university of calicut 18.0614.139.185.6/website/tenders/ten1103.pdf · address, protocol, port...
TRANSCRIPT
UNIVERSITY OF CALICUT
(Purchase Division)
168110/PURCHASE-ASST-A1/2017/Admn Calicut University.P.O.
18.06.2018 Re-Tender Notice
Sealed superscribed competitive tenders are invited by the Regislrar, University of Calicut for the
purchase of seven Nos of 24 Ports Network Switches for various departments of Calicut
University . The specifications are provided in the schedule of items given below.
Tender Notice 168110/PURCHASE-ASST-A1/2017/Admn
dated 18.06.2018
Last date and time for receipt of the tender 03.07.2018 4: 00 p.m.
Date and time of opening of the tender 04.07.2018 1:00 a.m.
Designation and address of the officer to whont the tender is to be addressed
he Deputy Registrar, Purchase Division, University of Calicut, Calicut University P.O., Thenhipalam, Malappuram Dt, PIN 673635 PH: 0494-2407130/60
Date up to which rates are to be firm 90 days from acceptance of tender
Superscription Tender for purchase of 24 port Network Switches
The tender form can be downloaded along with General conditions from the University Website (www.universityofcaficut.info) for which separate DD should be enclosed.
Sealed tenders with cost of tender form of Rs. 448/- (inclusive of 12 % GST) and EMD of Rs.1500/- in separate demand drafts in favour of the Finance Officer should be submitted along with the tender documents.
The necessary superscription, due date for the receipt for tenders, the date upto which the rates will have to remain firm for acceptance and the name and address of officer to whom the tender is to be sent are noted above. Any bids received after the time fixed on the due date will be rejected.
The rate quoted should be inclusive of all taxes and all other charges. Including delivery charges to the University of Cahoot, Main Campus, Thenhipalam, Malappuram District, Kerala.
Schedule of item
(Quantity required: 7 numbers)
SPECIFICATION FOR LAYER 2 MANAGED SWITCH
Preferred make/brands Cisco/HP/Junlper
Features Technical specification
The Switch Should have Minimum 24 Port 10/100/1000 Mbps,Base-T and 2 port Gigabit Ethernet combo (RJ45 + SFP(1G)) ports
The Switch should support non-blocking architecture with minimum switching capacity of 56 Gbps
The Offered switch should support minimum 41.67 mpps
of fcrwarding rate (64-byte packets)
The Offered switch should have 32 MB fk.sh and 256 MB CPU memory
layer 3 Switching features
Static Routing/ Layer 3 switching between VLAN's. IPv4 routing should support up to 512 static routes and
up to 128 IP interfaces.
Should support classless inter domain redling (CIDR)
layer 2 Switching 'features
Switch should support Standard 802.1d Spanning Tree support. Fast convergence using 992.1w ;Rapid Spanning
Tree fiRSTP1), enabled by default 8 instAnces are
supported,Multiple Spanning Tree instdnces using
802.1s (MSTP)
Switch should support for IEEE 802.3ad Link Aggregation Control Protocol (LACP), Up to 8 groups, Up to Sports per group with 16 candidate ports for each (dynamic) 802.3ad link aggregation
Switchs should support for up to 4096 . LANs simultaneously, Port-based and 802.1Q tag-based
VLANs,MAC-based VLAN,Management VLAN Private
VLAN Edge (PVE), also known as protected ports, with
multiple uplinks, Guest VLAN,Unauthen&ated
VLAN,Dynamic VLAN assignment via Radius server along
with 802.1x client authentication and CPI VLAN
Switch should support Guest VLAN, Voice VLAN,GVRP/GARP. support Dynamic Host
Configuration Protocol (DHCP) Relay at Layer 2 with
option 82, Internet Group Management Protocol (IGMP)
versions 1,2 and 3 snooping and 256 mu.ticast groups.
The Offered switch should be able to support source based multicasting.
The offered switch should support Head-of-line (HOL) blocking prevention.
Security features
The Switch must have IEEE 802.1X: RADIUS authentication and accounting,Single/multiple host mode. Single/multiple sessions Support for time-based 802.1X, and Dynamic VLAN assignment
The Offered Switch should be able to support Locking of
MAC addresses to ports and should also be capable of limiting the number of learned MAC
The Switch should support RADIUS authentication where switch functions as client.
The Switch should support storm control for Bra dcast, multicast, and unknown unicast.
Thu Switch should support DoS attack prevention.
The Switch should support Access Control List features using which Dropping and rate limiting can be done based
on following:- source and destination MAC , VLAN ID,IP
address, Protocol, Port grouping, Differentiated services
code point (DSCP)/IP Precedence, TCP/UDP source and
destination ports, 802.1p priority.
Quality of Services
features
The offered switch should support Priority levels with 4 hardware queues.
