ufo lighting · 2020. 7. 21. · ufo lighting 3 installation the light source is powered from a 36v...

16
UFO LIGHTING FIBRE OPTIC & LED LIGHTING SYSTEMS REVISION: B1 MERCURY SLIMLINE LIGHT SOURCE USER GUIDE PLEASE READ THIS USER GUIDE BEFORE INSTALLING, OPERATING OR PERFORMING MAINTENANCE ON THE LIGHT SOURCE UNIT .

Upload: others

Post on 03-Feb-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

  • UFO LIGHTINGFIBRE OPTIC & LED LIGHTING SYSTEMS

    REVISION: B1

    MERCURY SLIMLINE LIGHT SOURCE

    USER GUIDE

    PLEASE READ THIS USER GUIDE BEFORE INSTALLING, OPERATING ORPERFORMING MAINTENANCE ON THE LIGHT SOURCE UNIT.

  • INTRODUCTION

    Thank you for purchasing this UFO light source.

    To ensure that the light source is set up optimally and gives a long service life, please read thisuser guide before installing, operating or performing any maintenance on the unit.

    Please keep this user guide for future reference.

    This light source is suitable for indoor use only unless it is situated in a weatherproof enclosure.

    MODELS COVERED BY THIS USER GUIDEUFO MER SL3000-MUFO MER SL3000-DMXUFO MER SL3000-0-10V

    MERCURY USER GUIDE2

    IMPORTANTThis product must be installed in accordance with the applicable installation code, by a personfamiliar with the construction and operation of the product, and the hazards involved.

    These light sources are not mains dimmable.

    The LED array in this light source is not replaceable. When it reaches end of life the whole unitmust be replaced.

    Type Y Attachment: If the external flexible cable or cord of this luminaire or associatedPSU/driver is damaged, it shall be exclusively replaced by the manufacturer or his service agentor a similar qualified person to avoid a hazard.

    Location: Do not locate this light source closer than 200mm from any flammable surface.

    Clearance / Ventilation: It is imperative that a gap of 200mm is left around the unit. This is toallow air to circulate and prevent overheating. The location must have free ventilation and mustnot have an ambient temperature higher than that specified for the luminaire.

    Mounting: This is a fixed luminaire. See mounting plate installation instruction on page 3 forfixing to surface.

    Warning: Never look directly into the luminaire LED light source.

    Warning: The luminaire should be positioned so that prolonged staring into theluminaire at a distance closer than 0.33m is not expected.

  • 3UFO LIGHTING

    INSTALLATION

    The light source is powered from a 36V Dc desktop PSU.

    The PSU caters for UK/European/other mains supplies using the relevant IEc power cordsupplied.

    POWER SUPPLY REQUIREMENTS

    MOUNTING PLATE INSTALLATIONThe light source is supplied with a separate mounting plate which is used for fixing to a wall orother surface. Four longer screws are also supplied for attaching the mounting plate to the lightsource body.

    To fix the mounting plate to the light source proceed as follows:

    1. Power off the light source and unplug the power socket, DMX connections and fibre harness,as applicable.2. Place unit upside-down on a surface.3. Remove the 4 screws which hold the rubber mounting feet in place, but leave the feet inposition.4. Place the mounting plate on top of the rubber feet and align the 4 screw holes with the holesin the rubber feet. Note that the mounting plate is a multi-function unit so there are holes in itfor other models of light sources as well as the Mercury.5. Insert the 4 longer screws supplied with the plate to tighten it to the light source body. Thefour rubber feet provide an anti-vibration effect between the 2 surfaces.6. You can then proceed to attach the mounting plate and light source to its surface.

    MER SL-3000M cONNEcTIONS MER SL-3000DMX / 0-10V cONNEcTIONS

    REAR CONNECTIONS

  • INSTALLATION

    MERCURY USER GUIDE4

    There are 3 connections required – the fibre port, the mains supply cable and the DMX controlcable. The fibre port should be connected first. connect and secure the fibre optic connectorinto the collar and secure using the M5 locking screw.

    connect the PSU to the Dc input jack socket on the light source, and connect the IEc plug to thePSU. Plug the mains plug into the electrical supply socket. Switch on power the led Indicatorwill illuminate and the light source is ready for use.

    Note:i. If there is no DMX signal, no light will be displayed.ii. If the DMX signal is disconnected whilst running, light will continue to illuminate, until thelight source is restarted.

    connect the DMX control cables to the Mini-XLR sockets on the rear of the light source. Therecommended plug for these sockets is Multicomp SVP556-TA. The pin out details for the plugsare shown below. Either socket may be used as DMX in or DMX out.

