U-Series
Bastidor Abierto_Tomo II Complementos Técnicos.
LV & MV Circuit Breakers
/Air Circuit BreakerU-Series
24
Dimensions
(unit: mm)
270
296
337.4
404.
4
270
422.4
168.7 253.7
404.
4
381
[ 3P ] [ 4P ]
152.
55
186.
810
9 20
ø14 ø14
85 8515
152.
55
186.
810
9 20
85 85 8515
3333
0
60 49 186.8
132
144
5050
295.8 43.6
2550
15
352-ø13 3-ø13
3333
0
60 49 186.8
7513
214
4
43.6
50 75
15
35
295.8
[ 630-1,600A ] [ 2,000A ]
Front
Vertical terminal connection
| UAN06-20/UAS06-16 fixed type (A frame) |
※ A frame 2,000A of UAN fixed type is applicable horizontal terminal only.
ACB
Air Circuit Breaker_25
85 8550
85 85 8550
152.
55
186.
810
9 20
ø14
152.
55
186.
810
9 20
ø14
3333
0
60 49 186.8
132
144
1515
129 25
50
15
352-ø13
295.8 43. 6
85 8550
85 85 8550
152.
55
186.
810
9 20
ø14
152.
55
186.
810
9 20
ø14
3333
0
60 49 186.8
25 50
15
352-ø13
295.8
252.415
118
526
(unit: mm)
Front terminal connection
Horizontal terminal connection
/Air Circuit BreakerU-Series
26
Dimensions
(unit: mm)
| UAN06-20/UAS06-16 draw-out type (A frame) |
328
164164
413
460
(Aut
o co
nnec
tion
type
)
249164
278.
3
501525
438
(Man
ual c
ontr
ol p
lug
type
)
460
(Aut
o co
nnec
tion
type
)
438
(Man
ual c
ontr
ol p
lug
type
) ø12.1
ø12.1
416440
270 270
[ 3P ] [ 4P ]
28.8
250
210
28.8
250
59 210 85
85 85 8515
85 8515
ø14 ø14
368.
4
368.
4
421.2
381.6
132
144
5050
2550
15
35
328.8
250
(Test)
(Isol)
26.5
11.5
26.511.5
352.8
50
20.4
60
119.3 6
15
15ø13 ø13
465.
8
33.1
330
39.6
50 75
15
35 3-ø132-ø13
328.8250
(Test)
(Isol)
352.8
50
381.6
132
144
7575
20.460
421.2
119.3 6
15
15
465.
8
Arc shield surface(Option)
Arc shield surface(Option)
Fixing block(Option)
Fixing block(Option)
33.1
330
39.6
[ 630-1,600A ] [ 2,000A ]
※ A frame 2,000A of UAN fixed type is applicable horizontal terminal only.
Vertical terminal connection
Front
ACB
Air Circuit Breaker_27
(unit: mm)
Arc shield surface(Option)
Fixing block(Option)
28.8
250
210
28.8
250
59 210 85
85 85 8550
85 8550
ø14
ø13
ø14
368.
4
368.
4421.2381.6
132
144
1515
129 25
50
15
352-ø13
328.8250
(Test)
(Isol)
352.8
50
20.4
60
119.3 6
15
15
465.
8
33.1
330
39.6
26.5
11.5
28.8
250
210
28.8
250
59 210 85
85 85 8550
85 8550
25 50
15
35 2-ø13
328.8
250
(Test)
(Isol)
26.5
11.5
352.8
50
20.460
119.3 6
15
15ø13
465.
8
Arc shield surface
Fixing block
(Option)
(Option)
33.1
330
ø14ø14
368.
4
368.
4
39.6
329.6 15
118
526
Front terminal connection
Horizontal terminal connection
/Air Circuit BreakerU-Series
28
270
367
408.4
270
482
523.4
204.2 319.2
404.
4
404.
4
[ 3P ] [ 4P ]
115 115 115 115 115
20 20
152.
55
186.
810
9 20
ø14 ø14152.
55
186.
810
9 20
3333
0
60 49 186.8
7575
132
144
50 75
15
353-ø13
295.8 43. 6
3333
0
60 49 186.8
132
144
43. 6
90
50 90
15
353-ø13
295.8
90
[ 630-2,500A ] [ 3,200A ]
Dimensions
(unit: mm)
| UAN06-32/UAS20-32 fixed type (B frame) |
Vertical terminal connection
Front
ACB
Air Circuit Breaker_29
152.
55
186.
810
9 20
ø14 ø14152.
55
186.
810
9 20
A A115 115 115 115 115
3333
0
60 49 186.8
20
132
144
50 75
15
353-ø13
295.8 43.6
3333
0
60 49 186.8
20
132
144
50 90
15
353-ø13
295.8 43. 6
[ 3,200A ][ 630~2,500A ]
152.
55
186.
810
9 20
ø14
152.
55
186.
