Page 1 of 28 Ultrasonic flow meter FLOMIC FL 103X

ELIS PLZEŇ a. s., Luční 15, P. O. BOX 126, 304 26 Plzeň, Czech Republic, tel.: +420/377 517 711, fax: +420/377 517 722 Es 90 345 K/d

Ultrasonic flow meter

FLOMIC FL 103X

Page 2: Ultrasonic flow meter FLOMIC FL 103X - tepso.ee

ELIS PLZEŇ a. s.

Design, Assembly and Service Manual

Page 2 of 28 Ultrasonic flow meter FLOMIC FL 103X

ELIS PLZEŇ a. s., Luční 15, P. O. BOX 126, 304 26 Plzeň, Czech Republic, tel.: +420/377 517 711, fax: +420/377 517 722 Es 90 345 K/d

Content

1. APPLICATION .................................................................................................................................................. 3

2. MEASUREMENT METHOD ............................................................................................................................. 3

3. TECHNICAL DESCRIPTION ........................................................................................................................... 3 3.1. Meter characteristics ..................................................................................................................................................... 3 3.2. Meter design ................................................................................................................................................................. 4

3.2.1. Compact version – basic dimensions ................................................................................................................... 4 3.2.2. Distributed version – basic dimensions ................................................................................................................ 4 3.2.3. Ultrasonic sensor unit ........................................................................................................................................... 5 3.2.4. Electronic unit ....................................................................................................................................................... 5 3.2.5. Separate sensor unit – terminal board ................................................................................................................. 7 3.2.6. Meter handling ...................................................................................................................................................... 8

4. TECHNICAL SPECIFICATIONS ...................................................................................................................... 9

5. PROJECT DESIGN AND METER INSTALLATION ...................................................................................... 10 5.1. Project design of systems including ultrasonic flow meters ......................................................................................... 10 5.2. Meter installation ......................................................................................................................................................... 13

5.2.1. General recommendations ................................................................................................................................. 13 5.2.2. Mechanical fitting ................................................................................................................................................ 14 5.2.3. Electrical connections ......................................................................................................................................... 14 5.2.4. Seals on meters ................................................................................................................................................. 16

6. OPERATIONAL START ................................................................................................................................. 18

7. OPERATION ................................................................................................................................................... 19 7.1. Reading the measured quantities from the meter display ........................................................................................... 19 7.2. Electrical outputs ......................................................................................................................................................... 19

7.2.1. Impulse output .................................................................................................................................................... 19 7.2.2. Current output .................................................................................................................................................... 20

7.3. Communication interface ............................................................................................................................................ 20 7.3.1. Communication via optical interface ................................................................................................................... 20 7.3.2. Communication via RS 232 ................................................................................................................................ 20 7.3.3. Communication via M-Bus.................................................................................................................................. 21

7.4. Communication modes ............................................................................................................................................... 21 7.4.1. Optical probe + PC (or notebook computer) ....................................................................................................... 21 7.4.2. RS 232 + PC (or notebook computer) ................................................................................................................ 21 7.4.3. RS 232 + GSM module ...................................................................................................................................... 22

7.5. Distributed meter version ............................................................................................................................................ 22 7.6. Error identification function .......................................................................................................................................... 23 7.7. Battery life and replacement ....................................................................................................................................... 23

8. CALIBRATION ............................................................................................................................................... 24

9. WARRANTY AND POST-WARRANTY SERVICES ...................................................................................... 24 9.1. Warranty services ....................................................................................................................................................... 24 9.2. Post-warranty services ................................................................................................................................................ 24

10. PRODUCT ORDERING .................................................................................................................................. 25

Page 3: Ultrasonic flow meter FLOMIC FL 103X - tepso.ee

ELIS PLZEŇ a. s.

Design, Assembly and Service Manual

Page 3 of 28 Ultrasonic flow meter FLOMIC FL 103X

ELIS PLZEŇ a. s., Luční 15, P. O. BOX 126, 304 26 Plzeň, Czech Republic, tel.: +420/377 517 711, fax: +420/377 517 722 Es 90 345 K/d

1. APPLICATION Battery-powered ultrasonic flow meters of the FLOMIC FL 103X type series are intended for measurements of

instantaneous flow rate and total volume of cold and hot water in flow-supply networks, heating industry and other industry branches, and archiving of the measured data. Measurement of flow pressure in piping is also possible. The FLOMIC FL 103X is characterized by high measurement accuracy and long-term stability over a wide range of measured values. The FLOMIC FL 103X flow meters do not require external power supply, do not include any moving parts or filters to prevent choking with mechanical impurities and, compared to conventional flow meters, have significantly lower hydraulic losses. The meters comply with the requirements of the EN 14154 standard.

2. MEASUREMENT METHOD The measurement method used is a single-beam impulse transit-time method based on determination of the time

needed for an ultrasonic impulse wave to cross the distance between two probes embedded in piping. Each of the probes functions as the sender and receiver in turns so that the ultrasonic wave travels in turns in and against the flow flow direction. This arrangement allows for effective elimination of errors due to asymmetry in the probe locations.

3. TECHNICAL DESCRIPTION

3.1. Meter characteristics

The FLOMIC FL 103X ultrasonic flow meter is an electronic device used to measure the flow rate in a fully flooded piping. It is manufactured and supplied in two versions: compact and distributed. The compact version, designated FL 1034, has the electronic unit attached directly onto the flow sensor housing. An optional accessory is equipment for flow pressure measurement within the range of 0 to 16 bar (instantaneous values) and data storage. The distributed meter version, designated FL 1035, has the electronic unit separated from the sensor and connected with it by means of a cable (max. length 5m). The electronic unit is accommodated in a box including a mounting base that can be fitted on a wall.

In the standard configuration, the meter software allows for measuring and display of the instantaneous flow rate and total volume of liquid passed through the meter since the volume counter was last reset. The meter is provided with a passive impulse output including an optocoupler. The impulse length is 50ms; on customer’s request, it can be set at 2ms.

Optional meter accessories include passive current output, pressure gauge function, data memory block, the RS 232 communication line (plus a GSM module, if required), the M-Bus communication interface, and meter data reading via an optical interface. On request, the meter can be supplied in a version suitable for use in drinking-flow supply systems. The separate sensor unit can be delivered with the protection class of IP 68.

Page 4: Ultrasonic flow meter FLOMIC FL 103X - tepso.ee

ELIS PLZEŇ a. s.

