unprotected openings - realtyninja · black aluminum & glass railing asphalt shingles 2x10 trim...

4
9'-0" MAIN CLG. MAIN FLR. 10" 3'-2" CRAWLSPACE FLR. FRONT ELEVATION 12 6 12 9 ASPHALT SHINGLES HARDI-PLANK SIDING 1x6 TRIM HARDI-PLANK SIDING 1x6 TRIM 12" CEDAR COLUMN ON STONE BASE BLACK ALUMINUM & GLASS RAILING CORRUGATED STEEL 18" DECORATIVE GABLE VENT ASPHALT SHINGLES 2'-0" 2x10 TRIM 2x10 TRIM 2x10 TRIM 24'-3" 3'-6" 1'-6" 6" 1'-6" 1'-6" 1'-6" RIGHT ELEVATION UNPROTECTED OPENINGS: WALL AREA: 616 SQ. FT. LIMITING DISTANCE: 4'-0" PERMITTED OPENINGS: 43.12 SQ. FT. 7.00% PROPOSED OPENINGS: 42 SQ. FT. 6.78% 9 12 6 12 ASPHALT SHINGLES HARDI-PLANK SIDING 1x6 TRIM HARDI-PLANK SIDING 1x6 TRIM 12" CEDAR COLUMN ON STONE BASE BLACK ALUMINUM & GLASS RAILING ASPHALT SHINGLES 2x10 TRIM 2x10 TRIM 12" CEDAR COLUMN CONCRETE PATIO 1'-6" 1'-6" 1'-6" 2'-0" LINE OF VAULT IN GREAT RM. 3'-6" REAR ELEVATION 12 9 12 6 12 9 LINE OF VAULT 12" CEDAR COLUMN 2x10 TRIM ASPHALT SHINGLES HARDI-PLANK SIDING 1x6 TRIM HARDI-PLANK SIDING 1x6 TRIM CORRUGATED STEEL ASPHALT SHINGLES 2x10 TRIM 2x10 TRIM 1'-6" 1'-6" 1'-6" 1'-6" 6" 2x10 TRIM CONCRETE PATIO LEFT ELEVATION 12 6 12 9 UNPROTECTED OPENINGS: WALL AREA: 66 SQ. FT. LIMITING DISTANCE: 31'-6" PERMITTED OPENINGS: 66.00 SQ. FT. 100.00% PROPOSED OPENINGS: 25 SQ. FT. 37.96% UNPROTECTED OPENINGS: WALL AREA: 550 SQ. FT. LIMITING DISTANCE: 4'-0" PERMITTED OPENINGS: 38.50 SQ. FT. 7.00% PROPOSED OPENINGS: 30 SQ. FT. 5.38% HARDI-PLANK SIDING 1x6 TRIM 12" CEDAR COLUMN ON STONE BASE BLACK ALUMINUM & GLASS RAILING ASPHALT SHINGLES 2x10 TRIM 2'-0" 3'-6" 2x10 TRIM ASPHALT SHINGLES HARDI-PLANK SIDING 1x6 TRIM 12" CEDAR COLUMN CONCRETE PATIO 1'-6" 1'-6" 1'-6" 1'-6" 1'-6" 1'-6" THESE PLANS HAVE BEEN DESIGNED IN ACCORDANCE WITH THE 2012 EDITION OF THE B.C. BUILDING CODE Elevations Drawing Title Sheet Number Date Designed/Drawn By Checked Scale Project Drawn By: www.i3design.ca Burnaby, B.C. Fax: 604.662.8078 4723 Hastings Street V5C 2K8 Tel: 604.662.8008 3 i design Key Plan Client COPYRIGHT RESERVED. THIS DRAWING IS AND AT ALL TIMES REMAINS THE EXCLUSIVE PROPERTY OF THE DEVELOPER AND CAN NOT BE USED OR DUPLICATED WITHOUT WRITTEN CONSENT CONTRACTORS ARE RESPONSIBLE FOR THE VERIFICATION OF ALL DIMENSIONS AND SITE CONDITIONS PRIOR TO ANY CONSTRUCTION OR FABRICATION. ANY DISCREPANCIES ARE TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DEVELOPER. May 29, 2018 Genica 05/29/18 1 Aquadel Crossing II Rancher Plan B1L Lot 0 Revisions Description Date # Project North Developments Issued for Review 06/01/18 2 Brick Replaced with Stone 07/12/18 3 Plan Mirrored 4 Issued for Permit 07/12/18 1/4"=1'-0" GM GM/NP Do not scale the drawings. This drawing is a copyright drawing and shall not be reproduced or revised without written permission from the designer. The General Contractor shall check and verify all dimensions and report all errors and omissions to Designer. A2.0

Upload: others

Post on 31-Jul-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

9'-0

"

MAIN CLG.