The Switch should support scheduling using Strict priority and weighted rounf-robin (WRR) and Queue 'assignment based on DSCP and class of service (802.1p/CoS)
. . The Switch should be capable of supporting Class of service based on following:-
Port based
802.1p VLAN priority based
Ipv4iv6 P precedence/type of service (ToS)/DSCP based
Differentiated services (DiffServ)
The Switch should support rate limiting using Ingress policer; egress shaping and rate control; per VLAN, per port, and flow based.
The Offered switch should support following IPv6 features:-
IPvt host mode
IPv6 over Ethernet
Dual IPv6/1Pv4 stack
IPvd neighbor and router discovery (ND'i
IPA; stateless address auto-configuration
Patii maximum tranmission unit (MTU) discovery
Duplicate address detection (DAD)
ICMP version 6
Irve over Ipv4 network with Intra-Site Au!emetic Tunnel Addressing Protocol
(ISATAP)
The switch should have support for IPv6 spplication such as Web/SSL, Telnet server/SSH ping trace route, Simple Network Time Protocol (SNIP), Trivial File Transfer Protocol TFTP), SNMP, RADIUS, syslog, DNS client, protocol- based VLANs.
Manangement features The offered switch should have Built-in switch configuration utility of reasy browser-bas id device configuration (HTTP/HTTPS).
The built-in web based utility should he support co figuration, system dashboard, system maintenance,
and monitoring
Thc Switch should support SNMP version 1, 2c and 3 with support for traps, and SNMP version 3 user-based security model (USM)
The Switch should support remote monitoring with Embedded RMON software agent with support of 4
RMON groups (history, statistics, alarms , and events) for enhanced traffic managementm monitori.11 and analysis.
The Switch should support firmware upgrade using web, TFTP and console as well. Switch should support Dual images for resilient firmware upgrades.
The Switch should support port mirroting and Vlan mirroring feature for analysis with a network analyzer or RMON probe.
The Switch should support Text-editable config files easier andifaster mass deployments.
The Switrelevant Kerala government rulea are ch should support minimum 16K mac addresses arid jumbo frames with Frame sizes up to 9 KB supported on Gigabit interfaces. .
The Switch should minimum 16 MB flash and 128 mb cpu meiaory.
Switch should support IEEE 802.3 1OBASE-T Ethernet,
Standards
IEEE 802.3u 100BASE-TX Fast Ethernet IEEE 802.3ab
1000BASE-T Gigabit Ethernet, IEEE 802.2ad LACP, IEEE
802.3z Gigabit Ethernet, IEEE 802.3x Floa Control, IEEE
802.10 (SIP, GARP, and GVRP),IEEE 802.1Q/p
VLAN, IEEE 802.1w RSTP, IEEE 802.1s Multiple STP,
IEEE 802 IX Port Access Authentication, IEEE 802.3af,
IEEE 802.3at.
Switch should support RFC 768, RFC 783, RFC 791, RFC 792, RFC 793, RFC 813, RFC 879, RFC 896, RFC 826,
RFC 854, RFC 855, RFC 856, RFC 858, RFC 894, RFC
919, RFC 922, RFC 920, RFC 950, RFC 1042, RFC 1071,
RFC 1123, RFC 1141, RFC 1155, RFC 1157, RFC 1350,
RFC 1533, RFC 1541, RFC 1624, RFC 1700, RFC 1867,
RFC 2030, RFC 2616, RFC 2131, RFC 2132, RFC 3164,
RFC 3411, RFC 3412, RFC 3413, RFC 3414, RFC 3415,
RFC 2576, RFC 4330, RFC 1213, RFC 1215, RFC 1286,
RFC 1442, RFC 1451, RFC 1493, RFC 1573, RFC 1643,
RFC 1757, RFC 1907, RFC 2011, RFC 2312, RFC 2013,
RFC 2233, RFC 2618, RFC 2665, RFC 2666, RFC 2674,
RFC 2737, RFC 2819, RFC 2863, RFC 1157, RFC 1493,
The Offered switch should meet UL (UL 60950), CSA (CSA 22.2), CE mark, FCC Part 15 (CFR 47) Class A cerNcations.
Warranty
Switch should be provided with hardware rept scement warranty, ongoing software upgrades for
all major and minor releases for a period of 3 years.
Terms and conditions_
The succesful bidder sheil deliver the item within 7 days of the supply order. The successful bidder shall furnish a purchase agreement In F.3.200/- Kerala Stamp paper and furnish security deposit equivalent to 5 percent of the conti act value. The secuirty deposit is returnable after the waitanty period.
3 The rate quoted should tie inclusive of taxes and all other chargesincluding transpOtation. • 4 The GST registration is mandatory for participants in the tende ..The GST number, a copy of
the GST registration certificate shall be enclosed with the tend .11'. 5 All rules as per Kerala Store Purchase manual will be applicable to the tender.
Deputy Registrar
Purcha ed Division
Copy to: The System Administrator (For publication in the University Website)