Design, Assembly and Service Manual

Page 4 of 28 Ultrasonic flow meter FLOMIC FL 103X

ELIS PLZEŇ a. s., Luční 15, P. O. BOX 126, 304 26 Plzeň, Czech Republic, tel.: +420/377 517 711, fax: +420/377 517 722 Es 90 345 K/d

3.2. Meter design

3.2.1. Compact version – basic dimensions

DN 32 40 50 65 80 100 125 150 200 250 300

L [mm] 360 360 360 360 360 360 360 360 450 450 450

S [mm] 230 240 250 265 280 310 340 370 430 490 550

D [mm] PN16/40 140 150 165 185 200 220/235 250/270 285/300 340/375 405/450 460/515

Weight [kg] 9 9 11.5 12 15.5 17 18.5/20.5 19.5/21.5 28.5/37.5 45.5/70.5 58.5/84.5

3.2.2. Distributed version – basic dimensions

The L and D dimensions are the same as shown for compact meter version (section 3.2.1).

136

ELECTRONICUNIT

ULTRASONICSENSOR

S

DN

removed

w arran ty

IMPULSE OUTPUT CONST. CURRENT OUTPUT

PRESSURE RANGE

PRESSURE

DN Ser. No.

l/imp

bar

mA

MPa

v oid if

o D

80

DN

UNITELECTRONIC

TERMINAL BOARDULTRASONIC

SENSOR

max. length 5m

removed

warranty

IMPUL SE O UTPUT CO NST . CURREN T O UTPUTPRESSURE RANG E

PRESSURE

DN Ser. No.

l/imp

ba rm A

MPa

void if

o D

Page 5: Ultrasonic flow meter FLOMIC FL 103X - tepso.ee

ELIS PLZEŇ a. s.

Design, Assembly and Service Manual

Page 5 of 28 Ultrasonic flow meter FLOMIC FL 103X

ELIS PLZEŇ a. s., Luční 15, P. O. BOX 126, 304 26 Plzeň, Czech Republic, tel.: +420/377 517 711, fax: +420/377 517 722 Es 90 345 K/d

3.2.3. Ultrasonic sensor unit

The ultrasonic sensor unit comprises a housing made of carbon or stainless steel with two flanges (size 11 according to EN 1092-1, or ANSI or JIS flanges) and two embedded ultrasonic probes. The measurement pipe and probes are made of stainless steel. The carbon-steel sensor housing is painted with the KOMAXIT E 2310 powder epoxy paint of light grey hue (RAL 7035). The rating plate attached to the sensor body includes the basic meter specifications including the sensor size (DN) and an arrow indicating flow direction – see the picture below.

3.2.4. Electronic unit The electronic unit including a battery are placed in an aluminium box with a plastic lid. The box is provided with a

special valve preventing moisture condensation inside the box and up to three grommets for cables of circular cross-section. The surface finish of the box is by paint of orange hue (RAL 1017).

Two M8 grommets are intended for cables of outside diameter 3.5 to 5mm to be connected to the selected output signal terminals. On delivery, these grommets are blinded. The third grommet (M12) is provided only in the case of the distributed meter version and is intended for the cable of diameter 6.5 to 8mm connecting the sensor and the remote electronic unit. The connecting cable is supplied attached to the electronic unit with the other end ready to be connected to the sensor terminal board. In the IP 68 design version of the sensor, the connecting cable is fixed to both the sensor and electronic units and cannot be disconnected.

The meter display is located under the transparent plastic cover. The push-button on the unit box is used to select the desired display mode: either instantaneous flow rate (in m3/hod or gallons per minute), the total fluid volume (in m3 or gallons) passed through the meter sensor since the volume counter was last reset, or the fluid pressure (in bar). The actual quantity displayed is indicated at the bottom line by the symbol . In the case of a meter failure condition, the respective error message (E1 through to E5) will be indicated by the same symbol - see the picture below. A recess in the unit box is for an optical probe to be applied onto the recessed surface to read the stored data. Also found under the box lid is the meter rating plate:

RATING PLATE ULTRASONIC PROBE

removed

warrantyvoid if

DIMENSION DN

SER.No.

CLASS EMC OPER ENVIROMENT

IMPULSE OUTPUT

CURRENT OUTPUT

PRESSURE RANGE

Q 2500; R200; U5/D3; P10

l/imp

mA

bar

PRESSURE MPa

3

FLOW DIRECTION

Page 6: Ultrasonic flow meter FLOMIC FL 103X - tepso.ee

ELIS PLZEŇ a. s.

Design, Assembly and Service Manual

Page 6 of 28 Ultrasonic flow meter FLOMIC FL 103X

ELIS PLZEŇ a. s., Luční 15, P. O. BOX 126, 304 26 Plzeň, Czech Republic, tel.: +420/377 517 711, fax: +420/377 517 722 Es 90 345 K/d

Plate showing the rated parameters in m3 and m3/hod

Plate showing the rated parameters in G and GPM

IMPORTANT NOTICE: Prior to operational start, check proper tightening of the grommets and blinding of the unused ones. It is important to protect the evaluating electronic against direct sunshine.

OPTICAL PROBERECESS FOR

PUSH-BUTTON

GROMMETS

PLASTICCOVER

BATTERY

VALVECONDENSATION

ALUMINIUMHOUSING

11/2011B

ATTER

YC

HA

NG

E OF

FLOMIC FL 1024IP 67 DC 3,6V

VALUE DISPLAYED

x10 x10

T0....90°C

MULTIPLIERE1 E2 E3 E4 E5 m m/h 3 3

ELIS PLZEN a.s.

DISPLAY

bar

RECESS FOR OPTICAL PROBE

PUSH-BUTTON

FLOMIC FL 1035

E2 E1 E4 bar E5 E3 G

DC 3,6VIP 67

ELIS PLZEN a.s.

DISPLAY

COVERPLASTIC

GROMMETS

BATTERY

VALVECONDENSATIONHOUSINGALUMINIUM

GPM CH

AN

GE

OF

BATTERY

11/2

011

VALUE MULTIPLIERDISPLAYED

x10 x10 4

T0....130°C

Page 7: Ultrasonic flow meter FLOMIC FL 103X - tepso.ee

ELIS PLZEŇ a. s.

Design, Assembly and Service Manual

Page 7 of 28 Ultrasonic flow meter FLOMIC FL 103X

ELIS PLZEŇ a. s., Luční 15, P. O. BOX 126, 304 26 Plzeň, Czech Republic, tel.: +420/377 517 711, fax: +420/377 517 722 Es 90 345 K/d

3.2.5. Separate sensor unit – terminal board In the case of the distributed version (FLOMIC FL 1035) of the flow meter, attached to the sensor housing is a

terminal board in an aluminium box with a sealed lid. The terminal box is provided with a M12 grommet for a cable of diameter 6.5 to 8mm, a valve preventing moisture condensation inside the box and four spring-loaded WAGO terminals to which the ultrasonic probes signals are brought. Connected to these terminals shall be the wires of the cable leading to the remote electronic unit. In the case of IP 68 design of the sensor unit, the cable interconnection between the sensor and the electronic unit is fixed by the manufacturer and cannot be dismantled; the sensor terminal board is imbedded with a sealing compound. In the meter version including a pressure gauge there are eight WAGO terminals (see section 5.2.3 – electrical connections of a distributed meter version).

