Page 1: User Instruction Manual - Interact | Vanderbilt · 16mm Installation Procedure Step by Step align the door drill template on the door. Use a spindle inserted through the mortise lock

User Instruction Manual

Ref: 18-00087

Page 2: User Instruction Manual - Interact | Vanderbilt · 16mm Installation Procedure Step by Step align the door drill template on the door. Use a spindle inserted through the mortise lock

This insTallaTiOn guide cOvers The fOllOwing prOducTs:

acTpro elock ACTpro eLock 125Khz RFID

acTpro elock K ACTpro eLock 125Khz RFID with external Key Override

acTpro elock K2 ACTpro eLock 125Khz RFID with internal & external Key Override

acTpro elock Mf ACTpro eLock MIFARE Classic/DESFire EV1

acTpro elock MfK ACTpro eLock MIFARE Classic/DESFire EV1 with external Key Override

acTpro elock MfK2 ACTpro eLock MIFARE Classic/DESFire EV1 with internal & external Key Override

carTOn cOnTenTs:

1. User Installation Manual (this document)

2. Front and Back escutcheons including 8mm spindle

3. Door drill template

4. 2 x Door handles and handle grub screws

5. 2 x 35mm and 2 x 45mm M5 Mounting screws

6. 2 x M3 6mm back cover fixing screws.

7. Screw cap cover

8. 2.5mm Hex Key

9. CR123A Battery

TOOls reQuired:

1. Power drill

2. Drill bits 16mm and 8mm

3. Pozi screwdriver

4. Hex key 2.5mm (Supplied)

5. Thread locking adhesive

(ACT recommends Loctite 242).

The ACTpro eLock can be used on most mortise locks with 8mm spindle and is compatible with door thicknesses from 36mm to 60mm.

The ACTpro eLock K and MFK versions support euro profile cylinder locks that are positioned 72mm from the spindle centre; and has key override cut-out on the entry escutcheon only.

The ACTpro eLock K2 and MFK2 versions of the eLock support euro profile cylinder locks that are positioned 72mm from the spindle centre; and has key override cut-out on the entry and exit escutcheon.

wireless cOMMunicaTiOns:

The ACTpro eLock and the eLock Hub communicate

wirelessly, operating at 868.8MHz. The communications

between the eLock and hub are secured using 128 bit

AES encryption.

The range of the wireless signal is dependent on the

characteristics of the building and it is recommended to

complete a site survey to determine the best location of

ACTpro eLock hubs.

Page 3: User Instruction Manual - Interact | Vanderbilt · 16mm Installation Procedure Step by Step align the door drill template on the door. Use a spindle inserted through the mortise lock

OperaTiOn:

When a valid card is presented to the eLock, the LED will flash

green and the door will unlock.

If an invalid card is presented, the LED will flash red and the

door will remain locked.

Make sure cards and fobs are placed accurately over the card

read area on the ACTpro eLock. This is the area indicated by

the card logo on the front escutcheon.

dOOr MOniTOring:

ACT supplies a door monitoring kit (order code ACTpro eLock

DM), which allows the door position to be monitored.

Wire the kit to the DOOR AJAR terminals on the ACTpro

eLock

BaTTery:

A low battery condition will be reported to the ACTenterprise

software. The ACTpro eLock will still continue to operate but

the battery should be replaced as soon as possible.

If the battery is completely flat, the ACTpro eLock can be

powered via the USB connector using a laptop or other USB

power source. Once the ACTpro eLock is powered over the

USB, presenting a valid card will unlock the door.

Depending on use, the battery can last up to 200,000

activations or 5 years.

cerTificaTiOn:

ACT declares that this equipment fulfils the requirements

of EU EMC directive 2004/108/EC.

envirOnMenT:

Temperature: -10°C/+50°C

ip rating: IP 55 - Not recommended for external use.

Page 4: User Instruction Manual - Interact | Vanderbilt · 16mm Installation Procedure Step by Step align the door drill template on the door. Use a spindle inserted through the mortise lock

16mm

Installation Procedure Step by Step

align the door drill template on the door. Use a spindle inserted through

the mortise lock to position the template correctly.

drill the top hole using a 16mm bit. Drill the hole at the bottom using an 8mm drill bit, drilling halfway from either side of the door. (Top hole needs to be larger to accommodate the eLock cable).Mark the drill points on both sides of the door.

1

2 3

Page 5: User Instruction Manual - Interact | Vanderbilt · 16mm Installation Procedure Step by Step align the door drill template on the door. Use a spindle inserted through the mortise lock

fit the back escutcheon and spindle through the mortise lock. Thread the cable through hole at the top of the back escutcheon. Push the spindle through the front escutcheon.

Thread the cable from the front escutcheon through the top hole in the door. Do not force the cable or use a sharp instrument to pass it through the door.

5

6

4

Ensure that the unit is aligned correctly. screw the units together tightly. Ensure the cable is not trapped.

Page 6: User Instruction Manual - Interact | Vanderbilt · 16mm Installation Procedure Step by Step align the door drill template on the door. Use a spindle inserted through the mortise lock

To default the ACTpro elock, insert battery and then hold down the tamper switch and recessed button until the unit beeps and the LED flashes.

insert the battery. The ACTpro eLock must only be used with ACT supplied batteries. Note: Use of non-ACT supplied batteries will invalidate the ACT warranty.

7 8

9

plug in the ribbon cable connector. Note: Polarised guide on the ribbon cable connector is on the right.

Page 7: User Instruction Manual - Interact | Vanderbilt · 16mm Installation Procedure Step by Step align the door drill template on the door. Use a spindle inserted through the mortise lock

Apply thread locking adhesive to the handle grub screws and fix handles securely.

place the cover on unit. Screw the cover at the places indicated. The bottom screw should be inserted first. Clip on the screw cap cover.

Peel off the protective cover.

10

11 12

Page 8: User Instruction Manual - Interact | Vanderbilt · 16mm Installation Procedure Step by Step align the door drill template on the door. Use a spindle inserted through the mortise lock

Ireland Office

Unit C1, South City Business Park

Tallaght, Dublin 24

United Kingdom Office

4 Millennium House, Priestly Rd

Basingstoke, Hampshire, RG24 9NP

UK Lo-call 0845 300 5204

International +353 1 466 2570

Email [email protected]

www.accesscontroltechnology.com

Job No: 014ACT2014