ultrasonic flowmeter

Upload: anand-bagade

Post on 19-Oct-2015

18 views

Category:

Documents


0 download

DESCRIPTION

Electronet-ASICOT ultrasonic ASIONIC-100 Ultrasonic Flowmeter

TRANSCRIPT

  • ASIONIC-100

    ULTRASONIC FLOWMETER

    DESCRIPTION

    SALIENT FEATURES

    INLINE ULTRASONIC FLOWMETER

    ELECTRONETASIONIC 100

    - Suitable for conductive / non conductive liquid.

    - No moving parts hence no pressure loss

    - Full bore type

    - Local indication with COG graphics display

    - Simple and cost effective solution

    - High accuracy

    - Communication Rs485 / HART (Optional)

    - Long term stability over wide range of measured value

    ASIONIC-100 ultrasonic ow meters are intended for measurement and storage of the measured data of instantaneous ow rate

    and total volume passed through the meter sensor, of cold and hot water and other liquids of similar properties in water and heat

    supply systems and in a wide range of industrial applications. The ASIONIC meters are noted for high measurement accuracy and

    long-term stability over a wide range of measured values. No external power is needed; the meters include no movable parts and,

    compared to conventional ow meters, their hydraulic losses are signicantly lower. The associated electronic unit provides for

    processing of the sensor signals and visualization of the values of instantaneous ow rate, total uid volume passed through the

    meter sensor and uid pressure, as well as for archiving of the measured data in specied time intervals in the internal meter

    memory unit. The archived data can be retrieved RS-485 communication. On-line processing of the measured values is also

    possible using the current (4 to 20 mA) outputs or via the M-Bus communication interface.

    TECHNICAL SPECIFICATIONS

    Page 1 of 1CAT/ASIONIC 100

    METERSPECIFICATIONS

    material : Carbon or stainless steel

    RS-485 or M-Bus communication interface

    Measured units m3/hr pr lit/min (showing ow rate and ow totaliser)

    Remote meter ver

    On-line processing of the measured values is also possible using the

    current (4 to 20 mA) outputs

  • Line SizeSERIES Flange

    25 mm to

    600 mm 01 CS / MS

    02 SS

    Communi-

    cation

    02 485

    01A 02C 65 mmASIONIC - 100

    REGISTERED

    FIRM

    ISO 9001-2008

    Plot No 84,85 & 86, Tiny Industrial Estate, Kondhwa Budruk, Pune - 411 048 Maharashtra, INDIATelefax : +91 20 2693 4122 / 1476, Sales : +91 20 2693 4121E-mail : [email protected] Web : www.eeplindia.com

    ELECTRONET EQUIPMENTS PVT. LTD.PROCESS CONTROL INSTRUMENTS & AUTOMATION

    RE BWEO

    P FO

    E

    R

    T

    EAL

    O

    O

    P

    S

    EI

    N

    :

    IN

    N

    G

    OI

    C

    T

    OU

    VA EC R:

    ASIONIC - 100

    MENU

    ULTRASONIC FLOWMETER

    L

    FD

    H

    250

    mm

    DIMENSIONAL DETAILS

    W

    FL

    OW

    NO

    MO

    GR

    AP

    H

    Flow-meter should be selected with the help of Nomograph.

    Recommended Full Scale Velocity

    2 to 3 m/s for homogeneous media

    3 to 5 m/s for non viscous media with solid contents

    All dimensions are indicative dimensions.

    25 NB 150 100 180 200

    32 NB 180 100 210 200

    40 NB 180 100 210 200

    50 NB 180 100 210 200

    65 NB 185 100 220 200

    80 NB 207 100 240 200

    100 NB 250 150 274 250

    125 NB 280 175 300 250

    150 NB 320 175 330 300

    200 NB 380 175 390 350

    250 NB 420 244 440 450

    300 NB 520 250 520 500

    350 NB 520 250 520 550

    400 NB 520 250 520 600

    450 NB 627 623 632 698

    500 NB 679 623 686 768

    600 NB 770 818 772 918

    Meter L W H FD

    Size (mm) (mm) (mm) (mm)

    63.62 17.67

    113.09 31.42

    1.77 0.49

    176.7 49.09

    2.90 0.80

    254.46 70.68

    4.52 1.26

    346.35 96.21

    7.07 1.96

    452.38 125.66

    11.95 3.32

    572.54 159.04

    18.10 5.03

    706.84 196.34

    28.27 7.85

    1017.84 282.74

    44.18 12.27

    Flow Range (Velocity=1m/s)3

    (m/hr) (LPS)

    INSTALLATION DRAWING

    ORDERING INFORMATION

    REW BO EP F

    OE

    R

    T

    EAL

    O

    O

    P

    S

    EI

    N

    :

    IN

    N

    G

    OI

    C

    T

    O

    UVA EC R:

    MENU

    Outlet Flow

    10D Straight Length (min) 10D Straight Length (min)

    Pipe Support

    Pipe Support Pipe Support

    Pipe Support

    Valve

    Valve

    Inlet Flow

    D = Line Size

    01 4-20mA

    ASIONIC - 100

    ULTRASONIC FLOWMETER

    Line size upto 2000NB is available, details will be transferred

    on special request

    Power

    01 230VAC

    02 24VDC

    01B

    supplyTransmitter

    02 Remote

    02D

    01 Inbuilt

    Page 1Page 2