810
9 20
ø14
3333
0
60 49 186.8
75115 115
75115 115 115
50 75
15
353-ø13
295.8
257.420
118
644
(unit: mm)
Front terminal connection
Name Detail “A”
UAN06-25 75
UAN32 90
Horizontal terminal connection
/Air Circuit BreakerU-Series
30
399199.5199.5
514314.5199.5
460
(Aut
o co
nnec
tion
type
)
438
(Man
ual c
ontr
ol p
lug
type
)
270
278.
3
278.
3
270
460
(Aut
o co
nnec
tion
type
)
438
(Man
ual c
ontr
ol p
lug
type
)
487
511
602
626
ø12.1
ø12.1
[ 3P ] [ 4P ]
ø14 ø14
28.8
250
210
115 115
28.8
250
94.5 210 115
115 115 11520 20
368.
4
368.
4
423.2383.6
7575
143
132.
5
328.8250
(Test)
(Isol)
26.5
11.5
352.8
50
20.4
60
119.3 6
15
15ø13 ø13
465.
8
Arc shield surface(Option)
Arc shield surface(Option)
33.1
330
39.6
50 75
15
353-ø13
423.2383.6
143
9090
50 90
15
353-ø13
132.
5
328.8250
(Test)
(Isol)
26.5
11.5
352.8
50
20.4
60
119.3 6
15
15
465.
8
Fixing block(Option)
Fixing block(Option)
33.1
330
39.6
[ 630-2,500A ] [ 3,200A ]
Dimensions
(unit: mm)
| UAN06-32/UAS20-32 draw-out type (B frame) |
Vertical terminal connection
Front
ACB
Air Circuit Breaker_31
ø14 ø14
28.8
250
210
A115 115
28.8
250
94.5 210 115
A115 115 115
368.
4
368.
4
50 75
15
35
423.2383.6
2012
420
143
132.
5
328.8250
(Test)
(Isol)
26.5
11.5
352.8
50
20.4
60
119.3 6
15
15ø13
465.
8
Arc shield surface(Option)
Arc shield surface(Option)
Arc shield surface(Option)
33.1
330
39.6423.2383.6
2012
420
143
50 90
15
353-ø13
3-ø13
132.
5328.8
250
(Test)
(Isol)
26.5
11.5
352.8
50
20.4
60
119.3 6
15
15ø13
465.
8
Fixing block(Option)
Fixing block(Option)
Fixing block(Option)
33.1
330
39.6
[ 630-2,500A ] [ 3,200A ]
28.8
250
210
75115 115
28.8
250
94.5 210 115
75115 115 115
50 75
15
35 3-ø13
ø14 ø14
368.
4
368.
4
328.8
250
(Test)
(Isol)
26.5
11.5
352.8
50
20.460
119.3 6
15
15ø13
465.
8
33.1
330
39.6
329.6
117.
552
5.5
20
(unit: mm)
Front terminal connection
Name Detail “A”
UAN06-25 75
UAN32 90
Horizontal terminal connection
/Air Circuit BreakerU-Series
32
270
367
408.4
270
482
523.4
204.2 319.2
404.
4
404.
4
152.
55
186.
810
9 20
ø14 ø14152.
55
186.
810
9 20
1515 10
152.5 152.5
1515 10
140 140 140
3333
0
60 49 186.8
5712
512
544
119.
516
9
25*4
=100
125
15
35 5-ø13
295.8 87
[ 3P ] [ 4P ]
Dimensions
(unit: mm)
| UAN40 fixed type (B frame) |
Vertical terminal connection
Front
ACB
Air Circuit Breaker_33
152.
55
186.
810
9 20
ø14 152.
55
186.
810
9 20
ø14
100
140 140 140
520
100
152.5 152.5
405
3333
0
60 49 186.8
4015
1510
144
132
58.6295.8
100
15
35 3-ø13
25*3
=75
(unit: mm)
Horizontal terminal connection
/Air Circuit BreakerU-Series
34
399
199.5199.5
514
314.5199.5
460
(Aut
o co
nnec
tion
type
)
438
(Man
ual c
ontr
ol p
lug
type
)
270
278.
3
ø12.1
278.
3
ø12.1
270
460
(Aut
o co
nnec
tion
type
)
438
(Man
ual c
ontr
ol p
lug
type
)
487
511
602
626
28.8
250
210
28.8
250
94.5 210 115
1515 10
152.5 152.5
1515 10
140 140 140
ø14ø14
368.
4
368.
4
465.2425.6
107.
519
3
125
6812
5
25*4
=100
125
15
35 5-ø13
465.
8
Arc shield surface(Option)
328.8250
(Test)
(Isol)
26.5
11.5
352.8
50
20.4
60
119.3 6
15
15ø13
33.1
330
39.6
Fixing block(Option)
[ 3P ] [ 4P ]
Dimensions
(unit: mm)
| UAN40 draw-out type (B frame) |
Vertical terminal connection
Front
ACB
Air Circuit Breaker_35
28.8
250
210
28.8
250
94.5 210 115
100152. 5 152. 5
100
140 140 140
405 520
ø1 4ø14
368.
