underwoods
DESCRIPTION
Automation InnovationTRANSCRIPT
![Page 1: Underwoods](https://reader033.vdocument.in/reader033/viewer/2022042901/568c35ec1a28ab023596148e/html5/thumbnails/1.jpg)
www.ued.co.uk
Automation Innovations
![Page 2: Underwoods](https://reader033.vdocument.in/reader033/viewer/2022042901/568c35ec1a28ab023596148e/html5/thumbnails/2.jpg)
Demonstration KitA range of demonstration equipment based on micro-automation solutions showing examples of HMI-PLC Communications, positioning, integrated drives and closed loop control.
The demonstration equipment is configured to show many of the typical applications found in Industry.
Technical SupportNew and complex control equipment requires a high quality technical package. Underwood’s offer this service to our customers specialising in the technical support of Siemens automation and drives products with emphasis on the new S7-1200 plc and S110 drive micro automation solutions.
The type of service we offer is driven by our customer specific requirements, these include product selection, software assistance, sample programs and site visits.
We believe that these support services permit customers to get the maximum benefit from their investment in new control equipment whilst minimising the risks associated with installation, commissioning and long term use.
Training RoomsWe have well equipped training rooms allowing us to hold seminars, training courses, product and software updates. The training and refresher courses are designed to get the engineer up to speed with the latest engineering software.
Introductory courses are designed to familiarise customers at all levels with the latest developments in hardware, software and the benefits to be derived from them. These courses are run regionally around the UK.
Maintenance courses are designed for staff that require the ability to systematically and quickly fault find and rectify the problem or make simple modifications to problems.
Specialist courses are tailored around specific requirements e.g communications, networks and human machine interface
Underwoods working in
partnership with Siemens
Technical Support
Training Rooms
Demonstration Kit
Underwoods succeeds by providing the total automation and control hardware solutions you need to enable your enterprise to succeed. Working in partnership with the industry’s foremost manufacturer, we select products that are both technically and economically viable and supply them to you - to specification, to budget and on time.
2 www.ued.co.uk
![Page 3: Underwoods](https://reader033.vdocument.in/reader033/viewer/2022042901/568c35ec1a28ab023596148e/html5/thumbnails/3.jpg)
OVERVIEW - SIMATIC S7-1200 & SINAMICS S110
SIMATIC S7-1200
- the modular micro controller
SIMATIC S7-1200 is characterised by its versatile and flexible design concept while offering high performance and extremely compact dimensions.
Main characteristics of the micro controllers: • New design concept: A host of modules and new signal boards
considerably increase the degree of scalability and flexibility.
• Powerful communication: The integrated PROFINET interface ensures low-cost communication during programming, HMI connections and CPU-CPU communication. An ethernet switch is available for networking several devices with one another.
Expansion by means of communication modules also allows serial communication.
• Integrated technology functions: High-performance functions forcounting, measuring, closed-loop control and for motion control open up new areas of application for the micro controller.
This offers the user immediate advantages: • Quicker start up • Total integration • Common database • Click and drag
These are some of the benefits which TIA Portal give you.
• Simple networking between controllers, HMI panels and engineering components.
• Smart options for demanding solutions in the technology sector.
SINAMICS S110
SINAMICS S110 - The basic positioning drive for single-axis applications.
Many applications in mechanical engineering and plant construction require machine axes to be positioned quickly and precisely by the simplest possible method. It is often simply a case of moving a machine axis from position X to position Y reliably and with the required level performance. The SINAMICS S110 drive convertor is ideally suited to this type of application. It is specifically designed to position single axes accurately and effectively.
SINAMICS S110 is the perfect solution for many applications.
Typical examples are: • Handling equipment • Feed and withdrawal devices • Stacking units • Automatic assembly machines • Laboratory automation • Metal working • Machine used in the wood, glass and ceramics industries • Printing Machines • Plastic processing machines
The so-called basic positioner (EPos) is an integral component of the SINAMICS S110. It provides a simple method of solving positioning tasks. The SINAMICS S110 is designed for connection to both synchronous servo motors and asynchronous (induction) motors. It supports all of the most popular types of encoder.
A variety of field bus interfaces is provided for linking the unit to a higher-level control system. Alternatively, it can be controlled via a ± 10 V setpoint interface.
An outstanding feature of the SINAMICS S110 convertor is its integrated safety functions (Safety Integrated) which make it easy to provide highly effective protection for personnel and machinery.
3www.ued.co.uk
![Page 4: Underwoods](https://reader033.vdocument.in/reader033/viewer/2022042901/568c35ec1a28ab023596148e/html5/thumbnails/4.jpg)
SIMATIC S7-1200
CPU’S PART NUMBER
CPU 1211C DC/DC/DC 6DI / 4DQ + 2AI 6ES7 211-1AD30-0XB0
CPU 1211C AC/DC/Rly 6DI / 4DQ + 2AI 6ES7 211-1BD30-0XB0
CPU 1211C DC/DC/Rly 6DI / 4DQ + 2AI 6ES7 211-1HD30-0XB0
CPU 1212C DC/DC/DC 8DI / 6DQ + 2AI 6ES7 212-1AD30-0XB0
CPU 1212C AC/DC/Rly 8DI / 6DQ + 2AI 6ES7 212-1BD30-0XB0
CPU 1212C DC/DC/Rly 8DI / 6DQ + 2AI 6ES7 212-1HD30-0XB0
CPU 1214C DC/DC/DC 14DI / 10DQ + 2AI 6ES7 214-1AE30-0XB0
CPU 1214C AC/DC/Rly 14DI / 10DQ + 2AI 6ES7 214-1BE30-0XB0
CPU 1214C DC/DC/Rly 14DI / 10DQ + 2AI 6ES7 214-1HE30-0XB0
OTHER ITEMS PART NUMBER
SIMATIC S7-200 PSU 24V DC 2.5A 6EP1 332-1SH71
Local 2 mtr Expansion Cable 6ES7 290-6AA30-0XA0
SIMATIC Memory Card 2 MB 6ES7 954 -8LB00-0AA0
SIMATIC Memory Card 24 MB 6ES7 954 -8LF00-0AA0
SIMATIC Switch module 6GK7 277-1AA00-0AA0
Expansion I/O (Signal Modules and Signal Boards)
SM INPUT MODULES PART NUMBER 5V DC CURRENT
SM 1221, 8 x 24VDC 6ES7 221-1BF30-0XB0 105mA
SM 1221, 16 x 24VDC 6ES7 221-1BH30-0XB0 130mA
SM OUTPUT MODULES PART NUMBER 5V DC CURRENT
SM 1222, 8 x 24VDC 6ES7 222-1BF30-0XB0 120mA
SM 1222, 16 x 24VDC 6ES7 222-1BH30-0XB0 140mA
SM 1222, 8 x Relay 6ES7 222-1HF30-0XB0 120mA
SM 1222, 16 x Relay 6ES7 222-1HH30-0XB0 135mA
SM COMBINED INPUT/OUTPUT MODULES PART NUMBER 5V DC CURRENT
SM 1223, 8DI x 24VDC/8DQ x 24VDC 6ES7 223-1BH30-0XB0 145mA
SM 1223, 16DI x 24VDC /16DQ x 24VDC 6ES7 223-1BL30-0XB0 185mA
SM 1223, 8DI x 24VDC/8 x Relay 6ES7 223-1PH30-0XB0 145mA
SM 1223, 16DI x 24VDC/16 x Relay 6ES7 223-1PL30-0XB0 180mA
SM ANALOGUE MODULES PART NUMBER 5V DC CURRENT
SM 1231, 4 Channel RTD 6ES7 231-5PD30-0XB0 80mA
SM 1231, 4 Channel Thermocouple 6ES7 231-5QD30-0XB0 80mA
SM 1231, 4 x Analog In 6ES7 231-4HD30-0XB0 80mA
SM 1231, 8 x Analog In 6ES7 231-4HF30-0XB0 90mA
SM 1232, 2 x Analog Out 6ES7 232-4HB30-0XB0 80mA
SM 1232, 4 x Analog Out 6ES7 232-4HD30-0XB0 80mA
SM 1234, 4 x Analog In /2 x Analog Out 6ES7 234-4HE30-0XB0 80mA
CM (COMMUNICATION MODULES) PART NUMBER 5V DC CURRENT
CM 1241, RS232 6ES7 241-1AH30-0XB0 220mA
CM 1241, RS485 6ES7 241-1CH30-0XB0 220mA
SB (SIGNAL BOARDS) PART NUMBER 5V DC C URRENT
SB 1223, 2 x 24VDC In/ 2 x 24VDC Out 6ES7 223-0BD30-0XB0 50mA
SB 1232, 1 Analog Out 6ES7 232-4HA30-0XB0 50mA
SB 1221, 4In x 24VDC @ 200kHz 6ES7 221-3BD30-0XB0 35mA
SB 1222, 4Out x 24VDC @ 200kHz 6ES7 222-1BD30-0XB0 35mA
SB 1223, 2In & 2Out 24VDC @ 200kHz 6ES7 223-3BD30-0XB0 40mA
SB 1221, 4In x 5VDC @ 200kHz 6ES7 221-3AD30-0XB0 35mA
SB 1222, 4Out x 5VDC @ 200kHz 6ES7 222-1AD30-0XB0 35mA
SB 1223, 2In & 2Out 5VDC @ 200kHz 6ES7 223-3AD30-0XB0 40mA
MAX. 5V 750mAONLY EXPANDABLE
WITH SIGNAL BOARD
MAX. 5V 1000mA
* ADDING ANALOGUE SIGNAL MODULES REDUCES THE MAX DIGITAL I/O
* MAXIMUM LOCAL I/O DIGITAL 82/15 ANALOGUE
