Page 1: ultrafast real-time digital autoradiography solutions€¦ · Courtesy of Dr. Alain Schweitzer, Novartis Linear dynamic range of the BetaIMAGER Key Benefit: Detect and quantify both

Acquire highly detailed images in a few hours

See the first results in minutes

Follow acquisition in Real-Time

ultrafast real-time

digital autoradiography solutions

Keep your research moving

Page 2: ultrafast real-time digital autoradiography solutions€¦ · Courtesy of Dr. Alain Schweitzer, Novartis Linear dynamic range of the BetaIMAGER Key Benefit: Detect and quantify both

- All commonly used beta emitting radioisotopes :3H, 14C, 32P, 35S, 125I

- Positron emitting (PET) isotopes

- Secondary beta emissions from several gamma emitting radioisotopes: 123I, 131I, 99mTc, 201Tl, 111In.

Courtesy of Janssen Research Foundation

Courtesy of Dr. Alain Schweitzer, Novartis

Linear dynamic range of the BetaIMAGER

Key Benefit:

Detect and quantify both high and low

sample concentrations

in a single data acquisition

Real-time autoradiography: distribution of D1 receptors

in rat brain striatum following tritiated ligand bindingKey Benefits:

See the irst results in minutes

See data accumulating in real-time

Avoid under/over exposure

1min 5min 15min 60min

High sensitivity & rapid image acquisition

accurate quantification

real-time digital autoradiography

Page 3: ultrafast real-time digital autoradiography solutions€¦ · Courtesy of Dr. Alain Schweitzer, Novartis Linear dynamic range of the BetaIMAGER Key Benefit: Detect and quantify both

Langlois and al,, 2001

200 x 250 mm maximum ield of view

Image multiple tissue sections

- up to 15 microscopy slides

- or a single larger sample (e.g.:TLC plate)

Optical zoom mode:

50 micron spatial resolution for smaller sample area Courtesy of A. Molatt and P. Mitchell, Pizer

FOV: 200 x 250 mm

FOV: 75 x 100 mm

QWBA rat section labeled with tritium

BetaIMAGERtm tRacer

Key Benefit:

Unmatched sensitivity cuts

your data acquisition time

from weeks to hours

Rat Brain sections labeled with a tritiated probe

12 hour data acquisition 12 week exposure

Key Benefit:

Detect ultra-low levels of bound

radiolabeled ligand

Use minimal amounts of radiolabeled

compound

Reduce radioactive waste

Minimize experimental costs

A study of NK3 receptor occupancy

The sensitivity of the BetaIMAGER TRACER system allows visuali-

zation and quantitative analysis of tritiated senktide binding to

NK3 receptors in a matter of hours when other autoradiography

methods would have taken months. Langlois and al., 2001

in situ hybridization

high throughput screening electrophoresis gels & blots

receptor binding studies

wide range of applications

turns autoradiography into a fast and easy routine

Large sample size & high resolution in one system

whole body imaging TLC plates

BetaIMAGER TRACERFilm Autoradiogram

Page 4: ultrafast real-time digital autoradiography solutions€¦ · Courtesy of Dr. Alain Schweitzer, Novartis Linear dynamic range of the BetaIMAGER Key Benefit: Detect and quantify both

excellent multi-label imaging capability

Multiplex various ligands and/or tracers in a single experiment

Separate and accurately discriminate between radioisotopes based on either differences

in energy (2 radioisotopes), or decay rates (up to 3 radioisotopes)

A fast and sensitive method for simultaneously determining the distribution of several

molecules in a single tissue section

Single

acquisition

Isotopic

separation Fusion

Establishing the histopathology of

myocardial infarct in a rat based model

111In-DTPA (Blue): Detects increased extracellular luid within ibrotic areas.

99mTc-Sestamibi (Green): Detects both the ischemic

and viable tissue surrounding the necrosis based on

levels of tissue perfusion.