4
368.
4
439.2399.6
4015
1510
100
15
35 3-ø13
132.
516
8
25*3
=75
328.8250
(Test)
(Isol)
26.5
11.5
352.8
50
20.4
60
119.3 6
15
15ø13
465.
8
Arc shield surface(Option)
Fixing block(Option)
33.1
330
39.6
(unit: mm)
Horizontal terminal connection
/Air Circuit BreakerU-Series
36
404.
4
270
168.7464.7
633.4
592 762
404.
4
270
253.7549.7
803.4
152.
55
186.
810
9 20
14870 2020
190.5 190.5
152.
5
5
186.
810
9 20
190.5 190.5190.5
70 2020 148
3333
0
60 49 186.8
194
107
44.5
125
6912
5
25*4
=100
125
15
35 5-ø13
295.8 63.6
[ 3P ] [ 4P ]
Dimensions
(unit: mm)
| UAN32-50 fixed type (C frame) |
Vertical terminal connection
Front
ACB
Air Circuit Breaker_37
148
190.5 190.5
152.
55
186.
810
9 20
148
190.5 190.5 190.5
125
152.
55
186.
810
9 20
3333
0
60 49 186.8
2070
20
196
106
110
8611
051
25*4
=100
125
15
35 5-ø13
295.8 63.6
(unit: mm)
Horizontal terminal connection
/Air Circuit BreakerU-Series
38
624
164460270
460
(Aut
o co
nnec
tion
type
)
438
(Man
ual c
ontr
ol p
lug
type
)
460
(Aut
o co
nnec
tion
type
)
438
(Man
ual c
ontr
ol p
lug
type
)
278.
3
ø12.1
712
736
794
249545
270
278.
3
ø12.1
882
906
103.
850
175
70 2020
545 249
345 345
148
24 126
ø14 368.
4
103.
850
175
14870 2020
190.5 190.5 190.5 190.5 190.5
460 164
260 260
ø14 368.
4
25*4
=100
125
15
35 5-ø13
441.2
401.6
194
107
44.5
125
6912
5
328.8175
(Test)
(Isol)
26.5
11.5
352.8
50
20.460
119.3 6
15
15ø13
465.
8
Arc shield surface
Fixing block
(Option)
(Option)
33.1
330
39.6
Dimensions
(unit: mm)
| UAN32-50 draw-out type (C frame) |
Vertical terminal connection
Front
ACB
Air Circuit Breaker_39
103.
850
175
148190.5 190.5
460 164260 260
ø14 36
8.4
103.
850
175
545 249345 345
148190.5 190.5 190.5
125
ø14 368.
4
25*4
=100
125
15
35 5-ø13
441.2401.6
110
110
2070
20
328.8175
(Test)(Isol)
26.511.5
352.8
50
20.460
119.3 6
15
15ø13
465.
8
Arc shield surface
Fixing block
(Option)
(Option)
33.1
330
106
196
5186
39.6
(unit: mm)
Horizontal terminal connection
/Air Circuit BreakerU-Series
40
Dimensions
Front Side Rear (IP30)
(Test)26.5(Isol)11.5
292100
12-Ø
4
103.5 4-R5
122.
5
345
7.5
7.5
122.
511
5
103.5
25.6
20.460
33.1
330
A
CB
3132
Panel door
Rear panel (IP30)
(25) (323)
Operaing panel center
4
ACB center
3333
0
7513
214
4
Rear panel (IP30)
(95) (188)
A
CB
ACB center
Panel door
292
100
12-Ø
4
103.5 4-R5
122.
5
345
7.5
7.5
122.
511
5
103.5
25.6
Operaing panel center
Real panel cutting size
Model A B C
UAN06-20 / UAS06-16 / A frame, 3P 283 355 25
UAN06-20 / UAS06-16 / A frame, 4P 368 355 25
UAN06-40 / UAS20-32 / B frame, 3P 354 355 25
UAN06-40 / UAS20-32 / B frame, 4P 469 355 25
UAN32-50 / C frame, 3P 579 355 25
UAN32-50 / C frame, 4P 749 355 25
| UAN/UAS fixed type, panel cutting size - fixed type |
ACB
Air Circuit Breaker_41
Real panel cutting size
Model A B C
UAN06-20 / UAS06-16 / A frame, 3P 329 268 70
UAN06-20 / UAS06-16 / A frame, 4P 414 268 70
UAN06-40 / UAS20-32 / B frame, 3P 400 298 55
UAN06-40 / UAS20-32 / B frame, 4P 515 298 55
UAN32-50 / C frame, 3P 625 338 35
UAN32-50 / C frame, 4P 795 338 35
Front Side Rear (IP30)
(Test)26.5(Isol)11.5
292100
12-Ø
4
103.5 4-R5
122.
