universal carrier 12 ga hanger wire, by others, not by

11
1 1 4 " 1 25 32 " 17 32 " DETAIL 'A' SCALE: 3" = 1'-0" UNIVERSAL CARRIER EXTERIOR INSTALLATION 6" 5 5 32 " 27 32 " 1" WALL ANGLE SEE DETAIL B1.6 SEE DETAILS B1.8 THROUGH B1.9 FOR FIXTURE OPENING RECOMMENDATIONS 6" MODULE UNIVERSAL CARRIER SPLICE SEE DETAIL B1.5 FLAT RECESSED CLOSURE, REQUIRED FOR EXTERIOR INSTALLATION TYPICAL SYSTEM SECTION SEE DETAIL 'A' THIS SHEET BOX 6 PANEL SEE DETAIL B1.1 PANEL SPAN VARIES DEPENDING ON DESIGN WIND PRESSURE SEE DETAIL B1.2 PANEL LENGTH 3'-0" MIN - 16'-0" MAX (RECOMMENDED) CARRIER SPAN VARIES DEPENDING ON DESIGN WIND PRESSURE SEE DETAIL B1.2 CARRIER OVERHANG 6" MAX PANEL OVERHANG 6" MAX 6" MAX CARRIER OVERHANG @ SPLICE 12 GA HANGER WIRE WITHIN 3" OF VERTICAL SUPPORT FLOATING TRIM SEE DETAIL B1.7 TRIM NOT SHOWN FOR CLARITY SUSPENSION REQUIREMENTS SEE DETAIL B1.2 PANEL SPLICE SEE DETAIL B1.4 12 GA HANGER WIRE, BY OTHERS, NOT BY CERTAINTEED SEE DETAIL B1.2 VERTICAL SUPPORT SEE DETAIL B1.3 5015 Oakbrook Parkway, Suite 100 Norcross, GA 30093 O 800 366 4327 F 770 806 0214 www.certainteed.com/architectural SPECIFICATIONS (unless noted otherwise) MATERIAL: .020" | .025" | .032" | .040" ALUMINUM BOX 6 PANEL | .040" ALUMINUM UNIVERSAL CARRIER FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LUXACOTE PERFORATION: NON-PERFORATED | #160 OVERALL ISOMETRIC VIEW PROJECT: EXTERIOR BOX 6 PRODUCT SPECIFICATIONS DRAWING NUMBER: EXT-BOX6-B1.0 SCALE: AS SHOWN DRAWN BY: CTA ENGINEERING DATE: 6/1/21 These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

Upload: others

Post on 28-Mar-2022

0 views

Category:

Documents


0 download

TRANSCRIPT

UNIVERSAL CARRIER
EXTERIOR INSTALLATION
SEE DETAILS B1.8 THROUGH B1.9 FOR FIXTURE OPENING RECOMMENDATIONS
6" MODULE UNIVERSAL CARRIER SPLICE SEE DETAIL B1.5
FLAT RECESSED CLOSURE, REQUIRED FOR EXTERIOR INSTALLATION
TYPICAL SYSTEM SECTION SEE DETAIL 'A' THIS SHEET
BOX 6 PANEL SEE DETAIL B1.1
PANEL SPAN VARIES DEPENDING
ON DESIGN WIND PRESSURE
CARRIER SPAN VARIES DEPENDING
ON DESIGN WIND PRESSURE
3" OF VERTICAL SUPPORT
FLOATING TRIM SEE DETAIL B1.7 TRIM NOT SHOWN FOR CLARITY
SUSPENSION REQUIREMENTS SEE DETAIL B1.2
PANEL SPLICE SEE DETAIL B1.4
12 GA HANGER WIRE, BY OTHERS, NOT BY CERTAINTEED SEE DETAIL B1.2
VERTICAL SUPPORT SEE DETAIL B1.3
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
MATERIAL: .020" | .025" | .032" | .040" ALUMINUM BOX 6 PANEL | .040"
ALUMINUM UNIVERSAL CARRIER
PERFORATION: NON-PERFORATED | #160
OVERALL ISOMETRIC VIEW
DRAWING NUMBER: EXT-BOX6-B1.0
SCALE: AS SHOWN
These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an
architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable
for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the
fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure
compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.
