usp hanger catalog
TRANSCRIPT
USPPROFESSIONALDESIGNMANUALandPRODUCTCATALOG
56
thEditio
n
©2011 United Steel Products Company
USP 2173-111
USP MANUFACTURING& WAREHOUSE FACILITIES
Follow us on:
http://www.facebook.com/uspconnectors
http://www.twitter.com/uspconnectors
USP PROFESSIONAL DESIGN MANUALand PRODUCT CATALOG
56th Edition
concrete& masonry
connectors
rollstrapping
rafter tiedowns& plated truss
connectors
epoxies &mechanical
anchors
goldcoatconnector
series
hangers,angles
& straps
connect withconfidence
new PHDAholdown
series
A SUBSIDIARY OF MITEK INDUSTRIES, A BERKSHIRE HATHAWAY COMPANYA SUBSIDIARY OF MITEK INDUSTRIES, A BERKSHIRE HATHAWAY COMPANY
CCUUSSTTOOMMEERR SSEERRVVIICCEE//TTEECCHHNNIICCAALL AASSSSIISSTTAANNCCEE:: Phone: 1-800-328-5934
Fax: 1-952-898-8605
CORPORATE OFFICE14305 Southcross Drive - Suite 200
Burnsville, Minnesota 55306
Phone: 1-800-328-5934/1-952-898-8772
MANUFACTURING/WAREHOUSESMontgomery, Minnesota
Livermore, California
Largo, Florida
Thornhill, Ontario
Houston, Texas
Lumberton, New Jersey
USP HAS PARTNERED WITH STRUCTURAL SOFT TO PROVIDE THEINDUSTRY WITH THE BEST DESIGN SOFTWARE POSSIBLE!
USP2173-111
USP Index
1-800-328-5934 • www.USPconnectors.com 3
©C
op
yrig
ht
2011
US
PS
tru
ctu
ralC
on
nec
tors
®
A3 Angle Clip . . . . . . . . . . . . . . .65-66AB Anchor Bolts . . . . . . . . . . . . . . .30ABS12 Anchor Bolt Stabber . . . . . .28AC Angle Clips . . . . . . . . . . . . . .65-66ACR Adhesive (CIA-EA) . . . . . . . . .26Alternate Installations . . . . . . . . . .180ANJ44S Heavy Angles . . . . . . . . . .69B Corner Braces . . . . . . . . . . . . . . .70BD Bolt Down . . . . . . . . . . . . . . . .188BL Corner Braces . . . . . . . . . . . . . .70BN Breakfast Nook Hangers . . . . .169BP Bearing Plates . . . . . . . . . . . . . .17BPH Beam & Purlin Hangers . . . .123,
127, 129, 131, 133-134C Post Caps . . . . . . . . . . . . . . . . . .55CBE Column Bases . . . . . . . . . . . .52CBSQ Column Bases . . . . . . . . . . .53CLPBF Butterfly Hanger . . . . . . . .162CMST Coiled Strapping . . . . . . . . .72CMSTC16 Coiled Strapping . . . . . .72Corrosion Resistant Products . . . .199CPB Composite Post Bases . . . . . .56CSH Concealed Stringer Hanger .189D Post Anchors . . . . . . . . . . . . . . . .53DC1 Drywall Clip . . . . . . . . . . . . . .191DC50 Deck Clip . . . . . . . . . . . . . . .188DSC4 Drag Strut Connector . . . . .179DTB-TZ Deck Tie Bracket . . . . . . .187DTC Truss Anchor . . . . . . . . . . . . .149DUC Ductile Undercut Anchors . . . .25EBG44 Elevated Post Base . . . . . .51EPB Elevated Post Bases . . . . . . .51EPCM End Post Caps . . . . . . . . . . .54ERB24 Fence Bracket . . . . . . . . .186EWP Hanger Selector Guide . . . . .111EWP Installation . . . . . . . . . . .114-115FA3 Foundation Anchors . . . . . . . . .31FB Fence Brackets . . . . . . . . . . . .186FC Fence Bracket . . . . . . . . . . . . .186FRB Fence Brackets . . . . . . . . . . .186FS Truss Field Splice Kits . . . . . . .177FSS Truss Field Splice Kits . . . . . .177FT Concrete Form Ties . . . . . . . . . .30FTC Floor Truss Clips . . . . . . . . . .174GEL Adhesive (CIA-GEL 7000) . . .27GHF Glulam Face Mount Hangers 137GT Girder Truss Hangers . . .171-172GTD Girder Truss Hangers . .171-172GTS Girder Truss Hangers . .171-172GTWS Girder Truss Hangers . . . .173Hanger Selector Guide . . . . . . . . . .84HBPS Bearing Plates . . . . . . . . . . .17HC520 Hurricane/Seismic Anchor . . . .
155,157
HCPRS Hurricane/Seismic Anchors . .155, 157
HD Face Mount Hangers . . . . .89-95, 116, 120-122
HDO Top Mount Hangers .96, 98-100HDQ Inverted Flange Hangers . . .89,
92-95, 117, 121-122HGA Hurricane Gusset Angles . . .154HH Header Hangers . . . . . . . . . . . . 68HHC Hip/Hip Connectors . . . .169-170HHCP2 Hurricane/Seismic Anchor . . .
155, 157HJC Hip/Jack Connectors . . .169-170HJHC Hip/Jack Connectors . .169-170HL Light Gauge Purlin Hangers .97-99HLBH Beam Hangers . . . . . . . . .124,
129-131, 133-134HLPTA75 Truss Anchor . . . . . . . .146HPA Purlin Anchors . . . . . . . . . .45-46HPAHD Foundation Straps . . . .41-42HTA Truss Anchors . . . . . . . .147-148HTC4 Heavy Truss Clip . . . . . . . .176HTHJ Hip/Jack Connectors . .169-170HTT Tension Ties . . . . . . . . . . . . . .37HTT14S Holdown . . . . . . . . . . . . . .47HTW Twist Straps . . . . . . . . . . .78-79HTWM Twist Straps . . . . . . . . . . . .81HUGT Girder Tiedowns . . . . . . . . .153HUS Slant Nail Hangers . . .88, 90-94,
117, 121, 162HWUH Top Flange Hangers .106-107ICPL Protection Plates . . . . . . . . .183IS Insulation Supports . . . . . . . . . .191JA Joist Angles . . . . . . . . . . . . .65-66JDS Purlin Hangers . . . . . . . . . . .105JH Multi-Purpose Joist Hangers . .101JL Standard Joist Hangers .87, 90-91JLIF-TZ Inverted Flange Hangers . .87,
90-91JN Power Nail Hangers . . . . . . . .193JN(E) Power Nail Hangers . . . . . .193JNP Mending Plates . . . . . . . . . . .192JPF Purlin Hangers . . . . . . . . . . . .104JUS Slant Nail Joist Hangers 88, 90-94KCBQ Column Bases . . . . . . . . . . .52KCCQC Column Caps . . . . . . . .57-58KCCQO Column Caps . . . . . . . .57-58KCCQOB Column Caps . . . . . .57-58KCCQ Column Caps . . . . . . . . .57-58KCCQT Column Caps . . . . . . . .57-58KECCQL End Column Caps . . .57-58KECCQO End Column Caps . . .57-58KECCQ End Column Caps . . . .57-58KEG Glulam Beam Hangers . . . . .138
KF Panel Hangers . . . . . . . . . . . . .104KGB Glulam Hangers . . . . . . . . . .139KGH Floor Girder Hangers . . . . . . .34KGLB Laminated Beam Seats . . . .33KGLBT Laminated Beam Seats . . .33KGLS Glulam Saddle Hangers . . .143KGLST Glulam Saddle Hangers . .143KGLT Glulam Beam Hangers . . . .140KHC Hinge Connectors . . . . .141-142KHCCT Hinge Connectors . . .141-142KHCST/KHCSTR Seismic Straps . . . .
141-142KHCT Hinge Connectors . . . .141-142KHGB Glulam Hangers . . . . . . . . .139KHGLB Laminated Beam Seats . . .33KHGLS Glulam Saddle Hangers .143KHGLST Glulam Saddle Hangers 143KHGLT Glulam Beam Hangers . . .140KHHB Glulam Hangers . . . . . . . . .139KHL Heavy Angles . . . . . . . . . . . . .69KHSA Connector Straps . . . . . .81-82KHST Strap Ties . . . . . . . . . . . . . . .76KHW Top Flange Hangers . . . .97, 100KLCC Lally Column Caps . . . . .56-57KLEG Glulam Beam Hangers . . . .138KMEG Glulam Beam Hangers . . .138KNS1 Protection Plate . . . . . . . . .183KRPS Strap Ties . . . . . . . . . . . . . . .76KSA Connector Straps . . . . . . .81-82KSCT68 Corner Tie . . . . . . . . . . . .192KST Strap Ties . . . . . . . . . . . . . .73-75KSTI Strap Ties . . . . . . . . . . . . .73-75KVB Knee Braces . . . . . . . . . . . . . .82KVBI Knee Braces . . . . . . . . . . . . .82L Straps . . . . . . . . . . . . . . . . . . . . . .70LBP Bearing Plates . . . . . . . . . . . . .17LBPS Bearing Plates . . . . . . . . . . .17LDSC4 Drag Strut Connector . . . .179LFTA6 Twist Strap . . . . . . . . . . .78-79LJC-TZ Lateral Joist Connector . . .68LJQ-TZ Lateral Joist Connectors . .68LPTA Embedded Truss Anchors . .145LS Light Slope Hangers . . . . . . . .101LSSH Slope/Skew Hangers . . . . .136LSTA Strap Ties . . . . . . . . . . . . .73-74LSTAD Foundation Straps . . . . .43-44LSTI Strap Ties . . . . . . . . . . . . . 73-74LTS Tension Ties . . . . . . . . . . . . . . .37LTS20B Holdown . . . . . . . . . . . . . .47LTTI31 Tension Tie . . . . . . . . . . . . .37LTW Twist Straps . . . . . . . . . . . .78-79LUGT Girder Tiedowns . . . . . 151-152Lumberlok Screws . . . . . . . . .22-23MB16 Bridging . . . . . . . . . . . . . . . 182
* New Products
*
*
*
1-800-328-5934 • www.USPconnectors.com4
©C
op
yrigh
t2011
US
PS
tructu
ralCo
nn
ectors
®USP Index continued
1-800-328-5934 • www.USPconnectors.com
Reference Number Index on next page
MBG Bridging . . . . . . . . . . . . . . . .182MP Framing Angles . . . . . . . . . .65-66MP_F Multi-Lateral Plate Ties . .62-63MP34 Framing Angle . . . . . . . . .62-63MPA1 Framing Angles . . . . . . . .62-63MPH Masonry Hangers . . . . .108-109,
125-134MRT7 Power Nail Hanger . . . . . . .193MSH Strap Hangers . . . . . . . .163-165MSH213L/R Skewed Truss Hanger166MSSH217 Skewed Hanger . . . . . .167MSTA Strap Ties . . . . . . . . . . . . .73-74MSTAM Masonry Straps . . . . . . . . .80MSTC Strap Ties . . . . . . . . . . . .73-75MSTC66B3 Pre-Bent Strap . . . . . . .77MSTCM Masonry Straps . . . . . . . . . 80MTHF Power Nail Hangers . . . . . .193MTW Twist Straps . . . . . . . . . . .78-79MUGT15 Girder Tiedown . . . . . . .152MUS Slant Nail Joist Hangers . . . . .88,
90,162N Bridging . . . . . . . . . . . . . . . . . . .181N Nails . . . . . . . . . . . . . . . . . . . .15-16NFM Masonry Hangers . . . . . . . . .110NOP Moisture Barrier Plates . . . . .145NP Mending Plates . . . . . . . . . . . .192O Bridging . . . . . . . . . . . . . . . . . . .181Ornamental series . . . . . . . . . . . . .71PA Post Anchors . . . . . . . . . . . . . . .49PA Purlin Anchors . . . . . . . . . . .45-46PA(E) Post Anchors . . . . . . . . . . . .49PAHD42 Foundation Strap . . . .41-42PAI Purlin Anchors . . . . . . . . . . .45-46PAU Post Anchors . . . . . . . . . . . . . .49PB Post Caps . . . . . . . . . . . . . . . . .55PBC Post Beam Corner . . . . . . . . .56PBES Post Caps . . . . . . . . . . . . . . .55PBS Post Caps . . . . . . . . . . . . . . . .55PC Plywood Clips . . . . . . . . . . . . .191PCM Post Caps . . . . . . . . . . . . . . . .54PCP Plastic Post Caps . . . . . . . . .190PHD Predeflected Holdowns . . . . . .36PHDA Predeflected Holdowns . . . .36PHG Panel Hangers . . . . . . . . . . .104PHM Top Flange Hangers . . .125-134PHXU Top Flange Hangers . .125-127,
129-131, 133-134PL4 Protection Plate . . . . . . . . . . .183PRT2 Pipe Rail Tie . . . . . . . . . . . .186PS Strap Ties . . . . . . . . . . . . . . . . .76PWFS24 Wood Foundation Strap . .83RBC Roof Boundary Clip . . . . . . . .64RC Plywood Clips . . . . . . . . . . . . .191RFUS Uplift Girder Tie . . . . . . . . .151RP6 Retro Plate . . . . . . . . . . . . . . .34
RS Coiled Strapping . . . . . . . . . . . .72RSPT Stud Plate Ties . . . . . . . . . . .67RT Hurricane/Seismic Anchors 155-157RT16M Hurricane Retrofit Connector . .
154-155RUSC Strap Connector . . . . . . . . .149RWB Wall Bracing . . . . . . . . . . . . .184SBP Bearing Plates . . . . . . . . . . .175SCA Stair Angles . . . . . . . . . . . . .189SDJT14 Deck Post Tie . . . . . . . . .187SDPT Deck Post Ties . . . . . . . . . .187SFP Fence Post Connectors . . . .185SHA Masonry Uplift Connectors . .153SKH Skewed 45° Hangers . .102-103SKHH Skewed 45° Hangers .102-103SMP Fence Post Connectors . . . .185SNP3 Skewed Nail Plate . . . . . . .168Specialty Options . . . . . . . . .194-198Specification Tools . . . . . . . . . . .203SPT Stud Plate Ties . . . . . . . . . . . .67SPTH Stud Plate Ties . . . . . . . . . . .67ST Foundation Anchors . . . . . . . . . .32ST Strap Ties . . . . . . . . . . . . . . .73-74ST24H Truss Brace & Spacer . . . .178STAD Foundation Straps . . . . . .43-44STB Anchor Bolts . . . . . . . . . . . .28-29STBL Anchor Bolts . . . . . . . . . .28-29STC Scissor Truss Clips . . . . . . . .173STS Stud Shoes . . . . . . . . . . . . . .185SUH Joist Hangers . . . . . . .87, 90-95SW Top Flange Hangers . . . . . .97-99SWH Top Flange Hangers . . . .97-100T Hoist Plates . . . . . . . . . . . . . . . .190T Straps . . . . . . . . . . . . . . . . . . . . . .70TA Foundation Straps . . . . . . . .44-45TA Truss Anchors . . . . . . . . . .147-148TAR Truss Anchors . . . . . . . .147-148TD Holdowns . . . . . . . . . . . . . . .38-39TDL Concrete Angles . . . . . . . . . . .47TDS Holdowns . . . . . . . . . . . . . . . .47TDX Holdowns . . . . . . . . . . . . . .38-39TFI Top Mount Hangers .123, 128-131TFL Top Mount Hangers .123, 127-128THD Face Mount Truss Hangers .118,
121-122, 160THDH Face Mount Hangers . . . . .118,
121-122, 161THF Face Mount Hangers 116,119-120THO Top Mount Hangers 123, 127-132THR Threaded Rods . . . . . . . . . . . .28TMP Rafter-To-Plate Connectors .135TMPH Rafter-To-Plate Connectors 135TPP Mending Plates . . . . . . . . . . .192TR Roof Truss Ties . . . . . . . . . . . .176TS Truss Spacer . . . . . . . . . . . . . .179
TSX Truss Spacers . . . . . . . . . . . .179UMH Universal Masonry Hangers 109UPHD Holdowns . . . . . . . . . . . . . . .40USC Uplift Girder Ties . . . . . . . . . .150WAS Wet Post Anchors . . . . . . . . .50WB Wall Bracing . . . . . . . . . . . . . .184WBC Wall Bracing . . . . . . . . . . . . .184WBT Wall Bracing . . . . . . . . . . . . .184WE Wet Post Anchors . . . . . . . . . . .50WG Concrete Form Wedge . . . . . . .30WS Wood Screw Applications . .19-21WS Wood Screws . . . . . . . . . . . . . .18WT22 Wall Ties . . . . . . . . . . . . . . .190ZC Blocking Supports . . . . . . . . . .176
* New Products
*
*
*
USP2173-111
1-800-328-5934 • www.USPconnectors.com 5
©C
op
yrig
ht
2011
US
PS
tru
ctu
ralC
on
nec
tors
®Reference Number Index
About the Reference NumbersReference numbers shown throughout thecharts in this catalog are part numbers whichmay be more familiar to customers in variousregions of the United States. These areincluded for the convenience of our newcustomers who have recently switched from acompetitor’s product line to USP.
The reference numbers in this catalog arefor general application comparison onlyand should not be used as a substitutiontool. The user is responsible to comparespecific load values, fastener schedules,material specifications, and other factorsto determine suitability of use for anyparticular product.
A Angle . . . . . . . . . . . . . . . . . . .47, 65-66, 70A34/A35 Anchor . . . . . . . . . . . . . . . . . . . .63AB/ABA/ABE/ABU Post Base . . . . . . . . .49AC/ACE Post Cap . . . . . . . . . . . . . . . . . . 55B,/BA Hanger . . . . . .98-100, 127, 129-134BC Base . . . . . . . . . . . . . . . . . . . . . . . . . .53BC Cap . . . . . . . . . . . . . . . . . . . . . . . . . . .55BP Bearing Plate . . . . . . . . . . . . . . . . . . . .17BT Brick Tie . . . . . . . . . . . . . . . . . . . . . . .190CB/CBQ Column Base . . . . . . . . . . . . . . .52CBS/CBSQ Column Base . . . . . . . . . . . . .53CC/CCQ Column Cap . . . . . . . . . . . . . . .57CMST Strap . . . . . . . . . . . . . . . . . . . . . . .72CMSTC Coiled Strap . . . . . . . . . . . . . . . .72CPS Composite Standoff . . . . . . . . . . . . .56CS Strap . . . . . . . . . . . . . . . . . . . . . . . . . .72CWB Wall Bracing . . . . . . . . . . . . . . . . .184DBTZ Deck Tie . . . . . . . . . . . . . . . . . . . .188DJT Deck Tie . . . . . . . . . . . . . . . . . . . . .187DPPC Decorative Post Cover . . . . . . . . .190DPT Deck Tie . . . . . . . . . . . . . . . . . . . . .187DS Drywall Stop . . . . . . . . . . . . . . . . . . .191DSC Drag Strut Connector . . . . . . . . . . .179DSP Double Stud Plate . . . . . . . . . . . . . .67DTC Roof Truss Clip . . . . . . . . . . . . . . .176DTT2Z Deck Tension Tie . . . . . . . . . . . .187ECC/ECCQ Column Cap . . . . . . . . . . . . .57EG Hanger . . . . . . . . . . . . . . . . . . . . . . .138EPB Post Base . . . . . . . . . . . . . . . . . . . . .51EPC Post Cap . . . . . . . . . . . . . . . . . . . . .54F Hanger . . . . . . . . . . . . . . . . . . . . . . . .104FB Fence Bracket . . . . . . . . . . . . . . . . .186FPBB44 E-Z Base . . . . . . . . . . . . . . . . .188FPBM44 E-Z Mender . . . . . . . . . . . . . . .185FPBS44 E-Z Spike . . . . . . . . . . . . . . . . .185GA Angle . . . . . . . . . . . . . . . . . . . . . . . . .65GB Hanger . . . . . . . . . . . . . . . . . . . . . . .139GBC Gable Bracing . . . . . . . . . . . . . . . .157GH Hanger . . . . . . . . . . . . . . . . . . . . . . . .34GLB/GLBT Beam Seat . . . . . . . . . . . . . .33GLS Hanger . . . . . . . . . . . . . . . . . . . . . .143GLT Hanger . . . . . . . . . . . . . . . . . . . . . .140GLTV Hanger . . . . . . . . . .129-131, 133-134H Hurricane Ties . . . . . . . . . . . . . . .79, 157HB Hanger . . . . . . . . . . . .129-131, 133-134HCA Hinge Connector . . . . . . . . . . . . . .141HCP Hip Corner Plate . . . . . . . . . . . . . .157HCST Strap . . . . . . . . . . . . . . . . . . . . . .142HD/HDA Holdown . . . . . . . . . . . . . . . . . .39HDQ Holdown . . . . . . . . . . . . . . . . . . . . .40HDU Holdown . . . . . . . . . . . . . . . . . . . . . .36HETA/HETAL Truss Anchor . . . . . .148-149HFN Hanger . . . . . . . . . . . . . . . . . . . . . .104HGA/HGAM Gusset Angle . . . . . . . . . . .154HGB Hanger . . . . . . . . . . . . . . . . . . . . . .139HGLB Beam Seat . . . . . . . . . . . . . . . . . .33HGLS Hanger . . . . . . . . . . . . . . . . . . . . .143HGLT Hanger . . . . . . . . . . . . . . . . . . . . .140HGLTV Hanger . . . . . . . . 130-131, 133-134
HGT Girder Tiedown . . . . . . . . . . . . . . .153HGUS Hanger . . . . . . . . . . . . .121-122, 161HH Hanger . . . . . . . . . . . . . . . . . . . . . . . .68HHB Hanger . . . . . . . . . . . . . . .99-100, 139HHDQ Holdown . . . . . . . . . . . . . . . . . . . .40HHUS Hanger . . . . . . . . . . . . .121-122, 160HIT Hanger . . . . . . . . . . . . . . .128-129, 131HL Angle . . . . . . . . . . . . . . . . . . . . . . . . . .69HM Hurricane Tie . . . . . . . . . . . . . . . . . .155HPA Purlin Anchor . . . . . . . . . . . . . . . . . .46HPAHD Holdown . . . . . . . . . . . . . . . . . . .42HS Hurricane Tie . . . . . . . . . . . . . . . . . .157HSA Strap . . . . . . . . . . . . . . . . . . . . . . . .82HST Strap . . . . . . . . . . . . . . . . . . . . . . . . .76HSUR/HSUL Hanger . . . . . . . . . . . . . . .103HTC Heavy Truss Clip . . . . . . . . . . . . . .176HTS Twist Strap . . . . . . . . . . . . . . . . . . . .79HTSM Twist Strap . . . . . . . . . . . . . . . . . .81HTT Tension Tie . . . . . . . . . . . . . . . . . . . .37HTU Hanger . . . . . . . . . . . . . . . . . . . . . .160HU Hanger . . . . . . . . . .90-95, 119-122,162HUCQ Hanger . . . . . . . . . . .91-95, 121-122HUS Hanger . . . . . . . . . . . .90-94, 121, 162HUSTF Hanger . . . . . . . . . . . . . . . . . .98-99HUITF/HUTF Hanger . . . . . . . . . . . .98-100HW Hanger . . . . . . . . . . . . . . . . . . . .99-100HWI Hanger . . . . . . . . . . . . . .129-131, 134HWU Hanger . . . . . . . . . .129-131, 133-134IS Insulation Support . . . . . . . . . . . . . . .191ITS Hanger . . . . . . . . . . . . . . . . . . .127-128ITT Hanger . . . . . . . . . . . . . . . . . . .127-131IUS Hanger . . . . . . . . . . . . . . . . . . .119-120IUT Hanger . . . . . . . . . . . . . . . . . . .119-120JB Hanger . . . . . . . . . . . . . . . . . . . . . . . .98L Angle . . . . . . . . . . . . . . . . . . . . . . . . . . .66L Strap Tie . . . . . . . . . . . . . . . . . . . . . . . .70LB Hanger . . . . . . . . . . . . . . . . . . . . . . . .98LBOLT Anchor Bolt . . . . . . . . . . . . . . . . .30LBP Bearing Plate . . . . . . . . . . . . . . . . . .17LBV Hanger . . . . . . . . . . . . . . . . . .127-133LCB Column Base . . . . . . . . . . . . . . . . . .52LCC Lally Column Cap . . . . . . . . . . . . . .57LCE Post Cap . . . . . . . . . . . . . . . . . . . . .55LEG Hanger . . . . . . . . . . . . . . . . . . . . . .138LGT Girder Tiedown . . . . . . . . . . . . . . . .152LPC Post Cap . . . . . . . . . . . . . . . . . . . . .55LS Angle . . . . . . . . . . . . . . . . . . . . . . . . . .65LSCZ Stringer Connector . . . . . . . . . . . .189LSSU Hanger . . . . . . . . . . . . . . . . . . . . .136LSTA Strap Tie . . . . . . . . . . . . . . . . . . . . .74LSTI Strap Tie . . . . . . . . . . . . . . . . . . . . .74LSTHD Holdown . . . . . . . . . . . . . . . . . . .43LSU Hanger . . . . . . . . . . . . . . . . . . . . . .136LTA Truss Anchor . . . . . . . . . . . . . . . . . .145LTB Bridging . . . . . . . . . . . . . . . . . . . . . .181LTP Framing Anchor . . . . . . . . . . . . . . . .63LTS Twist Strap . . . . . . . . . . . . . . . . . . . .79LTT/LTTI Tension Tie . . . . . . . . . . . . . . . .37LU/LUCZ/LUS Hanger . . . . . . . . . . . .90-94MAB Mudsill Anchor . . . . . . . . . . . . . . . . .32MAS/MASA/MASP Mudsill Anchor . . . . .31MBHA/MBHU Masonry Hanger . . .109-110MEG Hanger . . . . . . . . . . . . . . . . . . . . .138META Truss Anchor . . . . . . . . . . . . . . . .148MGT Girder Tiedown . . . . . . . . . . . . . . .152MIT Hanger . . . . . . . . . . . . . . . . . . .127-132MIU Hanger . . . . . . . . . . . . . . . . . . .119-122MMLU Hanger . . . . . . . . . . . . . . . . . . . .193MP Mending Plate . . . . . . . . . . . . . . . . .192MST Strap Tie . . . . . . . . . . . . . . . . . . . . .75MSTA Strap Tie . . . . . . . . . . . . . . . . . . . .74MSTAM Strap Tie . . . . . . . . . . . . . . . . . . .80MSTC Strap Tie . . . . . . . . . . . . . . . . . .74-75MSTCB Strap Tie . . . . . . . . . . . . . . . . . . .77MSTCM Strap Tie . . . . . . . . . . . . . . . . . . .81MSTI Strap Tie . . . . . . . . . . . . . . . . . . . . .75MTHM Hanger . . . . . . . . . . . . . . . . . . . .170
MTS Twist Strap . . . . . . . . . . . . . . . . . . . .79MTSM Twist Strap . . . . . . . . . . . . . . . . . .81MUS Hanger . . . . . . . . . . . . . . . .90-91, 162Nails . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15NCA Nailless Bridging . . . . . . . . . . . . . .182NS/NSP Nail Stopper . . . . . . . . . . . . . . .183O Ornamental . . . . . . . . . . . . . . . . . . . . . .71PA Holdown . . . . . . . . . . . . . . . . . . . . . . .45PA Purlin Anchor . . . . . . . . . . . . . . . . . . .46PAHD Holdown . . . . . . . . . . . . . . . . . . . . .42PAI Purlin Anchor . . . . . . . . . . . . . . . . . . .46PB/PBS Post Base . . . . . . . . . . . . . . . . . .50PC Post Cap . . . . . . . . . . . . . . . . . . . . . . .54PF Hanger . . . . . . . . . . . . . . . . . . . . . . .104PGT Pipe Tie . . . . . . . . . . . . . . . . . . . . .186PS Strap . . . . . . . . . . . . . . . . . . . . . . . . . .76PSCA/PSCL Sheathing Clip . . . . . . . . .191PSPNZ Protective Plate . . . . . . . . . . . . .183RBC Roof Boundary Clip . . . . . . . . . . . . .64RCWB Wall Bracing . . . . . . . . . . . . . . . .184RP Retro Plate . . . . . . . . . . . . . . . . . . . . .34RPS Strap Tie . . . . . . . . . . . . . . . . . . . . . .76RSP Stud Plate Tie . . . . . . . . . . . . . . . . .67S/A23 Angle . . . . . . . . . . . . . . . . . . . . . . .65S/H Hurricane Ties . . . . . . . . . . . . . . . . .157S/HD Holdown . . . . . . . . . . . . . . . . . . . . .47S/HGAM Gusset Angle . . . . . . . . . . . . . .154S/HTT Holdown . . . . . . . . . . . . . . . . . . . .47S/LS Angle . . . . . . . . . . . . . . . . . . . . . . . .65S/LTT Holdown . . . . . . . . . . . . . . . . . . . . .47S/MST Strap Tie . . . . . . . . . . . . . . . . . . . .75S/PSPN Nail Stopper . . . . . . . . . . . . . . .183SA Strap . . . . . . . . . . . . . . . . . . . . . . . . . .82SD Screw . . . . . . . . . . . . . . . . . . . . . . . . .23SDS Screw . . . . . . . . . . . . . . . . . . . . .18-21SP/SPH Stud Plate Tie . . . . . . . . . . . . . . .67SS Stud Shoe . . . . . . . . . . . . . . . . . . . . .185SSP Single Stud Plate . . . . . . . . . . . . . . .67SSTB Anchor Bolt . . . . . . . . . . . . . . . . . .29ST Strap Tie . . . . . . . . . . . . . . . . . . . . . . .74STC Roof Truss Clip . . . . . . . . . . . . . . .176STHD Holdown . . . . . . . . . . . . . . . . . . . . .44SUR/SUL Hanger . . . . . . . . . . . . . .102-103T Strap Tie . . . . . . . . . . . . . . . . . . . . . . . .70TA Staircase Angle . . . . . . . . . . . . . . . . .189TB Tension Bridging . . . . . . . . . . . . . . . .181TBE Truss Enhancer . . . . . . . . . . . . . . .175TC Truss Connector . . . . . . . . . . . . . . . .173THA/THAC/THAI Hanger . . . . . . . .164-165THASR/L Truss Hanger . . . . . . . . . . . . .167THGB/THGBH Hanger . . . . . . . . . . . . . .171THMA Hanger . . . . . . . . . . . . . . . . . . . .172TJC37 Truss Connector . . . . . . . . . . . . .168TP Tie Plate . . . . . . . . . . . . . . . . . . . . . .192TS Twist Strap . . . . . . . . . . . . . . . . . . . . .79TSB Truss Spacer . . . . . . . . . . . . . . . . .178TSF Truss Spacer . . . . . . . . . . . . . . . . .179TSS Truss Seat . . . . . . . . . . . . . . . . . . .145TWB Wall Bracing . . . . . . . . . . . . . . . . .184U Hanger . . . . . . . . . . . . . . .90-95, 119, 121VB Knee Brace . . . . . . . . . . . . . . . . . . . . .82W Hanger . . . . . . . . . . . . . . . . . . . . . .98-99W Wedge . . . . . . . . . . . . . . . . . . . . . . . . .30WB/WBC Wall Bracing . . . . . . . . . . . . . .184WM Hanger . . . . . . .108, 127-130, 132-133WMI Hanger . . . . . . . . . . .130-131, 133-134WNP Hanger . . . . . . . . . . . . . . . . . . .98-100WP Hanger . . . . . . . . . . .127-129, 132-133WPI Hanger . . . . . . . . . . . . . . . . . . .128-134WPU Hanger . . . . . . . . . . . . . .127, 130-131WT Wedge Form Tie . . . . . . . . . . . . . . . .30Z Clip . . . . . . . . . . . . . . . . . . . . . . . . . . .176
1-800-328-5934 • www.USPconnectors.com6
©C
op
yrigh
t2011
US
PS
tructu
ralCo
nn
ectors
®Table of Contents
1-800-328-5934 • www.USPconnectors.com
WARRANTYUnited Steel Products Company warrants its products to be free from defects in materialand workmanship. Said products are further warranted as to adequacy of design, providedproducts are used in strict accordance with United Steel Product Company’s current publisheddesign limits and are installed in a workmanlike manner. (Said warranties do not apply inthe event products are cut, notched, welded, drilled or in any way altered). No warrantyapplies if deterioration occurs due to environmental conditions. United Steel ProductsCompany’s obligations under this warranty shall be limited to the replacement or repair ofthose products demonstrated to be defective. Such remedy shall constitute Customer’ssole and exclusive remedy and Customer hereby agrees that no other remedy (including,
but not limited to claims for INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES,OR ANY CAUSE, LOSS, ACTION, CLAIM OR DAMAGE, INCLUDING LOSS OF TIME,WHATSOEVER, OR INJURY TO PERSON OR PROPERTY OR ANY OTHER CONSEQUENTIALDAMAGE OR INCIDENTAL OR ECONOMIC LOSS) shall be available to Customer whethersaid claims be asserted on the basis of warranty, negligence, strict liability or otherwise. THISWARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED ORIMPLIED, INCLUDING ANY WARRANTIES OF MERCHANTABILITY AND FITNESS FORA PARTICULAR PURPOSE, ALL SUCH OTHER WARRANTIES BEING HEREBYEXPRESSLY EXCLUDED.
Corrosion Information . . . . . . .8-9Design Notes . . . . . . . . . . . . . .12Product Information . . . . . . .7, 10Product Notes . . . . . . . . . . . . . .11Reference Number Index . . . . . .5USP Index . . . . . . . . . . . . . . . .3-4Installation Notes . . . . . . . . . . .13
FastenersSection Overview . . . . . . . . . .14Bearing Plates . . . . . . . . . . . . . .17Nails . . . . . . . . . . . . . . . . . . .15-16Wood Screws . . . . . . . . . . . .18-21Lumberlok Screws . . . . . . . .22-23
Concrete & MasonrySection Overview . . . . . . . . . .24Adhesive & Undercut Anchoring Systems . . . . . . . . . . . . . . .25-27
Anchor Bolts . . . . . . . . . . . .28-30Anchor Bolt Stabber . . . . . . . . .28Concrete Form Ties & Wedge .30Floor Girder Hangers . . . . . . . .34Foundation Anchors . . . . . . .31-32Laminated Beam Seats . . . . . .33Retro Plates . . . . . . . . . . . . . . .34Threaded Rods . . . . . . . . . . . . .28
HoldownsSection Overview . . . . . . . . . .35Cold Formed Steel Holdowns . .47Concrete Angles . . . . . . . . . . . .47Foundation Straps . . . . . . . .41-45Holdowns . . . . . . . . . . . .36, 38-40Purlin Anchors . . . . . . . . . . .45-46Tension Ties . . . . . . . . . . . . . . .37
Caps & BasesSection Overview . . . . . . . . . .48Column Bases . . . . . . . . . . .52-53Column Caps . . . . . . . . . . . .57-58Composite Post Bases . . . . . . .56Elevated Post Bases . . . . . . . . .51Lally Column Caps . . . . . . .56-57Post Anchors . . . . . . . . . . . .49, 52Post Caps . . . . . . . . . . . . . .54-56Wet Post Anchors . . . . . . . . . . .50
Angles & StrapsSection Overview . . . . . . . .59-61Coiled Strapping . . . . . . . . . . . .72Connector Straps . . . . . . . . .81-82Corner Braces . . . . . . . . . . . . . .70Framing Plates & Angles . . .62-66Header Hangers . . . . . . . . . . . .68Heavy Angles . . . . . . . . . . . . . .69Knee Braces . . . . . . . . . . . . . . .82Lateral Joist Connectors . . . . . .68Masonry Straps . . . . . . . . . .80-81Ornamental Connectors . . . . . .71Pre-Bent Straps . . . . . . . . . . . .77Straps . . . . . . . . . . . . . .70, 73-76Stud Plate Ties . . . . . . . . . . . . .67Twist Straps . . . . . . . . . . . . .78-79Wood Foundation Straps . . . . .83
HangersSection Overview . . . . . . . .84-86Face Mount Hangers . . . . . .87-95Masonry Hangers . . . . . . .106-110Panel & Purlin Hangers . .104-105Top Mount Hangers . . . . . .96-101Slope & Skew Hangers . .101-103
EWP HangersSection Overview . . . . . .111-113Adjustable Connectors . . . . . .135EWP Installation Guide . .114-115Face Mount Hangers . . . .116-122Glulam Hangers . . . . . . . .137-143Slope/Skew Hangers . . . . . . .136Top Mount Hangers . . . . .123-134
Truss & Rafter Tiedowns Section Overview . . . . . . . . .144Truss Anchors . . . . . . . . .145-149Girder Tiedowns . . . . . . . .151-153Hurricane Gusset Angles . . . .154Hurricane/Retrofit Connector . . . .
154-155Hurricane/Seismic Anchors . . . . . .
155-157Masonry Uplift Connectors . . .153Moisture Barrier Plates . . . . . .145Uplift Girder Ties . . . . . . .149-151
Plated Truss
Plated TrussSection Overview . . . . . .158-159Alternate Installations . . . . . . .180Blocking Supports . . . . . . . . . .176Drag Strut Connectors . . . . . .179Field Splice Kits . . . . . . . . . . .177Girder Truss Hangers . . .171-173Hip/Jack Connectors . . . .169-170Roof Truss Ties . . . . . . . . . . . .176Skewed Truss Hangers . .166-168Supplemental Bearing Plates .175Truss Clips . . . . . . . . . . . .173-174Truss Hangers . . . . . . . . .160-165Truss Spacers . . . . . . . . .178-179
MiscellaneousBridging . . . . . . . . . . . . . .181-182Corner Tie . . . . . . . . . . . . . . . .192Deck Connectors . . . . . . .187-188Drywall Clip . . . . . . . . . . . . . . .191Fence Hardware . . . . . . .185-186Hoist Plates . . . . . . . . . . . . . . .190Insulation Supports . . . . . . . . .191Mending Plates . . . . . . . . . . . .192Nail Plates . . . . . . . . . . . . . . . .192Plastic Post Caps . . . . . . . . . .190Plywood Clips . . . . . . . . . . . . .191Protection Plates . . . . . . . . . . .183Stair Angles . . . . . . . . . . . . . . .189Stud Shoes . . . . . . . . . . . . . . .185Wall Bracing . . . . . . . . . . . . . .184Wall Ties . . . . . . . . . . . . . . . . .190
Manufactured Housing . . .193
Specialty Options . . . . . . .194-198
Corrosion Resistant Products . .199
Specification Tools . . . . . . . .203
USP2173-111
1-800-328-5934 • www.USPconnectors.com 7
©C
op
yrig
ht
2011
US
PS
tru
ctu
ralC
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com
Product Information
Code Evaluations
Most USP structural products listed inthis catalog have been evaluated or arein the submittal stage for evaluation fromone or more of the following code authorities listed in the chart shown onthe right.
Other code agencies may require specific reductions and limitations andmay have different load values than those presented in this catalog.USP recommends consulting specificcode evaluation or product acceptancecriteria reports that govern in the applicable area. Any questions about current code listings should be directedto the Technical Assistance staff. USPcontinuously updates code reports toreflect new standards and requirements. Visit USP’s Web Site,www.USPconnectors.com/codereports.htm,or specific code agencies web sites forcurrent listings.
Code Watch“Code Watch” items are included tohighlight some sections of the modelbuilding codes that discuss the use ofproducts contained in this catalog. Theuser is strongly encouraged to consultwith a qualified design professional toreview the exact requirements of the relevant code references. Please notethat not all code sections relating to theuse of products contained in this catalog are included. In addition, somestates and local municipalities havedeveloped amendments to the referenced code section. Shown references are for the 2006 InternationalResidential Code (IRC) and 2006International Building Code (IBC).
CodeAgency
ApprovalListing
CodeRef.
CodeAgency
ApprovalListing
CodeRef.
2031C L1 FL565 F1
ER-2039 L2 FL567 F2
ER-2725 L3 FL568 F3
ER-5321 L4 FL569 F4
NER-505 L5 FL570 F5
NER-530 L6 FL571 F6
NER-608 L8 FL574 F7
ESR-1178 1 FL576 F8
ESR-1280 2 FL578 F9
ESR-1702 4 FL817 F12
ESR-1781 5 FL820 F14
ESR-1881 6 FL821 F15
ESR-1970 7 FL822 F16
ESR-2104 8 FL859 F17
ESR-2685 9 FL9835 F18
ESR-1831 10 FL10739 F19
ESR-1465 11 FL11664 F20
ESR-2761 12 FL1247 F22
ESR-2787 13 FL2033 F23
IAPMO-ES ESR ER-0200 20 FL4928 F24
RR 25029 R2 FL5631 F25
RR 25113 R4 FL6223 F26
RR 25843 R5 FL11910 F27
RR 25433 R8 FL11748 F28
RR 25745 R9 FL13170 F29
RR 25753 R10 FL13285 F30
RR 25749 R12 NOA 04-1122.03 D1
RR 25779 R13 NOA 06-0921.05 D2
RR 25836 R14 NOA 07-0214.20 D3
Prescriptive Code -- -- 100 NOA 07-0306.06 D4
NOA 07-0306.10 D5
NOA 07-0322.15 D6
No Load Capacity -- -- 120 NOA 07-0419.01 D7
NOA 07-1003.10 D8
NOA 08-0111.09 D10
New products or updated product NOA 08-0206.07 D11information are designated in bold font. NOA 08-0303.06 D12
NOA 08-0715.01 D13
State ofFloridaProduct
Approvals
Metro Dade -Dade County,
Florida
SBC, UBC, NESLegacy Reports
110
No Code Listing Contact usfor test data
130
ESR
LA City -City of
Los Angeles,California
Submitted forApproval
Contact usfor test data
1-800-328-5934 • www.USPconnectors.com8
©C
op
yrigh
t2011
US
PS
tructu
ralCo
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com
Corrosion Information
Connectors, including anchors and fasteners,installed in corrosive environments or exposed tocorrosive materials, or chemicals, can be damagedpossibly resulting in the reduction of load capacity.The selection of the proper connector coating canbe a complicated task. Environments can varygreatly regionally and are also influenced by variables such as fertilizer, animal waste, and wetcycle durations. If an electrolyte is present, such aswater, a metal will form an electric circuit with a dissimilar metal and galvanic corrosion can takeplace. Zinc is the metal used in the hot-dip galvanizing process due to its ability to sacrificeitself while protecting the base steel underneath.When the zinc and copper are in electrical contactwith each other the copper will have a tendency toextract electrons from the highly reactive zinc at agreater rate, therefore corrosion will take place at agreater rate. That being the case it is impossible to prescribe a reasonable uniform solution which willserve all environments adequately.
Chemical producers in the treated wood industryagreed to discontinue the use of ChromatedCopper Arsenate (CCA) for most residential applications at the end of 2003. In place of CCA,treated wood suppliers use copper based alternative treatment chemicals. Testing conductedby USP and others in the industry have concludedthe ACQ and Copper Azole wood treatments aremore corrosive to metals than traditionally usedCCA treatments are.
Recently some wood preservative manufacturershave introduced new wood preservative formulations.
These formulations include new micronized copperproducts as well as carbon based PTI woodpreservatives. USP Structural Connectors currently offers four different corrosion resistant finishes to cover arange of corrosion performance:
Triple Zinc (TZ) – galvanizing provides a prefabrication coating of 1.85 (G-185) ounces of zinc per square foot of surfacearea measured in accordance with ASTM A 653.
Required Fastener: Hot-dip galvanized fasteners
Hot-Dip Galvanized (HDG) –coating provides an after-fabrication hot-dippedzinc coating. The coating thickness is dependenton the connector material, but generally ranges from 1.1 to 2.3 ounces of zinc persquare foot of surface. Hot-dip products meetrequirements set forth in ASTM A 123.
Require Fastener: Hot-dip galvanized fasteners
Gold Coat (GC) – Gold Coat is a proprietary multi-layer protection system. It is comprised of anorganic top coat barrier layer and a zinc layerplaced over a steel substrate.
Required Fastener: Gold Coat fasteners
Stainless Steel – is the best option for corrosion protection. Quality stainless steel (316SSgrade steel) is used to fabricate connectors.Although costs are higher, some applications mayneed the virtual corrosion proof quality of stainlesssteel.
Required Fastener: Stainless Steel fasteners
Triple Zinc G-185
Hot-Dip Galvanized
Gold Coat
AWPA Use Service Use Example Preservatives and Minimum CoatingCategory Conditions Environment Applications Retentions6,7 Requirements 1,2,3,4
UC1 Interior construction, Continuously protected from General framing,Above ground, weather or other sources of interior construction Untreated G90Dry moisture
UC2 Interior construction, Protected from weather, but may be Sill plates SBX-DOT, Organic G90Above ground, subject to sources of moisture ACQ-D (0.25), CA-B (0.10), Triple Zinc (G-185)8,9
Damp CA-C (0.06), MCQ (0.25),µCA-C (0.05)
UC3A Exterior construction, Exposed to all weather cycles, not Exposed exterior beams ACQ-D (0.25), MCQ (0.25), Triple Zinc (G-185) orAbove ground, exposed to prolonged wetting or columns in an open, CA-B (0.10), CA-C (0.06), USP Gold CoatRapid water runoff covered structure µCA-C (0.05), Organic
UC3B Exterior construction, Exposed to all weather cycles, Deck beams and joists ACQ-D (0.25), MCQ (0.25), Triple Zinc (G-185) orAbove ground, including prolonged wetting CA-B (0.10), CA-C (0.06), USP Gold CoatPoor water runoff µCA-C (0.05), Organic
UC4A Exterior construction, Ground contact or fresh water Deck posts ACQ-D (0.40), MCQ (0.40), Triple Zinc (G-185) orGround contact, exposed to all weather cycles CA-B (0.21), CA-C (0.15), USP Gold Coat5
General use µCA-C (0.14)UC4B Exterior construction, Ground contact, fresh or salt water Permanent wood ACQ-D (0.60), MCQ (0.60), Stainless Steel
Ground contact, exposed to all weather cycles foundations, critical CA-B (0.31), CA-C (0.25),Critical structural structural members µCA-C (0.23)
Notes:1. G90 and G185 refer to galvanization requirements for ASTM A653 material.2. Connectors galvanized to ASTM A123 may be used in place of either G90 or G185 coatings.3. Other coating may be suitable for a given environment if the conditions are known and predictable. 4. For G90 or G185 connectors use fasteners galvanized per ASTM A153. For Gold Coat connectors use Gold Coat fasteners, and for stainless steel
connectors use stainless steel fasteners.5. If the environment has the potential to contain elements which may make it more corrosive, the use of stainless steel is recommended.6. MCQ is a micronized copper treatment such as Micro Pro by Osmose. µCA-C is a dispersed copper treatment manufactured by Arch Treatment Technologies.
Organic preservatives include L3 from Arch Treatment Technologies and EcoLife II from Viance, LLC.7. For wood treatments not shown contact USP or the wood preservative manufacturer for recommended coatings.8. Testing by USP has found that in interior applications where the treated wood will remain relatively dry during its service life the use of G90 connectors with
MCQ or µCA-C treated wood is appropriate.
Structural Connectors Coating Recommendations
USP2173-111
1-800-328-5934 • www.USPconnectors.com 9
©C
op
yrig
ht
2011
US
PS
tru
ctu
ralC
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com
Corrosion Information
www.USPconnectors.com
• Nails: (8) 10d x 1-1/2˝ HDG.
• As a minimum, recommendedin outdoor applications andwith treated wood.
A3-TZRef #: A23Z
Corner Angle1-7/16˝x 1-7/16˝x 2-3/4˝
For use withtreated wood
Para
MaderaTratada
Bin Card
Product Label
Carton Label
USP recommendation andstandards that are met withthe Triple Zinc coating.
Part number is referenced with a TZat the end for Triple
Zinc products.
