tw1501127-300 086 rev2 · 2017. 6. 14. · which is approved by cnal. this approval result is...

80

Upload: others

Post on 24-Jan-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

  • Report No: EMC1501127-01 Page 2 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    Special Statement: The testing quality ability of our laboratory meet with "Quality Law of People's Republic

    of China" Clause 19. The testing quality system of our laboratory meets with ISO/IEC-17025 requirements,

    which is approved by CNAL. This approval result is accepted by MRA of APLAC. Our test facility is recognized, certified, or accredited by the following organizations: CNAL-LAB Code: L2292 The EMC Laboratory has been assessed and in compliance with CNAL/AC01:2002

    accreditation criteria for testing Laboratories (identical to ISO/IEC 17025:2005 General Requirements) for the Competence of testing Laboratories.

    FCC-Registration No.: 899988 The EMC Laboratory has been registered and fully described in a report filed with the

    (FCC) Federal Communications commission. The acceptance letter from the FCC is maintained in our files. Registration No.:899988.

    IC- Registration No.: IC5205A-02 The EMC Laboratory has been registered and fully described in a report filed with the (IC)

    Industry Canada. The acceptance letter from the IC is maintained in our files. Registration No.: IC 5205A-02.

  • Report No: EMC1501127-01 Page 3 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    Test Report Conclusion Content 1.0 General Details ……………………..…………………………..……………………………..… 4 1.1 Notes…………………………………………………………..………………….……………… 4 1.2 Test Laboratory………………………………………………………….……………….………. 4 1.3 Details of Applicant……………………………………………………………..………….……. 4 1.4 Application Details………………………..……………………………………..……………….. 4 1.5 Test Item…………………………….…………………………………..…….………………….. 4 1.6 Test Standards…………………………………………………………………………………….. 5 1.7 Test Engineer……………………..………………………………………………………………. 5 2.0 Technical Test…………………………………………………………….……………………… 6 2.1 Summary of Test Result………………………………………………………………………….. 6 2.2 Test Report………………………………………………………….….……….………………… 6 2.3 Frequency Error………………………………………………………………………………….. 7 2.4 Carrier Power (Conducted)………………………………………………………………………. 13 2.5 Effective Radiation Power (Field Strength)……………………………………………………… 20 2.6 Frequency Deviation……………………………………………………………………………… 21 2.7 Adjacent Channel Power………………………………………………………………………… 28 2.8 Spurious Emission……………………………………………………………………………….. 37 2.9 Intermodulation Attenuation……………………………………………………………………… 49 Receiver Parameters 50 2.10 Maximum Usable Sensitivity (Conducted)…………………………….………………………… 50 2.11 Maximum Usable Sensitivity (Field Strength)…………………………………………………… 52 2.12 Co-Channel Selectivity…………………………………………………………………………… 53 2.13 Adjacent Channel Selectivity…………………………………………………………………….. 55 2.14 Spurious Response Rejection…………………………………………………………………….. 57 2.15 Intermodulation Response Rejection…………………………………………………………….. 58 2.16 Block Or Desensitization…………………………………………………………………………. 60 2.17 Spurious Radiation……………………………………………………………………………….. 61 3.0 CE Label……………………………………………………………………………….………… 65 4.0 Photograph-Test Set up……………………………………………………..………………….. 66 5.0 Photograph-EUT………………………………………………………………………………… 67 6.0 Test Equipments………………………………………………………………………………… 79

  • Report No: EMC1501127-01 Page 4 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    1. General Information 1.1 Notes The test results of this report relate exclusively to the test item specified in 1.5. The TIMEWAY Lab does not assume Responsibility for any conclusions and generalizations drawn from the test results with regard to other specimens or samples of the type of the equipment represented by the test item. The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of the TIMEWAY Lab. 1.2 Testing Laboratory Shenzhen Timeway Testing Laboratories Room 512-519, 5/F., East Tower, Building 4, Anhua Industrial Zone, Futian District, Shenzhen, Guangdong,China Tel: +86 755 83448688 Fax :+86 755 83442996 Internet: www.timeway-lab.com Site on File With the Federal Communications and Commission – United States Registration Number: 899988 For 3m & 10 m OATS Site Listed with Industry Canada of Ottawa, Canada Registration Number: IC: 5205A-02 For 3m & 10 m OATS 1.3 Details of Applicant Name: Zhengzhou Eshow Import and Export Trade Co.,Ltd Address: Room 722, Sanjiang Building, No.170,Nanyang Road, Huiji District,Zhengzhou City,Henan,China 1. 4 Application Details Date of Receipt of Application: January 16, 2016 Date of Receipt of Test Item: January 16, 2016 Date of Test: January 16, 2016- August 29, 2016 1.5 Test Item Manufacturer: Shenzhen Retevis Technology Co.,Ltd Address: Room 700,7/F.,13-C,Zhonghaixin Science&Technology Park,No.12 Ganli 6th Road,Buji Street,Longgang District,Shenzhen,China Brand Name: Retevis Model No.: RT6 Additional Brand Name: N/A Additional Model No.: N/A Description: TWO WAY RADIO

  • Report No: EMC1501127-01 Page 6 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    2. Technical Test 2.1 Summary of Test Results

    No deviations from the technical specification(s) were ascertained in the course of the tests Performed

    Final Verdict: (Only “Passed” if all Measurements are “Passed”)

    Passed

    2.2 Test Report

    Test Report Reference List of Measurements

    Parameter to be measured Clause

    Transmitter Parameters

    Frequency Error 4.2.1

    Carrier Power (conducted) 4.2.2

    Effective Radiated Power (Field Strength) 4.2.3

    Adjacent and alternate channel power 4.2.4

    Unwanted emissions in the spurious domain 4.2.5

    Intermodulation Attenuation 4.2.6

    Receiver Parameters

    Maximum Usable Sensitivity (Conducted) 4.3.1

    Co-channel Rejection 4.3.2

    Adjacent Channel Selectivity 4.3.3

    Spurious Response Rejection 4.3.4

    Intermodulation Response Rejection 4.3.5

    Blocking or Desensitization 4.3.6

    Spurious Radiations 4.3.7

    Note: The clause numbers are referenced to ETSI EN 300 086-2 V1.3.1 (2010-06)

