iMODULE - RAD - ING - Manuale - 1507.1

User's manual

iMODULE

Remote Control via Wi-Fi or GSM

2iMODULE - RAD - ING - Manuale - 1507.1

iMO

DU

LE_EN

TABLE OF CONTENTS

TABLE OF CONTENTS

1. INSTALLER SECTION 3

1.0.1. INSTALLER REGISTRATION 41.0.2. REGISTERING A NEW USER 41.0.3. HOW TO CONFIGURE THE PARAMETERS OF THE NEW UNIT 51.0.4. WIRING 71.0.5. CONFIGURATION OF IMODULE GSM VERSION 91.0.6. CONFIGURATION OF IMODULE WI-FI VERSION 10

2. USER SECTION 11

2.0.1. APP IMODULE 122.0.2. LOCAL-CONTROLLER 132.0.3. RECEIVER IMODULE 14

The operations of installation, described in this section,

must be performed by qualified personnel only, who has

technical expertise in the field required to installation and

maintenance of the parts of the heating and DHW production

systems for civil and industrial buildings as provided in Art.

3 of Min. Decree no. 37 dated 22.01.2008.

1. INSTALLER SECTION

4iMODULE - RAD - ING - Manuale - 1507.1

1 Installazione_iMO

DU

LE_v.1502_EN

2. INSTALLATION

INSTA

LLER

1.0.1. INSTALLER REGISTRATION

› Open the page ‘http://www.imodule.it/’;

› Click on “Registration Form”;

› Type in the page the following data:

· Installer's Name;

· Installer's Surname;

· Installer's Email Address;

· Choose a password;

· Installer's Address;

· Installer's mobile phone number (with international dialling code);

· Country;

· VAT number (11 characters);

· Captcha code.

› Press "Send".

› To confirm the registration, the installer must click on the link received by email;

› after confirmation, the installer receives a second email with a summary of login credentials and an attachment with the instructions for accessing the technical panel of the iModule APP.

1.0.2. REGISTERING A NEW USER

› Open the page ‘http://app.imodule.it/admin’;

› Enter the installer login credentials and click on "Login".

› The list of registered users (if any) will be displayed.

› To add a new User click on “New User/Boiler”.

› Enter the information regarding the new iModule unit to register:

· UserName and Password (that will be used by the user to log in to iMODULE APP);

· Name and Surname of system/iModule owner;

· Serial number of the iModule (without the zeros before the digit, for a serial number 00000168 you will write 168); the serial number is specified in the iModule unit, on the label above connector 'A' and below connector 'C' (see fig. 3 in chapter 'WIRING' );

· the phone number of the SIM card inserted in the iModule (only for iModule in GSM version);

· the place (province) of the iModule unit.

› Once you have entered the data, click on “Save”.

› Return to the home page, in the list of users, where is displayed the new iModule registered.

INSTALLATION

5iMODULE - RAD - ING - Manuale - 1507.1

1 Installazione_iMO

DU

LE_v.1502_EN1 Installazione_iM

OD

ULE_v.1502_EN

2. INSTALLATION

INSTA

LLER

1.0.3. HOW TO CONFIGURE THE PARAMETERS OF THE NEW UNIT

To configure the parameters of the new unit click on the adjustable spanner icon (see fig. 1).

fig. 1

fig. 2

6iMODULE - RAD - ING - Manuale - 1507.1

1 Installazione_iMO

DU

LE_v.1502_EN

2. INSTALLATION

INSTA

LLER

OPEN-THERM PROTOCOL CONFIGURATION

Use the parameter “OT Protocol version” (see fig.2) to configure the iModule based on the version of the Open-Therm Protocol used by the boiler:

› 0 = for boilers with electronic printed circuit board NORDGAS;

› 1 = for boilers with electronic printed circuit board HONEYWELL;

› 2 = non applicable.

CONFIGURATION OF STANDARD/DST TIME

You can switch from standard time to daylight saving time (and vice versa), using the parameter "DST change" (see figure 2) and modify the time of the iModule by one hour, according to the following convention:

› 0 = no change to current iModule time;

› 1 = add one hour to current iModule time;

› 255 = remove one hour from current iModule time.

TIME ZONE CONFIGURATION

You can manage all of the time zones from -12 hours to +14 hours, in relation to UTC coordinated universal time, with a resolution of half an hour.

The time zone of the iModule is set using the parameter "Time Zone" (see fig.2), within its his range [104÷156], according to the following rule:

· value of parameter “Time Zone” = 128 + difference of iModule time in relation to UTC time, multiplied by 2.

