usf folder english fin2 · pre-treatment: only purified water can be clean water 03 filters: l...

8
www.usf-water.com EN Pharmaceutical industry

Upload: others

Post on 15-Aug-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: USF Folder english FIN2 · Pre-Treatment: Only purified water can be clean water 03 FILTERS: L Cartridge filtration: various filter types pos- sible, string wound filters, pleated

www.usf-water.com E N

Pharmaceuticalindustry

Page 2: USF Folder english FIN2 · Pre-Treatment: Only purified water can be clean water 03 FILTERS: L Cartridge filtration: various filter types pos- sible, string wound filters, pleated

02

How the system components and pipelines must be const-

ructed, which materials are used to ensure the quality of the

water for the production of medicines, ointments or even

decorative cosmetics – all this is subject to strict conditions.

In addition to complying with exacting legal requirements,

our purified water system fulfil the highest customer re-

quirements due to the core technology of Ionpure-CEDI®

modules. They stand for quality, safety, profitability and a long

service life. International companies in the pharmaceutical

and cosmetics industry have known this for a long time, and

have been using our solutions for years.The world of USF Water PurificationW E C OV E R A L A RG E S P E C T RU M . And as with

all solutions to be optimally adapted, we adapt our

products optimally to fulfil your requirements. From

pre-treatment over production to storage and distribu-

tion, we offer systems to meet your needs whether it is

the degree of purity of the water, from pre-treatment

over pure to ultrapure water, the possibility of hot wa-

ter sanitation or the quantity of water you need.

Our innovative systems comply with the strict requirements of the pharmaceutical and cosmetic industry, and excel in qual­ity and design.

Cleanest water for pharmacy and cosmeticsA B S O L U T E P U R I T Y A N D

B AC T E R I A- F R E E Q UA L I T Y O F

T H E WAT E R …

… are the basic requirements for

pharmaceutical and cosmetic pro-

ducts. No other branch of industry

places such high demands on pure

water. And this is good as the pu-

rified water finds a direct way into

the products themselves.

Pharmaceutical unit: System UltiMATE 20000

Page 3: USF Folder english FIN2 · Pre-Treatment: Only purified water can be clean water 03 FILTERS: L Cartridge filtration: various filter types pos- sible, string wound filters, pleated

Pre-Treatment: Only purified water can be clean water

03

F I LT E R S :

L Cartridge filtration: various filter types pos-

sible, string wound filters, pleated filters and

melt blown depth filters.

L Multimedia-filter: filtration up to 5 μm, with

central control or individual valve control, ma-

terial plastic PVC, PP, PVDF or stainless steel

L Ultrafiltration systems: for problematic

feedwater with high particle quantity or high

organic content. Fully automatic control with

Siemens PLC => automatic backwash and op-

tional automatic disinfection of the UF mem-

branes possible

USF Water Purification covers all possible treatment stages for the safe cleaning of your water. We always focus on your needs and also the content of raw water – because each water type is different. USF Water Purification can rely on a large, existing product portfolio.

S P E C I A L F I LT E R S TAT I O N S –

I RO N / M A N G A N E S E R E M OVA L :

L Filter systems even for the most problematic

feedwater, they can also be used in the pres-

ence of hydrogen sulphide H2S with central

control or individual valve control, material

plastic PVC, PP, PVDF or stainless steel

C H LO R I N E R E M OVA L :

L either by activated carbon: also hot water

sanitizable

L by sodium bisulphite dosage

L by UV treatment: feeding up to 1 mg/l free

chlorine, after UV chlorine is no longer de-

tectable.

WAT E R S O F T E N E R S :

Our softener units, similarly to our filter systems,

can handle small quantities and also several

hundred cubic meters of water per hour. They

are controlled by a central control valve or by

PLC and individual valve control. Smaller equip-

ment operates in duplex mode, larger ones in

parallel or duplex operation.