5
345
7.5
7.5
122.
511
5
103.5
25.6
20.460
33.1
330
A
CB
3132
Panel door
Rear panel (IP30)
(25) (323)
Operaing panel center
4
ACB center
3333
0
7513
214
4
Rear panel (IP30)
(95) (188)
A
CB
ACB center
Panel door
292
100
12-Ø
4
103.5 4-R5
122.
5
345
7.5
7.5
122.
511
5
103.5
25.6
Operaing panel center
| Panel cutting size - draw-out type |
/Air Circuit BreakerU-Series
42
ACB A B
Fixed type 120mm 50mm
Draw-outtype
Without Arc shield 120mm 50mm
With Arc shield 0mm 50mm
Insulating voltage D
[V] ≤ 600V 8mm
600V < [V] ≤ 1,000V 14mm
Technical Data
Minimum insulation distance at charging side
Insulation distance from arc
B B
A
AF Rated current(A)Fixed type Draw-out type
Internal resistance(㏁) Power consumption (W/3Phase) Internal resistance(㏁) Power consumption (W/3Phase)
UAN/UAS06-16 A frame
630 20 24 40 48
800 20 38 40 77
1,000 20 60 40 120
1,250 20 94 40 188
1,600 20 154 40 307
UAN20 A frame
630 15 18 30 36
800 15 29 30 58
1,000 15 45 30 90
1,250 15 70 30 141
1,600 15 115 30 230
2,000 13 156 27 324
UAN/UAS20-32 B frame
2,000 10 120 20 240
2,500 10 188 20 375
3,200 10 307 20 614
B frame UAN 40B
2,000 10 120 20 240
2,500 10 188 20 375
3,200 10 307 20 614
4,000 8 384 11 528
C frame UAN 40-50C4,000 8 384 11 528
5,000 8 600 11 825
D frame UAN 40-63D
4,000 6 288 9 432
5,000 6 450 9 675
6,300 5 595 7 833
B B
A
D
※ 1) Power consumption listed is maximum power consumption for each rated current, 50/60Hz, 3/4 pole.2) This is inner resistance value per pole.3) Power factor = 1.0
| Internal resistance and power consumption |
| Insulation distance |
ACB
Air Circuit Breaker_43
Item Altitude 2,000m 3,000m 4,000m 5,000m
Withstand voltage[V] 3,500 3,150 2,500 2,100Average insulating voltage[V] 1,000 900 700 600Max. operation voltage [V] 690 590 520 460Rectificated rated current [A] 1×In 0.99×In 0.96×In 0.94×In
Altitude
U-Series ACB is designed for operation at altitudes under 2,000m. At altitudes higher than 2,000m, change the ratings upon service condition.
Frame Ratedcurrent
Terminal busbar of ACB body
Applicable busbar size
Horizontal type Vertical type40°C 45°C 50°C 55°C 60°C 40°C 45°C 50°C 55°C 60°C
A frameUAN/UAS06-16
200A
15t×50mm×1EA
5t×50mm×1EA200A 200A 200A 200A 200A 200A 200A 200A 200A 200A
400A 400A 400A 400A 400A 400A 400A 400A 400A 400A 400A
630A5t×50mm×2EA
630A 630A 630A 630A 630A 630A 630A 630A 630A 630A10t×60mm×1EA
800A6t×50mm×2EA
800A 800A 800A 800A 800A 800A 800A 800A 800A 800A10t×60mm×1EA
1,000A8t×50mm×2EA 1,000A 1,000A 1,000A 1,000A 1,000A
1,000A 1,000A 1,000A 1,000A 1,000A6t×75mm×2EA - - - - -
1,250A8t×60mm×2EA
1250A 1250A 1250A 1250A 1250A1,250A 1,250A 1,250A 1,250A 1,250A10t×50mm×2EA
6t×75mm×3EA - - - - -
1,600A10t×60mm×2EA
1,600A 1,600A 1520A 1,480A 1,420A 1,600A 1,600A 1,580A 1,550A 1,550A8t×60mm×3EA
A frameUAN20 2,000A 15t×75mm×1EA 8t×75mm×3EA
- - - - - 2,000A 2,000A 1,940A 1,860A 1,860A10t×100mm×2EA
B frameUAN/UAS06-16
630A
20t×75mm×1EA
5t×50mm×2EA630A 630A 630A 630A 630A 630A 630A 630A 630A 630A