* MAXIMUM LOCAL I/O DIGITAL 284/51 ANALOGUE
MAX. 2 MODULES
MAX. 5V 1600mA
MAX. 8 MODULES
* MAXIMUM LOCAL I/O DIGITAL 14/3 ANALOGUE
CPU
121
1CCP
U 1
212C
CPU
121
4C
4 www.ued.co.uk
![Page 5: Underwoods](https://reader033.vdocument.in/reader033/viewer/2022042901/568c35ec1a28ab023596148e/html5/thumbnails/5.jpg)
SIMATIC HMI Basic Line
KTP400 MONO PNKTP600MONO PN
KTP600COLOUR PN
KTP1000COLOUR PN
KTP1500COLOUR PN
HARDWARE
Display
Resolution 320x240 680x480 1024x768
Operating System Touch
SOFTWARE
Tags
Screens 50
Messages 200
Trends Yes
Recipes Yes
3RD Party Drivers Yes
TFT with 256 coloursSTN mono
Touch Screen and Fucntion Keys
512256
Basic Panel Colour PN Starter Pack
DESCRIPTION PART NUMBER
KTP400 Basic Panel Mono PN 4” 6AV6 647-0AA11-3AX0
KTP600 Basic Panel Mono PN 6” 6AV6 647-0AB11-3AX0
KTP600 Basic Panel Colour PN 6” 6AV6 647-0AD11-3AX0
KTP1000 Basic Panel Colour PN 10” 6AV6 647-0AF11-3AX0
KTP1500 Basic Panel Colour PN 15” 6AV6 647-0AG11-3AX0
Basic Panel Colour PN Starter Package contains: • KTP xxxx Basic colour Panel • WinCC flexible Compact • PN cable (10 m)
With KTP600 Colour6AV6 652-7DA01-3AA0 With KTP1000 10”Colour6AV6 652-7FA01-3AA0
Programming Software Etc
DESCRIPTION PART NUMBER
SIMTIC STEP 7 BASIC V10.5 inc WinnCC Basic 6ES7 822-0AA00-0YA0
SIMATIC WinCC Basic V10.5 SUS (1 year) 6ES7 822-0AA00-0YL0
1M Ethernet Cable RJ45 6XV1 850-2GH10
2M Ethernet Cable RJ45 6XV1 850-2GH20
6M Ethernet Cable RJ45 6XV1 850 1GH60
Minimum System RequirementsWindows XP SP3 (Home or Pro) Windows Vista (Home Pre, Business 0r Ultimate SP1Pentium 4 -1.7GHz min, DVD ROM1024 x 768 min Screen Resolution
DESCRIPTION PART NUMBER
SIMATIC S7-1200 Starter Pack (CPU 1212C) 6ES7 212-1BD30-4YB0
SIM 1274, 14 Ch. Simulator Module 6ES7 274-1XH30-0XA0
SIM 1274, 8 Ch. Simulator Module 6ES7 274-1XF30-0XA0
Training and Testing
College Pack• 6 x 1214C CPU • 6 x 1AQ Signal Board6 x Input Simulator • 1 x SoftwareDC/DC/DC 6ES7 214-1AE30-4AB3 • AC/DC/REL 6ES7 214-1BE30-4AB3
S7-1200 Starter Kits • S7-1212 AC/DC/Rel+ KTP400 6AV6 651-7AA01-3AA0 • S7-1212 AC/DC/Rel+ KTP600 colour 6AV6 651-7DA01-3AA0
5www.ued.co.uk
![Page 6: Underwoods](https://reader033.vdocument.in/reader033/viewer/2022042901/568c35ec1a28ab023596148e/html5/thumbnails/6.jpg)
SIMATIC S110 Servo Drive
PM340 Power Module Line Voltage 200 ...240V 1AC AMP, KW (HP)
WITHOUT LINE FILTER
WITH LINE FILTER
LINE REACTORS BRAKING RESISTOR SHIELD CONNECTOR
0.9A, 0.12kW (0.2HP) 6SL3210-1SB11-0UA0 6SL3210-1SB11-0AA0
2.3A, 0.37kW (0.5HP) 6SL3210-1SB12-3UA0 6SL3210-1SB12-3AA0 6SE6400-4BC05-0AA0 6SL3262-1AA00-0BA0
3.9A, 0.75kW (1.0HP) 6SL3210-1SB14-0UA0 6SL3210-1SB14-0AA0
PM340 Power Module Line Voltage 380 ...480V 3ACAMP, KW (HP)
WITHOUT LINE FILTER
WITH LINE FILTER
LINE REACTORS BRAKING RESISTOR SHIELD CONNECTOR
1.3A, 0.37kW (0.5HP) 6SL3210-1SE11-3UA0
1.7A, 0.55kW (0.75HP) 6SL3210-1SE11-7UA0
2.2A, 0.75kW (1.0HP) 6SL3210-1SE12-2UA0
3.1A, 1.1kW (1.5HP) 6SL3210-1SE13-1UA0
4.1A, 1.5kW (2.0HP) 6SL3210-1SE14-1UA0 6SE6400-3CC00-6AD3
5.9A, 2.2kW (3.0HP) 6SL3210-1SE16-0UA0 6SL3210-1SE16-0AA0
7.7A, 3.0kW (5.0HP) 6SL3210-1SE17-7UA0 6SL3210-1SE17-7AA0 6SL3201-0BE12-0AA0 6SL3262-1AB00-0DA00
10.2A, 4.0kW (5.0HP) 6SL3210-1SE21-0UA0 6SL3210-1SE21-0AA0 6SL3203-0CD21-4AA0
18A, 7.5kW (10HP) 6SL3210-1SE21-8UA0 6SL3210-1SE21-8AA0
25A, 11kW (15HP) 6SL3210-1SE22-5UA0 6SL3210-1SE22-5AA0
32A, 15kW (20HP) 6SL3210-1SE23-2UA0 6SL3210-1SE23-2AA0 6SL3203-0CD23-5AA0
38A, 18.5kW (25HP) 6SL3210-1SE23-8UA0 6SL3210-1SE23-8AA0
45A, 22kW (30HP) 6SL3210-1SE24-5UA0 6SL3210-1SE24-5AA0
60A, 30kW (40HP) 6SL3210-1SE26-0UA0 6SL3210-1SE26-0AA0 6SL3203-0CD25-3AA0
75A, 37kW (50HP) 6SL3210-1SE27-5UA0 6SL3210-1SE27-5AA0
90A, 45kW (60HP) 6SL3210-1SE31-0UA0 6SL3210-1SE31-0AA0
110A, 55kW (75HP) 6SL3210-1SE31-1UA0 6SL3210-1SE31-1AA0
145A, 75kW (100HP) 6SL3210-1SE31-5UA0 6SL3210-1SE31-5AA0
178A, 125kW (60HP) 6SL3210-1SE31-8UA0 6SL3210-1SE31-8AA0 6SE6400-3CC11-7FD0
6SE6400-3CC01-0AB3 Frame Size A
6SE6400-3CC00-4AB3
Frame Size A
Frame Size B
Frame Size C
Frame Size D
Frame Size E
Frame Size F
3AC FSA NOT AVAILABLE WITH INTEGRAL LINE
FILTER USE EXTERNAL FILTER
6SE6400-2FA00-6AD0
6SE6400-3CC00-2AD3
6SE6400-3CC00-4AD3 6SE6400-4BD11-0AA0 6SL3262-1AA00-0BA0
6SL3203-0CD21-0AA0
6SL3203-0CD22-2AA0
6SL3203-0CJ24-5AA0
6SL3203-0CJ28-6AA0 6SE6400-4BD22-2EA0
6SE6400-4BD21-2DA0
6SE6400-4BD16-5CA0
6SL3262-1AD00-0DA0
6SL3262-1AD00-0DA0
6SL3262-1AF00-0DA0
6SL3262-1AC00-0DA0
6SE6400-3CC11-2FD06SE6400-4BD24-0FA0
6SL3
252-
0BB0
1-0A
A0 SA
TE B
RAKE
REL
AYN.
B WILL
NEE
D MMC
MEM
ORY C
ARD F
OR EX
TEND
ED SA
FETY
FUNC
TIONS
• SAF
E STO
P 1 &
2 WITH
SBR
• SAF
E OPE
RATIN
G STO
P• S
AFET
Y LIM
IT SPE
ED (S
LS) •
SAFE
SPEE
D MON
ITOR
CU305 Control Unit
6SL3055-0AA00-4BA0 BOP206SL3040-0JA00-0AA0 CU305 DP Control Unit6SL3040-0JA02-0AA0 CU305 CAN Control Unit Coming Soon CU305 PN Control Unit
LINE FILTERS Domestic and commercial premises Line Filters 6SE6400-2FA00-06AD0 are to Category A to EN55011
Integral line filters are to Category C2 to EN61800-3
LINE REACTORS Line Reactors reduces system perturbations caused by harmonics in the case of weak line supplies
6SL3040-0JA00-0AA0 CU305 DP Control Unit6SL3040-0JA02-0AA0 CU305 CAN Control Unit Coming Soon CU305 PN Control Unit
BOP20 6SL3055-0AA00-4BA0
POWER SUPPLY
LINE REACTOR
LINE FILTER
POWER MODULE
6 www.ued.co.uk
![Page 7: Underwoods](https://reader033.vdocument.in/reader033/viewer/2022042901/568c35ec1a28ab023596148e/html5/thumbnails/7.jpg)
Only with PM340with integrated �lter
BRAKINGRESISTOR
R2
DCP/R1
DCN
PM-IF interface to CONTROL UNIT CU305
P24
MICROPROCESSOR
24V DV Supplyfor brake
M3~
PEW2
V2U2
PEW1/
L3V1
/L2
U1/L
1
Line reactor
380V to 480V 2AC
L1 L2 L3 PE
Function Underlying Function Reaction
STO • F-D10 on CU305• PROFI sale
SBC (if activated) - NO NO NO
SBC With STO (directly or following expiry of the delay with SS1)
- - - NO NO
SS1 • F-D10 on CU305 STO following expiry of the parameterized delay, followed by SEC (if activated)
- NO NO NO
SS1 • F-D10-2 on CU305• PROFI sale
Safe acceleration monitoring (SBR) during braking. STO & SBC (if activated) following expiry of the parameterizing delay or speed decay before the min. speed limit
STO NO YES YES
SS2 • F-D10-2 on CU305• PROFI sale
Safe acceleration monitoring during braking. Following expiry of the paarameterizing delay SOS.
STO NO YES YES
SOS • F-D10-2 on CU305• PROFI sale
SS1 YES YES YES
SLS • F-D10-2 on CU305• PROFI sale
SS1, STO or SOS
parameterizingYES YES YES
Always Active Indication only YES YES YES
POWER MODULEFor PM340
BasicFunctions
ExtendedFunctions
External set point input
effective
Encoder required
License requiredActivation
6FX5002-2EQ10-....≤ 100 m
Absolute value encoder with EnDat in 1FK7/1PH7
Absolute value encoder with EnDat 6FX2001-5.E.
6FX5002-2CH00-....≤ 100 m
Incremental encodersin/cos 1 Vpp 6FX2001-3...
6FX5002-2CA31-....≤ 100 m
Incremental encodersin/cos 1 V pp with C/D trackin 1FK7/1PH7
6FX5002-2CG00-....≤ 50 m
6FX8002-2CA80-....≤ 50 m
Incremental encodersin/cos 1 Vpp without C/D trackin 1PH7
Incremental encodersin/cos 1 Vpp in 1FK701
6FX5002-2CA20-....≤ 100 m
6FX5002-2CF02-....≤ 50 m (multi-pole resolver)≤ 130 m (2-pole resolver)
Resolver motor 1FK7/1PH7
Resolver motor 1FK7016FX5002-2CF20-....≤ 50 m (multi-pole resolver)≤ 130 m (2-pole resolver)
Absolute value encoder with EnDat in 1FK701
6FX5002-2EQ20-....≤ 100 m
Motor encoder for motors with DRIVE-CLiQ interface 1FK/1FT/1PH
Absolute value encoder with DRIVE-CLiQ6FX2001-5.D..
Power Module PM340
G_D2
11_E
N_00
241
Motor connection for motors with DRIVE-CLiQ interface
Pre-assembled power cables see power cables for motors(max. cable length see Technical Data of the Power Modules)
Motor connection
Motors
X23
6FX.002-2CR00-....
6FX.002-2CD24-....
6FX5002-2AH11-....
6SX7002-0AN30-....
Incremental encoder TTL RS 422 (5 V) 6FX2001-2...
Sensor Module Cabinet-Mounted SMC10for resolver evaluation
Sensor Module Cabinet-Mounted SMC20for sin/cos-and EnDat-encoder
Incremental encoder TTL RS 422 (24 V) 6FX2001-2...
≤ 100 m at 5 V DC
≤ 100 m at 5 V DC
Incremental encoder HTL im Motor 1PH/1PL6≤ 100 m at 5 V DC
≤ 100 m at 5 V DC
Direct connection motor encoderHTL/TTL
U2V2W2
X100
6FX5002-2DC10-....≤ 100 m
6FX2002-1DC00-....≤ 50 m
Control UnitCU305
Incremental encoder HTL 1XP8001 type on motor 1LA1)
1) Not for 2KG geared motor.
