GENERAL REQUIREMENTS

1- THE BUILDING CODE COMPLIANCE INFORMATIONPRESENTED IS TO BE READ IN CONJUNCTION WITH ALLOTHER ARCHITECTURAL AND ENGINEERING DOCUMENTS.

2 - PERFORM ALL WORK IN FULL ACCORDANCE WITH THELATEST EDITION, INCLUDING ALL REVISIONS, OFAPPLICABLE CODES AND REGULATIONS OF FEDERAL,PROVINCIAL, OR LOCAL APPLICATION. IN ANY CASE OFCONFLICT OR DISCREPANCY, THE MORE STRINGENTREQUIREMENTS SHALL APPLY. MEET OR EXCEED THEREQUIREMENTS OF SPECIFIED STANDARDS, CODES ANDREFERENCED DOCUMENTS.

3 - ALL PRODUCTS, MATERIALS, EQUIPMENTINCORPORATED INTO WORK SHALL BE NEW AND OF BESTQUALITY (COMPATIBLE WITH REQUIREMENTS) FORPURPOSES INTENDED. ENSURE QUALITY OF WORK IS OFHIGHEST STANDARD EXECUTED BY WORKERSEXPERIENCED AND SKILLED IN THEIR RESPECTIVETRADE.

4 - OBTAIN AND PAY FOR ALL PERMITS EXCEPT MAINBUILDING PERMIT, AND FEE'S NECESSARY FOR THEEXECUTION OF THE WORK DESCRIBED HEREIN. OBTAINOCCUPANCY PERMIT FROM THE INSPECTION AUTHORITY.

5 - VISIT PROJECT SITE PRIOR TO SUBMITTING BID ANDEXAMINE PLANS, SPECIFICATIONS AND EXISTINGCONDITIONS TO BE MET WITH DURING CONSTRUCTIONOF THE WORK. NO CLAIM WILL BE ACCEPTED FOR EXTRAWORK DUE TO MISUNDERSTANDING OR IGNORANCE OFTHE EXISTING CONDITION OR TERMS AND CONDITIONSOF THE CONTRACT.

6 - SUBMIT SHOP DRAWINGS FOR ITEMS AS NOTED INDOCUMENTS, OR WHERE COMPLEXITY/ COORDINATIONISSUES WARRANT.

7 - WARRANTY ALL WORK AND ITEMS SUPPLIED FOR AMINIMUM PERIOD OF TWELVE (12) MONTHS FROM DATEOF ACCEPTANCE OR UNLESS OTHERWISE NOTED.

FLOOR PLAN DRAWINGS

8 - THESE DRAWINGS ILLUSTRATE ARCHITECTURALREQUIREMENTS INCLUDING: BUILDING ASSEMBLIES,DOORS, WINDOWS, AND RELATED DIMENSIONING DATA;BUILDING MATERIALS AND FINISHES, AND BUILDINGCOMPONENTS. THIS DRAWING IS TO BE READ INCONJUNCTION WITH ALL OTHER DRAWINGS ANDSPECIFICATIONS.

9 - FOR WINDOWS/ GLAZED SCREENS, REFER TO INTERIORELEVATIONS.

10 - ALL CHANGES IN FLOORING FINISHES OR MATERIALSSHALL OCCUR BELOW CENTER LINE OF DOORS UNLESSNOTED OTHERWISE.

11 - ALL CHANGES IN PAINT COLOURS NOTED HEREINSHALL OCCUR AT APPROPRIATE TRANSITION POINTSSUCH AS, CORNERS OF PARTITIONS, REVEAL DETAILS,FLOOR / WALL / CEILING JUNCTIONS OR OTHER CHANGESIN BUILDING LINES, UNLESS OTHERWISE NOTED.

12 - PROVIDE PRE-MANUFACTURED, TRANSITION TRIMSBETWEEN DISSIMILAR MATERIALS TO SUIT THEAPPLICATION OR CONDITION.

13 - REFER TO MECHANICAL / ELECTRICAL DRAWINGS FORSERVICES TO EQUIPMENT AND SPECIALTIES.

14 - THIS DRAWING IS TO BE READ IN CONJUNCTION WITHALL OTHER DRAWINGS.

15 - REFER TO STRUCTURAL DRAWINGS FORHOUSEKEEPING PAD LOCATIONS.

16 - CO-ORDINATE FINAL LOCATION OF FLOOR AND ROOFPENETRATIONS FOR ITEMS SUCH AS FLOOR DRAINS ANDWATER CLOSETS, WITH FLOOR JOIST SHOP DRAWINGS.