18FDG (Red): Detects all tissue with an active glycolitic

metabolism

A S. Poussier and al, 2005

Ex vivo imaging of [11C]5 retention in 22 month old female tg/tg APP/ PS1 animals

following bolus injection of a [11C]5/[3H]1a cocktail. Yellow scale bars =100 μm.Yousei et al., 2010

For sections mounted on standard glass microscope slides

(imaging area is 24 x 32 mm)

Four position sample stage

Automated sequential data acquisition for all four samples

Spatial resolution of 10 μm can be achieved with 3H labelling

Possible combinations of energy based dual-detection radioisotope pairs include 3H/14C,

3H/35S, 3H/32P or 33P and for decay rate based multi-label combinations ,99mTc/ 111In/18F.

the high resolution digital autoradiography Solution

BetaIMAGERtm dFine

Co-localization of various receptors, ligands

Ex vivo imaging before/after in vivo μPET/μSPECT

microarraysreceptor binding assays

wide range of applications

Page 5: ultrafast real-time digital autoradiography solutions€¦ · Courtesy of Dr. Alain Schweitzer, Novartis Linear dynamic range of the BetaIMAGER Key Benefit: Detect and quantify both

BetaIMAGERtm

tRacer

BetaIMAGERtm

dFine

Technology

Detection Gaseous avalanche chamber Scintillating foil

Camera Intensiied CCD Camera Intensiied CCD Camera

Performance

Pixel Resolution 5µm 1µm

Spatial ResolutionFrom 50µm to 400µm depending on isotope,

zoom and sample

10µm to 25µm depending on

isotope

Field of View (FOV)

15 microscope slides: 200mm x 250 mm

6 microscope slides: 120mm x 160 mm

2 microscope slides: 75mm x 100 mm

Half microscope slide: 25 mm x 33 mm

24 mm x 32 mm

Linearity Linear response over a dynamic range of 104 Linear response over a dynamic range of 104

Multilabelling Capability

Energy Separation2 isotopes chosen from 3 different families of beta emitters : low energy (3H); medium energy

(14C, 35S, 33P, 99mTc,…) and high energy (32P, 18F, 11C,…)

Radioactive Decay

Separation

Up to 3 Beta emitting isotopes (including PET) with suficiently different radioactive decay rates can be imaged simultaneously and then separated

Cross talk (typical) 5 % for a 3H/14C separation 1 % for a 3H/14C separation

Sample Holder

Standard

Tritiated membranes

Non Tritiated membranes (14C, 35S, 33P,…)

15 microscope slides

4 position Automated microscope slide

changer

On request

Multi-isotopes sample holder

1 slide (127 x 178 mm) special sample holder

4 slides (120 x 170 mm) special sample holder

9 slides (51 x 76 mm) special sample holder

12 slides (38 x 76 mm) special sample holder

Softwares

Image Acquisition Beta-T Acquisition Software Beta-D Acquisition Software

Image Analysis M3Vision Analysis Software M3Vision Analysis Software

Data FormatsBitmap, JPEG, illustration & quantitative TIFFs,

ASCII

Bitmap, JPEG, illustration & quantitative TIFFs,

ASCII

System Requirements

Operating System Windows XP/7 Windows XP/7

Power Consumption Maximum: 250 W @ 230 V or 115 V Maximum: 50 W @ 230 V or 115 V

Dimensions 75x70x160 cm (WxDxH) 40x45x75 cm (WxDxH)

Weight 145 kg 35 kg

Technical Specifications

Page 6: ultrafast real-time digital autoradiography solutions€¦ · Courtesy of Dr. Alain Schweitzer, Novartis Linear dynamic range of the BetaIMAGER Key Benefit: Detect and quantify both

BIOSPACE LAB SA, France

11 Rue de Chenival, 95690 Nesles-la-Vallée, Francet +33 (0) 1 30 34 75 16f +33 (0) 1 30 34 72 21 [email protected]

BIOSPACE LAB Inc., USA

185 Alewife Parkway #410Cambridge, MA02138, USA t + 1 201 785 [email protected]

Scan here to visit now!

www.biospacelab.com

[email protected]

FOR MORE INFORMATION

VISIT OUR WEBSITE:

OR WRITE TO US