 Pharmaceutical unit:Softener UltiSOFT

Page 4: USF Folder english FIN2 · Pre-Treatment: Only purified water can be clean water 03 FILTERS: L Cartridge filtration: various filter types pos- sible, string wound filters, pleated

BIO

SO

FT

BIO

SO

FT

MW

BIO

SO

FT

M

W/H

WB

IOS

OF

T

MW

/HW

PL

US

ULT

ISO

FT

Op

erat

ion

Par

alle

l ope

rati

on

Mu

ltiw

ay o

pera

tio

nM

ult

iway

ope

rati

on

Mu

ltiw

ay o

pera

tio

nM

ult

iway

ope

rati

on

Mat

eria

lP

last

icP

last

icSt

ain

less

ste

el in

cl.

inte

rnal

par

ts s

uch

as

resi

n t

raps

an

d r

iser

pipe

s

Stai

nle

ss s

teel

incl

.

inte

rnal

par

ts s

uch

as

resi

n t

raps

an

d r

iser

pipe

s

Stai

nle

ss s

teel

incl

.

inte

rnal

par

ts s

uch

as

resi

n t

raps

an

d r

iser

pipe

s

Co

ntr

ol

Cen

tral

co

ntr

ol v

alve

Cen

tral

co

ntr

ol v

alve

Cen

tral

co

ntr

ol v

alve

Cen

tral

co

ntr

ol v

alve

Sin

gle

valv

e co

ntr

ol

Cap

acit

y co

ntr

ol

Qu

anti

ty c

on

tro

lled

Qu

anti

ty o

r q

ual

ity

con

tro

lled

Qu

alit

y co

ntr

olle

dQ

ual

ity

con

tro

lled

Qu

alit

y co

ntr

olle

d

San

itiz

atio

nC

hem

ical

man

ual

Ch

emic

al –

man

ual

Ho

t w

ater

com

plet

e eq

uip

-

men

t –

au

tom

atic

Ho

t w

ater

, eac

h

soft

ener

ves

sel i

s

ind

epen

den

t o

f th

e

oth

er –

au

tom

atic

Ho

t w

ater

, eac

h

soft

ener

ves

sel i

s

ind

epen

den

t o

f th

e

oth

er –

au

tom

atic

04

Page 5: USF Folder english FIN2 · Pre-Treatment: Only purified water can be clean water 03 FILTERS: L Cartridge filtration: various filter types pos- sible, string wound filters, pleated

Production: Strong series for the purest water

05

Our water treatment units of the series UltiMATE, OptiMATE, EcoMATE, DoubleMATE-RO and the CDI-/CEDI systems produce purified water in the purity levels of Purified Water and Highly Puri-fied Water; their performance ranges are from 200 l/h up to 20,000 l/h. All models comply with the guidelines of the European Pharma-copoeia and the United States Pharmacopeia USP.

Our systems in the series UltiMATE, OptiMATE or EcoMATE pro-duce Purified Water with a combination of reverse osmosis and a CEDI module.

The DoubleMATE-RO water purification systems produce Purified Water with double-stage reverse osmosis.

The CDI-/CEDI systems can be used as post-purification for RO sys-tems to produce Purified Water.

Page 6: USF Folder english FIN2 · Pre-Treatment: Only purified water can be clean water 03 FILTERS: L Cartridge filtration: various filter types pos- sible, string wound filters, pleated