Part number is referenced with
a TZ at the end for Triple
Zinc products.
USP recommendationand standards met with Triple
Zinc coating.
Part number is referencedwith a TZ at the end forTriple Zinc products.
Triple Zinc G-185 isreferenced abovethe bar code.
Light green backgroundcolour indicates a corrosionresistant product.
Yellow oval boldlyhighlights “for usewith treated wood”
TZ - Triple Zinc logo identifiesproducts that have G-185 galvanization.
The structural connectors coating recommendations chart onpage 8 has been developed by reviewing both field service performance and accelerated corrosion testing results. Whileaccelerated corrosion testing is a valuable tool to help predictrelative performance, both the particular testing method usedby the industry and the different wood treatment products tested are relatively new and there is little actual field servicelife data to correlate to the test results. In addition, actual service environments are much more complicated than accelerated tests. In accelerated tests influencing variablesare typically minimized and manipulated to cause reactionsto occur more quickly. Consequently this may result in reactions which are not completely representative of actualservice conditions. Because of this it is difficult to assign anexpected service life to a given coating in an environmentbased on the results of accelerated testing.
The formulations used by wood preservative manufacturersare constantly changing and improving. USP StructuralConnectors continues to test new wood treatments as theybecome available and will continue to update its recommendation as appropriate.
Corrosion Protection Guidelines:• USP recommends stainless steel connectors for the highest level of corrosion protection. As an economical alternative to stainless steel our new Gold Coat connectorsare specifically designed for exterior application when in contact with preservative treated wood.• Triple Zinc G-185 connectors are available as an economical alternative for exterior applications which willprovide a minimum level of protection.• The use of correct fastener with the connector is critical.Stainless steel connectors require stainless steel fasteners.For exterior applications, hot-dip galvanized fasteners (HDG)must be used with both Triple Zinc and Hot-dip galvanized finishes. Gold Coat connectors require gold coat fasteners.• USP’s zinc dichromate WS Wood Screws are not recommended for use with preservative or fire-retardant treated wood. Some wood screws are available in Gold Coat.• USP Structural Connectors clearly differentiates standard G90 connectors from the corrosion resistant connectors. Gold Coat connectors are distinguishable fromother connectors because of their concealing color.Examples of our carton labels, bin cards for retail displays,and individual product labels are found below.
1-800-328-5934 • www.USPconnectors.com
1-800-328-5934 • www.USPconnectors.com10
©C
op
yrigh
t2011
US
PS
tructu
ralCo
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Product Information
Then Hip/Valley Rafter Roof Pitchbecomes . . .
Gauge Inches MillimetersUncoated
SteelGalvanizedSteel (G90)
Triple Zinc(G-185)
3 1/4 6.0 0.238 -- -- -- --
7 3/16 4.5 0.171 0.186 -- --
10 9/64 3.4 0.129 0.138 0.14011 1/8 3.0 0.114 0.123 0.125
12 7/64 2.7 0.099 0.108 0.11014 5/64 2.0 0.070 0.078 0.080
16 1/16 1.5 0.055 0.063 0.065
18 3/64 1.2 0.044 0.052 0.05420 1/32 1.0 0.033 0.040 0.042
22 1/32 0.8 0.029 0.033 0.036
*Actual steel dimensions will vary from nominal dimensions according to industry tolerances.
ApproximateDimensions
Decimals (inches)
0/12 Flat1/12 5
2/12 10
3/12 14
4/12 18
5/12 23
6/12 27
7/12 30
8/12 349/12 37
10/12 40
11/12 42
12/12 45
Rise / Run(inches)
Slope(degrees)
1/12 5 1/17 32/12 10 2/17 7
3/12 14 3/17 10
4/12 18 4/17 13
5/12 23 5/17 16
6/12 27 6/17 19
7/12 30 7/17 228/12 34 8/17 25
9/12 37 9/17 28
10/12 40 10/17 30
11/12 42 11/17 33
12/12 45 12/17 35
1) Use this conversion table only for hip/valley rafters that areskewed 45° right or left. All other skews or dual pitch roofswill cause the slope to change from that listed above.
Rise / Run(inches)
Slope(degrees)
Rise / Run(inches)
Slope(degrees)
If common RafterRoof Pitch is . . .
SlopeConversion Table
100% 115% 125% 100% 115% 125% 100% 115% 125% 100% 115% 125%
DF-L 630 725 788 990 1139 1238 1305 1501 1631 1665 1915 2081
SP 613 704 766 963 1107 1203 1269 1459 1586 1619 1862 2023
S-P-F 473 544 590 743 854 928 979 1126 1223 1249 1436 1561 Hem Fir 525 604 656 825 949 1031 1088 1251 1359 1388 1596 1734
1) Applies to nominally dimensioned joists as listed, where moisture content < 19% andtemperature <100° F.
2) Loads apply to:DF-L: Douglas Fir-Larch (G=0.50), Fv=180 psi;SP: Southern Pine (G=0.55), Fv=175psi;S-P-F: Spruce-Pine-Fir (G=0.42), Fv=135psi;Hem Fir (G=0.43), Fv=150psi.
3) 115% and 125% loads are increased for short-term loading in accordance to the code.
Allowable Shear on Bending Member1,2,3
Joist or Rafter
WoodSpecies
2 x 4 2 x 6 2 x 8 2 x 10
Roof Pitch
Maximum Shear Capacityof Joist or Rafter
U.S. Standard Steel gauge Equivalents in Nominal Dimensions
The table below indicates the calculated shear capacity of differentdimensional lumber sizes for various wood species.
Special & Custom Connectors
USP is committed to meeting every need youhave and we understand that stock connectorswill not meet all application or design requirements. Our Technical AssistanceRepresentatives will work with you to developand fabricate the Special or Custom connectoryou need.
What is the difference between a “Special”and a “Custom” connector?
A “Special” is a stock USP connector that ismodified within the limits listed in the SpecialtyOptions chart.
A “Custom” is a connector that does not closelyresemble a stock or special part offered in ourcatalog. Also, a “Custom” connector may be astock connector that is modified outside of thelimits listed in the Specialty Options charts or isnot listed in the catalog as having a specialtyoption available. Product drawings must be provided by the customer and will be manufactured by USP in accordance to customer specifications.
A full range of shipping options are availablefrom regular freight to overnight delivery.
37°
1 5/8˝
7˝
1 5/8˝
41º
(9)
23º
3/16˝
1 5/8˝
4 1/16˝
22˝
Special Order detail
Custom Order detail
USP2173-111
1-800-328-5934 • www.USPconnectors.com 11
©C
op
yrig
ht
2011
US
PS
tru
ctu
ralC
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Product Notes
ISO 9001 Certified
USP Structural Connectors®in Montgomery, Livermore, and Largo,
achieved registration of its quality management system in accordance with the requirements of
ISO 9001
1) This catalog reflects the most current information regarding USP product line. However, product revisions andnew product additions occur on an ongoing basis. USPStructural Connectors® reserves the right to change specifications, designs, and models at any time withoutnotice and liability for such changes. This catalog may not bereproduced in whole or in part without the prior writtenapproval of USP Structural Connectors®.
2) This catalog reflects design changes and design loadadjustments to some USP products. The information presented in this publication replaces all information published in previous documents, and is valid until December 31, 2011.
3) This Full Line Catalog was designed as a general reference for the USP Product Line. Various specialized publications have been developed for design professionals,truss manufacturers, contractors, retail dealers, and buildingmaterial wholesalers. Product load values may vary from onepublication to another due to recent product testing, changesin regulatory criteria, or code evaluation updates. The mostcurrent product information is available on USP’s Web Site.
4) The type and quantity of fasteners used to install USPproducts is critical to connector performance. To achieve theallowable loads presented in this catalog, all specified fasteners must be used and proper installation proceduresobserved. Verify that the dimensions of supporting membersare sufficient to receive specified fasteners. Any productmodifications void the warranty unless prior written permission of USP Structural Connectors® is obtained.
5) Some connector models are listed more than once to indicate installation and/or fastener options.
6) New products or updated product information are designated in red.
7) Throughout this catalog, dimensions are expressed ininches and loads in pounds unless specifically noted otherwise.
8) Some USP products show both bolt and nail fasteningschedules. In those cases, specific loads for each has beenidentified. Bolt and nail values cannot be combined unlessnoted otherwise.
9) Load values for 8d, 10d, 16d, and 20d designations in thefastener schedules throughout this catalog refer to commonwire nails unless noted otherwise. Nails shall conform to arecognized national standard, such as ASTM F1667, as prescribed by the model building codes.
10) Fastener installation may cause wood to split and reducea fastener’s ability to carry a load. If wood splitting occurs,consider pre-drilling holes not exceeding 75% of the naildiameter (per the National Design Specification).
11) Bolts specified in this catalog are through-bolts and mustconform to requirements for ASTM A 307 Grade A, or ASMESAE Grade 2, or better unless noted otherwise.
12) Anchor Bolts conform to ASTM F 1554.
13) USP connectors listed in this catalog are manufacturedfor specific sizes of standard lumber, plated trusses, or composite lumber. For applications involving unusual supporting conditions environments, contact USP. Woodshrinkage or expansion, caused by lack of moisture or excessive moisture, may adversely affect connector installation. Evaluate potential shrinking or expanding toensure proper connector installation and performance.
14) The load values listed in this catalog are based on installation to wood with a moisture content of less than 19%,and used in dry service conditions. Load reductions, in accordance with the code, shall be taken where wood moisture content greater than 19% at the time of installationor where used in wet service conditions.
15) Unless otherwise noted, USP products may not be bentor cut in the field to facilitate installation. Field alterations mayweaken steel and cause connector failure at lower than published allowable loads.
1-800-328-5934 • www.USPconnectors.com12
©C
op
yrigh
t2011
US
PS
tructu
ralCo
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
1) Allowable loads for more than one direction for a singleconnection cannot be added together. A design load whichcan be divided into components in the directions given mustbe evaluated as follows:Design shear/allowable shear + design tension/allowable tension < 1.0
2) The allowable loads shown in this catalog are based onAllowable Stress Design methodology. AF&PA has publisheda brochure for calculating soft conversions called Guideline toLRFD for Pre-engineered Metal Connectors for WoodConstruction. Consult USP for assistance in determiningappropriate LRFD values for the products shown in this catalog.
3) Connector ratings may exceed the tensile strength or otheraspects of the wood members involved in the connection. A qualified designer should verify wood member capacitieswhen specifying connectors.
4) Verify that the size of the supporting member can accommodate the connector’s specified fasteners.
5) Some illustrations in this catalog may not reflect additionalmechanical reinforcements which may be required to reducecross grain tension or wood member bending under loading.The design professional is responsible for determining if additional mechanical reinforcement is required.
6) USP recommends the hanger height be 60% of the joistheight for stability.
NDS® StandardsUnless otherwise noted, the load resistance values presented in this catalog reflect the calculation criteria setforth in the 2005 National Design Specification for WoodConstruction (NDS®) published by the American Forest andPaper Association; with the methodology prescribed in ICC-ES AC13 or other relevant acceptance criteria applied.
MaterialUSP selects steel for its various products in accordance withapplication needs and steel properties, including tensilestrength, ductility, corrosion resistance, gauge, and weldability. See specific code evaluations or consult USP forsteel information on specific products. USP StructuralConnectors® are manufactured from steel which meetsASTM A 653, ASTM A 1011, or ASTM A 36.
Testing and Product Design LoadsOn all structurally-rated products, USP performs full-scaletesting in accordance with ICC-ES AC13, or ASTM D 1761,the standard recognized by all domestic model code agencies. All final testing is conducted by a third-party testinglaboratory. In accordance to these standards the designloads listed are the lowest results obtained from one of thefollowing methods:
1) The lowest ultimate tested load divided by three.2) Lowest load producing 1/8˝ deflection.3) Calculations based 2005 NDS® and current codes.
The listed capacity of some products have been increased inaccordance with the NDS® by applying Duration Factors formechanical fastenings. Stress increases have not beenapplied to steel components of the products.
Floor / Design Load .......100% (no increase).Roof Snow .....................115% of design load for 2-month
duration of load.Roof Non-Snow .............125% of design load for 7-day
duration of load.Uplift...............................160% of design load for
wind/seismic loading based on local code requirements.
Spruce-Pine-Fir or Hem Fir Equivalent CapacityUnless otherwise noted, the published design loads in thiscatalog apply to Douglas Fir-Larch or Southern Pine lumber.When Spruce-Pine-Fir or Hem Fir lumber is used with facemount hangers or straps, the nail shear capacity maybeadjusted according to the chart below.
Design Notes
Douglas Fir-Larch (DF-L) 0.50 1.00
Southern Pine (SP) 0.55 1.00
Spruce-Pine-Fir (S-P-F) 0.42 0.86
1) Allowable loads must be adjusted according to theapplicable wood species.
2) When using structural composite lumber, verify wood speciesand use above listed adjustment factors.
Douglas Fir (S)Hem Fir (N)
0.46 0.88
Allowable Load Adjustment Factor
WoodSpecies
SpecificGravity
AdjustmentFactor
Download
Uplift
Lateral
Out
F1
F1
F2
F2 or F3
Perpendicular
1) Use proper safety equipment during connector installations. Always wear gloves when handling connectors.
2) All field welding should be done in accordance with AWSCodes. Caution: Welding galvanized steel may produceharmful fumes and should only be performed in well-ventilated environments.
3) The type and quantity of fasteners used to install USPproducts is critical to connector performance. To achieve theallowable loads shown in this catalog, install with the fasteners specified for that particular product. Some productsallow for alternate nail installations. Refer to the “OptionalNails for Face Mount Hangers and Straight Straps” chart onpage 22 of this catalog for load adjustments when using alternate nailing. All specified fasteners must be properlyinstalled prior to applying load of any kind to the connection.
4) Drill bolt holes a minimum of 1⁄32˝ and a maximum of 1⁄16˝larger than the diameter of the bolt to be installed (per the2005 NDS®, Section 11.1.2.).
5) Washers should always be used under the head or nut ofa bolt when not in contact with the connector unless notedotherwise.
6) It is permissible to use nail guns to install connectors aslong as the specified nails are installed through prepunchednail holes and all specified nail holes are filled. USPrecommends the use of nail guns featuring hole-locatingmechanisms. Please note that many nail guns use fastenerssmaller than the common nail size and load reductions willresult. Contact USP or visit our Web Site for additional information. Caution: Always follow nail gun manufacturer’ssafety guidelines.
7) Joists installed in hangers should bear fully on the connector seat and shall be cut to fit against the header witha gap no greater than 1⁄8˝ between the joist end and headerface. Refer to Face Mount Hanger Gap Testing TechnicalBulletin.
8) Multiple-ply members must be fastened securely togetherto act as one member.
9) Top mount hangers shall be installed with the face of thehanger tight to the face of the header.
10) Top mount hangers installed in floor systems may produce unevenness. This may vary by the thickness of thehanger top flange steel and the nail heads. If a problem isanticipated, the effects can be mitigated by dapping the beamor cutting the subfloor at hanger locations. The use of facemount hangers will eliminate this problem.
USP2173-111
1-800-328-5934 • www.USPconnectors.com 13
©C
op
yrig
ht
2011
US
PS
tru
ctu
ralC
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Installation Notes
Nails. . . . . . . . . . . . . . . . . . . . . . Pages 15-16• NA SeriesUSP structural nails and common nail design information.
Bearing Plates . . . . . . . . . . . . . . . . . Page 17• BP SeriesStandard bearing plates.
• HBPS/LBPS SeriesSlotted bearing plates.
• LBP SeriesGalvanized standard bearing plates.
Wood Screws . . . . . . . . . . . . . . Pages 18-21• WS SeriesUSP self-drilling wood screws.
• Wood Screw ApplicationsInformation on joining multiple ply truss, LVL, or PSL members.
LumberLok Screws . . . . . . . . . Pages 22-23• LL SeriesSelf-drilling screws for a number of USP Structural Connectorsand wood-to-wood applications.
BP/LBP
LL
NA
WS
Faste
ners
1-800-328-5934 • www.USPconnectors.com14
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
HBPS/LBPS
Fasteners
USP2173-111
Faste
ners
1-800-328-5934 • www.USPconnectors.com 15
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Proper fasteners are a critical component in a sound wood frame structure. To ensure successful installations of itsconnectors, USP offers a full range of structurally-rated nails. All galvanized nails supplied by USP are Hot-dipped forgreater corrosion resistance. Any USP connector requiring a NA16D-RS or NA20D nail is shipped with the nailsattached to the connector in convenient poly bags.
Finish: See chartMaterials: ASTM A 123; ASTM A 153 (HDG)
Installation:• Allowable shear values assume nail embedment into the wood of the entire nail or 10 nail diameters (whichever isless). Otherwise, the nail must be embedded at least 6 nail diameters, with the load reduced using the equation below:
Reduced Load = Published Load x Actual PenetrationNail Diameter x 10
• Load reductions may occur if nails are used other than those specified. See the chart Optional Nails for Face MountHangers and Straight Straps on page 16 for load reduction factors regarding nail substitutions.• For pneumatic nail use, see Installation Notes on page 13 and reference USP’s technical bulletins.
Nails – NA series
6d 11-1/2 .113 1.13 0.68 8d 10-1/4 .131 1.31 0.79
10d 9 .148 1.48 0.89 12d 9 .148 1.48 0.89
16d Sinker 9 .148 1.48 0.89
16d 8 .162 1.62 0.97 20d 6 .192 1.92 1.15
1) Less than the specified nail penetration shall be multiplied by the applicable adjustment factor. 2) For penetration less than this distance, the nail has no value. 3) Penetrations are derived according to the 2005 NDS®.
MinimumPenetration for
Reduced Shear Load2
(inches)
MinimumPenetration forFull Shear Load
(inches)
NailPenny
WireGauge
ShankDiameter(inches)
Ref. No. Finish4Description Length 3 7 10 12 14 16 18 20 22
NA11 N8 HDG 8d x 1-1/2 0.131 1-1/2 48 152 -- -- -- -- -- -- -- -- -- -- 96 95 94 94 N8-GC -- -- GC 8d x 1-1/2 0.131 1-1/2 48 152 -- -- -- -- -- -- -- -- -- -- 96 95 94 94
NA9D N10 HDG N10-GC -- -- GC
NA16D N16 HDG 16d x 2-1/2 0.162 2-1/2 99 66 192 177 158 147 140 138 136 136 -- --
NA16D-RS -- -- Bright 16d Ring Shank 0.148 3-1/2 140 47 181 164 147 -- -- -- -- -- -- -- -- -- -- -- -- NA20D -- -- HDG 20d x 2-1/2 0.192 2-1/2 117 41 231 202 184 174 167 -- -- -- -- -- -- -- --
8d Common -- -- Bright 8d Common 0.131 2-1/2 80 126 -- -- -- -- -- -- -- -- 98 96 95 94 94 10d Common -- -- Bright 10d Common 0.148 3 108 70 -- -- 154 136 125 118 115 114 113 112
N10C-GC -- -- GC 10d Common 0.148 3 108 70 -- -- 154 136 125 118 115 114 113 112 16d Sinker -- -- Bright 16d Sinker 0.148 3-1/4 117 60 160 154 136 125 118 115 114 113 -- --
N16C-GC -- -- GC 16d Common
16d Common -- -- Bright 16d Common 20d Common -- -- Bright 20d Common 0.192 4 187 29 231 202 184 174 167 -- -- -- -- -- -- -- --
1) Loads are calculated according to specifications of Part II of the National Design Specifications for Wood Construction (NDS®), 2005 Edition. 2) Loads apply to Douglas Fir-Larch (G=0.50) and Southern Pine (G=0.55). For Spruce-Pine-Fir (G=0.42) multiply above values by 0.86, for other wood types refer to NDS® or consult USP. 3) Shear values assumes full penetration of at least 10 nail diameters. 4) HDG = Hot-Dip Galvanized; GC = Gold Coat; Bright = No Finish. 5) For steel with Fu=45,000 psi, and gage minimum bare metal thickness. 6) Fastener values may be increased for duration of load. 7) Withdrawal loads assume full penetration.
14748 192 177 158
USPStock No.
NailDiameter
Withdrawal
Load7
0.162 3-1/2 138
111
Allowable Shear per Nail (Lbs.)1,2,3,5
Steel GaugeNailsPer Lb.
10d x 1-1/2 1140.148 1-1/2 54 100 118 -- -- 126 -- -- 112 112 112
-- --140 138 136 136
Minimum Fastener Penetration table
Nail Specification table
continued on next page
Reduced Fastener PenetrationExample (See chart on left):
HD210 – listed load is 1690 lbs. @100% for 16d common nails.
Reduced HD210 capacity if using a2x DF-L or SP header:
1690 lbs. x 1.5 = 1565 lbs. @ 100%1.62
!
How to Use:The base value is the catalog listed nail in Douglas Fir-Larchand the adjustment factor is the multiplier for the applicable replacement nail and wood combination.
• Adjustment factors may vary with some custom hangers orsteel thicker than 10 gauge. Contact USP for exceptions.• Roofing nails shall not be substituted for any nail size or type.
Faste
ners
1-800-328-5934 • www.USPconnectors.com16
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Nails – NA series continued
Optional Nails Example:
JL210 – listed load is 1595 lbs. @100% for 10d common nails.
If substituting:8d common nails with DF-L or LVL:1595 lbs. x .83 = 1323 lbs.
8d common nails with SP:1595 lbs. x .90 = 1435 lbs.
8d common nails with S-P-F:1595 lbs. x .72 = 1148 lbs.
No further reductionsare required.
Optional Nails for Face Mount Hangers (excludesslant nail hangers)
NA16D-RS NA16D NA9D NA11NA20D.192 x 2 1/2˝ .148 x 3 1/2˝ .162 x 2 1/2˝ .148 x 1 1/2˝ .131 x 1 1/2˝
DF-L SP S-P-F LVL
16d common 8d common 0.70 0.75 0.60 0.70 16d common 10d Box 0.67 0.72 0.58 0.67
16d common 10d common 0.83 0.91 0.72 0.83 16d common 12d common 0.83 0.91 0.72 0.83
16d common 10d x 1-1/2 0.81 0.88 0.70 0.81
16d common 10d Sinker 0.59 0.64 0.51 0.59 16d common 16d Box 0.74 0.80 0.64 0.74
16d common 16d Sinker 0.83 0.91 0.72 0.83 16d common 16d x 2-1/2 1.00 1.00 0.86 1.00
16d common No. 8 x 1-1/2 Wood Screw 0.60 0.66 0.52 0.60
10d common 8d Box 0.63 0.68 0.54 0.63 10d common 10d Sinker 0.70 0.77 0.61 0.70
10d common 8d common 0.83 0.90 0.72 0.83 10d common 10d Box 0.80 0.87 0.70 0.80
10d common 8d x 1-1/4 0.64 0.69 0.55 0.64
10d common No. 8 x 1-1/2 Wood Screw 0.72 0.79 0.63 0.72 10d common 10d x 1-1/2 0.97 1.00 0.84 0.97
10d common 16d Sinker 1.00 1.00 0.86 1.00
10d common No. 8 x 1-1/2 Wood Screw 0.72 0.79 0.63 0.72 12d common 10d x 1-1/2 0.97 1.00 0.84 0.97
12d common 16d Sinker 1.00 1.00 0.86 1.00 12d common No. 8 x 1-1/2 Wood Screw 0.72 0.79 0.63 0.72
8d common 8d Box 0.75 0.81 0.65 0.75
8d common 8d x 1-1/4 0.76 0.83 0.66 0.76 8d common No. 8 x 1-1/2 Wood Screw 0.86 0.95 0.75 0.86
8d x 1-1/2 8d x 1-1/4 0.76 0.83 0.66 0.76 8d x 1-1/2 No. 8 x 1-1/2 Wood Screw 0.86 0.95 0.75 0.86
10d x 1-1/2 8d x 1-1/2 0.86 0.93 0.74 0.86
10d x 1-1/2 No. 8 x 1-1/2 Wood Screw 0.74 0.81 0.64 0.74
1) No. 8 x 1-1/2 Wood Screw has a shank diameter of 0.164˝ and shall conform to ANSI/ASME Standard B18.6.1-1981. 2) This chart does not apply to HUS, JDS, JH, JPF, JUS, MSH, MUS or THDH slant nail hangers.New products or updated product information are designated in bold font.
CatalogNail
Replacement
Fastener1
Allowable Load Adjustment Factor
!
N8-GC.148 x 1 1/2˝
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
L
W
PT
BP/LBPStandard
Bearing Plate
Typical BearingPlate installation
HBPS/LBPSSlotted Bearing Plate
BP – Designed to meet code requirements for mudsill-to-foundation.
HBPS/LBPS – Offers anchor bolt adjustment slots.
LBP – Galvanized finish for corrosion resistance.
Materials: See chartFinish: BP & HBPS – none;
LBP & LBPS – G-185 galvanizingOptions: BP12, BP583 & HBPS12 models are available in
Hot-dip galvanized. To order, add HDG to end of stock number, as in BP12-HDG.
Installation:• Bolt holes are sized 1⁄16˝ larger than Bolt Dia. shown in chart.
Bearing Plates – BP, HBPS, LBP, & LBPS series
Ref. No. W L
LBP12-TZ LBP1/2, LBP1/2Z
10 Ga 2 2 1/2 120
LBP58-TZ LBP5/8, LBP5/8Z
10 Ga 2 2 5/8 100
LBPS12-TZ LBPS1/2, LBPS1/2Z
10 Ga 3 3 1/2 120
LBPS58-TZ LBPS5/8, LBPS5/8Z
10 Ga 3 3 5/8 120
HBPS12 BPS1/2-3 3 Ga 3 3 1/2 100
HBPS34 BPS3/4-3 3 Ga 3 3 3/4 100 HBPS58 BPS5/8-3 3 Ga 3 3 5/8 100
BP12 BP1/2 7 Ga 2 2 1/2 100 BP582 BP5/8-2 7 Ga 2 2 5/8 100
BP583 BP5/8-3 3 Ga 3 3 5/8 100
BP343 BP3/4-3 3 Ga 3 3 3/4 100
CodeRef.
USPStock No.
BoltDia.
DimensionsPlateThickness
(PT)
In some applications the code requires specific size plate washers be provided between the foundation sill plate and
the nut. IRC R602.11.1, IBC 2308.12.8.
WL
USP2173-111
Faste
ners
1-800-328-5934 • www.USPconnectors.com 17
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
Faste
ners
1-800-328-5934 • www.USPconnectors.com18
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Wood Screws – WS series
Ref. No. Description L SH T Finish114 Ga 10 Ga 7 Ga 3 Ga 100% 14 Ga 10 Ga 7 Ga 3 Ga 100%
WS15 SDS25112 Zinc
WS15-GC -- -- GC WS2 SDS25200 1/4˝ x 2˝ 2 1/4 1-3/4 Zinc -- -- 306 307 289 316 160 -- -- 215 244 249 248 117
WS25 SDS25212 1/4˝ x 2-1/2˝ 2-1/2 1/4 2-1/4 Zinc 193 362 352 338 369 199 141 256 292 286 294 141
WS3 SDS25300 1/4˝ x 3˝ 3 3/4 2-1/4 Zinc 227 418 396 387 457 199 164 297 340 322 365 141 WS35 SDS25312 1/4˝ x 3-1/2˝ 3-1/2 3/4 2-3/4 Zinc 233 451 460 454 481 208 181 338 380 356 370 154
WS45 SDS25412 1/4˝ x 4-1/2˝ 4-1/2 1-1/4 3-1/4 Zinc 233 516 588 589 531 214 181 421 460 425 379 163 WS6 SDS25600 1/4˝ x 6˝ 6 1-3/4 4-1/4 Zinc 233 516 588 589 531 214 181 421 460 425 379 163
1) Zinc = Yellow Zinc Dichromate; GC = Gold Coat. 2) Allowable shear loads assume a side plate tensile strength of 45 ksi for 14 gauge and 10 gauge, 52 ksi for 7 gauge and 58 ksi for 3 gauge. 3) Shear loads for wood-to-wood connections assume a side member thickness of 1-1/2". 4) Loads are for 100% duration of load factors, and may be increased for other duration factors in accordance with the NDS. 5) Loads are for shear applications when used as described in this catalog. Please contact USP for applications and installations involving tension forces. 6) Withdrawal loads for steel-to-wood connections assume a side plate thickness of 1/4" or less. New products or updated product information are designated in bold font.
CodeRef.
12,F29
-- -- 230
Steel to Wood 6
WithdrawalCapacity
WithdrawalCapacity
Shear (100%)
Wood
to Wood3
Steel to Wood6
S-P-F2,4,5Dimensions
USPStock No.
Wood
to Wood3
DF-L / SP2,4,5
Shear (100%)
1/4˝ x 1-1/2˝ 1/2 1/4 1-1/4 103261 259 164 190 217266 -- -- 188 211
The WS Wood Screw is a self-drilling screw used for numerous framing applications. This screw features a reverse locking serration on the bottom ofthe screw head to help prevent over tightening against a steel plate. The USPhead stamp identifies screws for easy inspection.
Screw shear capacities are based on a diameter of 0.242˝ when the shear planeis on the screw shank (SH) and 0.185˝ when the shear plane is on the knurl orthreads (T). USP WS Wood Screws have a bending yield strength of 217,000psi. For conditions not charted here, screw loads may be calculated as shownin the NDS® and increased for duration of load.
Materials: 1/4˝ diameter Grade 5 steelFinish: See chartCodes: ESR-2761, FL13170
Installation:• Screws are self-drilling.• Install using a low speed clutch drill with 3/8˝ hex head driver. The washerhead should be flat to the surface and the serrations will oppose turning andrelease the clutch. Do not over-tighten the screws.• Installing the screw at an angle may introduce additional bending and tensionforces into the fastener if the screw head is not flat on the bearing surface. Careshould be given to ensure the fastener is installed perpendicular to the plane ofthe side plate.
For Attaching Multi-Ply Wood Trusses orLVL or PSL members, or floor trusses,
see pages 19-21.
3/8˝
USP name Screw length
Serrations
Beveled reamer on2 1/2˝ or longerWood Screws
Cut threads
Self drilling point
L
T
SH
WS
USP2173-111
Faste
ners
1-800-328-5934 • www.USPconnectors.com 19
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Installation:• Screw spacing shall not be greater than 24˝ on center and less than 4˝ on center. However, the location of any individual screw may be adjusted up to one-half the required screw spacing to avoid lumber defects or interferencewith other hardware.• Load or hanger spacing shall not be greater than 24˝ center-to-center.• The last truss ply must have a minimum of 11/4˝ of screw penetration and no more than 1/8˝ gap between each ply.• Screws cannot be installed through metal truss plates unless the Truss Engineer approves predrilling.• On 2x4 members, use one row of wood screws. On 2x6 and 2x8 use two rows, and on 2x10 use three rows. Staggerall rows.• The truss bottom chord shall have lateral bracing installed as called out by the Truss Engineer to prevent any displacement from torsional forces.• Install screws from one sidewithout flipping the truss.• Top and bottom chordsrequire screws and in somecases the webs may requirescrews.• All lateral bracing should beattached to each truss ply.• Increase edge and end distances if wood splittingoccurs.
Wood Screw Applications – WS series
Floor Floor Floor
Ref. No. Description L SH T Finish 100% 115% 125% 100% 115% 125% 100% 115% 125%
WS3 SDS25300 1/4˝ x 3˝ 3 3/4 2-1/4 Zinc SH, T 227 261 284 266 306 333 164 189 205
WS45 SDS25412 1/4˝ x 4-1/2˝ 4-1/4 1-1/4 3-1/4 Zinc SH, T 233 268 291 266 306 333 181 208 226
T 243 279 304 266 306 333 206 237 258SH 276 317 345 320 368 400 211 243 264
1) The Truss Engineer shall apply all adjustment factors required per 2005 NDS®. 2) Loads are based on 1-1/2˝ thick wood side members. Side and main members of same wood species. 3) SH = screw shank; T = threads. New products or updated product information are designated in bold font.
WS6
USPStock No.
1/4˝ x 6˝ Zinc4-1/46 SDS25600 1-3/4
Dimensions Allowable Shear Loads (Lbs.)1,2
RoofShearPlane
Location3
Douglas Fir-Larch(G = 0.50)
Roof
Spruce-Pine-Fir(G = 0.42)
Southern Pine(G = 0.55)
Roof
continued on next page
Typical Truss Profile (profile may vary)
3 Ply with Mixed Wood Species:Bottom Chord: 2x6 Southern PineTop Chord: 2x4 Spruce-Pine-Fir
Required Loads:Bottom Chord Load: 500 plf
Top Chord Load: 60 plf(Roof Live Load: CD = 1.15)
Bottom Chord Wood Screw Spacing:Using 2 rows of WS45 Wood Screws in 2x6
2 x 306/500 x # Plys = 1.84 ft.# Plys - 1
Use maximum spacing of 24˝.
Top Chord Wood Screw Spacing:Only 1 row of WS45 Wood Screws in 2x4 member
1 x 208/60 x # Plys = 5.20 ft.# Plys - 1
Use maximum spacing of 24˝.
WS45 Wood Screw Allowable Loads:(Assume shear plane across the screw shank)Southern Pine: 306 Ibs. each at 115%Spruce-Pine-Fir: 208 lbs. each at 115%
Design Example
Joining 2, 3, or 4 Ply Wood TrussesThe installation instructions and design example shown below are intended for a design professional who will beresponsible for determining the location and number of wood screws to adequately transfer all loads on the truss.
Truss top chord
Truss bottom chord
Truss span
2 1/2˝ Min.
1 1/2˝ Min.
1 1/2˝ Min.
Start screws onface that carries
hanger on load
Spacing4˝ min. – 24˝ max.
Spacing4˝ min. – 24˝ max.
1˝ min. Recommended (Typ)4˝ min End of
cord
Faste
ners
1-800-328-5934 • www.USPconnectors.com20
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Spacing4˝ min. – 24˝ max.
Spacing4˝ min. – 24˝ max.
End of member
1˝ min. Recommended (Typ)Other Stagger patterns as approved by Engineer are acceptable
1 1/2˝ min
4˝ min
2 1/2˝ min
2 1/2˝ min 1 1/2˝ min
H
Wood Screw Applications – WS series continued
Joining 2, 3, or 4 Ply LVL, LSL or PSL Members
Installation Notes:• For 2 ply members, wood screws shall be installed with the screw heads in the loaded ply.• For 3 or 4 ply members, wood screws shall be installed in both outer plys.• Designer shall specify all wood screws locations.• Increase edge and end distances if wood splitting occurs.• Stagger all screws installed into the opposite face.• A minimum of 2 rows of screws shall be used for all members with H = 5 1/2˝ and larger.
Ref. No. Description L SH T
1 970 1460 650 970 490 7302 730 1095 490 730 365 550
4 730 1095 490 730 365 5505 650 970 430 650 325 485
3 650 970 430 650 325 485
6 970 1460 650 970 490 730
USPStock No.
2Rows
3Rows
2Rows
MultipleMembers
Installation
Figure2
12˝ O.C. 18˝ O.C.
Wood Screw Spacing
3-1/2 1
Dimensions
3Rows
DF-L / SP
2Rows
3Rows
F24˝ O.C.
Maximum Allowable Uniform Loadsthat can be applied to either outsidemember (Lbs. Per Lineal Ft.)1,3,4,5,6
1-3/4 4-1/4
WS35
WS6 SDS25600 1/4˝ x 6˝ 6
SDS25312 1/4˝ x 3-1/2˝ 2-1/2
Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6
WS35 installed in (2) 13/4˝ Ply
WS35 installed in (3) 13/4˝ Ply
WS6 installed in (4) 13/4˝ Ply
WS35 installed in (1) 13/4˝,(1) 31/2˝ Ply
WS35 installed in (2) 13/4˝,(1) 31/2˝ Ply
WS6 installed in (2) 31/2˝ Ply
Recommended Row Guidelines
Serrations
Beveled reamer on2 1/2˝ or longerWood Screws
Cut threads
Self drilling point
L
T
SH
continued on next page
1) Based on Zscrew = 243 pounds in Douglas Fir-Larch with a side member thickness of not less than 1-3/4˝. 2) Load values depicted assume all uniform load is applied to the most narrow outside ply only. 3) Load values neglect any contribution of screws installed to opposite side, even if they extend significantly into the loaded ply. 4) Loads are for normal (100%) duration of load, and may be increased in accordance with the code. 5) Uniform loads in table represent the capacity of the fasteners. The capacity of the LVL or PSL beam may be less and should be checked by a qualified designer or with the manufacturer's literature. 6) A qualified designer shall ensure the adequacy of a 7˝ wide beam to resist the applied load on one edge; otherwise, the loads shall be uniformly distributed across the width or applied equally on both sides. 7) Wood screws longer than 3-1/2˝ are not recommended
for use with Parallam® PSL or TimberStrand® LSL.
8) For Figures 2, 3, 5, and 6: Stagger the screws on opposite
face by half minimum spacing requirements. New products or updated product information are designated
in bold font.
WS
Applied Concentrated LoadWS6 Wood Screw
USP2173-111
Faste
ners
1-800-328-5934 • www.USPconnectors.com 21
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Wood Screw Applications – WS series continued
Joining 2 Ply 4x2 Floor TrussesThe following information pertains to the use of the USP’s WS6 Wood Screws to fasten together a two-ply 4x2 floor trussgirder, such that the induced loads are supported by both truss plys. Screw spacing and the location of each specificscrew may vary depending on the design criteria for each application, and therefore must be determined by the truss orbuilding designer. However, in the determination of screw locations, the following criterion shall also be considered.These criterion are varying dependent upon how trusses are loaded as follows:
3 1/2˝
1 1/2˝
3 1/2˝ 5/8˝ - 7/8˝
Truss Members
WS6 Wood Screw
Typ. @ all members
Ref. No.
WS6 SDS25600 243 266 206
New products or updated product information are designated in bold font.
Allowable Shear Loads
USPStock No.
Floor(100%)
Floor(100%)
Floor(100%)
Douglas Fir-Larch(G = 0.50)
Southern Pine(G = 0.55)
Spruce-Pine-Fir(G = 0.42)
Applied Concentrated LoadAdditionalWS6 Wood Screw
if necessary12˝max
12˝max
Uniform/Distributed Load
Concentrated/Point Load
Uniform/Distributed Load
• Screws shall be installed into the top chord with a horizontalspacing between screws of not less than 4-inches on center andnot more than 24-inches on center.• A minimum end distance of 4-inches must be maintained. If
necessary, additional screws may be installed in the bottom chord.• Center screw vertically on 11/2˝ dimension of top chord. If
splitting occurs, it may be necessary to pre-drill the holes in accordance with the code.• The screws shall be installed with the headed end of the screw
on the loaded truss. If either ply is “the loaded truss”, the screwsshall be divided between the two plys, with the spacing on eachside twice the minimum indicated above.• The screws shall not be installed through the metal truss plates,
unless approved by the truss designer and the plates are pre-drilled, on each side to a 1/4-inch diameter. Do not drill throughthe wood.• The maximum gap between the wood members of the two
trusses shall be 1/8-inch.• The truss designer shall design the truss members with the
capacity and capability of the screws in mind, and shall meet allprovisions of the code and ANSI/TPI.• Individual screw locations may need to be adjusted to avoid
conflicts with connectors, problematic wood or other framing members. Adjustments should follow the criteria described in thissection.
Concentrated/Point Load
The placement of fasteners for concentrated loading includes allrequirements of uniform loading with the additional following criteria:
• Loads must occur over a vertical member, and the necessaryconcentration of screws shall be installed in the vertical member.• Additional screws may be installed on the top chord and
adjacent web members if necessary.• The fasteners should be grouped as close to the concentrated
load as possible, but satisfy the same minimum spacing indicated for uniform loading. • In no case shall the required group of fasteners extend beyond
12-inches from the location of the concentrated load.
Screw Detail
Applied distributed loadWS6 Wood Screws
Faste
ners
1-800-328-5934 • www.USPconnectors.com22
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com
Lumberlok Structural Connector Screws - LL series
Designed specifically for attaching wood connectors!
Replaces Nails! Structurally Rated.
Developed and tested to meet high load requirements. (Hightensile structural capacity)
Available in two sizes:#9 x 1 3/8˝ and #9 x 2 7/8˝.
Torx #20 head to eliminate stripping.
Self Tapping Shank Slot.
™
STRUCTURAL CONNECTOR SCREWS
continued on next page
USP2173-111
Faste
ners
1-800-328-5934 • www.USPconnectors.com 23
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®Lumberlok Structural Connector Screws - LL series cont.
1-800-328-5934 • www.USPconnectors.com
Ref. No. Description L SH T Finish118 Ga 16 Ga 18 Ga 16 Ga
LL915 SD9112 #9 (0.131") x 1-1/2 13/8 0.162 1 1/8 GC - - 121 105 131 - - 96 113 104
LL930 SD9212 #9 (0.131") x 3 27/8 0.162 1 1/2 GC 104 146 176 163 100 128 147 138
1) GC = Gold Coat over Clear Zinc Trivalent. 2) Allowable shear loads assume a side plate tensile strength of 45 ksi. 3) Withdrawal loads for steel-to-wood connections assume a side plate thickness of 1/4" or less. 4) Shear loads for wood-to-wood connections assume a side member thickness of 1 1/2". 5) Loads are for 100% duration of load factors and may be increased for other duration factors in accordance with the NDS. New products or updated product information are designated in bold font.
130
S-P-F Allowable Shear (Lbs.) 2,3,4,5
Steel-to-Wood Steel-to-Wood
CodeRef.
Wood-to-Wood
WithdrawalCapacity
USPStock No.
Dimensions (in.) DF-L / SP Allowable Shear (Lbs.)2,3,4,5
Wood-to-Wood
WithdrawalCapacity
The LumberLok Structural Connector Screw is a self-drilling screw that can beused with a number of USP Structural Connectors and also for wood-to-woodapplications. The screws feature a T20 Torx® head with integral washer andgimlet point for ease of installation. The twin-lead threads drive in twice as fastas the single lead threads significantly reducing installation time. The USPhead stamp identifies the screw length for easy inspection.
Screw shear capacities are based on a diameter of 0.162” when the shear planeis on the screw shoulder (SH) and 0.109” when the shear plane is on thethreads (T). USP LumberLok Structural Connector Screws have a bendingyield strength of 180,000 psi
Materials: Low carbon hardened steel.Finish: See chart
Installation:• Screws are self-drilling.• Install using a low speed clutch drill with T20 Torx® bit. The washer headshould be flat to the surface. Do not over-tighten the screws.• Installing the screw at an angle may introduce additional bending and tensionforces into the fastener if the screw head is not flat to the bearing surface. Careshould be given to ensure the fastener is installed perpendicular to the plane ofthe fastener hole.
NEW
LL915
LL930
Twin-leadthreads
Sharp Gimlet point
USP name
Screwlength
T20 Torx®head
L
SH
T
Con
cre
te &
Mason
ry
1-800-328-5934 • www.USPconnectors.com24
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
KGH
RP6
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
DUCSB
STB/STBL AB
Concrete & Masonry
ST1-TZ ST2-TZ FA3
FT WG
Adhesive & UndercutAnchoring Systems. . . . . . . . . . . Pages 25-27• DUC SeriesDuctile Undercut Anchors.
• CIA-EAHigh strength epoxy acrylate.
• CIA-GEL 7000High strength epoxy.
Anchor Bolt Stabber. . . . . . . . . . . Page 28• ABS12Anchor bolt stabber for placement in wet concrete.
Threaded Rods . . . . . . . . . . . . . . . . Page 28• THR SeriesThreaded Rod
Anchor Bolts . . . . . . . . . . . . . Pages 28-30• STB & STBL SeriesUSP anchor bolts designed for higher capacity
applications.
• AB SeriesUSP anchor bolts designed for general capacity
applications.
Concrete Form Ties& Wedge . . . . . . . . . . . . . . . . . . . . . Page 30• FT SeriesLow foundation wall tie.
• WGWedge for FT tie.
Foundation Anchors . . . . . . . Pages 31-32• ST SeriesEmbedded mudsill anchors.
• FA3 Embedded mudsill and stud anchors.
Laminated Beam Seats . . . . . . . . . . Page 33• KGLB, KGLBT, & KHGLB Series
Seats for beams bearing on concrete or masonry.
Floor Girder Hangers. . . . . . . . . . Page 34• KGH SeriesSecures girder beam to foundation wall.
Retro Plate . . . . . . . . . . . . . . . . . . . Page 34• RP6Oversized plate to distribute forces on masonry surface.
DUC
CIA-EA CIA-GEL 7000
ABS12
KGLBTKGLB KHGLB
THR
lbdc
db
hef
ho
USP2173-111
Con
cre
te &
Mason
ry
1-800-328-5934 • www.USPconnectors.com 25
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com
Installation:
Drill the hole toproper depth and diameter per specifica-tions using rotohammer and stop drill.
Clean the hole using ablow-out bulbor compressedair.
Insert theundercut bitand start therotohammer.Undercutting iscomplete whenthe stoppersleeve is fullycompressed(gap closed).
Clean the holeagain using ablow-out bulbor compressedair.
Insert anchorinto hole. Placesetting sleeveover anchorand drive theexpansionsleeve over the expansioncoupling.
Verify that thesetting mark is visible on the threadedrod above thesleeve.
Apply propertorque.
DUCUndercut Anchor
DUC UCB Undercut Drill Bit
Tension and Shear Capacities for DUCAnchors in f’c > 2,500 psi concrete
Mechanical anchor expanded into a hole that has been undercut at thebottom using an undercutting drill bit creating a true bearing type anchorthat performs like a cast-in-place headed anchor. Load is transferred intothe concrete through bearing, not friction like traditional expansionanchors. Excellent performance in seismic and dynamic loading conditions. Meets ACI 318-05 Appendix D (2006 IBC) requirements as acode anchor, including seismic loading, tension zone, and cracked concrete provisions.
Rod Materials: ASTM A36 (L Series), A193 Grade B7(H Series), or AISI 316 Stainless Studs
Anchor Body Materials: ASTM A 513 Type 5, or AISI 316 StainlessCodes: ESR-1970, L.A. City RR 25753, FL11748
1-800-328-5934 • www.USPconnectors.com
Undercut Anchoring Systems - DUC Ductile Undercut Anchors
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Expansion Drilled Hole Allowable Allowable
Rod Coupling Depth of Effective Anchor Tensile ShearDia. d b Dia. dc Stop Bit ho Embedment hef Length, lb Capacity, Ns Capacity Vs
DUC38-275L DUC38-275LT DUC38-400H DUC38-400HT DUC12-400L DUC12-400LT DUC12-500H DUC12-500HT DUC12-675H DUC12-675HT DUC58-450L DUC58-450LT DUC58-750H DUC58-750HT DUC58-900H DUC58-900HT DUC34-500L DUC34-500LT DUC34-1000H DUC34-1000HT
1) Allowable tensile and shear capacities are for anchors installed at standard edge distance and spacing in uncracked concrete in accordance with the 2003 and 2006 IBC (ACI 318-02 and 318-05). For cracked concrete capacities, see the USP Anchoring Systems Design Guide.
USP
Stock No.
9007 4497
19411 9692
4111
6086 3047
13116 6552
1043
4497 2254
3821 1909
5-1/2 2087
8235
6-3/4
7
8
9-3/4
12-1/4
8-5/8
13-5/8
7-3/4
10-3/4
9
5
10
6-3/4
4-1/2
7-1/2
2-3/4
4
4
5
3/8
1/2
5/8
3/4
5-7/8
10-7/8
3-1/8
4-3/8
4-1/4
5-1/4
Code
Ref.
7,
F28,
R10
7
5/8
3/4
1
1-1/8
5
8
9-1/2
Con
cre
te &
Mason
ry
1-800-328-5934 • www.USPconnectors.com26
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
CIA-EA – For use in anchoring threaded rod and rebar intonormal and lightweight concrete, stemwalls, concrete block, reinforced brick and unreinforced masonry. Bonds to mostconstruction materials. For use in substrate temperaturesabove 23˚ F.