SECTIONS AND DETAILS DRAWINGS

16 - THESE DRAWINGS ILLUSTRATE ANY RELATEDENLARGED SECTIONAL DETAILS, INCLUDING BUT NOTLIMITED TO, ROOF ASSEMBLIES, FLOOR ASSEMBLIES,DOOR AND WINDOW TYPICAL ENLARGED DETAILS, WALLSECTIONS, ETC..

17 - THESE DRAWINGS ARE TO BE READ INCONJUNCTION WITH ALL OTHER DRAWINGS.

18 - ELECTRICAL AND MECHANICAL EQUIPMENT AND/ORFIXTURES MAY OR MAY NOT BE SHOWN. REFER TOMECHANICAL AND ELECTRICAL DRAWINGS FOR EXACTSIZE AND LOCATIONS.

19 - ALL EXPOSED STRUCTURAL ELEMENTS ARE TO BESTAINED AND/OR PAINTED. REFER TO PAINTINGSPECIFICATIONS.

GENERAL DRAWINGS NOTES: SYMBOLS LEGEND:BUILDING SECTION BUBBLE, REFER TOREFERENCED DRAWING FOR BUILDINGSECTIONSECTION DETAIL BUBBLE, REFER TOREFERENCED DRAWING FOR SECTIONDETAIL

DOOR NUMBER. REFER TO DOOR SCHEDULE.REFER TO FINISH HARDWARE LIST INSPECIFICATIONS.REFLECTED CEILING PLAN. NOTATION SHOWINGELEVATION AND MATERIAL.

DENOTES WALL TYPE. REFER TO 'TYPICAL WALLASSEMBLY' FOR DETAILS.

ROOM NAME AND NUMBER, REFER TO ROOMFINISH SCHEDULE FOR FINISHES

DENOTES LOCATION OF 1hr FIRE SEPARATION.PROVIDE REQUIRED ULC FIRESTOPPING TOP OFWALL AND FOR INCLUDING BUT NOT LIMITED TOANY PENETRATIONS OF DUCT, PIPING, CONDUIT,WIRING, ETC.

INTERIOR ELEVATION MARKER, REFER TO A6SERIES DRAWINGS FOR ELEVATIONS.

REFERS TO GLAZED SCREEN NUMBERS, REFERTO A5 SERIES DRAWINGS FOR ELEVATIONS.

REFERS TO MILLWORK ELEVATIONS, REFER TOA6 SERIES DRAWINGS FOR ELEVATIONS.

BUILDING CLASSIFICATIONTHE EXISTING BUILDING IS TWO STOREYS (THREE FLOORS, WITH CEILINGOF LOWEST FLOOR LESS 5'-11" ABOVE GRADE IN ACCORDANCE WITHOBC DEFINITIONS). EXISTING BUILDING IS UNSPRINKLERED, FACING TWOSTREETS. BUILDING IS SEPARATED FROM ADJACENT GROUP BOCCUPANCY (JAIL) BY FIREWALL.EXISTING BUILDING AREA= 7,812 sq.ft.EXISTING MAJOR OCCUPANCY OF BUILDING:GROUP D: OFFICESOCCUPANCY AND OCCUPANT LOADS DO NOT CHANGE UNDERRENOVATION BUILDING IS SUBJECT TO OBC PART 33/4 HR FIRE SEPARATION BETWEEN THE EXIT STAIR, ELEVATOR SHAFTAND ELEVATOR MACHINE ROOM AND THE REMAINDER OF THE BUILDINGIN ACCORDANCE WITH SEPARATION REQUIREMENTS OF 3.4.4.1-SEPARATING CONSTRUCTION IS NON-COMBUSTIBLE, AND BUILDING ISLESS THAN 8,610 sq.ft.(TABLE 3.2.2.55)BUILDING MAY BE OF COMBUSTIBLE OR NONCOMBUSTIBLECONSTRUCTION 3.2.2.55.(2). EXISTING BUILDING IS OF COMBUSTIBLE &NONCOMBUSTIBLE CONSTRUCTION. ALL ADJACENT PORTIONS OF THEEXISTING BUILDING ARE NONCOMBUSTIBLE.FIRE SEPARATION WITH NO FIRE RESISTANCE RATING (CONSTRUCTION ISNON-COMBUSTIBLE) IS REQUIRED OF EXISTING FLOOR ASSEMBLIES.

LEGAL LOT DESCRIPTIONPART OF LOT 38, CONCESSION 1, FORMERLY TOWNSHIP OF LOCHIEL,NOW TOWNSHIP OF NORTH GLENGARRY, COUNTY OF GLENGARRY ANDBEING PART 1 ON PLAN 14R-1614.