Connector with pin contacts
Open core ends
Connector with socket contacts
mmmmaaa
SIMATIC S110 Servo Drive
6SE6400-2FA00-6AD0 Line Filter
6SE6400-3CC00-2AD3 Line Reactor
6SE6400-3CC00-4AB3 Line Reactor
6SE6400-3CC00-4AD3 Line Reactor
6SE6400-3CC00-6AD3 Line Reactor
6SE6400-3CC01-0AB3 Line Reactor
6SE6400-3CC11-2FD0 Line Reactor
6SE6400-3CC11-7FD0 Line Reactor
6SE6400-4BC05-0AA0 Braking Resistor FSA 1AC
6SE6400-4BD11-0AA0 Braking Resistor FSA 3AC
6SE6400-4BD16-5CA0 Braking Resistor FSC 3AC
6SE6400-4BD21-2DA0 Braking Resistor FSD 3AC
6SE6400-4BD22-2EA0 Braking Resistor FSE 3AC
6SE6400-4BD24-0FA0 Braking Resistor FSF 3AC
6SL3040-0JA00-0AA0 CU305 DP Control Unit
6SL3040-0JA02-0AA0 CU305 CAN Control Unit
6SL3054-4AG00-4AA0 MMC Memory Card
6SL3055-0AA00-4BA0 BOP 20
6SL3055-0AA00-5AA0 SMC10 Sensor Module
6SL3055-0AA00-5BA2 SMC20 Sensor Module
6SL3072-0AA00-0AG0 STARTER Commissioning Software
6SL3074-0AA10-0AA0 Safety Licence (extended functions)
6SL3201-0BE12-0AA0 Braking Resistor FSB 3AC
6SL3203-0CD21-0AA0 Line Reactor
6SL3203-0CD21-4AA0 Line Reactor
6SL3203-0CD22-2AA0 Line Reactor
6SL3203-0CD23-5AA0 Line Reactor
6SL3203-0CD25-3AA0 Line Reactor
6SL3203-0CJ24-5AA0 Line Reactor
6SL3203-0CJ28-6AA0 Line Reactor
6SL3210-1SB11-0AA0 PM340 200 ... 240 C 1AC 0.9A, 0.12kW (0.2HP), FSA
6SL3210-1SB11-0UA0 PM340 200 ... 240 C 1AC 0.9A, 0.12kW (0.2HP), FSA
6SL3210-1SB12-3AA0 PM340 200 ... 240 C 1AC 2.3A, 0.37kW (0.5HP), FSA
6SL3210-1SB12-3UA0 PM340 200 ... 240 C 1AC 2.3A, 0.37kW (0.5HP), FSA
6SL3210-1SB14-0AA0 PM340 200 ... 240 C 1AC 3.9A, 0.75kW (1.0HP), FSA
6SL3210-1SB14-0UA0 PM340 200 ... 240 C 1AC 3.9A, 0.75kW (1.0HP), FSA
6SL3210-1SE11-3UA0 PM340 380 ... 480 C 3AC 1.3A, 0.37kW (0.5HP), FSA
6SL3210-1SE11-7UA0 PM340 380 ... 480 C 3AC 1.7A, 0.55kW (0.75HP), FSA
6SL3210-1SE12-2UA0 PM340 380 ... 480 C 3AC 2.2A, 0.75kW (1.0HP), FSA
6SL3210-1SE13-1UA0 PM340 380 ... 480 C 3AC 3.1A, 1.1kW (1.5HP), FSA
6SL3210-1SE14-1UA0 PM340 380 ... 480 C 3AC 4.1A, 1.5kW (2.0HP), FSA
6SL3210-1SE16-0AA0 PM340 380 ... 480 C 3AC 5.9A, 2.2kW (3.0HP), FSB
6SL3210-1SE16-0UA0 PM340 380 ... 480 C 3AC 5.9A, 2.2kW (3.0HP), FSB
6SL3210-1SE17-7AA0 PM340 380 ... 480 C 3AC 7.7A, 3.0kW (5.0HP), FSB
6SL3210-1SE17-7UA0 PM340 380 ... 480 C 3AC 7.7A, 3.0kW (5.0HP), FSB
6SL3210-1SE21-0AA0 PM340 380 ... 480 C 3AC 10.2A, 4.0kW (5.0HP), FSB
6SL3210-1SE21-0UA0 PM340 380 ... 480 C 3AC 10.2A, 4.0kW (5.0HP), FSB
6SL3210-1SE21-8AA0 PM340 380 ... 480 C 3AC 18A, 7.5kW (10HP), FSC
6SL3210-1SE21-8UA0 PM340 380 ... 480 C 3AC 18A, 7.5kW (10HP), FSC
6SL3210-1SE22-5AA0 PM340 380 ... 480 C 3AC 25A, 11kW (15HP), FSC
6SL3210-1SE22-5UA0 PM340 380 ... 480 C 3AC 25A, 11kW (15HP), FSC
6SL3210-1SE23-2AA0 PM340 380 ... 480 C 3AC 32A, 15kW (20HP), FSC
6SL3210-1SE23-2UA0 PM340 380 ... 480 C 3AC 32A, 15kW (20HP), FSC
6SL3210-1SE23-8AA0 PM340 380 ... 480 C 3AC 38A, 18.5kW (25HP), FSD
6SL3210-1SE23-8UA0 PM340 380 ... 480 C 3AC 38A, 18.5kW (25HP), FSD
6SL3210-1SE24-5AA0 PM340 380 ... 480 C 3AC 45A, 22kW (30HP), FSD
6SL3210-1SE24-5UA0 PM340 380 ... 480 C 3AC 45A, 22kW (30HP), FSD
6SL3210-1SE26-0AA0 PM340 380 ... 480 C 3AC 60A, 30kW (40HP), FSD
6SL3210-1SE26-0UA0 PM340 380 ... 480 C 3AC 60A, 30kW (40HP), FSD
6SL3210-1SE27-5AA0 PM340 380 ... 480 C 3AC 75A, 37kW (50HP), FSE
6SL3210-1SE27-5UA0 PM340 380 ... 480 C 3AC 75A, 37kW (50HP), FSE
6SL3210-1SE31-0AA0 PM340 380 ... 480 C 3AC 90A, 45kW (60HP), FSE
6SL3210-1SE31-0UA0 PM340 380 ... 480 C 3AC 90A, 45kW (60HP), FSE
6SL3210-1SE31-1AA0 PM340 380 ... 480 C 3AC 110A, 55kW (75HP), FSF
6SL3210-1SE31-1UA0 PM340 380 ... 480 C 3AC 110A, 55kW (75HP), FSF
6SL3210-1SE31-5AA0 PM340 380 ... 480 C 3AC 145A, 75kW (100HP), FSF
6SL3210-1SE31-5UA0 PM340 380 ... 480 C 3AC 145A, 75kW (100HP), FSF
MLFB DESCRIPTION MLFB DESCRIPTION MLFB DESCRIPTION
Overview of SINAMICS S110 Safety Intergrated Functions & Associated Boundary Conditions
6SL3074-0AA10-0AA0For connecting not DRIVE-CliQ motors with encoders
Overview cables for SINAMICS S110
6SL3055-0AA00-5BA2For connecting not
DRIVE-CliQ motors with resolvers
7www.ued.co.uk
![Page 8: Underwoods](https://reader033.vdocument.in/reader033/viewer/2022042901/568c35ec1a28ab023596148e/html5/thumbnails/8.jpg)
Systematic advancement
SIRIUS comprises the complete portfolio of industrial controls and has been a trendsetter in this field from the very start. This leading position is once more proven by the tried-and-tested modular system with its latest innovations for the main and control circuit.
The consistent advancement of SIRIUS addresses current market requirements even more closely – above all regarding reduced variance, increased flexibility and cost and time savings. Your advantage: improved productivity and efficiency within your company.
Forget wiring: simply Click ’n’ Go!
With the components of the SIRIUS Modular System, you opt for perfectly matched and flexibly combinable components which offer unprecedented ease of assembly: just plug on, and connect –click ’n’ go! As this concept does away with laborious wiring and eliminates the risk of wiring faults, you will benefit from considerable time and cost savings.
The most important advancements of the SIRIUS portfolio are presented on the following pages. These innovations will help you to substantially reduce your control panel assembly costs.
The new SIRIUS Modular System: thoroughly innovated
Sizes S00 and S0 (up to 40 A) of the SIRIUS Modular System were completely redesigned in terms of the main and control circuit.
The innovated basic components such as circuit breakers and contactors offer numerous advantages for system optimization– both today and in the future. In addition, these innovations support maximum flexibility.
No matter whether direct-on-line, reversing or star-delta start; for self-assembly, as tested combination or as “all-in-one” solution with the new Compact Starter, whether for soft starting or frequent switching applications: the modular system offers the suitable solution for all requirements.
The aspect of increased system availability was also a focus for the range’s redevelopment. For example, the components of the SIRIUS Modular System will even allow for application monitoring with minimum costs in the future. This way, targeted application monitoring is substantially simplified – with current monitoring relays directly integrated in the load feeder, via the PLC or via the connection of load feeders to AS-Interface or IO-Link.
These innovations perfectly round off the bottom end of the present Modular System – sizes S2–S12, up to 250 kW at 400 V – and offer numerous new options for control panel assembly.
Assembly of a star-delta starter with function modules
How Can Control Panels be
Assembled Faster?
SIRIUS INNOVATIONS
8 www.ued.co.uk
![Page 9: Underwoods](https://reader033.vdocument.in/reader033/viewer/2022042901/568c35ec1a28ab023596148e/html5/thumbnails/9.jpg)
SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A
For motor protectionCLASS 10, without auxiliary switches1)
PU (UNIT, SET, M) =1 PS* =1 unit PG =101
1) The 3RV20 .1-..A.0 motor starter protectors up to 32 A are also available with ring terminal lug connection. The Order No. must be changed in the 11th position to "4": e. g. 3RV20 11-0AA 40.
2) Guide value for 4-pole standard motors at AC 50 Hz 400 V. The actual starting and rated data of the motor to be protected must be considered when selecting the units.
Rated current
Suitable for induction motors2) with P
Setting range for thermal overload releases
Instanta-neous electronicreleases
Short-circuit breaking capacity at 400 V AC
DT Screw terminals Weightper PUapprox.
DT Spring-type terminals
Weightper PUapprox.