Materials: 2-component, 100% solids, all weather, moisture insensitive, non-sag, non-shrink, solvent free, high strength epoxy acrylate.
Codes: ESR-1702, FL 4928
Installation:• Drill hole in concrete or masonry to specified depth and diameter.• Clean hole completely using compressed air and nylonbrush. Dust and debris left in the hole will reduce the holdingcapacity of the anchor.• Remove cartridge cap and insert cartridge into dispensingtool. Dispense a small amount of adhesive off to the side toequalize the cartridge.• Place mixing nozzle (and nut if required) onto cartridge and tighten. Dispense a small amount of adhesive off to the sideto ensure proper mixing. Do not use adhesive that is notmixed properly.• Inject adhesive into the bottom of the hole to avoidair pockets. Fill approximately one half to two thirds full.• Insert rod into hole while rotating one to two revolutions untilthe rod contacts the bottom of the hole.
Adhesive Anchoring Systems - CIA-EA
CIA-EA
5° - 10° 12 hrs 36 hrs
11° - 20° 9 hrs 30 hrs21° - 30° 6 hrs 24 hrs
31° - 40° 4 hrs 12 hrs41° - 50° 2 hrs 6 hrs
51° - 60° 15 min 70 min
61° - 70° 15 min 60 min71° - 80° 10 min 30 min
80° - 90° 4 min 25 min
CIA-EASubstrate
TemperatureF
Bolt UpTime
Full CureTime
3/8 7/16 3-3/8 6800 1700 5940 1485 2185 1125
1/2 9/16 4-1/2 11580 2895 10240 2560 3885 2000
5/8 11/16 5-5/8 23380 5845 17640 4410 6070 31253/4 13/16 6-3/4 28460 7115 25300 6325 8740 45007/8 15/16 7-7/8 28460 7115 25300 6325 11900 6130
1 1-1/8 9 44200 11050 40980 10245 15540 8000
1) Allowable load must be the lesser of bond or steel strength. 2) The tabulated values are for anchors installed at specified spacing (s) and edge (c) distances. Spacing and edge distances may be reduced, reference the Anchoring Systems Technical Guide for details. Linear interpolation may be used for intermediate spacing and edge distances. 3) The tabulated values are for anchors installed in concrete having the designated compressive strength or higher at the time of installation. 4) CIA anchors experience a reduction in tensile capacity with increased ambient temperatures. Temperature load factors must be applied when the anchors are installed in locations where the concrete temperatures may exceed 105°F. 5) The anchors cannot be used to resist pullout forces in overhead and wall installations, unless proper consideration is given to fire conditions. 6) Allowable load based on bond strength may be interpolated for compressive strengths between f'c = 2000 psi and f'c = 4000 psi. 7) Allowable loads may be increased by 33-1/3% for short term loading due to earthquakes or wind for Allowable Stress Design. 8) Bond strength values are based on a safety factor of 4.0.
CodeRef.
4, F24
f'c > 2500 psi
Allowable SteelCapacity for A307
(AISI 1018) rod
Shear Capacity basedon Concrete Strength (Lbs.)
CIA-EA
Tensile(Lbs.)
Shear(Lbs.)
Avg.Allow.
Avg.Ult.
Tensile Capacity basedon Concrete Strength (Lbs.)
RodDiameter
(in)
Drill BitDiameter
(in)
Embed. Depth
(in)
f'c > 2500 psi
Avg.Ult.
CIA-EA
Avg.Allow.
Cure TimesTension and Shear Capacities for Threaded RodInstalled in Normal Weight Concrete
10 oz.ACR-10
100% 133%
3/8 3-3/8 1-3/4 3160 790 10501/2 4-1/2 1-3/4 4160 1040 1385
5/8 4-1/2 1-3/4 4160 1040 1385
1) Shear load applied parallel to free edge.
Allowable ShearCapacity (Lbs.)1
Min. EdgeDistance
(in)
Avg. Ult.Capacity
(Lbs.)
RodDiameter
(in)
Embed. Depth
(in)
Shear Capacities for Threaded RodInstalled at a Close Edge Distancefor Sill Plates
For Applications withUSP Holdowns refer to
USP Anchor toConnector Guide
(USP1017) or visitwww.uspconnectors.com
Anchor to ConnectorGuide
USP2173-111
Con
cre
te &
Mason
ry
1-800-328-5934 • www.USPconnectors.com 27
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
CIA-GEL 7000 – For use in anchoring threaded rod and rebar into normal and lightweight concrete, stemwalls, concrete block, reinforced brick and unreinforced masonry (URM/UMB). Bonds to most construction materials. For use in substrate temperatures above 35˚ F.
Materials: 2-component, 100% solids, 1 to 1 ratio,moisture insensitive, non-sag, non-shrink, solvent free, high strength epoxy.
Codes: ESR-1702, FL 4928,L.A. City RR 25113 & RR 25029
Installation:• Drill hole in concrete or masonry to specified depth anddiameter.• Clean hole completely using compressed air and nylonbrush. Dust and debris left in the hole will reduce the holdingcapacity of the anchor.• Remove cartridge cap and insert cartridge into dispensing tool. Dispense a small amount of adhesive off tothe side to equalize the cartridge.• Place mixing nozzle (and nut if required) onto cartridge andtighten. Dispense a small amount of adhesive off to the side toensure proper mixing. Do not use adhesive that is not mixedproperly.• Inject adhesive into the bottom of the hole to avoid air pockets. Fill approximately one half to two thirds full.• Insert rod into hole while rotating one to two revolutions untilthe rod contacts the bottom of the hole.
Adhesive Anchoring Systems - CIA-GEL 7000
41° - 50° 12 hrs 72 hrs51° - 60° 8 hrs 48 hrs
61° - 70° 6 hrs 36 hrs
71° - 80° 4 hrs 24 hrs80° - 90° 4 hrs 24 hrs
SubstrateTemperature
F
CIA-GEL 7000
Bolt UpTime
Full CureTime
100% 133%
5 11120 2780 3705
12 13840 3460 4615
5 19040 4760 6346
12 23640 5910 7880
10 35400 8850 11800
15 41520 10380 138407/8 18 12
2-3/4
1-3/4
812-1/4
RodDiameter
(in)
Embed. Depth
(in)
Min. WallWidth(in)
7/8
5/8 9 5
Allowable TensileCapacity (Lbs.)
1-3/4
Min. EdgeDistance
(in)
Min. EndDistance
(in)
Avg. Ult.Capacity
(Lbs.)
100% 133%
1/2 4-1/2 1-3/4 5792 1448 1926
5/8 5-3/4 1-3/4 10800 2700 3600
1) Shear load applied parallel to free edge.
Allowable ShearCapacity (Lbs.)1
Min. EdgeDistance
(in)
Avg. Ult.Capacity
(Lbs.)
RodDiameter
(in)
Embed. Depth
(in)
1-7/8 4760 1190 -- -- -- --
3-3/8 8600 2150 5880 14702-1/2 7760 1940 -- -- -- --
4-1/2 13980 3495 14220 3555
3-1/8 10400 2600 -- -- -- --5-5/8 21600 5400 19060 4765
3-3/4 15660 3915 -- -- -- --6-3/4 26740 6685 27620 6905
7/8 1 7-7/8 33968 8492 34748 8687 11900 61301 1-1/4 9 49320 12330 44720 11180 15540 8000
1) Allowable load must be the lesser of bond or steel strength. 2) The tabulated values are for anchors installed at specified spacing (s) and edge (c) distances. Spacing and edge distances may be reduced, reference the Anchoring Systems Technical Guide and/or ICC-ES ESR-1702 for details. Linear interpolation may be used for intermediate spacing and edge distances. 3) The tabulated values are for anchors installed in concrete having the designated compressive strength or higher at the time of installation. 4) CIA anchors experience a reduction in tensile capacity with increased ambient temperatures. Temperature load factors must be applied when the anchors are installed in locations where the concrete temperatures may exceed 105°F. 5) The anchors cannot be used to resist pullout forces in overhead and wall installations, unless proper consideration is given to fire conditions. Reference ICC-ES ESR-1702 for more information. 6) Allowable load based on bond strength may be interpolated for compressive strengths between f'c = 2000 psi and f'c = 4000 psi. 7) Allowable loads may be increased by 33-1/3% for short term loading due to earthquakes or wind for Allowable Stress Design. 8) Bond strength values are based on a safety factor of 4.0.
CodeRef.
4, F24,R2, R4
1125
2000
3125
4500
2185
3885
Avg.Allow.
Avg.Ult.
Avg.Allow.
1/2 5/8
3/8 1/2
5/8 3/4 6070
3/4 7/8 8740
Allowable SteelCapacity for A307
(AISI 1018) rod
Shear Capacity basedon Concrete Strength (Lbs.)
f'c > 2500 psi
Avg.Ult.
CIA-GEL 7000
Tensile(Lbs.)
Shear(Lbs.)
Tensile Capacity basedon Concrete Strength (Lbs.)
RodDiameter
(in)
Drill BitDiameter
(in)
Embed. Depth
(in)
f'c > 2500 psi
CIA-GEL 7000
Cure Times
Shear Capacities for Threaded RodInstalled at a Close Edge Distance for Sill Plates
Tension Capacities for Threaded Rod Installed in Concrete Stemwall Foundations
Tension and Shear Capacities for Threaded Rod Installed in Normal Weight Concrete
CIA-GEL 7000
10 oz.GEL-10
22 oz.GEL-22
Con
cre
te &
Mason
ry
1-800-328-5934 • www.USPconnectors.com28
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
L
E
HEmbedment
line
Identification stamp &
alignment indicator
STB/STBL
ESlab
Embedmentline
4˝ Min.
Footing
Typical doublepour installation
Embossed ends provide guides for embedment angle and depth. An embedment line is embossed on the shaft for easy installation. Featuresrolled threads for high tensile strength.
STB – For monolithic slabs and double pour concrete installations.
STBL – Designed for use with 3x sill plates. Excellent choice for use withtaller holdown washers like those in the PHD series.
Materials: ASTM A 36 steel, also conforms to ASTM F 1554 and ASTM A 307 requirements for bolts
Finish: NoneOptions: STB34 and STBL24 are available in Hot-dip
galvanized. To order, add HDG to the end of the stock number, as in STB34-HDG.
Codes: ER-5321
Installation:• Select appropriate STB or STBL Anchor Bolt.• Use concrete with minimum compressive strength of 2,500 psi at 28 days.• Minimum center-to-center spacing between bolts is 2(E) for anchors acting simultaneously in tension.• Match embedment depth with embedment line on the STB or STBL shaft.• The STB or STBL does not need to be tied to the rebar.• Nuts and washers are not included.
Typical STB/STBL monopour installation
Threaded Rods – THR series
Materials: A36 SteelFinish: Hot-dip galvanizing
Ref. No. L THR125-HDG RFB#4X5HDG 1/2 5
THR126-HDG RFB#4X6HDG 1/2 6
THR128-HDG RFB#4X8HDG 1/2 8 THR5816-HDG RFB#5X16HDG 5/8 16
USPStock No.
BoltDia.
CodeRef.
120
THR Typical THR installation
Anchor Bolts – STB & STBL series
E
1 3/4˝ Min.edge distance
5˝ Min.end distance
6˝ Min. for 5/8˝ STB/STBL
8˝ Min. for 7/8˝ STB/STBL
continued on next page
USP2173-111
Con
cre
te &
Mason
ry
1-800-328-5934 • www.USPconnectors.com 29
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
5˝ from end 24˝ from end 5˝ from end 11˝ or > from end
Ref. No. L H Wind / Seismic Wind / Seismic Wind / Seismic Wind / Seismic
STB16 SSTB16 5/8 17-13/16 5 12-13/16 5215 5215 1850 4315
STB20 SSTB20 5/8 21-13/16 5 16-13/16 5215 5215 1850 4315
STB24 SSTB24 5/8 25-13/16 5 20-13/16 5215 5215 1850 4315 STB28 SSTB28 7/8 31 5 26 9335 10425 -- -- -- --
STB34 SSTB34 7/8 36 6 30 9335 10425 -- -- -- -- STB36 SSTB36 7/8 38 8 30 9335 10425 -- -- -- --
STBL16 SSTB16L 5/8 19-9/16 6-3/4 12-13/16 5215 5215 1850 4315
STBL20 SSTB20L 5/8 23-9/16 6-3/4 16-13/16 5215 5215 1850 4315 STBL24 SSTB24L 5/8 27-9/16 6-3/4 20-13/16 5215 5215 1850 4315
STBL28 SSTB28L 7/8 32-3/4 6-3/4 26 9335 10425 -- -- -- --
1) Design loads are based on the average ultimate, from a series of five tests, with a safety factor of three. 2) Loads may not be increased for short term loading. 3) Minimum center to center spacing between bolts is 2(E) for anchors acting in tension. 4) Minimum edge distance is 1-3/4˝. 5) Concrete stemwall shall be a minimum of 6˝ thick for 5/8˝ anchor bolts and 8˝ for 7/8˝ anchor bolts. 6) End distance shall be no less than 5˝. 7) Connection is limited by lowest of bolt or holdown capacity. 8) Concrete block shall be minimum 10˝ block.
Dimensions Allowable Tension Load1,2,3
Concrete5 Concrete Block8
CodeRef.
L4
USPStock No.
BoltDia.
Min.Embed.
(E)
Minimum End Distance6 Minimum End Distance6
30˝ M
in. rebar length
5˝ Min.
13/4˝ Min.
12˝ Min.
Place diagonal in corner position
1-800-328-5934 • www.USPconnectors.com
Typical STB/STBLconcrete block installation
Min. rebar length
2x E + 12˝ Min.
5˝ Min.
1 3/4˝ Min.
Plan View of Continuous stem wall installation
Plan View ofCorner installation
Min. rebar length
2x E + 12˝ Min.
Place at 45˚diagonally
from wall
Plan View ofEnd wall installation
1-800-328-5934 • www.USPconnectors.com
Plan view of STB/STBLplacement in concrete stemwall
0˚
CornerInstallation
Non-CornerInstallation
CornerInstallation
Outside edgeof concrete
Anchor Bolts – STB & STBL series continued
1-800-328-5934 • www.USPconnectors.com
PHD2A
TDX2-TZ LTS20B
HTT16
PHD4A
TD5
PHD8
UPHD8 TD7
TD9
TD12
* Recommend installation of washer under nut of anchor bolt.1) STBL model are recommended for use with PHD/PHDA and UPHD8 holdowns on (2) 2x and 3x sill plates.
2x, 3x, (2) 2x Sill Plates1
STB28STBL28
STB34
STB16STBL16
STB20STBL20
MonoPour
DoublePour
STB20STBL20
STB24STBL24
HTT22STB24
STBL24STB24
STBL24
USPStock No.
Anchor Bolt Selection table
Monolithic or Double Pour Foundations – Prior topour, install the STB or STBL in an upright positionand at a 45° angle to the wall. Install one horizontal #4 rebar at a depth of 4˝ (minimum). (See illustrations.)
Concrete Block Applications – Prior to cell pour,install the STB or STBL in an upright position and at a 45° angle to the wall. (See illustrations.) Use theembossed angle guide on the end of the STB orSTBL shaft as a guide. Install one horizontal #4rebar at a depth of 4˝ and one vertical #4 rebar maximum 48˝ o.c. spacing. Fill all cells with concretehaving a minimum 2,000 psi compressive strength.
Con
cre
te &
Mason
ry
1-800-328-5934 • www.USPconnectors.com30
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Anchor Bolts – AB series
FT – Connect 1x and 2x nominal form lumber in low foundation walls up to 4 feet high.
WG – V-shaped wedge assures rigidity and consistent form spacing.
Materials: FT – 18 gauge, WG – 14 gaugeFinish: G90 galvanizing
Installation:• Use the Spacing Guide char t to determinespacing between FT units. Each level in chart assumes12˝ form boards. Wall thickness from 6˝ to 12˝.• Install with “V” facing up.• Use (2) WG wedges for each tie. Insert wedge intoinside slots for 1x nominal forms and outside slots for2x nominal forms.• No walers or stiff-backs are used.• Vertical ties to keep forms from separating are notincluded.• Form deflection may be substantial. Check deflection,if it is critical, and move ties to compensate.• Forming lumber is assumed to have fb of 1,000 psi.• Not recommended for pours greater than 4 feet inheight.
Wedge
Ref. No. W L Qty
FT6 WT6 18 5/8 10-5/8 2 6 FT8 WT8 18 5/8 12-5/8 2 8
FT10 WT10 18 5/8 14-5/8 2 10 FT12 WT12 18 5/8 16-5/8 2 12
WG W1 14 11/16 3-5/8 -- -- -- -- 120
1) May be used with either 3/4˝ or 1-1/2˝ forming materials. 2) Breaking strength is approximately 775 pounds. Space as necessary to prevent form blow-out.
USPStock No.
SteelGauge
FootingWidth
or WallThickness
Dimensions
CodeRef.
120
1x 2x 1x 2x 1x 2x 1x 2x
12˝ or Less 2' 6˝ 4' 0˝ -- -- -- -- -- -- -- -- -- -- -- --
12˝ - 24˝ 1' 6˝ 3' 0˝ 2' 6˝ 4' 0˝ -- -- -- -- -- -- -- --
24˝ - 36˝ 1' 0˝ 2' 0˝ 1' 6˝ 3' 0˝ 2' 6˝ 4' 0˝ -- -- -- --
36˝ - 48˝ 0' 9˝ 1' 6˝ 1' 0˝ 2' 0˝ 1' 6˝ 3' 0˝ 2' 6˝ 4' 0˝
1) Factor of safety against tensile failure of tie is 1.5 or more.
ConcreteLift Height
Level 1 Level 2 Level 3 Level 4
3 5/8˝
11/16˝
3/16˝WG Wedgemust orderseparately
Typical FT/WGinstallation
Spacing Guide chart
L
W
FT
Concrete Form Ties & Wedge – FT series & WG
Materials: Bolt: ASTM F 1554, Nut: ASTM A 563, Washers: ASTM F 844
Finish: Hot-dip galvanized
Installation:• Select appropriate AB Anchor Bolt.• Use concrete with minimum compressivestrength of 2,000 psi at 28 days.• Nuts and washers are included.• Anchor bolts intended for use to satisfy codeprescribed anchoring of mudsill plates, and shallbe installed as defined in the code.• Allowable loads shall be derived in accordancewith the code.
Ref. No. L AB126-HDG LBOLT50600HDG 1/2 6
AB128-HDG LBOLT50800HDG 1/2 8 AB1212-HDG LBOLT50120HDG 1/2 12
AB5812-HDG LBOLT62120HDG 5/8 12
are designated in bold font.
New products or updated product information
USPStock No.
BoltDia.
CodeRef.
100
L
AB128-HDG
The codes specify a minimum diameter andembedment into masonry or concrete foranchor bolts used in foundation plates or sills.IRC R403.1.6, IBC 2308.6, 2308.12.9.
Typical AB128-HDGinstallation
NEWSIZE
USP2173-111
Con
cre
te &
Mason
ry
1-800-328-5934 • www.USPconnectors.com 31
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
F1Uplift
F2
F3
4˝ min.embed
Typical FA3 installation to mudsill and stud
FA3 Form board installation
1 1/2˝
4 5/8˝
5 3/4˝
1˝
Embossed linesprovide guide for matching to edgeof form board
FA3
Alternate FA3 installation
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
For installation into concrete slabs. The FA3 features a split flange for nailing to both mudsill and stud for greater framing versatility.
Materials: 16 gaugeFinish: G90 galvanizing
Options: FA3 is available in Triple Zinc.To order, add TZ to end of stock number,as in FA3-TZ.
Codes: ESR-2787
Installation:• Use all specified fasteners. See Product Notes, page 15.• Use a minimum of two anchors per mudsill. An anchor should always be within 12˝ of the end of each mudsill section. Follow spacing guidelines in chart.• Do not rely on these anchors to secure concrete sections together betweencold joints.• Insert into wet concrete (minimum strength of 2,000 psi). Place mudsill afterconcrete cures. Secure flanges to sill (and stud, if applicable), bending flangesas needed to achieve a tight fit. Fasten as directed in chart.
Foundation Anchors – FA3 series
Min
Stemwall
Side Top Thickness Uplift F1 F2 Uplift F1 F2
Ref. No. Qty Qty Type Qty Type W L IE D (in.) Concrete10 160% 160% 160% 160% 160% 160%
Uncracked 1010 625 735 0.066 1010 625 735 0.066
Cracked 985 545 735 0.064 845 470 645 0.055Uncracked 755 615 465 0.015 755 615 465 0.015
Cracked 755 545 465 0.015 755 470 465 0.015
1) A 10d x 1-1/2" nail has a diameter of 0.148 inch and length of 1-1/2 inches. 2) Predrilled holes are not required 3) Allowable Stress Design (ASD) values have been adjusted for a load duration factor, CD, of 1.6 corresponding to a ten-minute load duration (i.e. wind or earthquake loading) in accordance with the NDS. The ASD loads do not apply to loads of other durations. 4) FA3 capacities are based on using a single-ply 2x sill plate. 5) Minimum distance of 1.5 x IE ( 6 inches) is required to obtain the listed capacity. 6) Minimum anchor spacing for full capacity is 2 x lE. For spacing less than that reduce capacity proportionally. 7) The allowable loads are based on lumber with a specific gravity of 0.50 and a moisture content of 19% or less. 8) Uplift deformation based on wood connection strength. 9) Minimum concrete strength f'c = 2500 psi
New products or updated product information are designated in bold font.
2 x4 or 2 x 6
MAS, MASA, MASP
CodeRef.
13 FA3 Mudsill & Stud
-- -- 6
PlateSize
2 2
FA3 Mudsill Only
-- --2 10d x 11/2"4
10d x 11/2"2 10d x 11/2"
Sill Plate Stud
DF / SP Allowable Loads (Lbs)3,4,6,7,8
USPStock No
ASD
(in) 8
Wind and SDC A & B SDC C-F
ASD
(in) 8
Fastener Schedule1,2 Dimensions (in.)
SteelGa.
616
45/8 4 1
45/8 4 111/2
11/2
Typical FA3 installationin concrete
Con
cre
te &
Mason
ry
1-800-328-5934 • www.USPconnectors.com32
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Foundation Anchors – ST series
1-800-328-5934 • www.USPconnectors.com
AlternateST2-TZ
installation with3/4˝ center hole
in mudsill
Uplift
F1
F2
AlternateST1-TZ
installation with3/4˝center hole
ST1-TZ – For installation into concrete slab or poured stemwalls. The ST1-TZ features a prebent base flange to assure proper anchoring into concrete. For concrete/masonry installations, refer to theFA & ST Foundation Anchors Technical Bulletin.
ST2-TZ – For installation into concrete slab, poured stemwalls or concrete/masonry. The ST2-TZ features a prebent base flange to assure proper anchoring into concrete. Do not use in red clay brick.
Materials: 18 gaugeFinish: G90 galvanizingCodes: NER 530
Installation:• Use all specified fasteners. See Product Notes, page 15.• Use a minimum of two anchors per mudsill. An anchor should always be within 12˝ of the end of each mudsill section. Follow spacing guidelines in chart.• Do not rely on these anchors to secure concrete sections together betweencold joints.• Spread sill flanges to mudsill width prior to insertion into wet concrete (minimum strength of 2,000 psi). Alternate installation is possible by inserting unbent flanges through 3/4˝ center hole predrilled inmudsill. Foundation anchors may also be attached to mudsill and then inserted into wet concrete. When installing ST2-TZ into concrete block, fill cellswith grout with a minimum strength of 2,000 psi. Concrete block edges mayneed to be beveled to facilitate installation.• For additional installation details and information on mudsill anchors refer toST Foundation Anchors Technical Bulletin.• ST2-TZ in masonry construction shall be installed in the core of the block andgrouted with concrete grout designed for that purpose. In no case, shall they beinstalled in a mortar joint.
DO NOT installST1-TZ and ST2-TZwithout pre-bending
sill flanges in “Y”configuration
Min. embed8 1/2˝ E
TypicalST1-TZ
installationin concrete
ST1-TZ
10˝18˝
ST2-TZ
Spread sill flanges to sillwidth prior to insertion
into wet concrete
F1 F2 F3 Uplift
Ref. No. Qty Type Qty Type 160% 160% 160% 160%
ST1-TZ MAB15Z 18 4 8d x 1-1/2 4 8d x 1-1/2 8-1/2˝ *5-1/2 565 745 745 825
ST2-TZ MAB23Z 18 4 8d x 1-1/2 4 8d x 1-1/2 16-1/2˝ *5-1/2 565 745 745 825
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) 8d x 1-1/2 nails are 11 gauge (0.131˝ diameter) by 1-1/2˝ long. 3) Anchor spacing and design loads assume treated Douglas Fir-Larch with Fc perpendicular @ 625 psi; replaces code prescribed 1/2˝ anchor bolt with standard washer, spaced 6 ft. on center. 4) If installed in the alternate configuration, the ST1-TZ shall be embedded 11˝ and ST2-TZ 16˝. *When a 2 x 8 mudsill is used for ST1-TZ or ST2-TZ, maximum spacing is 3 feet unless alternate installation is used.
Allowable Loads (Lbs.)1
Min.
Embed.4
(E)
Max.
Spacing3
(Feet)PlateSize
Fastener Schedule2
USPStock No.
2 x 4 - 6
SteelGauge
MudsillTop
MudsillSide
L6
CodeRef.
DF-L / SP
USP2173-111
Con
cre
te &
Mason
ry
1-800-328-5934 • www.USPconnectors.com 33
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Bearing Plate
1/2˝ Min. clearance
Concrete pilaster
Rebar welded tobearing plate
Uplift
F2
Typical KGLB installation
W1 1/2˝
2 1/2˝2 1/2˝
1 1/4˝
3˝
3˝
T
D
L
KHGLB
KGLB – Single bolt, bearing only.
KGLBT – Double bolt with Structural Tee provides uplift and horizontal resistance.
KHGLB – Double bolt design provides uplift and horizontal resistance.
Materials: Flanges – 1/4˝ steelBearing Plate – See chartAnchor dowels – 3⁄4˝ x 12˝ rebar
Finish: USP primerOptions: Consult USP for non-catalog variations.
Codes: ER-2725
Installation:• Use all specified fasteners. See Product Notes,page 15.• Bolt holes shall be a minimum of 1⁄ 32˝ to amaximum of 1⁄16˝ larger than the bolt diameter.• Concrete or masonry walls must be checkedby a design professional for adequacy to resistlateral or uplift loads transferred from the beamseat anchor.
Ref. No. W L T D Qty Dia. Concrete3
KGLB5A GLB5A 5-1/4 7 1/4 5 1 5/8 11790 11790
KGLB5B GLB5B 5-1/4 7 3/8 6 1 5/8 14145 14145
KGLB5C GLB5C 5-1/4 7 3/8 7 1 5/8 16505 16505 KGLB5D GLB5D 5-1/4 7 3/8 8 1 5/8 18860 18860
KGLB7A GLB7A 6-7/8 9 1/4 5 1 3/4 15525 15525 KGLB7B GLB7B 6-7/8 9 3/8 6 1 3/4 18630 18630
KGLB7C GLB7C 6-7/8 9 3/8 7 1 3/4 21735 21735
KGLB7D GLB7D 6-7/8 9 3/8 8 1 3/4 24840 24840
1) Beams must fully bear on plates. 2) The loads are based on the bearing value listed times the bearing area equal to W x D. (Note that full bearing plate area is not used.) Bearing loads shall be reduced where limited by wood bearing on the plate. 3) The loads on concrete are based on allowable wood bearing stress perpendicular to the grain of 460 psi and actual beam width times beam bearing length. 4) Designer shall specify minimum edge and spacing requirements in masonry or concrete structure. 5) Concrete or masonry support structure is assumed adequate to support loads listed.
L3
Dimensions Allowable Bearing Loads (Lbs.)1,4,5
USPStock No.
Masonry
@ 375 psi2
Bolt Schedule
CodeRef.
F23,4 Uplift 1603
Ref. No. D L T Qty Dia. 5-1/8 6-3/4 8-3/4 10-3/4 160%
KHGLBA HGLBA 3-1/4 to 9 5 10 3/8 2 3/4 18750 11790 15525 20125 -- -- 9870 3905
KHGLBB HGLBB 3-1/4 to 9 6 10 3/8 2 3/4 22500 14145 18630 24150 -- -- 9870 3905 KHGLBC HGLBC 3-1/4 to 9 7 10 3/8 2 3/4 26250 16505 21735 28175 -- -- 9870 3905
KHGLBD HGLBD 3-1/4 to 9 8 10 3/8 2 3/4 30000 18860 24840 32200 -- -- 9870 3905
KGLBT512 GLBT512 3-1/4 to 11 5-1/4 12 5/16 2 3/4 24750 12965 17080 22140 27200 9870 3905 KGLBT612 GLBT612 3-1/4 to 11 6-1/2 12 3/8 2 3/4 29250 15325 20185 26165 32145 9870 3905
KGLBT516 GLBT516 3-1/4 to 15 5-1/4 16 5/16 2 3/4 27200 12965 17080 22140 27200 9870 3905 KGLBT616 GLBT616 3-1/4 to 15 6-1/2 16 3/8 2 3/4 32145 15325 20185 26165 32145 9870 3905
KGLBT520 GLBT520 3-1/4 to 19 5-1/4 20 5/16 2 3/4 27200 12965 17080 22140 27200 9870 3905
KGLBT620 GLBT620 3-1/4 to 19 6-1/2 20 3/8 2 3/4 32145 15325 20185 26165 32145 9870 3905
1) Beams must fully bear on plates. 2) The loads on concrete are based on allowable wood bearing stress perpendicular to the grain of 460 psi and actual beam width times beam bearing length. 3) Allowable loads have been increased 60% for wind or seismic loads and are based on bolt in wood values only. Loads assume concrete or masonry structure is adequate to resist loads in those directions. 4) Loads must be be reduced if the allowable lateral load (F2) for masonry or concrete column governs. 5) Designer shall specify minimum edge and spacing requirements in masonry or concrete structure.
CodeRef.
L3
Allowable Bearing Loads (Lbs.)1,5
On Concrete with Beam Width
2
Masonry@ 375 psi
Min. 3-1/8Beam
Width (W)
Bolt Schedule
USPStock No.
RangeW
Dimensions
12˝
LD
T
3 1/2˝
W
3˝
KGLB
KGLBT
3 1/2˝
1 1/4˝1 1/2˝
D
L
3˝
3˝
T
4˝ 12˝
Structuraltee
W
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Laminated Beam Seats – KGLB, KGLBT, & KHGLB series
Con
cre
te &
Mason
ry
1-800-328-5934 • www.USPconnectors.com34
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
W
S
L
H
D
1˝
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Floor Girder Hangers- KGH Series
1-800-328-5934 • www.USPconnectors.com
Connects girder beams to foundation walls and eliminates the need to block outpockets or inserts while forming foundation.
Materials: 12 gaugeFinish: USP primer
Options: Consult USP for non-catalog design variations.Codes: ESR-1280, FL11664, LA City RR 25749
Installation:• Use all specified fasteners. See Product Notes, page 15.• H dimension assumes 2x mudsill. For 3x or larger mudsill, pleasecontact factory.• The 11⁄2˝ hole, centered in the saddle, allows for installation over any protrudingfoundation bolts. This is not required. • Placement of a wood sill over the top of the KGH top flange is required toachieve allowable loads.
Dimensions Allowable Loads (Lbs.)
DF-L / SP
Ref. No. W L D S H Qty Type 100% 125%
4 x 6 KGH46-6 GH46-6 12 3-9/16 5 3-1/4 6 4 4 16d 2050 2050 4 x 6 KGH46-8 GH46-8 12 3-9/16 5 3-1/4 8 4 4 16d 2050 2050
4 x 8 KGH48-6 GH48-6 12 3-9/16 5 3-1/4 6 6 4 16d 2050 2050 4 x 8 KGH48-8 GH48-8 12 3-9/16 5 3-1/4 8 6 4 16d 2050 2050
6 x 6 KGH66-6 GH66-6 12 5-1/2 6-1/4 3-1/4 6 4 4 16d 2035 2035
6 x 6 KGH66-8 GH66-8 12 5-1/2 6-1/4 3-1/4 8 4 4 16d 2035 2035 6 x 8 KGH68-6 GH68-6 12 5-1/2 6-1/4 3-1/4 6 6 4 16d 2035 2035
6 x 8 KGH68-8 GH68-8 12 5-1/2 6-1/4 3-1/4 8 6 4 16d 2035 2035
1) Minimum header thickness shall be 1-5/8˝ for 16d nails.
CodeRef.
2, F20, R12
Fastener
Schedule1GirderSize
USPStock No.
SteelGauge
Typical KGH installation
KGH
Option Skewed1,2 Saddle
Range 1˚ to 45˚ -- --
1) Skewed hangers with skews greater than 15° may have all joist nailing on outside flange. 2) Skewed hangers with skews greater than 15° require the joist end to be bevel cut.
AllowableLoads
Ordering
100% of table load.100% of table load
per side.
Add SA, and saddlewidth required
to product number.Ex. KGH46-6SA=5-1/2˝
Add SK, angle required,and right (R) or left (L),
to product number.Ex. KGH46-6SK45R
Specialty Options Chart – refer to Specialty Options pages 194, 196 to 197 for additional details.
Retro Plate – RP6
Uses heavy gauge HRPO steel and a large surfacearea to distribute seismic forces on masonry exteriors.
Materials: 3/8˝ plateFinish: USP primer
Installation:• Install with a 3/4˝ diameter steel threaded rod.
Ref. No.
RP6 RP6 120
USPStock No.
CodeRef.
3˝
3˝
6˝
6˝
RP6
3/4˝ dia.threaded rod
Typical RP6 installation
USP2173-111
Hold
ow
ns
1-800-328-5934 • www.USPconnectors.com 35
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Predeflected Holdowns . . . . . . . . Page 36• PHD & PHDA SeriesInnovative design increases holdown stiffness. Connects to wood postwith WS series wood screws.
Tension Ties. . . . . . . . . . . . . . . . . . . Pages 37• HTT SeriesHeavy tension tie. Bolts to foundation and nails to post.
• LTS Series & LTTI31Light-capacity tension tie. Bolts to foundation and nails to post.
Holdowns . . . . . . . . . . . . . . . . . Pages 38-40• TD & TDX SeriesStandard holdown. Connects to post with bolts.
• UPHD SeriesHigh capacity holdown. Connects to post with wood screws.
Foundation Straps . . . . . . . . . Pages 41-45• HPAHD & PAHD42Embedded strap holdowns for solid end posts.
• LSTAD & STAD SeriesEmbedded strap holdowns for built-up 2x end posts.
• TA SeriesStraps through masonry foundation wall
Purlin Anchors. . . . . . . . . . . . Pages 45-46• HPA, PA, PAI SeriesEmbedded strap for concrete to purlin connections.
Concrete Angles. . . . . . . . . . . . . . . Page 47 • TDL SeriesLight-capacity foundation strap. Bolts to foundation and nails or boltsto post.
Cold Formed Steel Holdowns . . . Page 47 • LTS20BLight capacity tension tie strap• HTT14SMedium capacity tension tie.• TDS SeriesHeavy capacity tension tie.
PHDA PHD
HTT
HPAHD PAHD42
TDL
HPA/PA PAI
LSTAD/STAD TA
LTS LTTI31
TDX UPHD
TDSHTT14SLTS20B
TD
1-800-328-5934 • www.USPconnectors.com
Holdowns
Hold
ow
ns
1-800-328-5934 • www.USPconnectors.com36
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Predeflected Holdowns – PHD & PHDA series
1-800-328-5934 • www.USPconnectors.com
Reduces eccentricity in the studs/post decreased centerlinedimension. No thru-bolts to countersink.
Materials: See chart.Finish: G90 galvanizingCodes: ER-0200
Installation:• Use all specified fasteners. See Product Notes, page 11.• Place the PHD/PHDA over the anchor bolt. No washer isrequired.• Install with USP’s code evaluated WS3 (1/4˝ x 3˝) WoodScrews, which are provided with the holdown.• Tighten anchor bolt nuts finger tight snug to base, plus 1/3to 1/2 additional turns with a wrench. To prevent loosening ofthe anchor nut during critical loading, use a locking nut ortighten a second nut over the first to lock nuts in place.• PHD/PHDA Predeflected Holdowns may be installed offsill plate with no load reduction.• The design engineer may specify any alternate anchoragecalculated to resist the tension load for a specific application.Anchorage exposure length should take the bearing plateheight of 15/8˝ into account, anchor bolt thread should visiblyextend above nut.• If used to anchor a built-up post, such as a double 2 x 4, thepost component shall be designed to act as a single unit.Holdown fasteners specified shall not be considered to attachmultiple plys together.• For anchorage options see STBL Anchor Bolt section onpages 28-29.
W
H
CL
D
1 5/8˝
Typical PHD5Ainstallation
PHD5APHD8
DF-L / SP S-P-F
Ref. No. W H D CL Qty Dia. Qty 160% 160%
PHD2A HDU2-SDS2.5 14 3 7-3/4 2-5/8 1-3/8 1 5/8 6 3215 2700 0.155
PHD4A HDU4-SDS2.5 14 3 9-3/4 2-5/8 1-3/8 1 5/8 10 5215 4380 0.137
PHD5A HDU5-SDS2.5 14 3 11-11/16 2-5/8 1-3/8 1 5/8 14 6525 5480 0.135
PHD8 HDU8-SDS2.5 12 3-1/4 16-1/2 3 1-3/8 1 7/8 24 8185 6875 0.062
1) Allowable loads have been increased 60% for wind and seismic loads; no further increase shall be permitted. 2) The designer must specify anchor bolt type, length, and embedment. 3) Deflections are derived from static, monotonic load tests of devices connected to DF-L wood members with specified fasteners. 4) The designer shall consider the effect of compression, bearing, tension, and combined bending due to device eccentricity when applicable. 5) The PHD/PHDA may be elevated off the sill. 6) WS3 wood screws are 1/4 ˝ x 3˝ and are included with PHD/PHDA models. 7) Minimum post thickness is 3˝. Consult USP for installations less than 3˝. New products or updated product information are designated in bold font.
20
USPStock No.
SteelGauge
Dimensions Fastener Schedule Allowable Tension Loads (Lbs.)1,4,7
Anchor
Bolts2
WS3 Wood
Screws6CodeRef.
Deflection atAllowable Load
∆ (in) at 160%3,5
NEW &
IMPROVED
PHDADESIGN
L
D
CL
W
USP2173-111
Hold
ow
ns
1-800-328-5934 • www.USPconnectors.com 37
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
HTT series – Secures multi-ply studs or posts to mudsills or foundation. Nail fastening makes for a convenient connection to studs or posts in cramped retrofit installations.
LTS series – The LTS19 is designed for nail-on installation to 2x joists or studs, andthe LTS20B provides a nail or bolt fastening option. The LTS20B will accommodate wood I-Joists if 10d x 11⁄ 2˝ nails are used instead of the specified 16d nails.
LTTI31 – An open web joist tension tie designed for use with masonry or concrete construction.
Materials: See chart Finish: G90 galvanizingCodes: ER-0200, NER 608
Installation:• Use all specified fasteners. See Product Notes, page 11.• Use all specified fasteners to attach the strap portion of the connector to the side of stud, post, joist,purlin, or beam. Secure the base to the concrete or masonry wall with specified anchor bolt. A designprofessional shall specify the type, length, and embedment of the anchor bolt. No washers required.• LTTI31 and LTS connectors must be mounted flush to the surface of the mudsill.• Allowable loads are based on either nail or bolt fastening; nail and bolt values cannot be combined.• Washers are not required on transfer plates that fit over the anchor bolt.• Tighten anchor bolt nuts finger tight snug to base plus, 1/3 to 1/2 additional turns with a wrench. Toprevent loosening of the anchor nut during critical loading, use a locking nut or tighten a second nutover the first to lock nuts in place.
Hanger not shown
Typical LTTI31installation
L
CL
W
D
3/8˝ Typ.
11/16˝
6 3/16˝
2 3/8˝
6˝
LTTI31
LTS19
CL D
L
2 1/2˝
W
1/4˝ transferplate
CLD
L3 3/4˝
6 1/4˝
W
1/4˝ transfer
plate
LTS20BHTT4HTT5 similar
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Tension Ties – HTT series, LTS series & LTTI31
HTT16HTT22 similar
CL
L
D
W
1 3/4˝
See STB anchor bolt
pages 28-29
Typical HTT22installation
Ref. No. Strap Plate W L D CL Qty Dia. Qty Type 160% ∆ (in)5,6
10d x 1-1/2 2715 0.09510d 3295 0.098
16d x 2-1/2 4465 0.14310d x 1-1/2 3225 0.088
10d 4745 0.12216d x 2-1/2 5430 0.141
18 10d 3250 0.12518 16d 4290 0.09932 10d32 16d
LTTI31 LTTI31 18 3 3-3/4 31 2-5/8 1-3/8 3 1 5/8 18 10d x 1-1/2 2805 0.175 LTS19 LTT19 16 3 1-3/4 22-1/4 3 1-1/2 2-1/2 1 3/4 8 10d 1205 0.132
10 10d x 1-1/2 1100 0.12810 16d 1105 0.1282 1/2 1175 0.128
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) Minimum nail embedment shall be 1-1/2˝ for 10d nails and 1-5/8˝ for 16d nails. Bolts require a minumum length of 1-1/2˝ in vertical member for the listed loads. 3) 16d sinkers may be substituted for the specified 10d common nails with no load reduction. 4) The designer must specify anchor bolt type, length and embedment depth. 5) Deflections are derived from static, monotonic load tests of devices connected to DF-L wood members with specified fasteners. 6) HTT holdowns raised off of the sill plate may have higher deflection values. 7) LTTI and LTS holdowns shall be installed tight to the sill plate.
1-3/8 1-3/4 1 5/8
1-3/4 1 5/8
HTT22 -- -- 10 -- -- 2-1/2 21-1/2 2
2-1/2 15-5/8 2 1-3/8 HTT16 -- -- 10 -- --
-- --
-- -- 2-3/4
2-3/4
3
3 13-15/16
10-7/16
3
USP
Stock No.7
12 HTT4 HTT4
HTT5 HTT5
LTS20B LTT20B
12 1
1-3/4
1-3/4
1-3/8
CodeRef.
5/8
5/8
Steel Gauge Dimensions Fastener Schedule
NailSpacing
AnchorBolts4
Strap2,3
1-3/8
Allowable Tension
Loads (Lbs.)1
12 3 2 20
DF-L / SP
1-1/2 3-3/4 1
1 18
28
3/4
5370 0.125
20
L8
20
Typical LTSInstallation
NEW
Hold
ow
ns
1-800-328-5934 • www.USPconnectors.com38
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Moisture barriermay be required
Typical TDX2-TZinstallation
End distance
Wall stud
Threadedrod
Use bearing platesbetween nut
and studBP’s required by theCity of Los Angeles.
Check with your localbuilding code. (NDS
section 11.1.2.3 requires a metal
plate, metal strap,or min. of a std.
cut washer.
TD – Different welded configurations and sizes acheive a great deal of versality within the TD series.TDX – The TDX2 and TDX5 feature formed designs, all others are welded. All are self-jigging.All models, except TD2, TD5, and TD7, feature a self-jigging design with code requiredend distances built in. (End distance = 7 bolt diameters from the top of the sill to the center of the first bolt hole in the studs or post.)
Materials: See chartFinish: TDX2-TZ – G-185 galvanizing;
All others – USP primerCodes: ER-0200
Patents: #5,092,097 — TDX2
Installation:• Use all specified fasteners. See Product Notes, page 11.• Do not use lag bolts. Washers are not required for anchor bolts or between holdown and bolthex head, but standard washers should be used against stud or post under the nut. See page17 for BP/LBP Bearing Plates.• Bolt holes should be a minimum of 1⁄32˝ to a maximum of 1⁄16˝ larger than the bolt diameter(per 2005 NDS®, Section 11.1.2).• See pages 28-29 for STB Anchor Bolt section for anchorage options. A design professional may specify alternate anchorage with conventional anchor bolts.• A design professional shall determine the adequacy of the stud to resist published loads.When installing to multi-ply 2x studs, the designer must specify the fasteners required to bindthe plys together and resist splitting.• Self-jigging models are designed to provide the required minimum end distance of 7 boltdiameters from the bottom of the stud or post to the centerline of the first bolt hole.• Tighten anchor bolt nuts to finger tight, plus 1/3 to 1/2 additional turns with a wrench. Woodmembers may shrink over time; if possible, nut tightness should be checked periodically. Toprevent loosening of the anchor bolt nut during critical loading, use a locking nut or tighten asecond nut over the first to lock nuts in place.• If used to anchor a built-up post, such as a double 2 x 4, the post component shall bedesigned to act as a single unit. Holdown fasteners specified shall not be considered to attachmultiple plys together.
continued on next page
Washer requiredunder anchor
bolt nut
TD15 = 3 3/8˝TD9 & TD12 = 3 1/2˝
Typical TDX2-TZback-to-backinstallation
Typical TD15installation
Typical TDX6installation
TDX6
Holdown installationbetween floors
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Holdowns – TD & TDX series
Enddist.
CLW D
H
3 1/2˝
9/16˝
USP2173-111
Hold
ow
ns
1-800-328-5934 • www.USPconnectors.com 39
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Sources of Deflection at the Shearwall Holdown Connections
1-800-328-5934 • www.USPconnectors.com
Holdowns – TD & TDX series continued
Ref. No. W H D CL Qty Dia. 160% ∆ (in)8 160% ∆ (in)
8 160% ∆ (in)8 160% ∆ (in)
8 160% ∆ (in)8
TD5 HD5 7 3 6-3/8 3-3/4 2-1/8 3/4 2 3/4 5-1/4 2405 0.122 6 4040 0.140 6 4040 0.140 6 -- -- -- -- 4040 0.140 6
TD7 HD7 7 3-3/8 11-7/8 3-5/8 2-1/8 1-1/8 3 7/8 6-1/8 4075 0.088 6 7805 0.121 6 9015 0.135 6 -- -- -- -- 9895 0.145 6
TD9 HD9 7 3-3/8 16-1/2 4-1/4 2-1/8 1-1/8 3 1 7 -- -- -- -- 8855 0.142 6 10225 0.155 6 12665 0.164 6 12785 0.165 6
TD12 HD12 3 3-1/2 20-1/2 4-1/4 2-1/8 1-1/8 4 1 7 -- -- -- -- 12070 0.132 6 13960 0.142 6 16550 0.185 6 16550 0.185 6
TD15 HD15 3 3-1/2 25 4-3/8 2-1/8 1-1/4 5 1 7 -- -- -- -- 14505 0.167 6 16845 0.178 6 17755 0.202 6 17755 0.202 6
TDX2-TZ HD2A, HD3B
12 2-1/16 8-1/8 2-3/4 1-1/2 5/8 2 5/8 4-1/2 1910 0.150 6 2345 0.167 6 3130 0.140 6 -- -- -- -- 3130 0.140 6
TDX5 HD5A 10 2-1/2 9-3/8 3-7/8 2 3/4 2 3/4 5-1/4 2350 0.134 9 3260 0.179 9 3260 0.179 9 -- -- -- -- 3260 0.179 9
TDX6 HD6A, HD5B
7 3-1/2 11-1/8 3-3/4 2 7/8 2 7/8 6-1/8 2765 0.0916 5320 0.180
6 5355 0.1826 -- -- -- -- 5355 0.182
6
TDX8 HD8A 7 3-1/2 14-5/8 3-3/4 2 7/8 3 7/8 6-1/8 4065 0.123 9 7120 0.180 9 7120 0.180 9 -- -- -- -- 7120 0.180 9
TDX10 HD10A, HD7B
7 3-1/2 18-1/8 3-3/4 2 7/8 4 7/8 6-1/8 5110 0.126 9 7845 0.181 9 7845 0.181 9 -- -- -- -- 7845 0.181 9
TDX14 HD14A, HD9B
3 3-1/2 20-1/2 3-5/8 2-1/8 1 4 1 7 6625 0.109 9 11995 0.170 9 13075 0.181 9 -- -- -- -- 13075 0.181 9
1) Allowable loads shown are for single shear connections and may be doubled for back-to-back installations. The designer must verify post and anchor bolt capacities. 2) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 3) The designer must specify stud or post to resist published load values. 4) The designer must specify anchor bolt type, length, and embedment. 5) All models may be installed with greater than the required anchor end distance with no chart load reduction. 6) Deflections are derived from static, monotonic load tests of devices connected to DF-L wood members and consider both the deflection of the holdown and cross grain crushing of the wood post. 7) The designer shall consider the effect of compression, bearing, tension, and combined bending due to device eccentricity when applicable. 8) Holdowns raised off of the sill plate may have higher deflection values. 9) Deflections are derived from static, monotonic load tests of devices connected to a steel jig. Additional deflection due to wood shrinkage and fastener slippage should be considered. New products or updated product information are designated in bold font.