  • Report No: EMC1501127-01 Page 7 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    2.3 Frequency Error For Transmitter Test Configuration:

    Test Procedure 1. The method of measurement described under EN 300 086-1, Subclause 7.1.2 2. The test conditions described under EN 300 086-1, Subclause 5.3 and subclause 5.4 Test Results

  • Report No: EMC1501127-01 Page 8 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    The Bottom Channel of 25 kHz Channel Separation for 400-470MHz Band Environment

    Temperature(℃) Power Supplied

    (Vdc) Frequency

    Measured (MHz)Frequency Error

    (kHz) Nominal

    Frequency Limit(kHz)

    T nor (25℃) 7.4V 400.02534 +0.34 400.025 ±2.00

    T min (-20℃) 7.4V 400.02552 +0.52 400.025 ±2.00

    T min (-20℃) 6.3V 400.02537 +0.37 400.025 ±2.00

    T max (+55℃) 7.4V 400.02546 +0.46 400.025 ±2.00

    T max (+55℃) 6.3V 400.02541 +0.41 400.025 ±2.00

    The Middle Channel of 25 kHz Channel Separation for 400-470MHz Band Environment

    Temperature(℃) Power Supplied

    (Vdc) Frequency

    Measured (MHz)Frequency Error

    (kHz) Nominal

    Frequency Limit(kHz)

    T nor (25℃) 7.4V 439.97528 +0.28 439.975 ±2.00

    T min (-20℃) 7.4V 439.97533 +0.33 439.975 ±2.00

    T min (-20℃) 6.3V 439.97546 +0.46 439.975 ±2.00

    T max (+55℃) 7.4V 439.97562 +0.62 439.975 ±2.00

    T max (+55℃) 6.3V 439.97529 +0.29 439.975 ±2.00

    The Top Channel of 25 kHz Channel Separation for 400-470MHz Band

    Environment Temperature(℃)

    Power Supplied (Vdc)

    Frequency Measured (MHz)

    Frequency Error(kHz)

    Nominal Frequency

    Limit(kHz)

    T nor (25℃) 7.4V 469.975 +0.50 469.975 ±2.00

    T min (-20℃) 7.4V 469.975 +0.53 469.975 ±2.00

    T min (-20℃) 6.3V 469.975 +0.46 469.975 ±2.00

    T max (+55℃) 7.4V 469.975 +0.42 469.975 ±2.00

    T max (+55℃) 6.3V 469.975 +0.49 469.975 ±2.00

  • Report No: EMC1501127-01 Page 9 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    The Bottom Channel of 12.5 kHz Channel Separation for 400-470MHz Band Environment

    Temperature(℃) Power Supplied

    (Vdc) Frequency

    Measured (MHz)Frequency Error

    (kHz) Nominal

    Frequency Limit(kHz)

    T nor (25℃) 7.4V 400.02545 +0.45 400.025 ±1.50

    T min (-20℃) 7.4V 400.02541 +0.41 400.025 ±1.50

    T min (-20℃) 6.3V 400.02537 +0.37 400.025 ±1.50

    T max (+55℃) 7.4V 400.02542 +0.42 400.025 ±1.50

    T max (+55℃) 6.3V 400.02535 +0.35 400.025 ±1.50

    The Middle Channel of 12.5 kHz Channel Separation for 400-470MHz Band Environment

    Temperature(℃) Power Supplied

    (Vdc) Frequency

    Measured (MHz)Frequency Error

    (kHz) Nominal

    Frequency Limit(kHz)

    T nor (25℃) 7.4V 439.97532 +0.32 439.975 ±1.50

    T min (-20℃) 7.4V 439.97540 +0.40 439.975 ±1.50

    T min (-20℃) 6.3V 439.97523 +0.23 439.975 ±1.50

    T max (+55℃) 7.4V 439.97542 +0.42 439.975 ±1.50

    T max (+55℃) 6.3V 439.97536 +0.36 439.975 ±1.50

    The Top Channel of 12.5 kHz Channel Separation for 400-470MHz Band

    Environment Temperature(℃)

    Power Supplied (Vdc)

    Frequency Measured (MHz)

    Frequency Error(kHz)

    Nominal Frequency

    Limit(kHz)

    T nor (25℃) 7.4V 469.97546 +0.46 469.975 ±1.50

    T min (-20℃) 7.4V 469.97541 +0.41 469.975 ±1.50

    T min (-20℃) 6.3V 469.97538 +0.38 469.975 ±1.50

    T max (+55℃) 7.4V 469.97537 +0.37 469.975 ±1.50

    T max (+55℃) 6.3V 469.97526 +0.26 469.975 ±1.50

  • Report No: EMC1501127-01 Page 10 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    The Top Channel of 12.5 kHz Channel Separation for 136-174MHz Band Environment

    Temperature(℃) Power Supplied

    (Vdc) Frequency

    Measured (MHz)Frequency Error

    (kHz) Nominal

    Frequency Limit(kHz)

    T nor (25℃) 7.4V 173.97534 +0.34 173.975 ±1.50

    T min (-20℃) 7.4V 173.97526 +0.26 173.975 ±1.50

    T min (-20℃) 6.3V 173.97522 +0.22 173.975 ±1.50

    T max (+55℃) 7.4V 173.97537 +0.37 173.975 ±1.50

    T max (+55℃) 6.3V 173.97542 +0.42 173.975 ±1.50

    The Middle Channel of 12.5 kHz Channel Separation for 136-174MHz Band

    Environment Temperature(℃)