CONNECTING CABLETO ELECTRONIC UNIT

GROMMET

WAGO TERMINALS

ALUMINIUMBOX

BOX

LID

CONDENSATIONVALVE

X1 4 3 2 1

X2 4 3 2 1

Page 8: Ultrasonic flow meter FLOMIC FL 103X - tepso.ee

ELIS PLZEŇ a. s.

Design, Assembly and Service Manual

Page 8 of 28 Ultrasonic flow meter FLOMIC FL 103X

ELIS PLZEŇ a. s., Luční 15, P. O. BOX 126, 304 26 Plzeň, Czech Republic, tel.: +420/377 517 711, fax: +420/377 517 722 Es 90 345 K/d

3.2.6. Meter handling The arrows indicate incorrect grips on the meter assembly. Do not lift the meter holding it by the electronic unit –

see the picture below:

The arrows indicate the correct grips on the meter assembly. To lift the meter, hold it by the flanges or meter body.

removed

warranty

IMPULSE OUTPUT CONST. CURRENT OUTPUT

PRESSURE RANGE

PRESSURE

DN Ser. No.

l/imp

barmA

MPa

void if

removed

warranty

IMPULSE OUTPUT CONST. CURRENT OUTPUT

PRESSURE RANGE

PRESSURE

DN Ser. No.

l/imp

barmA

MPa

void if

Page 9: Ultrasonic flow meter FLOMIC FL 103X - tepso.ee

ELIS PLZEŇ a. s.

Design, Assembly and Service Manual

Page 9 of 28 Ultrasonic flow meter FLOMIC FL 103X

ELIS PLZEŇ a. s., Luční 15, P. O. BOX 126, 304 26 Plzeň, Czech Republic, tel.: +420/377 517 711, fax: +420/377 517 722 Es 90 345 K/d

4. TECHNICAL SPECIFICATIONS Rated internal diameter DN 32 40 50 65 80 100 125 150 200 250 300 Minimum flow rate Q1

m3/h 0.2 0.313 0.5 0.788 1.25 2.0 2.5 3.13 6.35 10.0 15.87G/min 0.88 1.38 2.2 3.47 5.5 8.8 11 13.8 27.9 44.0 69.9

Transient flow rate Q2

m3/h 0.32 0.5 0.8 1.26 2.0 3.2 4.0 5.0 10.2 16.0 25.39G/min 1.41 2.2 3.52 5.55 8.8 14.1 17.6 22 44.7 70.4 111.8

Continuous flow rate

Q3 m3/h 16 25 40 63 100 160 200 250 400 630 1000

G/min 70.4 110 176 277 440 704 881 1101 1761 2774 4403

Overload flow rate

Q4 m3/h 20 31.25 50 78.75 125 200 250 312.5 500 787.5 1250

G/min 88 138 220 347 550 881 1101 1376 2201 3467 5504Suppressed flow rate QNEC

m3/h 0.04 0.07 0.1 0.17 0.29 0.5 0.79 1.16 1.89 3 4.6 G/min 0.18 0.3 0.44 0.75 1.28 2.2 3.48 5.1 8.3 13.2 20.2

Impulse output constant k i

l/imp 10 25 25 50 100 100 250 250 500 500 1000G/imp 2 5 5 10 15 15 50 50 100 100 200

Rated pressure РN 1.6 MPa, 4 MPa (classes MAP 16, MAP 40) Temperature class Compact meter version– T90 (0.1 ÷ 90°С),Distributed version– T130 (0.1 ÷ 130°С)Measurement precision In compliance with standard EN 14154 Ambient temperature 0 ÷ 50°С Display unit Single-line 8-character LC display

Power Li battery 3.6V/16Ah, type LS 33600, minimum lifetime 6 to 8 years Li battery 3.6V/3.6Ah, type LSH 14 light, lifetime 1 year (supplied on customer's request)

Flow-profile sensitivity class U5 and D3 Measurement range Q3/Q1 R200 Climatic & mechanical. Class C Electromagnetic Class E2 Measurement period 1 sec. Flange connections ČSN EN 1092-1, on request ANSI, JIS, AS Sensor body design Carbon or stainless steel Pressure gauge Measurement range 0 ÷ 16 bar Protection class IP 67 Pressure loss class Δ P10 (less than 0.1 bar at Q3) Outputs Passive impulse output U = 5 ÷ 30 V, Imax = 10 mA, impulse length 40 ms Optional accessories Passive current output 4 to 20mA, Umax = 24V Pressure gauge, measurement of pressure in piping within the range 0 to 16 bar Measurements in US Gallons Data storage/archiving facility Communication interface to RS 232 Stored data reading via a GSM module Optical interface including optical probe and ArchTerm program Communication interface to M-Bus Distributed meter version, maximum cable length 5m, max. temperature 150oC Protection class IP 68 design of separate sensor unit Drinking-flow version of meter (all-stainless-steel design) Flanges according to other than EN standards (ANSI, JIS)

Page 10: Ultrasonic flow meter FLOMIC FL 103X - tepso.ee

ELIS PLZEŇ a. s.

Design, Assembly and Service Manual

Page 10 of 28Ultrasonic flow meter FLOMIC FL 103X

ELIS PLZEŇ a. s., Luční 15, P. O. BOX 126, 304 26 Plzeň, Czech Republic, tel.: +420/377 517 711, fax: +420/377 517 722 Es 90 345 K/d

The threshold flow rate at which the meter starts to register and measure the fluid flow parameters is set at the manufacturing plant at QNEC corresponding to flow velocity of 20mm/sec. On customer’s request this value can be adjusted within the range of 0.1 to 25% Q4.

5. PROJECT DESIGN AND METER INSTALLATION

Compliance with standards ČSN EN 14 154-1, -2 -3 and strict observance of the recommendations in this Manual are required in all project-design work regarding application and installation of the FLOMIC FL 103X ultrasonic flow meters in flow-supply networks.

5.1. Project design of systems including ultrasonic flow meters

In flow supply and distribution systems, flow meters should be located so as to ensure maximum measurement precision. In the case of the FLOMIC meters, the lengths of the required straight piping sections on the input and output sides are at least 5xDN and 3xDN, respectively.

Minimum lengths of straight piping sections If there is any pump nearby, it should be located on the output side of the meter at the distance of at least 20xDN.

Pump placement

Ser. No.

PRESSURE RANGE

CURRENT OUTPUTIMPULSE OUTPUT CONST.

DN

PRESSURE MPal/imp

warranty

removedvoid if

mAbar

void ifremoved

IMPULSE OUTPUT CONST. PRESSURE

CURRENT OUTPUT

PRESSURE RANGE

DN Ser. No.

bar

MPa

warranty

mAl/imp

FLOW DIRECTIONFLOW DIRECTION

5 DN 3 DN 3 DN5 DN

Ser. No.