Allowable DF / SP Tension Loads (Lbs.)1,2,3
Length of Bolt in Vertical Member
4-1/2"
20
1-1/2"
130
AnchorBoltDia.
CodeRef.
3" 3-1/2" 5-1/2"
Dimensions Fastener Schedule4
Min.RequiredBolt End
Distance5
USPStock No.11
SteelGauge
Bolts
The following are some of the sources of deflection that should be evaluated by the designer. See the illustration, which applies to otherholdown configurations.
A. Improperly-sized stud/post bolt holes – increased bolt slip can occur ifstud/post bolt holes are oversized and exceed the 2005 NDS® recommendedbolt hole diameter.
B. Stud/Post bolt holes – bolt slip can occur.
C. Wood crushing at stud/post bolt hole perimeters –the use of larger washers/bearing plates can reduce stress-induced woodcrushing at bolt bearing locations.
D. Eccentricity in stud/post caused by holdown –holdowns installed on only one side of a stud or post result in an eccentricitywhich causes increased stresses and movement in a shearwall system.
E. Nut spin – anchor bolt nuts that are not restrained can spin loose duringcyclic loading, allowing movement; the use of steel nylon locking nuts or threadadhesive may prevent nut spin.
F. Loose nuts – increased movement can occur when nuts are not sufficientlytightened.
G. Holdown deflection – holdown deflection can occur when the shearwallsystem is subjected to cyclic stress from earthquakes or high wind.
H. Wood Shrinkage – due to drying, wood may shrink and cause bolted connections to become loose; periodic retightening may be required.
I. Localized crushing at wood-bearing surfaces –excessive crushing at wood-bearing surfaces may result from compressiveforces due to overturning during high wind or earthquake loading.
A
ShearwallEnd Post
Bearing Plates
Holdown
WoodSill Plate
HoldownAnchor Bolt
FoundationConcrete
BC
E
D
F
HI
G
1-800-328-5934 • www.USPconnectors.com
Hold
ow
ns
1-800-328-5934 • www.USPconnectors.com40
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
Typical UPHDconcrete
wall installation
1-800-328-5934 • www.USPconnectors.comcontinued on next page
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Holdowns – UPHD series
Engineered for high capacity with minimum deflection and low eccentricity.
Materials: See chartFinish: USP primerCodes: ER-0200
Installation:• Use all specified fasteners. See Product Notes, page 11.• Place holdown over anchor bolt and drive screws into post.• Tighten anchor bolt nuts finger tight snug to base, plus 1/3 to 1/2 additional turns with awrench.To preventh loosening of the anchor nut during critical loading, use a locking night or tighten a second nut over the first to lock nuts in place.• Holdown may be installed off of the plate with no load reduction.• Post may be shimmed provided the shim acts as a single unit with the post. Holdown fasteners specified shall not be considered to attach shim to post. Shim shall be astructural material equal or better than the post material. Consult a designer or an engineerof record for appropriate fastening of shim.
Alternate installations:• Drill hole in concrete or masonry and insert retrofit anchor (i.e. epoxy anchor) capable ofresisting uplift and lateral loading.• Place holdown over anchor bolt and drive screws into post.• Tighten anchor bolt nuts finger tight snug to base, plus 2-3 additional turns with a wrench.To prevent loosening of the anchor nut during critical loading, use a locking nut or tighten a second nut over the first to lock nuts in place.• Post may be shimmed provided the shim acts as a single unit with the post. Holdown fasteners specified shall not be considered to attach shim to post. Shim shall be a structur-al material equal or better than the post material. Consult a designer or an engineer of recordfor appropriate fastening of shim.
Typical UPHDinstallation
DF-L / SP S-P-F
Ref. No. W H D CL Qty 160% 160%
UPHD8 HDQ8-SDS3 10 3-1/4 17-1/4 3-1/8 1-3/8 7/8 24 9165 0.075 7695
UPHD9 HDU11-SDS2.5 10 3-1/4 17-1/4 3-1/2 1-1/2 1 24 11270 0.057 9465
UPHD11 HHDQ11-SDS2.5 7 3 15-1/8 3-1/2 1-1/2 1 24 14395 0.077 12090
UPHD14 HDU14-SDS2.5, HHDQ14-SDS2.5
7 3 18-3/4 3-1/2 1-1/2 1 30 16695 0.082 14020
1) Allowable loads have been increased 60% for wind and seismic loads; no further increase shall be permitted. 2) The designer must specify anchor bolt type, length, and embedment. 3) Deflections are derived from static, monotonic load tests of devices connected to DF-L wood members with specified fasteners. 4) The designer shall consider the effect of compression, bearing, tension, and combined bending due to device eccentricity when applicable. 5) The UPHD may be elevated off the sill. 6) WS3 wood screws are 1/4 ˝ x 3˝ and are included with UPHD models. 7) Minimum post thickness is 3˝ or greater. Consult USP for installations less than 3˝. New products or updated product information are designated in bold font.
USPStock No.
SteelGauge
Dimensions Fastener Schedule
Anchor
Bolt Dia.2CodeRef.
Allowable Tension Loads (Lbs.)1,5,7
WS3 Wood
Screws6
20
∆ (in)
at 160%3,5
CL
D
H
WUPHD
NEWSIZE
Install (1) #4rebar in
shear cone12˝ Min.rebar length
30˝ Min.rebar length
1/2˝ Min. from corner
USP2173-111
Hold
ow
ns
1-800-328-5934 • www.USPconnectors.com 41
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
Typical HPAHD22single pour corner and
endwall installation
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Typical HPAHD22single pour rim joist
installation
(1) #4 rebarin shear
cone13 1/2˝
Nailedportion
1/2˝ min.from corner
2x embedmentlength + 12˝ Min.
rebar length Install (1)#4 rebar inshear cone
Typical HPAHD22single pour edge
installation
Foundation Straps – HPAHD series & PAHD42
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
HPAHD
continued on next page
Embedmentline
W
H1
H2
D
PAHD42
Designed to anchor wood framing to poured concrete foundations.
Materials: See chartFinish: G90 galvanizingCodes: NER 505, ESR-2787
Installation:• Use all specified fasteners. See Product Notes, page 11.• Bending the strap horizontally 90° to facilitate wall placement may cause concrete behind the embedded strap to break away at the top edge (spalling). If the spall is 1˝ or less from the top edge of the concrete, no load reduction is necessary. If the spall is between 1˝ and 4˝, the allowable load is 0.90 of the published chart load.• When installing on lumber less than 31⁄2˝ wide, wood splitting may occur. Toreduce splitting, use 10d x 11⁄2˝ nails or fill every other hole with 16d commonnails. Reduce allowable loads in accordance with code requirements. • Straps are to be installed at the edge of concrete. Install prior to pour by nailingto form. Drive temporary nails through lowest two nail holes into form. Concretelevel should reach embedment line; minimum embedment depths are listed inchart.• Do not rely on these straps to secure concrete sections together between coldjoints; take other measures to transfer the load. If there is a cold joint between slaband foundation, the minimum embedment must be made into the foundation.Fastening opportunities may be reduced because the slab pour level may be higher than some nail holes. Using fewer fasteners will reduce allowable loads.Reduce allowable load by the code capacity for each fastener not installed.• Allowable loads based on a minimum concrete compressive strength of 2,500 psiat 28 days, with one #4 horizontal rebar in the shear cone. Rebar should be a minimum length of 2x embedment depth plus 12˝ (see chart for exceptions in corner installations).• Where fewer fasteners are used in the structural wood member, reduce loads according to the code. • There may be an increase in the amount of deflection if the strap is installed onthe outside of the sheathing, versus directly to the framing members. For moreinformation, visit USP’s Web Site www.USPConnectors.com/techbulletins.htmland reference HPAHD/STAD Strap Anchors Installed Over Shear Wall DiaphramShearing document.• Strap may be bent one complete cycle to aid installation.
Embedmentline
W
H1
H2
D
H1
H2
D
W
HPAHD22 form boardinstallation
Hold
ow
ns
1-800-328-5934 • www.USPconnectors.com42
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Foundation Straps – HPAHD series & PAHD42 continued
Typical HPAHD22-2Pdouble pour corner
installation
4˝ slabInstall (1) #4rebar in
shear cone
Edge distance1/2˝ Min. from corner
4˝ slab
Install (1)4˝ rebarin shearcone
Stemwall width
Typical HPAHD22-2Pdouble pour edge
installation
Allowable Loads (Lbs.)1
DF-L /SP
Uplift
Ref. No. W H1 H2 D Nail 160%
68
L56
8
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) Nails require a minimum embedment length of 1-5/8˝ for 16d nails. 16d sinkers (0.148˝ diameter by 3-1/4˝ long) or 10d common nails may be substituted for the specified 16d common nails provided the listed alowable loads are reduced 15%. 3) Rim joist application; see Figure 3 for corner condition. 4) Minimum quantity of fasteners to be installed. Product may have additional nail holes not needed to meet published allowable load of product.
16d
16d
4095
Dimensions
StemwallWidth
Fastener
Schedule2
CodeRef.
Double Pour Edge Installation - 1/2˝ min from corner
Figure 56-1/4
USPStock No.
SteelGauge
InstallationType
MinQty4
EDGE INSTALLATION - 2500 psi Concrete
CORNER INSTALLATION - 2500 psi Concrete
HPAHD22-2P
Double Pour Edge Installation - 8˝ min from corner
HPAHD22-2P 10 2-1/16 517026-1/4 14 24
6-1/4 Figure 4 24 HPAHD22-2P HPAHD22-2P 10 2-1/16 26-1/4 14
H1
W
H2
D
Embedmentline
HPAHD22-2P
Min
Stemwall
ThicknessEdge
Qty Type W L IE D (in.) Distance 4,5 CD = 1.6 (lbs.)
Uncracked 3300 3300 2635
Cracked 2310 2310 1980Uncracked 3460 3460 2965
Cracked 2425 2425 2075Uncracked 1225 1225 1050
Cracked 855 855 735Uncracked 2610 2610 2140
Cracked 1830 1830 1565
1) A 16d Common nail has a diameter of 0.162 inch and a length of 3-1/2 inches. 2) Predrilled holes are not required 3) The lesser of the allowable load based on anchorage to concrete or wood connection strength must be selected. 4) An edge distance of 1/2" implies that the distance from the corner of the wall to the edge of the strap is no less than 1/2". 5) An edge distance of 1.5 x IE implies that the minimum distance from the corner of the wall to the centerline of the strap is no less than 1.5 times the embedment depth. 6) For edge distances between 1/2" and 1.5 x lE calculate loads using straight line interpolation. 7) Minimum anchor spacing for full capacity is 2 x lE . For spacing less than that reduce capacity proportionally. 8) The allowable loads are based on lumber with a specific gravity of 0.50 and a moisture content of 19% or less. 9) Deformation based on wood connection strength. 10) Minimum concrete strength f'c = 2500 psi 11) Minimum 1-#4 rebar shall be installed in the shear cone New products or updated product information are designated in bold font.
0.118
0.118
0.095
0.095
3830
3830
2065
2065
Allowable Uplift Loads (Lbs.) 3
Deflection atAllowable LoadBased on Wood
Connection
Strength (in.) 9
WoodConnection
Strength
Concrete Connection Strength
Dimensions (in.)
HPAHD22
CodeRef.
13
Seismic (lbs) 6,7,8
SDC C-FRef. No.
Schedule 1,2
Concrete 10, 11
6
1/2"
Wind (lbs)6,7,8
Seismic (lbs) 6,7,8
SDC A,B
Fastener
USPStock No
SteelGa.
HPAHD22 10 23 16d
21/16
21/16 24 3/4 91/2
16 5/8 8 PAHD42 12 15 16d PAHD42 53/4
1.5 x I E
1.5 x I E
6
1/2"
41/8
USP2173-111
Hold
ow
ns
1-800-328-5934 • www.USPconnectors.com 43
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
Install (1) #4rebar in
shear cone
12˝ Min.rebar length
Edge distance 1/2˝ Min.
from corner
The coined dimples below the embedment line allow for increased concrete bonding. These holdowns retainhigh uplift capacity even when installed at corners of foundation stemwalls. Ideal for use with built up 2x endposts.
RJ after the model indicates LSTAD or STAD for rim joist applications as in STAD8RJ. Rim joist models provide for a 17˝ clear span without the loss of strap nailing.
Materials: See ChartFinish: G90 galvanizingCodes: NER 608, ESR-2787
Installation:• Use all specified fasteners. See Product Notes, page 15. The bottom (2) nails are for form board attachment only and do not contribute to fastener schedule requirements.• Embed holdown in concrete to the embedment line (bend line).• See illustrations for requirements on rebar, edge distances, and clear spans.• Bending the strap horizontally 90° to facilitate wall placement may cause concrete behind the embeddedstrap to break away at the top edge (spalling). If the spall is 1˝ or less from the top edge of the concrete, noload reduction is necessary. If the spall is between 1˝ and 4˝ the allowable load is 0.90 of the published chartload.•When installing on lumber less than 31/2˝ wide, wood splitting may occur. To reduce splitting, use 10d x 11/2˝nails or fill every other hole with 16d common nails. Reduce allowable loads per code requirements accordingly.• These straps do not secure concrete sections together at cold joints; take other measures to transfer theload. If there is a cold joint between slab and foundation, the minimum embedment must be made into thefoundation. Fastening opportunities may be reduced because the slab pour level may be higher than somenail holes. Using fewer fasteners will reduce allowable loads. Reduce allowable load by the code capacity foreach fastener not installed.• To achieve full table loads the minimum center-to-center spacing is twice the embedment depth (IE) whenresisting tension loads at the same time.• Where fewer fasteners are used in the structural wood member, reduce loads according to the code.• There may be an increase in the amount of deflection if the strap is installed on the outside of the sheathing, versus directly to the framing members.• Strap may be bent one complete cycle to aid installation.
W
L
IE
CS
D
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Foundation Straps – LSTAD & STAD series
continued on next page
CS
L
IE
W
D
STAD
LSTAD
STAD_RJ
CS
W
D
L
IE
Nailedportion
CS Install (1)#4 rebar inshear cone
Edge distance1/2˝ Min. from corner
30˝ Min.rebar length
12˝ Min.rebar length
Typical STAD14RJcorner rim joist installation
2x embedment length,+ 12˝ Min. rebar length
Typical STAD10edge installation
Typical STAD10corner installation
Ref. No. Qty Nail W L LE D CS 1/2˝ 1-1/2˝ lE 1/2˝ 1-1/2˝ lE 1/2˝ 1-1/2˝ lE
6
8
6
8
1) Specified nails are 16d sinker nails. 10d common nails may be substituted with no load reduction. 2) Wood thickness shall be no less than 2˝. 3) Allowable tension loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 4) Interpolate allowable loads for edge distances between those listed. Nail quantities may be reduced for less than lE corner distance design loads- use the code allowable loads for fasteners in shear. 5) Where fewer fasteners are used in the structural wood member, reduce loads according to the code.
Dimensions
SteelGauge
14
Fastener Schedule1,2
USPStock No.
LSTAD8 LSTHD8 24
L8
16d Sinker
Allowable Tension Loads (160%)3,4,5
Edge Distance - Concrete
DF-L / SP
Min. Stemwall
CodeRef.
2000 psi 2500 psi 3000 psi
3 21-5/8 8 5 4-5/8 2225 2225 3220 2225 2225 3220 2225 2225 3220
LSTAD8RJ LSTHD8RJ 14 24 16d Sinker 3 35-1/8 8 5 18-1/8 2225 2225 2225 2225 32203220 2225 2225 3220
Hold
ow
ns
1-800-328-5934 • www.USPconnectors.com44
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com
W
L1
L
2 1/4˝
TA
Foundation Straps – TA series
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Typical TAstud to foundation
installation
1-800-328-5934 • www.USPconnectors.com
Foundation Straps – LSTAD & STAD series continued
Foundation Straps offer an economical, one-piece method ofachieving a continuous load path from a 2 x 8, 2 x 10, 2 x 12, or 2 x 14 rim joist through concrete block to foundation. All modelsrequire a 6˝ embedment into concrete footings.
Materials: 12 gaugeFinish: G90 galvanizingCodes: NER 505
Installation:• Use all specified fasteners. See Product Notes, page 11.• Allowable loads are based on either nail fastening or bolt fastening; nail and bolt values cannot be combined.• Install by inserting product into footing’s wet concrete. All modelsrequire a 6˝ embedment into concrete foundations. Courses ofconcrete block must be laid over connector. Notch mudsill at connector locations. Wrap strap over rim joist and fasten.• Do not rely on these straps to secure concrete sections togetherbetween cold joints; take other measures to transfer the load. Ifthere is a cold joint between block and foundation, the minimumembedment must be made into the foundation.• Based on product embedment the exposed number of fastenerholes may be reduced. Using fewer fasteners will reduce allowableloads. Reduce allowable loads by the code prescribed allowable loadper fastener, for each fastener not installed.• Allowable loads are based on a minimum concrete compressivestrength of 2,000 psi at 28 days.
Double 2 X 10rim joist
6˝ Min.
Double 2 X 10rim joist
Typical TAinstallation
continued on next page
Min
Stemwall
ThicknessEdge
Ref. No. Qty Type W L IE D (in.) Distance 5,6 CD = 1.6 (lbs.)
Uncracked 2405 2405 2060
Cracked 1685 1685 1445Uncracked 3930 3930 3060
Cracked 2805 2805 2405
Uncracked 2405 2405 2060Cracked 1685 1685 1445
Uncracked 3930 3930 3060Cracked 2805 2805 2405
Uncracked 2405 2405 2060
Cracked 1685 1685 1445Uncracked 3930 3930 3060
Cracked 2805 2805 2405Uncracked 2405 2405 2060
Cracked 1685 1685 1445
Uncracked 3930 3930 3060Cracked 2805 2805 2405
Uncracked 5035 5035 4030Cracked 3525 3525 3020
Uncracked 5580 5580 4345
Cracked 4270 4270 3660Uncracked 5035 5035 4030
Cracked 3525 3525 3020
Uncracked 5580 5580 4345Cracked 4270 4270 3660
1) A 16d Sinker nail has a diameter of 0.148 inch and length of 3-1/4 inches. 2) Predrilled holes are not required 3) When 16d Sinker nails are specified, 10d Common nails may be substituted with no load reduction. 4) Wood thickness shall be no less than 3 inches (2 - 2x members) 5) An edge distance of 1/2" implies that the distance from the corner of the wall to the edge of the strap is no less than 1/2". 6) An edge distance of 1.5 x IE implies that the minimum distance from the corner of the wall to the centerline of the strap is no less than 1.5 times the embedment depth. 7) For edge distances between 1/2" and 1.5 x lE calculate loads using straight line interpolation. 8) Minimum anchor spacing for full capacity is 2 x lE . For spacing less than that reduce capacity proportionally. 9) The allowable loads are based on lumber with a specific gravity of 0.50 and a moisture content of 19% or less. 10) Deformation based on wood connection strength. 11) The lesser of the allowable load based on anchorage to concrete or wood connection strength must be selected.. 12) Minimum concrete strength f'c = 2500 psi 13) Minimum 1-#4 rebar shall be installed in the shear cone New products or updated product information are designated in bold font.
0.104
Concrete Connection Strength 10
4700
4700
4700
4700
4700
4700
4700
Deflection atAllowable LoadBased on Wood
Connection
Strength (in.) 10
0.115
0.115
0.115
0.115
CodeRef.
13
6
1/2"
1.5 x I E
4685
4685
4685
4685
0.115
3 32-1/8 14 5 STAD14 12 38 16d Sinker STHD14
3 21-5/8 10 5 STAD10 12 28 16d Sinker
WInd (lbs)7,8,9
5 6
1/2"
1.5 x I E
Concrete12,13
Allowable Uplift Loads (lbs.) 11
Seismic (lbs) 7,8,9
SDC C-FSeismic (lbs) 7,8,9
SDC A,B
Wood ConnectionStrength
USPStock No
SteelGa.
STAD8 12 24 16d Sinker 3 21-5/8 8
5 6
1/2"
1.5 x I E
6
1/2"
1.5 x I E
1/2"
1.5 x I E
16d Sinker 3 39-5/8 14 STAD14RJ STHD14RJ 12 38
36 10 5 6
0.104
0.104
0.104
6
1/2"
1.5 x I E
0.1154700
0.115
0.115
STAD8RJ 8 5
STAD10RJ STHD10RJ 12 28 16d Sinker 3
3 35-1/8
Fastener
STHD8
STHD10
STHD8RJ 12 24 16d Sinker
Schedule 1,2,3
Dimensions (in.)
USP2173-111
1-800-328-5934 • www.USPconnectors.com 45
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
Purlin Anchors – HPA, PA & PAI series
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Foundation Straps – TA series continued
HPA series – For installation into poured concrete walls, foundations, or masonry.The HPA is the heavy-duty version of the PA anchor.
PA series – For installation into poured concrete or concrete block walls and foun-dations. PAI series – For wood I-Joist applications. An expanded 3˝ on-center nail spacingreduces splitting along I-Joist flange.
Materials: HPA – 10 gauge; PA & PAI – 12 gaugeFinish: G90 galvanizing
Options: PA18 & PA28 are available in Triple Zinc. To order, add TZ to end of stock number, as in PA18-TZ.
Codes: NER 505
Installation:• Use all specified fasteners. See Product Notes, page 11.• Minimum concrete strength is 2,000 psi.• The allowable loads for bolts are based on parallel to grain loading with a 3˝ minimum member thickness, except the HPA which requires a 31⁄2˝ thick woodmember. Reduce load per code requirements when minimum member thickness is not achieved.• Minimum concrete edge distance is 4˝ for PA & PAI series, and 6˝ for HPA series. • Minimum concrete block edge distance is 20˝.• Designer may specify alternate fastening schedules. Refer to Nail SpecificationTable on page 15 for nail shear values. Load values shall not exceed publishedallowable loads.• No anchor bolts are needed for achieving efficient stress transfer from framing toconcrete walls or foundations.
L
1 1/2˝
2 1/16˝
4 1/2˝
PA / HPA
L
2 1/16˝
PAI
continued on next page
Uplift3 Uplift3 Uplift3 Uplift3
W L L1 Qty Type 160% Qty Type 160% Qty Type 160% Qty Type 160%
TA51 PA51 48-1/4 TA71 PA68 68-1/4
TA51 PA51 48-1/4
TA71 PA68 68-1/4
1) Bolt values are for 3˝ thick rim joist loaded perpendicular to grain. 2) 16d x 2-1/2 nails are 8 gauge (0.162" diameter) by 2-1/2˝ long. 3) Uplift loads have been increased 60% for wind and seismic loads; no further increase shall be permitted. 4) Minimum of (9) 16d nails per strap is required to meet IRC R 404.1.5.
22-1/8
Fastener
Schedule1,2
Fastener
Schedule1,2
Fastener
Schedule1,2
1/2 1/2 24751340 4
323016d x 2-1/2 16d x 2-1/2 16d x 2-1/2102-1/16
2-1/16 2 3
Nail Uplift Values & Schedules for Rim Joist Sizes Below
3230
1905 32308 14
Allowable Loads (Lbs.)
Bolt Uplift Values & Schedules for Rim Joist Sizes Below
Dimensions
2 x 142 x 8 2 x 10 2 x 12
USPStock No.
Ref.No.
Fastener
Schedule1,2
22-1/8
CodeRef.
L5
1950 1/2 1/26
16 16d x 2-1/22385
1-800-328-5934 • www.USPconnectors.com
Hold
ow
ns
Hold
ow
ns
Purlin Anchors – HPA, PA & PAI continued
1-800-328-5934 • www.USPconnectors.com46
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
Diaphragm to wall anchorage using embeddedstraps may need to be hooked around the concrete or masonry wall reinforcing steel. IBC 1620.2.1.
4 Min. concrete20˝ Min. concrete block
edge distance
Ledger
#4 rebarmin.
4˝
Typical PAI I-Joist purlinface installation
Typical PA holdowninstallation
Typical PA purlininstallation
Nails Bolts2Nails Bolts 2
Ref. No. L Qty Nail Qty Dia. 160% 160% 160% 160%
Max Capacity
2x & 3x Ledger4x Ledger
Max Capacity2x & 3x Ledger
4x Ledger
Max Capacity
2x & 3x Ledger
4x Ledger
Max Capacity2x & 3x Ledger
4x LedgerMax Capacity
2x & 3x Ledger
4x LedgerMax Capacity
2x & 3x Ledger4x Ledger
Max Capacity 2475
2x & 3x Ledger4x Ledger 2270
Max Capacity 37002x & 3x Ledger 3510
4x Ledger 3095
Max Capacity2x & 3x Ledger
4x LedgerMax Capacity
2x & 3x Ledger
4x Ledger
1) Allowable Loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) The allowable loads for bolts are based on parallel-to-grain loading with 3˝ minimum member thickness, except HPA which requires a 3-1/2˝ thick wood member. 3) Allowable loads are based on the use of either nails or bolts; nail and bolt values cannot be combined. 4) 16d sinkers or 10d common nails may be substituted for the specified 16d common nails at 0.85 of the table loads. 5) Minimum nail penetration is 1-5/8˝ for 16d nails. 6) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 7) For alternate nail schedule and load values consult USP. 8) Minimum quantity of fasteners to be installed. Product may have additional fastener holes not needed to meet published allowable load of product.
CodeRef.
-- --
-- --10d x 1-1/2
16d
-- --
-- --
16d
3035
3035
Con
cret
e
Mas
onry
Allowable Loads (Lbs.)1,3
Concrete
Min Qty8
Fastener Schedule7
DF-L / SP
MinimumEmbedment
NailerSize
Nails4,5,6
3700
4
1/2
1/2
16d
16d
3
6
3035
3035
1855
3035
3035
3035
-- --
-- --
-- --
-- --
3035
3700
-- --
-- --
-- --
-- --
2475
3700
1/2
23 4 54251/2
1/2
26 -- --
-- --
18 -- --
24
10d x 1-1/2
10d x 1-1/2
23
6
8
8
303515 4 37003700 303516d
6
PAI28 PAI28 28-1/2 4
PAI35 PAI35 35-1/2
6
4
PAI23 PAI23 23-1/2 4
PAI18 PAI18 18-1/2 4
HPA35 HPA35 35 6
HPA28 HPA28 29 6
PA28 PA28, PAT28
PA35 PA35
PA23 PA23, PAT23
23-3/4 4
USPStock No.
PA18, PAT18
18-1/2 PA18
Bolts
22603035 303522601/2
Masonry
29 4 6
35 4 6
12 2
15
16d
6
12 -- --10d x 1-1/26
4
15 4 3700 30353700
L5
3035
3265 3035
4280
42805055
2 1/2˝
3/4˝
L
DW
CL
Cold Formed Steel Holdowns – HTT14S, LTS20B, & TDS series
Typical TDL5interior installation
USP2173-111
Hold
ow
ns
1-800-328-5934 • www.USPconnectors.com 47
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Concrete Angles – TDL series
TDL10
H
D
W
These angles secure wood posts to concrete or wood floorsin light-duty applications.
Materials: 12 gaugeFinish: G90 galvanizingCodes: ER-2039
Options: TDL5 is available in Triple Zinc. To order, add TZ to end of stock number, as in TDL5-TZ.
Installation:• Use all specified fasteners. See Product Notes, page 11.• The TDL10 can be embedded into concrete. Minimum embedment depth is 4˝ to achieve allowable loads.• Moisture barrier may be required.
Anchor Bolts
Nails Bolts
Ref. No. W H D Qty Dia. Qty Type Qty Dia. 160% 160%
TDL5 A24 12 2 5-3/16 2-1/4 1 1/2 4 16d 1 1/2 TDL10 A311 12 2 9-3/4 2-1/4 1 1/2 4 16d 1 1/2
1) Allowable loads are based on the use of either nails or bolts; nail and bolt values cannot be combined. 2) The bolt values are based on single shear with a minimum member thickness of 3-1/2˝. 3) Allowable loads have been increased in accordance with the code; no further increase shall be permitted. 4) Minimum nail embedment shall be 1-5/8˝ for 16d nails. 5) Designer must specify anchor bolt type, length, and embedment.
955 1105
Bolts
Strap
L2
USPStock No.
Dimensions
Nails
CodeRef.
Fastener Schedule4,5 Allowable Loads (Lbs.)1,2,3
Uplift
SteelGauge
DF-L / SP
Typical TDL10embedded interior
installation
4˝ Min.
HTT14S
LTS20B
Narrow width
allows for easy fit
insidestud
section
STBAnchors
Boltpages28-29
CLD
L3 3/4˝
6 1/4˝
W
1/4˝ transfer
plateTypical cold-formed steel installation
(TD8S product shown)
LTS20B – Light capacity tension tie strap with a 1/4˝ load transfer plate.
HTT14S – Medium capacity single piece, 3-ply base, formed tension tie.
TDS – Heavy capacity tension tie with single piece formedback and welded base plate.
Materials: See chartFinish: TDS models – USP primer,
HTT14S and LTS20B – G90 galvanizing
Installation:
• Use all specified fasteners. See Product Notes, page 11.• See STB series, pages 28-29, for anchor bolt installation options. A design professional may specify alternate anchorage with conventional anchor bolts.• Tighten anchor bolt nuts finger tight snug to base, plus 1/3to 1/2 additional turns with a wrench. To prevent loosening ofthe anchor nut during critical loading, use a locking night ortighten a second nut over the first to lock nuts in place.
TD8S
D
2 1/4˝
W
3/8˝
L
CL
Ref. No. Strap Base W L D CL Qty Dia. Qty Type 100% 160% 100% 160% 100% 160%
HTT14S S/HTT14 10 -- -- 2-13/16 14-5/8 2-1/16 1-3/8 1 5/8 14 #10 2480 3290 3680 4425 4825 4825
LTS20B S/LTT20 12 3 2 20 3 1-1/2 1 1/2 5 #10 885 1140 1090 1090 1210 1210
TD8S S/HD8S 10 3/8 2-1/2 13-7/8 3 1-5/8 1 7/8 24 #10 4655 6210 8110 9665 10310 10310 TD10S S/HD10S 10 3/8 2-1/2 16-1/8 3 1-5/8 1 7/8 30 #10 5820 7760 10140 11525 12910 12910
TD15S S/HD15S 7 1/2 2-5/8 21-1/2 3 1-11/16 1 1 48 #10 9310 12270 14345 14345 16585 16585
1) Back-to-back stud members are required unless otherwise noted. 2) The allowable loads at 160% can only be used with codes that permit the use of alternate basic load combinations and when the referenced materials standard permits it. 3) Designer shall specify anchor embedment and configuration. 4) Designer shall verify the adequacy of the steel studs to transfer the required load. New products or updated product information are designated in bold font.
CodeRef.
To Stud
Screws
110
2-33 mil (2-20ga)Back-to-Back Studs
2-43 mil (2-18ga)Back-to-Back Studs
2-54 mil (2-16ga)Back-to-Back Studs
Allowable Tension Loads (Lbs.)1,2,3,4Fastener Schedule
USPStock No.
Steel Gauge Dimensions
Anchor Bolts
To Sill Plate
Caps &
Bases
48
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com
KECCQ
KLCC
EPB
KCBQ CBE
PA PA(E) PAU
WAS
EBG44-TZ
D
CPB
EPCM
KCCQ
PB
WE
CBSQ
Post Anchors . . . . . . . . . . . . . . . . . . Page 49• PA, PA(E), & PAU SeriesAdjustable wood to concrete post base with 1˝ stand-off fastens withanchor bolt.
Wet Post Anchors . . . . . . . . . . . . . . Page 50• WAS SeriesWood-to-concrete post base with 1˝ stand-off installs in wet concrete.
• WE SeriesWood-to-concrete post base installs in wet concrete.
Elevated Post Bases. . . . . . . . . . . . Page 51• EBG44-TZ & EPB Series Elevated post bases with tube support allowing for up to 1˝ clearance.
Post Anchors . . . . . . . . . . . . . . . . . . Page 52• D SeriesLight capacity post anchor nails to post and base.
Column Bases . . . . . . . . . . . . . Pages 52-53• CBSQ SeriesHigh capacity column base with 1˝ stand-off fastens to column with WSWood Screws.
• KCBQ SeriesHigh capacity column base fastens to column with WS Wood Screws.
• CBE SeriesLight capacity column base bolts or nails to column.
Post Caps . . . . . . . . . . . . . . . . . Pages 54-56• EPCM & PCM Series Medium-capacity post to beam connector.
• C, PB, PBES, & PBS SeriesLight-capacity post to beam connector.
• PBC SeriesLight-capacity corner post to beam connector.
Composite Post Bases . . . . . . . . . . Page 56• CPB SeriesElevated post base to avoid moisture from ground contact.
Lally Column Caps . . . . . . . . . Pages 56-57• KLCC SeriesConnects lally columns to beams.
Column Caps . . . . . . . . . . . . . . Pages 57-58• KCCQ & KECCQ Series
Heavy-capacity column to beam connector fastens to column and beam
with WS Wood Screws.
PBCPBES PBS
1-800-328-5934 • www.USPconnectors.com
Caps & Bases
CPCMNails Bolts
Ref. No. W H L Qty Dia. Qty Type Qty Dia. 100% 160% 160%
4 x 4 PA44 AB44 18 12 3-9/16 2-1/8 3-1/2 1 1/2 8 16d -- -- -- -- 5135 380 -- --
4 x 4 Rough PA44R 18 12 4-1/16 3-1/2 4 1 1/2 12 16d -- -- -- -- 5135 380 -- --
4 x 6 PA46 AB46 18 12 3-9/16 3-1/2 5-1/2 1 1/2 14 16d -- -- -- -- 6285 505 -- --
4 x 6 Rough PA46R 18 10 4-1/16 3-1/2 6 1 1/2 14 16d -- -- -- -- 6285 505 -- --
6 x 6 PA66 AB66 18 12 5-9/16 3-1/2 5-1/2 1 1/2 16 16d -- -- -- -- 6950 470 -- -- 6 x 6 Rough PA66R AB66R 18 12 6-1/16 3-1/4 6-1/16 1 1/2 16 16d -- -- -- -- 6950 470 -- --
PA44E 6 16d
PA44E-GC -- -- 6 N16C-GC
PA46E 8 16d
PA46E-GC -- -- 8 N16C-GC
PA66E 8 16d
PA66E-GC -- -- 8 N16C-GC 4 x 4 PAU44 ABU44 12 16 3-9/16 5-7/16 3 1 5/8 12 16d 2 1/2 6775 2535 2265 6, F4, F15, D4, R13
4 x 6 PAU46 ABU46 10 12 3-9/16 6 5 1 5/8 12 16d 2 1/2 13815 2535 2265 6, F15, R13 6 x 6 PAU66 ABU66 10 12 5-1/2 6 5 1 5/8 12 16d 2 1/2 16005 2380 2265 6, F4, F15, D4, R13
8 x 8 PAU88 ABU88 12 12 7-1/2 7-3/16 7-1/16 2 5/8 14 16d -- -- -- -- 24900 3185 -- -- 8 x 8 Rough PAU88R ABU88R 12 12 8-1/16 6-15/16 7-1/16 2 5/8 14 16d -- -- -- -- 24900 3185 -- --
Post Anchors are used to secure wood posts to concrete footings. These post anchors also provide moisture damage protection and feature a 1˝ stand-off plate to elevate wood posts above concrete surfaces.
PA(E) – 2-sided post anchors with high uplift and bearing capacity.
PA – High capacity utilizing 4-sided design.
PAU – Higher uplift resistance and optional bolt fastening to post.
Materials: See chartFinish: G90 galvanizing, PA_E-GC models - Gold Coat
Options: PA44, PA46, PA66, PA44E, PA46E, PA66E, PAU44, PAU46, PAU66 & PAU88 are available in Triple Zinc. To order, add TZ tostock number, as in PA44-TZ.PAU44, PAU46, PAU66 & PAU88 are available in Stainless steelTo order, add SS to stock number, as in PAU44-SS.
Codes: ESR-1881, ESR-1831, FL569, FL821, FL822, FL11910 Dade County, FL 07-0306.06,L.A. City RR 25779, L.A. City RR 25836
Installation: • Use all specified fasteners. Install with supplied washer. See Product Notes, page 11.• Anchor bolts and nails are not furnished.• Not recommended for fence posts or other unrestrained (not fixed or fastened at top)applications. These anchors are not designed to resist overturning (moment) loads.• Anchor bolt installation – position specified 5/8˝ diameter anchor bolt at desired location with minimum 4˝ embedment into 2000 psi concrete. A minimum 2˝ edge distance is required to achieve allowable loads.• For hardened concrete or retrofit installations – use 5/8˝ diameter threaded rod with USP’s CIA-EAor CIA-GEL 7000 adhesive, follow installation instructions.
Typical PAinstallation
USP2173-111
Caps &
Bases
1-800-328-5934 • www.USPconnectors.com 49
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
® Typical PA44Einstallation
Post Anchors – PA, PA(E), & PAU series
2˝
2 3/4˝
H
LW
PA
PAU
PAUcross-section
Stand-off plate
Washer
Base
The codes specify that non decay resistant columns exposed toweather or located in basements or cellars must be supported bypiers or metal pedestals projecting 1-inch above floor or finished grade. IRC R319.1.4, IBC 2304.11.2.7.
The codes specify that structural columns shall be fastened to resist net induced uplift forces and prevent lateral displacementat the bottom end. IRC R407.3, IBC 2304.9.7.
Bearing
Nails Bolts
Ref. No. Base W H L Qty Dia. Qty Type Qty Dia. 100% 160% 160%
4 x 4 PA44 AB44 18 12 3-9/16 2-1/8 3-1/2 1 1/2 8 16d -- -- -- -- 5135 380 -- --
4 x 4 Rough PA44R AB44R, ABE44R
18 12 4-1/16 3-1/2 4 1 1/2 12 16d -- -- -- -- 5135 380 -- --
4 x 6 PA46 AB46 18 12 3-9/16 3-1/2 5-1/2 1 1/2 14 16d -- -- -- -- 6285 505 -- --
4 x 6 Rough PA46R AB46R, ABE46R
18 10 4-1/16 3-1/2 6 1 1/2 14 16d -- -- -- -- 6285 505 -- --
6 x 6 PA66 AB66 18 12 5-9/16 3-1/2 5-1/2 1 1/2 16 16d -- -- -- -- 6950 470 -- -- 6 x 6 Rough PA66R AB66R 18 12 6-1/16 3-1/4 6-1/16 1 1/2 16 16d -- -- -- -- 6950 470 -- --
PA44E ABA44, ABE44
6 16d
PA44E-GC -- -- 6 N16C-GC
PA46E ABA46, ABE46
8 16d
PA46E-GC -- -- 8 N16C-GC
PA66E ABA66, ABE66
8 16d
PA66E-GC -- -- 8 N16C-GC 4 x 4 PAU44 ABU44 12 16 3-9/16 5-7/16 3 1 5/8 12 16d 2 1/2 6775 2535 2265 6, F4, F15, D4, R13
4 x 6 PAU46 ABU46 10 12 3-9/16 6 5 1 5/8 12 16d 2 1/2 13815 2535 2265 6, F15, R13 6 x 6 PAU66 ABU66 10 12 5-1/2 6 5 1 5/8 12 16d 2 1/2 16005 2380 2265 6, F4, F15, D4, R13
8 x 8 PAU88 ABU88 12 12 7-1/2 7-3/16 7-1/16 2 5/8 14 16d -- -- -- -- 24900 3185 -- -- 8 x 8 Rough PAU88R ABU88R 12 12 8-1/16 6-15/16 7-1/16 2 5/8 14 16d -- -- -- -- 24900 3185 -- --
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) Minimum nail embedment shall be 1-5/8˝ for 16d nails and N16C-GC. 3) All bolts shall meet or exceed the specifications of ASTM A 307. 4) Allowable loads are based on the use of either nails or bolts; nail and bolt values cannot be combined.
USPStock No.
Dimensions Fastener Schedule2,3
Post
Steel Gauge
Stand-offPlate
Anchor Bolt
1 1/216
Allowable Loads (Lbs.)4
Uplift1DF-L / SP
-- --
4 x 6
6 x 6
18
18
14
4 x 4
12 3-9/16 3-1/2 5-1/2
12 5-1/2 3-1/2 5-1/2
1
1 -- -- 16005
138155/8
5/8
-- --
-- --
-- --
Post/Column Size
CodeRef.
6775 990
Nails Bolts
-- --3-9/16 3-1/2 3-1/2
10, F16,R14
825
1060
-- --
-- --
6, F15, R13
130
10, F16,R14
-- --
Caps &
Bases
1-800-328-5934 • www.USPconnectors.com50
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®Wet Post Anchors – WAS & WE series
WAS – A formed base providing a 1˝ stand-off with high bearing capacity.
WE – A formed, one-piece design. Includes embossing for additional lateralstrength.
Materials: See chartFinish: G90 galvanizing
Options: WAS44, WAS46, WAS66, WE44, WE46, & WE66 are available in Triple Zinc. To order, add TZ to stock number, as in WAS44-TZ.
Codes: NER 530 & NER 608, ER-2039
Installation:• Use all specified fasteners. See Product Notes, page 11. • Insert into wet concrete after the pour. For the WE, embed the anchor so that thebase plate is flush with the surface of the concrete. For the WAS, embed theanchor until the concrete surface meets the bottom edge of the stand off baselegs. This will provide a 1˝ stand-off where required. A 2˝ minimum edge distanceis required to achieve allowable loads. • Not recommended for fence posts or other unrestrained (not fixedor fastened at top) applications. These anchors are not designed to resist overturning (moment) loads.
Ref. No. Base Strap W1 W2 H1 H23L Qty Type Bearing F1 F2 Uplift1
12 16d 1180 1135 1405
2 1/2 1020 910 1430
4 x 4 Rough
WE44R PB44R 12 12 4 -- -- 5 3-5/8 3-3/8 12 16d -- -- 1180 1135 1405 L2
12 16d -- -- 1180 1135 1405
2 1/2 1020 910 1430
4 x 6 Rough
WE46R -- -- 12 12 6 -- -- 5 3-5/8 3-3/8 12 16d -- -- 1180 1135 1405 L2
6 x 6 WE66 PB66 12 12 5-1/2 -- -- 5 3-5/8 5-3/8 12 16d -- -- -- -- 2860 2100 L2
6 x 6 Rough
WE66R PB66R 12 12 6 -- -- 5 3-5/8 5-3/8 12 16d -- -- -- -- 2860 2100 L2
14 16d 1405 1300 2600
2 1/2 1415 1300 260014 16d 1405 1300 2600
2 1/2 1485 1300 2600
14 16d 2100 1540 32952 1/2 2165 1540 4370
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) Allowable loads are based on the use of either nails or bolts; nail and bolt values cannot be combined. 3) H2 is mimimum embedment length of anchor into concrete. 4) Minimum nail embedment shall be 1-5/8˝ for 16d nails. 5) Minimum concrete compressive strength shall be 2,000 psi at 28 days. 6) All bolts shall meet or exceed the specifications of ASTM A 307.
USPStock No.
PostSize
DF-L / SP (160%)
DimensionsSteel Gauge Fastener Schedule4,6 Allowable Loads (Lbs.)2
CodeRef.
6775
13815
16005
-- -- L6
L6
L8
L8
L8
4 x 4 WE44
WE46 4 x 6
4 x 4
4 x 6
6 x 6
WAS44
WAS46
WAS66
PBS46
PBS66
16
12
12
14
14
12
PB44 12 12
PB46 12 12
PBS44A
3-1/2
5-1/2
4-3/4 3-3/8-- --
-- --
3-1/4
4-3/4 3-3/8 3-1/4
6-3/4
6-3/4
6-3/4
3-1/2 2-1/4
3-1/2 2-1/4
2-1/45
3-1/2
5-1/2
5-1/25-1/2
3-9/16
3-9/16
2˝ Min. edge distance
W1
H1
H2
L
Typical WEinstallation WE
L
H1
W2
W1
11 3/16˝
H2
WAS
Uplift
1˝ Stand-offplate2˝ Min.
edgedistance
F1F2
Typical WASinstallation
The codes specify that non decay resistant columnsexposed to weather or located in basements or cellarsmust be supported by piers or metal pedestals projecting 1-inch above floor or finished grade.IRC R319.1.4, IBC 2304.11.2.7.
The codes specify that structural columns shall be fastened to resist net induced uplift forces and preventlateral displacement at the bottom end. IRC R407.3, IBC 2304.9.7.
These post bases allow installers to pre-align posts and preset post heightsabove concrete floors or footings. By eliminating post-to-concrete contact,moisture damage is reduced.
EPB – Welded and primed.
EBG44 – Galvanized for added corrosion resistance.
Materials: EPB – 14 gauge tube; 14 gauge steel U-bracketEBG44 – 16 gauge tube; 16 gauge steel U-bracket
Finish: EPB – USP primer;EBG44 – G-185 galvanizing
Options: EPB4408, EPB4608, and EPB6608-HDG are available in hot-dipped galvanized. To order, add HDG to stock number, as in EPB4408-HDG.
Codes: NER 505
Installation:• Use all specified fasteners. See Product Notes, page 11.• These post bases allow installers to pre-align posts and preset post heights above concrete floors or footings. By eliminating post-to-concrete contact, moisture damage is reduced. • Not recommended for fence post or other fixed post applications. These anchors are not designed to resist overturning (moment) loads.
F1
F2
Uplift
Bearing
3˝ Min. edgedistance
Typical EPBinstallation
Elevated Post Bases – EBG44 & EPB series
L
H1
H2
W
EBG/EPB similar
F11 F21Bearing Uplift2
Ref. No. W L H1 H2 Qty Nail 160% 160% 100% 160%
4 x 4 EPB4408 EPB44, EPB44-12
3-9/16 3 3 8 8 16d 1115 1075 3045 1140
4 x 6 EPB4608 EPB46, EPB46-12
3-9/16 5 3 8 12 16d 2330 1695 3045 1560
6 x 6 EPB6608 EPB66, EPB66-12
5-9/16 5 3-3/16 8 12 16d 2330 1695 4665 1560
4 x 4 EBG44-TZ EPB44A 3-9/16 2-3/4 2-3/8 7-1/2 8 16d HDG 1100 1180 2485 1085
1) Lateral loads (F1 and F2) are for conditions where pipe extends no more than 1˝ above the concrete surface. 2) Uplift Loads have been increased 60% for wind and seismic loads; no further increase shall be permitted. 3) Minimum nail embedment shall be 1-5/8˝ for 16d nails.
PostSize
CodeRef.
L5
USPStock No.
Dimensions Allowable Loads (Lbs.)