I n I cu Order No. Price per PU
Order No. Price per PU
A kW A A kA kg kg
Size S000.16 0.04 0.11 ... 0.16 2.1 100 A 3RV20 11-0AA10 0.260 B 3RV20 11-0AA20 0.2800.2 0.06 0.14 ... 0.2 2.6 100 A 3RV20 11-0BA10 0.260 B 3RV20 11-0BA20 0.2900.25 0.06 0.18 ... 0.25 3.3 100 A 3RV20 11-0CA10 0.260 B 3RV20 11-0CA20 0.2900.32 0.09 0.22 ... 0.32 4.2 100 A 3RV20 11-0DA10 0.260 B 3RV20 11-0DA20 0.280
0.4 0.09 0.28 ... 0.4 5.2 100 A 3RV20 11-0EA10 0.260 B 3RV20 11-0EA20 0.2900.5 0.12 0.35 ... 0.5 6.5 100 A 3RV20 11-0FA10 0.260 B 3RV20 11-0FA20 0.2900.63 0.18 0.45 ... 0.63 8.2 100 A 3RV20 11-0GA10 0.260 B 3RV20 11-0GA20 0.2800.8 0.18 0.55 ... 0.8 10 100 A 3RV20 11-0HA10 0.260 B 3RV20 11-0HA20 0.280
1 0.25 0.7 ... 1 13 100 A 3RV20 11-0JA10 0.320 B 3RV20 11-0JA20 0.3501.25 0.37 0.9 ... 1.25 16 100 A 3RV20 11-0KA10 0.320 B 3RV20 11-0KA20 0.3501.6 0.55 1.1 ... 1.6 21 100 A 3RV20 11-1AA10 0.320 B 3RV20 11-1AA20 0.3502 0.75 1.4 ... 2 26 100 A 3RV20 11-1BA10 0.320 B 3RV20 11-1BA20 0.350
2.5 0.75 1.8 ... 2.5 33 100 A 3RV20 11-1CA10 0.320 B 3RV20 11-1CA20 0.3503.2 1.1 2.2 ... 3.2 42 100 A 3RV20 11-1DA10 0.330 B 3RV20 11-1DA20 0.3504 1.5 2.8 ... 4 52 100 A 3RV20 11-1EA10 0.320 B 3RV20 11-1EA20 0.3505 1.5 3.5 ... 5 65 100 A 3RV20 11-1FA10 0.330 B 3RV20 11-1FA20 0.350
6.3 2.2 4.5 ... 6.3 82 100 A 3RV20 11-1GA10 0.330 B 3RV20 11-1GA20 0.3608 3 5.5 ... 8 104 100 A 3RV20 11-1HA10 0.330 B 3RV20 11-1HA20 0.36010 4 7 ... 10 130 100 A 3RV20 11-1JA10 0.330 B 3RV20 11-1JA20 0.36012.5 5.5 9 ... 12.5 163 100 A 3RV20 11-1KA10 0.330 B 3RV20 11-1KA20 0.36016 7.5 11 ... 16 208 55 A 3RV20 11-4AA10 0.340 B 3RV20 11-4AA20 0.360
Size S016 7.5 11 ... 16 208 55 A 3RV20 21-4AA10 0.340 B 3RV20 21-4AA20 0.39020 7.5 14 ... 20 260 55 A 3RV20 21-4BA10 0.340 B 3RV20 21-4BA20 0.40022 11 17 ... 22 286 55 A 3RV20 21-4CA10 0.340 B 3RV20 21-4CA20 0.39025 11 20 ... 25 325 55 A 3RV20 21-4DA10 0.340 B 3RV20 21-4DA20 0.400
28 15 23 ... 28 364 55 A 3RV20 21-4NA10 0.350 B 3RV20 21-4NA20 0.41032 15 27 ... 32 400 55 A 3RV20 21-4EA10 0.350 B 3RV20 21-4EA20 0.410
36 18.5 30 ... 36 432 20 A 3RV20 21-4PA10 0.360 --40 18.5 34 ... 40 480 20 A 3RV20 21-4FA10 0.360 --
3RV20 11-0EA20 3RV20 21-4AA10 3RV20 21-4AA203RV20 11-0AA10
9www.ued.co.uk
![Page 10: Underwoods](https://reader033.vdocument.in/reader033/viewer/2022042901/568c35ec1a28ab023596148e/html5/thumbnails/10.jpg)
SIRIUS 3RV2 Motor Starter Protectors up to 40 A
Mountable accessoriesPU (UNIT, SET, M) =1 PS* =1 unit PG =101
1) One transverse auxiliary switch and one lateral auxiliary switch can be attached per motor starter protector. The lateral auxiliary switch with 2 NO + 2 NC is used without a transverse auxiliary switch.
2) This accessory cannot be used for the 3RV27 and 3RV28 motor starter protectors.
3) The 3RV29 auxiliary and signaling switches with 1 NO + 1 NC are also available with ring terminal lug connection. The Order No. must be changed in the 8th position to "4": e. g. 3RV29 01- 4E .
Version
Size
DT Screw terminals Weightper PU
approx.
DT Spring-type terminals
Weightper PU
approx.
Order No. Price per PU
Order No. Price per PU
kg kg
Auxiliary switches 1)
3RV29 01-1E
3RV29 01-2E
3RV29 01-1G
Transverse auxiliary switches for front mounting
A0S ,00SOC1 3RV29 01-1D 0.014 --1 NO + 1 NC 3) A 3RV29 01-1E 0.016 A 3RV29 01-2E 0.016
AON2 3RV29 01-1F 0.017 A 3RV29 01-2F 0.017
Solid-state compatible transverse auxiliary switches for mounting on the front, for operation in dusty atmosphere and in solid-state circuits with low operating currents
A0S ,00SOC1 3RV29 01-1G 0.015 --
3RV29 01-0H
Covers for transverse auxiliary switches
S00, S0 A 3RV29 01-0H 0.001 --
3RV29 01-1A
3RV29 01-2A
Lateral auxiliary switches mountable on the left
1 NO + 1 NC 3) S00, S0 A 3RV29 01-1A 0.036 A 3RV29 01-2A 0.035AON2 3RV29 01-1B 0.037 A 3RV29 01-2B 0.035ACN2 3RV29 01-1C 0.037 A 3RV29 01-2C 0.035ACN2 + ON2 3RV29 01-1J 0.066 --
Signaling switches 2)
3RV29 21-1M
3RV29 21-2M
Signaling switches3) One signaling switch can be mounted on the left per motor starter protector.
Separate tripped and short-circuit alarms, 1 NO + 1 NC each.
S0 A 3RV29 21-1M 0.068 A 3RV29 21-2M 0.070
Isolator modules 2)
3RV29 28-1A with padlock
Isolator modules Visible isolating distance for isolating individual motor starter protectors from the network, lockable in disconnected position.
S0, S00 X 3RV29 28-1A 0.132 --
For motorstarter protectors
10 www.ued.co.uk
![Page 11: Underwoods](https://reader033.vdocument.in/reader033/viewer/2022042901/568c35ec1a28ab023596148e/html5/thumbnails/11.jpg)
SIRIUS 3RV2 Motor Starter Protectors up to 40 A
Busbar Accessories
1) Not suitable for 3RV21 motor starter protectors for motor protection with overload relay function and for 3RV27 and 3RV28 circuit breakers according to UL 489 / CSA C22.2 No.5-02.
2) Approved up to 32 A.
1) This terminal is connected in place of a switch, please take the space requirement into account.
Modularspacing
Number of motor starter protectors that can be connected
Rated current I n at 690 V Size
DT Order No. Price per PU
PU(UNIT,
SET, M)
PS* PG Weightper PU
approx.
Without lateral accessories
Incl.lateral auxiliary switch
Incl. auxiliary release
Amm kg
Three-phase busbars1)2)
3RV19 15-1AB
3RV19 15-1BB
3RV19 15-1CB
3RV19 15-1DB
For feeding several motor starter protectors with screw terminals, mounted side by side on standard mounting rails, insulated, with touch protection.
45 2 -- -- 63 S00, S01)
} 3RV19 15-1AB 1 1 unit 101 0.0440S ,00S3
1)} 3RV19 15-1BB 1 1 unit 101 0.071
0S ,00S41)
} 3RV19 15-1CB 1 1 unit 101 0.0990S ,00S5
1)} 3RV19 15-1DB 1 1 unit 101 0.124
55 -- 2 -- 63 S00, S01)
} 3RV19 15-2AB 1 1 unit 101 0.0480S ,00S3
1)} 3RV19 15-2BB 1 1 unit 101 0.079
0S ,00S41)
} 3RV19 15-2CB 1 1 unit 101 0.1110S ,00S5
1)} 3RV19 15-2DB 1 1 unit 101 0.140
63 -- -- 2 63 S00, S01) } 3RV19 15-3AB 1 1 unit 101 0.0524 S00, S0
1)} 3RV19 15-3CB 1 1 unit 101 0.120
Conductor cross-section Tighteningtorque
Size
DT Order No. Price per PU
PU(UNIT,
SET, M)
PS* PG Weightper PU
approx.Solid or stranded
Finely stranded with end sleeve
AWG cables, solid or stranded
mm2 mm2 AWG Nm kg
Three-phase feeder terminals
3RV29 25-5AB
3RV29 15-5B
Connection from top2.5 ... 16 2.5 ... 16 10 ... 4 3 ... 4 S00, S0 X 3RV29 25-5AB 1 1 unit 101 0.043
Connection from bottom 1)
2.5 ... 16 2.5 ... 16 10 ... 4 Input: 4, Output: 2 ... 2.5
S00, S0 X 3RV29 15-5B 1 1 unit 101 0.093
Three-phase feeder terminals for constructing "Type E Starters"
3RV29 25-5EB
Connection from top2.5 ... 16 2.5 ... 16 10 ... 4 3 ... 4 S00, S0 X 3RV29 25-5EB 1 1 unit 101 0.044
Version
Size
DT Order No. Price per PU
PU(UNIT,
SET, M)
PS* PG Weightper PUapprox.
kg
Covers for connection tags
3RV19 15-6AB
Touch protection for empty positions
S00, S0 } 3RV19 15-6AB 1 10 units 101 0.003
For motorstarter protectors
For motorstarter protectors
For motorstarter protectors
11www.ued.co.uk
![Page 12: Underwoods](https://reader033.vdocument.in/reader033/viewer/2022042901/568c35ec1a28ab023596148e/html5/thumbnails/12.jpg)
Link modules
1) The link modules from motor starter protector to contactor cannot be used for 3RV2. 21-4PA1., 3RV2. 21-4FA1., 3RV27 and 3RV28 motor starter protectors/circuit breakers.
2) A spacer for height compensation on AC contactors size S0 is optionally available
Note:Link modules can be used up to max. 32 A.
Fixing accessories
3RV29 28-0B
Push-in lugsFor screwing the motor starter protector onto mounting plates.
For each motor starter protector, 2 units are required.
S00, S0 A 3RV29 28-0B 100 10 units 101 0.100
Tools for opening spring-type terminals
3RA29 08-1A
Screwdrivers for all SIRIUS devices with spring-type terminals
Spring-type terminals
Length approx. 200 mm, 3.0 mm x 0.5 mm, titanium gray/black, partially insulated
S00, S0 A 3RA29 08-1A 1 1 unit 101 0.045
Terminal blocks and phase barriers for "Self-Protected Combination Motor Controllers (Type E)" according to UL 508
3RV29 28-1H
3RV29 28-1K
Note: UL 508 demands for "Combination Motor Controller Type E" 1-inch clearance and 2-inch creepage distance at line side. The following terminal blocks or phase barriers mu st be used in 3RV20 motor starter protectors.
The terminal blocks or phase barriers cannot be used in combination with the 3RV19 .5 three-phase busbars.
Terminal blocks type EFor extended clearance and creepage distances (1 and 2 inch)
S00, S0 X 3RV29 28-1H 1 1 unit 101 0.065
Phase barriers For extended clearance and creepage distances (1 and 2 inch)
S00, S0 A 3RV29 28-1K 1 1 unit 101 0.010
Version For motor starter protectors Size
DT Order No. Price per PU
PU(UNIT,
SET, M)
PS* PG Weightper PU
approx.kg
Actuating voltageContactors
Size DT Order No. Price per PU
PU(UNIT,
SET, M)
PS* PG Weightper PUapprox.
3RT2 contactors
3RV2 motor starter protectors
kg
Link modules for motor starter protector to contactor1)
3RA29 21-1AA00
For mechanical and electrical connection between motor starter protector and contactor with screw terminals
Screw terminals
Single-unit packagingAC/DC S00 S00 } 3RA19 21-1DA00 1 1 unit 101 0.028AC S0 S00/S0 A 3RA29 21-1AA00 1 1 unit 101 0.001DC S0 S00/S0 A 3RA29 21-1BA00 1 1 unit 101 0.001
Multi-unit packagingAC/DC S00 S00 } 3RA19 21-1D 1 10 units 101 0.021AC S0 S00/S0 A 3RA29 21-1A 1 10 units 101 0.001DC S0 S00/S0 A 3RA29 21-1B 1 10 units 101 0.001
3RA29 11-2AA00
For mechanical and electrical connection between motor starter protector and contactor with spring-type terminals
Spring-type terminals
Single-unit packagingAC/DC S00 S00 A 3RA29 11-2AA00 1 1 unit 101 0.040AC 2) S0 S00/S0 A 3RA29 21-2AA00 1 1 unit 101 0.077DC S0 S00/S0 A 3RA29 21-2AA00 1 1 unit 101 0.077
Multi-unit packagingAC/DC S00 S00 A 3RA29 11-2A 1 10 units 101 0.400AC 2) S0 S00/S0 A 3RA29 21-2A 1 10 units 101 0.770DC S0 S00/S0 A 3RA29 21-2A 1 10 units 101 0.770
Spacers 2)
for compensating the height on AC contactors
Single-unit packaging S0 S0 A 3RA29 11-1CA00 1 1 unit 101 0.001Multi-unit packaging S0 S0 A 3RA29 11-1C 1 5 units 101 0.001
SIRIUS 3RV2 Motor Starter Protectors up to 40 A
Mounting Accessories
12 www.ued.co.uk
![Page 13: Underwoods](https://reader033.vdocument.in/reader033/viewer/2022042901/568c35ec1a28ab023596148e/html5/thumbnails/13.jpg)
3RT Power Contractors for Switching Motors AC Operation
3RT20 Contactors, 3-pole, 3 ... 18.5 kWAC Operation
PU (UNIT, SET, M) = 1 PS* = 1 UNIT PG = 101
For contactors with permanently mounted auxiliary switch block please inquire. 1) The 3RT20 contactors are also available with ring terminal lug connection. Please contact your local Siemens representative for information about the special contactor versions with ring terminal lug connection.