    Power Supplied (Vdc)

    Frequency Measured (MHz)

    Frequency Error(kHz)

    Nominal Frequency

    Limit(kHz)

    T nor (25℃) 7.4V 156.02538 +0.38 156.025 ±1.50

    T min (-20℃) 7.4V 156.02564 +0.64 156.025 ±1.50

    T min (-20℃) 6.3V 156.02536 +0.36 156.025 ±1.50

    T max (+55℃) 7.4V 156.02562 +0.62 156.025 ±1.50

    T max (+55℃) 6.3V 156.02557 +0.57 156.025 ±1.50

    The Bottom Channel of 12.5 kHz Channel Separation for 136-174MHz Band Environment

    Temperature(℃) Power Supplied

    (Vdc) Frequency

    Measured (MHz)Frequency Error

    (kHz) Nominal

    Frequency Limit(kHz)

    T nor (25℃) 7.4V 136.02551 +0.51 136.025 ±1.00

    T min (-20℃) 7.4V 136.02546 +0.46 136.025 ±1.00

    T min (-20℃) 6.3V 136.02559 +0.59 136.025 ±1.00

    T max (+55℃) 7.4V 136.02544 +0.44 136.025 ±1.00

    T max (+55℃) 6.3V 136.02563 +0.63 136.025 ±1.00

  • Report No: EMC1501127-01 Page 11 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    The Top Channel of 25 kHz Channel Separation for 136-174MHz Band Environment

    Temperature(℃) Power Supplied

    (Vdc) Frequency

    Measured (MHz)Frequency Error

    (kHz) Nominal

    Frequency Limit(kHz)

    T nor (25℃) 7.4V 173.97543 +0.43 173.975 ±2.00

    T min (-20℃) 7.4V 173.97552 +0.52 173.975 ±2.00

    T min (-20℃) 6.3V 173.97557 +0.57 173.975 ±2.00

    T max (+55℃) 7.4V 173.97545 +0.45 173.975 ±2.00

    T max (+55℃) 6.3V 173.97550 +0.50 173.975 ±2.00

    The Middle Channel of 25 kHz Channel Separation for 136-174MHz Band Environment

    Temperature(℃) Power Supplied

    (Vdc) Frequency

    Measured (MHz)Frequency Error

    (kHz) Nominal

    Frequency Limit(kHz)

    T nor (25℃) 7.4V 156.02548 +0.48 156.025 ±2.00

    T min (-20℃) 7.4V 156.02537 +0.37 156.025 ±2.00

    T min (-20℃) 6.3V 156.02553 +0.53 156.025 ±2.00

    T max (+55℃) 7.4V 156.02566 +0.66 156.025 ±2.00

    T max (+55℃) 6.3V 156.02549 +0.49 156.025 ±2.00

    The Bottom Channel of 25 kHz Channel Separation for 136-174MHz Band

    Environment Temperature(℃)

    Power Supplied (Vdc)

    Frequency Measured (MHz)

    Frequency Error(kHz)

    Nominal Frequency

    Limit(kHz)

    T nor (25℃) 7.4V 136.02542 +0.42 136.025 ±1.35

    T min (-20℃) 7.4V 136.02560 +0.60 136.025 ±1.35

    T min (-20℃) 6.3V 136.02558 +0.58 136.025 ±1.35

    T max (+55℃) 7.4V 136.02549 +0.49 136.025 ±1.35

    T max (+55℃) 6.3V 136.02551 +0.51 136.025 ±1.35

  • Report No: EMC1501127-01 Page 12 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    Limits: EN 300 086-1, subclause 7.1.3 The frequency error shall not exceed the Values given in table 2.

  • Report No: EMC1501127-01 Page 13 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    2.4 Carrier Power For Transmitter Test Configuration

    Test Procedure 1. The method of measurement described under EN 300 086-1, Subclause 7.2.2 2. The test conditions described under EN 300 086-1, Subclause 5.3 and 5.4 Test Result

    The Top Channel of 12.5 kHz Channel Separation for 400-470MHz Band

    Test Conditions Power Measured

    (dBm)

    Power Error

    (dB) Temperature (℃) Voltage (V)

    T Nor (25℃) 7.4 36.69 -0.33

    T min (-20℃) 7.4 36.77 -0.22

    6.3 36.60 -0.39

    T Max (+55℃) 7.4 36.72 -0.27

    6.3 36.63 -0.36

    Nominal Power=36.99dBm

    Result Pass

  • Report No: EMC1501127-01 Page 14 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    The Middle Channel of 12.5 kHz Channel Separation for 400-470MHz Band

    Test Conditions Power Measured

    (dBm)

    Power Error

    (dB) Temperature (℃) Voltage (V)

    T Nor (25℃) 7.4 36.69 -0.30

    T min (-20℃) 7.4 36.72 -0.27

    6.3 36.56 -0.43

    T Max (+55℃) 7.4 36.76 -0.23

    6.3 36.63 -0.36

    Nominal Power=36.99dBm

    Result Pass

    The Bottom Channel of 12.5 kHz Channel Separation for 400-470MHz Band

    Test Conditions Power Measured

    (dBm)

    Power Error

    (dB) Temperature (℃) Voltage (V)

    T Nor (25℃) 7.4 36.75 -0.24

    T min (-20℃) 7.4 36.76 -0.23

    6.3 36.58 -0.41

    T Max (+55℃) 7.4 36.60 -0.39

    6.3 36.55 -0.44

    Nominal Power=36.99dBm

    Result Pass

  • Report No: EMC1501127-01 Page 15 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    The Top Channel of 25 kHz Channel Separation for 400-470MHz Band

    Test Conditions Power Measured

    (dBm)

    Power Error

    (dB) Temperature (℃) Voltage (V)