DF-L / SP
Fastener
Schedule 3
1˝ Max.elevation
Typical EBG44-TZinstallation
The codes specify that non decay resistant columns exposed toweather or located in basements or cellars must be supported bypiers or metal pedestals projecting 1-inch above floor or finished grade. IRC R319.1.4, IBC 2304.11.2.7.
The codes specify that structural columns shall be fastened to resist net induced uplift forces and prevent lateral displacementat the bottom end. IRC R407.3, IBC 2304.9.7.
USP2173-111
Caps &
Bases
1-800-328-5934 • www.USPconnectors.com 51
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
CBE – 12 gauge base for carports, patios, or other residentialframing.
KCBQ – High capacity base fastens with WS Wood Screws.
Materials: See chartFinish: G90 galvanizing
Options: KCBQ models available in rough/full sizes. KCBQ44, KCBQ46, KCBQ66, and KCBQ88available in Hot-dip galvanized. To order, addHDG to stock number, as in KCBQ44-HDG.
Codes: NER 530, ICBO 2725
Installation:• Use all specified fasteners. See Product Notes, page 11.• WS2 Wood Screws, 1/4˝ dia. x 2˝ long, are supplied with
KCBQ Column Bases.• Not recommended for fence posts or other unrestrained
(not fixed or fastened at top) applications. These bases are not designed to resist overturning (moment) loads.
• All models require a minimum edge distance of 3˝.• Bolted models feature diamond holes for temporary
nail fastening to facilitate drilling and bolting. • Embed column base with bottom of base plate flush to
concrete.
2˝ or 3˝Min.edge distance
KCBQ66
H
L
W2W1
8˝
Typical KCBQ66 installation
Caps &
Bases
1-800-328-5934 • www.USPconnectors.com52
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®Column Bases – CBE & KCBQ series
W2
3 3/16˝
L
H
7˝
W1
CBETypical CBEinstallation
DF-L / SP
Ref. No. Strap Base W1 W2 H L Qty 160%
2 1/2 438012 16d 2820
KCBQ44 CB44, CBQ44-SDS2
10 7 3-9/16 3-1/2 8-3/4 2-1/4 14 WS2 6870 L3
2 1/2 437012 16d 2820
KCBQ46 CBQ46-SDS2 10 7 3-9/16 5-1/2 8-3/4 2-1/4 14 WS2 6870 L3 4 x 8 KCBQ48 CB48 10 7 3-9/16 7-1/2 8-3/4 2-1/4 14 WS2 6870
6 x 4 KCBQ64 CB64 10 7 5-1/2 3-1/2 8-3/4 2-1/4 14 WS2 68702 1/2 4360
12 16d 2820
6 x 6 KCBQ66 CB66, CBQ66-SDS2
10 7 5-1/2 5-1/2 8-3/4 2-1/4 14 WS2 6870 L3
6 x 8 KCBQ68 CB68 10 7 5-1/2 7-1/2 8-3/4 2-1/4 14 WS2 6870
7-1/8 x 3-1/2 KCBQ71-4 CB71/8-4 10 7 7-1/8 3-1/2 8-3/4 2-1/4 14 WS2 6870 7-1/8 x 5-1/2 KCBQ71-6 CB71/8-6 10 7 7-1/8 5-1/2 8-3/4 2-1/4 14 WS2 6870
7-1/8 x 7-1/8 KCBQ71-7 CB71/8-7 10 7 7-1/8 7-1/8 8-3/4 2-1/4 14 WS2 6870 8 x 6 KCBQ86 CB86 10 7 7-1/2 5-1/2 8-3/4 2-1/4 14 WS2 6870
8 x 8 KCBQ88 CB88 10 7 7-1/2 7-1/2 8-3/4 2-1/4 14 WS2 6870
10 x 10 KCBQ1010 CB1010 10 7 9-1/2 9-1/2 8-3/4 2-1/4 14 WS2 6870 10 x 12 KCBQ1012 CB1012 10 7 9-1/2 11-1/2 8-3/4 2-1/4 14 WS2 6870
12 x 12 KCBQ1212 CB1212 10 7 11-1/2 11-1/2 8-3/4 2-1/4 14 WS2 6870
5-1/8 glulam
KCBQ5 CB5-4.5, CB5-6
10 7 5-1/4 Spec. 8-3/4 2 14 WS2 6870
6-3/4 glulam
KCBQ7 CB7-6, CB7-7.5, CB7-9, CB7-10.5
10 7 6-7/8 Spec. 8-3/4 2 14 WS2 6870
8-3/4 glulam
KCBQ9 CB9-6, CB9-7.5, CB9-9, CB9-10.5
10 7 8-7/8 Spec. 8-3/4 2 14 WS2 6870
1) Allowable loads are based on the use of either nails or bolts; nail and bolt values cannot be combined. 2) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 3) WS2 Wood Screws are 1/4˝ dia. x 2˝ long and are included with KCBQ Column Bases. 4) All bolts shall meet or exceed the specifications of ASTM A 307. 5) Minimum nail embedment shall be 1-5/8˝ for 16d nails. 6) Concrete compressive strength shall be 2,000 psi or greater at 28 days. New products or updated product information are designated in bold font.
4 x 4
4 x 6
130
2
2
L6
L6 LCB46 CBE46
3-9/16 3-1/2 7-1/2
5-1/2 7-1/2
2 L6
12 12
12 7-1/25-1/2 5-1/2
3-9/16
6 x 6 CBE66 LCB66 12
Allowable Uplift
Loads (Lbs.)1,2
130
130
CodeRef.
Glulam Sizes
1212 LCB44 CBE44
Fastener
Schedule 3,4,5,6
Type
ColumnSize
USPStock No.
Steel Gauge Dimensions
The codes specify that structural columns shall be fastened to resist net induced uplift forces and prevent lateral displacementat the bottom end. IRC R407.3, IBC 2304.9.7.
3˝Min.edge distance
3˝ Min. edgedistance
1˝ standoffThese column bases install using USP’s WS2-HDG Wood Screws,
reducing installation time and cost. Designed for high uplift in high wind orseismic applications. Includes a stand-off plate to protect the wood fromground contact moisture.
Materials: See chartFinish: G-185 galvanizing
Installation:• Use all specified fasteners. See Product Notes, page 11.• WS2-HDG Wood Screws, 1/4˝ dia. x 2˝ long, are supplied with CBSQBases.• All models require a minimum edge distance of 3˝.•Embed the column base until the concrete surface meets the bottom edge of the stand-off plate.• Not recommended for fence posts or other unrestrained (not fixedor fastened at top) applications. These bases are not designed toresist overturning (moment) loads.
USP2173-111
Caps &
Bases
53
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®Column Bases – CBSQ series
Post Anchors – D series
Secures nominal sized posts to wood surfaces for light-duty applications.
Materials: 18 gaugeFinish: G90 galvanizing
Options: D46 & D66 are available in Triple Zinc. To order, add TZ to stock number, as in D46-TZ.
Codes: ESR-1280, L.A. City RR 25749, FL11664
F1 F2 Uplift F1 F2 Uplift
Post Size Ref. No. W H L Qty Nail Qty Nail 160% 160% 160% 160% 160% 160%
4 x 4 D44-TZ BC40, BC40Z
18 3-9/16 2-1/2 3-3/8 8 16d HDG 4 16d HDG 875 875 715 750 750 565
4 x 4 Rough D44R BC40R 18 4 3 3-3/4 8 16d 4 16d 875 875 715 750 750 565
4 x 6 D46 BC460 18 3-9/16 3 5-3/8 10 16d 5 16d 1020 1095 715 855 920 600 6 x 6 D66 BC60 18 5-1/2 3 5-3/8 10 16d 5 16d 1020 1095 715 855 920 600
6 x 6 Rough D66R BC60R 18 6 3 5-3/8 10 16d 5 16d 1020 1095 715 855 920 600
8 x 8 Rough D88 BC80 18 8 3 7-3/8 12 16d 5 16d 1020 1095 715 855 920 600
1) Minimum nail embedment shall be 1-1/2˝ for 10d nails and 1-5/8˝ for 16d nails.
CodeRef.
2, F20,R12
S-P-F
Allowable Loads (Lbs.)
USPStock No.
SteelGauge
Dimensions
DF-L / SP
Fastener Schedule1
Post Beam
L
H
W
D
Typical D installation
Uplift1
Ref. No. Strap Base W1 W2 H L Qty 160%
4 x 4 CBSQ44-TZ CBS44, CBSQ44-SDS2
10 16 3-9/16 3-1/2 8-3/4 2-1/4 14 WS2-HDG 6775 6870
4 x 6 CBSQ46-TZ CBS46, CBSQ46-SDS2
10 12 3-9/16 5-7/16 8-3/4 2-1/4 14 WS2-HDG 13815 6870
6 x 6 CBSQ66-TZ CBS66 CBSQ66-SDS2
10 12 5-1/2 5-7/16 8-3/4 3 14 WS2-HDG 16005 6870
1) Uplift Loads have been increased 60% for wind and seismic loads, no further increase shall be permitted. 2) WS2-HDG Wood Screws are 1/4˝ x 2˝ and are included with CBSQ Column Bases. 3) Concrete compressive strength shall be 2,000 psi or greater at 28 days. New products or updated product information are designated in bold font.
FastenerSchedule 2,3
WoodScrews
ColumnSize
USPStock No.
Steel Gauge Dimensions
CodeRef.
130
Allowable Loads (Lbs.)
Bearing100%
DF-L / SP
CBSQ44-TZ
W2
W1
L
H
7 3/16˝
The codes specify that nondecay resistant columnsexposed to weather or locatedin basements or cellars mustbe supported by piers or metalpedestals projecting 1-inchabove floor or finished grade.IRCR319.1.4, IBC2304.11.2.7.
The codes specify that structural columns shall be fastened to resist net induceduplift forces and prevent lateral displacement at the bottom end. IRC R407.3, IBC 2304.9.7.
Installation:• Use all specified fasteners. See Product Notes, page 11.• Not recommended for fence posts or other unrestrained (not fixedor fastened at top) applications. These anchors are not designed toresist overturning (moment) loads.• While D series post anchors offer some lateral and uplift resistance, theyare not recommended as a primary means of anchorage for posts in railings. They may be used only for intermediate posts between fullyanchored corner / end posts in rail systems.
1-800-328-5934 • www.USPconnectors.com
Typical CBSQ44-TZinstallation
Caps &
Bases
1-800-328-5934 • www.USPconnectors.com54
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®Post Caps – EPCM & PCM series
PCM EPCM
F1 F2 Uplift1 F1 F2 Uplift1
Ref. No. Beam Post W1 W2 H1 L1 L2 L3 160% 160% 160% 160% 160% 160%
PCM4416 PC44-16 4x 4x 3-9/16 3-9/16 3-9/16 2-7/16 11 7-1/4 1300 1480 1100 1300 1480 1100
PCM44 PC44 4x 4x 3-9/16 3-9/16 3-9/16 2-7/16 11 7-1/4 1545 1850 1900 1545 1850 1900 PCM46 PC46 4x 6x 3-9/16 5-9/16 3-9/16 2-7/16 13 9-1/4 1545 1850 1900 1545 1850 1900
PCM4616 PC46-16 4x 6x 3-9/16 5-9/16 3-9/16 2-7/16 13 9-1/4 1300 1480 1100 1300 1480 1100 PCM4816 PC48-16 4x 8x 3-9/16 7-9/16 3-9/16 2-7/16 15 11-1/4 1300 1480 1100 1300 1480 1100
PCM48 PC48 4x 8x 3-9/16 7-9/16 3-9/16 2-7/16 15 11-1/4 1545 1850 1900 1545 1850 1900
PCM6416 PC64-16 6x 4x 5-1/2 3-9/16 3-1/2 3-13/16 11 7-1/4 1765 1765 1120 1765 1765 1120 PCM64 PC64 6x 4x 5-1/2 3-9/16 3-1/2 3-13/16 11 7-1/4 2115 1905 1795 1905 1905 1795
PCM6616 PC66-16 6x 6x 5-1/2 5-9/16 3-1/2 3-13/16 13 9-1/4 1765 1765 1120 1765 1765 1120 PCM66 PC66 6x 6x 5-1/2 5-9/16 3-1/2 3-13/16 13 9-1/4 2115 1905 1795 1905 1905 1795
PCM6816 -- -- 6x 8x 5-1/2 7-9/16 3-1/2 3-13/16 15 11-1/4 1765 1765 1120 1765 1765 1120 PCM68 PC68 6x 8x 5-1/2 7-9/16 3-1/2 3-13/16 15 11-1/4 2115 1905 1795 1905 1905 1795
PCM77 -- -- 7-1/8 7-1/8 7-1/8 7-1/8 3-11/16 5-5/8 14-9/16 10-13/16 2115 1905 1795 1905 1905 1795
PCM8416 -- -- 8x 4x 7-1/2 3-9/16 3-1/2 5-5/8 11 7-1/4 1765 1765 1120 1765 1765 1120 PCM84 PC84 8x 4x 7-1/2 3-9/16 3-1/2 5-5/8 11 7-1/4 2115 1905 1795 1905 1905 1795
PCM8616 -- -- 8x 6x 7-1/2 5-9/16 3-3/8 5-5/8 13 9-1/4 1765 1765 1120 1765 1765 1120 PCM86 PC86 8x 6x 7-1/2 5-9/16 3-1/2 5-5/8 13 9-1/4 2115 1905 1795 1905 1905 1795
PCM8816 -- -- 8x 8x 7-1/2 7-9/16 3-1/2 5-5/8 15 11-1/4 1765 1765 1120 1765 1765 1120
PCM88 PC88 8x 8x 7-1/2 7-9/16 3-1/2 5-5/8 15 11-1/4 2115 1905 1795 1905 1905 1795
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted.
5,F30,R5
CodeRef.
PCM EPCM
Dimensions Allowable Loads (Lbs.)
USPStock No.
DF-L / SP
PCM – Provides a positive connection for medium-duty, post-to-beam applications.
EPCM – End column caps.
Materials: See chartFinish: G90 galvanizing
Options: PCM4416, PCM4616 & PCM6616 are availablein Triple Zinc. To order, add TZ to stock number,as in PCM4416-TZ. To order for end post applications, add E to thebeginning of the part number, as in EPCM4416.
Codes: ESR-1781, FL13285, L.A.City RR 25843
Installation:• Use all specified fasteners. See Product Notes, page 11.• PCM 16 gauge post caps should not be substituted for PCM 12gauge post caps unless approved by the Engineer of Record.
3 3/4˝
H1
W1
L2
L1W2
Uplift
F1
F2
PCMTypical PCM46
installation
Typical EPCMinstallation
3 3/4˝
H1
W1L3
L1W2
EPCM
Ref. Series Post Beam
PCM_16 PC_16 16 (8) 16d (12) 16d
PCM PC 12 (8) 16d (12) 16d
EPCM_16 EPC_16 16 (8) 16d (8) 16d
EPCM EPC 12 (8) 16d (8) 16d 1) Minimum nail embedment shall be 1-5/8˝ for 16d nails.
USPSeries
SteelGauge
Fastener Schedule1
1-800-328-5934 • www.USPconnectors.com
USP2173-111
Caps &
Bases
1-800-328-5934 • www.USPconnectors.com 55
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com
H2
W1
L1W2
L2
H1
Uplift F1 F2
Post Size Ref. No. W1 W2 H1 H2 L1 L2 Qty Type Qty Type 160% 160% 160%
4 x 4 C44 BC4 18 3-9/16 3-9/16 2-7/8 2-7/8 3-1/4 3-1/4 6 16d 6 16d 1000 1225 1225 2, F4, F20, D4, R12
4 x 4 Rough C44R BC4R 18 4 4 2-5/8 2-5/8 3-1/4 3-1/4 8 16d 8 16d 1000 1225 1225 2, F20, R12
4 x 6 C46 BC46 18 3-9/16 5-1/2 2-9/16 2-5/8 3-3/8 5-1/4 6 16d 10 16d 1000 1225 1225 2, F4, F20, D4, R12
4 x 6 Rough C46R -- -- 18 4 6 2-3/4 2-3/4 3-1/4 5-1/4 8 16d 10 16d 1000 1225 1225 2, F20, R12
6 x 6 C66 BC6 18 5-1/2 5-1/2 2-7/8 2-7/8 5-1/4 5-1/4 12 16d 12 16d 1295 2190 2190 2, F4, F20, D4, R12
6 x 6 Rough C66R BC6R 18 6 6 2-13/16 2-13/16 5-1/4 5-1/4 10 16d 10 16d 1090 2190 2190 2, F20, R12
8 x 8 C88 BC8 18 7-1/2 7-1/2 5 5 7-3/8 7-3/8 16 16d 16 16d 1125 2525 2525 2, F4, F20, D4, R12
PB44-6TZ2
LPC4, LPC4Z 18 1-1/2 -- -- 2-1/8 1-1/2 3-5/8 -- -- 8 16d HDG 8 16d HDG 640 1000 400
PB44-6GC2 -- -- 18 1-1/2 -- -- 2-1/8 1-1/2 3-5/8 -- -- 8 N16C-GC 8 N16C-GC 640 1000 400
PB66-6TZ 2 LPC6Z 1-1/2 -- -- 2-1/2 3 5-9/16 -- -- 8 16d HDG 8 16d HDG 640 1000 400
PB66-6GC2 -- -- 1-1/2 -- -- 2-1/2 3 5-9/16 -- -- 8 N16C-GC 8 N16C-GC 640 1000 400
4 x 4 PBES442 ACE4 18 1-1/2 -- -- 2-3/8 2-3/4 3-1/4 4-3/4 8 16d 8 16d 1755 1015 630
6 x 6 PBES662 ACE6, LCE4 18 1-1/2 -- -- 2-3/8 2-1/8 5-1/2 7 8 16d 8 16d 1755 1275 1010
4 x 4 PBS442 AC4 18 1-7/16 -- -- 2-5/16 2-13/16 3-9/16 6-1/2 12 16d 12 16d 2630 1730 1195
4 x 4 Rough PBS44R2 AC4R 18 1-1/2 -- -- 2-5/16 2-3/16 4 7 8 16d 8 16d 1755 1015 630
6 x 6 PBS662 AC6 18 1-1/4 -- -- 2-5/16 2-7/8 5-1/2 8 14 16d 12 16d 2280 1850 1310
6 x 6 Rough PBS66R2 AC6R 18 1-1/4 -- -- 2-5/16 2-3/16 6 8-1/2 10 16d 10 16d 1845 1275 1010
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) Load and nail schedules for two-piece models are per pair of post caps. 3) Minimum nail embedment shall be 1-5/8˝ for 16d and N16C-GC nails.
USPStock No.
SteelGauge Code Ref.
Allowable Loads (Lbs.)1
DF-L / SP
Dimensions Fastener Schedule3
Post Beam
4 x 4 - 6
6 x 6 - 6 18
5, F30, R5
C44
L1
H1
W1
H2
PB44-6TZ
C – One-piece design.
PB – Two-piece design.
PBES & PBS – Two-piece design with extended side plates and wrap around postdesign. Easy retrofit installations.
Materials: 18 gaugeFinish: G90 galvanizing;
PB44-6TZ & PB66-6TZ – G185 galvanizing; PB44-GC & PB66-6GC – Gold Coat
Options: C44, C46, C66, PBES44, & PBES66 are available in Triple Zinc. To order, add TZto stock number, as in PBS44-TZ.C44, PBES44, & PBES66, PBS44, & PBS66 areavailable in Stainless steel. To order, add SS to stock number,as in C44-SS.
Codes: ESR-1280, ESR-1781,L.A. City RR 25749, FL569, FL11664, FL13285, Dade County, FL 07-0306.06L.A. City RR 25843
Typical PB-TZinstallation
H1 W1L1
L2
H2
Uplift
F1
F2
PBES
Typical PBSinstallation
Post Caps – C, PB, PBES, & PBS series
L2
L1
H1
W1
H2
PBS
Typical PBESinstallation
Typical C44installation
Installation:• Use all specified fasteners. See ProductNotes, page 11.• These products are designed to work withsingle, solid-sawn beams, but can be used withbuilt-up beams. When installed to multiplebeams made up of 2x lumber and shims, fastenthe plys and shims together to act as a unit.
The CPB is made of corrosion resistant composite material compatible with preservative treated lumber. Provides coderequired 1˝ stand-off and can be used with rough lumber sizes.
Materials: High Strength composite
Installation:• Attach base to post with (4) 10d HDG nails.• Attach post to concrete using 1/2˝ diameter rod into concrete andextend into wood member.• Not recommended for fence posts or other unrestrained (notfixed or fastened at top) applications. These anchors are notdesigned to resist overturning (moment) loads.
Caps &
Bases
1-800-328-5934 • www.USPconnectors.com56
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
Typical PBCinstallation
PBC
Post Beam Corner – PBC series
Typical KLCCinstallation
CPBRef. No. W1 W2 Qty Nail
4 x 4 CPB44 CPS4 3-1/4 3-1/4 2.2 4 10d HDG 5235 6545 4 x 6 CPB46 CPS46 3-5/16 5-5/16 3.3 4 10d HDG 6810 9820
5 x 5 CPB55 CPS5 4-1/8 4-1/8 3.0 4 10d HDG 6295 8925 6 x 6 CPB66 CPS6 5-5/16 5-5/16 3.9 4 10d HDG 8570 11600
8 x 8 CPB88 CPS7 7-1/4 7-1/4 6.4 4 10d HDG 12490 19040
1) Loads shall not be increased for short-term loading.
2) Loads require a minimum 650 psi wood compressive strength.
3) Concrete Design Bearing Strength = Ø (0.85 f'C A1) with f'C = 2,500 psi. ACI 318-02, Section 10.17.1.
4) Design Bearing Strength has been increased assuming (A2 / A1)0.5
per ACI 318-02, Section 10.17.1.
PostSize
CodeRef.
100
ConcreteDesign Bearing
Strength 3,4
BottomSurface
Bearing AreaUSP
Stock No.
Dimensions Post BaseAllowableCapacity1,2
FastenerSchedule
W1W2
1˝
The PBC series is a one-piece connector designed to secure twomitered beams on a corner post while providing uplift capacity.
Materials: 18 gaugeFinish: G-185 galvanizing
Installation:• Use all specified fasteners. See Product Notes, page 11.• Install PBC on outside corner of post forming tabs to inner sideof post.• Assumes beam members are bevel cut at corner.
Composite Post Bases – CPB series
F1 F2 Uplift F1 F2 Uplift
Ref. No. W L Qty Type Qty Type 160% 160% 160% 160% 160% 160%
4 x 4 PBC44-TZ -- -- 18 4-15/16 6-1/2 8 16d HDG 8 16d HDG 870 870 1740 750 750 1500
6 x 6 PBC66-TZ -- -- 18 6-15/16 6-1/2 8 16d HDG 8 16d HDG 870 870 1740 750 750 1500
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 3) Minimum nail embedment shall be 1-5/8˝ for 16d nails.
Fastener Schedule2Dimensions Allowable Loads (Lbs.)1
S-P-FPost Beam
CodeRef.
130
PostSize
DF-L / SP
USPStock No.
SteelGauge
continued on next page
The codes specify that non decayresistant columns exposed to weatheror located in basements or cellars mustbe supported by piers or metalpedestals projecting 1-inch above flooror finished grade. IRC R319.1.4, IBC 2304.11.2.7.
The codes specify that structuralcolumns shall be fastened to resist netinduced uplift forces and prevent lateral displacement at the bottom end.IRC R407.3, IBC 2304.9.7
W
H
L
KLCC
1-800-328-5934 • www.USPconnectors.com
Lally Column Caps – KLCC series
Lally Column Caps connect lally columns to wood beams. Fits 31/2˝ and 4˝ diameter lally columns.
Materials: 12 gaugeFinish: USP primer
Installation:• Use all specified fasteners. See Product Notes, page 11.• Fit KLCC onto lally column. Position wood beam in KLCC saddle and fasten.
Typical CPBinstallation
USP2173-111
Lally Column Caps – KLCC series continuedC
aps &
Bases
57
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
continued on next page
Girder
Ref. No. W H L Qty Qty Type DF / SP / S-P-F LVL / PSL
KLCC45-35 LCC4.5-3.5 12 4-5/8 4 11-1/2 Triple 2x10/12 8 16d 3-1/2 16000 -- --
KLCC45-4 LCC4.5-4 12 4-5/8 4 11-1/2 Triple 2x10/12 8 16d 4 21000 -- --
KLCC6-35 LCC6-3.5 12 6-1/8 4 11-1/2 Quad 2x10/12 8 16d 3-1/2 16000 -- -- KLCC6-4 LCC6-4 12 6-1/8 4 11-1/2 Quad 2x10/12 8 16d 4 21000 -- --
KLCC35-35 LCC3.5-3.5 12 3-5/8 4 11-1/2 3.5 LVL / PSL 8 16d 3-1/2 -- -- 16000 KLCC35-4 LCC3.5-4 12 3-5/8 4 11-1/2 3.5 LVL / PSL 8 16d 4 -- -- 21000
KLCC525-35 LCC5.25-3.5 12 5-3/8 4 11-1/2 5.25 LVL / PSL 8 16d 3-1/2 -- -- 16000
KLCC525-4 LCC5.25-4 12 5-3/8 4 11-1/2 5.25 LVL / PSL 8 16d 4 -- -- 21000 KLCC7-35 LCC7-3.5 12 7-1/8 4 11-1/2 7 LVL / PSL 8 16d 3-1/2 -- -- 16000
KLCC7-4 LCC7-4 12 7-1/8 4 11-1/2 7 LVL / PSL 8 16d 4 -- -- 21000
CodeRef.
130
Allowable Loads (Lbs.)1,2,3,4Dimensions
USPStock No.
SteelGauge
ColumnOutside
Dia.
Fastener Schedule
Nails5
Typical KECCQ44end cap
installation
W1L
H
W2KCCQ44
Column Caps – KCCQ & KECCQ series
Designed to be installed without the need to drill bolt holes, simplifying installation and maintainingthe wood cross section. Installs with WS Wood Screws offering high uplift capacity.
Materials: See chartFinish: USP primer
Options: See Speciality Options on page 58. KCCQ325-4, KCCQ325-6, KCCQ44, KCCQ46, KCCQ525-4, KCCQ525-6, KCCQ64, KCCQ66, KECCQ325-4, KECCQ325-6, KECCQ44, KECCQ46, KECCQ525-6, KECCQ64, and KECCQ66 are available in Hot-dip galvanized. To order, add HDG to stock number, as in KCCQ44-HDG.
Codes: ESR-1465, FL817
Installation:• Use all specified fasteners. See Product Notes, page 11.• WS3 Wood Screws, 1/4˝ dia. x 3˝ long, are supplied with Column Caps.• Beams shall be designed to support the required loads. Beam shear may limit loads to less than listed oads for device. A design professional shall determine the adequacy of the stud to resist published loads.• For end column caps, add an E after the K in the stock number, as in KECCQ325-4.
Typical KCCQ44center capinstallation
1) Loads may not be increased for short-term loading. 2) Loads are for a continuous beam. 3) Allowable loads are determined using the lowest of the bearing loads. Use Fc equal to 335 psi for SPF, 625 psi for DF and 650 psi for LVL/PSL, or the lally column capacity. 4) Spliced conditions must be detailed by the designer to transfer tension loads between spliced members by means other than the lally column. The splice condition load is 6750 lbs. per beam side and the lally cap must be evenly loaded. 5) Minimum nail embedment shall be 1-5/8˝ for 16d nails.
KCCQ KECCQ KCCQ KECCQ
Ref. No. W1 W2 H KCCQ KECCQ Qty Type Qty Type 100% 100% 160% 160%
KCCQ325-4 CC31/4-4, CCQ3-4SDS2.5 7 3-1/4 3-5/8 6-1/2 11 7-1/2 16 WS3 14 WS3 21485 14650 7390 7105
KCCQ325-6 CC31/4-6, CCQ3-6SDS2.5 7 3-1/4 5-1/2 6-1/2 11 7-1/2 16 WS3 14 WS3 21485 14650 7390 7105 KCCQ44 CC44, CCQ44SDS2.5 7 3-5/8 3-5/8 6-1/2 11 8-1/2 16 WS3 14 WS3 24065 16965 7390 7105
KCCQ45 -- -- 7 3-5/8 5-3/8 6-1/2 11 7-1/2 16 WS3 14 WS3 24065 16405 7390 7105 130
KCCQ46 CC46, CCQ46SDS2.5 7 3-5/8 5-1/2 6-1/2 11 8-1/2 16 WS3 14 WS3 24065 18595 7390 7105 11, F12
KCCQ47 -- -- 7 3-5/8 7-1/8 6-1/2 11 9-1/2 16 WS3 14 WS3 24065 20780 7390 7105 KCCQ47X -- -- 7 3-5/8 7-1/8 6-1/2 13 9-1/2 16 WS3 14 WS3 28440 20780 7390 7105
KCCQ48 CC48, CCQ48SDS2.5 7 3-5/8 7-1/2 6-1/2 11 8-1/2 16 WS3 14 WS3 24065 18595 7390 7105
KCCQ525-4 CC51/4-4, CCQ5-4SDS2.5 3 5-1/4 3-5/8 8 13 9-1/2 16 WS3 14 WS3 41640 22330 7390 7105 KCCQ525-6 CC51/4-6, CCQ5-6SDS2.5 3 5-1/4 5-1/2 8 13 9-1/2 16 WS3 14 WS3 41640 27300 7390 7105
KCCQ525-8 CC51/4-8, CCQ5-8SDS2.5 3 5-1/4 7-1/2 8 13 9-1/2 16 WS3 14 WS3 41640 30430 7390 7105 KCCQ57 CC6-71/8 7 5-3/8 7-1/8 6-1/2 11 9-1/2 16 WS3 14 WS3 36095 27890 7390 7105 130
KCCQ64 CC64, CCQ64SDS2.5 7 5-1/2 3-5/8 6-1/2 11 8-1/2 16 WS3 14 WS3 37815 23535 7390 7105
KCCQ66 CC66, CCQ66SDS2.5 7 5-1/2 5-1/2 6-1/2 11 8-1/2 16 WS3 14 WS3 37815 28910 7390 7105 KCCQ67X CCQ6-7.13SDS2.5 7 5-1/2 7-1/8 6-1/2 11 8-1/2 16 WS3 14 WS3 37815 29220 7390 7105
KCCQ68 CC68, CCQ68SDS2.5 7 5-1/2 7-1/2 6-1/2 11 8-1/2 16 WS3 14 WS3 37815 29220 7390 7105 KCCQ74 CC74 3 6-7/8 3-5/8 6-1/2 11 8-1/2 16 WS3 14 WS3 46405 27465 7390 7105
KCCQ76 CC76, CCQ76SDS2.5 3 6-7/8 5-1/2 6-1/2 11 8-1/2 16 WS3 14 WS3 46405 35860 7390 7105
KCCQ77 CC77, CCQ77SDS2.5 3 6-7/8 6-7/8 6-1/2 11 8-1/2 16 WS3 14 WS3 46405 35860 7390 7105 KCCQ78 CC78, CCQ78SDS2.5 3 6-7/8 7-1/2 6-1/2 11 8-1/2 16 WS3 14 WS3 46405 35860 7390 7105
KCCQ71-4 CC71/8-4, CCQ7.1-4SDS2.5 3 7-1/8 3-5/8 6-1/2 11 8-1/2 16 WS3 14 WS3 48125 28240 7390 7105
KCCQ71-6 CC71/8-6, CCQ7.1-6SDS2.5 3 7-1/8 5-1/2 6-1/2 11 8-1/2 16 WS3 14 WS3 48125 35285 7390 7105
KCCQ71-71 CC71/8-71/8, CCQ7.1-7.1SDS2.5 3 7-1/8 7-1/8 6-1/2 11 8-1/2 16 WS3 14 WS3 48125 37190 7390 7105 11, F12
KCCQ71-8 CCQ7.1-8SDS2.5 3 7-1/8 7-1/2 6-1/2 11 8-1/2 16 WS3 14 WS3 48125 37190 7390 7105 130
KCCQ84 CC84 7 7-1/2 3-5/8 6-1/2 11 8-1/2 16 WS3 14 WS3 51565 29785 7390 7105 130 KCCQ86 CC86, CCQ86SDS2.5 7 7-1/2 5-1/2 6-1/2 11 8-1/2 16 WS3 14 WS3 51565 37390 7390 7105
KCCQ88 CC88, CCQ88SDS2.5 7 7-1/2 7-1/2 6-1/2 11 8-1/2 16 WS3 14 WS3 51565 39845 7390 7105
KCCQ94 CC94 7 8-7/8 3-5/8 6-1/2 11 8-1/2 16 WS3 14 WS3 60155 33595 7390 7105 130 KCCQ96 CC96, CCQ96SDS2.5 7 8-7/8 5-1/2 6-1/2 11 8-1/2 16 WS3 14 WS3 60155 42630 7390 7105
KCCQ98 CC98, CCQ98SDS2.5 7 8-7/8 7-1/2 6-1/2 11 8-1/2 16 WS3 14 WS3 60155 46485 7390 7105 KCCQ106 CC106, CCQ106SDS2.5 7 9-1/2 5-1/2 6-1/2 11 8-1/2 16 WS3 14 WS3 65315 45760 7390 7105
1) Bearing loads are based on 625 psi perpendicular to grain loading; no further increase for duration of load is permitted. 2) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 3) Allowable loads are based on lumber with a specific gravity of 0.50 and a moisture content of 19% or less. 4) WS3 Wood Screws are 1/4˝ x 3˝ long and are included with KCCQ and KECCQ column caps. 5) Beams shall be designed to support the required loads. Beam shear may limit loads to less than listed loads for device. 6) The designer shall check post for required loads. 7) Spliced conditions must be detailed by the specifier to transfer tension loads between spliced members by means other than the column cap. 8) Uplift loads do no apply to splice conditions.
USPStock No.
SteelGauge
Dimensions
Columnor Post
Fastener Schedule4
BeamL
Allowable Loads (Lbs.)3
Bearing1
DF-L / SP
CodeRef.
Uplift2,8
11, F12
11,F12
11,F12
130
11,F12
130
11, F12
W1L
H
W2
KECCQ44
1-800-328-5934 • www.USPconnectors.com
Speciality Options:• For end column caps, add an E after the K in the stock number, as in KECCQ325-4.• Straps may be rotated 90° on special order where the W2 dimension is less than or equal to the W1dimension.• KCCQ/KECCQ – Cap only, no strap design for field welding to pipe or other columns.• KCCQB – For cross beam connections. Any two buckets can be welded together for a wide variety ofapplications. Allowable load shall be the lesser of the two components.• KCCQT – For T beam intersections, consult USP. Specify beam/column conditions, dimensions, andloading requirements.• KCCQC – For X beam intersections, consult USP. Specify beam/column conditions, dimensions, andloading requirements.• KECCQLL/R – For L beam intersections, consult USP. Specify left (L) or right (R) beam/column condi-tions, dimensions, and loading requirements.
Dimension call-outs not shown in the table must be specified at time of ordering for spe-cialty options, non-catalog, or rough/full size lumber sizes.
CCaappss &&
BBaasseess
1-800-328-5934 • www.USPconnectors.com58
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
H
L
W1
4˝Typ.
W1
L
H1
H2H3
W2
W3
W4
KCCQC
1/4˝ unlessotherwise specified
Optional KECCQRotated Straps 90°
H2
W3
W2
4˝ Typ.
H1
W1
KECCQLLleft shown KCCQO
L2
L1
W2
H2
H1
KCCQOB
Top View of Specialty Options Column Cap Configurations
Column Caps – KCCQ & KECCQ series continued
W3
W2
H2
H1
L
W1
KCCQT
KECCQLLrotated 90° left
KECCQLRrotated 90° right
left right KECCQoffset left
KECCQoffset right
KCCQoffset left
KCCQoffset right
KECCQrotated 45° left
KECCQrotated 45° right
USP2173-111
An
gle
s &
Stra
ps
1-800-328-5934 • www.USPconnectors.com 59
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
B
BL
A3 AC
Framing Plates & Angles . . . . .Pages 62-66• MPA SeriesMulti-purpose framing angles.
• MP SeriesField adjustable framing angle.
• MP_F SeriesMulti-purpose framing plate.
• RBC SeriesReversed field adjustable framing.• A3 & AC SeriesFraming angles for joist support.
• JA SeriesHeavier-capacity framing angle for joist support.
Stud Plate Ties . . . . . . . . . . . . . . . . .Page 67• RSPT SeriesFlat stud to plate connector.
• SPT & SPTH SeriesU-shaped stud to plate connector.
Header Hangers . . . . . . . . . . . . . . . . . . . .Page 68• HH SeriesHeavy-capacity header hanger.
Lateral Joist Connectors . . . . . . . . . . Page 68• LJC-TZ SeriesSill plate to floor joist connectors.
• LJQ SeriesHigher cpacity sill plate to floor joist connector.
Miscellaneous . . . . . . . . . . . . .Pages 69-71• KHL SeriesHeavy-capacity corner-framing angle.
• ANJ44S-HDGHeavy-capacity corner-framing angle.
• B & BL SeriesL-shaped corner braces.
• L & T SeriesMedium and heavy-capacity L and T-shaped straps.
• Ornamental SeriesConnectors with ornamental notching.
MPA1
RSPT
ANJ44S-HDG
T L KHL33-O
HH
KHL
SPT
MP_F
JA
SPT SPTH
MP34 MP
Angles & Straps
continued on next page
LJC-TZ LJQ-TZ
RBC
An
gle
s &
Str
ap
s
1-800-328-5934 • www.USPconnectors.com60
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
LFTA6 LTW MTW/HTW
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Coiled Strapping . . . . . . . . . . . . . . .Page 72• CMST & CMSTC Series3˝ wide coiled strapping.
• RS Series11⁄4˝ wide coiled strapping.
Straps . . . . . . . . . . . . . . . . . . . .Pages 73-76• LSTA, MSTA, & ST Series11⁄4˝ wide flat strapping.
• KST & KSTI Series21⁄16˝ wide flat strapping.
• LSTI33⁄4˝ wide flat strapping for open web trusses.
• MSTC Series3˝ wide flat strapping.
• KHST Series Heavy-capacity bolted strap.
• KRPS SeriesProtection strap for pipes placed in partitions.
• PS SeriesPost to beam strap.
Pre-Bent Straps . . . . . . . . . . . . . . .Page 77• MSTC66B3 SeriesMedium-capacity nail-on floor tie strap.
Twist Straps . . . . . . . . . . . . . . .Pages 78-79• LFTA6Light-capacity twist strap.
• LTW SeriesLight-capacity twist strap.
• MTW SeriesMedium-capacity twist strap.
• HTW SeriesHeavy-capacity twist strap.
KRPS
PS
Angles & Straps
KST
KHST
MSTC
LSTI
KSTI
CMST/CMSTC RS
LSTA/MSTA
ST
MSTC66B3
continued on next page
USP2173-111
An
gle
s &
Stra
ps
1-800-328-5934 • www.USPconnectors.com 61
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Angles & Straps
1-800-328-5934 • www.USPconnectors.com
Masonry Straps . . . . . . . . . . .Pages 80-81• MSTAM Series1/4˝ wide flat strapping.
• MSTCM Series3˝ wide flat strapping.
• HTWM SeriesHeavy-capacity twist strap connects to concrete or masonry walls
Knee Braces & Connector Straps . . . . . . . . . . . . .Pages 81-82• KHSA & KSA Series Seismic horizontal tension tie.
• KVB & KVBI Series Knee brace for beam lateral stability.
Permanent Wood Foundation Strap . . . . . . . . . . . . . . . . . . . . . . . . .Page 83• PWFS24Transfers ground lateral loads to floor diaphragm.
PWFS24
KSA
HTWM
KVB
MSTAM MSTCM40
MP34 – Framing angle without tabs.
MPA1 – Tabs enable two and three-way connections.
MP4F – Connects 2x framing with floor sheathing up to 5/8˝.
MP6F – Connects 3x framing with floor sheathing up to 3/4˝. Better choicefor connections where floor sheathing is between sole plate and rim board.
Materials: See chartFinish: G90 galvanizing, MPA1-GC – Gold Coat.
Options: MPA1, MP34, & MP4F are available in Triple Zinc. To order, add TZ to stock number, as in MPA1-TZ. MPA1 & MP34 are available in Stainless Steel. To order, add SS to stock number, as in MPA1-SS.
Codes: ESR-1781, ESR-1881, FL821, FL570, FL13285, Dade County FL 07-0419.01 L.A. City RR 25779, L.A. City RR 25843
Installation:• Use all specified fasteners. See Product Notes, page 11.• Bend tabs only once.• MP4F connects 2x framing with floor sheathing up to 5⁄8˝.• MP6F connects 3x framing with floor sheathing up to 3⁄4˝. Better choice for connections where floor sheathing is between sole plate and rim board.
An
gle
s &
Str
ap
s
1-800-328-5934 • www.USPconnectors.com62
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Multi-Purpose Framing Angles – MP34, MPA1 & MPF series
1 1/2˝1 7/16˝
4 1/2˝
MP34
2 13/16˝
1 1/2˝1 7/16˝
Typical MPA1stud / plate installation
B2
A2
C2
B1
A1 C1
Typical MP34joist / header installation
F1
F3
F2
F3
F1
F3F3
F2
Typical MPA1joist / header installation
Typical MPA1rafter / plate installation
continued on next page
MPA1
Figure 1 Figure 2 Figure 3
Figure 4
USP2173-111
An
gle
s &
Stra
ps
1-800-328-5934 • www.USPconnectors.com 63
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
MP4F
MP4F
MP6F
Sheathing
Embossed plate lineguides placement
VH
Typical MP_F installation
Type 1
Type 2
Multi-Purpose Framing Angles – MP34, MPA1 & MPF cont.
Ref. No. Qty Type Qty Type 100% 115% 125% 160% 100% 115% 125% 160%
6 8d x 1-1/2 6 8d x 1-1/2 F1 570 655 680 680 490 565 570 5706 8d x 1-1/2 6 8d x 1-1/2 F2 570 655 715 795 490 565 615 670
6 8d x 1-1/2 6 8d x 1-1/2 F3 280 320 350 445 180 205 225 2906 8d x 1-1/2 3 8d x 1-1/2 A1 285 330 355 415 245 285 310 350
6 8d x 1-1/2 3 8d x 1-1/2 B1 285 330 350 350 245 285 295 295
6 8d x 1-1/2 3 8d x 1-1/2 C1 285 330 355 355 245 285 300 3006 8d x 1-1/2 6 8d x 1-1/2 A2 505 505 505 505 425 425 425 425
6 8d x 1-1/2 6 8d x 1-1/2 B2 280 280 280 280 235 235 235 2356 8d x 1-1/2 6 8d x 1-1/2 C2 375 375 375 375 315 315 315 315
6 N8-GC 6 N8-GC F1 570 655 680 680 490 565 570 570
6 N8-GC 6 N8-GC F2 570 655 715 795 490 565 615 6706 N8-GC 6 N8-GC F3 280 320 350 445 180 205 225 290
6 N8-GC 3 N8-GC A1 285 330 355 415 245 285 310 3506 N8-GC 3 N8-GC B1 285 330 350 350 245 285 295 295
6 N8-GC 3 N8-GC C1 285 330 355 355 245 285 300 300
6 N8-GC 6 N8-GC A2 505 505 505 505 425 425 425 4256 N8-GC 6 N8-GC B2 280 280 280 280 235 235 235 235
6 N8-GC 6 N8-GC C2 375 375 375 375 315 315 315 3154 8d x 1-1/2 4 8d x 1-1/2 F1 380 435 475 525 330 375 410 450
4 8d x 1-1/2 4 8d x 1-1/2 F2 380 435 475 610 330 375 410 5254 8d x 1-1/2 4 8d x 1-1/2 F3 185 215 230 295 120 140 150 190
6 8d x 1-1/2 6 8d x 1-1/2 V 565 650 705 845 485 560 610 710
6 8d x 1-1/2 6 8d x 1-1/2 H 565 650 705 845 485 560 610 7106 8d x 1-1/2 6 8d x 1-1/2 V 565 650 705 845 485 560 610 710
6 8d x 1-1/2 6 8d x 1-1/2 H 565 650 660 660 485 555 555 5556 8d 6 8d V 565 650 705 845 485 560 610 710
6 8d 6 8d H 565 650 705 845 485 560 610 710
6 8d 6 8d V 565 650 705 845 485 560 610 7106 8d 6 8d H 565 650 660 660 485 555 555 555
6 8d x 1-1/2 6 8d x 1-1/2 V 565 605 605 605 485 510 510 5106 8d x 1-1/2 6 8d x 1-1/2 H 565 605 605 605 485 510 510 510
6 8d x 1-1/2 6 8d x 1-1/2 V 565 605 605 605 485 510 510 510
6 8d x 1-1/2 6 8d x 1-1/2 H 565 605 605 605 485 510 510 5106 8d 6 8d V 565 605 605 605 485 510 510 510
6 8d 6 8d H 565 605 605 605 485 510 510 5106 8d 6 8d V 565 605 605 605 485 510 510 510
6 8d 6 8d H 565 605 605 605 485 510 510 510
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) Refer to drawings for installation type and definition of the various load directions. 3) 8d x 1-1/2 and N8-GC nails are 11 gauge (0.131˝ diameter) by 1-1/2˝ long. 4) If installing MP4F or MP6F over plywood, use 8d common nails for 100% of table load. 5) Loads are shown per angle. When using a single anchor, joist must be constrained from rotation. 6) Minimum nail embedment shall be 1-5/16˝ for 8d nails.
CodeRef.
5,F5,F30,D7
6,F15,R13
Fastener Schedule3,6 Allowable Loads (Lbs.)1,5
DF-L / SPSteelGauge
S-P-FDirection
of Load2USP
Stock No.
Installation
Type2,4
Joist or PlateHeader or Stud
MP34 A34 18 Figure 4
A35 MPA1
Figure 1
Figure 2
Figure 3
18
MP6F LTP5 20
MP4F LTP4 20
Type 1
Type 2
Type 1
Type 2
Type 1
Type 2
Type 1
Type 2
MPA1-GC -- -- 18
Figure 1
Figure 2
Figure 3
4 1/4˝
Embossed plate lines
MP4F = 1˝MP6F = 1 3/4˝
MP4F = 3˝MP6F = 3 3/4˝
MP_F
An
gle
s &
Str
ap
s
1-800-328-5934 • www.USPconnectors.com64
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Roof Boundary Clips – RBC
1-800-328-5934 • www.USPconnectors.com
Typical RBCTop-Plate to Outside of
Blocking installation
Typical RBCTop-Plate to Inside of Blocking installation
Framing plate designed to connectroof blocking to a wall top plate.
Materials: 20 gaugeFinish: G90 galvanizing
Installation:• Use all specified fasteners.SeeProduct Notes, page 11.• Field adjustable from 0º to 90º.• Bend angle only once.
RBC
H W
DF-L / SP S-P-F
Ref. No. W H Qty Type2 Qty Type2 160% 160%
RBC RBC 20 4-1/4 6 6 10d x 1-1/2 6 10d x 1-1/2 525 440 110
1) Allowable loads have been increased 160% for wind or seismic loads; no further increase shall be permitted. 1) Loads shown are for a single roof boundary clip. 2) 10d x 1-1/2 nails are 9 gauge (0.148" diameter) by 1-1/2" long. New products or updated product information are designated in bold font.
CodeRef.
Allowable Loads (Lbs.)
SteelGauge
Lateral
USPStock No.
Dimensions
Top Plate Blocking
Fastener Schedule2,3
Up to 3/4˝ gap
Up to 3/4˝ gap
Typical RBC1˝ foamboard installation
USP2173-111
An
gle
s &
Stra
ps
1-800-328-5934 • www.USPconnectors.com 65
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Framing Angles – A3, AC, JA, & MP series
W1W2
L
F1 F2
F3F3
L
W2W1
Typical ACinstallation
AC A3
Adjust0˚ to 135˚
Loaddirection
Typical MPinstallation
MP – Field adjustable from 0° to 135°.