A.F.F ABOVE FINISHED FLOOROBC ONTARIO BUILDING CODEC/W COMPLETE WITHU/S UNDERSIDEN.T.S NOT TO SCALEACT ACOUSTICAL TILEHM HOLLOW METALPT PAINT FINISHWD WOODBFT BARRIER FREE THRESHOLDWS WEATHER STRIPPINGDS DOOR SWEEPEXT DR EXTERIOR DOORSTAIN STAIN FINISHT&T TEMPERED AND THERMAL GLAZINGWIRED GEORGIAN WIRED GLASSN.I.C. NOT IN CONTRACTDWG DRAWINGGWB GYPSUM WALLBOARDGB GYPSUM BOARDTYP TYPICALRSF RESILIENT SHEET FLOORINGCWT CERAMIC WALL TILERB RUBBER BASESWD SOLID WOOD DOORANOD ANODIZED FINISHTEMP. TEMPERED GLAZINGSD SURFACE MOUNTED SOAP DISPENSERTPD SURFACE MOUNTED TOILET PAPER DISPENSERM1 MIRRORGB1 GRAB BAR 610mmGB2 GRAB BAR 760mm x 760mmPTD PAPER TOWEL DISPENSERND NAPKIN DISPOSALCH COAT HOOKBCS BABY CHANGING STATIONWB WASTE BASKETTEMP. EXISTINGFHC FIRE HOSE CABINETVCT VINYL COMPOSITE TILEMIC MICROWAVEREQ'D REQUIREDTME TO MATCH EXISTINGEQ. EQUALSV SITE VERIFYEX EXISTINGEPY EPOXY PAINT FINISHCPT CARPETTERR TERRAZZOS.S. STAINLESS STEELRBR RUBBER BASECT CERAMIC/PORCELIN TILES CT SEALERRCP REFLECTED CEILING PLANRFS ROOM FINISH SCHEDULET-BAR TEE BAR CEILING SYSTEM

C/W ACOUSTIC LAY-IN CEILING TILESCONC CONCRETEEXP EXPOSED, TO BE PAINTEDBF BARRIER FREE. FABRICATE/INSTALL AS PER OBC

ABBREVIATIONS:

• 5/8" TYPE X GYPSUM BOARD BOTH SIDES OF• 3-5/8" METAL STUDS AT 16" O.C.• INFILL STUD SPACES WITH ACOUSTIC/SOUND

INSULATION (MINERAL WOOL BATT)• PLASTER, PAINT• 6" HIGH RUBBER WALL BASE, BOTH SIDES• WALL TO EXTEND TO U/S OF STRUCTURE.

TYPICAL WALL ASSEMBLY:

DRAWING LIST:ARCHITECTURAL:A0.1 PROJECT TITLEA0.2 GENERAL DRAWING NOTES, SYMBOLS LEGEND, ABBREVIATIONS, OBC

MATRIX & BUILDING CLASSIFICATION, TYP. WALL ASSEMBLY ANDDRAWING LIST.

A1.1 FIRST, SECOND, THIRD & ROOF PLANS - DRAWING DETAIL LOCATIONSA1.2 DOOR SCHEDULE AND SECURITYA1.3 FIRST, SECOND AND THIRD FLOOR PLANS, ROOM FINISH SCHEDULEA3.1 FIRST FLOOR PLAN DEMOLITION AND RENOVATIONSA3.2 SECOND FLOOR PLAN DEMOLITION AND RENOVATIONSA3.3 SECOND FLOOR PLAN DEMOLITION AND RENOVATIONSA3.4 THIRD FLOOR PLAN DEMOLITION AND RENOVATIONSA3.5 THIRD FLOOR REFLECTED CEILING PLANA3.6 ROOF PLANA5.1 EXTERIOR WINDOW REPLACEMENT DETAILSA5.2 LADDER & CAGE DETAILS AND MISC. DETAILSA5.3 EAVESTROUGH & DOWNSPOUTS, ROOF PLAN & ELEVATIONSA6.1 MILLWORK PLANS, SECTIONS, DETAILS AND SPECIFICATIONSA6.2 MILLWORK PLANS, SECTIONS AND DETAILSA6.3 MILLWORK PLANS, SECTIONS & DETAILS AND COLUMN DETAILS

STRUCTURAL:S0.1 GENERAL NOTESS2.1 PART SECOND AND THIRD FLOOR PLANS, SECTIONS AND DETAILS

MECHANICAL:M1.1 PLUMBING SYSTEMS FIRST FLOOR DEMOLITION AND LAYOUTM1.2 PLUMBING AND HVAC SYSTEMS SECOND FLOOR DEMOLITION AND