2) For size S00: Coil operating range at 50 Hz: 0.8 ... 1.1 × U s , at 60 Hz: 0.85 ... 1.1 × U s .
3RT20 1 . -1A . . . 3RT20 1 . -2A . . . 3RT20 1 . -1AP04-3MA0 3RT20 1 . -2AP04-3MA0
Rated data Auxiliary contacts
Rated control supply voltageU s at 50/60 Hz
DT Screw terminals Weightper PUapprox.
DT Spring-type terminals Weightper PUapprox.
AC-2 and AC-3, Tu : up to 60 °C
AC-1, Tu : 40 °C
Operationalcurrent
I e up to
Rating of induction motors at 50 Hz and
Operationalcurrent
I e up to
Ident. No.
Version Order No. Price per PU
Order No. Price per PU
400 V 400 V 690 VA kW A NO NC V AC kg kg
For screw and snap-on mounting onto TH 35 standard mounting railSize S001)2) Terminal designations according to EN 50012
7 3 18 10 E 1 -- 24 A 3RT20 15-1AB01 0.280A 3RT20 15-2AB01 0.300110 A 3RT20 15-1AF01 0.280B 3RT20 15-2AF01 0.300230 A 3RT20 15-1AP01 0.280A 3RT20 15-2AP01 0.300
01 -- 1 24 A 3RT20 15-1AB02 0.280A 3RT20 15-2AB02 0.3003RT20 15-1AF02 0.280B 3RT20 15-2AF02 0.3003RT20 15-1AP02 0.280B 3RT20 15-2AP02 0.300
9 4 22 10 E 1 -- 24 A 3RT20 16-1AB01 0.280A 3RT20 16-2AB01 0.3003RT20 16-1AF01 0.280B 3RT20 16-2AF01 0.3003RT20 16-1AP01 0.280A 3RT20 16-2AP01 0.300
01 -- 1 24 A 3RT20 16-1AB02 0.280B 3RT20 16-2AB02 0.3003RT20 16-1AF02 0.280B 3RT20 16-2AF02 0.3003RT20 16-1AP02 0.280B 3RT20 16-2AP02 0.300
12 5.5 22 10 E 1 -- 24 A 3RT20 17-1AB01 0.280B 3RT20 17-2AB01 0.3003RT20 17-1AF01 0.280B 3RT20 17-2AF01 0.3003RT20 17-1AP01 0.280B 3RT20 17-2AP01 0.300
01 -- 1 24 A 3RT20 17-1AB02 0.280B 3RT20 17-2AB02 0.3003RT20 17-1AF02 0.280B 3RT20 17-2AF02 0.3003RT20 17-1AP02 0.280B 3RT20 17-2AP02 0.300
16 7.5 22 10 E 1 -- 24 B 3RT20 18-1AB01 0.280B 3RT20 18-2AB01 0.3003RT20 18-1AF01 0.280B 3RT20 18-2AF01 0.3003RT20 18-1AP01 0.280B 3RT20 18-2AP01 0.300
01 -- 1 24 B 3RT20 18-1AB02 0.280B 3RT20 18-2AB02 0.3003RT20 18-1AF02 0.280B 3RT20 18-2AF02 0.3003RT20 18-1AP02 0.280B 3RT20 18-2AP02 0.300
Size S00 2)
With permanently mounted auxiliary switch blockTerminal designations according to EN 50012
7 3 18 22 E 2 2 230 B 3RT20 15-1AP04-3MA0 0.280B 3RT20 15-2AP04-3MA0 0.300
9 4 22 22 E 2 2 230 B 3RT20 16-1AP04-3MA0 0.280B 3RT20 16-2AP04-3MA0 0.300
12 5.5 22 22 E 2 2 230 B 3RT20 17-1AP04-3MA0 0.280B 3RT20 17-2AP04-3MA0 0.300
16 7.5 22 22 E 2 2 230 B 3RT20 18-1AP04-3MA0 0.280B 3RT20 18-2AP04-3MA0 0.300
110 A230 A
110 A230 A
110 A230 A
110 A230 A
110 B230 A
110 B230 A
110 B230 A
13www.ued.co.uk
![Page 14: Underwoods](https://reader033.vdocument.in/reader033/viewer/2022042901/568c35ec1a28ab023596148e/html5/thumbnails/14.jpg)
3RT Power Contractors for Switching Motors AC Operation
3RT20 Contactors, 3-pole, 3 ... 18.5 kWAC Operation
PU (UNIT, SET, M) = 1 PS* = 1 UNIT PG = 101
For contactors with permanently mounted auxiliary switch block please inquire. 1) The 3RT20 contactors are also available with ring terminal lug connection. Please contact your local Siemens representative for information about the special contactor versions with ring terminal lug connection.
2) Order No. for the auxiliary switch block (removable): 3RH29 11-1HA11 (1 NO + 1 NC according to EN 50012; 22E).
40.A2-.2 02TR340.A1-.2 02TR300.A2-.2 02TR300.A1-.2 02TR3
Rated data Auxiliary contacts
Rated control supply volt-age U s at 50 Hz
DT Screw terminals Weightper PUapprox.
DT Spring-type terminals Weightper PUapprox.
AC-2 and AC-3, T u: up to 60 °C
AC-1, T u: 40 °C
Opera-tional current I e up to
Rating of induction motors at 50 Hz and
Opera-tional current I e up to
Ident. No.
Version Order No. Price per PU
Order No. Price per PU
400 V 400 V 690 V
A kW A NO NC V AC kg kg
For screw and snap-on mounting onto TH 35 standard mounting railSize S0 1)
12 5.5 40 11 E 1 1 24 A 3RT20 24-1AB00 0.460 B 3RT20 24-2AB00 0.440110 A 3RT20 24-1AF00 0.460 B 3RT20 24-2AF00 0.440230 A 3RT20 24-1AP00 0.460 B 3RT20 24-2AP00 0.440
17 7.5 40 11 E 1 1 24 A 3RT20 25-1AB00 0.460 B 3RT20 25-2AB00 0.440110 A 3RT20 25-1AF00 0.460 B 3RT20 25-2AF00 0.440230 A 3RT20 25-1AP00 0.460 B 3RT20 25-2AP00 0.440
25 11 40 11 E 1 1 24 A 3RT20 26-1AB00 0.460 A 3RT20 26-2AB00 0.440110 A 3RT20 26-1AF00 0.460 B 3RT20 26-2AF00 0.440230 A 3RT20 26-1AP00 0.460 B 3RT20 26-2AP00 0.440
32 15 50 11 E 1 1 24 B 3RT20 27-1AB00 0.460 B 3RT20 27-2AB00 0.440110 A 3RT20 27-1AF00 0.460 B 3RT20 27-2AF00 0.440230 A 3RT20 27-1AP00 0.460 B 3RT20 27-2AP00 0.440
38 18.5 50 11 E 1 1 24 B 3RT20 28-1AB00 0.460 B 3RT20 28-2AB00 0.440110 B 3RT20 28-1AF00 0.460 B 3RT20 28-2AF00 0.440230 A 3RT20 28-1AP00 0.460 B 3RT20 28-2AP00 0.440
Size S0With mounted auxiliary switch block (removable)
2)
Terminal designations according to EN 50012
12 5.5 40 22 E 2 2 24 B 3RT20 24-1AB04 0.460 B 3RT20 24-2AB04 0.440110 B 3RT20 24-1AF04 0.460 B 3RT20 24-2AF04 0.440230 A 3RT20 24-1AP04 0.460 B 3RT20 24-2AP04 0.440
17 7.5 40 22 E 2 2 24 B 3RT20 25-1AB04 0.460 B 3RT20 25-2AB04 0.440110 B 3RT20 25-1AF04 0.460 B 3RT20 25-2AF04 0.440230 A 3RT20 25-1AP04 0.460 B 3RT20 25-2AP04 0.440
25 11 40 22 E 2 2 24 B 3RT20 26-1AB04 0.460 B 3RT20 26-2AB04 0.440110 B 3RT20 26-1AF04 0.460 B 3RT20 26-2AF04 0.440230 A 3RT20 26-1AP04 0.460 B 3RT20 26-2AP04 0.440
32 15 50 22 E 2 2 24 B 3RT20 27-1AB04 0.460 B 3RT20 27-2AB04 0.440110 B 3RT20 27-1AF04 0.460 B 3RT20 27-2AF04 0.440230 A 3RT20 27-1AP04 0.460 B 3RT20 27-2AP04 0.440
38 18.5 50 22 E 2 2 24 B 3RT20 28-1AB04 0.460 B 3RT20 28-2AB04 0.440110 B 3RT20 28-1AF04 0.460 B 3RT20 28-2AF04 0.440230 A 3RT20 28-1AP04 0.460 B 3RT20 28-2AP04 0.440
14 www.ued.co.uk
![Page 15: Underwoods](https://reader033.vdocument.in/reader033/viewer/2022042901/568c35ec1a28ab023596148e/html5/thumbnails/15.jpg)
3RT Power Contactors for Switching Motors DC Operation
3RT20 Contactors, 3-pole, 3 ... 18.5 kWDC operation · DC solenoid system
PU (UNIT, SET, M) = 1 PS* = 1 UNIT PG = 101
For contactors with permanently mounted auxiliary switch block please inquire. 1) The 3RT20 contactors are also available with ring terminal lug connection. Please contact your local Siemens representative for information about the special contactor versions with ring terminal lug connection.
0AM3-44BB2-.1 02TR30AM3-44BB1-.1 02TR3...B2-.1 02TR3...B1-.1 02TR3
Rated data Auxiliary contacts
Rated control supply voltageU s
DT Screw terminals Weightper PU
approx.
DT Spring-type terminals Weightper PU
approx.AC-2 and AC-3, Tu : up to 60 °C
AC-1, Tu : 40 °C
Opera-tional current I e up to
Rating of induction motors at 50 Hz and
Opera-tional current I e up to
Ident. No.
