u – led modules, converters and systems signage · data sheet 03/15-led210-3 u – led modules,...

7
www.tridonic.com 1 Subject to change without notice. Data sheet 03/15-LED210-3 U – LED modules, converters and systems SIGNAGE Product description • LED chain for backlighting of light boxes, letters, symbols and complex contours in signage applications • Optimised for use in signage • High colour consistency (MacAdam 4) • Beam characteristic: 120° • LED module with strain relief • Integrated current source to stabilise luminous flux • Flexible chain, can be split between any module • Mounting with screw or premounted double-sided adhesive tape possible • Nominal life-time up to 50,000 h (at ta 60 °C) È Standards, page 4 Colour temperatures and tolerances, page 6, 7 Upanel P581 G1 EXCITE upanel

Upload: others

Post on 24-Sep-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: U – LED modules, converters and systems SIGNAGE · Data sheet 03/15-LED210-3 U – LED modules, converters and systems SIGNAGE Product description • LED chain for backlighting

www.tridonic.com 1Subject to change without notice.

Data sheet 03/15-LED210-3

U – LED modules, converters and systemsSIGNAGE

Product description

•LEDchainforbacklightingoflightboxes,letters,symbolsand

complexcontoursinsignageapplications

•Optimisedforuseinsignage

•Highcolourconsistency(MacAdam4)

•Beamcharacteristic:120°

•LEDmodulewithstrainrelief

• Integratedcurrentsourcetostabiliseluminousflux

•Flexiblechain,canbesplitbetweenanymodule

•Mountingwithscreworpremounteddouble-sidedadhesivetape

possible

•Nominallife-timeupto50,000h(atta60°C)

ÈStandards,page4

Colour temperatures and tolerances,page6,7

Upanel P581 G1 EXCITEupanel

Page 2: U – LED modules, converters and systems SIGNAGE · Data sheet 03/15-LED210-3 U – LED modules, converters and systems SIGNAGE Product description • LED chain for backlighting

www.tridonic.com 2Subject to change without notice.

Data sheet 03/15-LED210-3

U – LED modules, converters and systemsSIGNAGE

Technical dataAmbienttemperatureta -40...+60°C

Max.surfacetemperatureonmoduletc1 70°C

Storagetemperaturets -40...+60°C

Typeofprotection IP00

Riskgroup(EN62471:2008) 0

Upanel P581 G1 EXCITEupanel

40 534,6

190 ø3,2

3x10

60 ±tbd 10 5,35

8080

20

5010tc

220 220

Ordering data

Type Article number Colour Wavelengthrange

Colourtemperature5

14 light points per module

LED P581-C DL 24 60 25 00 D G1 28000614 Daylightwhite – 6,500K

LED P581-C LW 24 60 25 00 D G1 28000615 Lightwhite – 5,000KPackaging:1piece/roll,10pieces/carton,160pieces/pallet

Specific technical dataType Photometric

code2 5Wavelengthrange

Colour

temperature4Typ.luminousflux

permodule2Colourrendering

indexCRI2SupplyvoltageDC3 Typ.current

permodule2Typ.powerpermodule

Luminousefficacy

Energyclassificationpermodule

14 light points per moduleLED P581-C DL 765/4xx – 6,500K 100lm >70 24V 39mA 0.94W 106lm/W A++

LED P581-C LW 750/4xx – 5,000K 100lm >70 24V 39mA 0.94W 106lm/W A++

1 Ifthemax.temperaturelimitsareexceeded,thelifeofthemodulewillbegreatlyreducedorthemodulemaybedamaged.Fortheprecisepositionofthetcpointseetheabovediagram.

2 Tolerancerangeforopticalandelectricaldata:±15%.

3 Exceedingthemax.operatingvoltageleadstoanoverloadontheuchain.Thismayinturnresultinareductioninlife-timeorevenindestruction.Tolerancerangeforthesupplyvoltage:24V:+2V/-0V.

4 Colourtemperatureforinformationonly.Validcoloursee‚CoordinatesandtolerancesaccordingtoCIE1931‘.

5 Photometriccodeinevaluation.

Allvaluesatta=25°C.

Page 3: U – LED modules, converters and systems SIGNAGE · Data sheet 03/15-LED210-3 U – LED modules, converters and systems SIGNAGE Product description • LED chain for backlighting

www.tridonic.com 3Subject to change without notice.

Data sheet 03/15-LED210-3

U – LED modules, converters and systemsSIGNAGE

LEDP581-C upanelP581

LW Colour=Lightwhite

24 Supplyvoltage=24V

60 ModuledistanceD=60mm

25 Numberofmodules=25

00 Typeofprotection=IP00

D Beamcharcteristic=120°

G1 Generation=1

Type code

Example:LEDP581-CLW24602500DG1

FormoreinformationpleasecalloremailyourTridoniccontact.