13 16" FLAT RECESSED
125 32 " S
LONGER LENGTH PANELS AVAILABLE, CONTACT CERTAINTEED
*PANEL LENGTHS AVAILABLE IN ± 18" TOLERANCE, MINIMUM QUANTITIES MAY APPLY
UNIVERSAL CARRIER BOX 6 PANEL 17 32 " P
AN EL
H EI
GH T
MATERIAL THICKNESS
PANEL FINISHES
LUXACOTE - INTERIOR & EXTERIOR
5 5 32" PANEL WIDTH
17 32 " P
AVAILABLE PERFORATIONS SCALE: FULL (1:1)
PERFORATION #160: PERF. AREA 23% OPEN
HOLE DIAMETER 0.060"
Norcross, GA 30093
MATERIAL: .020" | .025" | .032" | .040" ALUMINUM BOX 6 PANEL | .040"
ALUMINUM UNIVERSAL CARRIER
PERFORATION: NON-PERFORATED | #160
DRAWING NUMBER: EXT-BOX6-B1.1
SCALE: AS SHOWN
These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an
architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable
for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the
fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure
compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.
FLAT RECESSED CLOSURE REQUIRED FOR EXTERIOR INSTALLATION
BOX 6 PANEL, .025", .032", OR .040" ALUMINUM REQUIRED FOR EXTERIOR
UNIVERSAL CARRIER, .040" ALUMINUM
VERTICAL SUPPORT 1/2" X 1-1/2" 16 GA GALV. CRC , MAX LENGTH 28", SEE NOTE 3 DRAWING # EXT-BOX6-B1.3 FOR VERTICAL SUPPORT REQUIREMENTS AND EQUALS
DESIGN WIND PRESSURE (POSITIVE OR NEGATIVE PSF**) (PANEL SPAN)
CARRIER SPACING * CARRIER SPAN (VERTICAL SUPPORT SPACING)
** POUNDS PER SQUARE FOOT
* NOTE: CARRIER SPACING BASED ON USING 3 OR MORE CARRIERS
20
25
30
35
40
TABLE 1 - DESIGN WIND LOAD - LINEAR BOX EXTERIOR CEILING SYSTEM
PANEL TYPE: .025", .032", OR .040" ALUMINUM, BOX 6 PANEL CARRIER TYPE: .040" ALUMINUM, UNIVERSAL CARRIER
ALLOWABLE CARRIER SPACING (PANEL SPAN) ALLOWABLE CARRIER SUPPORT SPACING (HANGER WIRE/VERTICAL SUPPORT SPACING)
45 1'-10" 1'-9"
O.C. CARRIER SPACING
O.C. CARRIER SPAN
6" MAX PANEL
3" OF VERTICAL SUPPORT
O.C. CARRIER SPACING
O.C. CARRIER SPAN
EXTERIOR INSTALLATION
NOTE A:
CARRIER SPACING (PANEL SPAN) AND CARRIER SPAN (HANGER WIRE & VERTICAL SUPPORT SPACING) VARIES DEPENDING ON DESIGN WIND PRESSURE (POUNDS PER SQUARE FOOT). AS A GENERAL GUIDE, REFER TO THE DETAIL AND WIND LOAD TABLE 1 BELOW FOR CARRIER SPACING AND CARRIER SPAN. THE WIND LOAD CRITERIA IS BASED ON USING 3 OR MORE ROWS OF CARRIER. MAXIMUM PANEL OVERHANG = 6". MAXIMUM CARRIER OVERHANG = 6".