    CONNECTION - MER SL3000-DMX MODELS ONLY

    Note: UFO can supply converters for these light sources to allow them to be interfaced tostandard 3 pin XLR connectors or RJ45 connectors.

    There are 2 connections required – the fibre port and the mains supply cable. The fibre portshould be connected first. connect and secure the fibre optic connector into the collar andsecure using the M5 locking screw.

    connect the PSU to the Dc input jack socket on the light source, and connect the IEc plug to thePSU. Plug the mains plug into the electrical supply socket. Switch on power the led Indicatorwill illuminate and the light source is ready for use. If no light is produced consult theTROUBLESHOOTING section of this user guide.

    CONNECTION - MER SL3000-M MODELS ONLY

  • 5UFO LIGHTING

    INSTALLATION

    This is external current source dimming - the light source dimming input requires anexternal 0-10V source.

    There are three connections required - the fibre port, the mains supply cable and the 0-10Vcontrol cable. The fibre port should be connected first. connect and secure the fibre opticconnector into the collar and secure using the M5 locking screw.

    connect the PSU to the Dc input jack socket on the light source, and connect the IEc plug to thePSU. Plug the mains plug into the electrical supply socket. Switch on power the led Indicatorwill illuminate and the light source is ready for use.

    Note:i. if there is no 0-10V signal, no light will be displayed.ii. If dip switch 10 if off, no light will be displayed.iii. If the 0-10V signal is disconnected whilst running, light will not be displayed.

    connect up the 0-10V control cable to the mini XLR sockets on the rear of the light source. Therecommended plug for these sockets is the Multicomp SVP556-TA. The pin out details for theseplugs are shown below. Either socket may be used as 0-10V IN or 0-10V OUT

    CONNECTION - MER SL3000-0-10V MODELS ONLY

    Note: UFO can supply converters for these light sources to allow them to be interfaced tostandard 3 pin XLR connectors or RJ45 connectors.

  • OPERATION

    MERCURY USER GUIDE6

    USING THE LIGHT SOURCE - MERCURY M MODELS ONLYUnder normal operation the Mercury manual light source can be dimmed manually using thedimmer control on the rear of the unit.

    USING THE LIGHT SOURCE - MERCURY DMX MODELS ONLYThe DMX light sources can be dimmed remotely (single channel 0-255 – see table below) and canbe addressed manually.

    Single Channel Value 0 255

    Description LED off LED brightest

    Unless the address is specified on the purchase order, all light sources will be defaulted toaddress 001. connect the DMX controller to either of the Mini XLR sockets, and the light sourcecan now be dimmed. Additional slave (which are set to the same address) DMX light sources canbe linked together.

    To revert to Non DMX control operation, remove the DMX controller connection or switch the DMXcontroller OFF and the Light Source will default to full light output. There is no manual dimmingcontrol on the MERSL3000DMX.

    REVERTING A DMX LIGHT SOURCE TO MANUAL OPERATION MODE

    Disconnect the light source from the mains supply. Loosen the four screws and remove the topcover of the unit.

    The DMX address can be manually set using the 10 way DIP switch bank inside the unit asshown below and on the next page.

    SETTING THE DMX ADDRESS

  • 7UFO LIGHTING

    OPERATION

    SETTING THE DMX ADDRESS

    DMX B StartChannel # Dip Switches On

    DMX B StartChannel # Dip Switches On

    1 1 11 1,2,4

    2 2 12 3,4

    3 1,2 13 1,3,4

    4 3 14 2,3,4

    5 1,3 15 1,2,3,4

    6 2,3 16 5

    7 1,2,3 : :

    8 4 : :

    9 1,4 : ;

    10 2,4 511 1,2,3,4,5,6,7,8,9

  • OPERATION

    MERCURY USER GUIDE8

    USING THE LIGHT SOURCE - MERCURY 0-10V MODELS ONLYMercury 0-10V models allow the light output to be varied by applying a different voltage throughthe rear connectors. The following table represents light output percentage against approximatecontrol value input.

    Light OutputPercentage Voltage

    100% 7 - 10V

    90% 6.2V

    80% 5.8V

    70% 5.4V

    60% 5V

    50% 4.5V

    40% 3.9V

    30% 3.2V

    20% 2.3V

    10% 1.4V

    5% 1.1V

    2.5% 0.8V

    1.25% 0.4V

    0% 0.2V

    Note: The light source will not illuminate unless a 0-10V control voltage is in place.