LAYOUTM1.3 FIRE PROTECTION, PLUMBING AND HVAC SYSTEMS THIRD FLOOR

DEMOLITION AND LAYOUTM1.4 HVAC SYSTEMS ROOF DEMOLITION AND LAYOUTM1.5 SPECIFICATIONS

ELECTRICAL:E1.1 LEGEND, NOTES AND SPECIFICATIONE2.1 OVERALL EXISTING FIRST FLOOR, SECOND FLOOR, THIRD FLOOR &ROOF- ELECTRICAL PANEL LOCATIONSE3.1 PARTIAL FIRST FLOOR - ELECTRICAL DEMOLITION AND NEW LAYOUT.E3.2 PARTIAL SECOND FLOOR - ELECTRICAL DEMOLITION AND NEW LAYOUT.E3.3 PARTIAL SECOND FLOOR - ELECTRICAL DEMOLITION AND NEW LAYOUT.E3.4 PARTIAL THIRD FLOOR - ELECTRICAL DEMOLITION AND NEW LAYOUT.E3.5 ELECTRICAL ROOF PLAN.E4.1 PANEL SCHEDULES

-EXISTING WALL:• CAREFULLY REMOVE ANY EXISTING LOOSE

PLASTER, GYPSUM BOARD, FLAKES, DEBRIS, ETC.,• INFILL WITH NEW PLASTER AND/OR TAPE ANY

HOLES, DENTS, SCRAPES, ETC. TO SURFACE OFEXISTING WALL.

• PREPARE WALL AND WITHIN PERIMETER JAMBS OFWINDOWS AND/OR OTHER ADJACENT SURFACES ORANY OTHER NECESSARY REQUIREMENTS AS PERPAINT MANUFACTURER'S SPECIFICATION PRIOR TOPAINT FINISH.

• PROVIDE FOR PRIME AND PAINT FINISH.• PROVIDE 6" HIGH RUBBER WALL BASE

• 5/8" TYPE X GYPSUM BOARD BOTH SIDES OF• METAL STUDS AT 16" O.C.. WIDTH OF STUD TO MATCH

EXISTING WALL UPON COMPLETION. (I.E. EXISTINGGYPSUM BOARD ON EITHER SIDE OF WALL TO MATCHNEW GYPSUM BOARD)

• INFILL STUD SPACES WITH ACOUSTIC/SOUNDINSULATION (MINERAL WOOL BATT)

• PLASTER, PAINT• 6" HIGH RUBBER WALL BASE, BOTH SIDES• WALL TO EXTEND TO U/S OF STRUCTURE.

DENOTES TYPICAL 'DEMOLITION' NOTATION.REFER TO 'DEMOLITION NOTES FORCORRESPONDING NUMBER ON PLANS.DENOTES TYPICAL 'RENOVATION' NOTATION.REFER TO 'RENOVATION' NOTES FORCORRESPONDING NUMBER ON PLANS.

DENOTES NEW WINDOW NUMBERW2

CEILING HEIGHTCEILING FINISH

GENERAL NOTES:1. ALL WORK TO COMPLY WITH THE LATEST ONTARIO BUILDING

CODE, ONTARIO CONSTRUCTION SAFETY ACT, LOCAL CODESAND BYLAWS, AND OTHER APPLICABLE REQUIREMENTS.

2. DO NOT SCALE DRAWINGS.3. VERIFY ALL LINES, LEVELS, AND CENTERS ON SITE, PRIOR TO

PROCEEDING WITH THE WORK. ENSURE THAT ALLDIMENSIONS AGREE WITH THE DRAWINGS AND THEIRCORRECT INTERRELATION. FAILURE TO SITE VERIFY IS THERESPONSIBILITY OF THE CONTRACTOR FOR ANY NEWMATERIALS AND/OR RE-INSTALLATION/RELOCATION OFEXISTING MATERIALS THAT DOES NOT FIT AND/OR CANNOTBE INSTALLED AND SHALL BE AT NO COST TO THE OWNERFOR REPLACEMENT AND/OR NEW. REPORT ANYDISCREPANCIES TO THE CONSULTANT.

4. ALL NEW GYPSUM BOARD TO BE 16mm FIBEROCK ABUSERESISTANT TYPE 'X' FIRE CODE GYPSUM BOARD (UNLESSOTHERWISE NOTED) BY CGC OR APPROVED ALTERNATE ANDTO BE INSTALLED AS PER MANUFACTURER'S WRITTENSPECIFICATIONS. ANY GYPSUM BOARD USED ABOVEFINISHED CEILING LINE TO BE 16mm TYPE 'X' GYPSUM BOARD.

5. PROVIDE TYPICAL BLOCKING IN STUD SPACE AS REQUIREDFOR INSTALLATION OF, INCLUDING BUT NOT LIMITED TO:SINKS, MILLWORK, EQUIPMENT, WASHROOM ACCESSORIES,ETC.

6. MAKE GOOD FLOOR, WALL, AND CEILING SURFACES ASREQUIRED WHERE DEMOLITION OF EXISTING MATERIALS ANDCOMPONENTS AFFECTS INSTALLATION OF NEWCONSTRUCTION AND FINISHES.