PRESSURE RANGECURRENT OUTPUTIMPULSE OUTPUT CONST.

DN

PRESSURE MPal/imp

warranty

removedvoid if

mAbar

FLOW DIRECTION

20 DN

Page 11: Ultrasonic flow meter FLOMIC FL 103X - tepso.ee

ELIS PLZEŇ a. s.

Design, Assembly and Service Manual

Page 11 of 28Ultrasonic flow meter FLOMIC FL 103X

ELIS PLZEŇ a. s., Luční 15, P. O. BOX 126, 304 26 Plzeň, Czech Republic, tel.: +420/377 517 711, fax: +420/377 517 722 Es 90 345 K/d

In the cases where full flooding of the piping cannot be guaranteed at all times, the meter sensor should be fitted in such piping section where these conditions will always be met.

Meter placement to ensure full flooding Should the meter need be installed in a vertical piping section, the flow flow direction shall be upwards.

Vertical sensor position

5DN

3DN

Ser. No.

PRESSURE RANGE

CURRENT OUTPUTIMPULSE OUTPUT CONST.

DN

PRESSURE MPal/imp

warranty

removedvoid if

mAbar

MPa

l/imp

warranty

remov

ed

void

if

mA

bar

DN

PRESSURE

Ser. N

o.

PRES

SURE RANGE

CURRENT O

UTPUT

IMPU

LSE

OUTPUT C

ONST.

FLOW D

IREC

TION

3 DN5 DN

FLOW DIRECTION

FLO

W D

IRECTIO

N

Ser

. N

o.

PRESS

UR

E R

AN

GE

CU

RR

EN

T O

UTPU

TIM

PULS

E O

UTPU

T CO

NS

T.

DN

PRESSU

RE

M

Pal/im

p

war

ranty

rem

oved

void

if

mA

bar

Page 12: Ultrasonic flow meter FLOMIC FL 103X - tepso.ee

ELIS PLZEŇ a. s.

Design, Assembly and Service Manual

Page 12 of 28Ultrasonic flow meter FLOMIC FL 103X

ELIS PLZEŇ a. s., Luční 15, P. O. BOX 126, 304 26 Plzeň, Czech Republic, tel.: +420/377 517 711, fax: +420/377 517 722 Es 90 345 K/d

To ensure reliable and accurate measurements under all circumstances, the measured fluid shall fill the internal cavity of the sensor at all times. Therefore the sensor should not be placed at the highest piping section or in a vertical piping section where the flow direction is downwards, in particular in cases where a piping outlet to open tanks is anywhere near.

Examples of incorrect sensor placement Otherwise there are no limitations regarding sensor position in piping; however, consideration should be given to the ease of reading the display data and access to the optical probe contact point (see the picture below).

The above recommendations regarding the meter/sensor placement and installation apply to both the compact and distributed meter versions.

Ser. No.

PRESSURE RANGE

CURRENT OUTPUTIMPULSE OUTPUT CONST.

DN

PRESSURE MPal/imp

warranty

removedvoid if

mAbar

Ser. N

o.

PR

ES

SU

RE R

AN

GE

CU

RR

EN

T O

UTPU

TIM

PU

LSE O

UTPU

T CO

NS

T.

DN

PRES

SU

RE

MPa

l/imp

warran

t y

removed

void if

mA

bar

FLOW DIRECTION

FLO

W D

IRECTIO

N

Page 13: Ultrasonic flow meter FLOMIC FL 103X - tepso.ee

ELIS PLZEŇ a. s.

Design, Assembly and Service Manual

Page 13 of 28Ultrasonic flow meter FLOMIC FL 103X

ELIS PLZEŇ a. s., Luční 15, P. O. BOX 126, 304 26 Plzeň, Czech Republic, tel.: +420/377 517 711, fax: +420/377 517 722 Es 90 345 K/d

5.2. Meter installation The meter installation shall be done in observance of the requirements in standard ČSN EN 14 154-2, chapter 5.

5.2.1. General recommendations IMPORTANT NOTICE! When the evaluating electronic is placed in outdoor environment, it is important to protect it against direct sunshine by a suitable shed. The electronic mustn't be placed in a closed box. In the basic arrangement of a compact flow meter (flow direction from left to right and the sensor installed into a horizontal piping section), the electronic unit is fitted onto the sensor body as shown in the following picture.

In the case of the flow direction from right to left, the electronic unit can be rotated with respect to the sensor body

by 180° in both ways. The unit can be rotated upon loosening the arresting screws M5 at the unit base using an Alien wrench, size 2.5mm. With commercial (invoicing) meters, the arresting screw is provided with a seal so that the position of the electronic unit cannot be modified.

FLOW DIRECTION

Lock screw

P

VIEW P

FLOW DIRECTION

Page 14: Ultrasonic flow meter FLOMIC FL 103X - tepso.ee

ELIS PLZEŇ a. s.

Design, Assembly and Service Manual

Page 14 of 28Ultrasonic flow meter FLOMIC FL 103X

ELIS PLZEŇ a. s., Luční 15, P. O. BOX 126, 304 26 Plzeň, Czech Republic, tel.: +420/377 517 711, fax: +420/377 517 722 Es 90 345 K/d

To prevent signal interference, the meter wiring shall be placed at least 25cm away from any live power cables. The interconnection between the meter sensor and the associated electronic unit (the distributed meter version) is made by a shielded cable with the shielding connected to the earth potential at the sensor terminal board. It is recommended that all output signals (the impulse, current and M-Bus outputs) be connected using shielded cables with the shielding connected to the earth potential on the side of the plant control system. The meter sensor shall also be carefully earthed. To do that, connect the grounding bolt on the sensor flange with the piping flanges using an earthing conductor of cross-section of at least 4mm2 .

5.2.2. Mechanical fitting The ultrasonic sensor shall be fitted into the flow piping across piping flanges matching the meter flanges 11

(ČSN EN 1092-1), or flanges according to other standards such as ANSI, JIS or AS.

5.2.3. Electrical connections

The compact meter version (FL 1034): the only connections to be made are bringing the output signal cables to the respective terminals on terminal board X1 in the electronic unit. The terminal board can be accessed upon removal of the plastic lid at the top of the unit box. The lid is secured in position by means of two M4 screws with hexagonal socket heads for Alien wrench size 2mm. At the bottom side of the plastic lid there are two slots 8mm wide where a flat tool can be inserted to help lift the lid from its position on the box. It is recommended to insert a screwdriver into one of the slots and slightly pry upwards. The locations of the slots are shown in the picture below. Prior to replacing the lid, apply a thin layer of glycerine or silicon oil on the sealing O-ring. When replacing the lid, the 3mm hole at the bottom side of the plastic lid should be fitted onto the guide pin of diameter 2.5mm press-fitted at the box bottom.

