tws enterprise erase array training

9
Enterprise Array Erasure Training TECHWAY SERVICES, INC.

Upload: techwayservices

Post on 02-Jun-2015

81 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TWS Enterprise Erase Array Training

Enterprise ArrayErasure Training

TECHWAY SERVICES, INC.

Page 2: TWS Enterprise Erase Array Training

Enterprise Array Erasure

• EMC • Network Appliance• Total Storage System• Compellent Storage• Power Vault

Page 3: TWS Enterprise Erase Array Training

Tools

• 2U Unit Server Chassis fitted with appropriate controller cards

• Monitor, Keyboard and Mouse• Technician Cart• Cable Management Straps

• Failed Drive Labels

Page 4: TWS Enterprise Erase Array Training

Process1. Verify with POC that all units to be wiped have been disconnected from the network.2. Perform a physical count of total drives in unit using architecture map3. Power on Techway 2U unit4. Connect cabling to unit to be wiped5. Power on unit to be wiped6. Allow drives to load (approx. 1 sec per drive) by using terminal view7. Connect cabling to Techway 2U Unit from system to be wiped8. Open Tabernus EE Array Application9. Verify all drives have been detected10. Select all drives and add unit asset serial number11. Select all drives and begin erasure12. After completion of wiping process view log csv file and verify the physical count to the recorded count of drives wiped.13. Pull ALL failed drives from unit and attached failed drive sticker, log drive on Pulled Failed Drive Reporting Form and give

to site POC14. Only after 100% match of the physical count to the record count has been verified, then continue to the next batch and

repeat steps 3 -13 until complete15. After unit completion contact TWS Project Manager with update16. Fill out TWS Daily Project Summary Form17. Email the following to TWS Project Manager daily :• Signed TWS Daily Project Summary Form• All log files from server• Architecture Map• Pulled Failed Drive Reporting Form• Onsite Acknowledgment Form (After Project Completion)

Page 5: TWS Enterprise Erase Array Training

Disk FailureIn case of drive failure, a sticker will be attached to the failed drive with the following information:

Expected failure rate of 1-3% on enterprise level drives

1. Identify failed drive2. Affix completed label to top of hard drive 3. Give to site POC

Page 6: TWS Enterprise Erase Array Training

Processing Time

There are three determining factors in project processing expectation:

1. Type of drive ( Fiber Channel, SAS, PATA,SATA)2. Type of Device Cabling ( 1-3 GB)3. Time allotted in facility

Drive Type Drive Size in GB MB per Second Erase Hours (3x erase)

SAS 300 85 3.00

FC 300 75 3.40

SCSI 300 70 3.70

SATA 300 50 5.10

IDE / PATA 300 40 6.40