Version Order No. Priceper PU
Order No. Priceper PU
400 V 400 V 690 V
A kW A NO NC V DC kg kg
For screw and snap-on mounting onto TH 35 standard mounting railSize S00 1)
Terminal designations according to EN 50012
7 3 18 10 E 1 -- 24 A 3RT20 15-1BB41 0.280 A 3RT20 15-2BB41 0.300220 A 3RT20 15-1BM41 0.280 B 3RT20 15-2BM41 0.300
01 -- 1 24 A 3RT20 15-1BB42 0.280 A 3RT20 15-2BB42 0.300220 B 3RT20 15-1BM42 0.280 B 3RT20 15-2BM42 0.300
9 4 22 10 E 1 -- 24 A 3RT20 16-1BB41 0.280 A 3RT20 16-2BB41 0.300220 B 3RT20 16-1BM41 0.280 B 3RT20 16-2BM41 0.300
01 -- 1 24 A 3RT20 16-1BB42 0.280 A 3RT20 16-2BB42 0.300220 B 3RT20 16-1BM42 0.280 B 3RT20 16-2BM42 0.300
12 5.5 22 10 E 1 -- 24 A 3RT20 17-1BB41 0.280 A 3RT20 17-2BB41 0.300220 B 3RT20 17-1BM41 0.280 B 3RT20 17-2BM41 0.300
01 -- 1 24 A 3RT20 17-1BB42 0.280 A 3RT20 17-2BB42 0.300220 B 3RT20 17-1BM42 0.280 B 3RT20 17-2BM42 0.300
16 7.5 22 10 E 1 -- 24 A 3RT20 18-1BB41 0.280 B 3RT20 18-2BB41 0.300220 B 3RT20 18-1BM41 0.280 B 3RT20 18-2BM41 0.300
01 -- 1 24 A 3RT20 18-1BB42 0.280 B 3RT20 18-2BB42 0.300220 B 3RT20 18-1BM42 0.280 B 3RT20 18-2BM42 0.300
Size S00With permanently mounted auxiliary switch block Terminal designations according to EN 50012
7 3 18 22 E 2 2 24 B 3RT20 15-1BB44-3MA0 0.280 B 3RT20 15-2BB44-3MA0 0.300
9 4 22 22 E 2 2 24 B 3RT20 16-1BB44-3MA0 0.280 B 3RT20 16-2BB44-3MA0 0.300
12 5.5 22 22 E 2 2 24 B 3RT20 17-1BB44-3MA0 0.280 B 3RT20 17-2BB44-3MA0 0.300
16 7.5 22 22 E 2 2 24 B 3RT20 18-1BB44-3MA0 0.280 B 3RT20 18-2BB44-3MA0 0.300
Size S00Contactors with communication interface Terminal designations according to EN 50012
7 3 18 10 E 1 -- 24 B 3RT20 15-1BB41-0CC0 0.280 B 3RT20 15-2BB41-0CC0 0.300
01 -- 1 24 B 3RT20 15-1BB42-0CC0 0.280 B 3RT20 15-2BB42-0CC0 0.300
9 4 22 10 E 1 -- 24 B 3RT20 16-1BB41-0CC0 0.280 B 3RT20 16-2BB41-0CC0 0.300
01 -- 1 24 B 3RT20 16-1BB42-0CC0 0.280 B 3RT20 16-2BB42-0CC0 0.300
12 5.5 22 10 E 1 -- 24 B 3RT20 17-1BB41-0CC0 0.280 B 3RT20 17-2BB41-0CC0 0.300
01 -- 1 24 B 3RT20 17-1BB42-0CC0 0.280 B 3RT20 17-2BB42-0CC0 0.300
16 7.5 22 10 E 1 -- 24 B 3RT20 18-1BB41-0CC0 0.280 B 3RT20 18-2BB41-0CC0 0.300
01 -- 1 24 B 3RT20 18-1BB42-0CC0 0.280 B 3RT20 18-2BB42-0CC0 0.300
15www.ued.co.uk
![Page 16: Underwoods](https://reader033.vdocument.in/reader033/viewer/2022042901/568c35ec1a28ab023596148e/html5/thumbnails/16.jpg)
3RT Power Contactors for Switching Motors DC Operation
3RT20 Contactors, 3-pole, 3 ... 18.5 kWDC operation · DC solenoid system
PU (UNIT, SET, M) = 1 PS* = 1 UNIT PG = 101
For contactors with mounted auxiliary switch block please inquire. 1) The 3RT20 contactors are also available with ring terminal lug connection. Please contact your local Siemens representative for information about the special contactor versions with ring terminal lug connection.
2) Order No. for the auxiliary switch block (removable): 3RH29 11-1HA11 (1 NO + 1 NC according to EN 50012; 22E).
44.B2-.2 02TR344.B1-.2 02TR304.B2-.2 02TR304.B1-.2 02TR3
Rated data Auxiliary contacts
Rated control supply voltageUs
DT Screw terminals Weightper PU
approx.
DT Spring-type terminals Weightper PU
approx.AC-2 and AC-3, T u : up to 60 °C
AC-1, T u : 40 °C
Operationalcurrent
I e up to
Rating of induction motors at 50 Hz and
Operationalcurrent
I e up to
Ident. No.
Version Order No. Price per PU
Order No. Price per PU
400 V 400 V 690 V
A kW A NO NC V DC kg kg
For screw and snap-on mounting onto TH 35 standard mounting railSize S0 1)
12 5.5 40 11 E 1 1 24 A 3RT20 24-1BB40 0.580 A 3RT20 24-2BB40 0.620220 B 3RT20 24-1BM40 0.580 B 3RT20 24-2BM40 0.620
17 7.5 40 11 E 1 1 24 A 3RT20 25-1BB40 0.580 A 3RT20 25-2BB40 0.620220 B 3RT20 25-1BM40 0.580 B 3RT20 25-2BM40 0.620
25 11 40 11 E 1 1 24 A 3RT20 26-1BB40 0.580 A 3RT20 26-2BB40 0.620220 B 3RT20 26-1BM40 0.580 B 3RT20 26-2BM40 0.620
32 15 50 11 E 1 1 24 A 3RT20 27-1BB40 0.580 B 3RT20 27-2BB40 0.620220 B 3RT20 27-1BM40 0.580 B 3RT20 27-2BM40 0.620
38 18.5 50 11 E 1 1 24 A 3RT20 28-1BB40 0.580 B 3RT20 28-2BB40 0.620220 B 3RT20 28-1BM40 0.580 B 3RT20 28-2BM40 0.620
Size S0With mounted auxiliary switch block (removable)2) Terminal designations according to DIN 50012
12 5.5 40 22 E 2 2 24 A 3RT20 24-1BB44 0.580 B 3RT20 24-2BB44 0.620
17 7.5 40 22 E 2 2 24 A 3RT20 25-1BB44 0.580 B 3RT20 25-2BB44 0.620
25 11 40 22 E 2 2 24 A 3RT20 26-1BB44 0.580 B 3RT20 26-2BB44 0.620
32 15 50 22 E 2 2 24 A 3RT20 27-1BB44 0.580 B 3RT20 27-2BB44 0.620
38 18.5 50 22 E 2 2 24 A 3RT20 28-1BB44 0.580 B 3RT20 28-2BB44 0.620
16 www.ued.co.uk
![Page 17: Underwoods](https://reader033.vdocument.in/reader033/viewer/2022042901/568c35ec1a28ab023596148e/html5/thumbnails/17.jpg)
PU (UNIT, SET, M) = 1PS* = 1 unitPG = 101
1) The 3RH29 auxiliary switches are also available with ring terminal lugconnection. In the 8th position of the Order No. the "1" must be replaced with "4" , e. g. 3RH29 11-1HA22 -> 3RH29 11- 4HA22.
2) Mounting permitted only on basic units which do not have an integrated NC contact.
3RH29 11-1HA. . 3RH29 11-2HA. . 3RH29 11-1LA. . 3RH29 11-1MA. . 3RH29 11-1AA. . 3RH29 11-1BA. .3RH29 11-1FA. . 3RH29 11-2FA. .
For contactors Auxiliary contacts DT Screw terminals Weightper PUapprox.
DT Spring-type terminals Weightper PUapprox.
Ident. No. Version
Order No. Price per PU
Order No. Priceper PU
CNONCNONepyT kg kg
Auxiliary switch blocks for snapping onto the front according to EN 50012 (also compliant with the requirements according to EN 50005) Size S00
1)
For assembling contactors with 2, 3, 4 or 5 auxiliary contacts3RT20 1Ident. No. 10 E
11 E -- 1 -- -- A 3RH29 11-1HA01 0.050 A 3RH29 11-2HA01 0.05012 E -- 2 -- -- A 3RH29 11-1HA02 0.050 A 3RH29 11-2HA02 0.05013 E -- 3 -- -- C 3RH29 11-1HA03 0.050 C 3RH29 11-2HA03 0.050
21 E 1 1 -- -- A 3RH29 11-1HA11 0.050 A 3RH29 11-2HA11 0.05022 E 1 2 -- -- A 3RH29 11-1HA12 0.050 A 3RH29 11-2HA12 0.05023 E 1 3 -- -- A 3RH29 11-1HA13 0.050 A 3RH29 11-2HA13 0.050
31 E 2 1 -- -- C 3RH29 11-1HA21 0.050 C 3RH29 11-2HA21 0.05032 E 2 2 -- -- A 3RH29 11-1HA22 0.050 A 3RH29 11-2HA22 0.05041 E 3 1 -- -- A 3RH29 11-1HA31 0.050 A 3RH29 11-2HA31 0.050
Size S0 1)
For assembling contactors with 3, 4 or 5 auxiliary contacts3RT20 2 12 E -- 1 -- -- A 3RH29 11-1HA01 0.050 A 3RH29 11-2HA01 0.050
13 E -- 2 -- -- A 3RH29 11-1HA02 0.050 A 3RH29 11-2HA02 0.050
21 E 1 -- -- -- C 3RH29 11-1HA10 0.050 C 3RH29 11-2HA10 0.05022 E 1 1 -- -- A 3RH29 11-1HA11 0.050 A 3RH29 11-2HA11 0.05023 E 1 2 -- -- A 3RH29 11-1HA12 0.050 A 3RH29 11-2HA12 0.050
31 E 2 -- -- -- A 3RH29 11-1HA20 0.050 A 3RH29 11-2HA20 0.05032 E 2 1 -- -- C 3RH29 11-1HA21 0.050 C 3RH29 11-2HA21 0.05041 E 3 -- -- -- C 3RH29 11-1HA30 0.050 C 3RH29 11-2HA30 0.050
Auxiliary switch blocks for snapping onto the front according to EN 50005Sizes S00 and S0
2 or 4-pole auxiliary switch blocks for assembling contactors with 3, 5 or 6 auxiliary contacts3RT2. 1, 3RT2. 2, 3RH21, 3RH24
40 4 -- -- -- A 3RH29 11-1FA40 0.050 A 3RH29 11-2FA40 0.050042) -- 4 -- -- C 3RH29 11-1FA04 0.050 C 3RH29 11-2FA04 0.05011 U -- -- 1 1 A 3RH29 11-1FB11 0.050 A 3RH29 11-2FB11 0.04022 U -- -- 2 2 A 3RH29 11-1FC22 0.050 A 3RH29 11-2FC22 0.05011, 11 U 1 1 1 1 A 3RH29 11-1FB22 0.050 A 3RH29 11-2FB22 0.050
1- and 2-pole auxiliary switch blocks with cable entry from one side• Cable entry from above
3RT2. 1, 3RT2. 2, 3RH21, 3RH24
-- 1 -- -- -- A 3RH29 11-1AA10 0.020 ---- -- 1 -- -- A 3RH29 11-1AA01 0.020 ---- 1 1 -- -- A 3RH29 11-1LA11 0.050 ---- 2 -- -- -- A 3RH29 11-1LA20 0.050 --• Cable entry from below
3RT2. 1, 3RT2. 2, 3RH21, 3RH24
-- 1 -- -- -- A 3RH29 11-1BA10 0.020 ---- -- 1 -- -- A 3RH29 11-1BA01 0.020 ---- 1 1 -- -- A 3RH29 11-1MA11 0.050 ---- 2 -- -- -- A 3RH29 11-1MA20 0.050 --
For 3RT2, 3RH2 Contactors and Contactor Relays
Auxiliary Switch Blocks
17www.ued.co.uk
![Page 18: Underwoods](https://reader033.vdocument.in/reader033/viewer/2022042901/568c35ec1a28ab023596148e/html5/thumbnails/18.jpg)
3RU21 thermal overload relays for mounting onto contactor, CLASS 10
Features and technical speci�cations:• Screw, spring-type or ring terminal lug connection
1)
• Overload and phase failure protection• Auxiliary contacts 1 NO + 1 NC• Manual and automatic RESET• Switch position indicators• TEST function• STOP button• Sealable covers (optional accessory)
• Terminal covers for devices with ring terminal lug connection (optional accessory)
PU (UNIT, SET, M) =1 PS* =1 unit PG =101
1)The 3RU21 overload relays are also available with ring terminal lug connection.