F L O M IC F L 1024IP 67DC 3,6V

Earthing conductor with green and yellow insulation

Page 15: Ultrasonic flow meter FLOMIC FL 103X - tepso.ee

ELIS PLZEŇ a. s.

Design, Assembly and Service Manual

Page 15 of 28Ultrasonic flow meter FLOMIC FL 103X

ELIS PLZEŇ a. s., Luční 15, P. O. BOX 126, 304 26 Plzeň, Czech Republic, tel.: +420/377 517 711, fax: +420/377 517 722 Es 90 345 K/d

(ext

erna

l pow

er s

uppl

y)

(ext

erna

l pow

er s

uppl

y)

Current output powersupply

power supplyImpulse output

Cur

rent

out

put

Com

mun

icat

ion

inte

rfac

e M

-BUS

Impu

lse

outp

ut

BOLTS HOLDING TOP COVER IN POSITION

OUTPUT TERMINALBOARD CONNECTIONS

Cur

rent

out

put

(ext

er.p

ower

sup

ply)

Impu

lse

outp

ut

(ext

er.p

ower

sup

ply)

U=10÷24V

1 2 3 4 5 6 7 8

FL 1034,FL 1035

M-B

US

/RX

M-B

US

/TX

1 32 4

-IM

P+

IMP

6 7 8

X2

-RS +RS

RX TX

-R

S +

RS

+I-I

9

X1

X15

5,5V

X1

RX TX

54321

FL 1034,FL 1035

Communication interface M-BUS

Communication interface RS 232

Imax.=

10 m

A

+22k 6V

SLOTS FOR INSERTION OF SCREWDRIVER

Com

mun

icat

ion

Communication interface RS 232Communication

interface M-BUS

RUN-IN PLUG

Not used

warrant

y

remove

d

void

of

remov

edwa

rranty

9

+IM

P

+I

-IM

P

-I +

I= 4

÷20 m

A

Umax.

void o

f

inte

rface

RS 2

32

The distributed meter version (FL 1035): the free end of the signal cable from the electronic unit is to be connected to the respective spring-loaded WAGO terminals at terminal board X2 in the sensor unit assembly. The lid on the terminal box is held in position by means of four M4 screws with hexagonal socket heads for Alien wrench size 3mm. In the IP 68 design version of the remote sensor, the connection cable to the associated electronic unit (bringing the ultrasonic probe signals to the electronic unit) is fitted on both sides at the manufacturing company. The output signal cable connections to terminal board X1 are made in the same way as shown above for the case of the compact meter version.

Page 16: Ultrasonic flow meter FLOMIC FL 103X - tepso.ee

ELIS PLZEŇ a. s.

Design, Assembly and Service Manual

Page 16 of 28Ultrasonic flow meter FLOMIC FL 103X

ELIS PLZEŇ a. s., Luční 15, P. O. BOX 126, 304 26 Plzeň, Czech Republic, tel.: +420/377 517 711, fax: +420/377 517 722 Es 90 345 K/d

X2

9

-I +I +

RS

-R

S

876

+IM

P-I

MP

42 31

M-B

US

/TX

M-B

US

/RX

5X1

remov

ed

X2 4 3 2 1

P

X2 4 3 2 1

VIEW P

CONNECTIONS BETWEEN ELECTRONIC UNIT AND FLOW SENSOR

PRO BE 2 PRO BE 1

FLOW SENSOR TERMINAL BOARD

of the electronic unit with the top cover removed

brown white

Cu

rre

nt o

utp

ut

Imp

ulse

ou

tpu

t

inte

rfac

e R

S 2

32C

om

mu

nica

tion

(ext

ern

al p

ower

sup

ply

)

(ext

ern

al p

ower

sup

ply

)

Co

mm

uni

catio

n

inte

rfac

e M

-BU

S

warran

ty

void

if

warranty

void if

remov

ed

FL 1

035

GN

7 610 9 8X2

YE

4 1235

BN

X2 7

FL 1

035

GAUGE

6 2 1

2 PRO BE 1

345910 8

PRESSURE

YE GN BN WH

METER VERSIONINCLUDINGPRESSURE GAUGE

WH

X4

ELECTRONIC UNIT

FLOW SENSOR TERMINAL BOARD

remov

ed

void if

warranty

remov

ed

void if

warranty

ELECTRONIC UNIT

WHBN

5.2.4. Seals on meters The flow meters used as technological meters shall be provided with clamp-on and stick-on company and assembly

seals as shown in the following illustration pictures.

Page 17: Ultrasonic flow meter FLOMIC FL 103X - tepso.ee

ELIS PLZEŇ a. s.

Design, Assembly and Service Manual

Page 17 of 28Ultrasonic flow meter FLOMIC FL 103X

ELIS PLZEŇ a. s., Luční 15, P. O. BOX 126, 304 26 Plzeň, Czech Republic, tel.: +420/377 517 711, fax: +420/377 517 722 Es 90 345 K/d

The compact meter version, type FL 1034

9

-I +I

+RS

-RS

876

+IM

P-I

MP

42 31

M-B

US/

TXM

-BU

S/RX

5

X1

Stick-on company seals

on terminal board cover

VIEW P

Stick-on assembly seal

VIEW R( with top cover removed)

MPa

mA

ba r

l/imp

Ser. No.DN

PRESSURE

PRESSURE RANGE

CURRENT O UTPUT

IM PUL SE O UTPUT CO NST.

warrantyvoid ifremoved

void

ifwar

ranty

rem

oved

warrant

y

void if

remove

dX2

9 03

P

R

Page 18: Ultrasonic flow meter FLOMIC FL 103X - tepso.ee

ELIS PLZEŇ a. s.

Design, Assembly and Service Manual

Page 18 of 28Ultrasonic flow meter FLOMIC FL 103X

ELIS PLZEŇ a. s., Luční 15, P. O. BOX 126, 304 26 Plzeň, Czech Republic, tel.: +420/377 517 711, fax: +420/377 517 722 Es 90 345 K/d

The distributed meter version, type FL 1035

6. OPERATIONAL START

The flow meter is delivered calibrated and in a fully operative condition. Once it is fitted into the selected metering point in the piping, bled and filled with the technological fluid, it is ready for operation. The condition of readiness to start is indicated by disappearance of the error message signs at the bottom of the meter display unit. Using the control push-button, check the selection of measurement modes: the instantaneous flow rate, total volume passed and pressure (if applicable).

R

VIEW R

on term inal board cover

Clasp-on assembly seals

( with top cover removed)DATA-PROCESSING ELECTRONIC UNIT

FLOW SENSOR

on connecting cable housing

Stick-on company seals

Stick-on assembly seal

MPa

mA

bar

l/imp

Ser. No.DN

PRESSURE

PRESSURE RANGE

CURRENT OUTPUTIMPULSE OUTPUT CONST.

warran

ty

void

if

remov

ed

warranty

void if

remov

ed

warrantyvoid ifremoved

9

-I +I

+R

S -

RS

876

+IM

P-I

MP

42 31

M-B

US

/TX

M-B

US

/RX

5

X1

X2

Page 19: Ultrasonic flow meter FLOMIC FL 103X - tepso.ee

ELIS PLZEŇ a. s.