    T Nor (25℃) 7.4 36.72 -0.27

    T min (-20℃) 7.4 36.76 -0.23

    6.3 36.62 -0.37

    T Max (+55℃) 7.4 36.75 -0.24

    6.3 36.58 -0.41

    Nominal Power=36.99dBm

    Result Pass

    The Middle Channel of 25 kHz Channel Separation for 400-470MHz Band

    Test Conditions Power Measured

    (dBm)

    Power Error

    (dB) Temperature (℃) Voltage (V)

    T Nor (25℃) 7.4 36.76 -0.23

    T min (-20℃) 7.4 36.68 -0.31

    6.3 36.62 -0.37

    T Max (+55℃) 7.4 36.78 -0.21

    6.3 36.61 -0.38

    Nominal Power=36.99dBm

    Result Pass

  • Report No: EMC1501127-01 Page 16 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    The Bottom Channel of 25 kHz Channel Separation for 400-470MHz Band

    Test Conditions Power Measured

    (dBm)

    Power Error

    (dB) Temperature (℃) Voltage (V)

    T Nor (25℃) 7.4 36.69 -0.30

    T min (-20℃) 7.4 36.73 -0.26

    6.3 36.51 -0.48

    T Max (+55℃) 7.4 36.68 -0.31

    6.3 36.56 -0.43

    Nominal Power=36.99dBm

    Result Pass

    The Bottom Channel of 12.5 kHz Channel Separation for 136-174MHz Band

    Test Conditions Power Measured

    (dBm)

    Power Error

    (dB) Temperature (℃) Voltage (V)

    T Nor (25℃) 7.4 36.68 -0.31

    T min (-20℃) 7.4 36.73 -0.26

    6.3 36.45 -0.54

    T Max (+55℃) 7.4 36.72 -0.27

    6.3 36.51 -0.48

    Nominal Power=36.99dBm

    Result Pass

  • Report No: EMC1501127-01 Page 17 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    The Middle Channel of 12.5 kHz Channel Separation for 136-174MHz Band

    Test Conditions Power Measured

    (dBm)

    Power Error

    (dB) Temperature (℃) Voltage (V)

    T Nor (25℃) 7.4 36.66 -0.33

    T min (-20℃) 7.4 36.64 -0.35

    6.3 36.57 -0.42

    T Max (+55℃) 7.4 36.63 -0.36

    6.3 36.49 -0.50

    Nominal Power=36.99dBm

    Result Pass

    The Top Channel of 12.5 kHz Channel Separation 136-174MHz Band

    Test Conditions Power Measured

    (dBm)

    Power Error

    (dB) Temperature (℃) Voltage (V)

    T Nor (25℃) 7.4 36.70 -0.29

    T min (-20℃) 7.4 36.65 -0.34

    6.3 36.42 -0.57

    T Max (+55℃) 7.4 36.58 -0.41

    6.3 36.46 -0.53

    Nominal Power=36.99dBm

    Result Pass

  • Report No: EMC1501127-01 Page 18 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    The Top Channel of 25 kHz Channel Separation 136-174MHz Band

    Test Conditions Power Measured

    (dBm)

    Power Error

    (dB) Temperature (℃) Voltage (V)

    T Nor (25℃) 7.4 36.65 -0.34

    T min (-20℃) 7.4 36.69 -0.30

    6.3 36.36 -0.63

    T Max (+55℃) 7.4 36.55 -0.44

    6.3 36.47 -0.52

    Nominal Power=36.99dBm

    Result Pass

    The Middle Channel of 25 kHz Channel Separation 136-174MHz Band

    Test Conditions Power Measured

    (dBm)

    Power Error

    (dB) Temperature (℃) Voltage (V)

    T Nor (25℃) 7.4 36.56 -0.43

    T min (-20℃) 7.4 36.68 -0.31

    6.3 36.45 -0.54

    T Max (+55℃) 7.4 36.67 -0.32

    6.3 36.52 -0.47

    Nominal Power=36.99dBm

    Result Pass

  • Report No: EMC1501127-01 Page 19 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    The Bottom Channel of 25 kHz Channel Separation 136-174MHz Band

    Test Conditions Power Measured

    (dBm)

    Power Error

    (dB) Temperature (℃) Voltage (V)

    T Nor (25℃) 7.4 36.55 -0.44

    T min (-20℃) 7.4 36.63 -0.36

    6.3 36.51 -0.48

    T Max (+55℃) 7.4 36.46 -0.53

    6.3 36.40 -0.59

    Nominal Power=36.99dBm

    Result Pass

    Limits: EN 300 086-1, subclause 5.1.2 The transmitter power (conducted) under the specified conditions of measurement (see clause 7.2.2) and at normal test conditions (see clause 5.3), shall be within ±1,5 dB of the rated carrier power (conducted). The transmitter power (conducted) under extreme test conditions (see clause 5.4) shall be within +2,0 dB and -3,0 dB of the rated output power.

  • Report No: EMC1501127-01 Page 20 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    2.5 Maximum Effective Radiated Power (Field Strength) (Not Applicable to Device with External RF Port) Test Configuration N/A Test Procedure N/A Test Results N/A

  • Report No: EMC1501127-01 Page 21 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    2.6 Frequency Deviation Test Configuration

    Test Procedure 1. The method of measurement described under EN 300 086-1, Subclause 7.4.2.1 and 7.4.2.2 2. The test conditions described under EN 300 086-1, Subclause 5.3 Test Result

  • Report No: EMC1501127-01 Page 22 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    The Middle Channel of 12.5 kHz Channel Separation for 400-470MHz

    Modulation Frequency (kHz)

    Deviation (kHz) Modulation Frequency (kHz)

    Deviation (kHz)