7. FOR DOORS AND DOOR FRAMES AS DENOTED TO BEPAINTED, PREPARE SURFACES ON BOTH SIDES READY TORECEIVE NEW PAINT FINISH. REFER TO PAINTINGSPECIFICATION FOR ADDITIONAL INFORMATION AND TYPE OFPAINT APPLIED TO METAL OR WOOD DOORS AND METALFRAMES.

8. REFER TO STRUCTURAL, ELECTRICAL AND MECHANICALDRAWINGS AND SPECIFICATIONS FOR EXTENT OF WORK.

9. ON DRAWINGS DENOTED FOR AREAS TO BE PAINTED, ALLSURFACES SHALL BE READY TO RECEIVE PRIME PAINT FINISHAS PER PAINT MANUFACTURER'S WRITTEN SPECIFICATIONS,INCLUDING BUT NOT LIMITED TO; INFILLING OFINDENTATIONS, CRACKS, HOLES, CLEANING WALLSSURFACES, REMOVING FLAKING PLASTER AS REQUIRED,REMOVAL OF ANY ADHESIVES, ETC. UPON PREPARATION OFEXISTING SURFACES, APPLY PRIME PAINT COAT FINISHFOLLOWED BY TWO PAINT FINISH COATS. REFER TOPAINTING SPECIFICATIONS FOR ADDITIONAL COATS OF PAINTIF REQUIRED AND INFORMATION AND TYPE OF PAINTAPPLIED TO SPECIFIC EXISTING SURFACES.

10. IN ROOMS OR AREAS REQUIRED TO BE RENOVATED, REMOVEALL DRYWALL PLUGS AND PATCH AS REQUIRED.

11. PRIOR TO PAINT FINISH, NEATLY MASK/TAPE INCLUDING BUTNOT LIMITED TO ALL; EXISTING AND/OR NEW DOOR STOPS,EXPANSION JOINT COVERS, EXISTING WIREMOLD, FIREALARM DEVICES, AND THERMOSTATS, ETC., ALSO, IN ROOMSREQUIRED TO BE PAINTED INFILL ANY HOLES PRIOR TO PAINTFINISH. REMOVE ANY PAINT SPOTS AND/OR DRIPS PRIOR TOPAINTING.

12. REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOREXISTING FLOORING TO REMAIN AND/OR TO PROVIDE NEWFLOORING.

13. IN ROOMS OR AREAS THAT ARE REQUIRED TO BERENOVATED, REMOVE ALL MISCELLANEOUS WOOD AND/ORMETAL BLOCKING(S) SURFACE MOUNTED TO WALLS ANDPREPARE WALL SURFACES UPON REMOVAL READY TORECEIVE PAINT FINISH AS PER PAINT MANUFACTURER'SWRITTEN SPECIFICATIONS.

14. FOR ANY WALL BASE THAT IS MISSING WITHIN ROOMS THATARE TO BE RENOVATED, PROVIDE 6" HIGH BLACK RUBBERWALL BASE UNLESS OTHER PRODUCT IS NOTED OTHERWISE.

15. PRIOR TO PAINT FINISH, NEATLY TEMPORARY MASK/TAPEINCLUDING BUT NOT LIMITED TO ALL; EXISTING DOOR STOPS,EXISTING FIRE ALARM DEVICES, THERMOSTATS, ETC.CAREFULLY REMOVE EQUIPMENT/FIXTURES THAT CANEASILY BE REMOVED SUCH AS CLOCKS, COVERPLATES/SWITCHES ETC AND TAG & STORE TO BE INSTALLEDWHEN PAINTING IS COMPLETED. CONFIRM WITH OWNERPRIOR TO PAINT FINISH WHAT EQUIPMENT/FIXTURES WITHINROOM IS TO BE REMOVED AND TAGGED OR CAN BETEMPORARILY MASKED OR TAPED.

16. COORDINATE FOR ANY PENETRATIONS FOR CONDUIT/WIRINGFOR "WIREMOLD" WITH ELECTRICAL. CONFIRM WITHELECTRICAL EXACT SIZE AND LOCATIONS PRIOR TOSAWCUTTING AND/OR COREDRILLING. REFER TO GENERALDEMOLITION NOTES.

17. ENSURE ALL SHOP DRAWINGS PROVIDED ARE AS PER SITECONDITIONS PRIOR TO ANY FABRICATIONS AND/ORINSTALLATION

1. UNLESS NOTED OTHERWISE, ALL REMOVED AND DEMOLITIONMATERIALS ARE TO BE REMOVED FROM SITE AND DISPOSED OF IN ALEGAL MANNER. (I.E "REMOVE" IS TO BE REMOVED FROM SITE ANDDISPOSED). COORDINATE WITH OWNER EXACT LOCATIONS ANDSTORAGE OF RE-USED EQUIPMENT AND/OR MATERIALS, PRIOR TOPLACEMENT.