A3 – 18 gauge. Eliminates toenailing and increases strength.
AC – 16 gauge. Features staggered nail patterns which reduceswood splitting and allows installation on both sides of the supported member.
Materials: See chartFinish: G90 galvanizing; AC7-GC, AC9-GC, MP7-GC, &
MP9-GC – Gold CoatOptions: MP5, MP7, MP9, A3, AC5, AC7, AC9, & JA1
are available Triple Zinc. To order, add TZ to stock number, as in MP5-TZ. MP7 is available in Stainless Steel. To order, add SS to stock number,as in MP7-SS.
Codes: ESR-1831, ESR-2104, ESR-1781,L.A. City RR 25745, L.A. City RR 25836, L.A. City RR 25843, FL820, FL822, FL13285, Dade County, FL 07-0419.01
Installation:• Use all specified fasteners. See Product Notes, page 11.• MP Framing Angles are fabricated at 100° and may be field adjusted by hand from 0° to 135°. Bend angle only once.
2 1/4˝ 2 1/4˝
L
Typical MPRafter Support
installation
MPTypical JA7installation
F2F1
F3F3
L
W1W2
JA3
Typical JA1installation
continued on next page
Ref. No. W1 W2 L Qty Type Qty Type 100% 115% 125% 160% 100% 115% 125% 160%
F1 450 515 560 590 390 445 485 495
F2 450 515 560 600 390 445 485 505
F3 210 240 260 335 135 155 170 215 MP3 LS30 18 2-1/4 2-1/4 3-3/8 3 10d 3 10d F1 340 395 430 485 295 340 370 470
MP5 LS50, S/LS50
18 2-1/4 2-1/4 4-5/8 4 10d 4 10d F1 455 525 570 730 390 450 490 625
MP7 LS70, S/LS70 5 10d 5 10d
MP7-GC -- -- 5 N10C-GC 5 N10C-GC
MP9 LS90 6 10d 6 10d MP9-GC -- -- 6 N10C-GC 6 N10C-GC
CodeRef.
8,F14,R9
10,F16,R14
Fastener Schedule2,4,5
10d x 1-1/2
DF-L / SP S-P-F
Dimensions
Header
A3 A23, GA1, GA2, L30, S/A23
18 1-7/16 1-7/16 2-3/4 4 10d x 1-1/2
Allowable Loads (Lbs.)1,3
Directionof Load
USPStock No.
JoistSteelGauge
4
18 2-1/4 2-1/4 5-7/8 F1 570 655 715 910 490 565 615 785
18 685 785 855 1095 590 675 735 940F16-7/82-1/4 2-1/4
An
gle
s &
Str
ap
s
1-800-328-5934 • www.USPconnectors.com66
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Ref. No. W1 W2 L Qty Type Qty Type 100% 115% 125% 160% 100% 115% 125% 160%
F1 340 390 425 540 290 335 365 465
F2 340 390 425 540 290 335 365 465F3 155 180 195 250 100 115 125 160
F1 380 440 475 610 325 375 410 520
F2 380 440 475 610 325 375 410 525F3 175 205 220 280 115 130 145 185
F1 450 520 565 725 390 445 485 620F2 450 520 565 725 390 445 485 620
F3 210 240 260 335 135 155 170 215F1 510 585 635 770 435 500 545 645
F2 510 585 635 815 435 500 545 700
F3 235 270 295 375 150 175 190 245F1 450 520 565 725 390 445 485 620
F2 450 520 565 725 390 445 485 620F3 210 240 260 335 135 155 170 215
F1 510 585 635 770 435 500 545 645
F2 510 585 635 815 435 500 545 700F3 235 270 295 375 150 175 190 245
F1 565 650 705 905 485 560 605 775F2 565 650 705 905 485 560 605 775
F3 260 300 325 415 170 195 210 270
F1 635 730 795 1015 545 625 680 870F2 635 730 795 920 545 625 680 775
F3 295 340 370 470 190 220 240 305F1 225 255 255 255 190 215 215 215
F2 -- -- -- -- -- -- 345 -- -- -- -- -- -- 290
F3 -- -- -- -- -- -- 165 -- -- -- -- -- -- 140F1 455 525 570 590 380 440 480 495
F2 -- -- -- -- -- -- 535 -- -- -- -- -- -- 450F3 -- -- -- -- -- -- 330 -- -- -- -- -- -- 275
F1 685 785 855 950 575 660 720 800
F2 -- -- -- -- -- -- 1015 -- -- -- -- -- -- 855F3 -- -- -- -- -- -- 495 -- -- -- -- -- -- 415
F1 910 1050 1140 1460 765 880 960 1225F2 -- -- -- -- -- -- 1625 -- -- -- -- -- -- 1365
F3 -- -- -- -- -- -- 550 -- -- -- -- -- -- 460F1 1140 1310 1425 1825 960 1100 1195 1535
F2 -- -- -- -- -- -- 1645 -- -- -- -- -- -- 1380
F3 -- -- -- -- -- -- 825 -- -- -- -- -- -- 695
1) Allowable loads have been increased 60% for wind and seismic loads; no further increase shall be permitted. 2) Minimum nail embedment shall be 1-1/2˝ for 10d and N10C-GC nails; 1-5/8˝ for 16d and N16C-GC nails. 3) Loads are shown per angle, and may be doubled if installed in pairs. When using a single angle, joist must be constrained from rotation. 4) For 1-1/2˝ lumber, use 0.98 of table load for 10d nails and 0.92 for 16d nails. 5) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long.
5,F30,R5
CodeRef.
8,F14,R9
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
10d
16d
16d
10d
16d
10d
16d
16d
10d
16d
N10C-GC
N16C-GC
10d x 1-1/2
16d 4
2-3/8 8-7/8
5 5
5 5
2-3/8 6-15/16
AC9 L90 16 1-5/16
4 4
4 4
10d
16d
AC7 L70 16 1-5/16
2-3/8 4-7/8
3 3
3 3
10d
16d
AC5 L50 16 1-5/16
JA1 A21 16 1-1/4 2 21-1/2
JA3 -- -- 14 2-1/2 2-1/2 4
1-1/2
6 62-1/2 2-1/2 5 16d
3
JA7 -- -- 14 72-1/2 2-1/2
JA5 -- -- 14
8 8
JA9 -- -- 14 9 10 102-1/2 2-1/2
AC7-GC -- -- 16 1-5/16
4 4
4 4
N10C-GC
N16C-GC
USPStock No.
SteelGauge
Header Joist
5,F30,D7,R5
5,F30,R5
Dimensions Fastener Schedule2,4,5 Allowable Loads (Lbs.) 1,3
Directionof Load
DF-L / SP S-P-F
2-3/8 6-15/16
Framing Angles – A3, AC, JA, & MP series cont.
USP2173-111
An
gle
s &
Stra
ps
1-800-328-5934 • www.USPconnectors.com 67
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
W
H
1 1/4˝
W
H
1 1/4˝
H
L
W
SPT22 SPT
SPTH
Typical SPT4 installation
Stud Plate Ties – RSPT, SPT, & SPTH series
RSPT – 18 or 20 gauge. Connects stud to single or double plates.
SPT – 20 gauge. Ties single and double plates to studs.
SPTH – Heavier 18 gauge version of SPT.
SPTHW – 18 gauge. Attaches plate to studs over 1/2˝ sheathing.
Materials: See chartFinish: G90 galvanizing
Options: SPT4, SPT6, SPT22, SPT24, SPTH4, & SPTH6are available in Triple Zinc. To order, add TZ to stock number, as in SPTH4-TZ.
Codes: ESR-1881, ESR-1465, FL817, FL821L.A. City RR 25779
Installation:• Use all specified fasteners. See Product Notes, page 11.
Nailing concentrated ontop plate for greater
resistanceF2
F1
Uplift
Typical RSPT4 doubleplate installation
Typical RSPT4 singleplate installation
Locator tabReinforcement
ribs
1 1/2˝
4 1/8˝
RSPT4 SPTHW1 1/4˝
W
H
F1 F2 Uplift1
Ref. No. W H L Qty Type Qty Type 160% 160% 160%
2x SPT22 SP1 20 1-9/16 4-3/8 3-1/2 4 10d 4 10d 560 260 685
2x SPT24 SP2 20 1-9/16 5-5/8 3-1/2 6 10d 6 10d 560 260 1030 4x SPT44 -- -- 20 3-9/16 6-3/4 6-1/2 6 16d 6 16d 680 255 1305
2x RSPT4 RSP4 20 1-1/2 4-1/8 -- -- 4 8d x 1-1/2 4 8d x 1-1/2 230 300 470
2x RSPT6 SSP 18 1-1/2 5-7/16 -- -- 4 10d x 1-1/2 4 10d x 1-1/2 -- -- -- -- 700 (2) 2x RSPT6-2 DSP 18 2-3/4 5-7/16 -- -- 8 10d x 1-1/2 6 10d x 1-1/2 -- -- -- -- 955
4x SPT4 SP4 20 3-9/16 6-7/8 -- -- 6 10d x 1-1/2 -- -- -- -- -- -- -- -- 945 6x SPT6 SP6 20 5-9/16 7-5/8 -- -- 6 10d x 1-1/2 -- -- -- -- -- -- -- -- 945
8x SPT8 SP8 20 7-5/16 8-1/2 -- -- 6 10d x 1-1/2 -- -- -- -- -- -- -- -- 945
SPTH4 SPH4 18 3-9/16 8-5/8 -- -- 12 10d x 1-1/2 -- -- -- -- -- -- -- -- 1730 SPTHW4 SPH4R 18 4-1/16 8-3/8 -- -- 12 10d x 1-1/2 -- -- -- -- -- -- -- -- 1290
SPTH6 SPH6 18 5-9/16 9-3/8 -- -- 12 10d x 1-1/2 -- -- -- -- -- -- -- -- 1730 SPTHW6 SPH6R 18 6-1/16 9-1/8 -- -- 12 10d x 1-1/2 -- -- -- -- -- -- -- -- 1290
8x SPTH8 SPH8 18 7-5/16 8-1/2 -- -- 12 10d x 1-1/2 -- -- -- -- -- -- -- -- 1730
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 3) 8d x 1-1/2 nails are 11 gauge (0.131˝ diameter) by 1-1/2˝ long. 4) Minimum nail embedment shall be 1-1/2˝ for 10d nails and 1-5/8˝ for 16d nails. 5) SPT22, SPT24, and SPT44: the two nails fastened to the wide face of the stud must be driven 30° from the perpendicular on the horizontal plane.
11,F12
6,F15,R13
Dimensions Fastener Schedule2,3,4
Stud
CodeRef.
Allowable Loads (Lbs.)
DF-L / SP
4x
Plate
6x
StudSize
USP
Stock No.5Steel
Gauge
F2
F1Uplift
Typical SPT24installation
5 7/16˝
2 3/4˝
5 7/16˝
1 1/2˝
RSPT6
RSPT6-2
An
gle
s &
Str
ap
s
1-800-328-5934 • www.USPconnectors.com68
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®The LJC-TZ and LJQ-TZ Lateral Joist Connectors transfer lateral loads at thetop foundation to the floor joists. The fastening patterns meet I-joist manufacturer recommendations.
LJC-TZ – fastens the top side of the sill plate to the underside of the floorjoist preventing splitting of the bottom chord flanges, and can be installedafter the floor system has been installed. The product is load rated for usewith dimension lumber floor joists as well as I-joist. It can also be used withcantilevered floor joists.
LJQ-TZ – is a higher capacity connector designed for higher loads. It is similar in design to a joist hanger with a seat for the floor joist to bear againstand utilizes wood screws to fasten to the sill plate. USP’s WS15-GC WoodScrews (included) provide quick installation without the need to pre-drillholes.
Materials: See chartFinish: G-185 galvanizing
Installation:• Use all specified fasteners. See Product Notes, page 11.• LJC-TZ – Installs after the floor joist has been placed with a minimum of(12) 8d x 1-1/2˝ HDG nails.• LJQ-TZ – Installs with (4) USP WS15-GC Wood Screws. WS15-GC WoodScrews are 1/4˝ diameter x 1-1/2˝ long and are included with LJQ-TZ connectors.
Typical LJC-TZ installation
W
L1/2̋
W
D
L
LJC-TZ
Typical LJQ-TZ installation
LJQ-TZ
2x I-Joist
Ref. No. W L D Qty Type 100% 100%
LJC-TZ -- -- 18 3-3/16 8 -- -- 12 8d x 1-1/2 445 515
LJQ15-TZ -- -- 16 1-9/16 3 1-1/2 4 WS15-GC 905 1145
LJQ17-TZ -- -- 16 1-13/16 3 1-1/2 4 WS15-GC 905 1145 LJQ20-TZ -- -- 16 2-1/8 3 1-1/2 4 WS15-GC 905 1145
LJQ23-TZ -- -- 16 2-5/16 3 1-1/2 4 WS15-GC 905 1145 LJQ25-TZ -- -- 16 2-9/16 3 1-1/2 4 WS15-GC 905 1145
LJQ35-TZ -- -- 16 3-9/16 3 1-1/2 4 WS15-GC 905 1145
1) WS15-GC wood screws are 1/4˝ x 1/2˝ and are included with LJQ-TZ connector. 2) 8d x 1-1/2 nails are 11 gauge (0.131˝ diameter) by 1-1/2˝ long. 3) Allowable loads are based on 2x6 SP sill plate. For 2x4 sill plate applications, reduce the value of the LJC-TZ by 45 percent.
110
CodeRef.
USPStock No.
SteelGauge
Dimensions (inches) Allowable Loads (Lbs.)3
SP
FastenerSchedule 1,2
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Header Hangers support headers in door and window framing. Helps to eliminatecracks in drywall, plaster, or stucco over windows and doors. These products alsoprovide anchorage and support for heavy fence rails, struts, or gate post crossbrackets.
Materials: 16 gaugeFinish: G90 galvanizingCodes: ESR-1280, FL11664, L.A. City RR 25749
Installation:• Use all specified fasteners. See Product Notes, page 11.
2˝
H
W
3 3/4˝
HH44
F3
F1
F2
F4
Typical HH44installation
Lateral Joist Connectors – LJC-TZ & LJQ-TZ series
Header Hangers – HH series
F21 F31 F41
Ref. No. W H Qty Nail Qty Nail 100% 115% 125% 160% 160% 160%
HH44 HH4 16 3-9/16 3-1/4 4 16d 9 16d 1240 1430 1500 885 685 1100 HH66 HH6 16 5-1/2 5-1/4 6 16d 12 16d 1655 1905 2070 1150 1325 1100
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) Minimum nail embedment shall be 1-5/8˝ for 16d nails.
CodeRef.
2, F20, R12
USPStock No.
SteelGauge
Dimensions
F1
DF-L / SP
Allowable Loads (Lbs.)
Header Stud
Fastener Schedule2
USP2173-111
An
gle
s &
Stra
ps
1-800-328-5934 • www.USPconnectors.com 69
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Heavy Angles – KHL series
1-800-328-5934 • www.USPconnectors.com
Heavy Angles – ANJ44S-HDG
Ref. No. W H L Qty Lag Screw Qty Lag Screw 100% 115% 125%
ANJ44S-HDG -- -- 7 3-1/2 4 4 2 1/2˝ 2 1/2˝ 510 585 640 130
1) Loads based on use of (2) 1/2˝ x 2˝ lag screws, loaded parallel to grain, in Douglas Fir-Larch (G=.50).
CodeRef.
Dimensions Allowable Loads (Lbs.)
USPStock No.
SteelGauge
DF-L / SPHeader Joist
Fastener Schedule1
ANJ44S-HDG
Materials: 7 gaugeFinish: Hot-dip galvanized
Installation:• Install with (2) 1/2˝ x 2˝ lag screws into each leg.
Typical ANJ44S-HDGinstallation
Ref. No. W L D1 D2 D3 D4 Qty Dia.
KHL33 HL33 7 3-1/4 2-1/2 1-1/4 -- -- 2 -- -- 2 5/8 KHL35 HL35 7 3-1/4 5 1-1/4 2-1/2 2 -- -- 4 5/8
KHL37 HL37 7 3-1/4 7-1/2 1-1/4 2-1/2 2 -- -- 6 5/8 KHL43 HL43 3 4-1/4 3 1-1/2 -- -- 2-3/4 -- -- 2 3/4
KHL46 HL46 3 4-1/4 6 1-1/2 3 2-3/4 -- -- 4 3/4
KHL49 HL49 3 4-1/4 9 1-1/2 3 2-3/4 -- -- 6 3/4 KHL53 HL53 7 5-3/4 2-1/2 1-1/4 -- -- 2 2-1/2 4 5/8
KHL55 HL55 7 5-3/4 5 1-1/4 2-1/2 2 2-1/2 8 5/8 KHL57 HL57 7 5-3/4 7-1/2 1-1/4 2-1/2 2 2-1/2 12 5/8
KHL73 HL73 3 7-1/4 3 1-1/2 -- -- 2-3/4 3 4 3/4
KHL76 HL76 3 7-1/4 6 1-1/2 3 2-3/4 3 8 3/4 KHL79 HL79 3 7-1/4 9 1-1/2 3 2-3/4 3 12 3/4
1) All bolts shall meet or exceed the specifications of ASTM A 307.
CodeRef.
120
USPStock No.
SteelGauge
Dimensions Fastener Schedule
Bolts1
KHL55
D4
D2 D1
D3
W
W
L
KHL33
Designed for heavy-duty reinforcement of 90° framing intersections.
Materials: See chartFinish: USP primer
Options: KHL35 and KHL43 are available in Hot-dip galvanized. To order add HDG to stock number as in KHL35-HDG
Installation:• Use all specified fasteners. See Product Notes, page 11.• Design loads shall be determined for each installation by a qualified designer.• Design loads based on member species, size, and direction of grain.
Typical KHL35installation
4˝3 1/2˝
4˝
Materials: 14 gaugeFinish: G90 galvanizing
Options: L6 and T6 are available in Triple Zinc. To order, addTZ to stock number, as in L6-TZ.
Installation:• Use all specified fasteners. See Product Notes, page 11.• Straps are not load rated.
An
gle
s &
Str
ap
s
1-800-328-5934 • www.USPconnectors.com70
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
H W
L
L6
H
LW
T6
Ref. No. W H L Qty Dia. Qty Type
T6 66T 14 1-1/2 5 6 3 1/2 12 16d T8 -- -- 14 2 8 8-1/2 3 1/2 12 16d
T12 128T 14 2 8 12 3 1/2 12 16d
L6 66L 14 1-1/2 6 6 2 1/2 8 16d L8 88L 14 2 8 8 2 1/2 8 16d
L12 1212L 14 2 12 12 4 1/2 12 16d
1) Minimum nail embedment is 1-5/8˝ for 16d nails. 2) All bolts shall meet or exceed the specifications of ASTM A 307.
Nails
Fastener Schedule1,2
CodeRef.
120
Dimensions
USPStock No.
SteelGauge
Bolts
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
L
W
L
Corner Brace – B & BL series
These multi-purpose braces are designed toprovide reinforcement for 90° wood-to-woodconnections.
Materials: 12 gaugeFinish: G90 galvanizing
Installation:• Use all specified fasteners. See ProductNotes, page 11.
L
W
L
BL4 B23
Ref. No. W L Qty Type Qty Type
B23 -- -- 12 2 2-5/8 6 16d -- -- -- --
B24 -- -- 12 2 3-5/8 8 16d -- -- -- --
BL3 A33 12 1-1/4 3-1/16 8 16d -- -- -- -- BL4 A44 12 1-1/4 4-13/16 10 16d -- -- -- --
BL6 -- -- 12 1-1/4 6-9/16 12 16d -- -- -- -- BL8 -- -- 12 1-1/4 8-5/16 14 16d -- -- -- --
B66 A66 12 1-1/2 6 -- -- -- -- 4 3/8 B88 A88 12 2 8 -- -- -- -- 6 3/8
1) Minimum nail embedment shall be 1-5/8˝ for 16d nails. 2) Bolts shall conform to ASTM A 307 or better.
Dimensions
USPStock No.
SteelGauge
Nails1CodeRef.
120
Bolts 2
Fastener Schedule
B66 Typical B66installation
Some model designs may varyfrom illustration shown
L & T Straps – L & T series
USP2173-111
An
gle
s &
Stra
ps
1-800-328-5934 • www.USPconnectors.com 71
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
2 1/2˝
3 1/4˝
3 1/4˝
Ref. No. Description W H L Qty Dia.
KHL33-O OHA33 7 Heavy Angle 3-1/4 -- -- 2-1/2 2 5/8
KHL36-O OHA36 7 Heavy Angle 3-1/4 -- -- 6 4 5/8 KHST64-O OHS135 7 Strap Tie 6 -- -- 13-1/2 4 3/4
ST12-O OS 12 Strap Tie 2 -- -- 12 4 1/2 L12-O OL 12 'L' Strap 2-1/2 11-7/8 11-7/8 5 1/2
LH12-O OHL 7 'L' Strap 2-1/2 11-7/8 11-7/8 5 5/8
T1212-O OT 12 'T' Strap 2-1/2 11-7/8 14-1/2 6 1/2 TH12-O OHT 7 'T' Strap 2-1/2 11-7/8 11-1/8 4 5/8
TH16-O -- -- 7 'T' Strap 2-1/2 11-7/8 16-1/8 6 5/8
1) All bolts shall meet or exceed the specifications of ASTM A 307.
Bolt Schedule1CodeRef.
120
USPStock No.
SteelGauge
Dimensions
H W
L
L
KHL33-O
Ornamental series
Ornamental notching provides architectural appearance forexposed applications.
Materials: See chartFinish: USP primer
Installation:• Use all specified fasteners. See Product Notes, page 11.
Ornamental series
Some modeldesigns may
vary fromillustration
shown
H
L
W
T
An
gle
s &
Str
ap
s
1-800-328-5934 • www.USPconnectors.com72
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Coiled Strapping – CMST series, CMSTC16, & RS series
Ref. No. Cut Length Min Qty.2 Nails Cut Length Min Qty.2 Nails 160%
16 54' Clear Span + 46˝ 23˝ 60 10d Clear Span + 58˝ 29" 74 10d 1-1/2˝
16 54' Clear Span + 90˝ 45˝ 60 10d Clear Span + 112˝ 56" 74 10d 3˝16 54' Clear Span + 40˝ 20" 50 16d Clear Span + 48˝ 24" 62 16d 1-1/2˝
16 54' Clear Span + 76˝ 38" 50 16d Clear Span + 94˝ 47" 62 16d 3˝
14 52-1/2' Clear Span + 58˝ 29˝ 64 16d Clear Span + 72˝ 36" 80 16d 1-3/4˝14 52-1/2' Clear Span + 130˝ 65˝ 74 10d Clear Span + 164˝ 82" 94 10d 3-1/2˝
14 52-1/2' Clear Span + 256˝ 128˝ 74 10d Clear Span + 326˝ 163" 94 10d 7˝12 40' Clear Span + 74˝ 37˝ 82 16d Clear Span + 90˝ 45" 102 16d 1-3/4˝
12 40' Clear Span + 168˝ 84˝ 96 10d Clear Span + 206˝ 103" 118 10d 3-1/2˝
12 40' Clear Span + 332˝ 166˝ 96 10d Clear Span + 410˝ 205" 118 10d 7˝22 300' Clear Span + 12˝ 6˝ 12 10d Clear Span + 14˝ 7" 16 10d 1-1/2˝
22 300' Clear Span + 12˝ 6˝ 14 8d Clear Span + 16˝ 8" 18 8d 1-1/2˝20 250' Clear Span + 12˝ 6˝ 14 10d Clear Span + 16˝ 8" 18 10d 1-1/2˝
20 250' Clear Span + 14˝ 7˝ 16 8d Clear Span + 18˝ 9" 20 8d 1-1/2˝
18 200' Clear Span + 16˝ 8˝ 18 10d Clear Span + 18˝ 9" 22 10d 1-1/2˝18 200' Clear Span + 18˝ 9˝ 22 8d Clear Span + 22˝ 11" 26 8d 1-1/2˝
18 100' Clear Span + 16˝ 8˝ 18 10d Clear Span + 18˝ 9" 22 10d 1-1/2˝18 100' Clear Span + 18˝ 9˝ 22 8d Clear Span + 22˝ 11" 26 8d 1-1/2˝
16 150' Clear Span + 18˝ 9˝ 22 10d Clear Span + 24˝ 12" 28 10d 1-1/2˝16 150' Clear Span + 22˝ 11˝ 26 8d Clear Span + 26˝ 13" 32 8d 1-1/2˝
14 100' Clear Span + 24" 12" 28 10d Clear Span + 30" 15" 36 10d 1-1/2˝
14 100' Clear Span + 28" 14" 34 8d Clear Span + 34" 17" 42 8d 1-1/2˝22 25' Clear Span + 12˝ 6˝ 12 10d Clear Span + 14˝ 7" 16 10d 1-1/2˝
22 25' Clear Span + 12˝ 6˝ 14 8d Clear Span + 16˝ 8" 18 8d 1-1/2˝20 25' Clear Span + 12˝ 6˝ 14 10d Clear Span + 16˝ 8" 18 10d 1-1/2˝
20 25' Clear Span + 14˝ 7˝ 16 8d Clear Span + 18˝ 9" 20 8d 1-1/2˝
18 25' Clear Span + 16˝ 8˝ 18 10d Clear Span + 18˝ 9" 22 10d 1-1/2˝18 25' Clear Span + 18˝ 9˝ 22 8d Clear Span + 22˝ 11" 26 8d 1-1/2˝
16 25' Clear Span + 18˝ 9˝ 22 10d Clear Span + 24˝ 12" 28 10d 1-1/2˝16 25' Clear Span + 22˝ 11˝ 26 8d Clear Span + 26˝ 13" 32 8d 1-1/2˝
14 25' Clear Span + 24" 12" 28 10d Clear Span + 30" 15" 36 10d 1-1/2˝
14 25' Clear Span + 28" 14" 34 8d Clear Span + 34" 17" 42 8d 1-1/2˝
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) Minimum quantity of fasteners to be installed with equal fasteners at each end of the connection. Product may have additional nail holes not needed to meet published allowable load of product. 3) 16d sinker nails may be substituted for 10d nails with no load reduction. 4) Minimum nail embedment shall be 1-5/16˝ for 8d nails, 1-1/2˝ for 10d nails, and 1-5/8˝ for 16d nails. New products or updated product information are designated in bold font.
6,F15,R13
1730
925
2610
6630
9320
1045
1375
10,F16,R14
2610
CMST14 CMST14
CoilLength
Rim Joist Installation
CMSTC16
EndLength
SteelGauge
CMSTC16
USPStock No.
RS300 CS22
CMST12 CMST12
RS100 CS18S
RS250 CS20
CS18 RS200
RS22-R CS22-R
RS150 CS16
RS14-100 CS14
RS14-R CS14-R
RS20-R CS20-R
RS16-R CS16-R
RS18-R CS18-R
1730
1375
AllowableTension
(Lbs.)1
4715
1375
925
1045
11,F12
CodeRef.
DF-L / SP
FastenerSchedule 3,4
S-P-F / Hem Fir
FastenerSchedule3,4
Rim Joist Installation
EndLength
NailSpacing
O.C.
2 1/4˝
1 1/2˝
3˝ Typ.
3˝
3/4˝
CMSTC16
1 1/2˝
1 1/4˝1/2˝
3/8˝
3/4˝
RS
CMST
1 1/2˝
1 3/4˝
3˝
1˝
3 1/2˝
CutLength
1˝ Min.
EndLength
ClearSpan
EndLength
Optional nails(wood shrinkage mayoccur and cause strapto buckle outward)
Typical RSrim joist installation
CMST similar
Coiled strapping enables cut-to-length convenience for avariety of immediate job site needs.
CMST – 3˝ wide strapping features diamond nail holes toprovide nailing options and reduce wood splitting.
CMSTC – 3˝ wide strapping is designed for high load conditions. Engineered to reduce wood splitting.
RS – 11⁄4˝ wide strapping packaged in cartons containing 25-foot or longer coils.
Materials: See chartFinish: G90 galvanizing
Options: RS150 available in Triple Zinc. To order add TZ to stock number as in RS150-TZ.
Codes: ESR-1881, ESR-1465, ESR-1831,FL817, FL821, FL822,L.A. City RR 25779, L.A. City RR 25836
Installation:• Use all specified fasteners. See Product Notes, page 11. • For safety, always wear gloves when handling or cuttingcoiled strapping. • CMST installations: Install to a minimum 2 ply 2x edge.Increase nail spacing if wood begins to split.• Designer may specify alternate nailing schedules. Refer toNail Specification table on page 15 for nail shear values. Loadvalues shall not exceed published allowable loads.
USP2173-111
An
gle
s &
Stra
ps
1-800-328-5934 • www.USPconnectors.com 73
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Strap Ties – KST, KSTI, LSTA, LSTI, MSTA, MSTC & ST series
LSTA
/MST
A 9
˝LS
TA/M
STA
12˝
LSTA
/MST
A 15
˝LS
TA/M
STA
18˝
LSTA
/MST
A 2
1˝LS
TA/M
STA
24˝
LSTA
/MST
A 3
0˝
LSTA
/MST
A 3
6˝
1 1/4˝
LSTA/MSTA LSTI
LSTI
49 4
9˝LS
TI73
73˝
1 1/2˝
3/8˝typ.
3 3/4˝
3˝
KST scallopeddesign
KST2
9 9
7 /16
˝KS
T213
12 11
/ 16˝
KST2
16 15
15/ 16
˝KS
T218
19 3
/ 16˝
KST2
24 2
2 7 /
16˝
KST2
34 3
2 3 /
16˝
1 3/4˝
1 1/2˝
16 5/16˝
3/4˝
KST116
LSTA – 20 or 18 gauge, light-capacity 11/4˝ wide strapping.
LSTI – 33/4˝ wide strap ties provide tension load path for truss top chords. The nail pattern accommodates open web trusses with double top chord.
MSTA – 18 or 16 gauge, medium-capacity 11/4˝ wide strapping.
ST – 16 gauge, medium-capacity 11/4˝ wide strapping.
MSTC – 3˝ wide strapping. Slotted hole design allows for higher load capacities andreduce splitting of lumber when attached to multiple 2x members.
KST – 21/16˝ wide strapping. Straps can be fastened using either nails or bolts. SomeKST straps install only with nails.
KSTI – 21/16˝ wide strapping. Straps are designed for installation to wood I-Joist flanges.
continued on next page
ST
ST9
9 ˝
ST12
11 5
/ 8˝
ST18
17
3 /4˝
ST12
2 2
1 5/ 8
˝
1 1/4˝
KSTI
2 1/16˝
KSTI
226
26
˝KS
TI23
6 3
6˝
KSTI
248
48
˝KS
TI26
0 6
0˝
KSTI
272
72˝
MST
C28
28
1 /4˝
MST
C40
40 1 /
4˝M
STC5
2 52
1 /4˝
MST
C66
65
3 /4˝
MST
C78
77
3 /4˝
1 1/2˝
3˝
3˝
MSTC
KST2
27 2
7˝KS
T237
37
1 / 2˝
KST2
48 4
8˝
KST2
60
60
˝KS
T272
72˝
2 1/16˝
1 1/2˝
1 1/2˝
4 1/2˝
KSTstraight edge
design
Some model designs may varyfrom illustration shown
An
gle
s &
Str
ap
s
1-800-328-5934 • www.USPconnectors.com74
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Strap Ties – KST, KSTI, LSTA, LSTI, MSTA, MSTC & ST series cont.
Typical LSTIopen web truss
installation
continued on next page
LTW Twist strappages 79-80
Typical LSTA/MSTAI-Joist on Ridge Beam
installation
Materials: See chartFinish: G90 galvanizing
Options: MSTA9, MSTA12, MSTA15, MSTA18, MSTA21, MSTA24, MSTA30, & MSTA36 are available in Triple Zinc. To order, add TZ to stock number, as in MSTA9-TZ. MSTA12, MSTA18, MSTA24 & MSTA36 are available in Stainless Steel. To order, add SS to stock number, as in MSTA36-SS.
Codes: ESR-1781, ESR-1465, ESR-1831, FL11664, FL822, FL817, FL13825,L.A. City RR 25749, L.A. City RR 25843, L.A. City RR 25836
Installation:• Use all specified fasteners. See Product Notes, page 11.• Designer may specify alternate nailing schedules. Refer to Nail Specification table onpage 15 for nail shear values. Load values shall not exceed published allowable loads.The quantity of nails installed shall be equally distributed to both ends of the strap.• The quantity of nails installed shall be equally distributed to both ends of the strap.
Min DF-L / SP S-P-F / Hem Fir
Ref. No. W L Qty5 Type 160% 160%
KST116 ST2115 20 3/4 16-5/16 10 8 16d 665 665 10, F16, R14 LSTA9 LSTA9 20 1-1/4 9 8 8 10d 740 635 LSTA12 LSTA12 20 1-1/4 12 10 10 10d 930 790 LSTA15 LSTA15 20 1-1/4 15 12 12 10d 1115 950 LSTA18 LSTA18 20 1-1/4 18 14 14 10d 1235 1110 LSTA21 LSTA21 20 1-1/4 21 16 16 10d 1235 1235 LSTA24 LSTA24 20 1-1/4 24 18 16 10d 1235 1235 KST29 ST292 20 1-3/4 9-7/16 14 14 16d 1680 1320 KST213 ST2122 20 1-3/4 12-11/16 18 18 16d 1785 1700 KST216 ST2215 20 1-3/4 15-15/16 22 18 16d 1785 1700 LSTA30 LSTA30 18 1-1/4 30 22 22 10d 1640 1640 LSTA36 LSTA36 18 1-1/4 36 26 22 10d 1640 1640 MSTA9 MSTA9 18 1-1/4 9 8 8 10d 750 645 MSTA12 MSTA12 18 1-1/4 12 10 10 10d 935 810 MSTA15 MSTA15 18 1-1/4 15 12 12 10d 1125 970 MSTA18 MSTA18 18 1-1/4 18 14 14 10d 1310 1130 MSTA21 MSTA21 18 1-1/4 21 16 16 10d 1500 1295 MSTA24 MSTA24 18 1-1/4 24 18 18 10d 1640 1455 LSTI49 LSTI49 18 3-3/4 49 32 32 10d x 1-1/2 3150 2510 LSTI73 LSTI73 18 3-3/4 73 48 48 10d x 1-1/2 4130 3765 ST9 ST9 16 1-1/4 9 8 8 16d 885 760 ST12 ST12 16 1-1/4 11-5/8 10 10 16d 1105 950 ST18 ST18 16 1-1/4 17-3/4 14 14 16d 1395 1335 ST22 ST22 16 1-1/4 21-5/8 18 18 16d 1395 1395 MSTA30 MSTA30 16 1-1/4 30 22 22 10d 2065 1815 MSTA36 MSTA36 16 1-1/4 36 26 26 10d 2065 2065 MSTA48 MSTA49 16 1-1/4 48 32 26 10d 2045 2045 KST218 ST6215 16 1-3/4 19-3/16 26 26 16d 2960 2540 KST224 ST6224 16 1-3/4 22-7/16 30 30 16d 2960 2930
36 36 10d 3455 296536 34 16d 3860 332052 52 10d 4715 428552 46 16d 4715 449070 60 10d 4715 471570 52 16d 4715 4715
KST234 ST6236 14 1-3/4 32-3/16 42 36 16d 3775 3660 10, F16, R1488 72 10d 6015 601588 62 16d 6015 6015104 76 10d 6015 6015104 66 16d 6015 6015
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) Minimum nail embedment shall be 1-1/2˝ for 10d nails and 1-5/8˝ for 16d nails. 3) Total number of nail and/or bolt holes provided in the strap. 4) Minimum quantity of fasteners to be installed with equal fasteners at each end of the connection. Product may have additional nail holes not needed to meet published allowable load of product. 5) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 6) Allowable bolt loads are based on parallel-to-grain loading, minimum of 2-1/2˝ thick. 7) For MSTC straps: 16d sinker nails may be substituted for 10d nails with no reduction in load. New products or updated product information are designated in bold font.
28-1/4
USP
Stock No.8
SteelGauge
MSTC28 MSTC28 16 3
40-1/4
MSTC52 MSTC52 16 3 52-1/4
MSTC40 MSTC40 16 3
65-3/4
MSTC78 MSTC78 14 3 77-3/4
MSTC66 MSTC66 14 3
Uplift
CodeRef.
Dimensions
Total
Qty4
Allowable Loads (Lbs.) 1,2Fastener Schedule3,6
Nails
5,F30,R5
10,F16,R14
5,F30,R5
10,F16,R14
5,F30,R5
10, F16,R14
11,F12
11,F12
USP2173-111
An
gle
s &
Stra
ps
1-800-328-5934 • www.USPconnectors.com 75
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Strap Ties – KST, KSTI, LSTA, LSTI, MSTA, MSTC & ST series cont.
Total4 DF-L / SP Total
4 DF-L / SP Total4 DF-L / SP
Ref. No. Qty Uplift 160%1 Qty Uplift 160%1 Qty Uplift 160%1
18 -- -- -- -- 12 1150 12 136516 -- -- -- -- 16 1535 14 1590
18 -- -- -- -- 28 2690 24 272516 -- -- -- -- 32 3070 30 3410
18 -- -- -- -- 44 4225 38 4315
16 -- -- -- -- 48 4610 42 471518 -- -- -- -- 62 6015 54 6015
16 -- -- -- -- 64 6015 54 6015
18 -- -- -- -- 64 6015 54 601516 -- -- -- -- 66 6015 56 6015
18 -- -- -- -- -- -- -- -- 20 248016 -- -- -- -- -- -- -- -- 22 2730
18 -- -- -- -- -- -- -- -- 32 3970
16 -- -- -- -- -- -- -- -- 34 421518 -- -- -- -- -- -- -- -- 46 6255
16 -- -- -- -- -- -- -- -- 48 653018 -- -- -- -- -- -- -- -- 46 6255
16 -- -- -- -- -- -- -- -- 48 6530
18 14 1410 -- -- -- -- -- -- -- --16 16 1615 -- -- -- -- -- -- -- --
18 26 2620 -- -- -- -- -- -- -- --16 28 2820 -- -- -- -- -- -- -- --
18 38 3830 -- -- -- -- -- -- -- --
16 40 4030 -- -- -- -- -- -- -- --18 50 5040 -- -- -- -- -- -- -- --
16 52 5240 -- -- -- -- -- -- -- --
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) Minimum nail embedment shall be 1-1/2˝ for 10d nails and 1-5/8˝ for 16d nails. 3) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 4) Total number of of nail holes provided in the strap.
16d Fasteners210d x 1-1/2" Fasteners3
KST237
KST248
MST37, S/MST37
MST48, S/MST48
MSTC78 MSTC78
MSTC52
MSTC66
KSTI248 MSTI48
KST260
KST272
MST60, S/MST60
MST72, S/MST72
MSTC40
MSTC52
MSTC66
KSTI236 MSTI36
KSTI272 MSTI72
10d Fasteners2
USPStock No.
ClearSpan
MSTC28 MSTC28
KSTI260 MSTI60
MSTC40
End length
End length
Clear span
1˝ Min.
Optional nails(wood shrinkage may
occur and cause strapto buckle outward)
Typical KST237 floor-to-floorinstallation
Clear Span Chart
Min Min Nails Bolts8Nails Bolts8
Ref. No. W L Qty5 Type Qty5 Dia. 160% 160% 160% 160%
KST227 MST27, S/MST27 12 2-1/16 27 34 34 16d 4 1/2 4540 2285 3645 2020 KST237 MST37, S/MST37 12 2-1/16 37-1/2 48 48 16d 6 1/2 5140 3240 5140 2875 KST248 MST48, S/MST48 12 2-1/16 48 62 54 16d 8 1/2 5140 3845 5140 3555 KSTI226 MSTI26 12 2-1/16 26 26 26 10d x 1-1/2 -- -- -- -- 2810 -- -- 2245 -- -- KSTI236 MSTI36 12 2-1/16 36 36 36 10d x 1-1/2 -- -- -- -- 3890 -- -- 3110 -- -- KSTI248 MSTI48 12 2-1/16 48 48 48 10d x 1-1/2 -- -- -- -- 5140 -- -- 4145 -- -- KSTI260 MSTI60 12 2-1/16 60 60 60 10d x 1-1/2 -- -- -- -- 5140 -- -- 5140 -- -- KSTI272 MSTI72 12 2-1/16 72 72 60 10d x 1-1/2 -- -- -- -- 5140 -- -- 5140 -- -- KST260 MST60, S/MST60 10 2-1/16 60 72 64 16d 10 1/2 6720 4910 6720 4390 KST272 MST72, S/MST72 10 2-1/16 72 72 64 16d 10 1/2 6720 4910 6720 4390
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) Allowable loads are based on the use of either nails or bolts; nail and bolt values cannot be combined. 3) Minimum nail embedment shall be 1-5/8˝ for 16d nails. 4) Total number of nail and/or bolt holes provided in the strap. 5) Minimum quantity of fasteners to be installed with equal fasteners at each end of the connection. Product may have additional nail holes not needed to meet published allowable load of product. 6) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 7) Allowable bolt loads are based on parallel-to-grain loading, minimum of 2-1/2˝ thick. New products or updated product information are designated in bold font.
10, F16,R14
USPStock No.
SteelGauge
Total
Qty4
CodeRef.
Dimensions Fastener Schedule3,6 Allowable Uplift Loads (Lbs.)1,2
Nails Bolts DF-L / SP S-P-F / Hem Fir
An
gle
s &
Str
ap
s
1-800-328-5934 • www.USPconnectors.com76
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Strap Ties – KHST, KRPS, & PS series
KRPS – Meets IBC, IRC, UBC, & L.A. City requirements fornotched plates where plumbing, heating, or other pipes are placedin partitions.
PS – Piling Straps connect wood pilings to floor girders. Hot-dipgalvanized for corrosion protection in coastal environments.
KHST – Heavy-capacity strap that utilizes bolts.
Materials: See chartFinish: KHST – USP primer; KRPS – G90 galvanizing;
PS – Hot-dip galvanizedOptions: KRPS22 is available in Triple Zinc. To order, add
TZ to stock number, as in KRPS22-TZ. KHST2 &KHST3 are available in Hot-dipped galvanized. To order, add HDG to stock number, as in KHST2-HDG.
Codes: ESR-1280, FL11664, L.A. City RR 25749
Installation:• Use all specified fasteners. See Product Notes, page 11.
Typical KRPSinstallation
Built-upbeam
Piling
Typical PS720-HDGinstallation
3 3/4˝
6 3/4˝
1 1/4˝
20˝3˝
KHST3 and KHST2KHST6 and KHST5
KHST2KHST3
KHST5KHST6
W
WKHST KRPS
1 1/2˝
KRP
S22
5 1 / 2
˝ KR
PS28
12˝
L
end
of n
otch
dis
tanc
e
PS720-HDG
In some instances the codesrequire the use of a metalstrap where sill or top platesare cut, notched, or drilled. IRC R602.6.1, IBC 2308.9.8
DF-L / SP
Ref. No. W L Qty Type Qty Type 160%
KHST2 HST2, HST2-R 7 2-1/2 21-1/4 -- -- -- -- -- -- 6 5/8 5250
KHST3 HST3 3 3 25-1/2 -- -- -- -- -- -- 6 3/4 7920 KHST5 HST5 7 5 21-1/4 -- -- -- -- -- -- 12 5/8 10635
KHST6 HST6 3 6 25-1/2 -- -- -- -- -- -- 12 3/4 15935
PS218-HDG PS218 7 2 18 -- -- -- -- -- -- 4 5/8 -- -- PS418-HDG PS418 7 4 18 -- -- -- -- -- -- 4 5/8 -- --
PS720-HDG PS720 7 6-3/4 20 -- -- -- -- -- -- 8 5/8 -- -- KRPS22 RPS18, RPS22 16 1-1/2 22-5/16 < 5-1/2˝ 16 16d -- -- -- -- 1720
KRPS28 RPS28 16 1-1/2 28-5/16 < 12˝ 16 16d -- -- -- -- 1720
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) Minimum nail embedment shall be 1-5/8˝ for 16d nails. 3) Allowable loads are based on single shear, parallel to grain loading with a 4˝ minimum member thickness for KHST2 and KHST5, and 4-1/2˝ minimum member thickness for KHST3 and KHST6. 4) PS piling strap design loads must be determined for each installation. Bolts are installed perpendicular and parallel-to-grain.
2,F20,R12
120
130
Nails Bolts
Allowable Tension
Loads (Lbs.)1,3
Fastener Schedule2
CodeRef.
Dimensions
USP
Stock No.4Steel
Gauge
NotchWidth
2 1/2˝
W
1˝
L
PS218-HDGPS418-HDG similar
USP2173-111
An
gle
s &
Stra
ps
1-800-328-5934 • www.USPconnectors.com 77
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Pre-Bent Strap – MSTC66B3
Minimum(2) 2x or 4x
Minimum Length 22˝
StudFastening
No NailsRequired
Face Nailing3˝ MinimumBearing Area
The MSTC66B3 Pre-Bent Strap is designed tofasten vertical studs to a beam or ridge beammember below where the beam depth will notallow complete fastener attachments with astandard product.
Materials: 14 gaugeFinish: G90 galvanizing
Installation:• Use all specified fasteners. See ProductNotes, page 11.
DF-L / SP S-P-F
Ref. No. W L B W D Qty Face Qty Bottom Qty Type 160% 160%
MSTC66B3 MSTC66B3 14 3 62-7/8 2-7/8 3 11-1/4 14 10d 4 10d 28 10d 5495 4250 130
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) Minimum nail embedment shall be 1-1/2˝ for 10d nails. 3) Minimum strap length on stud/post for quantity of nails is 22". 4) The 3" wide beam may be double for 2x members. 5) Fewer fasteners in the stud/post than listed will reduce the capacity of the connection. 6) Nails in the stud/post to be installed symmetrically in pairs starting a minimum of 1-1/2" from the end.
CodeRef.
Minimum BeamDimensions
Strap Dimensions
USPStock No.
SteelGauge
Stud/Post3,5,6
Fastener Schedule2
Beam Uplift
Allowable Loads (Lbs.)1
2 7/8˝
62 7/8˝
3˝
Typical MSTC66B3installation
MSTC66B3
Sideview
An
gle
s &
Str
ap
s
1-800-328-5934 • www.USPconnectors.com78
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
Uplift
Equal number of specifiedfasteners at each end
Typical LTW12 / MTW12Stud-to-rim joist
installation
1 1/4˝
1˝Typ.
L
LTW18/MTW18other models similar
MTW30/HTW30
L1
L2
1 1/4˝
L2
L1
1 1/4˝
1˝ Typ.
LTW12/MTW12Typical LTW12 / MTW12
Truss-to-top plateinstallation
Typical MTW20I-Joist Rafterinstallation
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Uplift
Place strap so allnail holes alignwith rim joist
F1
F2
Typical LFTA6 stud-to-rimjoist installation
Typical LFTA6 truss-to-topplate installation
Twist straps tie framing members to resist tension forces.
LFTA6 – 16 gauge.
LTW – 18 gauge, light-capacity.
MTW – 16 gauge, medium-capacity.
HTW – 14 gauge, heavy-capacity.
Materials: See chartFinish: G90 galvanizing
Options: LFTA6, MTW12, MTW16 & MTW20 areavailable in Triple Zinc. To order, add TZ to stock number, as in MTW12-TZ. LTW12, LTW18 & MTW20 are available in Stainless Steel. To order, add SS to stock number, as in LTW18-SS.
Codes: ESR-2104, FL820, L.A. City RR 25745
Installation:• Use all specified fasteners. See Product Notes, page 11.• Consult I-Joist manufacturer for web stiffener
requirements, and uplift limitations on joist and application.