Examples of Time Zones:

UTC Time (Time Zone 0) = set “Time Zone” = 128;

Western Europe Time (Time one 1) = set "Time Zone" = 130;

India Time (Time Zone +5.5) = set “Time Zone” = 139;

Examples by City:

Paris/Rome = UTC Time + 1 = set “Time Zone” = 130;

London = UTC Time = set “Time Zone” = 128;

Moscow = UTC Time + 3 = set “Time Zone” = 134;

Kiev = UTC Time +2 = set “Time Zone” = 132;

Tehran = UTC Time +3.5 = set “Time Zone” = 135.

OPEN-THERM (OT) CONFIGURATION OR ROOM THERMOSTAT (RT)

For iModule systems connected to Open-Therm boilers (configuration–OT), set the parameter “Connection Type (OT/RT)” = 0;

For iModule systems connected to Room Thermostat boilers (configuration–RT), set the parameter “Connection Type (OT/RT)” = 1;

7iMODULE - RAD - ING - Manuale - 1507.1

1 Installazione_iMO

DU

LE_v.1502_EN1 Installazione_iM

OD

ULE_v.1502_EN

2. INSTALLATION

INSTA

LLER

1.0.4. WIRING

Install the Local-Controller within the home, for example in the same position as the previous programmable thermostat/remote controller.

Install the iModule in any place inside the house (house, cellar, boiler room, under the stairs… ), with a good GSM signal (for iModule in GSM version) or in the vicinity of the WI-FI Router/Switch (for iModule in Wi-Fi version);

Once you have installed the Local-Controller and the iModule, carry out the following electrical connections (see fig.3):

· Open-Therm connection between iModule and Local-Controller (2 wires);

· Connection between the iModule and the Boiler (2 wires) via Open-Therm or Room Thermostat Relay;

· iModule connection to the power supply network (230VAC).

KEYConnector A (Power supply):

· N - Neutral point of power cord (mains voltage 230 VAC, 50 Hz);

· L - Phase of power cord (mains voltage 230 VAC, 50 Hz);

· G - Grounding point of power cord (mains voltage 230 VAC, 50 Hz);

Connector B (for Room Thermostat versions only):

· T1 and T2 should be connected to the boiler to activate the heating request via the Room Thermostat relay.

Connector C (Open-Therm connections): · B1 and B2 should be connected to Open-

Therm bus of the boiler (only for boilers with Open-Therm configuration);

· R1 and R2 should be connected to the Local Controller.

fig. 3

8iMODULE - RAD - ING - Manuale - 1507.1

1 Installazione_iMO

DU

LE_v.1502_EN

2. INSTALLATION

INSTA

LLER

WIRING DIAGRAM OF OPENTHERM BOILER

WIRING DIAGRAM OF ROOM THERMOSTAT BOILER

fig. 4

fig. 5

9iMODULE - RAD - ING - Manuale - 1507.1

1 Installazione_iMO

DU

LE_v.1502_EN1 Installazione_iM

OD

ULE_v.1502_EN

2. INSTALLATION

INSTA

LLER

1.0.5. CONFIGURATION OF IMODULE GSM VERSION

WARNINGUse only SIM card “2G” type “DATA” or “OPTION + DATA” (the SIM cards “3G” are not supported like

in the case of telephone provider TRE).

To insert the SIM card into the iModule see fig.6.

Send an SMS to the telephone number associated to the SIM card inserted in the iModule with the following format:

APN:xxx# (instead of ‘xxx’ insert the APN of the operator of the SIM card inserted in the iModule).

Below are some examples of APN for Italian operators:

TIM = ibox.tim.it

VODAFONE = mobile.vodafone.it

WIND = internet.wind

Example of SMS to send to the iModule:

APN:internet.wind#

fig. 6

10iMODULE - RAD - ING - Manuale - 1507.1

1 Installazione_iMO

DU

LE_v.1502_EN

2. INSTALLATION

INSTA

LLER

1.0.6. CONFIGURATION OF IMODULE WI-FI VERSION

Power the iModule unit (via connector A, see fig.3 in chapter ‘WIRING’);

a Wi-Fi network called “iModule_WiFi” will be activated for 10 minutes; the network can be accessed without password;

Connect a Wi-Fi device (PC/Laptop/Tablet/Smartphone) to “iModule_WiFi” network;

Open a Web-Browser in the Wi-Fi device (recommended Browsers: Internet Explorer©, Mozilla Firefox©, Safari©) and select the web page: http://captiveportal.net;

If the web page ‘http://captiveportal.net’ does not open promptly, we suggest you disable the Proxy server, where applicable (check the connection options or browser settings);

Enter the data requested in the following fields (fig.7):

› Insert miniAP PassKey: nordgas

› Insert the SSID: name of Wi-Fi network to which the iModule will connect

› Insert the PSK: name of Wi-Fi network to which the iModule will connect

› Ignor the following 4 fields “Insert Static IP Address”, “Insert Static NetMask”, “Insert Static GW Address” and “Insert Static DNS Address”

› Turn on/off DNS/DHCP: select “ON”

› Choose Auth Type: select “Open System”

› Choose Auth: select one of the following options based on the safety protocol of the Wi-Fi network to which the device will connect:

· “WPA/WPA2” (with password);

· “WEP” (with password);

· “Open” (without password) for free Wi-Fi networks;

› Choose Mode: select Station;

› Finally, press Press “GO!”.