MAIN FLR.

10"

3'-2

"

CRAWLSPACE FLR.

FRONT ELEVATION

12

6

12

9

ASPHALTSHINGLES

HARDI-PLANKSIDING

1x6 TRIM

HARDI-PLANKSIDING

1x6 TRIM

12" CEDARCOLUMN ONSTONE BASE

BLACK ALUMINUM& GLASS RAILING

CORRUGATEDSTEEL

18" DECORATIVEGABLE VENT

ASPHALTSHINGLES

2'-0"

2x10 TRIM2x10 TRIM

2x10 TRIM

24

'-3"

3'-6

"

1'-6"

6"1'-6"1'-6"1'-6"

RIGHT ELEVATION

UNPROTECTED OPENINGS:WALL AREA: 616 SQ. FT.LIMITING DISTANCE: 4'-0"PERMITTED OPENINGS: 43.12 SQ. FT. 7.00%PROPOSED OPENINGS: 42 SQ. FT. 6.78%

9

12

6

12

ASPHALTSHINGLES

HARDI-PLANKSIDING

1x6 TRIM

HARDI-PLANKSIDING

1x6 TRIM

12" CEDARCOLUMN ONSTONE BASE

BLACK ALUMINUM& GLASS RAILING

ASPHALTSHINGLES 2x10 TRIM

2x10 TRIM

12" CEDARCOLUMN

CONCRETEPATIO

1'-6"1'-6"1'-6"

2'-0"

LINE OF VAULT INGREAT RM.

3'-6

"

REAR ELEVATION

12

912

6

12

9

LINE OF V

AULT

12" CEDARCOLUMN

2x10 TRIM

ASPHALTSHINGLES

HARDI-PLANKSIDING

1x6 TRIM

HARDI-PLANKSIDING

1x6 TRIM

CORRUGATEDSTEEL

ASPHALTSHINGLES

2x10 TRIM

2x10 TRIM

1'-6"1'-6"1'-6"1'-6"6"

2x10 TRIM

CONCRETE PATIO

LEFT ELEVATION

12

6

12

9

UNPROTECTED OPENINGS:WALL AREA: 66 SQ. FT.LIMITING DISTANCE: 31'-6"PERMITTED OPENINGS: 66.00 SQ. FT. 100.00%PROPOSED OPENINGS: 25 SQ. FT. 37.96%

UNPROTECTED OPENINGS:WALL AREA: 550 SQ. FT.LIMITING DISTANCE: 4'-0"PERMITTED OPENINGS: 38.50 SQ. FT. 7.00%PROPOSED OPENINGS: 30 SQ. FT. 5.38%

HARDI-PLANKSIDING

1x6 TRIM

12" CEDARCOLUMN ONSTONE BASE

BLACK ALUMINUM& GLASS RAILING

ASPHALTSHINGLES

2x10 TRIM

2'-0"3'-6

"

2x10 TRIM

ASPHALTSHINGLES

HARDI-PLANKSIDING

1x6 TRIM

12" CEDARCOLUMN

CONCRETEPATIO

1'-6" 1'-6" 1'-6" 1'-6"1'-6"1'-6"

THESE PLANS HAVE BEEN DESIGNED IN ACCORDANCEWITH THE 2012 EDITION OF THE B.C. BUILDING CODE

Elevations

Drawing Title

Sheet Number

Date

Designed/Drawn By Checked

Scale

Project

Drawn By:

www.i3design.ca

Burnaby, B.C. Fax: 604.662.8078

4723 Hastings Street

V5C 2K8

Tel: 604.662.8008

3

i design

Key Plan

Client

COPYRIGHT RESERVED. THIS DRAWING IS AND AT ALL TIMES REMAINS THE EXCLUSIVE

PROPERTY OF THE DEVELOPER AND CAN NOT BE USED OR DUPLICATED WITHOUT WRITTEN

CONSENT

CONTRACTORS ARE RESPONSIBLE FOR THE VERIFICATION OF ALL DIMENSIONS AND SITE

CONDITIONS PRIOR TO ANY CONSTRUCTION OR FABRICATION. ANY DISCREPANCIES ARE TO BE

BROUGHT TO THE IMMEDIATE ATTENTION OF THE DEVELOPER.