1st digit 2nd + 3rd digit 4th digit 5th digit 6th digit

Code CRIColourtemperaturein

Kelvinx100McAdamsinitial

McAdamsafter25%ofthelife-time

(max.6000h)

Lumenmaintananceafter25%ofthelife-time(max.6000h)

Code Remaininglumen7 67–76 7 ≥70%8 77–86 8 ≥80%9 87–≥90 9 ≥90%

Photometric code

Keyforphotometriccode,e.g.861/449

LED control gear matrix – Upanel CRYSTAL CLASSIC

IN-BUILT LCU1 REMOTE LCU2

TypeLCU

060/24 D010LCU 100/24

D010LCU

150/24 D010LCU

035/24 E020LCU 060/24

E020LCU 100/24

E020LCU

150/24 E020

Article number

22185184 22185185 22185186 24166320 24166324 24166328 24166333

Assignable LED control gear Assignable LED control gear

TypeNumber of modules Number of modules Max.

chainingMin. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max.

LED P581-C DL 7 55 14 92 28 138 5 32 7 55 14 92 28 138 100

LED P581-C LW 7 55 14 92 28 138 5 32 7 55 14 92 28 138 100

1 TypeofprotectionIP67.

2 TypeofprotectionIP20.

Page 4: U – LED modules, converters and systems SIGNAGE · Data sheet 03/15-LED210-3 U – LED modules, converters and systems SIGNAGE Product description • LED chain for backlighting

www.tridonic.com 4Subject to change without notice.

Data sheet 03/15-LED210-3

U – LED modules, converters and systemsSIGNAGE

Thermal behaviour

operationtemperature(operation,nodefects) ta -40→+60°C

storagetemperature ts -40→+60°C

max.temperaturetcpoint tc 70°C

Thevaluesapplytooperationat100%output,naturalconvection.Ifthemaximumtemperaturelimitsareexceeded,thelifeofthemodulewillbegreatlyreduced.Themodulecanfailwithinashorttime.Thetcpointtemperatureofthemodulehastobemeasuredinthethermallystablestateandunderoperatingconditions.Measurementsetupe.g.accordingtoIEC/EN60598-1.

Standards

•EN62031•EN62471

Theproductmeetsthe“inbuiltLEDmodule“classificationaccordingtoEN62031.

Certificates

•ENEC•ULfile:E313318•CSAfile:249699

Mounting instruction

NoneofthecomponentsoftheupanelCRYSTAL(substrate,LED,electroniccomponentsetc.)maybeexposedtotensileorcompressivestresses.

Max.torqueforfixing:0.5Nm.

TheLEDmodulesaremountedwithmin.2screwspermodule.Inordernottodamagethemodulesonlyroundedheadscrewsandanadditionalplasticflatwashershouldbeused.

ChemicalsubstancemayharmtheLEDmodule.Chemicalreactionscouldleadtocolourshift,reducedluminousfluxoratotalfailureofthemodulecausedbycorrosionofelectricalconnections.

MaterialswhichareusedinLEDapplications(e.g.sealings,adhesives)mustnotproducedissolvergas.Theymustnotbecondensationcuringbased,acetatecuringbasedorcontainsulfur,chlorineorphthalate.Avoidcorrosiveatmosphereduringusageandstorage.

EOS/ESD safety guidelines

Thedevice/modulecontainscomponentsthataresensitivetoelectro-staticdischargeandmayonlybeinstalledinthefactoryandonsiteifappropriateEOS/ESDprotectionmeasureshavebeentaken.Nospecialmeasuresneedbetakenfordevices/moduleswithenclosedcasings(contactwiththepcboardnotpossible),justnormalinstallationprac-tice.PleasenotetherequirementssetoutinthedocumentEOS/ESDguidelines(Guideline_EOS_ESD.pdf)at:http://www.tridonic.com/com/en/technical-data.asp

Selection of the LED control gearupanelCRYSTALshallbeoperatedwithSELVLEDcontrolgears.

upanelCRYSTALarebasicisolatedagainstgroundandcanbemounteddirectlyonearthedmetalpartsoftheluminaire.Inthiscasethelightemittingsideofthemodulehastobeprotectedagainstdirecttouch(testfinger).Thisistypicallyachievedbymeansofanonremovablelightdistributoroverthemodule.

Electrical supply/choice of LED control gearIfaLEDcontrolgearotherthanTridonicuconverterisused,itmustprovidethefollowingprotection:•Short-circuitprotection•Overloadprotection•Overtemperatureprotection

upanelCRYSTALmustbesuppliedbyaconstantvoltageLEDcontrolgear.OperationwithaconstantcurrentLEDcontrolgearcanleadtoanirrever-sibledamageofthemodule.

