user guide deviweb™ - danfoss€¦ · devi lit. ff 3 user guide deviweb™ 1 functions 1.1 home...

36
1 DEVI Lit. № User Guide DEVIweb™ User guide DEVIweb™ Heating systems control from everywhere Intelligent solutions with lasting effect Visit devi.com DEVIweb™

Upload: others

Post on 10-Mar-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

1DEVI Lit. №

User Guide DEVIweb™

User guide

DEVIweb™Heating systems control from everywhere

Intelligent solutions with lasting effect

Visit devi.com

DEVIweb™

Page 2: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

DEVI Lit. №2

User Guide DEVIweb™

Table of Contents

1 FUNCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.1 Home mode (Comfort) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.2 Away mode (Economy). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.3 Manual mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.4 Pause mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.5 Lock screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41.6 Weekly schedule. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41.7 Regulation type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51.8 Sensor type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61.9 Flooring type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61.10 Minimum floor temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61.11 Maximum floor temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61.12 Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71.13 Frost protection temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71.14 Mobile app DEVIweb™ Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71.15 Wi-Fi configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

2 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92.1 DEVIreg™ SMART INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92.2 DEVIweb™ settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

2.2.1 Sign in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92.2.2 Adding Facility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92.2.3 Edit facility settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112.2.4 Users . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112.2.5 Wi-Fi networks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112.2.6 Use profiles - Thermostats. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .132.2.7 Installation profiles - Thermostats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .152.2.8 Use profiles - Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .192.2.9 Installation profiles - Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .212.2.10 Location configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .232.2.11 Sub-location configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .242.2.12 Adding of thermostats or switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26

2.3 DEVIweb™ Tool settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .282.3.1 Setup mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .282.3.2 DEVIweb™ Tool installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29

Page 3: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

3DEVI Lit. №

User Guide DEVIweb™

1 FUNCTIONS

1.1 Home mode (Comfort)

Comfort set-point is for room that is actively used.

Minimum set-point value is 5 °C; maximum value is 35 °C and 45 °C depends on break-out function.

Set-point resolution is 0.5 °C.

Home: 21.0°

1.2 Away mode (Economy)

Economy set-point is for room that is temporarily not used. For example, when people are at work, at school or during night when user is sleeping.

Minimum set-point value is 5 °C; maximum value is 35 °C and 45 °C depends on break-out function.

Set-point resolution is 0.5 °C.

Away: 17.0°

1.3 Manual mode

When user changes temperature or On/Off state from the display of DEVIreg Smart following symbol will appear:

1.4 Pause mode

The user is able to turn off the heating control from the DEVIweb™.

In “Pause mode” state:

• Temperature is not maintained

• Connection keeps the previous state

The thermostat/switch will remain in heating control OFF state until the user leaves the state. User is able to leave the heating control OFF state from local UI. When user leaves the state, it goes into AP mode for 2 minutes and then the previously active operational state is restored.

Pause:

Page 4: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

DEVI Lit. №4

User Guide DEVIweb™

1.5 Lock screen

Safety lock is for avoiding unintentional changes in thermostat/switch settings from local User Interface.

It must not be possible to make changes to settings from local User Interface when safety lock is on. Local User Interface must indicate when safety lock is on and attempt is made to change thermostat’s/switch’s settings or state from local User Interface.

When safety lock is on, touching the display, the up and down arrows will blink 3 times. This is how user will know that safety lock is on.

Screen lock: On O�

1.6 Weekly schedule

The user can choose weekly schedule. Weekly schedule maintains the temperature by timer.

The user must be able to set time and temperature settings from web application DEVIweb™.

The user is able to configure from web application DEVIweb™:

• Different schedule for each weekday.

• Two different Comfort periods per weekday.

• The schedule with resolution of 30 minutes.

• Comfort state set-point for the whole week.

• Economy state set-point for the whole week.

• To activate Comfort state.

• To activate Economy state.