    0.3 1.66 2.4 1.49 0.4 1.72 2.55 1.46 0.5 1.80 2.6 1.37 0.6 1.89 2.8 1.28 0.7 1.85 3.0 1.20 0.8 1.96 3.5 1.02 0.9 2.02 4.0 0.81 1.0 2.05 4.5 0.62 1.2 1.92 5.0 0.42 1.4 1.85 6.0 0.27 1.6 1.79 8.0 0.20 1.8 1.66 10.0 0.14 2.0 1.60 12.0 0.02 2.2 1.51 12.5 0.01

  • Report No: EMC1501127-01 Page 23 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    The Middle Channel of 25 kHz Channel Separation for 400-470MHz Band

    Modulation Frequency (kHz)

    Deviation (kHz) Modulation Frequency (kHz)

    Deviation (kHz)

    0.3 2.43 2.6 3.43 0.4 2.56 2.8 3.29 0.5 2.78 3.0 3.11 0.6 3.06 3.5 2.67 0.7 3.18 4.0 2.23 0.8 3.58 4.5 1.76 0.9 3.62 5.0 1.6 1.0 3.79 6.0 1.38 1.2 4.02 8.0 0.86 1.4 4.11 10.0 0.33 1.6 4.05 12.0 0.03 1.8 3.96 14.0 0.02 2.0 3.86 16.0 0.01 2.2 3.7 20.0 0.01 2.4 3.63 25.0 0.001

  • Report No: EMC1501127-01 Page 24 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    The Middle Channel of 12.5 kHz Channel Separation for 136-174MHz

    Modulation Frequency (kHz)

    Deviation (kHz) Modulation Frequency (kHz)

    Deviation (kHz)

    0.3 1.71 2.4 1.58 0.4 1.68 2.55 1.41 0.5 1.84 2.6 1.26 0.6 1.9 2.8 1.07 0.7 1.83 3.0 0.86 0.8 1.95 3.5 0.72 0.9 2.02 4.0 0.64 1.0 1.97 4.5 0.52 1.2 1.98 5.0 0.36 1.4 1.87 6.0 0.23 1.6 1.83 8.0 0.17 1.8 1.72 10.0 0.12 2.0 1.64 12.0 0.01 2.2 1.56 12.5 0.01

  • Report No: EMC1501127-01 Page 25 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    The Middle Channel of 25 kHz Channel Separation for 136-174MHz Band

    Modulation Frequency (kHz)

    Deviation (kHz) Modulation Frequency (kHz)

    Deviation (kHz)

    0.3 2.61 2.6 3.23 0.4 2.77 2.8 3.17 0.5 2.85 3.0 3.06 0.6 3.11 3.5 2.71 0.7 3.29 4.0 2.56 0.8 3.43 4.5 1.82 0.9 3.59 5.0 1.56 1.0 3.68 6.0 1.34 1.2 3.89 8.0 0.81 1.4 4.02 10.0 0.37 1.6 3.95 12.0 0.02 1.8 3.77 14.0 0.01 2.0 3.58 16.0 0.01 2.2 3.41 20.0 0.01 2.4 3.36 25.0 0.001

  • Report No: EMC1501127-01 Page 26 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    Limit ETSI EN 300 086-1 Subclause 7.4.3.1 The maximum permissible frequency deviation for modulation frequencies from the lowest frequency transmitted (f1) by the equipment (as declared by the manufacturer) up to (f2) shall be as given in table 3.

    ETSI EN 300 086-1 Subclause 7.4.3.2 The frequency deviation at modulation frequencies between 3,0 kHz (for equipment operating with 20 kHz or 25 kHz channel separations) and 2,55 kHz (for equipment operating with 12,5 kHz channel separation) and 6,0 kHz shall not exceed the frequency deviation at a modulation frequency of 3,0 kHz/2,55 kHz. At 6,0 kHz the deviation shall be not more than 30,0 % of the maximum permissible frequency deviation. The frequency deviation at modulation frequencies between 6,0 kHz and a frequency equal to the channel separation for which the equipment is intended shall not exceed that given by a linear representation of the frequency deviation (dB) relative to the modulation frequency, starting at the 6,0 kHz limit and having a slope of -14,0 dB per octave. These limits are illustrated in figure 6.

  • Report No: EMC1501127-01 Page 27 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

  • Report No: EMC1501127-01 Page 28 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    2.7 Adjacent and alternate channel power Test Configuration

    Test Procedure 1. The method of measurement described under EN 300 086-1, Subclause 7.5.2 2. The test conditions described under EN 300 086-1, Subclause 5.3

  • Report No: EMC1501127-01 Page 29 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    Test Results

    The Top Channel of 12.5 kHz Channel Separation for 400-470MHz Band

    Test Condition Measurement Offset Adjacent Channel Power (dBm)

    Temperature (℃) Voltage(V)

    T Nor (25℃) V Nor (7.4V) +8.25kHz -57.3

    -8.25kHz -57.2

    Applicable Limit 60dB down or 0.2uW

    Result Pass

    The Middle Channel of 12.5 kHz Channel Separation for 400-470MHz Band

    Test Condition Measurement Offset Adjacent Channel Power (dBm)

    Temperature (℃) Voltage(V)

    T Nor (25℃) V Nor (7.4V) +8.25kHz -58.1

    -8.25kHz -58.3

    Applicable Limit 60dB down or 0.2uW

    Result Pass

    The Bottom Channel of 12.5 kHz Channel Separation for 400-470MHz Band

    Test Condition Measurement Offset Adjacent Channel Power (dBm)

    Temperature (℃) Voltage(V)

    T Nor (25℃) V Nor (7.4V) +8.25kHz -57.7

    -8.25kHz -57.6

    Applicable Limit 60dB down or 0.2uW

    Result Pass

  • Report No: EMC1501127-01 Page 30 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    The Top Channel of 25 kHz Channel Separation for 400-470MHz Band

    Test Condition Measurement Offset Adjacent Channel Power (dBm)