10t×60mm×1EA
800A6t×50mm×2EA
800A 800A 800A 800A 800A 800A 800A 800A 800A 800A10t×60mm×1EA
1,000A8t×50mm×2EA 1,000A 1,000A 1,000A 1,000A 1,000A
1,000A 1,000A 1,000A 1,000A 1,000A6t×75mm×2EA - - - - -
1,250A8t×60mm×2EA
1,250A 1,250A 1,250A 1,250A 1,250A1,250A 1,250A 1,250A 1,250A 1,250A10t×50mm×2EA
6t×75mm×3EA - - - - -
1,600A10t×60mm×2EA
1,600A 1,600A 1,600A 1,600A 1,600A 1,600A 1,600A 1,600A 1,600A 1,600A8t×60mm×3EA
2,000A8t×75mm×3EA 2,000A 2,000A 2,000A 2,000A 2,000A
2,000A 2,000A 2,000A 2,000A 2,000A10t×100mm×2EA - - - - -
2,500A10t×75mm×3EA
2,500A 2,500A 2,500A 2,400A 2,300A 2,500A 2,500A 2,500A 2,500A 2,500A8t×75mm×4EA
B frameUAN32 3,200A 20t×90mm×1EA 10t×100mm×3EA - - - - -
3,200A 3,200A 3,120A 3,050A 3,050A10t×75mm×4EA 3,200A 3,200A 3,100A 3,000A 2,900A
B frameUAN40
4,000AHorizontal
15t×100mm×2EA 10t×100mm×4EA4,000A 4,000A 3,900A 3,800A 3,640A - - - - -
10t×125mm×3EA4,000AVertical
15t×125mm×2EA 10t×100mm×4EA- - - - - 4,000A 4,000A 3,950A 3,800A 3,800A
10t×125mm×3EA
C frameUAN32-50
3,200A20t×125mm×2EA
10t×100mm×3EA 3,200A 3,200A 3,100A 3,000A 2,900A 3,200A 3,200A 3,100A 3,000A 3,000A4,000A 10t×100mm×4EA 4,000A 4,000A 3,920A 3,860A 3,800A 4,000A 4,000A 3,960A 3,900A 3,900A5,000A 10t×125mm×4EA 5,000A 5,000A 4,900A 4,800A 4,700A 5,000A 5,000A 4,950A 4,900A 4,900A
C frameUAN40-63
4,000A20t×125mm×2EA
10t×100mm×4EA 4,000A 4,000A 4,000A 4,000A 4,000A 4,000A 4,000A 4,000A 4,000A 4,000A5,000A 10t×125mm×4EA 5,000A 5,000A 4,900A 4,820A 4,750A 5,000A 5,000A 4,950A 4,870A 4,870A6,300A 10t×150mm×4EA 6,300A 6,300A 6,170A 6,040A 5,900A 6,300A 6,300A 6,220A 6,160A 6,160A
| Rectification of rated current |
/Air Circuit BreakerU-Series
44
| Derating table |
A frame
Switchboard compositionconnection type
Applicable ACB UAN/UAS06-08 UAN/UAS10Busbar dimensions (mm) 2EA x 50 x 6 2EA x 50 x 8
Ventilated switchboard (IP31)
Area of inlet vents: 350cm2
Area of outlet vents: 350cm2
Ta=35°C
4 800↓
3 800↓ 800↓ 1,000
2 800↓ 800↓ 800↓ 1,000 1,000
1 800↓ 800↓ 800↓ 800↓ 800↓ 1,000 1,000 1,000 1,000
Ta=45°C
4 800↓
3 800↓ 800↓ 1,000
2 800↓ 800↓ 800↓ 1,000 1,000
1 800↓ 800↓ 800↓ 800↓ 800↓ 1,000 1,000 1,000 1,000
Ta=55°C
4 800↓
3 800↓ 800↓ 1,000
2 800↓ 800↓ 800↓ 1,000 1,000
1 800↓ 800↓ 800↓ 800↓ 800↓ 1,000 1,000 1,000 1,000
Non ventilated switchboard(IP41/54) Ta=35°C
4 800↓
3 800↓ 800↓ 1,000
2 800↓ 800↓ 800↓ 1,000 1,000
1 800↓ 800↓ 800↓ 800↓ 800↓ 1,000 1,000 1,000 1,000
Ta=45°C
4 800↓
3 800↓ 800↓ 1,000
2 800↓ 800↓ 800↓ 1,000 1,000
1 800↓ 800↓ 800↓ 800↓ 800↓ 1,000 1,000 1,000 1,000
Ta=55°C
4 800↓
3 800↓ 800↓ 1,000
2 800↓ 800↓ 800↓ 1,000 1,000
1 800↓ 800↓ 800↓ 800↓ 800↓ 1,000 1,000 1,000 1000
Ambient temperature outside of the switchboard: Ta (IEC 60439-1)
4321
H
D W
H
D W
H
D W
H
D W
※ H: 2,300mm, W: 800mm, D: 900mm
Technical Data
ACB
Air Circuit Breaker_45
Switchboard compositionconnection type
Applicable ACB UAN/UAS12 UAN/UAS16Busbar dimensions (mm) 2EA x 75 x 6 2EA x 60 x 10
Ventilated switchboard (IP31)
Area of inlet vents: 350cm2