Page 5: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

5DEVI Lit. №

User Guide DEVIweb™

Schedule

Monday:

Tuesday:

Wednesday:

Thursday:

Friday:

Saturday:

Screen lock:

6.00 - 9.30 15.00 - 22.30

6.00 - 9.30 15.00 - 22.30

6.00 - 9.30 15.00 - 22.30

6.00 - 9.30 15.00 - 22.30

6.00 - 9.30 15.00 - 22.30

6.00 - 9.30 15.00 - 22.30

6.00 - 9.30 15.00 - 22.30

1.7 Regulation type

The user can choose three types of regulation:

• Room

• Floor

• Floor and Room

Regulation Room

Floor

FloorAndRoom

Page 6: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

DEVI Lit. №6

User Guide DEVIweb™

1.8 Sensor type

The user can choose different types of floor sensor: NTC 15 kΩ @ 25°C, 3 m. (default), NTC 6,8 kΩ @ 25°C, NTC 10 kΩ @ 25°C, NTC 12 kΩ @ 25°C, NTC 33 kΩ @ 25°C, NTC 47 kΩ @ 25°C.

Sensor Type Devi15K

1.9 Flooring type

The user can choose different types of floor surface: Tiles, Hardwood, Laminate, Carpet.

Flooring Tiles

Hardwood

Laminate

Carpet

1.10 Minimum floor temperature

Minimum floor temperature set-point is for maintaining the minimum floor temperature.

It is possible to enable/disable and change the minimum floor temperature set-point from the web ap-plication DEVIweb™.

Minimum set-point value is 5 °C, maximum value is 35 °C and 45 °C depends on break-out function.

Set-point resolution is 0.5 °C.

Minimum �oor temperature 8.0°

1.11 Maximum floor temperature

Maximum floor temperature set-point is used to specify a maximum temperature for the floor.

Minimum set-point value is 25 °C, maximum and default value is 35 °C and 45 °C depends on break-out function.

Set-point resolution is 0.5 °C

Maximum �oor temperature 28.0°

Page 7: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

7DEVI Lit. №

User Guide DEVIweb™

1.12 Output

Output. Energy output from 100W to 3675W in steps of 25W. “External relay” when using external relay and “--” when the power is unknown.

OutputNotice: If greather than 3675W use a contactor 100W

1.13 Frost protection temperature

The user can enter and leave frost protection state from the web application DEVIweb™.

Frost protection state is similar to heating control OFF state, but in this state minimal temperature set-point is maintained.

The user can configure the frost protection set-point from the web application DEVIweb™.

Value range is 5 °C - 9 °C with resolution of 0.5 °C.

Frost protection temperature 5.0°

1.14 Mobile app DEVIweb™ Tool

DEVIweb™ Tool is designed to connect Location / Sub-Location with installed thermostat/switch and add a it to the control system DEVIweb™.

1.15 Wi-Fi configuration

Currently a DEVIreg™ Smart thermostat/switch can only store one Wi-Fi configuration (SSID+PASSWORD). In order to prevent that the installer must re-configure all DEVIreg™ Smart thermostats/switches when the Wi-Fi password change, the DEVIreg™ Smart thermostat/switch needs to be able to store a list of up to five Wi-Fi configurations. If the DEVIreg™ Smart thermostat/switch fails to connect to one Wi-Fi (both SSID and password required to make it unique), it should try the next.

Page 8: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

DEVI Lit. №8

User Guide DEVIweb™

Name

SSID Technical support

Password

Wi-Fi

Page 9: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

9DEVI Lit. №

User Guide DEVIweb™

2 INSTALLATION

2.1 DEVIreg™ SMART INSTALLATION

Use Installation Guide to install DEVIreg™ Smart thermostat/switch firstly.