    Temperature (℃) Voltage(V)

    T Nor (25℃) V Nor (7.4V) +17kHz -58.9

    -17kHz -58.8

    Applicable Limit 60dB down or 0.2uW

    Result Pass

    The Bottom Channel of 25 kHz Channel Separation for 400-470MHz Band

    Test Condition Measurement Offset Adjacent Channel Power (dBm)

    Temperature (℃) Voltage(V)

    T Nor (25℃) V Nor (7.4V) +17kHz -59.6

    -17kHz -59.7

    Applicable Limit 60dB down or 0.2uW

    Result Pass

    The Bottom Channel of 25 kHz Channel Separation for 400-470MHz Band

    Test Condition Measurement Offset Adjacent Channel Power (dBm)

    Temperature (℃) Voltage(V)

    T Nor (25℃) V Nor (7.4V) +17kHz -58.9

    -17kHz -58.6

    Applicable Limit 60dB down or 0.2uW

    Result Pass

  • Report No: EMC1501127-01 Page 31 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    The Top Channel of 12.5 kHz Channel Separation for400-470MHz Band

    Test Condition Measurement Offset Alternate Channel Power (dBm)

    Temperature (℃) Voltage(V)

    T Nor (25℃) V Nor (7.4V) +20.25kHz -68.4

    -20.25kHz -68.3

    Applicable Limit 70dB down or 0.2uW

    Result Pass

    The Middle Channel of 12.5 kHz Channel Separation for400-470MHz Band

    Test Condition Measurement Offset Alternate Channel Power (dBm)

    Temperature (℃) Voltage(V)

    T Nor (25℃) V Nor (7.4V) +20.25kHz -69.1

    -20.25kHz -68.0

    Applicable Limit 70dB down or 0.2uW

    Result Pass

    The Bottom Channel of 12.5 kHz Channel Separation for 400-470MHz Band

    Test Condition Measurement Offset Alternate Channel Power (dBm)

    Temperature (℃) Voltage(V)

    T Nor (25℃) V Nor (7.4V) +20.25kHz -68.5

    -20.25kHz -68.7

    Applicable Limit 70dB down or 0.2uW

    Result Pass

  • Report No: EMC1501127-01 Page 32 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    The Top Channel of 25 kHz Channel Separation for400-470MHz Band

    Test Condition Measurement Offset Alternate Channel Power (dBm)

    Temperature (℃) Voltage(V)

    T Nor (25℃) V Nor (7.4V) +42kHz -66.1

    -42kHz -66.0

    Applicable Limit 70dB down or 0.2uW

    Result Pass

    The Bottom Channel of 25 kHz Channel Separation for400-470MHz Band

    Test Condition Measurement Offset Alternate Channel Power (dBm)

    Temperature (℃) Voltage(V)

    T Nor (25℃) V Nor (7.4V) +42kHz -66.3

    -42kHz -66.3

    Applicable Limit 70dB down or 0.2uW

    Result Pass

    The Bottom Channel of 25 kHz Channel Separation for 400-470MHz Band

    Test Condition Measurement Offset Alternate Channel Power (dBm)

    Temperature (℃) Voltage(V)

    T Nor (25℃) V Nor (7.4V) +42kHz -66.5

    -42kHz -66.8

    Applicable Limit 70dB down or 0.2uW

    Result Pass

  • Report No: EMC1501127-01 Page 33 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    The Top Channel of 12.5 kHz Channel Separation for 136-174MHz Band

    Test Condition Measurement Offset Adjacent Channel Power (dBm)

    Temperature (℃) Voltage(V)

    T Nor (25℃) V Nor (7.4V) +8.25kHz -58.3

    -8.25kHz -58.2

    Applicable Limit 60dB down or 0.2uW

    Result Pass

    The Middle Channel of 12.5 kHz Channel Separation for 136-174MHz Band

    Test Condition Measurement Offset Adjacent Channel Power (dBm)

    Temperature (℃) Voltage(V)

    T Nor (25℃) V Nor (7.4V) +8.25kHz -58.7

    -8.25kHz -58.6

    Applicable Limit 60dB down or 0.2uW

    Result Pass

    The Bottom Channel of 12.5 kHz Channel Separation for 136-174MHz Band

    Test Condition Measurement Offset Adjacent Channel Power (dBm)

    Temperature (℃) Voltage(V)

    T Nor (25℃) V Nor (7.4V) +8.25kHz -59.2

    -8.25kHz -59.4

    Applicable Limit 60dB down or 0.2uW

    Result Pass

  • Report No: EMC1501127-01 Page 34 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    The Top Channel of 25 kHz Channel Separation for 136-174MHz Band

    Test Condition Measurement Offset Adjacent Channel Power (dBm)

    Temperature (℃) Voltage(V)

    T Nor (25℃) V Nor (7.4V) +17kHz -59.7

    -17kHz -59.6

    Applicable Limit 60dB down or 0.2uW

    Result Pass

    The Bottom Channel of 25 kHz Channel Separation for 136-174MHz Band

    Test Condition Measurement Offset Adjacent Channel Power (dBm)

    Temperature (℃) Voltage(V)

    T Nor (25℃) V Nor (7.4V) +17kHz -59.8

    -17kHz -60.0

    Applicable Limit 60dB down or 0.2uW

    Result Pass

    The Bottom Channel of 25 kHz Channel Separation for 136-174MHz Band

    Test Condition Measurement Offset Adjacent Channel Power (dBm)

    Temperature (℃) Voltage(V)

    T Nor (25℃) V Nor (7.4V) +17kHz -60.4

    -17kHz -60.3

    Applicable Limit 60dB down or 0.2uW

    Result Pass

  • Report No: EMC1501127-01 Page 35 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    The Top Channel of 12.5 kHz Channel Separation for 136-174MHz Band