Area of outlet vents: 350cm2
Ta=35°C
4
3 1,250 1,000
2 1,250 1,250 1,600 1,000 1,000
1 1,250 1,250 1,250 1,250 1,600 1,600 1,600 1,000 1,000
Ta=45°C
4
3 1,250 1,000
2 1,250 1,250 1,600 1,000 1,000
1 1,250 1,250 1,250 1,250 1,600 1,600 1,600 1,000 1,000
Ta=55°C
4
3 1,250 1,000
2 1,250 1,250 1,470 1,000 1,000
1 1,250 1,250 1,250 1,250 1,500 1,600 1,600 1,000 1,000
Non ventilated switchboard(IP41/54) Ta=35°C
4
3 1,250 1,000
2 1,250 1,250 1,600 1,000 1,000
1 1,250 1,250 1,250 1,250 1,600 1,600 1,600 1,000 1,000
Ta=45°C
4
3 1,250 1,000
2 1,250 1,250 1,500 1,000 1,000
1 1,250 1,250 1,250 1,250 1,480 1,600 1,600 1,000 1,000
Ta=55°C
4
3 1,250 1,000
2 1,250 1,250 1,400 1,000 1,000
1 1,250 1,250 1,250 1,250 1,400 1,520 1,500 1,000 1,000
H
D W
H
D W
H
D W
H
D W
Ambient temperature outside of the switchboard: Ta (IEC 60439-1)
4321
※ H: 2,300mm, W: 800mm, D: 900mm
/Air Circuit BreakerU-Series
46
Switchboard compositionconnection type
Applicable ACB UAN/UAS201) UAN/UAS25 UAN/UAS32 UAN40Busbar dimensions (mm) 2EA x 75 x 10 3EA x 75 x 10 4EA x 75 x 10 4EA x 75 x 10
Ventilated switchboard (IP31)
Area of inlet vents: 350cm2
Area of outlet vents: 350cm2
Ta=35°C
4
3 2,000
2 2,000 2,000 2,000 2,400 2,500 3,100 3,200 3,400 3,750
1
Ta=45°C
4
3 2,000
2 2,000 2,000 2,000 2,300 2,400 2,900 3,100 3,200 3,550
1
Ta=55°C
4
3 2,000
2 2,000 2,000 2,000 2,200 2,300 2,700 2,900 3,000 3,300
1
Non ventilated switchboard(IP41/54) Ta=35°C
4
3 2,000
2 2,000 2,000 2,000 2,115 2,275 2,650 2,850 3,040 3,320
1
Ta=45°C
4
3 1,900
2 1,900 1,960 1,960 2,000 2,150 2,550 2,700 2,880 3,120
1
Ta=55°C
4
3 1,780
2 1,800 1,920 1,920 1,900 2,020 2,370 2,530 2,720 2,960
1
Ambient temperature outside of the switchboard: Ta (IEC 60439-1)
4321
4321
4321
4321
| Derating table |
B frame
H
D W
H
D W
H
D W
H
D W
※ - H: 2,300mm, W: 800mm, D: 900mm1) UAN20 A frame type is also applicable.
Technical Data
ACB
Air Circuit Breaker_47
Switchboard compositionconnection type
Applicable ACB UAN40 (C) UAN50 (C) UAN40 (D) UAN50 (D) UAN63 (D)Busbar dimensions (mm) 4EA x 100 x 10 4EA x 125 x 10 4EA x 100 x 10 4EA x 125 x 10 4EA x 150 x 10
Ventilated switchboard (IP31)
Area of inlet vents: 350cm2
Area of outlet vents: 350cm2
Ta=35°C
4
3
2 2,900 4,000 4,750 4,800 4,000 4,000 4,750 5,000 5,850 6,300
1
Ta=45°C
4
3
2 3,850 3,900 4,350 4,650 4,000 4,000 4,450 4,850 5,670 5,850
1
Ta=55°C
4
3
2 3,800 3,850 4,200 4,400 4,000 4,000 4,200 4,600 5,350 5,670
1
Non ventilated switchboard(IP41/54) Ta=35°C
4
3
2 3,800 3,900 4,200 4,550 4,000 4,000 4,400 4,650 5,350 5,000
1
Ta=45°C
4
3
2 3,650 3,800 3,950 4,250 4,000 4,000 4,100 4,400 5,040 5,350
1
Ta=55°C
4
3
2 3,550 3,650 3,700 4,050 3,900 3,950 3,850 4,150 4,730 5,040
1
Ambient temperature outside of the switchboard: Ta (IEC 60439-1)
4321
4321
4321
4321
4321
C/D frame
H
D W
H
D W
H
D W
H
D W
※ H: 2,300mm, W: 800mm, D: 900mm
/Air Circuit BreakerU-Series
48
Technical Data
| Discrimination table |
Upstream
Dow
nstr
eam
Recognition category
