typical sanitary schematic - winnipeg · 2016. 11. 16. · wc wc lav lav lav ex. ex. wcwc ex. lav...

1
BASEMENT MAIN FLOOR MEZZANINE ROOF 100Ø SAN NEW 50Ø VENT STACK EXISTING SANITARY CONFIRM SIZE ON SITE PRIOR TO CONNECTION OF NEW SANITARY DRAINS 32Ø VENT KS CRAWLSPACE 38Ø SAN 50Ø VENT LUNCH ROOM STAFF WASHROOM DF BASEMENT MAIN FLOOR MEZZANINE ROOF 50Ø VENT 50Ø VENT EXISTING SANITARY CONFIRM SIZE ON SITE PRIOR TO CONNECTION OF NEW SANITARY DRAINS CRAWLSPACE NEW WASHROOM WC WC LAV LAV LAV EX. WC EX. WC EX. LAV EX. LAV NEW MS CONNECT NEW 50Ø VENT TO EXISTING EXISTING 50Ø VENT STACK IN FALSE COLUMN TO BE RELOCATED TO EXTERIOR WALL NEW WASHROOM NEW WASHROOM 100Ø SAN 32Ø VENT 50Ø VENT 50Ø VENT WC 32Ø VENT 32Ø VENT NEW FD LAV WC 50Ø VENT 32Ø VENT 38Ø VENT WC LAV NEW WASHROOM 100Ø SAN CO CO CO 38Ø SAN 50Ø SAN 50Ø VENT WC LAV 38Ø SAN 100Ø SAN 32Ø VENT 32Ø VENT BASEMENT MAIN FLOOR MEZZANINE ROOF W EXISTING 25Ø DOMESTIC WATER SERVICE EXISTING 19Ø WATER METER 13Ø DCW & DHW TO KS CRAWLSPACE 19Ø DCW TO LAV & WC 13Ø DCW TO LAV 13Ø DCW & DHW TO LAVATORIES 19Ø DCW TO LAV & WC 13Ø DCW TO LAV 13Ø DCW TO DF TO EXISTING WASHROOMS STAFF WASHROOM LUNCH ROOM NEW WASHROOM 19Ø DCW TO LAV & WC 13Ø DCW TO LAV NEW WASHROOM EXISTING DOMESTIC WATER SUPPLY CONFIRM SIZE AND LOCATION ON SITE PRIOR TO NEW CONNECTION EXISTING GAS FIRE DOMESTIC HOT WATER TANK 13Ø DCW TO MS 13Ø DHW TO MS NEW MOP SINK 19Ø DCW TO NEW WATER CLOSETS This drawing is property of the Architect and cannot be reproduced or used without the consent of the Architect. The contractor is responsible for checking and verifying all levels and dimensions and shall report all discrepancies to the Architect and obtain clarification prior to commencing work. Sheet No: 1 ISSUED FOR CONSTRUCTION SEPT 09, 2016 Project: Project Number: Drawing Title: # Issue/Revision Date 16054 6 Fermor Ave., Winnipeg, Manitoba St. Vital Library THE CITY OF WINNIPEG PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT MUNICIPAL ACCOMMODATIONS DIVISION 4TH FLOOR - 185 KING STREET R3B 1J1 Bid Opportunity Number: 768-2016 MECHANICAL SCHEDULES AND SANITARY & DOMESTIC WATER SCHEMATICS Certificate of Authorization HDK Consulting Incorporated Date: No. 5539 04/30/2017 NTS TYPICAL SANITARY SCHEMATIC 1 NTS TYPICAL SANITARY SCHEMATIC 2 NTS TYPICAL DOMESTIC WATER SCHEMATIC 3 M-9

Upload: others

Post on 25-Jan-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

  • BASEMENT

    MAIN FLOOR

    MEZZANINE

    ROOF

    100Ø SAN

    NEW 50Ø

    VENT STACK

    EXISTING SANITARY CONFIRM SIZE

    ON SITE PRIOR TO CONNECTION

    OF NEW SANITARY DRAINS

    32Ø VENT

    KS

    CRAWLSPACE

    38Ø SAN

    50Ø VENT

    LUNCH ROOM

    STAFF

    WASHROOM

    DF

    BASEMENT

    MAIN FLOOR

    MEZZANINE

    ROOF

    50Ø VENT

    50Ø VENT

    EXISTING SANITARY CONFIRM SIZE

    ON SITE PRIOR TO CONNECTION

    OF NEW SANITARY DRAINS

    CRAWLSPACE

    NEW

    WASHROOM

    WCWC

    LAV LAV

    LAV

    EX.