2. WHERE EXISTING GROUNDS AND BUILDINGS ARE AFFECTED BY WORKOF CONTRACT (INCLUDING, BUT NOT LIMITED TO SUPPLY AND REMOVALOF DUMPSTERS, VEHICULAR TRAFFIC, ETC.), FOR EXISTING GRASSEDAREAS, REINSTATE c/w 4" TOPSOIL AND SOD. FOR EXISTINGASPHALTED/PAVED AREAS, REINSTATE WITH HL3 (40mm) ON HL8 (50mm)ON 150mm GRANULAR 'A' COMPACTED TO 100% SPDD ON MIN. 600mm(OR TO TOP OF EXISTING GRANULAR) GRANULAR 'B' COMPACTED TO100% SPDD. ALSO, CLEAN AND REINSTATE ALL EXISTING SURFACES OFBUILDING TO MATCH EXISTING.

3. ALL SALVAGEABLE MATERIALS AND/OR EQUIPMENT, FURNISHINGS, ETCFROM DEMOLITION OPERATIONS TO REMAIN PROPERTY OF OWNER.COORDINATE WITH OWNER ITEMS TO BE REMOVED OFF SITE AND ITEMSTO BE RE-USED, RECYCLED, RELOCATED AND WHERE THEY ARE TO BETEMPORARILY STORED. (REFER TO NOTE NO.2)

4. REFER TO DRAWINGS FOR LOCATIONS OF THE REMOVAL OFPARTITIONS, DOORS, FRAMES, FURRED OUT SPACES AND OTHER ITEMSSHOWN DASHED. WHERE PORTIONS OF WALLS OR OTHER SURFACESARE REQUIRED TO REMAIN, NEATLY SAWCUT ALONG LINE OFDEMOLITION TO PROVIDE CLEAN, STRAIGHT AND PLUMB EDGE OFEXISTING WALL TO REMAIN. PROVIDE SUPPORTING BLOCKING ORFRAMING AT CUT EDGES AS REQUIRED.

5. REFER TO DRAWINGS FOR REMOVAL OF FLOORING AS REQUIRED.GRIND OFF BUMPS AND REMOVE ADHESIVE BY CHEMICAL ORMECHANICAL MEANS. REMOVE WALL BASE AS REQUIRED AND PREPAREWALL SURFACES READY TO RECEIVE NEW WALL BASE. IN AREASWHERE NEW FLOOR FINISHES ARE REQUIRED, MAKE FLOORS READYFOR APPLICATION AS PER MANUFACTURERS PRINTED SPECIFICATIONS.

6. WHERE REQUIRED FOR ACCESS OF ELECTRICAL TRADES, SAWCUTEXISTING FINISHES WHICH ARE OTHERWISE CALLED TO REMAIN, ANDREMOVE MATERIAL AS REQUIRED FOR ACCESS OF THESE TRADES.REVIEW ELECTRICAL DOCUMENTS TO ASCERTAIN LOCATIONS.

7. WHERE EXISTING PIPES, CONDUITS, DUCTWORK, ETC. PASS THROUGHFIRE SEPARATIONS OR WHERE EXISTING PIPES, CONDUITS, DUCTS AREREMOVED OR ALTERED, PROVIDE FIRESTOPPING AS REQUIRED INSPACES AND OPENINGS TO MAINTAIN REQUIRED FIRE SEPARATION.

8. WHERE SMOKE DETECTORS, HEAT DETECTORS AND OTHER FIREALARM COMPONENTS ARE TO REMAIN, CONTRACTOR TO MAKEPROVISIONS TO ENSURE ALL COMPONENTS ARE PROTECTED FROMDAMAGE THAT MAY OCCUR DURING THE CONSTRUCTION (I.E. DUSTCONTROL, ETC.)

9. FOR ANY EXISTING LIGHT FIXTURES (INCLUDING HOUSING, BALLAST,TUBES) THAT ARE INDICATED TO BE REMOVED, HAND OVER TO OWNER.COORDINATE WITH OWNER REQUIREMENTS FOR PROPER HANDLINGPROCEDURES OF ALL MATERIALS FOR STORAGE AND/OR REMOVALPURPOSES.

10. DEMOLITION TYPES AND EXISTING CONDITIONS INDICATED ON THEDRAWINGS ARE APPROXIMATE ONLY, INTENDED AS A GENERALINDICATION OF SITE CONDITIONS. SITE VERIFY AND ASSUMERESPONSIBILITY FOR ALL EXISTING CONDITIONS PRIOR TO STARTINGWORK.