HANGER WIRE (12 GA MIN.) MUST BE LOCATED AT EACH VERTICAL SUPPORT STRUT. VERTICAL SUPPORT STRUT MUST NOT EXCEED SPACING SHOWN FOR A GIVEN DESIGN WIND PRESSURE. SEE DRAWING # EXT-BOX6-B1.3 FOR VERTICAL SUPPORT SPECIFICATION. HANGER WIRE AND VERTICAL SUPPORT STRUT MUST BE ATTACHED TO STRUCTURE ABOVE TO SAFELY SUPPORT ALL LOADS IMPOSED BY SOFFIT SYSTEM. ATTACHMENT TO STRUCTURE DESIGNED AND PROVIDED BY OTHERS, NOT BY CERTAINTEED.
NOTE B: ALL PENETRATIONS IN CEILING TO BE FIELD LOCATED AND FIELD CUT. TRIM FOR THESE ITEMS NOT BY CERTAINTEED.
NOTE C: ATTACHMENT TO STRUCTURE DESIGNED AND PROVIDED BY OTHERS, NOT BY CERTAINTEED.
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
MATERIAL: .020" | .025" | .032" | .040" ALUMINUM BOX 6 PANEL | .040"
ALUMINUM UNIVERSAL CARRIER
PERFORATION: NON-PERFORATED | #160
EXTERIOR SUSPENSION SPECIFICATIONS
DRAWING NUMBER: EXT-BOX6-B1.2
SCALE: AS SHOWN
These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an
architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable
for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the
fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure
compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.
FLAT RECESSED CLOSURE REQUIRED FOR EXTERNAL INSTALLATION
125 32 "
OR
(2) NO. 10 TEK SCREWS, NOT BY CERTAINTEED
1/4" DIAMETER X 20 GRADE 2 NUT & BOLT IN PRE- PUNCHED CARRIER HOLE, NOT BY CERTAINTEED
OR
NOTE A:
VERTICAL SUPPORT STRUTS (MINIMUM 1-1/2" 16 GA GALV. 'C' CHANNEL OR EQUAL, MAX LENGTH OF 28"). SEE DRAWING # EXT-BOX6-B1.2 FOR EXTERIOR SUSPENSION REQUIREMENTS. VERTICAL SUPPORTS SHALL BE LOCATED WITHIN 6" OF THE ENDS OF EACH CARRIER AND WITHIN 6" ON BOTH SIDES OF A CARRIER SPLICE.
VERTICAL SUPPORT EQUALS:
DIETRICH STE-20 2-1/2" 20 GA GALV. MAX LENGTH OF 85"
DIETRICH TRNB-25 MAX LENGTH OF 78"
*** ATTACHMENT TO STRUCTURE ABOVE SHALL BE DESIGNED AND PROVIDED BY OTHERS TO SUPPORT ALL LOADS IMPOSED BY CEILING SOFFIT SYSTEM ***
NOTE C: ATTACHMENT TO STRUCTURE DESIGNED AND PROVIDED BY OTHERS, NOT BY CERTAINTEED.
NOTE B: ALL PENETRATIONS IN CEILING TO BE FIELD LOCATED AND FIELD CUT. TRIM FOR THESE ITEMS NOT BY CERTAINTEED.
BOX 6 PANEL, .025", .032", OR .040" ALUMINUM REQUIRED FOR EXTERIOR
'A'
'A'
BOX 6 PANEL
12 GA HANGER WIRE, WITHIN 3" OF VERTICAL SUPPORT, NOT BY CERTAINTEED
SECTION 'A' SCALE: 3" = 1'-0"
12 GA (.109") MIN X 3/4" WIDTH MIN
1/2" MAX
1" MIN
EXTERIOR INSTALLATION
SPACING REQUIREMENTS
(2) NO. 10 TEK SCREWS, NOT BY CERTAINTEED
VERTICAL SUPPORT DIETRICH STE-20 2-1/2" 20 GA GALV. STEEL STUD OR EQUAL, MAX LENGTH 85", SEE NOTE A THIS SHEET FOR VERTICAL SUPPORT REQUIREMENTS
VERTICAL SUPPORT 1/2" X 1-1/2" 16 GA GALV. CRC, MAX LENGTH 28", SEE NOTE A THIS SHEET FOR VERTICAL SUPPORT REQUIREMENTS
1/2" X 1-1/2" 16 GA GALV. CRC SECURED TO CARRIER WITH 12 GA GALV. BRACKET, NOT BY CERTAINTEED
1/2" X 1-1/2" 16 GA GALV. CRC
DIETRICH STE-20 2-1/2" 20 GA GALV. STEEL STUD
OR
OR
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
MATERIAL: .020" | .025" | .032" | .040" ALUMINUM BOX 6 PANEL | .040"
ALUMINUM UNIVERSAL CARRIER
PERFORATION: NON-PERFORATED | #160
DRAWING NUMBER: EXT-BOX6-B1.3
SCALE: AS SHOWN
These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an
architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable
for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the
fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure
compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.