ACB
Model
UAN/UAS A frame UAN/UAS B frame UAN C frame
Rated current
(A)
630 800 1,000 1,200 1,250 1,600 2,000 2,500 3,200 4,000 4,000 5,000
Breaking capacity [Icu]
(kA r.m.s)85 85 85 85 85 85 100 100 100 100 100 100
MCB
HiBD63-NSB, C curve
1 4.5 T T T T T T T T T T T T
2 4.5 T T T T T T T T T T T T
5 4.5 T T T T T T T T T T T T
6 4.5 T T T T T T T T T T T T
10 4.5 T T T T T T T T T T T T
16 4.5 T T T T T T T T T T T T
20 4.5 T T T T T T T T T T T T
25 4.5 T T T T T T T T T T T T
32 4.5 T T T T T T T T T T T T
40 4.5 T T T T T T T T T T T T
HiBD63-NB, C, D curve
1 6 T T T T T T T T T T T T
2 6 T T T T T T T T T T T T
3 6 T T T T T T T T T T T T
4 6 T T T T T T T T T T T T
5 6 T T T T T T T T T T T T
6 6 T T T T T T T T T T T T
10 6 T T T T T T T T T T T T
13 6 T T T T T T T T T T T T
15 6 T T T T T T T T T T T T
16 6 T T T T T T T T T T T T
20 6 T T T T T T T T T T T T
25 6 T T T T T T T T T T T T
32 6 T T T T T T T T T T T T
40 6 T T T T T T T T T T T T
50 6 T T T T T T T T T T T T
63 6 T T T T T T T T T T T T
HiBD63HB, C, D curve
1 10 T T T T T T T T T T T T
2 10 T T T T T T T T T T T T
3 10 T T T T T T T T T T T T
4 10 T T T T T T T T T T T T
5 10 T T T T T T T T T T T T
6 10 T T T T T T T T T T T T
10 10 T T T T T T T T T T T T
13 10 T T T T T T T T T T T T
15 10 T T T T T T T T T T T T
16 10 T T T T T T T T T T T T
20 10 T T T T T T T T T T T T
※ Can be blocked all sectors. Can not be blocked.
•Breaking capacity: at AC380/415V
ACB
Air Circuit Breaker_49
Upstream
Dow
nstr
eam
Recognition category
ACB
Model
UAN/UAS A frame UAN/UAS B frame UAN C frame
Rated current
(A)
630 800 1,000 1,200 1,250 1,600 2,000 2,500 3,200 4,000 4,000 5,000
Breaking capacity [Icu]
(kA r.m.s)85 85 85 85 85 85 100 100 100 100 100 100
MCB
HiBD63hB, C, D curve
25 10 T T T T T T T T T T T T
32 10 T T T T T T T T T T T T
40 10 T T T T T T T T T T T T
50 10 T T T T T T T T T T T T
63 10 T T T T T T T T T T T T
HiBD125B, C, D curve
63 10 T T T T T T T T T T T T
80 10 T T T T T T T T T T T T
100 10 T T T T T T T T T T T T
125 10 T T T T T T T T T T T T
MCCB
UAB100C, R, S
5 30 T T T T T T T T T T T T
10 30 T T T T T T T T T T T T
15 30 T T T T T T T T T T T T
20 30 T T T T T T T T T T T T
30 30 T T T T T T T T T T T T
40 30 T T T T T T T T T T T T
50 30 T T T T T T T T T T T T
60 30 T T T T T T T T T T T T
75 30 T T T T T T T T T T T T
100 30 T T T T T T T T T T T T
UCB100R, S, H, L
15 50 T T T T T T T T T T T T
20 50 T T T T T T T T T T T T
30 50 T T T T T T T T T T T T
40 50 T T T T T T T T T T T T
50 50 T T T T T T T T T T T T
60 50 T T T T T T T T T T T T
75 50 T T T T T T T T T T T T
100 50 T T T T T T T T T T T T
125 50 T T T T T T T T T T T T
UCB250R, S, N, H, L
100 50 T T T T T T T T T T T T
125 50 T T T T T T T T T T T T
150 50 T T T T T T T T T T T T
175 50 T T T T T T T T T T T T
200 50 T T T T T T T T T T T T
225 50 T T T T T T T T T T T T
250 50 T T T T T T T T T T T T
※ Can be blocked all sectors. Can not be blocked.