    Test Condition Measurement Offset Alternate Channel Power (dBm)

    Temperature (℃) Voltage(V)

    T Nor (25℃) V Nor (7.4V) +20.25kHz -69.3

    -20.25kHz -69.4

    Applicable Limit 70dB down or 0.2uW

    Result Pass

    The Middle Channel of 12.5 kHz Channel Separation for 136-174MHz Band

    Test Condition Measurement Offset Alternate Channel Power (dBm)

    Temperature (℃) Voltage(V)

    T Nor (25℃) V Nor (7.4V) +20.25kHz -69.2

    -20.25kHz -69.1

    Applicable Limit 70dB down or 0.2uW

    Result Pass

    The Bottom Channel of 12.5 kHz Channel Separation for 136-174MHz Band

    Test Condition Measurement Offset Alternate Channel Power (dBm)

    Temperature (℃) Voltage(V)

    T Nor (25℃) V Nor (7.4V) +20.25kHz -69.6

    -20.25kHz -69.7

    Applicable Limit 70dB down or 0.2uW

    Result Pass

  • Report No: EMC1501127-01 Page 36 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    The Top Channel of 25 kHz Channel Separation for 136-174MHz Band

    Test Condition Measurement Offset Alternate Channel Power (dBm)

    Temperature (℃) Voltage(V)

    T Nor (25℃) V Nor (7.4V) +42kHz -67.5

    -42kHz -67.6

    Applicable Limit 70dB down or 0.2uW

    Result Pass

    The Bottom Channel of 25 kHz Channel Separation for 136-174MHz Band

    Test Condition Measurement Offset Alternate Channel Power (dBm)

    Temperature (℃) Voltage(V)

    T Nor (25℃) V Nor (7.4V) +42kHz -67.8

    -42kHz -67.9

    Applicable Limit 70dB down or 0.2uW

    Result Pass

    The Bottom Channel of 25 kHz Channel Separation for 136-174MHz Band

    Test Condition Measurement Offset Alternate Channel Power (dBm)

    Temperature (℃) Voltage(V)

    T Nor (25℃) V Nor (7.4V) +42kHz -67.3

    -42kHz -67.5

    Applicable Limit 70dB down or 0.2uW

    Result Pass

    Limit For a channel separation of 12,5 kHz, 20 kHz and 25 kHz, the adjacent channel power shall not exceed a value of 60,0 dB below the transmitter power (conducted) without the need to be below 0,2 μW (-37 dBm). For a channel separation of 12,5 kHz, 20 kHz and 25 kHz, the alternate channel power shall not exceed a value of 70,0 dB below the transmitter power (conducted) without the need to be below 0,2 μW (-37 dBm).

  • Report No: EMC1501127-01 Page 37 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    2.8 Unwanted emissions in the spurious domain Test Configuration Conducted Measurement (9 kHz to 4GHz)

    Effective Radiated Power measurement (30MHz to 4GHz) Below 1G

  • Report No: EMC1501127-01 Page 38 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    Above 1GHz

    Test Procedure

  • Report No: EMC1501127-01 Page 39 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    1. Please refer to ETSI EN 300 086-1 (V1.4.1) Sub-clause 5.3 for the test conditions. 2. Please refer to ETSI EN 300 086-1 (V1.4.1) Sub-clause 7.6.2 and 7.6.3 for the measurement method Test Results Both the conducted measurement and radiated measurement are performed to the three channels Conducted Measurement (9 kHz to 4GHz)

  • Report No: EMC1501127-01 Page 40 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    The Bottom Channel of 12.5 KHz Channel separation for 400-470 MHz Band

    Test Condition Frequency (MHz)

    Conducted Power (dBm) Temperature (℃) Voltage (V)

    T Nor ( 25 ℃) V Nor (7.4V)

    800.05 -46.5

    1200.08 -53.3 1600.12 -60.4

    Result Pass

  • Report No: EMC1501127-01 Page 41 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    The Bottom Channel of 25 kHz Channel Separation for 400-470 MHz Band

    Test Condition Frequency (MHz)

    Conducted Power (dBm) Temperature (℃) Voltage (V)

    T Nor ( 25 ℃) V Nor (7.4V) 800.05 -46.7 1200.08 -54.6 1600.12 -60.6

    Result Pass

  • Report No: EMC1501127-01 Page 42 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    The Top Channel of 12.5 kHz Channel separation for 400-470 MHz Band

    Test Condition Frequency (MHz)

    Conducted Power (dBm) Temperature (℃) Voltage (V)

    T Nor ( 25 ℃) V Nor (7.4V)

    939.95 -48.1

    1409.93 -53.9 1879.9 -61.2

    Result

  • Report No: EMC1501127-01 Page 43 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    The Top Channel of 25 kHz Channel Separation for 400-470 MHz Band

    Test Condition Frequency (MHz)

    Conducted Power (dBm) Temperature (℃) Voltage (V)

    T Nor ( 25 ℃) V Nor (7.4V) 939.95 -49.7 1409.93 -57.1 1879.9 -61.6

    Result Pass

  • Report No: EMC1501127-01 Page 44 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    The Bottom Channel of 12.5 kHz Channel separation for 136-174 MHz Band

    Test Condition Frequency (MHz)

    Conducted Power (dBm) Temperature (℃) Voltage (V)

    T Nor ( 25 ℃) V Nor (7.4V)

    272.05 -45.4

    408.08 -52.2 544.12 -58.3

    Result Pass

  • Report No: EMC1501127-01 Page 45 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    The Bottom Channel of 25 kHz Channel Separation for 136-174 MHz Band

    Test Condition Frequency (MHz)

    Conducted Power (dBm) Temperature (℃) Voltage (V)

    T Nor ( 25 ℃) V Nor (7.4V) 272.05 -45.9 408.08 -50.6 544.12 -59.5

    Result Pass

  • Report No: EMC1501127-01 Page 46 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    The Top Channel of 12.5 kHz Channel Separation for 136-174 MHz Band