11. REFER TO ELECTRICAL DRAWINGS FOR SAWCUTTING OF NEWRECEPTACLES AND/OR CONDUIT/WIRING. COORDINATE WITHELECTRICAL EXACT LOCATIONS AND SIZES OF SAWCUTS PRIOR TOSTARTING OF WORK OR DEMOLITION. REFER TO SPECIFICATIONS ANDNOTE NO.17 FOR NOISY WORK.

12. REMOVE ALL DRYWALL PLASTIC PLUGS AND PATCH AND REPAIR PRIORTO PAINT FINISH IN ROOMS THAT ARE REQUIRED TO BE RENOVATED.

13. REPLACE ANY DAMAGED CEILING TILE FOR ANY ITEMS THAT AREDENOTED TO BE REMOVED THAT PENETRATE AND/OR AREADJACENT/ABUT EXISTING CEILING TILE.

14. OWNER TO REMOVE ALL POSTERS, SIGNAGE, PLAQUES, GRAPHICS,ETC. FROM WALLS PRIOR TO PAINT FINISH.

15. NEATLY COREDRILL AND/OR SAWCUT FOR ANY NEW ELECTRICALCONDUIT/WIRING. UPON INSTALLATION OF ELECTRICAL, PROVIDE FORFIRESTOPPING AS REQUIRED. PRIOR TO COREDRILLING/SAWCUTTING,COORDINATE WITH ELECTRICAL EXACT SIZE AND LOCATION OFPENETRATIONS REQUIRED.

16. CUT, PATCH AND MAKE GOOD TO MATCH EXISTING WHERE NEW WORKCONNECTS WITH EXISTING AND WHERE EXISTING WORK IS ALTERED.

17. COORDINATE WITH OWNER'S REPRESENTATIVE TO SCHEDULE ANYWORK WHICH MIGHT DISTURB OCCUPANTS OR AFFECT REGULAROPERATIONS OF THE BUILDING/OFFICES TO TIMES OUTSIDE OFREGULAR HOURS AS REQUIRED TO PREVENT DISRUPTION. ASSUMEFULL RESPONSIBILITY FOR THE PROTECTION OF EXISTING EQUIPMENT,MATERIALS AND ASSEMBLIES FROM DAMAGE DUE TO CONSTRUCTIONAND/OR DEMOLITION. TRANSPORT CONSTRUCTION AND DEMOLISHEDMATERIALS TO AND FROM SITE IN MANNER COORDINATED WITHOWNER'S REPRESENTATIVE AND AS REQUIRED TO PREVENT ANYDISRUPTION TO THE REGULAR OPERATIONS OF THE BUILDING/OFFICES.

18. ASSEMBLIES, DIMENSIONS, AND THE NUMBER AND KIND OF EXISTINGCONDITIONS INDICATED ON THE DRAWINGS ARE APPROXIMATE ONLY,AND ARE INTENDED AS A GENERAL INDICATION OF SITE CONDITIONS.SITE VERIFY AND ASSUME RESPONSIBILITY FOR ALL EXISTINGCONDITIONS PRIOR TO STARTING WORK. REPORT DISCREPANCIES INDETAILED WRITING TO THE CONSULTANT. APPROACH ANY SUCHDISCREPANCIES BETWEEN EXISTING CONDITIONS AND THE CONTRACTDOCUMENTS AS INDICATED IN THE CONTRACT DOCUMENTS FORSIMILAR CONDITIONS ELSEWHERE AT NO ADDITIONAL COST.

19. REFER TO STRUCTURAL, MECHANICAL AND ELECTRICAL DOCUMENTSFOR THE EXTENT OF DEMOLITION WORK AND COORDINATE ASREQUIRED.

20. ACCESS IS RESTRICTED ON SITE TO THE PLACE OF WORK. RESTRICTPARKING AND LOCATION OF DUMPSTERS AND TEMPORARY FACILITIESON SITE AS DIRECTED BY OWNER'S REPRESENTATIVE.

21. FOR DENOTED DOORS AND DOOR FRAMES, PREPARE SURFACES ONBOTH SIDES READY TO RECEIVE NEW PAINT FINISH. REFER TO PAINTINGSPECIFICATION FOR ADDITIONAL INFORMATION AND TYPE OF PAINTAPPLIED TO METAL OR WOOD DOORS AND METAL FRAMES.

22. REMOVE ALL DRYWALL PLUGS AND PATCH AS REQUIRED.23. CAREFULLY REMOVE EXISTING WALL MOUNTED MATERIAL/EQUIPMENT

c/w ALL ASSOCIATED FASTENERS, BRACKETS, ETC.. PREPARE WALLSURFACES READY TO RECEIVE PAINT FINISH AS PER PAINTMANUFACTURER'S WRITTEN SPECIFICATIONS.