The Order No. must be changed in the 10th position to "J": e. g. 3RU21 16-0A J0. 2)
Observe maximum rated operational current of the devices.
3) Guide value for 4-pole standard motors at AC 50 Hz 400 V. The actual starting and rated data of the motor to be protected must be considered when selecting the units.
4) Maximum protection by fuse for overload relay, type of coordination 2.
Size contactor2)
Rating for induction motor, rated value 3)
Set current value of the inverse-time delayed over-load release
Short-circuit protection with fuse, type of coordination 2, gG operational class 4)
DT Screw terminals Weightper PUapprox.
DT Spring-type terminals
Weightper PUapprox.
Order No. Price per PU
Order No. Price per PU
kW A A kg kg
Size S00S00 0.04 0.11 ... 0.16 0.5 A 3RU21 16-0AB0 0.130 B 3RU21 16-0AC0 0.150
0.06 0.14 ... 0.2 1 A 3RU21 16-0BB0 0.130 B 3RU21 16-0BC0 0.1500.06 0.18 ... 0.25 1 A 3RU21 16-0CB0 0.130 B 3RU21 16-0CC0 0.1500.09 0.22 ... 0.32 1.6 A 3RU21 16-0DB0 0.130 B 3RU21 16-0DC0 0.150
0.09 0.28 ... 0.4 2 A 3RU21 16-0EB0 0.130 B 3RU21 16-0EC0 0.1500.12 0.35 ... 0.5 2 A 3RU21 16-0FB0 0.130 B 3RU21 16-0FC0 0.1500.18 0.45 ... 0.63 2 A 3RU21 16-0GB0 0.130 B 3RU21 16-0GC0 0.1500.18 0.55 ... 0.8 4 A 3RU21 16-0HB0 0.130 B 3RU21 16-0HC0 0.150
0.25 0.7 ... 1 4 A 3RU21 16-0JB0 0.130 B 3RU21 16-0JC0 0.1500.37 0.9 ... 1.25 4 A 3RU21 16-0KB0 0.130 B 3RU21 16-0KC0 0.1500.55 1.1 ... 1.6 6 A 3RU21 16-1AB0 0.130 B 3RU21 16-1AC0 0.1500.75 1.4 ... 2 6 A 3RU21 16-1BB0 0.130 B 3RU21 16-1BC0 0.150
0.75 1.8 ... 2.5 10 A 3RU21 16-1CB0 0.130 B 3RU21 16-1CC0 0.1501.1 2.2 ... 3.2 10 A 3RU21 16-1DB0 0.130 B 3RU21 16-1DC0 0.1501.5 2.8 ... 4 16 A 3RU21 16-1EB0 0.130 B 3RU21 16-1EC0 0.1501.5 3.5 ... 5 20 A 3RU21 16-1FB0 0.130 B 3RU21 16-1FC0 0.150
2.2 4.5 ... 6.3 20 A 3RU21 16-1GB0 0.130 B 3RU21 16-1GC0 0.1503 5.5 ... 8 25 A 3RU21 16-1HB0 0.130 B 3RU21 16-1HC0 0.1504 7 ... 10 35 A 3RU21 16-1JB0 0.130 B 3RU21 16-1JC0 0.1505.5 9 ... 12.5 35 A 3RU21 16-1KB0 0.130 B 3RU21 16-1KC0 0.150
7.5 11 ... 16 40 A 3RU21 16-4AB0 0.130 B 3RU21 16-4AC0 0.150
Size S0S0 0.75 1.8 ... 2.5 10 A 3RU21 26-1CB0 0.160 B 3RU21 26-1CC0 0.220
1.1 2.2 ... 3.2 10 A 3RU21 26-1DB0 0.160 B 3RU21 26-1DC0 0.2201.5 2.8 ... 4 16 A 3RU21 26-1EB0 0.160 B 3RU21 26-1EC0 0.2201.5 3.5 ... 5 20 A 3RU21 26-1FB0 0.160 B 3RU21 26-1FC0 0.220
2.2 4.5 ... 6.3 20 A 3RU21 26-1GB0 0.160 B 3RU21 26-1GC0 0.2203 5.5 ... 8 25 A 3RU21 26-1HB0 0.160 B 3RU21 26-1HC0 0.2204 7 ... 10 35 A 3RU21 26-1JB0 0.160 B 3RU21 26-1JC0 0.2205.5 9 ... 12.5 35 A 3RU21 26-1KB0 0.160 B 3RU21 26-1KC0 0.220
7.5 11 ... 16 40 A 3RU21 26-4AB0 0.160 A 3RU21 26-4AC0 0.2207.5 14 ... 20 50 A 3RU21 26-4BB0 0.160 A 3RU21 26-4BC0 0.22011 17 ... 22 63 A 3RU21 26-4CB0 0.160 A 3RU21 26-4CC0 0.22011 20 ... 25 63 A 3RU21 26-4DB0 0.160 A 3RU21 26-4DC0 0.220
15 23 ... 28 63 A 3RU21 26-4NB0 0.160 A 3RU21 26-4NC0 0.22015 27 ... 32 80 A 3RU21 26-4EB0 0.160 A 3RU21 26-4EC0 0.22018.5 30 ... 36 80 A 3RU21 26-4PB0 0.160 A 3RU21 26-4PC0 0.22018.5 34 ... 40 80 A 3RU21 26-4FB0 0.160 A 3RU21 26-4FC0 0.220
3RU21 16-4AB0 3RU21 16-4AC0 3RU21 26-4FB0 3RU21 26-4AC0
SIRIUS 3R02 Thermal Overload Relays
3RU21 for standard applications
18 www.ued.co.uk
![Page 19: Underwoods](https://reader033.vdocument.in/reader033/viewer/2022042901/568c35ec1a28ab023596148e/html5/thumbnails/19.jpg)
Non-
fuse
d, e
lect
rom
echa
nica
l sw
itchi
ng d
esig
nDe
sign
up
to 7
.5kW
(S00
)
Non
-fuse
d, e
lect
rom
echa
nica
l sw
itchi
ng d
esig
n
19www.ued.co.uk
![Page 20: Underwoods](https://reader033.vdocument.in/reader033/viewer/2022042901/568c35ec1a28ab023596148e/html5/thumbnails/20.jpg)
SIRI
US In
nova
tion
s Siz
e S0
0
20 www.ued.co.uk
![Page 21: Underwoods](https://reader033.vdocument.in/reader033/viewer/2022042901/568c35ec1a28ab023596148e/html5/thumbnails/21.jpg)
SIRI
US In
nova
tion
s Siz
e S0
0 w
ith
Mon
itorin
g Re
lay
21www.ued.co.uk
![Page 22: Underwoods](https://reader033.vdocument.in/reader033/viewer/2022042901/568c35ec1a28ab023596148e/html5/thumbnails/22.jpg)
18.5
kW (S
0) d
esig
n
N
on-fu
sed,
ele
ctro
mec
hani
cal s
witc
hing
des
ign
22 www.ued.co.uk
![Page 23: Underwoods](https://reader033.vdocument.in/reader033/viewer/2022042901/568c35ec1a28ab023596148e/html5/thumbnails/23.jpg)
SIRI
US In
nova
tion
s Siz
e S0
23www.ued.co.uk
![Page 24: Underwoods](https://reader033.vdocument.in/reader033/viewer/2022042901/568c35ec1a28ab023596148e/html5/thumbnails/24.jpg)
Com
mun
icat
ions
– g
ener
al in
form
atio
n an
d co
ntac
tors
24 www.ued.co.uk
![Page 25: Underwoods](https://reader033.vdocument.in/reader033/viewer/2022042901/568c35ec1a28ab023596148e/html5/thumbnails/25.jpg)
Func
tion
mod
ules
for m
ount
ing
on 3
RT2
cont
acto
rs a
nd fo
r int
erfa
cing
the
cont
rol s
yste
m
25www.ued.co.uk
![Page 26: Underwoods](https://reader033.vdocument.in/reader033/viewer/2022042901/568c35ec1a28ab023596148e/html5/thumbnails/26.jpg)
Acce
ssor
ies f
or 3
RT20
1 co
ntac
tors
(S00
)
26 www.ued.co.uk
![Page 27: Underwoods](https://reader033.vdocument.in/reader033/viewer/2022042901/568c35ec1a28ab023596148e/html5/thumbnails/27.jpg)
FRON
T MOU
NTIN
G AU
XILI
ARY
CONT
ACTS
FOR
COM
MEN
TVE
RSIO
NOR
DER
NO.
SCRE
W CO
NNEC
TION
ORDE
R NO
. SP
RING
-LOA
DED
CONN
ECTI
ON
ORDE
R NO
. RI
NG CA
BLE L
UG
CONN
ECTI
ON3R
T2 co
ntac
tors
Stan
dard
see t
abul
ar ov
ervie
w on
pag
e 5�.
Com
mun
icatio
nse
e pag
e 16
1-po
le au
xiliar
y con
tact
blo
ck,
cabl
e ent
ry fr
om th
e top
1NO
3RH2
911-
1AA1
0–
–3R
H291
1-1A
A01
––
2-po
le au
xiliar
y con
tact
blo
ck,
cabl
e ent
ry fr
om th
e top
1NO
+ 1N
C3R
H291
1-1L
A11
––
2NO
3RH2
911-
1LA2
0–
–1-
pole
auxil
iary c
onta
ct b
lock
, ca
ble e
ntry
from
the b
otto
m1N
O3R
H291
1-1B
A10
––
1NC
3RH2
911-
1BA0
1–
–2-
pole
auxil
iary c
onta
ct b
lock
, ca
ble e
ntry
from
the b
otto
m1N
O +
1NC
3RH2
911-
1MA1
12N
O3R
H291
1-1M
A20
4-po
le au
xiliar
y con
tact
blo
ck1)
,
(in co
mpl
iance
with
DIN
EN 50
01
2 and
DIN
EN 50
005)
1NC
3RH2
911-
1HA0
13R
H291
1-2H
A01
3RH2
911-
4HA0
12N
C3R
H291
1-1H
A02
3RH2
911-
2HA0
23R
H291
1-4H
A02
1NO
+ 1N
C3R
H291
1-1H
A11
3RH2
911-
2HA1
13R
H291
1-4H
A11
2NO
+ 2N
C3R
H291
1-1H
A22
3RH2
911-
2HA2
23R
H291
1-4H
A22
1NO
3RH2
911-
1HA1
03R
H291
1-2H
A10
3RH2
911-
4HA1
02N
O3R
H291
1-1H
A20
3RH2
911-
2HA2
03R
H291
1-4H
A20
Auxil
iary c
onta
ct b
lock
s sui
tabl
e for
elec
tronic
com
pone
nts (
2-po
le)
(in co
mpli
ance
with
DIN
EN 50
005)
1NO
+ 1N
C3R
H291
1-1N
F11
3RH2
911-
2NF1
1–
2NO
3RH2
911-
1NF2
03R
H291
1-2N
F20
–2N
C3R
H291
1-1N
F02
3RH2
911-
2NF0
2–
(Fun
ctio
n m
odul
es fo
r mou
ntin
g on
cont
acto
rs an
d fo
r int
erfa
cing
the c
ontro
ller)
Size
-spe
ci�c a
cces
sorie
s for
3RT
2 co
ntac
tors
Auxil
iary c
onta
ct b
lock
s fo
r sid
e mou
ntin
g (o
n th
e rig
ht)
acc.