2.2 DEVIweb™ settings

2.2.1 Sign in

Login to http://www.deviweb.danfoss.com with a valid username and password. Enter given User name and Password and press on Sign in button:

2.2.2 Adding Facility

Click on the marked button:

Click on Add Facility, fill in all necessary information about your facility and press on Save:

Page 10: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

DEVI Lit. №10

User Guide DEVIweb™

Name

Address

City

State/Province/Region

Zip/Post Code

Country Please select an option

Phone Number

*Important: When you name the facility press

Page 11: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

11DEVI Lit. №

User Guide DEVIweb™

2.2.3 Edit facility settings

Go back to the main Menu by clicking on Close facility management and press on Edit facility settings button:

2.2.4 Users

In this section can be added additional users with different roles: User and Administrator.

Owner has full access.

Administrator has full access, but only to specific facilities.

User has access to specific facilities, but only to daily profiles and main screen. Can not access installation profiles & create users.

Fill in all parameters on the screen and press on Save button:

*Important: When you name the user press

Page 12: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

DEVI Lit. №12

User Guide DEVIweb™

2.2.5 Wi-Fi networks

In this section should be added information about Wi-Fi network. The DEVIreg™ Smart can hold up to 3 Wi-Fi networks. Click on the Wi-Fi networks and press Add Wi-Fi button.

Fill in all parameters on the screen and press on Save button:

*Important: When you name the network press

Name

SSID Technical support

Password

Wi-Fi

Page 13: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

13DEVI Lit. №

User Guide DEVIweb™

You will see the list of all Wi-Fi networks on the screen below:

2.2.6 Use profiles - Thermostats

In this section can be created different templates of daily use settings for thermostats: Comfort tem-perature, Economy temperature, Pause mode, Lock screen, Schedule. The purpose of creating different templates of the settings is easiness of changing many settings at the same time. When changed centrally - the changes will be reflected on all locations setup with this profile. Press on Add Profile button:

And fill in all parameters which are shown on the screen below and Save:

*Important: When you name the profile press

Page 14: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

DEVI Lit. №14

User Guide DEVIweb™

Name

Home: 21.0°

Away: 17.0°

Pause: On O�

Lock screen: On O�

Schedule

Monday:

Tuesday:

Wednesday:

Thursday:

Friday:

Saturday:

Screen lock:

6.00 - 9.30 15.00 - 22.30

6.00 - 9.30 15.00 - 22.30

6.00 - 9.30 15.00 - 22.30

6.00 - 9.30 15.00 - 22.30

6.00 - 9.30 15.00 - 22.30

6.00 - 9.30 15.00 - 22.30

6.00 - 9.30 15.00 - 22.30

Page 15: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

15DEVI Lit. №

User Guide DEVIweb™

You will see the list of all Use profiles on the screen below:

2.2.7 Installation profiles - Thermostats

In this section can be adjusted thermostat settings for Regulation type, Sensor type, Flooring type, Mini-mum floor temperature, Maximum floor temperature, Output and Frost protection temperature.

The purpose of creating different templates of the settings is easiness of changing many settings at the same time. When changed centrally - the changes will be reflected on all locations setup with this profile.

Press Add Profile button.

Fill in all parameters on the screen and press on Save button:

*Important: When you name the profile press

Page 16: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

DEVI Lit. №16

User Guide DEVIweb™

3 regulation types can be chosen

Room, Floor and Floor&Room depends on the application.

Name

OutputNotice: If greather than 3675W use a contactor 0W

Frost protection temperature 5.0°

Country Room

Page 17: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

17DEVI Lit. №

User Guide DEVIweb™

Name

OutputNotice: If greather than 3675W use a contactor 0W

Frost protection temperature 5.0°

Flooring Laminate

Maximum �oor temperature 28.0°

Sensor Type Devi15K

Regulation Floor

Minimum �oor temperature 8.0°

Page 18: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

DEVI Lit. №18

User Guide DEVIweb™

Name

OutputNotice: If greather than 3675W use a contactor 0W

Frost protection temperature 5.0°

Flooring Laminate

Maximum �oor temperature 28.0°

Sensor Type Devi15K

Regulation FloorAndRoom

Minimum �oor temperature 8.0°

You will see the list of all Installation profiles on the screen below:

Page 19: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

19DEVI Lit. №

User Guide DEVIweb™

2.2.8 Use profiles - Switches

In this section can be created different templates of daily use settings for switches: Lock screen and Schedule. The purpose of creating different templates of the settings is easiness of changing many set-tings at the same time. When changed centrally - the changes will be reflected on all locations setup with this profile. Press on Add Profile button:

And fill in all parameters which are shown on the screen below and Save:

*Important: When you name the profile press

Page 20: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

DEVI Lit. №20

User Guide DEVIweb™

Name

Lock screen: On O�

Schedule

Monday:

Tuesday:

Wednesday:

Thursday:

Friday:

Saturday:

Screen lock:

6.00 - 9.30 15.00 - 22.30

6.00 - 9.30 15.00 - 22.30

6.00 - 9.30 15.00 - 22.30

6.00 - 9.30 15.00 - 22.30

6.00 - 9.30 15.00 - 22.30

6.00 - 9.30 15.00 - 22.30

6.00 - 9.30 15.00 - 22.30

Page 21: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

21DEVI Lit. №

User Guide DEVIweb™

In order to turn On/Off the equipment use schedule or buttons on switch display.

Page 22: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

DEVI Lit. №22

User Guide DEVIweb™

You will see the list of all Use profiles on the screen below:

2.2.9 Installation profiles - Switches

In this section can be adjusted switch settings for Output of On/Off equipment. The purpose of creating different templates of the settings is easiness of changing many settings at the same time. When changed centrally - the changes will be reflected on all locations setup with this profile. Press Add Profile button.

Fill in all parameters on the screen and press on Save button:

*Important: When you name the profile press

Page 23: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

23DEVI Lit. №

User Guide DEVIweb™

Name

OutputNotice: If greather than 3675W use a contactor 0W

You will see the list of all Installation profiles on the screen below:

Page 24: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

DEVI Lit. №24

User Guide DEVIweb™

2.2.10 Location configurations

Go back to the main Menu and press Add location button.

The term Location is related to a Facility and could be e.g. a floor/apartment/room. Name the Location (e.g. floor or room) in your facility. Select type – Grouping, choose Wi-Fi network and click on Save button.

Using Grouping type the groups of rooms, floors, buildings, etc. can be created.

Name

Location

TypeTyyypppe

Vejle house

Grouping

ThermostatSwitch

Name

Wi-Fi network: Wi-Fi IOTWi-Fi

Con�gurations

*Important: When you name the Location press

Page 25: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

25DEVI Lit. №

User Guide DEVIweb™

You will see the list of all Locations on the screen below:

2.2.11 Sub-location configurations

Go back to the main Menu press button and click on Create sublocation. Name the sub-location (e.g. Room 1), choose the location of this sub-location (Room 1 on First floor), select type – Grouping, select Wi-Fi network and press Save button.

Page 26: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

DEVI Lit. №26

User Guide DEVIweb™

Name

LocationLocation

Room 1

Vejle houseFirst �oorGround �oor

Name

Location

Type

Ground �oor

Room 1

Grouping

Name

Wi-Fi network: Wi-Fi IOTWi-Fi

Con�gurations

You will see the list of all locations and sub-locations on the screen below:

Page 27: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

27DEVI Lit. №

User Guide DEVIweb™

2.2.12 Adding of thermostats or switches

Press on Add location button or press button and click on Create sublocation, choose the

location for thermostat or switch, select Type for Thermostat or Switch and set up all configurations ac-cording previous paragraphs.

Name

TypeTyyypppe

Bathroom

Grouping

ThermostatSwitch

Location

Room 1

Select suitable configuration from the drop-down list for each parameter. All drop-down lists consist of already prepared configurations from the previous paragraphs.