    Test Condition Frequency (MHz)

    Conducted Power (dBm) Temperature (℃) Voltage (V)

    T Nor ( 25 ℃) V Nor (7.4V) 347.95 -46.8

    521.93 -53.2 Result Pass

  • Report No: EMC1501127-01 Page 47 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    The Top Channel of 25 kHz Channel Separation for 136-174 MHz Band

    Test Condition Frequency (MHz)

    Conducted Power (dBm) Temperature (℃) Voltage (V)

    T Nor ( 25 ℃) V Nor (7.4V) 347.95 -46.3

    521.93 -52.6 Result Pass

    Note: Worse cases were recorded

  • Report No: EMC1501127-01 Page 48 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    Effective Radiated Power measurement (30MHz to 4GHz or 12.75GHz) For 12.5 kHz/ 25 kHz channel separation

    Frequency (MHz) Emission Level (dBm) Limit Margin (dB) NF -- -- --

    NF=No peak value was found Notes: For the receiving mode is the standby mode, all the test data and applicable limit, both conducted and radiated, is acquired from the operating mode. Limit The power of any spurious radiation shall not exceed the values given in tables 5a and 5b.

  • Report No: EMC1501127-01 Page 49 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    2.9 Intermodulation attenuation (Not applicable to this portable device) Test Configuration N/A Test Procedure N/A Test Results N/A Limit Two classes of transmitter intermodulation attenuation are defined, the equipment shall fulfil one of the requirements as follows: - the intermodulation attenuation ratio shall be at least 40,0 dB for any intermodulation component; - for base stations to be used in special service conditions (e.g. at sites where more than one transmitter will be in service) or when the regulatory authority makes it a condition of the licence, the intermodulation attenuation ratio shall be at least 70,0 dB for any intermodulation component. In the case where the performance is achieved by additional internal or external isolating devices (such as circulators) these are expected to be available at the time the measurements are made and shall be used for the measurements.

  • Report No: EMC1501127-01 Page 50 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    Receiver Parameters 2.10 Maximum Usable Sensitivity (Conducted) Test Configuration

    Test Procedure 1. Please refer to ETSI EN 300 086-1 (V1.4.1) Sub-clause 5.3 and 5.4 for the test conditions 2. Please refer to ETSI EN 300 086-1 (V1.4.1) Sub-clause 8.1.2 for the measurement method Test Result

    12.5 kHz Channel Separation for 400-470MHz Band Test condition Result Measured

    (dBuV) Limit

    (dBuV) Temperature (℃) Voltage (V) T Nor (25℃) 3.7 4.6 6.0

    T Min (-20℃) 3.7 5.2 12 3.1 5.4 12

    T Max (+55℃) 3.7 4.5 12 3.1 4.8 12

    Result Pass

  • Report No: EMC1501127-01 Page 51 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    25 kHz Channel Separation for 400-470MHz Band Test condition Result Measured

    (dBuV) Limit

    (dBuV) Temperature (℃) Voltage (V) T Nor (25℃) 3.7 4.2 6.0

    T Min (-20℃) 3.7 4.6 12 3.1 5.1 12

    T Max (+55℃) 3.7 5.5 12 3.1 4.9 12

    Result Pass

    12.5 kHz Channel Separation for 136-174MHz Band

    Test condition Result Measured (dBuV)

    Limit (dBuV) Temperature (℃) Voltage (V)

    T Nor (25℃) 3.7 4.6 6.0

    T Min (-20℃) 3.7 4.9 12 3.1 5.4 12

    T Max (+55℃) 3.7 5.5 12 3.1 5.3 12

    Result Pass

    25 kHz Channel Separation for 136-174MHz Band

    Test condition Result Measured

    (dBuV) Limit

    (dBuV) Temperature (℃) Voltage (V) T Nor (25℃) 3.7 4.8 6.0

    T Min (-20℃) 3.7 5.2 12 3.1 5.6 12

    T Max (+55℃) 3.7 5.9 12 3.1 6.1 12

    Result Pass Limit The maximum usable sensitivity shall not exceed an electromotive force (emf) of +6,0 dBμV under normal test conditions, and an emf of +12,0 dBμV under extreme test conditions.

  • Report No: EMC1501127-01 Page 52 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    2.11 Maximum Usable Sensitivity (Field Strength) ( Not Applicable to Device With External RF Port) Test Configuration N/A Test Procedure N/A Test Results N/A Limit

  • Report No: EMC1501127-01 Page 53 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    2.12 Co-Channel Rejection Test Configuration

    Test Procedure 1. Please refer to ETSI EN 300 086-1 (V1.4.1) Sub-clause 6.3 for the test conditions 2. Please refer to ETSI EN 300 086-1 (V1.4.1) Sub-clause 8.4.2 for the measurement method Test Result

    Test Result of 12.5 kHz Channel Separation for 400-470MHz Band Test Result (dB) Limit (dB)

    -5.7 Between -12dB to 0dB Result Pass

    Test Result of 25 kHz Channel Separation for 400-470MHz Band

    Test Result (dB) Limit (dB) -4.9 Between -8dB to 0dB

    Result Pass

  • Report No: EMC1501127-01 Page 54 of 80Date: 2016-08-30

    The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.

    Test Result of 12.5 kHz Channel Separation for 136-174MHz Band

    Test Result (dB) Limit (dB) -4.6 Between -12dB to 0dB

    Result Pass

    Test Result of 25 kHz Channel Separation for 136-174MHz Band Test Result (dB) Limit (dB)

    -4.2 Between -8dB to 0dB Result Pass

    Limit The value of the co-channel rejection ratio, expressed in dB, at any frequency of the unwanted signal within the specified range, shall be between: - -8.0 dB an