to D
IN EN
50
005
2NO
3RH2
921-
1DA2
03R
H292
1-2D
A20
–1N
O +
1NC
3RH2
921-
1DA1
13R
H292
1-2D
A11
3RH2
921-
4DA1
1(in
com
plian
ce
with
DIN
EN 50
01
2 and
DIN E
N 50
005)
2NC
3RH2
921-
1DA0
23R
H292
1-2D
A02
–
Auxil
iary c
onta
ct b
lock
for s
ide
mou
ntin
g (o
n th
e rig
ht),
suita
ble
for e
lect
roni
c com
pone
nts
acc.
to D
IN EN
50
005
1NO
+ 1N
C–
3RH2
921-
2DE1
1–
Over
volta
ge lim
iter,
e.g.
varis
tor
(230
V AC
)wi
thou
t LED
AC 12
7–24
0 V3R
T292
6-1B
D00
3RT2
926-
1BD0
03R
T292
6-1B
D00
with
LED
AC 12
7–24
0 V3R
T292
6-1J
L00
3RT2
926-
1JL0
03R
T292
6-1J
L00
Term
inal
mod
ule f
or co
ntac
tor
with
scre
w co
nnec
tion
Adap
ter
AC-3
/400
V:
25 A
3RT1
926-
4RD0
1–
Plug
3RT1
900-
4RE0
1–
Pneu
mat
ic de
lay b
lock
(in
com
plian
ce w
ith D
IN EN
50
005)
1NO
+ 1N
C
0,1 –
30 s
On-d
elay
3RT2
926-
2PA0
1–
–1 –
60 s
3RT2
926-
2PA1
1–
–0,
1 – 30
sO�
-del
ay3R
T292
6-2P
R01
––
1 – 60
s3R
T292
6-2P
R11
––
Coil t
erm
inal
mod
ule
Conn
ectio
n fro
m th
e top
Conn
ectio
n fro
m th
e bot
tom
Diag
onal
conn
ectio
n
3RT2
926-
4RA1
13R
T292
6-4R
A12
–3R
T292
6-4R
B11
3RT2
926-
4RB1
2–
3RT2
926-
4RC1
13R
T292
6-4R
C12
–
1 133 102 129 11
1) M
ore a
uxili
ary c
onta
ct b
lock
s on
requ
est
4
76
58
Acce
ssor
ies f
or 3
RT20
2 co
ntac
tors
(S0)
27www.ued.co.uk
![Page 28: Underwoods](https://reader033.vdocument.in/reader033/viewer/2022042901/568c35ec1a28ab023596148e/html5/thumbnails/28.jpg)
Acce
ssor
ies f
or 3
RV2
mot
or st
arte
r pro
tect
or (S
00, S
0)
28 www.ued.co.uk
![Page 29: Underwoods](https://reader033.vdocument.in/reader033/viewer/2022042901/568c35ec1a28ab023596148e/html5/thumbnails/29.jpg)
TYPE
SIZE
ORDE
R NO
.
3-PH
ASE C
OMB
BUSB
ARS
For s
uppl
ying
seve
ral 3
RV2
mot
or st
arte
r pro
tect
ors
(scr
ew-c
onne
cted
) mou
nted
sid
e by s
ide o
n DI
N ra
ils,
safe
to to
uch
Mod
ular
sp
acin
g45
mm
Mod
ular
sp
acin
g55
mm
Mod
ular
sp
acin
g63
mm
For 2
mot
or st
arte
r pro
tecto
rsS0
0, S0
3RV1
915-
1AB
3RV1
915-
2AB
3RV1
915-
3AB
For 3
mot
or st
arte
r pro
tecto
rsS0
0, S0
3RV1
915-
1BB
3RV1
915-
2BB
–Fo
r 4 m
otor
star
ter p
rote
ctors
S00,
S03R
V191
5-1C
B3R
V191
5-2C
B3R
V191
5-3C
BFo
r 5 m
otor
star
ter p
rote
ctors
S00,
S03R
V191
5-1D
B3R
V191
5-2D
B–
3-PH
ASE S
UPPL
Y TER
MIN
ALS
Conn
ectio
n fro
m th
e top
S00,
S03R
V292
5-5A
BCo
nnec
tion
from
the b
otto
mS0
0, S0
3RV2
915-
5B3-
PHAS
E SUP
PLY T
ERM
INAL
S TO
BUI L
D UP
“TYP
E E ST
ARTE
RS”
Conn
ectio
n fro
m th
e top
S00,
S03R
V292
5-5E
BAC
CESS
ORIE
SCo
ver c
aps f
or co
nnec
ting
lugs
Touc
h pr
otec
tion
for u
nass
igne
d slo
tsS0
0, S0
3RV1
915-
6AB
1 2 3
TYPE
SIZE
VERS
ION
(LEN
GTH)
ORDE
R NO
.
BUSB
AR A
DAPT
ER FO
R 60
MM
SYST
EMFo
r loa
d fe
eder
sRa
ted
curre
nt 25
A fo
r scre
w co
nnec
tion
S00
200 m
m8U
S125
1-5D
S10
For l
oad
feed
ers
Rate
d cu
rrent
25 A
for s
crew
conn
ectio
nS0
0, S0
260 m
m8U
S125
1-5D
T10
For l
oad
feed
ers
Rate
d cu
rrent
40 A
for s
crew
conn
ectio
nS0
260 m
m8U
S125
1-5N
T10
For l
oad
feed
ers
Rate
d cu
rrent
25 A
for s
prin
g-lo
aded
conn
ectio
nS0
0, S0
260 m
m8U
S125
1-5D
T11
For l
oad
feed
ers
Rate
d cu
rrent
40 A
for s
prin
g-lo
aded
conn
ectio
nS0
260 m
m8U
S125
1-5N
T11
ACCE
SSOR
IES
Supp
ort
for s
ide m
ount
ing
on b
usba
r ada
pter,
45 m
m w
ide
200 m
m8U
S125
1-5A
S10
Supp
ort
for s
ide m
ount
ing
on b
usba
r ada
pter,
45 m
m w
ide
260 m
m8U
S125
0- 5
AT10
Side
mod
ule
to w
iden
the b
usba
r ada
pter,
9 m
m w
ide
200 m
m
8US1
998-
2BJ1
0Sp
acer
Fixes
the l
oad
feed
er on
the a
dapt
er8U
S199
8-1B
A10
Vibr
atio
n/sh
ock k
itTo
com
pens
ate s
train
from
hig
her v
ibra
tion
and
shoc
k8U
S199
8-1C
A10
4
3-ph
ase
com
b bu
sbar
s / 8
US b
usba
r ada
pter
s for
supp
ly
29www.ued.co.uk
![Page 30: Underwoods](https://reader033.vdocument.in/reader033/viewer/2022042901/568c35ec1a28ab023596148e/html5/thumbnails/30.jpg)
Considerably reduced wiring in the control circuit, right up to the automation level
With parallel wiring, individual signals are transmitted to the PLC via numerous wires or switching commands are forwarded to the load feeder. In contrast, via AS-Interface or IO-Link, the various signals and switching commands are bundled and transmitted via standardized connections.
No matter whether direct-on-line, reversing, star-delta starter or “all-in-one” Compact Starter solutions: all components can be easily and rapidly connected to AS-Interface or IO-Link on the basis of the same bit pattern.
How Can You Easily Connect
Industrial Controls and the
Automation Level?
30 www.ued.co.uk
![Page 31: Underwoods](https://reader033.vdocument.in/reader033/viewer/2022042901/568c35ec1a28ab023596148e/html5/thumbnails/31.jpg)
Two system-based standards: AS-Interface …
AS-Interface (AS-i) is a manufacturer-independent bus system, connecting spatially distributed actuators and sensors in the field to the control level, in a particularly easy manner. Every AS-i master is able to control up to 62 field-distributed slaves (e. g. load feeders) per AS-i network. For this purpose, the cost-favorable and rugged system utilizes an unshielded and highly flexible 2-wire cable which allows for the simultaneous transmission of data and power.
... and IO-Link
IO-Link is an intelligent, manufacturer-independent system for the uniform connection of sensors, switching devices and other actuators to the control level – by means of a point-to-point connection beneath the field bus level. The electrical connection is realized via three standard cables. Up to four grouped load feeders (direct-on-line, reversing or star-delta starters in any combination) can be comfortably connected to a port (channel) of the IO-Link master via a standardized IO-Link connection. The IO-Link connection thus concentrates the control and status signals over one cable while also supporting optional transmission of comprehensive diagnostics information from the load feeder.
Simply, with SIRIUS Innovations, via
AS-Interface and IO-Link: Click ’n’ Go!
Thanks to the innovations in the SIRIUS Modular System, complete
load feeders can now be connected to superior controls both via AS-
Interface and IO-Link. This not only ensures maximum flexibility, but
also further minimizes wiring costs in the control circuit and allows for
the transmission of comprehensive diagnostics and status messages
to the automation level. The feeders are actuated directly via the PLC;
SIRIUS thus forms part of Totally Integrated Automation.
OVERVIEW - SIRIUS & IO-Link
31www.ued.co.uk
![Page 32: Underwoods](https://reader033.vdocument.in/reader033/viewer/2022042901/568c35ec1a28ab023596148e/html5/thumbnails/32.jpg)
New SouthgatePurchasing and Logistics CentreUnderwoods Electrical Distributors LtdUnit 6, Brunswick Industrial ParkBrunswick Park RoadNew SouthgateLondon N11 1JL
T: 020 8362 0200
CastlefordUnderwoods Electrical Distributors LtdUnit 5, Sterling Business ParkOff Carr Wood RoadCastlefordWest YorkshireWF10 4PS
T: 01977 667394F: 01977 667395E: [email protected]
EdinburghLucas Power & ControlOffice 52 Bilston Glen Phase 3LoanheadEdinburghEH20 9LZ
T: 0131 448 2828F: 0131 448 2880E: [email protected]
Bury St EdmundsGDR Associates8 Forbes Business CentreKempson WayBury St.EdmundsIP32 7AR
T: 01284-748310F: 01284-748319E: [email protected]
High WycombeUnderwoods Electrical Distributors LtdThe Geans3 Wycombe RoadPrestwoodBucksHP16 0NZ
T: 01494 867890F: 01494 868556E: [email protected]
BristolUnderwoods Electrical Distributors LtdUnit 23, Marsh Lane Industrial EstMarsh Lane, PortburyBristolBS20 0NH
T: 01275 370370F: 01275 370379E: [email protected]
OrpingtonUnderwoods Electrical Distributors LtdUnit 9, Crayfield Ind. ParkMain RoadOrpingtonKentBR5 3HP
T: 01689 897670F: 01689 820721E: [email protected]
NorthamptonUnderwoods Electrical Distributors LtdUnit 14a Bassett CourtLoake CloseNorthamptonNN4 5EZ
T: 01604 764164F: 01604 826884E: [email protected]
SouthamptonUnderwoods Electrical Distributors LtdUnit 5, Hedge End Business Centre30-32 Botley Road, Hedge EndSouthamptonSO30 2AU
T: 01489 799013F: 01489 795347E: [email protected]
Remtech (Repair Centre)43B Leyton AvenueMildenhallSuffolkIP28 7BL
Repairs of PLC, HMI’s and Drives.
T: 01638 714170F: 01638 714162E: [email protected]
www.ued.co.uk