User Benefits and features
66
AvailabilityPower
Performance& Efficiency
Flexibility Manageability
Delta Confidential
Wide I/P Voltage and O/P Voltage Regulation
Wide input voltage range*: -40~20%, reduces the chance of using the battery.
Voltage regulation:Output voltage regulation < ± 1 %, provides stable power supply.
7
This design allows the UPS to operate in harsh electrical environments and provide a stable power supply.
* Note: Full load: -25%~+20%
• Over Voltage• Transient
• Output Voltage (±1% regulation)
Availability
Delta Confidential
DSP Intelligent Control
8
Simplification of the control circuit to enhance the flexibility and stability
Reduction in the number of electronic components to lower failure rate
Increased reliability achieved by fail-safe detection of DSP allowing to automatically transfer to static bypass when DSP failed.
* Note: Digital Signal Processor
Faster computation capability to enhance system stability and provide precise voltage to load
Availability
Delta Confidential
Inbuilt Manual Bypass
9
The design ensures system availability during service maintenance.
AC/DC
BYPASS INPUT
MAIN INPUT
OUTPUTDC/AC
UPS
MaintenanceManually switch to bypass source to avoid downtime during service maintenance.
Availability
Delta Confidential
Dual Input Design andRedundant Aux. Power
10
Dual input design to allow input from 2 different sources of power supply for higher availability
Redundant auxiliary power to deliver high system reliability
Single Aux. Power failure won’t affect the output load.
Availability
Delta Confidential
User Benefits
1111
PowerPerformance& Efficiency
Availability
Flexibility Manageability
Delta Confidential
Excellent Operating Efficiency
12
One of the most energy-efficient UPS in its class AC-AC efficiency up to 96% ECO mode efficiency up to 99% The significant savings in operational costs
PowerPerformance& Efficiency
100,000 €
110,000 €
120,000 €
130,000 €
140,000 €
150,000 €
160,000 €
170,000 €
180,000 €
Altron HPH Legacy UPS
Power consumption comparison
UltronHPH
Legacy UPS
Power provided during day 30 30,00 kWAdditional losses as efficiency difference 0% 4%Total consumption increased by losses 30 31,25 kWDay consumption, considered 14 hours 420 437 kWh
Power provided During night ....50% 15 15 kWAdditional losses by efficiency diff.erence 0% 6%Total consumption increased by losses 15 15,96 kWNight consumption considered 10 hours 150 159,57 kWh
Total (day + night) consumption 570 597 kWYearly consumption - per 360 Days 205.200 214.947 kWLifetime consumption per 8 years 1.641.600 1.719.574 kWhLifetime Bill for Power 0,1EUR/kWh 164.160 171.957 EURPower saving per 8 years operation 77.974 kWhMoney saving per 8 years operation 7.797 EUR
Delta Confidential13
PF = 1 PF = 0.9 PF = 0.8
40KW 36KW 32KW
40kVA 40kVA 40kVA
11% less25% less
Noderating
No derating with any loads (leading or lagging). Permanent 100% kW. No over-sized UPS for any loads. More output power than legacy UPS. High inverter reliability to support full power to any loads.
UPS A UPS BDelta Ultron HPH
Output Power Factor = 1 kVA=KW Power
Performance& Efficiency
Delta Confidential14
Lower Harmonic Distortion
THDv
Optimal generator size can be chosen
Initial investment cost and installation cost can be reduced
THDi
THDi <3%
Better power quality Less heat to prevent low performance
and short life of load
THDv <2%
Optimize generator sizing & mains
transformer
Low pollution (iTHD < 3%) to upstream power
Lower THDvfor better power quality
PowerPerformance& Efficiency
Delta Confidential15
Smaller Footprint for longerbackup application
Smaller footprint than competitor’s products Better space utilization and saved space for revenue-
producing equipment
Dimensions (mm) Footprint(mm2)H W D
Delta UltronHPH 800 380 800 304,000
Competitor A 1400 600 825 495,000
Competitor B 1490 523 838 438,300
Competitor C 823 523 854 446,600
30/40kW configuration
PowerPerformance& Efficiency
Delta Confidential16
Intelligent Fan Speed Controland Failure Detection
3 stages of fan speed control to maximize efficiency and significantly reduce audible noise
Automatically adjusts the fan speed based on the change of load percentage
Fan failure detection and easy replacement design to simplify the maintenance process and reduce MTTR
Load 0% 40% 70% 100%
Slow Fast Fan Speed
PowerPerformance& Efficiency
Delta Confidential
User Benefits
1717
Flexibility
AvailabilityPower
Performance& Efficiency
Manageability
Delta Confidential
Parallel Expansion
18
Parallel expansion without extra hardware allows quick capacityupgrades to meet business growth.