Lumen maintenance

Lumen depreciation ta temperature 60 °C

L70B10 50,000hL70B50 50,000hL80B10 50,000hL80B50 50,000hL90B10 34,000hL90B50 50,000h

Remarks:• Lumendepreciation–thedecreaseinlumenoutputthatoccursasalampisoperated.

• L70orL70–shorthandforlumendepreciationto70%ofinitiallumenoutputindicates70%lumenmaintenance.L50wouldbelumendepreciationof50%.

• B50–anotheraspectofLEDlifeprojection,usedinconjunctionwiththelumendepreciation.B50indicatesnomorethan50%ofasampleofLEDdeviceswouldbeexpectedtofailbeforeacertainnumberofoperatinghours.Failuremeanslightoutputdropsbelowatargetlumenmaintenancelevel(suchasL70orL50).B10wouldmeannomorethan10%ofthesamplefailswithinthegiventime.

Page 5: U – LED modules, converters and systems SIGNAGE · Data sheet 03/15-LED210-3 U – LED modules, converters and systems SIGNAGE Product description • LED chain for backlighting

www.tridonic.com 5Subject to change without notice.

Data sheet 03/15-LED210-3

U – LED modules, converters and systemsSIGNAGE

Wiring example

Empirical values for decrease of luminous flux over the chain

Type Colour Module distance60 mm

Number of modules

LEDP581-CDL Daylightwhite 0% 25LEDP581-CLW Lightwhite 0% 25

WiringCable:AWG18

Colour red-white whiteFunction + –

–+

Uconverter

LN

Label product packaging (sample)

Label carton (sample)

South KoreaLED P581-C DL 24

1 pc

28000614

25.01.2014

60 25 00 D G1

1

2

36

5

SCZZZZZZZZ LT4

7

Batch

South Korea

6

7

LED P581-C DL 24

10 pcs

28000614

25.01.2014

60 25 00 D G1

1

2

3

5

SCZZZZZZZZ LT4Batch

Label product (sample)

1 Type2 Electr.specification3 Generation4 Articlecode5 Productiondate6 Productionbatch7 Normativesymbols

1

2

3

5

4

67

P581-C LW G128000615Vf = 24 VP = 0W94Tc = 85 °CSCBBBBBBBB MMYY

Made in South Korea

1 Type2 Packagingquantity3 Articlecode4 Productionbatch5 Productiondate6 BarcodeEAN13forpackagingunit7 BarcodeEAN128(includesEAN13andbatchnumber)

1 Type2 Packagingquantity3 Articlecode4 Productionbatch5 Productiondate6 BarcodeEAN13forpackagingunit7 BarcodeEAN128(includesEAN13andbatchnumber)

Page 6: U – LED modules, converters and systems SIGNAGE · Data sheet 03/15-LED210-3 U – LED modules, converters and systems SIGNAGE Product description • LED chain for backlighting

www.tridonic.com 6Subject to change without notice.

Data sheet 03/15-LED210-3

U – LED modules, converters and systemsSIGNAGE

Beam characteristics 120°

Light distribution Iv/Ivmax.

Coordinates and tolerances according to CIE 1931

Daylight white (DL)

x0 y0Centre 0.3135 0.3284

MacAdamellipse:4SDCM

0,3100

0,3150

0,3200

0,3250

0,3300

0,3350

0,3400

0,3450

0,3500

0,29

50

0,30

00

0,30

50

0,31

00

0,31

50

0,32

00

0,32

50

0,33

00

0,33

50

Light white (LW)

x0 y0Centre 0.3451 0.3552

MacAdamellipse:4SDCM

0,3350

0,3400

0,3450

0,3500

0,3550

0,3600

0,3650

0,3700

0,3750

0,32

50

0,33

00

0,33

50

0,34

00

0,34

50

0,35

00

0,35

50

0,36

00

0,36

50

20

20

-20 40

40

60

60

80

100

80 100-40-60-80-100

10°-10°20°-20°

-30°

-40°

-50°

-60°

30°

40°

50°

60°

70°

80°

90°00

relativeintensityIv/Iv,max

Page 7: U – LED modules, converters and systems SIGNAGE · Data sheet 03/15-LED210-3 U – LED modules, converters and systems SIGNAGE Product description • LED chain for backlighting

www.tridonic.com 7Subject to change without notice.

Data sheet 03/15-LED210-3

U – LED modules, converters and systemsSIGNAGE

0,2000

0,2200

0,2400

0,2600

0,2800

0,3000

0,3200

0,3400

0,3600

0,3800

0,4000

0,4200

0,4400

0,4600

0,4800

0,5000

0,20

00

0,22

00

0,24

00

0,26

00

0,28

00

0,30

00

0,32

00

0,34

00

0,36

00

0,38

00

0,40

00

0,42

00

0,44

00

0,46

00

0,48

00

0,50

00

Daylight white

Light white