May 29, 2018

Genica

05/29/181

Aquadel Crossing II

Rancher Plan B1L

Lot 0

Revisions

Description

Date#

Project North

Developments

Issued for Review

06/01/182

Brick Replaced with Stone

07/12/183Plan Mirrored

4Issued for Permit 07/12/18

1/4"=1'-0"

GMGM/NP

Do not scale the draw

ings.

This draw

ing is a copyright draw

ing and shall not be reproduced or revised w

ithout w

ritten perm

ission from

the designer.

The G

eneral Contractor shall check and verify all dim

ensions and report all errors and om

issions to D

esigner.

A2.0

CRAWLSPACE ACCESSOPENING MINIMUM 193

4" x 27 58" (500mm x700mm) AS PERSENTENCE B.9.18.2.1.(1)OF B.C.B.C. 2012.

CORBELLED FOUNDATION

RAISED FOUNDATIONAROUND GARAGE TOALIGN WITH TOP OFCORBEL.

CRAWL SPACE

FOUNDATION PLAN

CRAWL SPACE

40'-6"

19'-6" 1'-0"20'-0"

13'-6"5'-0"1'-0"1'-6"16'-0"2'-6"

6" 4"

8"

6"1'-6" 10'-6" 1'-6"

2" 6"

62'-6

"

4'-0

"2'-0

"49'-6

"8'-0

"3'-0

"

4'-6

"45'-0

"

62'-6

"

2'-0

"4'-6

"50'-0

"6'-0

"4'-0

"

2'-0

"16'-8

"2'-1

0"

29

'-6"

40'-6"

1'-0"11'-0"15'-6"13'-0"

4" 11'-0"8"

13'-6" 14'-2" 11'-10"

7'-4" 11'-10"

6'-0

"4'-6

"

6'-0

"6'-2

"17'-1

0"

3'-0

"22'-4

"6'-8

"

15'-2

"28'-1

0"

1'-0

"

20'-4"

20'-6

"6'-6

"23'-0

"

FOUNDATIONAROUNDPORCH TO BE6" BELOW TOPOF CORBEL TOALLOW FORCONCRETE PAD

CONCRETEPORCH AREABACKFILLED

CONCRETEPATIO AREABACKFILLED

FOUNDATION AROUND PATIOTO BE 6" BELOW TOP OFCORBEL TO ALLOW FORCONCRETE PAD

4" LEDGE FORSTONE COLUMNBASE ABOVE

4" LEDGE FOR STONECOLUMN BASE ABOVE

SWITCH ONU/S OF FLRJST.

GARAGE

BEDROOM 2

ENSUITE

DEN

DWSPACE

FRIDGE

PANTRY

RANGESPACE

KITCHEN

2668

SLOPED CEILING

DINING

GREAT ROOM

MASTER BEDROOM

5'-0"x3'-0"SHOWER

ACCESSPANEL TO

CRAWLSPACE

WASHERSPACE

DRYERSPACE

2868

2868

LIN.

BATH

PORCH

LNDRY

W.I.C.

CONCRETE PATIO

HUTC

H S

PACE

2640

16080 O.H. DOOR

36602060 206026602660

4016

5040

3646

26602660

2868

2668

2668

2668

2468

4068

11'-0"x12'-0"

13'-0"x16'-0"

14'-0"x17'-6"

10'-6"x11'-6"

11'-0"x13'-6"

10'-2"x12'-0"

MAIN FLOOR PLAN

FLOOR AREA = 1600 SQ.FT.

20'-0"x20'-0"

3068 W/ 3010 TRANS.

3068 W

/ 3010 T

RANS.

14'-6"x10'-0"

62'-0

"

19'-6"x6'-0" / 10'-6"

6650

FOYER

40'-6"

5068

4068

2068

COVERED

6'-0

"50'-0

"6'-0

"4'-0

"

2'-0

"4'-0

"20'-6

"12'-8

"1

6'-1

0"

18'-0

"2'-6

"9'-0

"

62'-0

"

6'-0

"45'-0

"8'-0

"3'-0

"4'-0

"

12'-6

"5'-4

"11'-1

0"

15

'-4"

2'-1

0"

2'-6

"6'-1

"5'-9

"8'-9

"

1'-0

"

1'-0

"

1'-0

"

2'-0"

2'-0

" 2'-0"

2'-0

"

6"

40'-6"

1'-0"13'-6"5'-0"21'-0"

6'-9"6'-9"2'-6"2'-6"10'-6"10'-6"

1'-0" 1'-0"

6"

6"2'-0"

1'-0"

1'-0"12'-0"27'-6"

13'-0" 14'-6"

1'-0"

12'-0"

4'-6"3'-0"4'-6"3'-6"3'-3"3'-3"4'-6"4'-6"3'-0"5'-6"

1'-0"

1'-0

"

1'-0

"

13'-6" 2'-0" 12'-0" 12'-0"

3'-0" 3'-0" 3'-6" 2'-6"

7'-6" 6'-0" 14'-0" 9'-6" 2'-6"

5'-6" 2'-0" 7'-4" 4'-6" 11'-0" 1'-0"8'-2"

5'-6" 6'-10" 3'-4" 4'-10"

2'-6" 6'-6" 10'-0"

15°

2'-6" 11'-0"

3'-0

"6'-0

"5'-6

"6'-2

"6'-6

"2'-6

"2'-4

"18

'-0"

6'-6

"7'-0

"4'-0

"

2'-4

"4'-6

"7'-0

"

SPACE

6'-3

"6

'-0"

6'-1

"4'-6

"

2'-6

"3

'-6"

CEILING OUTLETFOR GARAGEDOOR OPENER

DECORATIVEHALF-WALLWITH OPENSHELVING

D.V

.F.P

.THESE PLANS HAVE BEEN DESIGNED IN ACCORDANCEWITH THE 2012 EDITION OF THE B.C. BUILDING CODE

Main Floor Plan

Foundation Plan

NOTE: ELECTRICAL LAYOUT FOR REFERENCEONLY. ALL ELECTRICAL PANEL AND ELECTRICBASEBOARD HEATER LOCATIONS TO BEDETERMINED BY ELECTRICAL ENGINEER.

Do not scale the draw

ings.

This draw

ing is a copyright draw

ing and shall not be reproduced or revised w

ithout w

ritten perm

ission from

the designer.

The G

eneral Contractor shall check and verify all dim

ensions and report all errors and om

issions to D

esigner.

T

A3.0

Drawing Title

Sheet Number

Date

Designed/Drawn By Checked

Scale

Project

Drawn By:

www.i3design.ca

Burnaby, B.C. Fax: 604.662.8078

4723 Hastings Street

V5C 2K8

Tel: 604.662.8008

3

i design

Key Plan

Client

COPYRIGHT RESERVED. THIS DRAWING IS AND AT ALL TIMES REMAINS THE EXCLUSIVE

PROPERTY OF THE DEVELOPER AND CAN NOT BE USED OR DUPLICATED WITHOUT WRITTEN

CONSENT

CONTRACTORS ARE RESPONSIBLE FOR THE VERIFICATION OF ALL DIMENSIONS AND SITE

CONDITIONS PRIOR TO ANY CONSTRUCTION OR FABRICATION. ANY DISCREPANCIES ARE TO BE

BROUGHT TO THE IMMEDIATE ATTENTION OF THE DEVELOPER.

May 29, 2018

Genica

05/29/181

Aquadel Crossing II

Rancher Plan B1L

Lot 0

Revisions

Description

Date#

Project North

Developments

Issued for Review

06/01/182

Brick Replaced with Stone

07/12/183Plan Mirrored

4Issued for Permit 07/12/18

1/4"=1'-0"

GMGM/NP

GARAGE

BEDROOM 2

ENSUITE

DEN

KITCHEN

SLOPED CEILING

DINING

GREAT ROOM

MASTER BEDROOM

BATH

PORCH

LNDRY

W.I.C.

CONCRETE PATIO

11'-0"x12'-0"

13'-0"x16'-0"

14'-0"x17'-6"

10'-6"x11'-6"

11'-0"x13'-6"

10'-2"x12'-0"

STRUCTURAL PLAN

MAIN

20'-0"x20'-0"

14'-6"x10'-0"

19'-6"x6'-0" / 10'-6"

FOYER

COVERED

CRAWL SPACE

STRUCTURAL PLAN

CRAWL SPACE

FOUNDATION

THESE PLANS HAVE BEEN DESIGNED IN ACCORDANCEWITH THE 2012 EDITION OF THE B.C. BUILDING CODE

Structural Plans

Do not scale the draw

ings.

This draw

ing is a copyright draw

ing and shall not be reproduced or revised w

ithout w

ritten perm

ission from

the designer.

The G

eneral Contractor shall check and verify all dim

ensions and report all errors and om

issions to D

esigner.

A4.0

Drawing Title

Sheet Number

Date

Designed/Drawn By Checked

Scale

Project

Drawn By:

www.i3design.ca

Burnaby, B.C. Fax: 604.662.8078

4723 Hastings Street

V5C 2K8

Tel: 604.662.8008

3

i design

Key Plan

Client

COPYRIGHT RESERVED. THIS DRAWING IS AND AT ALL TIMES REMAINS THE EXCLUSIVE

PROPERTY OF THE DEVELOPER AND CAN NOT BE USED OR DUPLICATED WITHOUT WRITTEN

CONSENT

CONTRACTORS ARE RESPONSIBLE FOR THE VERIFICATION OF ALL DIMENSIONS AND SITE

CONDITIONS PRIOR TO ANY CONSTRUCTION OR FABRICATION. ANY DISCREPANCIES ARE TO BE

BROUGHT TO THE IMMEDIATE ATTENTION OF THE DEVELOPER.

May 29, 2018

Genica

05/29/181

Aquadel Crossing II

Rancher Plan B1L

Lot 0

Revisions

Description

Date#

Project North

Developments

Issued for Review

06/01/182

Brick Replaced with Stone

07/12/183Plan Mirrored

4Issued for Permit 07/12/18

1/4"=1'-0"

GMGM/NP

ROOF PLAN

ROOF NOTES: ASPHALT SHINGLE / STEEL ROOFING ALL ROOF OVERHANGS TO BE 1'-6"UNLESS NOTED OTHERWISE18" OVERHANG OVER GABLE FACES PRE-FINISHED METAL GUTTER ON 2x6

PAINTED FASCIA BOARD SEE OVERHANG SPECIFICATIONS LOW SLOPE SHINGLES TO BE USED ANDINSTALLED AS PER B.C.B.C. 9.26.8WHERE ROOF PITCH IS LESS THAN4/12.

6/12

6/12

6/12

9/12 9/12

9/12

9/129/12

9/12

9/12

9/12

3'-6"3'-6"

3'-6

"

SECTION A

6

CORBELLEDFOUNDATION

2'-0

"

3

6

2'-0

"

CRAWLSPACE

4'-0

"

3'-2

"10"

9'-1

"

KITCHENGREAT ROOMMASTER BEDROOM

2

1

LOAD BEARING WALLS

12

6

12

9

12

6

1'-6"1'-6"

1'-6" 1'-6"

CORBELLEDFOUNDATION

2

5

4

5

3

12

9

ASSEMBLY SPECIFICATIONS:

1. ROOF ASSEMBLY:

ASPHALT SHINGLES / STEEL ROOFING 7/16" PLYWOOD SHEATHING INSULATION STOP 2" CLEARANCE 2x12 ROOF RAFTERS @ 24" O.C. W/ 2x4 CROSS STRAPPING @ 24" O.C. OR

