user instructions scissorsafe fall arrest...

9
Scissorsafe Anchorage System - User Instruc6ons – fall arrest July 2016 Information resource www.scissorsafe.co.uk Contact [email protected] User Instructions Scissorsafe Fall Arrest System

Upload: truongtruc

Post on 05-Jun-2018

263 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: User Instructions Scissorsafe Fall Arrest originalscissorsafe.co.uk/.../User-Instructions_Scissorsafe_Fall-Arrest.pdf · User Instructions Scissorsafe Fall Arrest ... User Instructions

ScissorsafeAnchorageSystem-UserInstruc6ons–fallarrestJuly2016

Information resource [email protected]

User Instructions

Scissorsafe Fall Arrest System

Page 2: User Instructions Scissorsafe Fall Arrest originalscissorsafe.co.uk/.../User-Instructions_Scissorsafe_Fall-Arrest.pdf · User Instructions Scissorsafe Fall Arrest ... User Instructions

Index

2  Index and Contact details3  Product description & safety considerations4  Components for Fall Arrest5  Void formers for Fall Arrest6  Void former positions7  Installing the Scissorsafe anchorage system8  Correct and incorrect installation9  9 Notes

Page 3: User Instructions Scissorsafe Fall Arrest originalscissorsafe.co.uk/.../User-Instructions_Scissorsafe_Fall-Arrest.pdf · User Instructions Scissorsafe Fall Arrest ... User Instructions
Page 4: User Instructions Scissorsafe Fall Arrest originalscissorsafe.co.uk/.../User-Instructions_Scissorsafe_Fall-Arrest.pdf · User Instructions Scissorsafe Fall Arrest ... User Instructions

Scissorsafe fall arrest components

SCS003 SCISSORSAFE ANCHORAGE TOOL

SCS005 10mm KARABINER

SCS008 SAFETY HARNESS & HARNESS TAIL

SCS045 – SCS012 SELD RETRACTING LIFELINE

Page 5: User Instructions Scissorsafe Fall Arrest originalscissorsafe.co.uk/.../User-Instructions_Scissorsafe_Fall-Arrest.pdf · User Instructions Scissorsafe Fall Arrest ... User Instructions

User Instructions Void Former Positions for Fall Arrest

Before installing Scissorsafe expendable insert moulds into the formwork, carefully plan their positions, avoiding placement too close to concrete edges or joints or into concrete thicknesses less than 170mm.

ScissorsafeAnchorageSystem-UserInstruc6ons–PlacingmouldsinformworkJanuary2013

To minimise the risk of injury Anchorages should be positioned as vertically as possible above the intended work area in an arc no more than thirty degrees from vertical so as to prevent in the event of a fall the user from swinging dangerously to and fro. ( commonly known as Pendulum or Swing Fall )

A Fall Arrest system provides maximum freedom of movement for workers to conduct their duties. In doing so it allows them to reach the point where a fall could occur, However, in the event of a fall, the fall will be arrested and so allow the person to be rescued.

Component Key & Schedule

Pt 1 SCS002 Scissorsafe Two Part Cast-In FormerPt 2 SCS003 Scissorsafe Anchorage ToolPt 3 SCS050 Self Retracting Lifeline Pt 4 SCS020 Two Point Body Harness

11

2

3

4

Information resource [email protected]

Page 6: User Instructions Scissorsafe Fall Arrest originalscissorsafe.co.uk/.../User-Instructions_Scissorsafe_Fall-Arrest.pdf · User Instructions Scissorsafe Fall Arrest ... User Instructions

User Instructions Void Former Positions for Fall Arrest

ScissorsafeAnchorageSystem-UserInstruc6ons–PlacingmouldsinformworkJanuary2013

ABCDFLOORHEIGHTLINELENGTHHORDISTANCEFROMANCHORHORDISTANCEFROMANCHORAT30degINONEDIRECTIONINBOTHDIRECTIONS2.5mtr2.9mtr1.4mtr2.8mtr3.0mtr3.5mtr1.7mtr3.4mtr3.5mtr4.0mtr2.0mtr4.0mtr4.0mtr4.6mtr2.3mtr4.6mtr

Information resource [email protected]

Page 7: User Instructions Scissorsafe Fall Arrest originalscissorsafe.co.uk/.../User-Instructions_Scissorsafe_Fall-Arrest.pdf · User Instructions Scissorsafe Fall Arrest ... User Instructions

Installing the Scissorsafe Anchorage System

In Fall Arrest configuration the Void Formers are cast at regular spacings around the perimeter and leading edges of the structure, anywhere where an operative may need to wear Personal Protective Equipment.

Void Former distances are determined by assessing the ceiling height and calculating the horizontal distance from it no greater than 30 degrees.

An operative that strays beyond 30 degrees from the overhead anchorage is vulnerable to the potential of Pendulum Swing in the event of a fall occurence.

Nailing disk removal and anchorage tool insertion

Page 8: User Instructions Scissorsafe Fall Arrest originalscissorsafe.co.uk/.../User-Instructions_Scissorsafe_Fall-Arrest.pdf · User Instructions Scissorsafe Fall Arrest ... User Instructions

Correct scissorsafe connection

Incorrect scissorsafe connection

Page 9: User Instructions Scissorsafe Fall Arrest originalscissorsafe.co.uk/.../User-Instructions_Scissorsafe_Fall-Arrest.pdf · User Instructions Scissorsafe Fall Arrest ... User Instructions