After a few seconds, the “iModule_WiFi” network is disabled by the iModule unit via the dedicated automatic disable function of the Wi-Fi device;

On the APP iModule, wait for max 3/5 minutes and check that the room temperature displayed was updated.

NOTE: should it be necessary to repeat the Wi-Fi setup (for example when you need to change one or more parameters of the Wi-Fi network to connect), cut off power to the iModule and repeat the configuration procedure.

fig. 7

the operations described in this section are addressed to

all those who will use the machine. The machine must be

used and accessed only by qualified operators that fully

read and understood the User section, paying particular

attention to the warnings.

2. USER SECTION

12iMODULE - RAD - ING - Manuale - 1507.1

3 AP

P iM

OD

ULE_EN

2. USE

USER

The iModule consists of:

› APP iMODULE installed on Smartphone and Tablet;

› Local-Controller (with room temperature sensor);

› Receiver iModule (in GSM or Wi-Fi version).

2.0.1. APP IMODULE

The APP iMODULE allows you to control the boiler connected to the Receiver iModule via your personal electronic device (Tablet and Smartphone).

Download the APP iMODULE for iOS (Apple iPhone/iPad) and Android for free easily, by scanning the QR (quick response) code below:

Or find the APP “iMODULE” directly in:

· App Store for iOS (Apple iPhone/iPad)

· Google Play for Android.

Once you have installed the APP iMODULE you can access the DEMO version (username and password not required), to test the interface and the control logic of the system without being connected to any real system.

Log in using the credentials provided by the Installer of you unit.

In he login page, you can select the application language from the following:

· English

· Italian

· Czech

· Polish

· Russian

· Ukrainian

You can also use the APP iMODULE from the browser entering the access credentials in the web page ‘http://app.imodule.it/home’. For quick access, scan the QR (quick response) code below:

USE

13iMODULE - RAD - ING - Manuale - 1507.1

3 Local-Controller_EN

3 Local-Controller_EN

2. USE

USER

2.0.2. LOCAL-CONTROLLER

The Local–Controller unit is equipped with a sensor that measures the room temperature displayed on the APP iMODULE.

The Local–Controller allows the User to set, in MANUAL mode, the desired room temperature using the adjustment dial.

KEY OF USER INTERFACE (SEE FIG.1)

1. Dial: used to set the room temperature within the range from 10°C to 30°C, valid fro MANUAL mode only;

2. Green LED:

· Steadily Lit: MANUAL mode enabled (boiler controlled by the Local-Controller).

· Flashing Slowly: AUTOMATIC mode enabled (boiler controlled by the APP iMODULE).

· Flashing Quickly: MANUAL mode enabled (power has been cut off to Receiver iModul, the boiler is controlled directly by the Local-Controller);

3. Push button: hold it down for three seconds to switch from AUTOMATIC to MANUAL mode and vice versa;

4. Red LED:

· Steadily Lit: failed communication between Open-Therm amd Receiver iModule or boiler;

· LED off: no failure;

· Flashing Slowly: Room sensor failure (on Local-Controller);

· Flashing Quckly: Receiver iModule failure (no communication to APP iModule).

·

USE

fig. 1

14iMODULE - RAD - ING - Manuale - 1507.1

3 iModule R

icevitore_EN

2. USE

USER

2.0.3. RECEIVER IMODULE

The Receiver iModule enables, in AUTOMATIC mode, exchanging data between the boiler and your personal electronic device (Tablet and Smartphone) controlled by the APP iMODULE.

KEY OF LED USER INTERFACE ‘1’ (FIG.1)

› Green LED Steadily Lit: AUTOMATIC mode enabled (boiler controlled by the APP iMODULE).

› Alternating Red and Green Flashing LED: the system is not configured (for WI-FI version, configure the WI-FI network to connect; for GSM version send an SMS to configure the APN).

› Green Slow Flashing LED (1 flash every 2.5 seconds): MANUAL mode enabled, boiler controlled by Local-Controller.

› Green Slow Flashing LED (1 flash every second): GSM/Wi-Fi communication in progress.

› Green Quick Flashing LED (5 flashes every second): Wi-Fi communication (mini access-point) in progress.

› Red Steadily Lit LED: GSM/Wi-Fi communication failure.

› Red Slow Flashing LED (1 flash every second): Local-Controller communication failure.

› Red Quick Flashing LED (5 flash every second): boiler communication failure (if configured as Open-Therm).

› LED off: iModule not powered.

If power has been cut off to Receiver iModul, the boiler is controlled directly by the Local-Controller in MANUAL mode.

USE

fig. 1