24. ALL CLOCKS, PHONES, FIRE ALARM, ANY FIXED COVERS FOR ANYFIXTURES USED THAT IS TO REMAIN FOR THE DAILY FUNCTIONING OFTHE OFFICES/BUILDING ARE TO BE CAREFULLY PROTECTED DURINGCONSTRUCTION. UPON COMPLETION OF THE WORK IN THE ROOM,UNCOVER PROTECTIVE WRAP AND ENSURE THESE FIXTURES AREFUNCTIONAL. IF ANY OF THESE DEVICES AND/OR FIXTURES AREDAMAGED AND/OR LOST, PROVIDE THE SAME TO MATCH EXISTING ATNO COST TO THE OWNER.

25. REMOVE ALL MISCELLANEOUS WOOD AND/OR METAL BLOCKING(S)SURFACE MOUNTED TO WALLS AND PREPARE WALL SURFACES UPONREMOVAL READY TO RECEIVE PAINT FINISH AS PER PAINTMANUFACTURER'S WRITTEN SPECIFICATIONS.

26. REMOVE EXISTING BLINDS c/w TRACKS. TAG, PROTECT AND STORE FORRE-INSTALLATION UNLESS DENOTED OTHERWISE. PRIOR TO REMOVAL,CONFIRM WITH OWNER.

27. REFER TO HAZARDOUS MATERIALS ASSESSMENT REPORTS PRIOR TOANY DEMOLITION.

GENERAL DEMOLITION NOTES:

INTERIOR SHAFT WALL• 5/8" GYPSUM BOARD ABUSE TYPE 'X'• 2 1/2" C-H STUDS• 1" TYPE 'X' GYPSUM BOARD• ULC DESIGN NO. W452 (1HR FRR)

M:\20

15\15

9-00

336-

00 S

DG 2n

d Ren

os\dw

g\ARC

H\15

9-00

336-

00-A

LL S

eries

-July

12-2

016.d

wg J

ul 12

, 201

6-4:3

0pm

BY:(a

ndre

w.bo

uwma

n)M:

\2015

\159-

0033

6-00

SDG

2nd R

enos

\dwg\A

RCH\

159-

0033

6-00

-ALL

Ser

ies-J

uly 12

-201

6.dwg

Jul

12, 2

016-

4:30p

m BY

:(and

rew.

bouw

man)

C F

C

C F

C

A

E

F

C

D

B

1235 4678910

1235 4678910

A

E

F

C

D

B

FFF

P

FFF

F

F

SEAL:

CONSULTANT - SUB CONSULTANT:

CLIENT:

PROJECT:

CLIENT REF. #:

DISCLAIMER: COPYRIGHT:

ISSUED FOR - REVISION:

DESCRIPTIONDATEREIS

KEY PLAN:

ISSUE:

DATE OF:

ORIGINAL SCALE:

CHECKED BY:

DRAWN BY:

SHEET #: OF

TITLE:

DISCIPLINE:

1"

IF THIS BAR IS NOT 1"LONG, ADJUST YOUR

PLOTTING SCALE.

PROJECT NO: DATE:

SHEET NUMBER:

DESIGNED BY:

THIS DRAWING AND DESIGN IS COPYRIGHT PROTECTED WHICH SHALL NOT BE USED, REPRODUCED ORREVISED WITHOUT WRITTEN PERMISSION BY WSP. THE CONTRACTOR SHALL CHECK AND VERIFY ALLDIMENSIONS AND UTILITY LOCATIONS AND REPORT ALL ERRORS AND OMISSIONS PRIOR TOCOMMENCING WORK.THIS DRAWING IS NOT TO BE SCALED.

F

F

REV #

1345 ROSEMOUNT AVENUECORNWALL, ONTARIO, CANADA K6J 3E5

TEL: 613-933-5602 | FAX: 613-936-0335 | ARCHITECTURE49.COM

UNITED COUNTIES OF STORMONT,DUNDAS AND GLENGARRY

BUILDING RENOVATIONS

--

159-00336-00 JULY 2016

ISSUED FOR TENDERJULY 12, 2016

0

1 2016/07/12 ISSUED FOR TENDER

1345 ROSEMOUNT AVENUECORNWALL, ONTARIO

CANADA K6J 3E5PHONE: 613-933-5602 FAX: 613-936-0335

WWW.WSPGROUP.COM

AS SHOWN

RT

AB

BW

ARCHITECTURAL

GENERAL DRAWING NOTES,SYMBOLS LEGEND, ABBREVIATIONS,

OBC MATRIX & BUILDINGCLASSIFICATION, TYP. WALL

ASSEMBLY AND DRAWING LIST

A0.2-- --