EXTERIOR INSTALLATION *VERTICAL SUPPORTS AND HANGER WIRE OMITTED FOR CLARITY
NOTE 1: DO NOT SPLICE PANELS DIRECTLY BELOW UNIVERSAL CARRIERS. PANEL SPLICES DO NOT FIT UNDER CARRIERS.
NOTE 2: FIELD CUT PANELS AS REQUIRED TO CREATE A RANDOM STAGGERED SEAM PATTERN. AVOID ALIGNED SEAMS.
SECTION 'A' SCALE: 3" = 1'-0"
SECTION 'B' SCALE: 3" = 1'-0"
PANEL SEAM
BOX 6 PANEL SPLICE, WILL NOT FIT UNDER UNIVERSAL CARRIER
BOX 6 PANEL
BOX 6 PANEL SPLICE, WILL NOT FIT UNDER UNIVERSAL CARRIER
UNIVERSAL CARRIER BEYOND
BOX 6 PANEL
Norcross, GA 30093
MATERIAL: .020" | .025" | .032" | .040" ALUMINUM BOX 6 PANEL | .040"
ALUMINUM UNIVERSAL CARRIER
PERFORATION: NON-PERFORATED | #160
DRAWING NUMBER: EXT-BOX6-B1.4
SCALE: AS SHOWN
These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an
architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable
for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the
fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure
compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.
EXTERIOR INSTALLATION
SECTION 'B' SCALE: FULL (1:1)
IF THE DESIRED CARRIER LENGTH EXCEEDS THE MAXIMUM OF 16'-0", USE A UNIVERSAL CARRIER SPLICE TO CONNECT THE FACTORY CARRIER ENDS.
THE TABS OF THE SPLICE SNAP INTO THE HOLES IN THE CARRIER AND ADDITIONAL FIXING IS NOT NECESSARY. THE MODULE IS CONTINUED AUTOMATICALLY.
SNAP SPLICE TABS INTO UNIVERSAL CARRIER
UNIVERSAL CARRIER
UNIVERSAL CARRIER SPLICE
VERTICAL SUPPORT 1/2" X 1-1/2" 16 GA GALV. CRC OR EQUAL, MAX LENGTH 28", SEE NOTE A ON DRAWING # EXT-BOX6-B1.3 FOR VERTICAL SUPPORT REQUIREMENTS
6" MAX AT CARRIER SPLICE, TYPICAL
SEE TABLE 1 ON DRAWING # EXT-BOX6-B1.2 FOR MAX O.C.
SPACING REQUIREMENTS, TYPICAL
12 GA HANGER WIRE, WITHIN 3" OF VERTICAL SUPPORT, TYPICAL, NOT BY CERTAINTEED
12 GA HANGER WIRE, WITHIN 3" OF VERTICAL SUPPORT, TYPICAL, NOT BY CERTAINTEED
UNIVERSAL CARRIER SPLICE
6" MAX AT
Norcross, GA 30093
MATERIAL: .020" | .025" | .032" | .040" ALUMINUM BOX 6 PANEL | .040"
ALUMINUM UNIVERSAL CARRIER
PERFORATION: NON-PERFORATED | #160
UNIVERSAL CARRIER SPLICE
DRAWING NUMBER: EXT-BOX6-B1.5
SCALE: AS SHOWN
These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an
architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable
for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the
fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure
compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.