•Breaking capacity: at AC380/415V
/Air Circuit BreakerU-Series
50
Technical Data
Upstream
Recognition category
ACB
Model
UAN/UAS A frame UAN/UAS B frame UAN C frame
Rated current
(A)
630 800 1,000 1,200 1,250 1,600 2,000 2,500 3,200 4,000 4,000 5,000
Breaking capacity [Icu]
(kA r.m.s)85 85 85 85 85 85 100 100 100 100 100 100
MCCB
UCB400R, S, N, H, L
250 100 T T T T T T T T T T T T
300 100 T T T T T T T T T T T T
320 100 T T T T T T T T T T T T
350 100 T T T T T T T T T T T T
400 100 T T T T T T T T T T T T
UCB630R, S, H, L
500 100 - T T T T T T T T T T T
630 100 - T T T T T T T T T T T
UCB800R, S, H, L
700 100 - - T T T T T T T T T T
800 100 - - T T T T T T T T T T
UPB100S, H, L, X
15 150 T T T T T T T T T T T T
20 150 T T T T T T T T T T T T
30 150 T T T T T T T T T T T T
40 150 T T T T T T T T T T T T
50 150 T T T T T T T T T T T T
63 150 T T T T T T T T T T T T
80 150 T T T T T T T T T T T T
100 150 T T T T T T T T T T T T
125 150 T T T T T T T T T T T T
UPB250R, S, N, H, L
125 150 T T T T T T T T T T T T
150 150 T T T T T T T T T T T T
175 150 T T T T T T T T T T T T
200 150 T T T T T T T T T T T T
225 150 T T T T T T T T T T T T
250 150 T T T T T T T T T T T T
UPB400S, H, L, X
250 150 T T T T T T T T T T T T
300 150 T T T T T T T T T T T T
320 150 T T T T T T T T T T T T
350 150 T T T T T T T T T T T T
400 150 T T T T T T T T T T T T
UPB630S, H, L, X
320 150 T T T T T T T T T T T T
350 150 T T T T T T T T T T T T
400 150 T T T T T T T T T T T T
500 150 - T T T T T T T T T T T
630 150 - T T T T T T T T T T T
※ Can be blocked all sectors. Can not be blocked.
Dow
nstr
eam
| Discrimination table |•Breaking capacity: at AC380/415V
www.hyundai-elec.com
HH
IS-WC
-LE-B74-00, 2013.2 D
esigned by JC C
reative
Head Office 1000, Bangeojinsunhwan-doro, Dong-gu, Ulsan, KoreaTel: 82-52-202-8101~8 Fax: 82-52-202-8100
Seoul 75, Yulgok-ro, Jongno-gu, Seoul, Korea (Sales & Marketing) Tel: 82-2-746-8519, 7492, 7620 Fax: 82-2-746-7441
Atlanta 6100 Atlantic Blvd. Suite 201, Norcross, GA30097, USATel: 1-678-823-7839 Fax: 1-678-823-7553
London 2nd Floor, The Triangle, 5-17 Hammersmith Grove London, W6 0LG, UKTel: 44-20-8741-0501 Fax: 44-20-8741-5620
Tokyo 8th Floor, Yurakucho Denki Bldg. 1-7-1 Yuraku-Cho, Chiyoda-Ku, Tokyo, 100-0006, JapanTel: 81-3-3212-2076, 3215-7159 Fax: 81-3-3211-2093
Osaka I-Room 5th Floor Nagahori Plaza Bldg. 2-4-8 Minami Senba, Chuo-Ku, Osaka, 542-0081, Japan Tel: 81-6-6261-5766~7 Fax: 81-6-6261-5818
Mumbai 5th Floor, East Quadrant, The IL & FS Financial Centre, Plot No. C-22, G-Block, Bandra-kurla Complex, Bandra(E), Mumbai 400 051, IndiaTel: 91-22-2653-3424 Fax: 91-22-2653-3429
Riyadh 2nd Floor, The Plaza, P.O Box 21840, Riyadh 11485, Saudi ArabiaTel: 966-1-462-2331 Fax: 966-1-464-4696
Dubai 205, Building 4, Emaar Square, Sheikh Zayed Road, Pobox 252458, Dubai, UAETel: 971-4-425-7995 Fax: 971-4-425-7996
Kuwait 15th Floor, Al Sour Tower, Al Sour Street, Al-Qiblah, KuwaitTel: 965-2291-5354 Fax: 965-2291-5355
Moscow World Trade Center, Ent. 3# 1902, Krasnopresnenskays Nab. 12, Moscow, 123610, RussiaTel: 7-495-258-1381 Fax: 7-495-258-1382
Madrid Paseo De La Castellana 216, Planta 0, 28046 Madrid, SpainTel: 34-91-732-0454, 733-6069 Fax: 34-91-733-2389
Sofia 1271, Sofia 41, Rojen Blvd., BulgariaTel: 359-2-803-3200, 3220 Fax: 359-2-803-3203
Montgomery 201 Folmar Parkway, Montgomery, AL 36105, USATel: 1-334-481-2000 Fax: 1-334-240-6869
Yangzhong No.9 Xiandai Road, Xinba Scientific and Technologic Zone, Yangzhong, Jiangsu, P.R.C. Zip: 212212, ChinaTel: 86-511-8842-0666, 0212 Fax: 86-511-8842-0668, 0231