ULT

IMA

TE

OP

TIM

AT

EE

CO

MA

TE

DO

UB

LE

MA

TE

CE

DI-

LX

Pu

rifi

cati

on

tec

hn

olo

gyR

O/C

ED

IR

O/C

ED

IR

O/C

ED

IR

O/R

OC

ED

I

Pip

ing

Stai

nle

ss s

teel

Stai

nle

ss s

teel

PV

C, o

ptio

nal

stai

nle

ss s

teel

Stai

nle

ss s

teel

Stai

nle

ss s

teel

Au

tom

atio

n g

rad

eH

igh

est

leve

lM

ediu

m le

vel

Low

er le

vel

Med

ium

leve

lLo

wer

leve

l

Co

ntr

ol s

yste

mS7

-15

00

S7-1

50

0S7

-15

00

S7-1

50

0S7

-15

00

HM

I siz

e1

5“

12

“9

“1

2“

7“

Co

ld W

FI q

ual

ity

Opt

ion

alN

ot

poss

ible

No

t po

ssib

leN

ot

poss

ible

No

t po

ssib

le

Mem

bra

ne

deg

assi

ng

Opt

ion

alO

ptio

nal

No

t po

ssib

leO

ptio

nal

Opt

ion

al

Ch

lori

ne

rem

oval

Act

ivat

ed c

arb

on

/

Sod

ium

bis

ulp

hit

e/

UV

Act

ivat

ed c

arb

on

/

Sod

ium

bis

ulp

hit

e/

UV

Act

ivat

ed c

arb

on

/

Sod

ium

bis

ulp

hit

e

Act

ivat

ed c

arb

on

/

Sod

ium

bis

ulp

hit

e/

UV

N/A

Rem

ote

acc

ess

Opt

ion

alO

ptio

nal

Opt

ion

alO

ptio

nal

Opt

ion

al

San

itiz

atio

nH

ot

wat

er –

fully

au

tom

atic

Ho

t w

ater

fully

au

tom

atic

Ch

emic

al m

anu

al,

chem

ical

au

tom

atic

opt

ion

al

Ho

t w

ater

fully

au

tom

atic

Ho

t w

ater

fully

au

tom

atic

Reg

ula

tio

n o

f th

e p

rod

uct

ion

rat

e

Eco

MO

TIO

N: e

qu

ipm

ent

per

for-

man

ce 5

0-1

00

% a

dju

stab

le

Opt

ion

alN

ot

poss

ible

No

t po

ssib

leN

ot

poss

ible

No

t po

ssib

le

RO

co

nce

ntr

ate

reve

rse

osm

osi

s

Co

nzR

O: r

ecov

ery

up

to

90

%

Opt

ion

alN

ot

poss

ible

No

t po

ssib

leO

ptio

nal

No

t po

ssib

le

06

Page 7: USF Folder english FIN2 · Pre-Treatment: Only purified water can be clean water 03 FILTERS: L Cartridge filtration: various filter types pos- sible, string wound filters, pleated

With our RingMATE system and storage tank we offer an indivi-dual solution for the storage and distribution of your ultrapure water to every point-of-use, in a way to reduce the risk of any bacteria growth or any other contamination of the water. Sanitization can be carried out with constant ozonisation of the storage tank or hot water. An UV unit is used as additional bacte-ria control. The ultrapure water reaches the points-of-use via an engineered distribution system.

07

Storage and distribution: valuable ultrapure water from the collection points

R I N G M AT E S Y S T E M :

L Distribution system

L Skid structure

L Fully piped with stainless steel

L With UV unit for bacteria control

L The aseptic double-tube heat exchanger

ensures continuous cooling and optionally hot

water sanitization.

L Sanitization: alternatively with hot water or

ozone

L Single pump or optional double pump station

for redundancy

L Complete measurement and control technol-

ogy included

L Control: optionally with its own PLC and touch

panel or from the production system

S TO R AG E TA N K :

L Made of stainless steel, electropolished

option ally available

L Pressureless version or pressure tank possible

L Not insulated or with fully welded insulation

L Complete measurement technology inclu ded:

level sensor, safety devices such as rupture

discs or safety valves, overfill/dry-run pro-

tection

L Tank connection: with Tri-Clamp or NA-

Connect

L Optional: Riboflavin test possible with FAT,

optional

Pharmaceutical unit:Distribution RingMATE

Page 8: USF Folder english FIN2 · Pre-Treatment: Only purified water can be clean water 03 FILTERS: L Cartridge filtration: various filter types pos- sible, string wound filters, pleated

C O N TAC T

USF Water Purification GmbH

Concorde Business Park 1/B3/5

2320 Schwechat

Austria

Tel.: +43 1 8905099

Fax: +43 1 8905099 100

E-Mail: [email protected]

Website: www.usf-water.com

USF Water Hungary Kft.

Patak utca 11/A

2112 Veresegyház

Magyarország

Tel.: +36 28 99 96 82

Fax: +36 28 99 96 81

E-Mail: [email protected]

Weblap: www.usf-water.hu