    WC

    EX. WC

    EX.

    LAV

    EX.

    LAV

    NEW MS

    CONNECT NEW 50Ø VENT

    TO EXISTING

    EXISTING 50Ø VENT STACK IN

    FALSE COLUMN TO BE RELOCATED

    TO EXTERIOR WALL

    NEW

    WASHROOM

    NEW

    WASHROOM

    100Ø SAN

    32Ø VENT

    50Ø VENT

    50Ø VENT

    WC

    32Ø VENT

    32Ø VENT

    NEW FD

    LAV

    WC

    50Ø VENT

    32Ø VENT

    38Ø VENT

    WC

    LAV

    NEW

    WASHROOM

    100Ø SAN

    COCO

    CO

    38Ø SAN

    50Ø SAN

    50Ø VENT

    WC

    LAV

    38Ø SAN

    100Ø SAN

    32Ø VENT32Ø VENT

    BASEMENT

    MAIN FLOOR

    MEZZANINE

    ROOF

    W

    EXISTING 25Ø DOMESTIC

    WATER SERVICE

    EXISTING 19Ø

    WATER METER

    13Ø DCW &

    DHW TO KS

    CRAWLSPACE

    19Ø DCW TO LAV & WC

    13Ø DCW TO LAV

    13Ø DCW & DHW

    TO LAVATORIES

    19Ø DCW TO LAV & WC

    13Ø DCW TO LAV

    13Ø DCW TO DF

    TO EXISTING

    WASHROOMS

    STAFF

    WASHROOM

    LUNCH ROOM

    NEW

    WASHROOM

    19Ø DCW TO LAV & WC

    13Ø DCW TO LAV

    NEW

    WASHROOM

    EXISTING DOMESTIC WATER SUPPLY

    CONFIRM SIZE AND LOCATION ON

    SITE PRIOR TO NEW CONNECTION

    EXISTING GAS FIRE

    DOMESTIC HOT WATER

    TANK

    13Ø DCW TO MS

    13Ø DHW TO MS

    NEW MOP

    SINK

    19Ø DCW TO

    NEW WATER

    CLOSETS

    This drawing is property of the Architect and cannot

    be reproduced or used without the consent of the

    Architect. The contractor is responsible for checking

    and verifying all levels and dimensions and shall

    report all discrepancies to the Architect and obtain

    clarification prior to commencing work.

    Sheet No:

    1 ISSUED FOR

    CONSTRUCTION

    SEPT 09, 2016

    Project:

    Project Number:

    Drawing Title:

    # Issue/Revision Date

    16054

    6 Fermor Ave., Winnipeg, Manitoba

    St. Vital Library

    THE CITY OF WINNIPEG PLANNING,

    PROPERTY AND DEVELOPMENT

    DEPARTMENT

    MUNICIPAL ACCOMMODATIONS DIVISION

    4TH FLOOR - 185 KING STREET

    R3B 1J1

    Bid Opportunity Number: 768-2016

    MECHANICAL SCHEDULES

    AND SANITARY & DOMESTIC

    WATER SCHEMATICS

    Certificate of Authorization

    HDK Consulting Incorporated

    Date:No. 5539

    04/30/2017

    NTS

    TYPICAL SANITARY SCHEMATIC

    1

    NTS

    TYPICAL SANITARY SCHEMATIC

    2

    NTS

    TYPICAL DOMESTIC WATER SCHEMATIC

    3

    M-9