Design, Assembly and Service Manual

Page 19 of 28Ultrasonic flow meter FLOMIC FL 103X

ELIS PLZEŇ a. s., Luční 15, P. O. BOX 126, 304 26 Plzeň, Czech Republic, tel.: +420/377 517 711, fax: +420/377 517 722 Es 90 345 K/d

7. OPERATION

7.1. Reading the measured quantities from the meter display The eight-character display unit can show either the instantaneous flow rate in m3/hour (or G/min), the total

volume of the fluid passed through the meter sensor since the reading was last reset, in m3 (or in G), or the fluid pressure (provided the meter assembly includes a pressure gauge). Some of the displayed values need be multiplied by a coefficient from the following table. The reading of instantaneous flow rate has a certain delay as the displayed value is determined as the arithmetic average of the six latest measurements (each taken in 1-second intervals). So calculated values also appear at the meter outputs. The delay becomes noticeable in the cases of rapidly changing (growing or falling) flow rate. Meter errors will be indicated on the display. Due to the limited power capacity of the meter, the various display modes can only be selected in intervals of 1 second or longer. It is therefore recommended that the display mode selection push-button be always depressed for at least one second, and the next selection command be given after another 1 second or longer. Depending on the total volume of fluid passed through the meter sensor and the associated coefficient, the decimal point on the display will move as shown in the following picture.

IMPORTANT NOTICE: The displayed values and values recorded in archive need be multiplied by a coefficient given in the table below. The same coefficient is shown on the front panel under the metering units (m3 and m3/hour, or G and GPM) - see section 3.2.4.

7.2. Electrical outputs

7.2.1. Impulse output The passive impulse output is found on any FLOMIC FL flow meters irrespective of their version or configuration. In

includes an optocoupler connected to terminals 7 and 8 (terminal board X1); the impulse length is 50 ms and permitted current loading 10 mA .This arrangement presumes that the loading resistance of the customer׳s equipment is between 1 and 47 kΩ and the external voltage source within the range of 5 to 25V. Should the customer׳s equipment not meet

Rated inner diameter DN 32 40 50 65 80 100 125 150 200 250 300

Coefficient

m3/hour - - - - - - x 10 x 10 x 10 x 10 x 10

m3

G/min - - - - - - x 10 x 10 x 10 x 10 x 10

G x 103 x 103 x 103 x 103 x 103 x 103 x 104 x 104 x 104 x 104 x 104

8-digit valuesDecimal point for

Display of pressure inbars - decimal point

Decimal point for 7-digit values

values up toDecimal point for

5 digits

6-digit valuesDecimal point for

Page 20: Ultrasonic flow meter FLOMIC FL 103X - tepso.ee

ELIS PLZEŇ a. s.

Design, Assembly and Service Manual

Page 20 of 28Ultrasonic flow meter FLOMIC FL 103X

ELIS PLZEŇ a. s., Luční 15, P. O. BOX 126, 304 26 Plzeň, Czech Republic, tel.: +420/377 517 711, fax: +420/377 517 722 Es 90 345 K/d

these requirements, it is possible to use external power source consisting of Li 6V-battery connected in series with resistance 22 kΩ, or to select the impulse length of 2 ms The impulse length can also be modified on site; for 50ms impulses, use jumper J5 to connect terminals J5:2 and J5:3 (X1), for 2ms impulses, connect terminals J5:1 and J5:2 (see the figure below).

7.2.2. Current output The passive current output 4 ÷ 20mA is connected to terminals 5 and 6 at the output terminal board (X1). Upon

attaining the output current level of 20mA (corresponding to Qmax), the current will not exceed this value and the error message E4 will appear on the display (see Section 7.5. below). To utilize the output current function, use an external power source of 10 to 24VDC and the interconnection at the output terminal board as described in Section 5.2.3. The maximum permitted resistance (the ohmic resistance of the cable + input resistance of the co-operating equipment) of the current output circuit shall be determined using the following formula:

Rs [Ω] = U source [V] - 7 0.02

7.3. Communication interface

7.3.1. Communication via optical interface

Via the optical interface the meter operator can read the real-time measured data (instantaneous flow rate, total volume passed and pressure of the fluid), the stored data of earlier operational periods, the parameters of the data archiving function and the error messages generated. The meter software programs allow for storage, at regular user-defined intervals, of the measured values of instantaneous flow rate, total fluid volume passed, fluid pressure, maximum and minimum values of instantaneous flow rates over the recent measurement period plus information on the times when such extreme values occurred. Apart from these data, stored can also be any error messages plus the times when these were generated. To be able to utilize the optical communication function, the user shall have the ArchTerm data-processing program installed in their notebook or personal computer, and have available an optical probe with a 1.5m cable including a connector to RS 232.Upon the customer׳s request, the meter configuration may include an optical probe with a connector to USB.

The optical probe shall be applied to a recess on the electronic unit box with the correct position defined by an arresting pin; the probe is held in operating position by a permanent magnet.

7.3.2. Communication via RS 232 The communication via an RS 232 line uses the signals connected to terminals 1 to 4 (X1) by the permanently

attached signal cable. The data reading and archiving, reading of error messages and checking the parameters of the data archiving function can be done to the same extent as described in Section 7.3.1 above. The co-operating PC shall have the ArchTerm communication program installed. It is also possible to connect a GSM module. In this case, the electronic unit was configured at the manufacturer׳s plant and no subsequent on-site modifications can make it communicate via the M-Bus interface.

X1

1 2 3

1 2 3 4 5 6 7 8 9

J5

Page 21: Ultrasonic flow meter FLOMIC FL 103X - tepso.ee

ELIS PLZEŇ a. s.

Design, Assembly and Service Manual

Page 21 of 28Ultrasonic flow meter FLOMIC FL 103X

ELIS PLZEŇ a. s., Luční 15, P. O. BOX 126, 304 26 Plzeň, Czech Republic, tel.: +420/377 517 711, fax: +420/377 517 722 Es 90 345 K/d

7.3.3. Communication via M-Bus The communication system with an M-Bus interface uses the signals available on terminals 3 and 4 (X1) and allows

for reading of the values of instantaneous flow rate and total volume passed. In this case, the meter is configured for the M-Bus communication and no subsequent modifications are possible to change this to the RS 232 system communication.

7.4. Communication modes

7.4.1. Optical probe + PC (or notebook computer) The free end of the optical probe cable is normally provided with an RS 232 connector. Converter RS 232/USB is

included in the scope of supply. Optional accessory is optical probe and USB connector. To activate the USB connection, a special controller needs be installed on the PC (supplied with the probe).