  • 9UFO LIGHTING

    OPERATION

    MAINTENANCE LOG

    Date Maintenance Undertaken

    Note: A record of all maintenance MUST be kept in the table above, indicating what maintenancewas undertaken and when. This MUST be dated for warranty purposes.

  • TROUBLESHOOTING

    MERCURY USER GUIDE10

    PROCEDURES FOR ALL MODEL TYPES

    Problem Possible Cause(s) Remedy

    Unit is dead –no light outputand LED power

    indicator onPSU is not

    illuminated

    Mains supply off Check supply & reinstate

    Loose mains plugs Check plugs

    Plug fuse blown (UK) Check fuse. If blown, replace

    PSU failed Replace PSU

    Unit is dead –no light outputand LED power

    indicator onPSU is illumi-

    nated, but LEDindicator on

    Light source notilluminated

    PSU failed Replace PSU

    Unit is dead –no light outputbut LED power

    indicator isilluminated

    DMX dimming at minimum(for DMX version only)

    Adjust brightness oncontroller (increase value up

    from 0)

    DMX fault on controller orDMX cable

    Remove DMX XLR plug from rear of lightsource. Light source will default to full

    bright. Repair DMX controlleror cabling.

    LED Array failure Replace Light source

    Unit notresponding to

    DMXcommands

    Address incorrect Check the address set on unit matchesthe address set on the controller

    DMX cable fault

    Refer to manual diagram for correctwiring termination. Carry out continuity

    check.

    Swap DMX cable for knowngood cable

    Note: Please complete relevant troubleshooting procedures before returning the unit to us forfurther investigation.

  • 11UFO LIGHTING

    TROUBLESHOOTING

    Problem Possible Cause(s) Remedy

    0-10V Versionunit is dead -

    no light output -but LED

    indicator onlight source isilluminated.

    No 0-10V dimming to unit(0V= LED Off)

    Refer to manual diagram forcorrect termination.

    Carry out continuity check.Carry out voltage / polarity

    0-10V cable fault check0-10V cable fault

    Controller faultCarry out voltage / polarity

    check at controller.Repair / replace as necessary

    0-10V LED PCB failure Replace 0-10V PCB

    No 0-10V signalpresent

    Controller off or failed Check controller. Ensure 0-10V signal present

    0-10V cable faultyCarry out voltage and

    polarity check on mini XLRplug. Repair as necessary

    ADDITIONAL PROCEDURES FOR 0-10V MODELS ONLY

    Note: Please complete relevant troubleshooting procedures before returning the unit to us forfurther investigation.

  • TECHNICAL SPECIFICATIONS

    MERCURY USER GUIDE12

    Description Details

    Port connector size 30mm diameter

    Fibre type Glass / PMMA

    Mains Supply Voltage 100-240V AC, 50-60Hz, 1.8A

    PSU Output 36V DC, 1.66A, 60W max.

    LED Power 44W

    Min Ambient Temperature -10°C

    Max Ambient Temperature +45°C

    Fan 60mm crossflow, 12V

    Led Type White light

    DMX [specific models only] User addressable 1 channel dimming

    0-10V [specific models only] 0-10V DC receiving

    LED Life 50,000 hours typical

    CRI >90 (typical)

    Colour Temperature 2700°K or 3000°K

    Material Aluminium

    Finish Powder coated grey

    Dimensions (L x W x H) / Weight 176mm x 103mm x 75mm / 884g

  • 13UFO LIGHTING

    NOTES

  • NOTES

    MERCURY USER GUIDE14

  • 15UFO LIGHTING

    NOTES

  • DESIGN SPECIFY BUILD INSTALL

    United Kingdom • United States • Germany • Europe • UAE

    Universal Fibre Optics LtdHome Placecoldstream, TD12 4DTUnited Kingdom

    t. +44 (0)1890 883416www.ufo.lighting

    Universal Fiber Optic Lighting USA LLc6119A clark center AvenueSarasota, FL34238United States

    t. +1 941-343-8115www.fiberopticlighting.com

    Made in the United Kingdom

    UFO Licht GmBHDas Runde Haue GBRGewerbering Ost 5b93155 Hemau, Deutschland

    t. +49-(0)9491-95588-0www.ufo-licht.de