Twist Straps – HTW, LFTA6, LTW, & MTW series
LFTA6
Typical LFTA6 stud-to-topplate installation
19 1/8˝8 3/8˝
6 1/2˝2 1/4˝
continued on next page
USP2173-111
An
gle
s &
Stra
ps
1-800-328-5934 • www.USPconnectors.com 79
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Twist Straps – HTW, LFTA6, LTW, & MTW series cont.
DF-L / SP S-P-F
Uplift Uplift
Ref. No. W L L1 L2 Qty Type 160% 160%
12 10d x 1-1/2
12 10d
12 10d x 1-1/212 10d
12 10d x 1-1/212 10d
12 10d x 1-1/2
12 10d14 10d x 1-1/2
14 10d14 10d x 1-1/2
14 10d
14 10d x 1-1/214 10d
16 8d16 8d x1-1/2
14 10d x 1-1/2
14 10d14 10d x 1-1/2
14 10d14 10d x 1-1/2
14 10d
14 10d x 1-1/214 10d
14 10d x 1-1/214 10d
16 10d x 1-1/216 10d
24 10d x 1-1/2
20 10d24 10d x 1-1/2
20 10d24 10d x 1-1/2
20 10d
24 10d x 1-1/220 10d
24 10d x 1-1/220 10d
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) Minimum nail embedment shall be 1-5/16˝ for 8d nails and 1-1/2˝ for 10d nails. 3) 16d sinker nails may be substituted for 10d common nails with no reduction in load. 4) For 1-1/2˝ lumber, use 0.84 of table load for 10d nails and 0.77 for 16d nails. 5) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 8d x 1-1/2 nails are 11 gauge (0.131˝ diameter) by 1-1/2˝ long. 6) Fasteners shall be distributed equally on each end of the connection. 7) C after the model number designates center twist as in MTW30C. 8) LFTA6: F1 is 700 lbs and F2 is 90 lbs. To achieve F1 lateral loads, three nails must be installed on each side on the strap located closest to the bend line. Lateral F1 and F2 load directions do not apply to roof truss-to-top plate installations.
1530
1210
1195
6-1/2
8-1/2
7-1/8
1195
1195
1195
1530
7-1/2
6-1/2
7-1/2 7-1/2
8-1/2 8-1/2
USP
Stock No.7
SteelGauge
1-1/4
10-7/16
7-1/2 LTW18 LTS18
LTW20 LTS20
MTW12
Dimensions Allowable Loads (Lbs.)1Fastener
Schedule2,3,4,5,6
LTW16 LTS16 1-1/4
650
650
LTW12 4-1/2
MTS12, TS12, TS9
MTW16 MTS16
MTW18 MTS18, TS18
MTW20 MTS20
MTW30 MTS30
MTW24C MTS24C
MTW28C -- --
MTW30C MTS30C
HTW16 HTS16
HTW20 HTS20, TS22
HTW24 HTS24
HTW28 HTS28
HTW30 HTS30
HTW30C HTS30C
LTS12 18
18
18
18
16
16
16
16
16
16
16
16
14
14
14
14
14
14
12
16
18
20
12
16
18
24
20
30
24
28
1-1/4
30
16
20
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
4-1/2
6-1/2
4-1/2
8-1/2
7-1/8
1-1/4
1-1/4
1-1/4
1-1/4 28
12-1/812-1/8
7
11-1/8 11-1/8
17-1/430
30
5-1/8
4-1/2
6-1/2
13-7/16 13-7/16
8-5/16
12-7/16
18-9/16
10-7/16
12-7/16
9-1/8 9-1/8
LFTA6 H6 16 2-1/4 19-1/8 8-3/8 6-1/2
5-1/8
650
650
775
775
775
775
1005
1195
1195
1195
1195
1015
1005
1005
1005
1005
1005
1005
1005
1285
12851530
1260
1530
1530 1285
1285
1060
1285
CodeRef.
8, F14, R9
8, F14, R9
8, F14, R9
8, F14, R9
8, F14, R9
8, F14, R9
8, F14, R9
8, F14, R9
8, F14, R9
8, F14, R9
8, F14, R9
8, F14, R9
8, F14, R9
8, F14, R9
8, F14, R9
8, F14, R9
8, F14, R9
8, F14, R9
8, F14, R9
L1
L2
MTW30CTypical MTW30installation
An
gle
s &
Str
ap
s
1-800-328-5934 • www.USPconnectors.com80
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Masonry Straps MSTAM & MSTCM series
The MSTAM and MSTCM Strap Ties are designed toconnect a wood structure above to a masonry wall below.
Materials: See chartFinish: G90 galvanizing
Installation:• Use all specified fasteners.SeeProduct Notes, page 11.
Typical MSTCM40installation
Typical MSTAM36installation
3˝ minimum3˝ minimum
14˝minimum
12 1/2˝minimum
3˝ minimum3˝ minimum
14˝minimum
12 1/2˝minimum
DF-L / SP S-P-F
Ref. No. W L Qty Type Qty Type Qty Type 160% 160%
MSTAM24 MSTAM24 18 1-1/4 24 5 1/4˝ Tapcon 5 1/4˝ Tapcon 9 10d 1545 1455
MSTAM36 MSTAM36 16 1-1/4 36 8 1/4˝ Tapcon 8 1/4˝ Tapcon 13 10d 1945 194524 10d
20 16d
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) Allowable loads are derived from tests performed using hollow C90 concrete block. 3) Minimum nail embedment shall be 1-1/2˝ for 10d nails and 1-5/8˝ for 16d nails. 4) Use ITW Buildex 1/4˝ x 2-1/4˝ Tapcon fasteners; or equal, installed in accordance with manufacturer's specification.
CodeRef.
1301/4˝ Tapcon 14 1/4˝ Tapcon 3665
USPStock No.
SteelGauge
366514 MSTCM40 MSTCM40 16 3 40-1/4
Dimensions
Uplift
Allowable Loads (Lbs.)1,2
CMU4 Concrete4 Nails3
Fastener Schedule
DF-L / SP S-P-F
Qty Type Qty Type Qty Type 160% 160%
16 5 1/4˝ Tapcon 5 1/4˝ Tapcon 8 10d 1320 1320
18 5 1/4˝ Tapcon 5 1/4˝ Tapcon 7 10d 1320 1155
16 12 1/4˝ Tapcon 12 1/4˝ Tapcon 16 16d 3145 312518 12 1/4˝ Tapcon 12 1/4˝ Tapcon 14 16d 3145 2735
1) Use ITW Buildex 1/4˝ x 2-1/4˝ Tapcon fasteners; or equal, installed in accordance with manufacturer's specification. 2) Minimum nail embedment shall be 1-1/2˝ for 10d nails and 1-5/8˝ for 16d nails. 3) Allowable loads are derived from tests perrformed using hollow C90 concrete block.
Fastener Schedule Allowable Loads (Lbs.)1
CMU3
Concrete3
Nails2 Uplift
MSTAM36
MSTCM40
USPStock No.
ClearSpan
MSTCM40W
3˝
L
1 1/ 2˝
3˝
L
5/8˝
WMSTAM36
Clear Span Chart
Typical HTWMinstallation
USP2173-111
An
gle
s &
Stra
ps
1-800-328-5934 • www.USPconnectors.com 81
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Masonry Straps – HTWM series
1-800-328-5934 • www.USPconnectors.com
15˚ Max
Connector strap
OD1 D2
Hanger
Typical KSAinstallation
Typical KSAinstallation
KSA – 12 gauge
KHSA – 3 gauge. Designed for installation with bolts only.
Materials: See chartFinish: KSA – G90 galvanizing
KHSA – USP primerCodes: ESR-1280, FL11664, L.A. City RR 25749
Installation:• Use all specified fasteners. See Product Notes, page 11.• KSA36 can be field adjusted for smaller beam widths.
Typical KHSA4installation
Allowable loadsO
18º Max
The HTWM Twist Straps are designed for truss to concrete or masonry connections.Offer uplift resistance with variable heel height and positioning applications.
Materials: 14 gaugeFinish: G90 galvanizingCodes: FL6223
Installation Instructions:• Use all specified fasteners. See Product Notes pages 11.• Strap may be attached to either side of grouted masonry or concrete wall with a minimum of (1) #5 horizontal rebar.• Drill hole in concrete or masonry with manufacturers prescribed 1/4˝ masonry drill.Install fasteners into concrete or masonry per manufacturer’s specification.• Grout or concrete compressive strength shall be 2,000 psi at 28 days.• Twist straps do not have to be wrapped over the truss to achieve the allowable loads.• Moisture barrier may be required.
L1
L1
L
W
W
HTWM
DF-L / SP S-P-F
Ref. No. W L L1 Qty Qty Qty 160% 160%
HTWM16 HTSM16, MTSM16 14 1-1/4 16 5-3/4 4 1/4˝ x 1-3/4˝ 4 1/4˝ x 1-3/4˝ 8 10d x 1-1/2 1225 1145
HTWM20 HTSM20, MTSM20 14 1-1/4 20 7-3/4 4 1/4˝ x 1-3/4˝ 4 1/4˝ x 1-3/4˝ 8 10d x 1-1/2 1225 1145
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 3) Use Powers Fasteners 1/4˝ x 1-3/4˝ Wedge-Bolt®; or equal, installed in accordance with manufacturer's specification.
CodeRef.
F26
Dimensions
CMU3
WedgeBolts
Fastener Schedule
Concrete3
WedgeBolts
Truss/Rafter2
NailType
Uplift
Allowable Loads (Lbs.)1
USPStock No.
SteelGauge
Connector Straps – KHSA & KSA series
continued on next page
An
gle
s &
Str
ap
s
1-800-328-5934 • www.USPconnectors.com82
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
WL
0
KHSA5
W
L
0
DF-L / SP
Ref. No. W L O D1 D2 Qty Type 160%
22 16d 2620
4 1/2 2015 KHSA1 HSA32 3 3 30 9 10 -- -- 2 3/4 2435
KHSA2 HSA41 3 3 38-1/2 9 10 4-1/2 4 3/4 4810
KHSA3 HSA50 3 3 47 9 10 4-1/2 6 3/4 7005 KHSA4 HSA59 3 3 56 9 10 4-1/2 8 3/4 8920
KHSA5 HSA68 3 3-1/2 64-1/2 9 10 4-1/2 10 3/4 10785
1) Allowable loads are based on the use of either nails or bolts; nail and bolt values cannot be combined. 2) Bolt values assume wood member thickness of 3-1/2˝ with bolts in single shear. 3) Minimum nail embedment shall be 1-5/8˝ for 16d nails. 4) Bolts shall be loaded parallel to grain.
CodeRef.
2,F20,R12
USPStock No.
SteelGauge
KSA36 SA36 12 92-1/16 37-7/8 6-11/16 4-1/2
Allowable Tension
Loads (Lbs.)1,2
Fastener
Schedule 3,4
Dimensions
KSA36
Connector Straps – KHSA & KSA series continued
Knee Braces – KVB & KVBI series
2˝
L
Ref. No. Beam Depth L Qty Type Qty Type 100% 125% 160%
KVB5 VB5 12 10 - 15 60 4 WS3 12 WS3 1800 1800 1800
KVB7 VB7 12 15 - 22-1/2 84 4 WS3 12 WS3 1800 1800 1800
KVB8 VB8 12 22-1/2 - 28-1/2 96 4 WS3 12 WS3 1800 1800 1800 KVB10 VB10 12 28-1/2 - 36 120 4 WS3 12 WS3 1800 1800 1800
KVB12 VB12 12 36 - 42 144 4 WS3 12 WS3 1800 1800 1800 KVBI5 -- -- 12 10 - 15 60 4 10d 12 10d 760 955 1220
KVBI7 -- -- 12 15 - 22-1/2 84 6 10d 12 10d 760 955 1220
KVBI8 -- -- 12 22-1/2 - 28-1/2 96 6 10d 12 10d 760 955 1220 KVBI10 -- -- 12 28-1/2 - 36 120 6 10d 12 10d 760 955 1220
KVBI12 -- -- 12 36 - 42 144 6 10d 12 10d 760 955 1220
1) WS3 Wood Screws are 1/4" x 3˝ long and are included KVB models. 2) Minimum nail embedment shall be 1-1/2˝ for 10d nails. New products or updated product information are designated in bold font.
Allowable Tension Loads (Lbs.)Dimensions (inches) Fastener Schedule1,2
Beam Joist CodeRef.
2,F20,R12
USPStock No.
SteelGauge
DF-L / SP
KVB – Installs with WS3 wood screws for higher load capacity. It can be retrofit into existing framing.
KVBI – Installs with common nails. Designed to beused with I-Joist purlins.
Materials: 12 gaugeFinish: G90 galvanizingCodes: ESR-1280, FL11664,
L.A. City RR 25749
Installation:• Use all specified fasteners. See Product Notes, page 11.• WS3 wood screws are included with KVB shipments.• Install flanges at angles of 45° or more to the vertical plane to assure proper lateral resistance.
Typical KVB7installation
KVB5
USP2173-111
An
gle
s &
Stra
ps
1-800-328-5934 • www.USPconnectors.com 83
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Permanent Wood Foundation Strap – PWFS24
DF-L / SP S-P-F
Ref. No. W L Qty Type 100% 100%
PWFS24 -- -- 20 1-1/2 24 9 8d 775 645 130
1) Minimum nail embedment shall be 1-5/16˝ for 8d nails. 2) For installations where the strap does not fall behind joist, the designer shall be be responsible to determine suitability of rim to resist the load.
CodeRef.
Allowable Loads (Lbs.)
USPStock No.
SteelGauge
Dimensions Fastener Schedule
PWFS24
Typical PWFS24installation
Loaddirection
1 1/2˝
24˝
Connects permanent wood foundation studs to rim joist toresist lateral loads produced from ground pressure. The highload values and positive placement nail gun installation makethe PWFS24 practical for manufactured homes as well assite built homes.
Materials: 20 gaugeFinish: G90 galvanizing
Installation:• Use all specified fasteners. See Product Notes, page 11.• Center strap on top plate over the stud.• Attach center nail and bend inside end of strap downward.• Install nails on inside of wall.• Install floor system or place manufactured home on foundation.• Form outside end of strap up the outside ofrim and install nails.
Han
gers
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com84
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Supported / Joist Member Supporting / Header Member
HangerType
USPSeries
SteelGauge F
ace
Mou
nt
Top
Mou
nt
Slo
ped
/ Ske
wed
For
med
Wel
ded
Dim
ensi
onal
Woo
d
EW
P
Tru
ss
Glu
lam
Dim
ensi
onal
Woo
d
EW
P
Tru
ss
Glu
lam
Mas
onry
DF-
L / S
P
Mas
onry
JL 20 • • • • • • 455 - 1,965 -- --
JLIF-TZ 18 • • • • • • 465 - 1,900 -- -- SUH 16 • • • • • • 465 - 2,760 -- --
JUS 18 • • • • • • 655 - 2,935 -- -- MUS 18 • • • • • • 1285 - 2,140 -- --
16 • • • • • • • • 2,635 - 5,510 -- --
14 • • • • • • • • 800 - 3,225 -- -- HD 14 • • • • • • • • • 565 - 4,570 -- --
HDQ 14 • • • • • • • • • 3,340 - 5,590 -- -- HDO 12 • • • • • • • 2,170 - 6,210 -- --
SW 12 • • • • • 2,315 - 2,520 -- --
SWH7 - Top Flange
12 - Stirrup • • • • • • 3,305-- --
KHW3 - Top Flange
10 - Stirrup • • • • • 5,295 - 5,335-- --
HL 18 • • • • 1,270 - 1,590 -- -- JH 18 • • • • • • • 1,900 - 2,900 -- --
LS 18 • • • • • 785 - 1,370 -- --16 • • • • • • • • • • 510 - 2,500 -- --
14 • • • • • • • • • • 1,410 - 3,880 -- --
SKHH 14 • • • • • • • • • • 1,510 - 4,550 -- -- KF 18 • • • • • 695 - 810 -- --
PHG 18 • • • • • 580 - 650 -- -- FHD 18 • • • • • 960 - 1,235 -- --
JDS 18 • • • • • 480 - 1,670 -- --
JPF 20 • • • • • 1,070 - 1,275 -- --
HWUH1/4˝ - Top Flange,
7 - Stirrup • • • • • • • -- -- 2,265 - 5,165
MPH 12 • • • • • • -- -- 2,585 - 4,280
UHM 1/4˝ • • • • • • -- -- 3,550 - 6,380
NFM3/8˝ - Top Flange,
7 - Stirrup • • • • • -- -- 7,130 - 10,310
• Represents common applications and product configurations. Consult USP for additional applications and/or optional product configurations.
Style
FaceMount
100% Allowable Loads (Lbs.) Range
HUS
SKH
Header Material
Masonry
TopMount
Slopeand
Skew
Paneland
Purlin
Hanger Selector Guide
Hangers
1-800-328-5934 • www.USPconnectors.com
USP2173-111
Han
gers
1-800-328-5934 • www.USPconnectors.com 85
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
JUSMUS Similar
Face Mount Joist Hangers . . . . . . . . . . . . . Pages 87-95• JL SeriesLight-capacity 20 gauge 2x joist hanger.
• JLIF-TZ SeriesMedium-capacity inverted flange18 gauge joist hanger.
• SUH SeriesMedium-capacity 16 gauge joist hanger.
• JUS SeriesMedium-capacity 18 gauge joist hanger with slant nailing.
• MUS SeriesMedium-capacity 18 gauge joist hanger with slant nailing.
• HUS SeriesHeavy-capacity 14 or 16 gauge joist hanger with slant nailing.
• HD SeriesHeavy-capacity 14 gauge inverted flange joist hanger.
• HDQ Series Heavy-capacity 14 gauge inverted flange joist hanger.
Top Mount Hangers . . . . . . . Pages 96-101• HDO SeriesMedium-capacity 12 gauge top mount hanger with uplift capacity.
• SW SeriesLight-capacity welded hanger with primer finish.
• SWH SeriesMedium-capacity welded hanger with primer finish.
• KHW SeriesHeavy-capacity welded hanger with primer finish.
• HL SeriesLight-capacity 18 gauge 2x top mount hanger.
• JH SeriesMedium-capacity strap style hanger.
Slope & Skew Hangers . . . . Pages 101-103• LS SeriesLight-capacity hanger for slopes of 0° to 30° down.
• SKH SeriesLight-capacity 45° skewed hanger.
• SKHH SeriesMedium-capacity 45° skewed hanger.
HD
HL
SW SWH
KHW JH
HDO
HUS
HDQ
JL SUHJLIF-TZ
Hangers
continued on next page
SKH SKHHLS
Han
gers
1-800-328-5934 • www.USPconnectors.com86
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Panel & Purlin Hangers . . . . . . . . . Pages 104-105• KF SeriesPanel hanger with a joist end nail.
• PHG SeriesPanel hanger that uses a gripper instead of a nail.
• JDS SeriesMedium-capacity purlin saddle hanger.
• JPF SeriesMedium-capacity purlin hanger with double shear nailing.
Masonry Hangers . . . . . . . Pages 106-110• HWUH SeriesHeavy-capacity top flange masonry hanger.
• MPH SeriesTop flange masonry hanger.
• UMH SeriesFace mount masonry hanger.
• NFM SeriesNarrow flange hanger for headers connecting to theend of a masonry wall.
KF
MPHHWUH UMH NFM
JDS JPF
PHG
Hangers
Typical SUH26-2installation
USP2173-111
Han
gers
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com 87
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Standard Joist Hangers – JL, JL-IF, & SUH series
USP offers a wide variety of light-gauge face mount joist hangers toaccommodate application and installation preferences.
JL series – 20 gauge, 2x joist hangers.JL-IF series – 18 gauge, 2x joist hangers.SUH series – 16 gauge steel construction for more demanding applications and light truss support.
Materials: See chartFinish: G90 galvanizing
Options: See SUH Specialty Options Chart.Codes: ESR-1781, ESR-1280, L.A. City RR 25749,
L.A. City RR 25843, FL571, FL11664, FL13285, Dade County, FL 07.0214.20
Installation:• Use all specified fasteners. See Product Notes, page 11.
A
H
DWJL26
SUH26-2
Typical JL26installation
Option4 Skewed 1,3 Sloped Seat2,3 Sloped / Skewed1,2,3
Range
Ordering
AllowableLoads
100% of table load
1˚ to 45˚
Add SK angle required,and right (R)or left (L),
to product number.Ex. SUH210-SK45R
Add SL,slope required,and up (U)or down (D),
to product number.Ex. SUH210-SL30D
See Sloped Seat and Skewed.Ex. SUH210-SK45RSL30D
See Sloped Seat and Skewed
1˚ to 67-1/2˚when width is1-3/4˝ or less.
1˚ to 50˚ on all others.
100% of table load.75% of uplift loadon skews greater
than 15˚.
80% of table load.75% of uplift loadon skews greater
than 15˚.
SUH Specialty Options Chart – refer to SpecialtyOptions pages 194 to 195 for additional details.
1) Skewed hangers with skews greater than 15° may have all joist nailing on outside flange. 2) Sloped or sloped / skewed hangers with slopes greater than 15° may have additional joist nails. 3) All sloped, skewed, or combinations require bevel cut on joist in all applications and web stiffeners with I-Joists. 4) Some SUH option hangers may be manufactured as welded products to achieve listed loads.
JL-IF
Typical JL-IFinstallation
Han
gers
1-800-328-5934 • www.USPconnectors.com88
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
A
H
DW
Dimple allows 30º
to 45˚nailing
JUS28
HUS28-2MUS
Typical HUS410IF invertedflange installation
Typical HUS46installation
The HUS, JUS & MUS hanger series offers double shear nailing. USP’s dimple allowsfor 30° to 45° nailing through the joist into the header resulting in higher loads and lessnailing. Slant nailing also eliminates the need for shorter joist nails in 2x applications.
Materials: JUS - 18 gauge; MUS - 18 gauge; HUS - 14 or 16 gaugeFinish: G90 galvanizing;
JUS24-GC, JUS26-GC, JUS210-GC, JUS26-2GC, & JUS210-2GC – Gold Coat
Options: HUS28-2IF, HUS210-2IF, JUS24, JUS26, JUS26-2, JUS28, JUS28-2, JUS210, JUS210-2, JUS44, JUS46, JUS28-3, & JUS210-3 are available in Triple Zinc. To order, add TZ to stock number, as in JUS24 -TZ. JUS24, JUS26, JUS26-2, JUS28, JUS210, and JUS210-2 are available in Stainless Steel. To order, add SS to stock number, as in JUS26-SS. See HUS Specialty Options Chart.
Codes: ESR-1881, FL9835, FL570, FL821, FL571,Dade County, FL 07-0419.01, Dade County, FL 07-0214.20 & Dade County, FL 06-0921.05, L.A. City RR 25779
Installation:• Use all specified fasteners. See Product Notes, page 11.• Joist nails must be driven at a 30° to 45° angle through the joist or truss into the header to achieve listed loads. Standard length “double shear” nails must be usedto achieve listed load values.• JUS & MUS - 16d sinkers (9 gauge x 31⁄4˝ ) may be used where 10d commons are specified with no load reduction.
Typical JUS46installation
Option Inverted Flange
Not available inwidths less than 2-1/4˝.
100% of table load.65% of table load whennailing into the supportmembers end grain.
Add IFto product number.
Ex. HUS410IFOrdering
AllowableLoads
Range
HUS Specialty Options Chart – referto Specialty Options pages 194-195for additional details.
Double shear nail designfeatures fewer nails and
faster installation
Uses standard length nails
1-800-328-5934 • www.USPconnectors.com
Slant Nail Joist Hangers – HUS, JUS & MUS series
NEW
USP2173-111
Han
gers
1-800-328-5934 • www.USPconnectors.com 89
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
HDQ inverted flange hangers install with woodscrews eliminating the need to drill bolt holes simplifying installation.
Materials: 14 gaugeFinish: G90 galvanizing
Installation:• Use all specified fasteners. See Product Notes,page 11.• WS15 and WS3 Wood Screws are supplied withHDQ hangers.
Heavy-Duty Face Mount Hangers – HD series
Typical HD210-2installation
A
D W
H
HD51135
Bend linenailing
A
H
DW
HD610
HD hangers are heavy-duty face mount hangers that canbe used to support headers, joists, and trusses.
Materials: 14 gaugeFinish: G90 galvanizing
Options: All nominal lumber sizes are available rough/full size lumber. See Specialty Options Chart.
Codes: ESR-1781, FL13285, L.A. City RR 25843
Installation:• Use all specified fasteners. See Product Notes, page 11.• Some HD models feature nail holes along bend line thatmust be filled to achieve allowable loads. Verify properheader width to accomplish this for inverted models.
Drive bend line nailsinto header at 45°
to achieve listed loads.
Typical HD210-2IFinverted flange
installation
Option 4 Skewed1,3 Sloped Seat2,3 Sloped / Skewed1,2,3 Inverted Flange
1) Skewed hangers with skews greater than 15° may have all joist nailing on outside flange. 2) Sloped or sloped / skewed hangers with slopes greater than 15° may have additional joist nails. 3) All sloped, skewed, or combinations require bevel cut on joist in all applications and web stiffeners with I-joists. Hangers for square-cut joists are available as a Custom. Further reductions in allowable loads may apply. 4) Modifications of HD hangers may be manufactured as hot rolled, welded, or primed. New products or updated product information are designated in bold font.
1˚ to 67-1/2˚when width is1-3/4˝ or less.
1˚ to 50˚ on all others.
1˚ to 45˚ See Sloped Seat and Skewed
100% of table load
80% of table load.75% of uplift loadon skews greater
than 15˚.
Range
Ordering
AllowableLoads
Not available inwidths less than 2-1/4˝
100% of table load.75% of uplift loadon skews greater
than 15˚.
100% of table load.65% of table load whennailing into the supportmembers end grain.
See Sloped Seat and Skewed.Ex. HD410-SK45RSL30D
Add IFto product number.
Ex. HD410IF
Add SK,angle required,and right (R) or left (L),
to product number.Ex. HD410-SK45R
Add SL,slope required,and up (U) or down (D),
to product number.Ex. HD410-SL30D
Specialty Options Chart – refer to Specialty Options pages 194 to 195 for additional details.
Typical HD3212glulam installation
Typical HD610installation
Inverted Flange Hangers – HDQ series
H
3˝W Typical HDQ-IFinstallation
Up to 3/4˝ gap
HDQ-IF
Han
gers
1-800-328-5934 • www.USPconnectors.com90
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Floor Uplift1
Joist Size Ref. No. W H D A Qty Nail Qty Nail 100% 115% 125% 160%
20 1-9/16 3 1-1/2 15/16 4 10d 2 10d x 1-1/2 455 525 570 245
20 1-9/16 3 1-1/2 15/16 4 16d 2 10d x 1-1/2 545 625 680 245
18 1-9/16 3-1/8 1-1/2 -- -- 4 10d 2 10d x 1-1/2 465 480 480 305
18 1-9/16 3-1/8 1-1/2 -- -- 4 16d 2 10d x 1-1/2 480 480 480 305
JUS24 LUS24 18 1-9/16 3-1/8 1-3/4 1 4 10d 2 10d 655 750 820 510 JUS24-GC -- -- 18 1-9/16 3-1/8 1-3/4 1 4 N10C-GC 2 N10C-GC 655 750 820 510
16 1-9/16 3-1/4 2 1-3/16 4 10d 2 10d x 1-1/2 465 535 580 360
16 1-9/16 3-1/4 2 1-3/16 4 16d 2 10d x 1-1/2 550 635 690 360 HD26 HU26 14 1-9/16 3-1/2 2 1-1/8 4 16d 2 10d x 1-1/2 565 650 705 290 5, F30, R5
20 1-9/16 4-3/4 1-1/2 15/16 6 10d 4 10d x 1-1/2 685 785 855 48520 1-9/16 4-3/4 1-1/2 15/16 6 16d 4 10d x 1-1/2 815 940 1020 485
18 1-9/16 4-1/2 1-1/2 -- -- 6 10d 4 10d x 1-1/2 695 800 870 730
18 1-9/16 4-1/2 1-1/2 -- -- 6 16d 4 10d x 1-1/2 830 950 1035 730
JUS26 LUS26 18 1-9/16 4-13/16 1-3/4 1 4 10d 4 10d 850 975 1060 1115
JUS26-GC -- -- 18 1-9/16 4-13/16 1-3/4 1 4 N10C-GC 4 N10C-GC 850 975 1060 1115 MUS26 MUS26 18 1-9/16 5-1/16 2 1 6 10d 6 10d 1285 1475 1605 865 110
16 1-9/16 5-1/8 2 1-3/16 6 10d 4 10d x 1-1/2 695 800 870 725
16 1-9/16 5-1/8 2 1-3/16 6 16d 4 10d x 1-1/2 830 950 1035 725
HUS26 HUS26 16 1-5/8 5-7/16 3 2 14 16d 6 16d 2635 3030 3295 1925 6, F15, F18,
D2, R13
HD26 HU26 14 1-9/16 3-1/2 2 1-1/8 4 16d 2 10d x 1-1/2 565 650 705 290
HD28 HU28 14 1-9/16 5-1/4 2 1-1/8 8 16d 4 10d x 1-1/2 1130 1295 1410 73020 1-9/16 4-3/4 1-1/2 15/16 6 10d 4 10d x 1-1/2 685 785 855 485
20 1-9/16 4-3/4 1-1/2 15/16 6 16d 4 10d x 1-1/2 815 940 1020 48518 1-9/16 4-1/2 1-1/2 -- -- 6 10d 4 10d x 1-1/2 695 800 870 730
18 1-9/16 4-1/2 1-1/2 -- -- 6 16d 4 10d x 1-1/2 830 950 1035 730
20 1-9/16 6-3/8 1-1/2 15/16 10 10d 6 10d x 1-1/2 1140 1295 1295 88520 1-9/16 6-3/8 1-1/2 15/16 10 16d 6 10d x 1-1/2 1360 1565 1700 885
18 1-9/16 6-1/8 1-1/2 -- -- 8 10d 4 10d x 1-1/2 930 1065 1160 73018 1-9/16 6-1/8 1-1/2 -- -- 8 16d 4 10d x 1-1/2 1105 1215 1215 730
JUS26 LUS26 18 1-9/16 4-13/16 1-3/4 1 4 10d 4 10d 850 975 1060 1115
JUS26-GC -- -- 18 1-9/16 4-13/16 1-3/4 1 4 N10C-GC 4 N10C-GC 850 975 1060 1115 JUS28 LUS28 18 1-9/16 6-5/8 1-3/4 1 6 10d 4 10d 1075 1235 1345 1115
JUS28-GC -- -- 18 1-9/16 6-5/8 1-3/4 1 6 N10C-GC 4 N10C-GC 1075 1235 1345 1115 MUS26 MUS26 18 1-9/16 5-1/16 2 1 6 10d 6 10d 1285 1475 1605 865
MUS28 MUS28 18 1-9/16 7-1/16 2 1 8 10d 8 10d 1710 1970 2140 1230
16 1-9/16 5-1/8 2 1-3/16 6 10d 4 10d x 1-1/2 695 800 870 72516 1-9/16 5-1/8 2 1-3/16 6 16d 4 10d x 1-1/2 830 950 1035 725
16 1-9/16 6-5/8 2 1-3/16 8 10d 6 10d x 1-1/2 930 1065 1160 80016 1-9/16 6-5/8 2 1-3/16 8 16d 6 10d x 1-1/2 1105 1270 1380 800
HUS26 HUS26 16 1-5/8 5-7/16 3 2 14 16d 6 16d 2635 3030 3295 1925
HUS28 HUS28 16 1-5/8 7-3/16 3 2 22 16d 8 16d 3970 4345 4345 2570 HD28 HU28 14 1-9/16 5-1/4 2 1-1/8 8 16d 4 10d x 1-1/2 1130 1295 1410 730
HD210 HU210 14 1-9/16 7-3/16 2 1-1/8 12 16d 4 10d x 1-1/2 1690 1945 2115 730
20 1-9/16 6-3/8 1-1/2 15/16 10 10d 6 10d x 1-1/2 1140 1295 1295 885
20 1-9/16 6-3/8 1-1/2 15/16 10 16d 6 10d x 1-1/2 1360 1565 1700 885
18 1-9/16 6-1/8 1-1/2 -- -- 8 10d 4 10d x 1-1/2 930 1065 1160 730
18 1-9/16 6-1/8 1-1/2 -- -- 8 16d 4 10d x 1-1/2 1105 1215 1215 730
20 1-9/16 8-1/4 1-1/2 15/16 14 10d 8 10d x 1-1/2 1595 1835 1875 1095
20 1-9/16 8-1/4 1-1/2 15/16 14 16d 8 10d x 1-1/2 1905 1965 1965 1095
18 1-9/16 8-1/4 1-1/2 -- -- 11 10d 6 10d x 1-1/2 1275 1465 1595 1095
18 1-9/16 8-1/4 1-1/2 -- -- 11 16d 6 10d x 1-1/2 1520 1745 1900 1095 JUS28 LUS28 18 1-9/16 6-5/8 1-3/4 1 6 10d 4 10d 1075 1235 1345 1115
JUS28-GC -- -- 18 1-9/16 6-5/8 1-3/4 1 6 N10C-GC 4 N10C-GC 1075 1235 1345 1115
JUS210 LUS210 18 1-9/16 7-3/4 1-3/4 1 8 10d 4 10d 1305 1500 1630 1115
JUS210-GC -- -- 18 1-9/16 7-3/4 1-3/4 1 8 N10C-GC 4 N10C-GC 1305 1500 1630 1115
MUS28 MUS28 18 1-9/16 7-1/16 2 1 8 10d 8 10d 1710 1970 2140 1230 11016 1-9/16 6-5/8 2 1-3/16 8 10d 6 10d x 1-1/2 930 1065 1160 800
16 1-9/16 6-5/8 2 1-3/16 8 16d 6 10d x 1-1/2 1105 1270 1380 800
16 1-9/16 8 2 1-3/16 10 10d 6 10d x 1-1/2 1160 1335 1450 108516 1-9/16 8 2 1-3/16 10 16d 6 10d x 1-1/2 1380 1585 1725 1085
HUS28 HUS28 16 1-5/8 7-3/16 3 2 22 16d 8 16d 3970 4345 4345 2570 HUS210 HUS210 16 1-5/8 9-3/16 3 2 30 16d 10 16d 5310 5510 5510 3205
HD210 HU210 14 1-9/16 7-3/16 2 1-1/8 12 16d 4 10d x 1-1/2 1690 1945 2115 730 5, F30, R5
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 3) Minimum nail embedment shall be 1-1/2˝ for 10d and N10C-GC nails; 1-5/8˝ for 16d and N16C-GC nails. 4) 16d sinkers (9 gauge x 3-1/4˝ long) may be used at 0.84 of the table load where 16d commons are specified. 5) For JUS and HUS hangers: Nails must be driven at a 30° to 45˚ angle through the joist or truss into the header to achieve the table loads. 6) WS15 Wood Screws are 1-1/4˝ x 1-1/2˝ long and are included with HDQ hangers. 7) WS3 Wood Screws are 1-1/4˝ x 3˝ long and are included with HDQ hangers.
5, F30, R5
6, F15, F18,D2, R13
6, F6,F15, D3, R13
6, F6,F15, D3, R13
6, F6,F15, D3, R13
2, F20,R12
5, F6,F30, D3, R5
110
5, F6,F30, D3, R5
110
110
5, F6,F30, D3, R5
110
6, F6,F15, D3, R13
2, F20,R12
5, F6,F30, D3, R5
110
6, F15, F18,D2, R13
5, F30, R5
CodeRef.
5, F6,F30, D3, R5
110
2, F20,R12
5, F6,F30, D3, R5
110
2, F20,R12
Dimensions Fastener Schedule2,3,4,6,7
Header Joist
USPStock No.
SteelGauge
SUH210 U210
JL210IF-TZ LUC210Z
SUH28 -- --
U26
SUH28 -- --
2 x 10
JL28 LU28
JL28IF-TZ LUC28Z
JL210 LU210
2 x 8
JL26 LU26
JL26IF-TZ LUC26Z
JL28 LU28
JL28IF-TZ LUC28Z
SUH26
2 x 6
JL26 LU26
JL26IF-TZ LUC26Z
SUH26 U26
Allowable Loads (Lbs.)
DF-L / SP
Roof
2 x 4
JL24 LU24
JL24IF-TZ -- --
SUH24 U24
A
H
DWcontinued on next page
1-800-328-5934 • www.USPconnectors.com
Face Mount Hanger Charts
USP2173-111
Han
gers
1-800-328-5934 • www.USPconnectors.com 91
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Face Mount Hanger Charts continued
Floor Uplift1
Joist Size Ref. No. W H D A Qty Nail Qty Nail 100% 115% 125% 160%20 1-9/16 8-1/4 1-1/2 15/16 14 10d 8 10d x 1-1/2 1595 1835 1875 1095
20 1-9/16 8-1/4 1-1/2 15/16 14 16d 8 10d x 1-1/2 1905 1965 1965 109518 1-9/16 8-1/4 1-1/2 -- -- 11 10d 6 10d x 1-1/2 1275 1465 1595 1095
18 1-9/16 8-1/4 1-1/2 -- -- 11 16d 6 10d x 1-1/2 1520 1745 1900 1095
JUS210 LUS210 18 1-9/16 7-3/4 1-3/4 1 8 10d 4 10d 1305 1500 1630 1115
JUS210-GC -- -- 18 1-9/16 7-3/4 1-3/4 1 8 N10C-GC 4 N10C-GC 1305 1500 1630 1115
16 1-9/16 8 2 1-3/16 10 10d 6 10d x 1-1/2 1160 1335 1450 108516 1-9/16 8 2 1-3/16 10 16d 6 10d x 1-1/2 1380 1585 1725 1085
HUS210 HUS210 16 1-5/8 9-3/16 3 2 30 16d 10 16d 5310 5510 5510 3205 6, F15, F18,
D2, R13
HD210 HU210 14 1-9/16 7-3/16 2 1-1/8 12 16d 4 10d x 1-1/2 1690 1945 2115 730 HD212 HU212 14 1-9/16 9-1/4 2 1-1/8 16 16d 6 10d x 1-1/2 2255 2595 2730 1065
16 1-9/16 10 2 1-1/8 12 10d 8 10d x 1-1/2 1390 1600 1740 133016 1-9/16 10 2 1-1/8 12 16d 8 10d x 1-1/2 1655 1905 2070 1330
HD212 HU212 14 1-9/16 9-1/4 2 1-1/8 16 16d 6 10d x 1-1/2 2255 2595 2730 1065
HD214 HU214 14 1-9/16 11-1/2 2 1-1/8 20 16d 6 10d x 1-1/2 2560 2660 2730 1065
16 1-9/16 10 2 1-1/8 12 10d 8 10d x 1-1/2 1390 1600 1740 133016 1-9/16 10 2 1-1/8 12 16d 8 10d x 1-1/2 1655 1905 2070 1330
HD212 HU212 14 1-9/16 9-1/4 2 1-1/8 16 16d 6 10d x 1-1/2 2255 2595 2730 1065
HD214 HU214 14 1-9/16 11-1/2 2 1-1/8 20 16d 6 10d x 1-1/2 2560 2660 2730 1065
HD216 HU216 14 1-9/16 13-1/2 2 1-1/8 24 16d 8 10d x 1-1/2 2785 2925 3015 1065
JUS24-2 LUS24-2 18 3-1/8 3-7/16 2 1 4 16d 2 16d 780 900 965 325 6, F5, R13
16 3-1/8 3-1/8 2 1-1/8 6 10d 2 10d 695 800 870 370
16 3-1/8 3-1/8 2 1-1/8 6 16d 2 10d 830 950 1035 370 HD24-2 HU24-2 14 3-1/8 3-1/2 2-1/2 1-1/8 4 16d 2 10d 565 650 705 320 5, F30, R5
HUS24-2 -- -- 14 3-1/8 3-7/16 2 1 4 16d 2 16d 800 920 1000 495 6, F15, R13
JUS26-2 LUS26-2 18 3-1/8 5-1/4 2 1 4 16d 4 16d 1015 1170 1220 1355
JUS26-2GC -- -- 18 3-1/8 5-1/4 2 1 4 N16C-GC 4 N16C-GC 1015 1170 1220 1355
16 3-1/8 5-1/16 2 1-1/8 8 10d 4 10d 930 1065 1160 740
16 3-1/8 5-1/16 2 1-1/8 8 16d 4 10d 1105 1270 1380 740 HD24-2 HU24-2 14 3-1/8 3-1/2 2-1/2 1-1/8 4 16d 2 10d 565 650 705 320 5, F30, R5
HUS24-2 -- -- 14 3-1/8 3-7/16 2 1 4 16d 2 16d 800 920 1000 495 6, F15, R13
HUS26-2 HUS26-2 14 3-1/8 5-1/4 2 1 4 16d 4 16d 1030 1185 1290 1115 6, F18,
F15, D2, R13
HD26-2 HU26-2 14 3-1/8 5-1/8 2-1/2 1-1/8 12 16d 6 10d 1690 1945 2095 1140 5, F30, R5
JUS26-2 LUS26-2 18 3-1/8 5-1/4 2 1 4 16d 4 16d 1015 1170 1220 1355
JUS26-2GC -- -- 18 3-1/8 5-1/4 2 1 4 N16C-GC 4 N16C-GC 1015 1170 1220 1355
JUS28-2 LUS28-2 18 3-1/8 7-1/8 2 1 6 16d 4 16d 1290 1485 1615 1355
16 3-1/8 5-1/16 2 1-1/8 8 10d 4 10d 930 1065 1160 740
16 3-1/8 5-1/16 2 1-1/8 8 16d 4 10d 1105 1270 1380 74016 3-1/8 6-1/4 2 1-1/8 10 10d 4 10d 1160 1335 1450 740
16 3-1/8 6-1/4 2 1-1/8 10 16d 4 10d 1380 1585 1725 740 HUS26-2 HUS26-2 14 3-1/8 5-1/4 2 1 4 16d 4 16d 1030 1185 1290 1115
HUS28-2 HUS28-2 14 3-1/8 7-1/8 2 1 6 16d 6 16d 1550 1780 1935 1810
HD26-2 HU26-2 14 3-1/8 5-1/8 2-1/2 1-1/8 12 16d 6 10d 1690 1945 2095 1140 HD28-2 HU28-2 14 3-1/8 7-1/8 2-1/2 1-1/8 14 16d 6 10d 1975 2270 2470 1140
JUS28-2 LUS28-2 18 3-1/8 7-1/8 2 1 6 16d 4 16d 1290 1485 1615 1355 JUS210-2 LUS210-2 18 3-1/8 9-1/8 2 1 8 16d 6 16d 1800 2070 2250 1980
JUS210-2GC -- -- 18 3-1/8 9-1/8 2 1 8 N16C-GC 6 N16C-GC 1800 2070 2250 1980
16 3-1/8 6-1/4 2 1-1/8 10 10d 4 10d 1160 1335 1450 74016 3-1/8 6-1/4 2 1-1/8 10 16d 4 10d 1380 1585 1725 740
16 3-1/8 8-9/16 2 1-1/8 14 10d 6 10d 1625 1870 2030 1115
16 3-1/8 8-9/16 2 1-1/8 14 16d 6 10d 1930 2220 2415 1115
HUS28-2 HUS28-2 14 3-1/8 7-1/8 2 1 6 16d 6 16d 1550 1780 1935 1810 6, F18,
F15, D2, R13
HD28-2 HU28-2 14 3-1/8 7-1/8 2-1/2 1-1/8 14 16d 6 10d 1975 2270 2470 1140 5, F30, R5
HUS210-2 HUS210-2 14 3-1/8 9-1/8 2 1 8 16d 8 16d 2065 2375 2580 2210 6, F18,
F15, D2, R13
HD210-2 HU210-2 14 3-1/8 9 2-1/2 1-1/8 18 16d 10 10d 2540 2920 3175 1905 5, F30, R5
HDQ210-2IF HUCQ210-2-SDS 14 3-1/4 9 3 1-1/2 12 WS3 6 WS3 5015 5590 5590 2975 110
5, F30, R5
2, F20,R12
6, F18,F15, D2, R13
2, F20,R12
2, F20,R12
6, F6,F15, D3, R13
5, F30, R5
2, F20, R12
5, F6,F30, D3, R5
110
2, F20,R12
6, F5,F15, D7, R13
6, F5,F15, D7, R13
5, F30, R5
6, F5,F15, D7, R13
2, F20,R12
2, F20,R12
5,F30, R5
CodeRef.
Allowable Loads (Lbs.)
DF-L / SP
Roof
(2) 2 x 10
SUH28-2 -- --
SUH210-2 U210-2
(2) 2 x 6
SUH26-2 U26-2
(2) 2 x 8
SUH26-2 U26-2
SUH28-2 -- --
2 x 16
SUH214 U214
(2) 2 x 4 SUH24-2 U24-2
SUH214 U214 2 x 14
2 x 12
JL210 LU210
JL210IF-TZ LUC210Z
SUH210 U210
Header Joist
USPStock No.