*VERTICAL SUPPORTS AND HANGER WIRE OMITTED FOR CLARITY
12'-0" WALL ANGLE TRIM PART LENGTH
1"
1"
1" WALL ANGLE 0.025" ALUMINUM MATERIAL & FINISH TO MATCH, TYPICAL
UNIVERSAL CARRIER
FIELD CUT BOX 6 PANEL ENDS FOR LENGTH AS REQUIRED, TYPICAL
FIELD MITER TRIMS AT CORNERS
BOX 6 PANEL
FIELD CUT BOX 6 PANEL SIDE FOR WIDTH
1"
1"
'A'
1" WALL ANGLE HOLD DOWN
1" WALL ANGLE TO SECURE FIELD CUT PANEL SIDE.
EXTERIOR INSTALLATION
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
MATERIAL: .020" | .025" | .032" | .040" ALUMINUM BOX 6 PANEL | .040"
ALUMINUM UNIVERSAL CARRIER
PERFORATION: NON-PERFORATED | #160
WALL ANGLE TRIM
DRAWING NUMBER: EXT-BOX6-B1.6
SCALE: AS SHOWN
These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an
architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable
for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the
fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure
compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.
EXTERIOR INSTALLATION
10'-0" 1-3/4" J-TRIM PART LENGTH
1- 3/4" J-TRIM* 0.025" ALUMINUM MATERIAL & FINISH TO MATCH, TYPICAL *TRIM WRAPS PANEL & CARRIER
21 4"
113 16 "
1" WALL ANGLE HOLD DOWN
DOUBLE-SIDED ADHESIVE TO SECURE 1" WALL ANGLE OR USE POP-RIVET
21 4"
113 16 "
SECTION 'A' SCALE: 6" = 1'-0" SECTION 'B'
SCALE: 6" = 1'-0"
*SOME VERTICAL SUPPORTS AND HANGER WIRE OMITTED FOR CLARITY
'A'
FLAT RECESSED CLOSURE
FLAT RECESSED CLOSURE
Norcross, GA 30093
MATERIAL: .020" | .025" | .032" | .040" ALUMINUM BOX 6 PANEL | .040"
ALUMINUM UNIVERSAL CARRIER
PERFORATION: NON-PERFORATED | #160
DRAWING NUMBER: EXT-BOX6-B1.7
SCALE: AS SHOWN
These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an
architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable
for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the
fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure
compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.
SECTION 'A' SCALE: 3" = 1'-0"
NOTE: FIXTURE WITH TRIM FLANGE NOT BY CERTAINTEED
627 32*BOX 4 PANEL
12 GA HANGER WIRE AND VERTICAL SUPPORTS, BY OTHERS, TYPICAL
REQUIRED RECESSED CLOSURE
LIGHT FIXTURE INDEPENDENTLY SUPPORTED IN ACCORDANCE WITH LOCAL BUILDING CODES & LIGHT FIXTURE MANUFACTURER'S INSTRUCTIONS
6" X 48" RECESSED FLUORESCENT FIXTURE EXAMPLE WITH FLANGE
UNIVERSAL CARRIER
12 GA HANGER WIRE AND VERTICAL SUPPORT, BY OTHERS, TYPICAL
SECTION 'B' SCALE: 3" = 1'-0"
TOP VIEW SCALE: NOT TO SCALE
FLANGED FIXTURE RECOMMENDED
*627 32" MAX CLEAR OPENING, PANEL EDGE TO PANEL EDGE, FOR SINGLE PANEL INTERRUPTION.
1227 32" MAX CLEAR OPENING, PANEL EDGE TO PANEL EDGE, FOR DOUBLE PANEL INTERRUPTION.
'A' INTERRUPT CARRIER AT FIXTURE LOCATION, TYPICAL INTERRUPT CARRIER AT FIXTURE LOCATION, TYPICAL
'A'
SINGLE PANEL INTERRUPTION.
DOUBLE PANEL INTERRUPTION.