7.4.2. RS 232 + PC (or notebook computer) The free end of the cable from the connection box shall be interconnected to terminals 1 through to 4 (X1) in the

meter electronic unit (see the circuit diagram below). The cable is supplied 5m long and can be shortened as need be; on the side of the connection box the cable is fixed in a sealing compound. The cable between the connection box and PC is provided with the necessary connectors (an RS 232 connector on the PC side).

1,5m

OPTICAL HEAD

removed

warranty

IMPULSE OUTPUT CONST. CURRENT OUTPUT

PRESSURE RANGE

PRESSURE

DN Ser. No.

l/imp

barmA

MPa

void if

YE

BN

WH

GN

CONNECTION BOX

ELECTRONIC

(white)(green)

(brown)(yellow)

UNIT

CONNECTION BOX

removed

warranty

IMPULSE OUTPUT CONST. CURRENT OUTPUT

PRESSURE RANGE

PRESSURE

DN Ser. No.

l/imp

barmA

MPa

void if

RS 2

32

max

. 5m

1 2 3 4 5 6 7 8 9X1

Page 22: Ultrasonic flow meter FLOMIC FL 103X - tepso.ee

ELIS PLZEŇ a. s.

Design, Assembly and Service Manual

Page 22 of 28Ultrasonic flow meter FLOMIC FL 103X

ELIS PLZEŇ a. s., Luční 15, P. O. BOX 126, 304 26 Plzeň, Czech Republic, tel.: +420/377 517 711, fax: +420/377 517 722 Es 90 345 K/d

7.4.3. RS 232 + GSM module

One end of the 5m-long connecting cable (it can be shortened if convenient) is provided with a connector to the GSM module. At the other end, the cable shall be connected to terminals 1 through to 4 (X1) in the meter electronic unit (see the following picture).

7.5. Distributed meter version

With the distributed meter version (separate sensor and electronic unit), any of the communication modes described above in Sections 7.4.1., 7.4.2. or 7.4.3. is possible.

OF SENSOR

REMOTE VERSIONOF ELECTRONIC

THE SAME VARIANTS OF COMMUNICATION AS FOR COMPACT VERSION

UNIT

REMOTE VERSION

removed

warranty

IMP U L S E O U T P U T C O N S T . C U R R E N T O U T P U TP R E S S U R E R A N G E

PRESSURE

DN Ser. No.

l/imp

b a rm A

MPa

voi d i f

max.

5m

PC / CONTROL SYSTEM

UNIT

(yellow)(brown)

(green)(white)

CONNECTORGSM UNIT

ELECTRONIC

removed

w arran ty

IM P U L S E O U T P U T C O N S T . C U R R E N T O U T P U T

P R E S S U R E R A N G E

PRESSURE

DN Ser. No.

l/imp

b a rm A

MPa

voi d i f

GSM NETWORKRS 232

GSM MODULE

INTERNET

SERVER

max. 5m

GN

WH

BN

YE

X1 987654321

Page 23: Ultrasonic flow meter FLOMIC FL 103X - tepso.ee

ELIS PLZEŇ a. s.

Design, Assembly and Service Manual

Page 23 of 28Ultrasonic flow meter FLOMIC FL 103X

ELIS PLZEŇ a. s., Luční 15, P. O. BOX 126, 304 26 Plzeň, Czech Republic, tel.: +420/377 517 711, fax: +420/377 517 722 Es 90 345 K/d

7.6. Error identification function Meter errors will be identified as E1 through to E5 by symbol shown at the bottom of the display unit. Error identification symbols: E1 - the ultrasonic signal cannot freely propagate in the sensor cavity (due to the presence of air or mechanical particles) E2 - too great a difference between the signal travel times in and against the fluid

flow direction (possibly due to the presence of air at one of the probes, which may be a temporary condition during the operation of filling the piping with

fluid, or due to contamination of the face part of one of the probes) E3 - A/D converter error (e.g. due to strong electromagnetic interference) E4 - flow rate in excess of qs E5 - flat meter battery Should the display go completely blank, check the battery condition (the voltage should be over 3V). Replace defective battery using the procedure described in Section 7.6. Should the battery replacement fail to restore the correct meter function, send the meter for repair to the manufacturer’s service centre.

7.7. Battery life and replacement The battery lifetime in a meter of a standard configuration is 8 years, in a meter including various optional functions

6 years. The battery compartment is sealed with an assembly seal to indicate that battery replacement is reserved to staff who are authorised to remove and place/replace assembly seals on the meter components. While the battery is being replaced, all stored data including those on the total volume of fluid passed through the metering point are protected. The recommended battery brand is SAFT LITHIUM 3.6V/16Ah, type designation LS 33600.

On customer’s request, electronic unit can be equipped with the smaller SAFT LITHIUM 3.6V /3.6Ah LSH 14 "light" battery containing less than 1g of lithium and provided with a plastic case ensuring correct fit in the battery holder. The lifetime of an LSH 14 "light" battery is 1 year since the production date and it can be at any time replaced by the standard 16Ah battery.

To replace the meter battery, first remove the plastic lid on the electronic unit box held in position by two M4 screws with hexagonal socket heads (use Alien wrench, size 2mm), then loosen three M3 bolts holding the electronic module in the aluminium box and pull the module outside the box. While doing that, make sure you do not damage any metrological or company seals. The electronic module can be pulled out as far as the probe conductors and output signal cables permit. The battery is located in a holder at the bottom of the unit; pull the old battery out and replace it with a new one. Mind the correct polarity as indicated on a plate on the battery holder. Push the electronic module back into the box, tighten the holding bolts, replace the box lid, fix its position with screws and apply assembly seal on one of them.+

The electronic module removed from its box

MOUNTING SCREWS M3ELECTRONIC UNIT ASSEMBLY

PLATE SHOWINGBATTERY POLARITY

BATTERY

BATTERY HOLDER

STICK-ON SEALS

rem ovedDIRECTION OF PULLINGBATTERY FROM HOLDER

void ifw arranty

w arra

nty

void

if

rem

oved

Page 24: Ultrasonic flow meter FLOMIC FL 103X - tepso.ee

ELIS PLZEŇ a. s.

Design, Assembly and Service Manual

Page 24 of 28Ultrasonic flow meter FLOMIC FL 103X

ELIS PLZEŇ a. s., Luční 15, P. O. BOX 126, 304 26 Plzeň, Czech Republic, tel.: +420/377 517 711, fax: +420/377 517 722 Es 90 345 K/d

8. CALIBRATION The FLOMIC ultrasonic flow meters are supplied calibrated according to standard ČSN EN 14 154-3. The

calibration method used is known as “running start on scales – automatic impulses” where the beginning and end of the calibration test are given by output impulses from the flow meter. On customer’s request, more precise calibration can be performed.

