunk #1Male

    Female Male

    5-Pin 6-Pin 7-Pin 8-Pin 5-Pin 6-Pin 7-Pin 8-Pin

    Pinouts

    Wiring Diagrams

    BH-BSM/3BKM *

    5 Conductor 6 Conductor 7 Conductor 8 Conductor

    BH-BSM/3BKM -XXX-*

    Dimensions

    = Number of pins

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    Female Male

    5-Pin 6-Pin 7-Pin 8-Pin 5-Pin 6-Pin 7-Pin 8-Pin

    Pinouts

    Parallel Wiring Simplifies Wiring Installations ToughMolded Thermoplastic Polyurethane Body IEC IP67 Protection 3 Female and 1Male Connectors

    Tees, H-Style Tees, Trunk #2Male

    Part Number Features

    BH-BKM/BSM/2BKM 5 5 conductor, integral connector drop, 125 V, 8 A, 105C

    BH-BKM/BSM/2BKM 5-084-* 5 conductor, cable drop, PVC yellow, 5x18 AWG, 7.0 mm OD, 125 V, 8 A, 105C

    BH-BKM/BSM/2BKM 6 6 conductor, integral connector drop, 125 V, 7 A, 105C

    BH-BKM/BSM/2BKM 6-085-* 6 conductor, cable drop, PVC yellow, 6x18 AWG, 7.5 mm OD, 125 V, 7 A, 105C

    BH-BKM/BSM/2BKM 7 7 conductor, integral connector drop, 125 V, 7 A, 105C

    BH-BKM/BSM/2BKM 7-086-* 7 conductor, cable drop, PVC yellow, 7x18 AWG, 8.1 mm OD, 125 V, 7 A, 105C

    BH-BKM/BSM/2BKM 8 8 conductor, integral connector drop, 125 V, 7 A, 105C

    BH-BKM/BSM/2BKM 8-087-* 8 conductor, cable drop, PVC yellow, 8x18 AWG, 8.5 mm OD, 125 V, 7 A, 105C

    * = Cable length in meters

    Wiring Diagrams5 Conductor 6 Conductor 7 Conductor 8 Conductor

    BH-BKM/BSM/2BKM *

    BH-BKM/BSM/2BKM -XXX-*

    Dimensions

    = Number of pins

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    Accesso

    ries

    Connector Style Female Part Number Male Part Number Features Pinout

    BK 5-0 BS 5-0

    Nylon PG 9 cable gland,accepts 6-8 mm cablediameter, solder cup, acceptsup to 5x18 AWG conductors,85C, 60 VAC/DC, 6 A, Mateswith 5-pin cordsets andreceptacles

    BK 6-0 BS 6-0

    Nylon PG 9 cable gland,accepts 6-8 mm cablediameter, solder cup, acceptsup to 6x18 AWG conductors,85C, 60 VAC/DC, 3 A, Mateswith 6-pin cordsets andreceptacles

    BK 7-0 BS 7-0

    Nylon PG 9 cable gland,accepts 6-8 mm cablediameter, solder cup, acceptsup to 7x18 AWG conductors,85C, 60 VAC/DC, 3 A, Mateswith 7-pin cordsets andreceptacles

    BK 8-0 BS 8-0

    Nylon PG 9 cable gland,accepts 6-8 mm cablediameter, solder cup, acceptsup to 8x18 AWG conductors,85C, 60 VAC/DC, 3 A, Mateswith 8-pin cordsets andreceptacles

    For use with CustomWiring orJunction Boxes

    IEC IP67 Protection

    5 - 8 Pin FieldWireable, In-line Connectors

    BS ..

    Male

    Male

    Male

    Male

    BK ..

    Female

    Female

    Female

    Female

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    Connector Style Female Part Number Male Part Number Features Pinouts

    BK 12-0 BS 12-0

    Nylon PG 9 cable gland,accepts 6-8 mm cablediameter solder cup, acceptsup to 12x24 AWG conductors,85C, 60 VDC/VAC, 3 A, mateswith 12-pin cordsets andreceptacles

    BKS 12-0 BSS 12-0

    Stainless steel PG 9 cablegland, accepts 6-8 mm cablediameter solder cup, acceptsup to 12x24 AWG conductors,85C, 60 VDC/VAC, 3 A, mateswith 12-pin cordsets andreceptacles, Shielded

    Standard Nylon and Shielded IEC IP67 Protection

    12-pin FieldWireable, In-line Connectors

    BK ..

    BS ..

    Female

    Male

    BSS ..

    BKS ..

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    Accesso

    ries

    Connector Style Female Part Number Male Part Number Features Pinout

    BK 14-0 BS 14-0

    Nylon PG 9 cable gland,accepts 6-8 mm cablediameter, solder cup,accepts up to 14x24 AWGconductors, 85C, 60VAC/DC, 3 A, Mates withpicofast junction boxes,unshielded

    BK 19-0 BS 19-0

    Nylon PG 9 cable gland,accepts 6-8 mm cablediameter, solder cup,accepts up to 19x24 AWGconductors, 85C, 60VAC/DC, 3 A, Mates withpicofast junction boxes,unshielded

    WBK 14-0 WBS 14-0

    Nylon PG 9 cable gland,accepts 6-8 mm cablediameter, solder cup,accepts up to 14x24 AWGconductors, 85C, 60VAC/DC, 3 A, Mates withpicofast junction boxes,unshielded

    WBK 19-0 WBS 19-0

    Nylon PG 9 cable gland,accepts 6-8 mm cablediameter, solder cup,accepts up to 19x24 AWGconductors, 85C, 60VAC/DC, 3 A, Mates withpicofast junction boxes,unshielded

    Male Connectors For use with CustomWiring or

    Junction Boxes IEC IP67 Protection

    14 and 19-Pin FieldWireable, In-line Connectors

    WBS ..

    BS ..

    Male

    Male

    Male

    Male

    WBK ..

    BK ..

    Female

    Female

    Female

    Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • M16 versafast Connectivity Products

    Connector Style Part Number Features

    BKK-CC Nylon, M16 threads, 4 1/2 inch plastic lanyard and 3/4 inch loop, matesto male cordsets, receptacles, or junction boxes

    BKFK-CCNylon, M16 threads, 2 3/4 inch plastic lanyard and #10 eye-let, matesto male cordsets, receptacles, or junction boxes

    BSK-CC Nylon, M16 threads, 4 1/2 inch plastic lanyard and 3/4 inch loop, matesto female cordsets, receptacles, or junction boxes

    BSFK-CC Nylon, M16 threads, 2 3/4 inch plastic lanyard and #10 eye-let, matesto female cordsets, receptacles, or junction boxes

    BKM-CCNickel plated brass, M16 threads, 6" lanyard, mates with male cordsetsand receptacles

    BKF-CCNickel plated brass, M16 threads, 6" lanyard with eyelet, mates withmale cordsets and receptacles

    BKM-MCNickel plated brass, M16 threads, no lanyard, mates with male cordsetsand receptacles

    BSM-CC Nickel plated brass, M16 threads, 6" lanyard

    BSF-CC Nickel plated brass, M16 threads, 6" lanyard with eyelet

    BSM-MC Nickel plated brass, M16 threads, no lanyard