ucg22-12 physical specification...capacity affect by temperature 40 c 103% 25 c 100% 0 c 86% design...
TRANSCRIPT
181.5 1
771
163.
51
166.
51
ISO9001
UCG22-1212V 22AHDeep Cycle
UCG22-12 Physical Specification
Part Number UCG22-12
Length 181.5 ± 2 mm
Width 77 ± 2 mm
Container Height 168.0 ± 2 mm
Total Height (with terminal) 168.0 ± 2 mm
Approx Weight 6.20 kg
SpecificationsNominal Voltage 12V
Nominal Capacity (10HR) 22AH
Terminal Type Standard Terminal F3
Container Material Standard Option ABS
Rated Capacity 20hr, 1.80V/cell, 25°C 22.85AH/1.1AH
10hr, 1.80V/cell, 25°C 22AH/2.06A
5hr, 1.75V/cell, 25°C 18.0AH/3.6A
3hr, 1.75V/cell, 25°C 16.32AH/5.44A
1hr, 1.60V/cell, 25°C 13.3AH/13.3A
Max Discharge Current 300A (5s)
Internal Resistance Approx 15.0m
Discharge Characteristics
Operating Temp. Range
Discharge: -15 ~ 50°C
Charge: 0 ~ 40°C
Storage: -15 ~ 40°C
Nominal Operating Temp. Range
25 ± 3°C
Cycle Use
Initial Charging Current less than 6.0A. Voltage14.4 ~ 15.0 Temp. Coefficient -30mV/°C
Standby Use
No limit on Initial Charging Current Voltage13.5 ~ 13.8 Temp. Coefficient -20mV/°C
Capacity affect by Temperature
40°C 103%
25°C 100%
0°C 86%
Design Floating Life at 20°C 12 Years
Self Discharge Ultracell batteries may be stored for up to 6 months at 25°C(77°F) and then a refresh charge is required.For higher temperatures the time interval will be shorter.
Dimensions
F3 Terminal
1 Ultracell (UK) Ltd | Vesty Business Park, Vesty Road, Liverpool, L30 1NY, United KingdomTel: +44 (0) 151 523 2777 | Fax: +44 (0) 151 523 0855 | Email: [email protected]
Revised: 28 Aug 2015ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE
14 [0.551] 2 [0.079]
4.5
[0.1
77]
13[0
.512
]
6[0
.236
]
F.V/Time 10 min 15 min 20 min 30 min 45 min 1h 2h 3h 4h 5h 6h 8h 10h 20h
1.85V/cell
1.80V/cell
1.75V/cell
1.70V/cell
1.67V/cell
1.60V/cell
30.1 12.64
38.4 14.7
42.3 15.3
46.05 15.8
49.75 16.24 54 17
22.1
26.2
28.16
29.6
31.45 33.5
25.3
30.6
33.41
35.7
37.940.6
10.3
11.5
12.02
12.44
12.8513.3
6.4
6.95
7.22
7.5
7.718
5
5.35
5.44
5.6
5.836
4.03
4.3
4.4
4.51
4.664.81
3.26
3.51
3.6
3.7
3.83.92
2.85
3.06
3.14
3.2
3.283.35
2.33
2.46
2.52
2.55
2.592.61
1.94
2.06
2.07
2.1
2.142.16
1.09
1.1
1.11
1.13
1.141.15
15.9
18.8
19.53
20.35
21.422.62
F.V/ Tim e
1.8 5V/cell1.8 0V/cell1.7 5V/cell1.7 0V/cell1.6 5V/cell1.6 0V/cell
10min 15min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h20min54.6 46.5 41.0 29.8 23.8 19.4 12.1 9.45 7.67 6.25 5.49 4.48 3.74 2.13
68.9 55.3 47.8 34.7 27.5 21.6 13.1 10.1 8.15 6.69 5.86 4.75 3.96 2.14
74.8 59.8 51.0 35.9 28.4 22.5 13.6 10.3 8.32 6.86 6.01 4.83 4.00 2.16
80.3 63.4 53.3 37.2 29.4 23.1 14.1 10.5 8.52 7.01 6.13 4.89 4.03 2.20
86.1 67.0 56.3 39.0 30.0 23.8 14.4 11.0 8.79 7.20 6.26 4.96 4.11 2.22
91.9 70.8 59.4 40.8 31.0 24.5 14.8 11.2 9.03 7.40 6.38 5.00 4.15 2.23
ISO9001
UCG22-1212V 22AHDeep Cycle
Constant Current Discharge (Amperes) at 25°C
Constant Power Discharge (Watts) at 25°C
2 Ultracell (UK) Ltd | Vesty Business Park, Vesty Road, Liverpool, L30 1NY, United KingdomTel: +44 (0) 151 523 2777 | Fax: +44 (0) 151 523 0855 | Email: [email protected]
Revised: 28 Aug 2015ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE
Temperature Effects in Relation to Battery Capacity Effect of Temperature on Long Term Float Life
Discharge Characteristics Charging Characteristics
1 2 4 6 8 10 20 40 60 2 4 6 8 10 20
0.05C0.093C0.2C
0.4C0.6C
1C2C
min H
Discharge Time
Term
inal
Vol
tage
(V)
0Temperature 25 C
C= C208.0
9.0
10.0
11.0
12.0
13.0
0 4 8 12 16 20 24 28
Charging Time (hours)
32
(V/cell)(A)
0.02C
0C
0.04C
0.06C
0.08C
0.1C
%
20
40
60
80
100
120
CHARGEVOLUME
CHARGING CURRENT
CHARGING VOLTAGE
0.1CA-2.25V/cell 0Temperature(25 C
0
2.0
2.1
2.2
2.3
2.4
AFTER 50% DISCHARGE
AFTER 100% DISCHARGE
CHARGE VOLTAGE(Constant 2.25v/cell)
CHARGED VOLUME
CHARGING CURRENT
C=C20
25 3030
40
60
80
110
50
70
90
100
-20 -15 0 15 20-10 -5 5 10
C3C5C10
C1
C20
Battery temperature/
Avai
labl
e ca
paci
ty /
%
0.5
Battery temperature
2
5
10
12
14
Charging voltage2.25V/cell
Life
exp
ecta
ncy(
year
)
2068
0C3086
40104
50122 OF
Cycle Life in Relation to Depth of Discharge General Relation of Capacity VS. Storage Time
Acc.t o IEC 89 6-2 (25 0 0C / 77 F)
Number of Cycles
30
40
60
80
Ext
ract
ed c
apac
ity in
%
20
10
50
70
90
100
400 800 120 0 160 0 200 0 240 0 280 0 320 0 360 0 400 0 0 5 10 15 20 25
Storage time in month
40
20
40
60
80
100
120
30 20
10
Residual average capacity in % of C 20
Avai
labl
e ca
paci