48" FIXTURE LENGTH EXAMPLE
LIGHT FIXTURE INDEPENDENTLY SUPPORTED IN ACCORDANCE WITH LOCAL BUILDING CODES & LIGHT FIXTURE MANUFACTURER'S INSTRUCTIONS
6" MAX, TYPICAL
SEE DETAIL # EXT-BOX6-B1.2 FOR EXTERIOR SPACING REQUIREMENTS BOX 6 PANEL
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
MATERIAL: .020" | .025" | .032" | .040" ALUMINUM BOX 6 PANEL | .040"
ALUMINUM UNIVERSAL CARRIER
PERFORATION: NON-PERFORATED | #160
PROJECT: EXTERIOR BOX 6 PRODUCT SPECIFICATIONS
DRAWING NUMBER: EXT-BOX6-B1.8
SCALE: AS SHOWN
These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an
architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable
for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the
fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure
compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.
SECTION 'A' SCALE: 3" = 1'-0"
NOTE: FIXTURE WITH TRIM FLANGE NOT BY CERTAINTEED
SECTION 'B' SCALE: 3" = 1'-0"
LIGHT FIXTURE INDEPENDENTLY SUPPORTED IN ACCORDANCE WITH LOCAL BUILDING CODES & LIGHT FIXTURE MANUFACTURER'S INSTRUCTIONS
12 GA HANGER WIRE AND VERTICAL SUPPORT, BY OTHERS, TYPICAL
SECTION 'B' SCALE: 3" = 1'-0"
6" MAX, TYPICAL
UNIVERSAL CARRIER
12 GA HANGER WIRE AND VERTICAL SUPPORT, BY OTHERS, TYPICAL
FIXTURE WIDTH VARIABLE
'A'
'B'
'B'
FULL BOX 6 PANEL
LIGHT FIXTURE INDEPENDENTLY SUPPORTED IN ACCORDANCE WITH LOCAL BUILDING CODES & LIGHT FIXTURE MANUFACTURER'S INSTRUCTIONS
6" X 48" RECESSED FLUORESCENT FIXTURE EXAMPLE WITH FLANGE
FULL BOX 6 PANEL BEYOND FLANGED FIXTURE RECOMMENDED6" X 48" RECESSED FLUORESCENT FIXTURE EXAMPLE WITH FLANGE
SEE DETAIL # EXTBOX-B1.2 FOR EXTERIOR SPACING REQUIREMENTS FLANGED FIXTURE RECOMMENDED
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
MATERIAL: .020" | .025" | .032" | .040" ALUMINUM BOX 6 PANEL | .040"
ALUMINUM UNIVERSAL CARRIER
PERFORATION: NON-PERFORATED | #160
DRAWING NUMBER: EXT-BOX6-B1.9
SCALE: AS SHOWN
These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an
architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable
for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the
fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure
compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.
LATERAL BRACING: BRACE WITH HANGER WIRES AND STRUTS PER ASTM E-580 AND IN ACCORDANCE WITH LOCAL CODE REQUIREMENTS.
(4) #12 GAUGE WIRES SPLAYED 90° FROM EACH OTHER AT ANGLE NOT EXCEEDING 45° FROM PLANE OF CEILING. A STRUT FASTENED TO MAIN RUNNER SHALL BE EXTENDED TO AND FASTENED TO STRUCTURE ABOVE. SPLAYED WIRE AND STRUT BRACING TO BE PLACED NOT MORE THAN 12 FEET ON CENTER IN EACH DIRECTION, WITH THE FIRST POINT WITHIN 6 FEET FROM EACH WALL.
BOX 6 PANEL
COMPRESSION STRUT
Norcross, GA 30093
MATERIAL: .020" | .025" | .032" | .040" ALUMINUM BOX 6 PANEL | .040"
ALUMINUM UNIVERSAL CARRIER
PERFORATION: NON-PERFORATED | #160
DRAWING NUMBER: EXT-BOX6-B1.12
SCALE: AS SHOWN
These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an
architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable
for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the
fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure