use of hydro test (g-10)
TRANSCRIPT
![Page 1: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/1.jpg)
1
Use of Hydro Test
PRESENTED BY: HARDISH TRIVEDI
![Page 2: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/2.jpg)
3
Tests Destructive Tests
Tensile, Impact, Bend,etc
Non-destructive Tests
Radiography,
Ultrasonic,
Dye-penetration,
Magnetic Particle
and leak testing like
Hydrotest, Air Test, Helium Test etc.. PRESENTED BY: HARDISH
TRIVEDI
![Page 3: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/3.jpg)
4
Hydrotest-------why?
Recommended For pressure vessel operatingunder pressure
Ensures the strength of weld joints &materials
Ensures nozzle-flange joint
Test The strength of The pressure vessel at1.5 times the designed pressure
Ensures safe & reliable performance duringthe operational life
To ensure the integrity of the vessel and system operation under pressure.
PRESENTED BY: HARDISH TRIVEDI
![Page 4: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/4.jpg)
5
Requirements Of Materials , Tools & Equipments
TEST MEDIUM • WATER WITH ‘X’ PPM AS FREELY AVAILABLE• (PARTS PER MILLION---CHLORINE IMPURITIES)
• ‘X’ ---- 25 PPM OR LESS FOR SS VESSEL• ‘X’ ---- 80 PPM OR LESS FOR CS VESSEL
• CHLORINE PARTICLES AFFECT THE ANTICORROSIVE PROPERTIES OF VESSEL
PRESENTED BY: HARDISH TRIVEDI
![Page 5: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/5.jpg)
6
REQUIREMENTS OF MATERIALS , TOOLS & EQUIPMENTS-(CONTD.)
WOODEN SADDLES (SOFT WOOD)• TO SUPPORT THE VESSEL & AVOID ANY
DEFORMATION OR DENT AT CONTACT SURFACES
• CONTACT ANGLE---120 DEGREES
1200
Vessel
Wooden saddle PRESENTED BY: HARDISH
TRIVEDI
![Page 6: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/6.jpg)
7
REQUIREMENTS OF MATERIALS , TOOLS & EQUIPMENTS-(CONTD.)
THERMOCOL SHEETS
• 20--30 MM THICKNESS• USED AS A SOFT PACKING BETWEEN VESSEL &
SADDLE
PRESENTED BY: HARDISH TRIVEDI
![Page 7: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/7.jpg)
8
REQUIREMENTS OF MATERIALS , TOOLS & EQUIPMENTS-(CONTD.)
COVER FLANGES
• NOZZLES WHICH HAVE ORIGINAL BLIND FLANGES TO BE BLANKED BY THOSE FLANGES
• OTHER NOZZLES TO BE BLANKED AS PER SPECIFIED DRAWING
PRESENTED BY: HARDISH TRIVEDI
![Page 8: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/8.jpg)
9
REQUIREMENTS OF MATERIALS , TOOLS & EQUIPMENTS-(CONTD.)
HIGH TENSILE FASTNERS
• TO BE USED AS SPECIFIED IN THE DRAWING
PRESENTED BY: HARDISH TRIVEDI
![Page 9: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/9.jpg)
10
REQUIREMENTS OF MATERIALS , TOOLS & EQUIPMENTS-(CONTD.)
PIPE FITTING
• HIGH PRESSURE (5000 TO 10000 PSI)• REQUIRED SIZES (BSP,NPT) TO BE USED FOR
INLET & OUTLET EQUIPMENT, VALVES, GAUGES CONNECTIONS
PRESENTED BY: HARDISH TRIVEDI
![Page 10: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/10.jpg)
11
PUMP ACCESSORIES
• SQUARE BAR
• SHUT OFF VALVE
• COUPLER
• FLOW DIRECTION
PRESENTED BY: HARDISH TRIVEDI
![Page 11: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/11.jpg)
12
REQUIREMENTS OF MATERIALS , TOOLS & EQUIPMENTS-(CONTD.)
GASKETS
• TO BE USED JOB GASKET UNLESS OTHERWISE SPECIFIED
PRESENTED BY: HARDISH TRIVEDI
![Page 12: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/12.jpg)
13
REQUIREMENTS OF MATERIALS , TOOLS & EQUIPMENTS-(CONTD.)
PRESSURE GAUGES
• USE MINIMUM TWO CALIBRATED PRESSURE GAUGES
• RANGE--- MIN. 1.5 TIMES THE TEST PRESSURE MAX. 4 TIMES THE TEST PRESSURE
• EXAMPLE: FOR TEST PRESSURE OF 60 KG/CM2 RANGE SHOULD BE 0-100 KG/CM2
(OR) 0-240 KG/CM2
PRESENTED BY: HARDISH TRIVEDI
![Page 13: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/13.jpg)
14
• SQUARE BAR
• SHUT OFF VALVE
• COUPLER
• PRESSURE GAUGE
PUMP ACCESSORIES
PRESENTED BY: HARDISH TRIVEDI
![Page 14: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/14.jpg)
15
REQUIREMENTS OF MATERIALS , TOOLS & EQUIPMENTS-(CONTD.)
WATERPUMP & HOSE ASSEMBLIES
• SUBMERSSIBLE OR ANY OTHER PUMP IS USED FOR FILLING THE VESSEL
• CONNECTED THROUGH FLEXIBLE HOSE PIPES TO TANK & VESSEL
PRESENTED BY: HARDISH TRIVEDI
![Page 15: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/15.jpg)
16
REQUIREMENTS OF MATERIALS , TOOLS & EQUIPMENTS-(CONTD.)
HYDROTEST PUMP• REQUIRED FOR PRESSURIZING THE VESSEL TO
THE TEST PRESSURE• COMPRISES OF
A HIGH PRESSURE PUMP
B NON-RETURN VALVE
C RELIEF VALVES
D ATTACHMENTS LIKE HOSES, COUPLERS
PRESENTED BY: HARDISH TRIVEDI
![Page 16: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/16.jpg)
17
PUMP ACCESSORIES
• PRESSURE GAUGE
• SUBMISSILE
PUMP
• OUTLET HOSE
PRESENTED BY: HARDISH TRIVEDI
![Page 17: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/17.jpg)
18
REQUIREMENTS OF MATERIALS , TOOLS & EQUIPMENTS-(CONTD.)
TORQUE WRENCH, GUN & STUD TENSIONER
• ALL THE OPENINGS MUST BE CLOSED WITH BLIND FLANGES
• TIGHTENING TO BE ENSURED AT DESIRED TORQUE BY TORQUING WRENCH, TORQUING GUN OR STUD TENSIONER
PRESENTED BY: HARDISH TRIVEDI
![Page 18: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/18.jpg)
19
TYPES OF HYDROTEST PUMP
• HIGH DISCHARGE LOW PRESSURE
PRESSURE RANGE : UP TO 100 KG/SQ.CM(g)
QTY. : 02
• LOW DISCHARGE HIGH PRESSURE
PRESSURE RANGE : UP TO 400 KG/SQ.CM(g)
QTY. : 06
PRESENTED BY: HARDISH TRIVEDI
![Page 19: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/19.jpg)
20
HYDROTEST PUMP DETAILS(HIGH PRESSURE, LOW DISCHARGE)
• INLET HOSE• TANK
• TROLLEY
• OUTLET HOSE
PRESENTED BY: HARDISH TRIVEDI
![Page 20: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/20.jpg)
21PRESENTED BY: HARDISH TRIVEDI
![Page 21: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/21.jpg)
22
SEQUENCE OF OPERATIONS
SADDLE ARRANGEMENT• REQUIRED NO. OF SADDLES AS
MENTIONED ON DRG. TO BE PLACED AT THE DISTANCES
• PUT THERMOCOL SHEETS ON SADDLES BEFORE KEEPING THE VESSEL
PRESENTED BY: HARDISH TRIVEDI
![Page 22: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/22.jpg)
23
SEQUENCE OF OPERATIONS (CONTD.)
ORIENTATION• LONGSEAM, CIRCSEAM REMAIN
EXPOSED FOR VISUAL INSPECTION & NOT COVERED UNDER SADDLE
• INLET NOZZLE FOR WATER IS AT THE TOP & DRAIN OUT AT THE BOTTOM OF VESSEL
PRESENTED BY: HARDISH TRIVEDI
![Page 23: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/23.jpg)
24
SEQUENCE OF OPERATIONS (CONTD.)
AIR LOCK REMOVAL• ADEQUATE ARRANGEMENT TO BE MADE
FOR VENTING THE AIR, TRAPPED INSIDE THE VESSEL
• FOUR DIFFERENT CASES TO BE STUDIED
PRESENTED BY: HARDISH TRIVEDI
![Page 24: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/24.jpg)
25
AIR LOCK REMOVAL
1 VESSEL IN HORIZONTAL, INCLINED AT 5 DEG.
PRESENTED BY: HARDISH TRIVEDI
![Page 25: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/25.jpg)
26
AIR LOCK REMOVAL2. WHEN INTERNALS LIKE TSRs PROVIDED INSIDE THE VESSEL
VESSEL
SADDLE NOZZLE
D/E
PRESENTED BY: HARDISH TRIVEDI
![Page 26: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/26.jpg)
27
AIR LOCK REMOVAL
3 FOR HORIZONTAL NOZZLE INSIDE THE D/E
PRESENTED BY: HARDISH TRIVEDI
![Page 27: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/27.jpg)
28
AIR LOCK REMOVAL
PRESENTED BY: HARDISH TRIVEDI
![Page 28: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/28.jpg)
29
TIGHTENING SEQUENCE
Bitmap Image
1
2
34
5
6 7
8
PRESENTED BY: HARDISH TRIVEDI
![Page 29: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/29.jpg)
30
PRESSURE VALVE SETTING
• VALVE SETTING FOR REQUIRED PRESSURE
PRESENTED BY: HARDISH TRIVEDI
![Page 30: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/30.jpg)
31
GUIDELINES FOR HYDROTEST• Pump shaft should rotate clock wise looking
from shaft side
• Ensure bypass line is open.
• Ensure that bypass line should not connect to the pump suction line.
(If discharge line is shut off, bypass water is diverted to the pump suction & as a result there is a rapid rise in temperature , which causes damage to piston plunger packing)
PRESENTED BY: HARDISH TRIVEDI
![Page 31: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/31.jpg)
32
• Connect pump outlet to vessel inlet through
standard hose pipe, with proper valve connections, square bar, couplers, etc.
• Ensure the pressure regulator valve,foot valve,should be in unloading position.
• Ensure the pressure gauge calibration validity
• Ensure water tank or suction line should be free from any foreign material
PRESENTED BY: HARDISH TRIVEDI
![Page 32: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/32.jpg)
33
• Start hydrotest pump
• Ensure 100% removal of entrapped air
( monitor the tank into which the outlet hose pipe is dipped. As soon as bubbles stop showing up, close outlet valve)
• Monitor pressure gauge provided at outlet.
OPERATING PROCEDURES
PRESENTED BY: HARDISH TRIVEDI
![Page 33: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/33.jpg)
34
OPERATING PROCEDURES
• As soon as pressure reaches 50% of the test pressure , wait for 10 minutes
• Increase pressure by 10% in stages till the test pressure is achieved
• Observe pressure drop
• ( by marking line on pressure gauges)
PRESENTED BY: HARDISH TRIVEDI
![Page 34: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/34.jpg)
35
• Hold the hydrotest pressure for specific time as mentioned in drawing
• Carry out thorough visual inspection of all joints & connections
(If any leakage is noticed, mark the point. The vessel is to be depressurized and then necessary repairs are to be carried out. Again the test procedure is to be repeated)
PRESENTED BY: HARDISH TRIVEDI
![Page 35: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/35.jpg)
37
DOs & DON’Ts
• Ensure pressure gauge readability
• Working, design & test pressure to be displayed near the vessel
• Ensure all gasket surfaces are free from dent & scratches before blanking
• Do not apply paint, oil, grease on weld joints
• Do not weld on job blind flangePRESENTED BY: HARDISH TRIVEDI
![Page 36: Use of Hydro test (G-10)](https://reader033.vdocument.in/reader033/viewer/2022061119/546a6ba6b4af9f61098b47ff/html5/thumbnails/36.jpg)
38PRESENTED BY: HARDISH TRIVEDI