The flow meter calibration can be performed by duly authorised and properly equipped service centres provided they have executed the necessary agreements with the meter manufacturer. In checking the meter functions, precision and in performing the calibration procedures, the measurement and test methods specified by standard ČSN EN 14 154-3 and the manufacturer’s specification Es 90 061 Z shall be used.

9. WARRANTY AND POST-WARRANTY SERVICES

9.1. Warranty services Warranty services are understood to include repairs, performed free of charge, of any defects in products occurring

within the agreed warranty period, where such repair work can either be executed at the manufacturer’s plant or at the authorized service centres.

Warranty services are understood to include repairs, performed free of charge, of any defects in products occurring within the agreed warranty period to the extent and provided that such defects can be attributed to non-compliant materials, product parts or non-standard manufacturing procedures.

Should any such defect prove irreparable, the respective product will be replaced free of charge. Warranty repairs can only be performed by the product manufacturer (ELIS PLZEŇ a.s.) or their duly authorized

service centre or product distributor (based on authorisation in writing by the manufacturer and following the necessary training). Exempt from the warranty services shall be: - products on which the company or metrological seals have been broken;

- products defective due to incorrect assembly or fitting; - product defects due to non-standard use; - product defects due to wrong battery polarity; - products alienated or disposed of; - product defects due to force majeure or elementary disaster; - product defects due to mechanical damage.

A requirement for warranty repair shall be placed with the manufacturer in writing (by e-mail, fax or registered post). Should the manufacturer not acknowledge the customer’s claim on warranty repair, a notice in writing to this effect willl be sent to the customer and the product repair costs will be invoiced to the same. In the case of invoicing (commercial) meters, the repaired equipment shall be verified by the duly authorised metrological centre.

9.2. Post-warranty services

The post-warranty services are understood to include any and all repairs of product defects originating after the agreed warranty period. Such repairs, irrespective of whether they are performed at the manufacturer’s plant or elsewhere according to the customer’s instructions, will be invoiced to the customer.

In the case of invoicing (commercial) meters, the repaired equipment shall be verified by the duly authorised

metrological centre. A requirement for post-warranty repair shall be placed with the manufacturer in writing (by e-mail, fax or registered

post).

Page 25: Ultrasonic flow meter FLOMIC FL 103X - tepso.ee

ELIS PLZEŇ a. s.

Design, Assembly and Service Manual

Page 25 of 28Ultrasonic flow meter FLOMIC FL 103X

ELIS PLZEŇ a. s., Luční 15, P. O. BOX 126, 304 26 Plzeň, Czech Republic, tel.: +420/377 517 711, fax: +420/377 517 722 Es 90 345 K/d

10. PRODUCT ORDERING To order a FLOMIC flow meter, use an order code number identified by means of the following table. The table

is also available at the Internet address www.elis.cz.

Position ordinal No. of the ordering No. 1 2 3 4 5 6 - 7 8 9 10 11 12 13 14 15 16 17

ORDERING No.: F L 1 0 3

TYPE IDENTIFICATION

Design version compact 4 remote 5

TECHNICAL PARAMETERS

Sensor size DN/ 32/25/10 0 1 nominal flow Q3 [m3/h]/ 40/40/25 0 2 pulse output constant 50/63/25 0 3 ki [l/imp] 65/100/50 0 4 80/160/100 0 5 100/250/100 0 6 125/400/250 0 7 150/630/250 0 8 200/1000/500 0 9 250/1600/500 1 0 300/2500/1000 1 1

Nominal pressure PN 16 1 40 2 non-standard 0

Used flanges of the sensor EN 1092-1 1 ANSI B 16.5 2 JIS B 2210 3 AS 2129 4 non-standard 0

Type of sensor combination of carbon and stainless steel, painted 1 stainless steel for drinking water 2 non-standard 0

Protection of sensor standard IP 67 1 option IP 68 - for remote version 2

Current output yes 1 no 2

Data communication no data communication 1 data archive 2 data archive + optical head 3 data archive + RS 232 4 data archive + GSM 5

Pressure measuring 1 -16 bar yes 1 no 2

Remote version 0 - compact version 1 cable length [m] 2 2 3 3 4 4 5 5 non-standard 0

CALIBRATION

Calibration not calibrated 1 standard calibration in 3 points, with calibration protocol 2 non-standard calibration in 5 points, with calibration protocol 3 non-standard calibration in 7 points, with calibration protocol 4

Page 26: Ultrasonic flow meter FLOMIC FL 103X - tepso.ee

ELIS PLZEŇ a. s.

Design, Assembly and Service Manual

Page 26 of 28Ultrasonic flow meter FLOMIC FL 103X

ELIS PLZEŇ a. s., Luční 15, P. O. BOX 126, 304 26 Plzeň, Czech Republic, tel.: +420/377 517 711, fax: +420/377 517 722 Es 90 345 K/d

Position ordinal No. of the ordering No - 18 19 20 21 22 23 24 25 ORDERING No.

PURCHASING CONDITIONS

Quantity 1 piece 0 0 1 2 pieces 0 0 2 3 pieces 0 0 3

. . .

. . .

.

.

.

.

.

.

999 pieces 9 9 9 1000 pieces and more 0 0 0

User manual language Czech 1 English 2

Packing unpacked 1 standard 2 export 3 non-standard 0

Handover method personally 1 by shipping agent on supplier costs 2 by shipping agent on buyer costs 3 non-standard 0

Warranty 6 months 1 12 months 2 18 months 3 24 months 4 36 months 5 non-standard 0

Manual code designation Es 90 345K 1 to be included as position 25 into the Order Number

Page 27: Ultrasonic flow meter FLOMIC FL 103X - tepso.ee

ELIS PLZEŇ a. s.

Design, Assembly and Service Manual

Page 27 of 28Ultrasonic flow meter FLOMIC FL 103X

ELIS PLZEŇ a. s., Luční 15, P. O. BOX 126, 304 26 Plzeň, Czech Republic, tel.: +420/377 517 711, fax: +420/377 517 722 Es 90 345 K/d

Page 28: Ultrasonic flow meter FLOMIC FL 103X - tepso.ee

ELIS PLZEŇ a. s.

Design, Assembly and Service Manual

Page 28 of 28Ultrasonic flow meter FLOMIC FL 103X

ELIS PLZEŇ a. s., Luční 15, P. O. BOX 126, 304 26 Plzeň, Czech Republic, tel.: +420/377 517 711, fax: +420/377 517 722 Es 90 345 K/d

Manufacturer’s address:

ELIS PLZEŇ a. s. Luční 15, P. O. BOX 126

304 26 Plzeň Czech Republic

Tel.: +420 377 517 711 Fax: +420 377 517 722 E-mail: [email protected]

http://www.elis.cz

Issue No. 5