ENGINEERED ROOF TRUSSES (SEE PLANS) VINYL SOFFIT

2. CEILING ASSEMBLY:

MINIMUM R-40 BATT INSULATION 6 mil POLY VAPOUR BARRIER 5/8" GYPSUM WALL BOARD

3. EXTERIOR RAINSCREEN WALL ASSEMBLY:

EXTERIOR FINISH PRESSURE TREATED STRAPPING OR APPROVED EQUIVALENT BUILDING PAPER 3/8" SHEATHING 2x6 WALL STUDS @ 16" O.C. AS PER PLAN R-20 F.G. BATT INSULATION 6 MIL. POLY VAPOUR BARRIER 1/2" GYPSUM WALL BOARD

4. INTERIOR WALL ASSEMBLY:

1/2" GYPSUM WALL BOARD ON EACH FACE OF 2x4 WALL STUDS @ 16" O.C.

5. FLOOR ASSEMBLY:

FINISH FLOOR 5/8" T&G PLYWOOD (GLUED & NAILED) 2x10 FLOOR JOISTS @ 16" O.C. 2x2 CROSS BRIDGING @ 6'-10" MAXIMUM

6. FOUNDATION ASSEMBLY:

FOUNDATION WALL: 5/8" ANCHOR BOLTS @ 4'-0" O.C. 2 COATS ASPHALT EMULSION (BELOW GRADE) 8" CONCRETE WALL 2" RIGID INSULATION 18"x8" CONCRETE FOOTING 2-15M BARS 4" DIAMETER DRAIN TILE 6" MIN. DRAIN GRAVEL COVER

INTERIOR BEARING WALL: 2x6 WALL STUDS @ 16" O.C. 6" CONCRETE CURB 18"x8" CONCRETE FOOTING

ALL FOOTINGS TO BEAR ON UNDISTURBED NATIVE SOIL BELOW MAXIMUMFROST PENETRATION DEPTH

CRAWL SPACE FLOOR: 2" CONCRETE SKIM COAT 6 MIL POLY VAPOUR BARRIER

SECTION B

5

GARAGE

CRAWLSPACE

1

2

4

3

6

CORBELLEDFOUNDATION

6

CORBELLEDFOUNDATION

GREAT ROOM

GARAGEMAN DOOR

DOOR TOMECH. SPACE

DOOR TOM. BEDROOM

3

9'-0

"10"

3'-2

"

4'-0

"

1'-6"1'-6"

12

6

11'-0

"9'-0

"2'-0

"

CONCRETE PATIO

COVERED

LINE OF FOOTINGBEYOND

LOAD BEARINGWALL

6/1

2SLO

PE C

LG.

12'-4

1 2"

Building Sections

Roof Plan

THESE PLANS HAVE BEEN DESIGNED IN ACCORDANCEWITH THE 2012 EDITION OF THE B.C. BUILDING CODE

Do not scale the draw

ings.

This draw

ing is a copyright draw

ing and shall not be reproduced or revised w

ithout w

ritten perm

ission from

the designer.

The G

eneral Contractor shall check and verify all dim

ensions and report all errors and om

issions to D

esigner.

Assembly Specs

A5.0

Drawing Title

Sheet Number

Date

Designed/Drawn By Checked

Scale

Project

Drawn By:

www.i3design.ca

Burnaby, B.C. Fax: 604.662.8078

4723 Hastings Street

V5C 2K8

Tel: 604.662.8008

3

i design

Key Plan

Client

COPYRIGHT RESERVED. THIS DRAWING IS AND AT ALL TIMES REMAINS THE EXCLUSIVE

PROPERTY OF THE DEVELOPER AND CAN NOT BE USED OR DUPLICATED WITHOUT WRITTEN

CONSENT

CONTRACTORS ARE RESPONSIBLE FOR THE VERIFICATION OF ALL DIMENSIONS AND SITE

CONDITIONS PRIOR TO ANY CONSTRUCTION OR FABRICATION. ANY DISCREPANCIES ARE TO BE

BROUGHT TO THE IMMEDIATE ATTENTION OF THE DEVELOPER.

May 29, 2018

Genica

05/29/181

Aquadel Crossing II

Rancher Plan B1L

Lot 0

Revisions

Description

Date#

Project North

Developments

Issued for Review

06/01/182

Brick Replaced with Stone

07/12/183Plan Mirrored

4Issued for Permit 07/12/18

1/4"=1'-0"

GMGM/NP