Add more UPSs when more facilities are expanded.
Parallel Expansion Up to 4 units
Maximum Capacity = 160KW
Loads Loads Loads
Flexibility
Delta Confidential19
A Wide Choice of Configurations
Stand Alone
N+X redundancy
Load
Up to 4 units in a parallel configuration to provide redundancy for reliability
Load
Hot Stand-By
Load
Normal mains
By pass mains
Flexibility
Delta Confidential
User Benefits
2020
Manageability
AvailabilityPower
Performance& Efficiency
Flexibility
Delta Confidential
• Flexible length of string enable optimal battery selection• Battery remaining capacity displayed in percentage• Over charge protection• Deep discharge protection• Float/boost stage charge• Auto/manual battery test• Battery remaining capacity warning• Battery reverse detection• Compatibility with the SMF/VRLA/Ni-Cd/LATB batteries
Intelligent Battery Management
21
Prevents battery from overcharge and deep discharge situations to sustain battery lifespan.
Manageability
Delta Confidential22
Intelligent Battery Management
Adjustable charging currentEven at full load conditions, Ultron HPH offers up to 9A charging current for 40kW model and 5A for 20/30kW model. Optionaly 9A.
Flexible battery voltage Adjustable battery voltage range 456V~504V and charging voltage from 254V to 291V adapt to different types of batteries
Flexible arrangement of battery quantityChangeable battery quantity from 36 to 42 pcsto optimize battery investment
9A Max. charging capability: 9A
5A1
2
3
Manageability
Delta Confidential
50%SpaceSaving
Batterycabinet #1
23
Common Battery Configuration
Customers can save installation space and reduce battery cost via common battery configuration in parallel mode.
Save 50% Space!!
Manageability
Batterycabinet #2
Delta Confidential24
Mini Slot Provides the cost-effective
alternative for multiple mini-size cards such as Mini SNMP, Mini Relay I/O, Mini USB, Mini ModBus or Mini TVSS cards.
SNMP IPv4, IPv6 Card Monitors and controls the status of
the UPS via a network system. The SNMP IPv6 version adds the
security protocols to response requirements, and it is the next generation of internet protocol standard.
ModBus CardProvides continuous and reliable remote monitoring of a UPS system through Industrial Automation System (IAS) and Building Management System.
Relay I/O CardIncreases the quantity of dry contacts.
Smart Slot Accepts multiple communications cards
1 2
1
2
Connectivity & Manageability
Ultron HPH 20 kW Rear View
Manageability
Delta Confidential25
RS232 PortConnects the UPS to a computer
Parallel PortsFor UPS parallelcommunication
REPOFor remote emergency shutdown
Charger Detection PortTo connect with an external charger box
Output / Input Dry Contacts Provides 6 sets of programmable output
dry contacts for receiving UPS events Provides 2 sets of input dry contacts
1 3
4
5 6
Connectivity & Manageability
2
Parallel SwitchActivates UPS parallel function
Ultron HPH 20 kW Rear View
Manageability
Delta Confidential26
• Insight Power ManagerCentralized monitoring system over networks.
• UPSentry 2012Communicates with UPS through RS232 and USB for UPS managementWorks with ShutdownAgent to protect a group of PCs, workstations or servers
• Webserver on SNMP card IPv4• Advanced web server monitoring on SNMPcard IPv
• ShutdownAgent 2012Cooperates with SNMP card or UPSentry 2012 to shutdown multi-servers in various operating systems and virtual machine gracefully to prevent possible data corruption
Management Software
NetworkSerial
UPSentry 2012
ShutdownAgent2012
HUB
ShutdownAgent2012
ShutdownAgent2012
InsightPowerSNMP card
Manageability
Delta Confidential27
Control and Display Panel
Excellent local communications through LCD panel
Power On /Off Keys
Online/Battery/Bypass Mode / Fault LED Indicator
Function keys
EPO Key
This LCD panel displays the operating status of the UPS and the relevant monitoring data.
Manageability
Delta Confidential
Why Ultron HPH Series?
AvailabilityAvailability
• Wide input voltage tolerance
• DSP design• High overload
protection• Dual input
• Redundant Aux. power
• In-built manual bypass
FlexibilityFlexibility
• A wide choice of configurations:N+X redundancy, stand alone, hot stand-by,and more.
• Parallel expansion up to 4 units
• O/P PF = 1• THDi<3% ; THDv<2%• AC-AC efficiency
up to 96%
• ECO mode efficiency up to 99%
• Small footprint
Power Performance &
Efficiency
Power Performance &
Efficiency
28
Best-in-class performance
and power protection for
mission critical applications
ManageabilityManageability
• Multi-connectivity interface
• Advanced UPS management & software
• Intelligent battery management
• Common battery configuration