Page 28: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

DEVI Lit. №28

User Guide DEVIweb™

Name

Location

Vejle house

Type

Thermostat

Installation pro�le: Please select an option

Con�gurationsUse pro�le

Wi-Fi network: Please select an option

You will see the list of all thermostats/switches on the screen below:

Page 29: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

29DEVI Lit. №

User Guide DEVIweb™

Serial number

PeerId �06933320ad0526eac20ac734526f65c6cf63d32994f0068fc427e2fb5666014

10032562

f0:c7:7f:6d:92:bf

3.1

0.33kWh

2.12kWh

14.98kWh

24 °C

18 °C

6 °C

22 °C

18 °C

No

No

WeeklyComfort

Floor

24/09/2019 16:32:42

Cancel Save

Information

Consumption

Setpoints

Temperatures

Settings

Mac address

Hardware revision

Last 7 days

Last 30 days

All time

At home

Away

Frost protection

Temporary

Floor

Is breakout

Open window detection

Mode

Regulation

Last seen

Use profile Configurations Device

Page 30: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

DEVI Lit. №30

User Guide DEVIweb™

2.3 DEVIweb™ Tool settings

DEVIweb™ Tool is designed to connect Location / Sub-Location with installed thermostats/switches and add a it to the control system DEVIweb™.

2.3.1 Setup mode

Open web application DEVIweb™ and press Edit facility settings.

Switch ON Setup mode and press on the Installer code button:

Send Installer code via email or just dictate this code to installer. The setup mode is active in 48 hours.

Page 31: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

31DEVI Lit. №

User Guide DEVIweb™

Setup mode activated

Send invite

Installer code JOGB5OLB

8/9/2019Expires

Send link to installer

[email protected]

Invited installers

2.3.2 DEVIweb™ Tool installation

Log in to Google Play and download the mobile app DEVIweb™ Tool that is used to set up a Facility. For now, only available on Google Play.

When you open the mobile app DEVIweb™ Tool and you have not yet created my profile (name, com-pany, phone and email) you are prompted to do so. All details are mandatory. The profile is stored locally on the device.

Page 32: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

DEVI Lit. №32

User Guide DEVIweb™

Name

Company

Phone

Email

CONFIRM

Enter Installer code from web application DEVIweb™. And press Next.

CONFIGURE

G5BBP2UC

NEXT

FacilityLocationsLocation con�gurationsSchedule con�gurationsThermostat con�gurationsWiFi con�gurations

Page 33: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

33DEVI Lit. №

User Guide DEVIweb™

Choose the Location, Sublocation where was installed the DEVIreg™ Smart thermostat/switch.

Test hotelKhvoiky

First �oor

Ground �oor

Ground �oor

Bathroom

Confirm all configurations for chosen thermostat/switch.

Con�rm

Please con�rm the followingsettings are correct:

WiFi SSIDRegulationSensorFlooringOutput

FloorrAAnndRoomDeevvi15K

Tilleess700 W

Con�rm

Please con�rm the followingsettings are correct:

WiFi SSIDOutput

IOT100 W

Go to the thermostat/switch with mobile phone and follow the on-screen instructions.

Page 34: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

DEVI Lit. №34

User Guide DEVIweb™

Press the green pulsating buttonon the thermostat to con�rm the

connection

The mobile app DEVIweb™ Tool looks for a DEVIreg™ Smart thermostat/switch in AP mode and when one is found, the mobile app DEVIweb™ Tool connects to it and transfers the Configuration that is defined on the selected Location. The mobile DEVIweb™ Tool confirms that linking is completed and discon-nects from the DEVIreg™ Smart thermostat/switch. The list of DEVIreg™ Smart thermostats/switchs on the selected Location is updated.

Page 35: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

35DEVI Lit. №

User Guide DEVIweb™

Page 36: User Guide DEVIweb™ - Danfoss€¦ · DEVI Lit. ff 3 User Guide DEVIweb™ 1 FUNCTIONS 1.1 Home mode (Comfort) Comfort set-point is for room that is actively used. Minimum set-point

User Guide DEVIweb™

BC318949874182en-000101 Danfoss © | FEC | 2019.09