SteelGauge
Dimensions Fastener Schedule2,3,4,6,7
continued on next page
Han
gers
1-800-328-5934 • www.USPconnectors.com92
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Face Mount Hanger Charts continued
Floor Uplift1
Joist Size Ref. No. W H D A Qty Nail Qty Nail 100% 115% 125% 160%
JUS210-2 LUS210-2 18 3-1/8 9-1/8 2 1 8 16d 6 16d 1800 2070 2250 1980
JUS210-2GC -- -- 18 3-1/8 9-1/8 2 1 8 N16C-GC 6 N16C-GC 1800 2070 2250 198016 3-1/8 8-9/16 2 1-1/8 14 10d 6 10d 1625 1870 2030 1115
16 3-1/8 8-9/16 2 1-1/8 14 16d 6 10d 1930 2220 2415 1115
HUS210-2 HUS210-2 14 3-1/8 9-1/8 2 1 8 16d 8 16d 2065 2375 2580 2210 6, F18,
F15, D2, R13
HD210-2 HU210-2 14 3-1/8 9 2-1/2 1-1/8 18 16d 10 10d 2540 2920 3175 1905 5, F30, R5
HDQ210-2IF HUCQ210-2-SDS 14 3-1/4 9 3 1-1/2 12 WS3 6 WS3 5015 5590 5590 2975 110
HUS212-2 HUS212-2 14 3-1/8 11-1/8 2 1 10 16d 10 16d 2580 2965 3225 3060 6, F18,
F15, D2, R13
HD212-2 HU212-2 14 3-1/8 11 2-1/2 1-1/8 22 16d 10 10d 3100 3565 3880 1905 5, F30, R5
JUS210-2 LUS210-2 18 3-1/8 9-1/8 2 1 8 16d 6 16d 1800 2070 2250 1980 6, F5,
F15, D7, R13
JUS214-2 -- -- 18 3-1/8 13-1/8 2 1 12 16d 6 16d 2345 2700 2935 1980 6, F1516 3-1/8 8-9/16 2 1-1/8 14 10d 6 10d 1625 1870 2030 1115
16 3-1/8 8-9/16 2 1-1/8 14 16d 6 10d 1930 2220 2415 1115
HD210-2 HU210-2 14 3-1/8 9 2-1/2 1-1/8 18 16d 10 10d 2540 2920 3175 1905 5, F30, R5 HDQ210-2IF HUCQ210-2-SDS 14 3-1/4 9 3 1-1/2 12 WS3 6 WS3 5015 5590 5590 2975 110
HUS212-2 HUS212-2 14 3-1/8 11-1/8 2 1 10 16d 10 16d 2580 2965 3225 3060 6, F18,
F15, D2, R13
HD212-2 HU212-2 14 3-1/8 11 2-1/2 1-1/8 22 16d 10 10d 3100 3565 3880 1905 HD214-2 HU214-2 14 3-1/8 13 2-1/2 1-1/8 24 16d 10 10d 3385 3890 4230 1905
JUS214-2 -- -- 18 3-1/8 13-1/8 2 1 12 16d 6 16d 2345 2700 2935 1980 6, F15, R13 HD212-2 HU212-2 14 3-1/8 11 2-1/2 1-1/8 22 16d 10 10d 3100 3565 3880 1905
HD214-2 HU214-2 14 3-1/8 13 2-1/2 1-1/8 24 16d 10 10d 3385 3890 4230 1905
HD216-2 HU216-2 14 3-1/8 15 2-1/2 1-1/8 26 16d 12 10d 3665 4215 4570 228516 2-9/16 3-3/8 2 1-1/8 6 10d 2 10d x 1-1/2 695 800 850 360
16 2-9/16 3-3/8 2 1-1/8 6 16d 2 10d x 1-1/2 830 850 850 360 HD34 HU34 14 2-9/16 3 2 1-1/8 4 16d 2 10d x 1-1/2 565 650 705 290 5, F30, R5
JUS36 LUS36 18 2-9/16 5-5/16 2 1 4 16d 4 16d 1015 1170 1220 1355 6, F15, R13
16 2-9/16 3-3/8 2 1-1/8 6 10d 2 10d x 1-1/2 695 800 850 36016 2-9/16 3-3/8 2 1-1/8 6 16d 2 10d x 1-1/2 830 850 850 360
16 2-9/16 5-5/16 2 1-1/8 8 10d 4 10d x 1-1/2 930 1065 1160 72516 2-9/16 5-5/16 2 1-1/8 8 16d 4 10d x 1-1/2 1105 1270 1380 725
HD36 HU36 14 2-9/16 4-3/4 2 1-1/8 8 16d 4 10d x 1-1/2 1130 1295 1410 730 5, F30, R5
JUS38 -- -- 18 2-9/16 6-3/4 2 1 6 16d 4 16d 1290 1485 1615 1355 6, F15, R13
16 2-9/16 5-5/16 2 1-1/8 8 10d 4 10d x 1-1/2 930 1065 1160 725
16 2-9/16 5-5/16 2 1-1/8 8 16d 4 10d x 1-1/2 1105 1270 1380 725
HD36 HU36 14 2-9/16 4-3/4 2 1-1/8 8 16d 4 10d x 1-1/2 1130 1295 1410 730 HD38 HU38 14 2-9/16 6-3/4 2 1-1/8 12 16d 4 10d x 1-1/2 1690 1945 2115 730
JUS310 LUS310 18 2-9/16 9-1/8 2 1 8 16d 6 16d 1800 2070 2250 1980 6, F15, R13
16 2-9/16 8-7/8 2 1-1/8 14 10d 6 10d x 1-1/2 1625 1870 2030 108516 2-9/16 8-7/8 2 1-1/8 14 16d 6 10d x 1-1/2 1930 2220 2415 1085
HD38 HU38 14 2-9/16 6-3/4 2 1-1/8 12 16d 4 10d x 1-1/2 1690 1945 2115 730 HD310 HU310 14 2-9/16 7-7/16 2-1/2 1-1/8 14 16d 6 10d x 1-1/2 1975 2270 2470 1065
HDQ310IF HUCQ310-SDS 14 2-9/16 9 3 1-3/16 8 WS3 4 WS15 3340 3380 3380 1470 110
16 2-9/16 8-7/8 2 1-1/8 14 10d 6 10d x 1-1/2 1625 1870 2030 108516 2-9/16 8-7/8 2 1-1/8 14 16d 6 10d x 1-1/2 1930 2220 2415 1085
HD38 HU38 14 2-9/16 6-3/4 2 1-1/8 12 16d 4 10d x 1-1/2 1690 1945 2115 730 HD310 HU310 14 2-9/16 7-7/16 2-1/2 1-1/8 14 16d 6 10d x 1-1/2 1975 2270 2470 1065
HDQ310IF HUCQ310-SDS 14 2-9/16 9 3 1-3/16 8 WS3 4 WS15 3340 3380 3380 1470 110
HD312 HU312 14 2-9/16 9-5/16 2-1/2 1-1/8 16 16d 10 10d x 1-1/2 2255 2595 2820 1065 5, F30, R516 2-9/16 10-9/16 2 1-1/8 16 10d 6 10d x 1-1/2 1855 2135 2320 1085
16 2-9/16 10-9/16 2 1-1/8 16 16d 6 10d x 1-1/2 2210 2505 2505 1085 HD310 HU310 14 2-9/16 7-7/16 2-1/2 1-1/8 14 16d 6 10d x 1-1/2 1975 2270 2470 1065 5, F30, R5
HDQ310IF HUCQ310-SDS 14 2-9/16 9 3 1-3/16 8 WS3 4 WS15 3340 3380 3380 1470 110
HD312 HU312 14 2-9/16 9-5/16 2-1/2 1-1/8 16 16d 10 10d x 1-1/2 2255 2595 2820 1065 HD314 HU314 14 2-9/16 11-5/16 2-1/2 1-1/8 20 16d 10 10d x 1-1/2 2820 3245 3525 1065
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 3) Minimum nail embedment shall be 1-1/2˝ for 10d nails; 1-5/8˝ for 16d and N16C-GC nails. 4) 16d sinkers (9 gauge x 3-1/4˝ long) may be used at 0.84 of the table load where 16d commons are specified. 5) For JUS, HUS, and MUS hangers: Nails must be driven at a 30° to 45˚ angle through the joist or truss into the header to achieve the table loads. 6) WS15 Wood Screws are 1-1/4˝ x 1-1/2˝ long and are included with HDQ hangers. 7) WS3 Wood Screws are 1-1/4˝ x 3˝ long and are included with HDQ hangers.
5, F30, R5
2, F20,R12
2, F20,R12
2, F20,R12
5, F30, R5
2, F20,R12
2, F20,R12
2, F20,R12
2, F20,R12
2, F20,R12
5, F30, R5
6, F5,F15, D7, R13
5, F30, R5
5, F30,R5
5, F30,R5
CodeRef.
Allowable Loads (Lbs.)
DF-L / SP
Roof
3 x 12
SUH310 U310
3 x 14
SUH314 U314
3 x 8 SUH36 U36
SUH310 U310
3 x 10
3 x 4 SUH34 U34
3 x 6
SUH34 U34
SUH36 U36
(2) 2 x 14
SUH210-2 U210-2
(2) 2 x 16
USPStock No.
SteelGauge
(2) 2 x 12
SUH210-2 U210-2
Dimensions Fastener Schedule2,3,4,6,7
Header Joist
continued on next page
A
H
DW
1-800-328-5934 • www.USPconnectors.com
USP2173-111
Han
gers
1-800-328-5934 • www.USPconnectors.com 93
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Face Mount Hanger Charts continued
Floor Uplift1
Joist Size Ref. No. W H D A Qty Nail Qty Nail 100% 115% 125% 160%
16 2-9/16 10-9/16 2 1-1/8 16 10d 6 10d x 1-1/2 1855 2135 2320 1085
16 2-9/16 10-9/16 2 1-1/8 16 16d 6 10d x 1-1/2 2210 2505 2505 1085
HD312 HU312 14 2-9/16 9-5/16 2-1/2 1-1/8 16 16d 10 10d x 1-1/2 2255 2595 2820 1065 HD314 HU314 14 2-9/16 11-5/16 2-1/2 1-1/8 20 16d 10 10d x 1-1/2 2820 3245 3525 1065
HD316 HU316 14 2-9/16 13-5/16 2-1/2 1-1/8 24 16d 10 10d x 1-1/2 3385 3890 4230 1065 (2) 3 x 8 HD38-2 HU38-2 14 5-1/8 6-1/8 2-1/2 1-1/8 14 16d 6 10d 1975 2270 2470 1140
HD38-2 HU38-2 14 5-1/8 6-1/8 2-1/2 1-1/8 14 16d 6 10d 1975 2270 2470 1140
HD310-2 HU310-2 14 5-1/8 8 2-1/2 1-1/8 18 16d 10 10d 2540 2920 3175 1905
(2) 3 x 12 HD310-2 HU310-2 14 5-1/8 8 2-1/2 1-1/8 18 16d 10 10d 2540 2920 3175 1905
(2) 3 x 14 HD310-2 HU310-2 14 5-1/8 8 2-1/2 1-1/8 18 16d 10 10d 2540 2920 3175 1905
JUS26-3 LUS26-3 18 4-5/8 4-1/2 2 1 4 16d 4 16d 1015 1170 1220 1355 6, F5,
F15, D7, R13
16 4-5/8 5-1/4 2 1 8 10d 2 10d 930 1065 1160 37016 4-5/8 5-1/4 2 1 8 16d 2 10d 1105 1270 1380 370
HD26-3 HU26-3 14 4-5/8 4-3/8 2-1/2 1-1/8 12 16d 6 10d 1690 1945 2095 1140 5, F30, R5
JUS26-3 LUS26-3 18 4-5/8 4-1/2 2 1 4 16d 4 16d 1015 1170 1220 1355 JUS28-3 LUS28-3 18 4-5/8 6-3/8 2 1 6 16d 4 16d 1290 1485 1615 1355
16 4-5/8 5-1/4 2 1 8 10d 2 10d 930 1065 1160 370
16 4-5/8 5-1/4 2 1 8 16d 2 10d 1105 1270 1380 370 HD26-3 HU26-3 14 4-5/8 4-3/8 2-1/2 1-1/8 12 16d 6 10d 1690 1945 2095 1140
HD28-3 -- -- 14 4-5/8 6-3/8 2-1/2 1-1/8 12 16d 6 10d 1690 1945 2115 1140 JUS28-3 LUS28-3 18 4-5/8 6-3/8 2 1 6 16d 4 16d 1290 1485 1615 1355
JUS210-3 LUS210-3 18 4-5/8 8-3/8 2 1 8 16d 6 16d 1800 2070 2250 1980
16 4-5/8 8-3/8 2 1 14 10d 6 10d 1625 1870 2030 111516 4-5/8 8-3/8 2 1 14 16d 6 10d 1930 2220 2415 1115
HD28-3 -- -- 14 4-5/8 6-3/8 2-1/2 1-1/8 12 16d 6 10d 1690 1945 2115 1140 HD210-3 HU210-3 14 4-5/8 8-1/4 2-1/2 1-1/8 18 16d 10 10d 2540 2920 3175 1905
HDQ210-3IF HUCQ210-3-SDS 14 4-5/8 9 3 1-1/2 12 WS3 6 WS3 5015 5590 5590 2975 110
JUS210-3 LUS210-3 18 4-5/8 8-3/8 2 1 8 16d 6 16d 1800 2070 2250 1980 6, F5,
F15, D7, R13
16 4-5/8 8-3/8 2 1 14 10d 6 10d 1625 1870 2030 1115
16 4-5/8 8-3/8 2 1 14 16d 6 10d 1930 2220 2415 1115
HD210-3 HU210-3 14 4-5/8 8-1/4 2-1/2 1-1/8 18 16d 10 10d 2540 2920 3175 1905 5, F30, R5 HDQ210-3IF HUCQ210-3-SDS 14 4-5/8 9 3 1-1/2 12 WS3 6 WS3 5015 5590 5590 2975 110
HD212-3 HU212-3 14 4-5/8 10-1/4 2-1/2 1-1/8 22 16d 10 10d 3100 3565 3880 1905 5, F30, R5
JUS210-3 LUS210-3 18 4-5/8 8-3/8 2 1 8 16d 6 16d 1800 2070 2250 1980 6, F5,
F15, D7, R13
16 4-5/8 8-3/8 2 1 14 10d 6 10d 1625 1870 2030 1115
16 4-5/8 8-3/8 2 1 14 16d 6 10d 1930 2220 2415 1115 HD210-3 HU210-3 14 4-5/8 8-1/4 2-1/2 1-1/8 18 16d 10 10d 2540 2920 3175 1905 5, F30, R5
HDQ210-3IF HUCQ210-3-SDS 14 4-5/8 9 3 1-1/2 12 WS3 6 WS3 5015 5590 5590 2975 110
HD212-3 HU212-3 14 4-5/8 10-1/4 2-1/2 1-1/8 22 16d 10 10d 3100 3565 3880 1905 HD214-3 HU214-3 14 4-5/8 12-1/4 2-1/2 1-1/8 24 16d 10 10d 3385 3890 4230 1905
HD212-3 HU212-3 14 4-5/8 10-1/4 2-1/2 1-1/8 22 16d 10 10d 3100 3565 3880 1905 HD214-3 HU214-3 14 4-5/8 12-1/4 2-1/2 1-1/8 24 16d 10 10d 3385 3890 4230 1905
HD216-3 HU216-3 14 4-5/8 14-1/4 2-1/2 1-1/8 26 16d 12 10d 3665 4215 4570 2285
(4) 2 x 10 HD210-4 HU210-4 14 6-1/8 9 3-1/4 2 24 16d 6 10d 3385 3890 4230 1140 (4) 2 x 12 HD210-4 HU210-4 14 6-1/8 9 3-1/4 2 24 16d 6 10d 3385 3890 4230 1140
(4) 2 x 14 HD210-4 HU210-4 14 6-1/8 9 3-1/4 2 24 16d 6 10d 3385 3890 4230 1140
JUS44 LUS44 18 3-5/8 3-1/4 2 1 4 16d 2 16d 780 900 965 325 6, F5, R13
16 3-9/16 2-7/8 2 1-1/8 6 10d 2 10d 695 800 870 370
16 3-9/16 2-7/8 2 1-1/8 6 16d 2 10d 830 950 1035 370
HD44 HU44 14 3-9/16 3-5/16 2-1/2 1-1/8 4 16d 2 10d 565 650 705 320 5, F30, R5
JUS46 LUS46 18 3-5/8 5 2 1 4 16d 4 16d 1015 1170 1220 1355 6, F5,
F15, D7, R13
16 3-9/16 2-7/8 2 1-1/8 6 10d 2 10d 695 800 870 370
16 3-9/16 2-7/8 2 1-1/8 6 16d 2 10d 830 950 1035 370
16 3-9/16 4-13/16 2 1-1/8 8 10d 4 10d 930 1065 1160 740
16 3-9/16 4-13/16 2 1-1/8 8 16d 4 10d 1105 1270 1380 740
HUS46 HUS46 14 3-5/8 5 2 1 4 16d 4 16d 1030 1185 1290 1115 6, F18,
F15, D2, R13
HD46 HU46 14 3-9/16 4-15/16 2-1/2 1-1/8 12 16d 6 10d 1690 1945 2095 1140 5, F30, R5
2, F20,R12
2, F20,R12
5,F30,R5
6, F5,F15, D7, R13
2, F20,R12
2, F20,R12
5, F30,R5
6, F5,F15, D7, R13
5, F30,R5
5, R5
2, F20,R12
2, F20,R12
2, F20,R12
2, F20,R12
5,F30,R5
CodeRef.
Roof
Allowable Loads (Lbs.)
DF-L / SP
USPStock No.
SteelGauge
Dimensions Fastener Schedule2,3,4,6,7
Header
4 x 6
SUH44 U44
SUH46 U46
4 x 4 SUH44 U44
(3) 2 x 16
Joist
(3) 2 x 12 SUH210-3 U210-3
(2) 3 x 10
(3) 2 x 6 SUH26-3 U26-3
3 x 16
SUH314
(3) 2 x 14 SUH210-3 U210-3
(3) 2 x 8 SUH26-3 U26-3
SUH210-3 U210-3 (3) 2 x 10
U314
continued on next page
Floor Uplift1
Joist Size Ref. No. W H D A Qty Nail Qty Nail 100% 115% 125% 160%
JUS210-2 LUS210-2 18 3-1/8 9-1/8 2 1 8 16d 6 16d 1800 2070 2250 1980
JUS210-2GC -- -- 18 3-1/8 9-1/8 2 1 8 N16C-GC 6 N16C-GC 1800 2070 2250 198016 3-1/8 8-9/16 2 1-1/8 14 10d 6 10d 1625 1870 2030 1115
16 3-1/8 8-9/16 2 1-1/8 14 16d 6 10d 1930 2220 2415 1115
HUS210-2 HUS210-2 14 3-1/8 9-1/8 2 1 8 16d 8 16d 2065 2375 2580 2210
HD210-2 HU210-2 14 3-1/8 9 2-1/2 1-1/8 18 16d 10 10d 2540 2920 3175 1905 5, F30, R5
HDQ210-2IF HUCQ210-2-SDS 14 3-1/4 9 3 1-1/2 12 WS3 6 WS3 5015 5590 5590 2975 110
HUS212-2 HUS212-2 14 3-1/8 11-1/8 2 1 10 16d 10 16d 2580 2965 3225 3060
HD212-2 HU212-2 14 3-1/8 11 2-1/2 1-1/8 22 16d 10 10d 3100 3565 3880 1905 5, F30, R5
JUS210-2 LUS210-2 18 3-1/8 9-1/8 2 1 8 16d 6 16d 1800 2070 2250 1980
JUS214-2 -- -- 18 3-1/8 13-1/8 2 1 12 16d 6 16d 2345 2700 2935 1980 6, F1516 3-1/8 8-9/16 2 1-1/8 14 10d 6 10d 1625 1870 2030 1115
16 3-1/8 8-9/16 2 1-1/8 14 16d 6 10d 1930 2220 2415 1115
HD210-2 HU210-2 14 3-1/8 9 2-1/2 1-1/8 18 16d 10 10d 2540 2920 3175 1905 5, F30, R5 HDQ210-2IF HUCQ210-2-SDS 14 3-1/4 9 3 1-1/2 12 WS3 6 WS3 5015 5590 5590 2975 110
HUS212-2 HUS212-2 14 3-1/8 11-1/8 2 1 10 16d 10 16d 2580 2965 3225 3060
HD212-2 HU212-2 14 3-1/8 11 2-1/2 1-1/8 22 16d 10 10d 3100 3565 3880 1905 HD214-2 HU214-2 14 3-1/8 13 2-1/2 1-1/8 24 16d 10 10d 3385 3890 4230 1905
JUS214-2 -- -- 18 3-1/8 13-1/8 2 1 12 16d 6 16d 2345 2700 2935 1980 6, F15, R13 HD212-2 HU212-2 14 3-1/8 11 2-1/2 1-1/8 22 16d 10 10d 3100 3565 3880 1905
HD214-2 HU214-2 14 3-1/8 13 2-1/2 1-1/8 24 16d 10 10d 3385 3890 4230 1905
HD216-2 HU216-2 14 3-1/8 15 2-1/2 1-1/8 26 16d 12 10d 3665 4215 4570 228516 2-9/16 3-3/8 2 1-1/8 6 10d 2 10d x 1-1/2 695 800 850 360
16 2-9/16 3-3/8 2 1-1/8 6 16d 2 10d x 1-1/2 830 850 850 360 HD34 HU34 14 2-9/16 3 2 1-1/8 4 16d 2 10d x 1-1/2 565 650 705 290 5, F30, R5
JUS36 LUS36 18 2-9/16 5-5/16 2 1 4 16d 4 16d 1015 1170 1220 1355 6, F15, R13
16 2-9/16 3-3/8 2 1-1/8 6 10d 2 10d x 1-1/2 695 800 850 36016 2-9/16 3-3/8 2 1-1/8 6 16d 2 10d x 1-1/2 830 850 850 360
16 2-9/16 5-5/16 2 1-1/8 8 10d 4 10d x 1-1/2 930 1065 1160 72516 2-9/16 5-5/16 2 1-1/8 8 16d 4 10d x 1-1/2 1105 1270 1380 725
HD36 HU36 14 2-9/16 4-3/4 2 1-1/8 8 16d 4 10d x 1-1/2 1130 1295 1410 730 5, F30, R5
JUS38 -- -- 18 2-9/16 6-3/4 2 1 6 16d 4 16d 1290 1485 1615 1355 6, F15, R13
16 2-9/16 5-5/16 2 1-1/8 8 10d 4 10d x 1-1/2 930 1065 1160 725
16 2-9/16 5-5/16 2 1-1/8 8 16d 4 10d x 1-1/2 1105 1270 1380 725
HD36 HU36 14 2-9/16 4-3/4 2 1-1/8 8 16d 4 10d x 1-1/2 1130 1295 1410 730 HD38 HU38 14 2-9/16 6-3/4 2 1-1/8 12 16d 4 10d x 1-1/2 1690 1945 2115 730
JUS310 LUS310 18 2-9/16 9-1/8 2 1 8 16d 6 16d 1800 2070 2250 1980 6, F15, R13
16 2-9/16 8-7/8 2 1-1/8 14 10d 6 10d x 1-1/2 1625 1870 2030 108516 2-9/16 8-7/8 2 1-1/8 14 16d 6 10d x 1-1/2 1930 2220 2415 1085
HD38 HU38 14 2-9/16 6-3/4 2 1-1/8 12 16d 4 10d x 1-1/2 1690 1945 2115 730 HD310 HU310 14 2-9/16 7-7/16 2-1/2 1-1/8 14 16d 6 10d x 1-1/2 1975 2270 2470 1065
HDQ310IF HUCQ310-SDS 14 2-9/16 9 3 1-3/16 8 WS3 4 WS15 3340 3380 3380 1470 110
16 2-9/16 8-7/8 2 1-1/8 14 10d 6 10d x 1-1/2 1625 1870 2030 108516 2-9/16 8-7/8 2 1-1/8 14 16d 6 10d x 1-1/2 1930 2220 2415 1085
HD38 HU38 14 2-9/16 6-3/4 2 1-1/8 12 16d 4 10d x 1-1/2 1690 1945 2115 730 HD310 HU310 14 2-9/16 7-7/16 2-1/2 1-1/8 14 16d 6 10d x 1-1/2 1975 2270 2470 1065
HDQ310IF HUCQ310-SDS 14 2-9/16 9 3 1-3/16 8 WS3 4 WS15 3340 3380 3380 1470 110
HD312 HU312 14 2-9/16 9-5/16 2-1/2 1-1/8 16 16d 10 10d x 1-1/2 2255 2595 2820 1065 5, F30, R516 2-9/16 10-9/16 2 1-1/8 16 10d 6 10d x 1-1/2 1855 2135 2320 1085
16 2-9/16 10-9/16 2 1-1/8 16 16d 6 10d x 1-1/2 2210 2505 2505 1085 HD310 HU310 14 2-9/16 7-7/16 2-1/2 1-1/8 14 16d 6 10d x 1-1/2 1975 2270 2470 1065 5, F30, R5
HDQ310IF HUCQ310-SDS 14 2-9/16 9 3 1-3/16 8 WS3 4 WS15 3340 3380 3380 1470 110
HD312 HU312 14 2-9/16 9-5/16 2-1/2 1-1/8 16 16d 10 10d x 1-1/2 2255 2595 2820 1065 HD314 HU314 14 2-9/16 11-5/16 2-1/2 1-1/8 20 16d 10 10d x 1-1/2 2820 3245 3525 1065
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 3) Minimum nail embedment shall be 1-1/2˝ for 10d nails; 1-5/8˝ for 16d and N16C-GC nails. 4) 16d sinkers (9 gauge x 3-1/4˝ long) may be used at 0.84 of the table load where 16d commons are specified. 5) For JUS, HUS, and MUS hangers: Nails must be driven at a 30° to 45˚ angle through the joist or truss into the header to achieve the table loads. 6) WS15 Wood Screws are 1-1/4˝ x 1-1/2˝ long and are included with HDQ hangers. 7) WS3 Wood Screws are 1-1/4˝ x 3˝ long and are included with HDQ hangers.
Han
gers
1-800-328-5934 • www.USPconnectors.com94
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Face Mount Hanger Charts continued
Floor Uplift1
Joist Size Ref. No. W H D A Qty Nail Qty Nail 100% 115% 125% 160%
JUS46 LUS46 18 3-5/8 5 2 1 4 16d 4 16d 1015 1170 1220 1355
JUS48 LUS48 18 3-5/8 6-7/8 2 1 6 16d 4 16d 1290 1485 1615 1355
16 3-9/16 4-13/16 2 1-1/8 8 10d 4 10d 930 1065 1160 740
16 3-9/16 4-13/16 2 1-1/8 8 16d 4 10d 1105 1270 1380 740
HUS46 HUS46 14 3-5/8 5 2 1 4 16d 4 16d 1030 1185 1290 1115
HUS48 HUS48 14 3-5/8 7 2 1 6 16d 6 16d 1550 1780 1935 1810
HD46 HU46 14 3-9/16 4-15/16 2-1/2 1-1/8 12 16d 6 10d 1690 1945 2095 1140
HD48 HU48 14 3-9/16 6-7/8 2-1/2 1-1/8 14 16d 6 10d 1975 2270 2470 1140
JUS48 LUS48 18 3-5/8 6-7/8 2 1 6 16d 4 16d 1290 1485 1615 1355
JUS410 LUS410 18 3-5/8 8-7/8 2 1 8 16d 6 16d 1800 2070 2250 1980
16 3-9/16 8-3/8 2 1-1/8 14 10d 6 10d 1625 1870 2030 1115
16 3-9/16 8-3/8 2 1-1/8 14 16d 6 10d 1930 2220 2415 1115
HUS48 HUS48 14 3-5/8 7 2 1 6 16d 6 16d 1550 1780 1935 1810 6, F18,
F15, D2, R13
HD48 HU48 14 3-9/16 6-7/8 2-1/2 1-1/8 14 16d 6 10d 1975 2270 2470 1140 5, F30, R5
HUS410 HUS410 14 3-5/8 8-7/8 2 1 8 16d 8 16d 2065 2375 2580 2210 6, F18,
F15, D2, R13
HD410 HU410 14 3-9/16 8-13/16 2-1/2 1-1/8 18 16d 10 10d 2540 2920 3175 1905 5, F30, R5
HDQ410IF HUCQ410-SDS 14 3-9/16 9 3 1-1/2 12 WS3 6 WS3 5015 5590 5590 2975 110
JUS410 LUS410 18 3-5/8 8-7/8 2 1 8 16d 6 16d 1800 2070 2250 1980 6, F5,
F15, D7, R13
16 3-9/16 8-3/8 2 1-1/8 14 10d 6 10d 1625 1870 2030 1115
16 3-9/16 8-3/8 2 1-1/8 14 16d 6 10d 1930 2220 2415 1115
HD48 HU48 14 3-9/16 6-7/8 2-1/2 1-1/8 14 16d 6 10d 1975 2270 2470 1140 5, F30, R5
HUS410 HUS410 14 3-5/8 8-7/8 2 1 8 16d 8 16d 2065 2375 2580 2210 6, F18,
F15, D2, R13
HD410 HU410 14 3-9/16 8-13/16 2-1/2 1-1/8 18 16d 10 10d 2540 2920 3175 1905 5, F30, R5
HDQ410IF HUCQ410-SDS 14 3-9/16 9 3 1-1/2 12 WS3 6 WS3 5015 5590 5590 2975 110
HUS412 HUS412 14 3-5/8 10-7/8 2 1 10 16d 10 16d 2580 2965 3225 3060 6, F18,
F15, D2, R13
HDQ412IF HUCQ412-SDS 14 3-9/16 11 3 1-1/2 14 WS3 6 WS3 5590 5590 5590 2975 110
HD412 HU412 14 3-9/16 10-13/16 2-1/2 1-1/8 22 16d 10 10d 3100 3565 3880 1905 5, F30, R5
JUS414 LUS414 18 3-5/8 12-7/8 2 1 12 16d 6 16d 2345 2700 2935 1980 6, F15, R13
16 3-9/16 10-1/16 2 1-1/8 16 10d 6 10d 1855 2135 2320 1115
16 3-9/16 10-1/16 2 1-1/8 16 16d 6 10d 2210 2540 2760 1115
HD410 HU410 14 3-9/16 8-13/16 2-1/2 1-1/8 18 16d 10 10d 2540 2920 3175 1905 5, F30, R5
HDQ410IF HUCQ410-SDS 14 3-9/16 9 3 1-1/2 12 WS3 6 WS3 5015 5590 5590 2975 110
HUS412 HUS412 14 3-5/8 10-7/8 2 1 10 16d 10 16d 2580 2965 3225 3060 6, F18,
F15, D2, R13
HDQ412IF HUCQ412-SDS 14 3-9/16 11 3 1-1/2 14 WS3 6 WS3 5590 5590 5590 2975 110
HD412 HU412 14 3-9/16 10-13/16 2-1/2 1-1/8 22 16d 10 10d 3100 3565 3880 1905
HD414 HU414 14 3-9/16 12-13/16 2-1/2 1-1/8 24 16d 10 10d 3385 3890 4230 1905
JUS414 LUS414 18 3-5/8 12-7/8 2 1 12 16d 6 16d 2345 2700 2935 1980 6, F15, R13
16 3-9/16 10-1/16 2 1-1/8 16 10d 6 10d 1855 2135 2320 111516 3-9/16 10-1/16 2 1-1/8 16 16d 6 10d 2210 2540 2760 1115
HD412 HU412 14 3-9/16 10-13/16 2-1/2 1-1/8 22 16d 10 10d 3100 3565 3880 1905 5, F30, R5 HDQ412IF HUCQ412-SDS 14 3-9/16 11 3 1-1/2 14 WS3 6 WS3 5590 5590 5590 2975 110
HD414 HU414 14 3-9/16 12-13/16 2-1/2 1-1/8 24 16d 10 10d 3385 3890 4230 1905
HD416 HU416 14 3-9/16 14-13/16 2-1/2 1-1/8 26 16d 12 10d 3665 4215 4570 2285 HD414 HU414 14 3-9/16 12-13/16 2-1/2 1-1/8 24 16d 10 10d 3385 3890 4230 1905
HD416 HU416 14 3-9/16 14-13/16 2-1/2 1-1/8 26 16d 12 10d 3665 4215 4570 2285 HD418 -- -- 14 3-9/16 16-1/2 2-1/2 1-1/4 28 16d 8 10d 3950 4540 4570 1425
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 3) Minimum nail embedment shall be 1-1/2˝ for 10d nails and 1-5/8˝ for 16d nails. 4) 16d sinkers (9 gauge x 3-1/4˝ long) may be used at 0.84 of the table load where 16d commons are specified. 5) WS15 Wood Screws are 1-1/4˝ x 1-1/2˝ long and are included with HDQ hangers. 6) WS3 Wood Screws are 1-1/4˝ x 3˝ long and are included with HDQ hangers.
6, F5,F15, D7, R13
5, F30,R5
5,F30,R5
6, F18,F15, D2, R13
5, F30,R5
2, F20,R12
6, F5,F15, D7, R13
2, F20,R12
2, F20,R12
2, F20,R12
2, F20,R12
CodeRef.
Allowable Loads (Lbs.)
DF-L / SP
Roof
4 x 16
SUH414 U414
4 x 18
Header Joist
USPStock No.
SteelGauge
Dimensions Fastener Schedule2,3,4,5,6
4 x 12
SUH410 U410
4 x 14
SUH414 U414
4 x 8
SUH46 U46
SUH410 U410
4 x 10
continued on next page1-800-328-5934 • www.USPconnectors.com
USP2173-111
Han
gers
1-800-328-5934 • www.USPconnectors.com 95
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Floor Uplift1
Joist Size Ref. No. W H D A Qty Nail Qty Nail 100% 115% 125% 160%16 5-1/2 5 2 1 8 10d 4 10d 930 1065 1160 740
16 5-1/2 5 2 1 8 16d 4 10d 1105 1270 1380 740
HD66 HU66 14 5-1/2 3-15/16 2-1/2 1-1/8 12 16d 6 10d 1690 1945 2095 1140 5, F30, R516 5-1/2 5 2 1 8 10d 4 10d 930 1065 1160 740
16 5-1/2 5 2 1 8 16d 4 10d 1105 1270 1380 740
HD66 HU66 14 5-1/2 3-15/16 2-1/2 1-1/8 12 16d 6 10d 1690 1945 2095 1140
HD68 HU68 14 5-1/2 5-15/16 2-1/2 1-1/8 14 16d 6 10d 1975 2270 2470 1140
16 5-1/2 9 2 1 14 10d 6 10d 1625 1870 2030 1115
16 5-1/2 9 2 1 14 16d 6 10d 1930 2220 2415 1115 HD68 HU68 14 5-1/2 5-15/16 2-1/2 1-1/8 14 16d 6 10d 1975 2270 2470 1140
HD610 HU610 14 5-1/2 7-13/16 2-1/2 1-1/8 18 16d 10 10d 2540 2920 3175 1905 HDQ610IF HUCQ610-SDS 14 5-1/2 9 3 1-1/2 12 WS3 6 WS3 5015 5590 5590 2975 110
16 5-1/2 9 2 1 14 10d 6 10d 1625 1870 2030 1115
16 5-1/2 9 2 1 14 16d 6 10d 1930 2220 2415 1115 HD610 HU610 14 5-1/2 7-13/16 2-1/2 1-1/8 18 16d 10 10d 2540 2920 3175 1905 5, F30, R5
HDQ610IF HUCQ610-SDS 14 5-1/2 9 3 1-1/2 12 WS3 6 WS3 5015 5590 5590 2975 110 HD612 HU612 14 5-1/2 9-13/16 2-1/2 1-1/8 22 16d 10 10d 3100 3565 3880 1905 5, F30, R5
HDQ612IF HUCQ612-SDS 14 5-1/2 11 3 1-1/2 14 WS3 6 WS3 5590 5590 5590 2975 110
HD610 HU610 14 5-1/2 7-13/16 2-1/2 1-1/8 18 16d 10 10d 2540 2920 3175 1905 5, F30, R5 HDQ610IF HUCQ610-SDS 14 5-1/2 9 3 1-1/2 12 WS3 6 WS3 5015 5590 5590 2975 110
HD612 HU612 14 5-1/2 9-13/16 2-1/2 1-1/8 22 16d 10 10d 3100 3565 3880 1905 5, F30, R5 HDQ612IF HUCQ612-SDS 14 5-1/2 11 3 1-1/2 14 WS3 6 WS3 5590 5590 5590 2975 110
HD614 HU614 14 5-1/2 11-13/16 2-1/2 1-1/8 24 16d 10 10d 3385 3890 4230 1905
HD612 HU612 14 5-1/2 9-13/16 2-1/2 1-1/8 22 16d 10 10d 3100 3565 3880 1905 HDQ612IF HUCQ612-SDS 14 5-1/2 11 3 1-1/2 14 WS3 6 WS3 5590 5590 5590 2975 110
HD614 HU614 14 5-1/2 11-13/16 2-1/2 1-1/8 24 16d 10 10d 3385 3890 4230 1905 HD616 HU616 14 5-1/2 13-13/16 2-1/2 1-1/8 26 16d 12 10d 3665 4215 4570 2285
HD614 HU614 14 5-1/2 11-13/16 2-1/2 1-1/8 24 16d 10 10d 3385 3890 4230 1905
HD616 HU616 14 5-1/2 13-13/16 2-1/2 1-1/8 26 16d 12 10d 3665 4215 4570 2285 8 x 6 HD86 -- -- 14 7-1/2 5-1/8 2-1/2 1-1/2 10 16d 4 16d 1410 1620 1740 900
8 x 8 HD88 HU88 14 7-1/2 6-5/8 2-1/2 1-1/2 14 16d 6 16d 1975 2270 2470 1355 8 x 10 HD810 HU810 14 7-1/2 8-3/8 2-1/2 1-1/2 18 16d 8 16d 2540 2920 3175 1805
8 x 12 HD812 HU812 14 7-1/2 10-1/8 2-1/2 1-1/2 22 16d 8 16d 3100 3565 3880 1805
8 x 14 HD814 HU814 14 7-1/2 11-7/8 2-1/2 1-1/2 24 16d 12 16d 3385 3890 4230 2705
8 x 16 HD816 HU816 14 7-1/2 13-5/8 2-1/2 1-1/2 26 16d 12 16d 3665 4215 4465 2705
16 2 3-1/16 2 1-1/8 4 10d 2 10d x 1-1/2 465 535 580 360
16 2 3-1/16 2 1-1/8 4 16d 2 10d x 1-1/2 550 635 690 36016 2 4-15/16 2 1-3/16 6 10d 4 10d x 1-1/2 695 800 870 725
16 2 4-15/16 2 1-3/16 6 16d 4 10d x 1-1/2 830 950 1035 725
16 2 6-7/16 2 1-1/8 8 10d 6 10d x 1-1/2 930 1065 1160 80016 2 6-7/16 2 1-1/8 8 16d 6 10d x 1-1/2 1105 1270 1380 800
16 2 7-13/16 2 1-1/8 10 10d 6 10d x 1-1/2 1160 1335 1450 108516 2 7-13/16 2 1-1/8 10 16d 6 10d x 1-1/2 1380 1585 1725 1085
16 2 9-13/16 2 1-1/8 12 10d 6 10d x 1-1/2 1390 1600 1740 108516 2 9-13/16 2 1-1/8 12 16d 6 10d x 1-1/2 1655 1905 2070 1085
16 4 2-11/16 2 1-1/8 6 10d 2 16d 695 800 870 44016 4 2-11/16 2 1-1/8 6 16d 2 16d 830 950 1035 440
16 4 4-11/16 2 1-1/8 8 10d 4 16d 930 1065 1160 885
16 4 4-11/16 2 1-1/8 8 16d 4 16d 1105 1270 1380 885
16 4 8-3/16 2 2 14 10d 6 16d 1625 1870 2030 1325
16 4 8-3/16 2 2 14 16d 6 16d 1930 2220 2415 1325
16 6 5 2 1 8 10d 4 16d 930 1065 1160 88516 6 5 2 1 8 16d 4 16d 1105 1270 1380 885
16 6 9 2 1 14 10d 6 16d 1625 1870 2030 132516 6 9 2 1 14 16d 6 16d 1930 2220 2415 1325
3-1/8 x 10-1/2 - 19-1/2 HD32105 HU3.25/10.5 14 3-1/4 9-15/16 2-1/2 1-1/8 22 16d 10 10d 3100 3565 3880 1905
3-1/8 x 12 - 21 HD3212 HU3.25/12 14 3-1/4 11-7/8 2-1/2 1-1/8 24 16d 10 10d 3385 3890 4230 1905
5-1/8 x 10-1/2 - 19-1/2 HD5112 HU5.125/12 14 5-1/4 9-15/16 2-1/2 1-1/8 22 16d 10 10d 3100 3565 3880 1905
5-1/8 x 14-1/2 - 21 HD51135 HU5.125/13.5 14 5-1/4 12-15/16 2-1/2 1-1/8 26 16d 12 10d 3665 4215 4570 2285
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 3) Minimum nail embedment shall be 1-1/2˝ for 10d nails and 1-5/8˝ for 16d nails. 4) 16d sinkers (9 gauge x 3-1/4˝ long) may be used at 0.84 of the table load where 16d commons are specified. 5) WS15 Wood Screws are 1-1/4˝ x 1-1/2˝ long and are included with HDQ hangers. 6) WS3 Wood Screws are 1-1/4˝ x 3˝ long and are included with HDQ hangers.
5, F30, R5
5, F30, R5
5,F30,R5
5, F30, R5
5, R5
2, F20,R12
2, F20,R12
130
5, F30, R5
CodeRef.
Rough Lumber Sizes
USPStock No.
SteelGauge
DF-L / SP
Roof
Dimensions Fastener Schedule2,3,4
Header Joist
Glulam Sizes
2, F20,R12
2, F20,R12
2, F20,R12
2, F20,R12
6 x 10 SUH610R U610R
6 x 8 SUH66R
Allowable Loads (Lbs.)
4 x 10 SUH410R U410R
2 x 10 - 12 - 14 SUH210R LU210R-18, U210R
2 x 14 - 16 SUH214R
U66R
4 x 6 SUH44R U44R
4 x 8 SUH46R U46R
-- --
2 x 6 - 8 SUH26R LU26R-18, U26R
2 x 8 - 10 SUH28R LU28R-18
2 x 4 SUH24R LU24R-18, U24R
6 x 18
SUH66 U66
6 x 8
SUH66 U66
6 x 6
6 x 16
SUH610 U610
SUH610 U610
6 x 10
6 x 12
6 x 14
Face Mount Hanger Charts continued
A
H
DW
Floor Uplift1
Joist Size Ref. No. W H D A Qty Nail Qty Nail 100% 115% 125% 160%
JUS46 LUS46 18 3-5/8 5 2 1 4 16d 4 16d 1015 1170 1220 1355
JUS48 LUS48 18 3-5/8 6-7/8 2 1 6 16d 4 16d 1290 1485 1615 1355
16 3-9/16 4-13/16 2 1-1/8 8 10d 4 10d 930 1065 1160 740
16 3-9/16 4-13/16 2 1-1/8 8 16d 4 10d 1105 1270 1380 740
HUS46 HUS46 14 3-5/8 5 2 1 4 16d 4 16d 1030 1185 1290 1115
HUS48 HUS48 14 3-5/8 7 2 1 6 16d 6 16d 1550 1780 1935 1810
HD46 HU46 14 3-9/16 4-15/16 2-1/2 1-1/8 12 16d 6 10d 1690 1945 2095 1140
HD48 HU48 14 3-9/16 6-7/8 2-1/2 1-1/8 14 16d 6 10d 1975 2270 2470 1140
JUS48 LUS48 18 3-5/8 6-7/8 2 1 6 16d 4 16d 1290 1485 1615 1355
JUS410 LUS410 18 3-5/8 8-7/8 2 1 8 16d 6 16d 1800 2070 2250 1980
16 3-9/16 8-3/8 2 1-1/8 14 10d 6 10d 1625 1870 2030 1115
16 3-9/16 8-3/8 2 1-1/8 14 16d 6 10d 1930 2220 2415 1115
HUS48 HUS48 14 3-5/8 7 2 1 6 16d 6 16d 1550 1780 1935 1810
HD48 HU48 14 3-9/16 6-7/8 2-1/2 1-1/8 14 16d 6 10d 1975 2270 2470 1140 5, F30, R5
HUS410 HUS410 14 3-5/8 8-7/8 2 1 8 16d 8 16d 2065 2375 2580 2210
HD410 HU410 14 3-9/16 8-13/16 2-1/2 1-1/8 18 16d 10 10d 2540 2920 3175 1905 5, F30, R5
HDQ410IF HUCQ410-SDS 14 3-9/16 9 3 1-1/2 12 WS3 6 WS3 5015 5590 5590 2975 110
JUS410 LUS410 18 3-5/8 8-7/8 2 1 8 16d 6 16d 1800 2070 2250 1980
16 3-9/16 8-3/8 2 1-1/8 14 10d 6 10d 1625 1870 2030 1115
16 3-9/16 8-3/8 2 1-1/8 14 16d 6 10d 1930 2220 2415 1115
HD48 HU48 14 3-9/16 6-7/8 2-1/2 1-1/8 14 16d 6 10d 1975 2270 2470 1140 5, F30, R5
HUS410 HUS410 14 3-5/8 8-7/8 2 1 8 16d 8 16d 2065 2375 2580 2210
HD410 HU410 14 3-9/16 8-13/16 2-1/2 1-1/8 18 16d 10 10d 2540 2920 3175 1905 5, F30, R5
HDQ410IF HUCQ410-SDS 14 3-9/16 9 3 1-1/2 12 WS3 6 WS3 5015 5590 5590 2975 110
HUS412 HUS412 14 3-5/8 10-7/8 2 1 10 16d 10 16d 2580 2965 3225 3060
HDQ412IF HUCQ412-SDS 14 3-9/16 11 3 1-1/2 14 WS3 6 WS3 5590 5590 5590 2975 110
HD412 HU412 14 3-9/16 10-13/16 2-1/2 1-1/8 22 16d 10 10d 3100 3565 3880 1905 5, F30, R5
JUS414 LUS414 18 3-5/8 12-7/8 2 1 12 16d 6 16d 2345 2700 2935 1980 6, F15, R13
16 3-9/16 10-1/16 2 1-1/8 16 10d 6 10d 1855 2135 2320 1115
16 3-9/16 10-1/16 2 1-1/8 16 16d 6 10d 2210 2540 2760 1115
HD410 HU410 14 3-9/16 8-13/16 2-1/2 1-1/8 18 16d 10 10d 2540 2920 3175 1905 5, F30, R5
HDQ410IF HUCQ410-SDS 14 3-9/16 9 3 1-1/2 12 WS3 6 WS3 5015 5590 5590 2975 110
HUS412 HUS412 14 3-5/8 10-7/8 2 1 10 16d 10 16d 2580 2965 3225 3060
HDQ412IF HUCQ412-SDS 14 3-9/16 11 3 1-1/2 14 WS3 6 WS3 5590 5590 5590 2975 110
HD412 HU412 14 3-9/16 10-13/16 2-1/2 1-1/8 22 16d 10 10d 3100 3565 3880 1905
HD414 HU414 14 3-9/16 12-13/16 2-1/2 1-1/8 24 16d 10 10d 3385 3890 4230 1905
JUS414 LUS414 18 3-5/8 12-7/8 2 1 12 16d 6 16d 2345 2700 2935 1980 6, F15, R13
16 3-9/16 10-1/16 2 1-1/8 16 10d 6 10d 1855 2135 2320 111516 3-9/16 10-1/16 2 1-1/8 16 16d 6 10d 2210 2540 2760 1115
HD412 HU412 14 3-9/16 10-13/16 2-1/2 1-1/8 22 16d 10 10d 3100 3565 3880 1905 5, F30, R5 HDQ412IF HUCQ412-SDS 14 3-9/16 11 3 1-1/2 14 WS3 6 WS3 5590 5590 5590 2975 110
HD414 HU414 14 3-9/16 12-13/16 2-1/2 1-1/8 24 16d 10 10d 3385 3890 4230 1905
HD416 HU416 14 3-9/16 14-13/16 2-1/2 1-1/8 26 16d 12 10d 3665 4215 4570 2285 HD414 HU414 14 3-9/16 12-13/16 2-1/2 1-1/8 24 16d 10 10d 3385 3890 4230 1905
HD416 HU416 14 3-9/16 14-13/16 2-1/2 1-1/8 26 16d 12 10d 3665 4215 4570 2285 HD418 -- -- 14 3-9/16 16-1/2 2-1/2 1-1/4 28 16d 8 10d 3950 4540 4570 1425
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 3) Minimum nail embedment shall be 1-1/2˝ for 10d nails and 1-5/8˝ for 16d nails. 4) 16d sinkers (9 gauge x 3-1/4˝ long) may be used at 0.84 of the table load where 16d commons are specified. 5) WS15 Wood Screws are 1-1/4˝ x 1-1/2˝ long and are included with HDQ hangers. 6) WS3 Wood Screws are 1-1/4˝ x 3˝ long and are included with HDQ hangers.
Han
gers
1-800-328-5934 • www.USPconnectors.com96
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Heavy-Duty Top Mount Hangers – HDO series
1-800-328-5934 • www.USPconnectors.com
H
DW
1 1/4˝
TF
HDO28-2
Typical HDO skewedoption installation
Typical HDO410IFinverted flange installation
Specialty Options Chart – refer to Specialty Options pages 194-195 for additional details.
Option Skewed1,3 Sloped Seat2,3 Sloped / Skewed1,2,3Inverted Flange
1) Skewed hangers with skews greater than 15° may have all joist nailing on outside flange. 2) Sloped or sloped / skewed hangers with slopes greater than 15° may have additional joist nails. 3) All sloped, skewed, or combinations require bevel cut on joist in all applications and web stiffeners with I-joists.
Range
Add IFto product number.
Ex. HDO610IF
AllowableLoads
Ordering
100% of table load.75% of uplift loadon skews greater
than 15˚.
100% of table load
80% of table load.75% of uplift loadon skews greater
than 15˚.
100% of table load.65% of table load whennailing into the supportmembers end grain.
Add SK, angle required,and right (R) or left (L),
to product number.Ex. HDO210-SK45R
Not available inwidths less than 3-1/8˝
1˚ to 67-1/2˚ when width is 1-3/4˝ or less.1˚ to 50˚ on all others.
1˚ to 45˚ See Sloped Seat and Skewed
See Sloped Seat and Skewed.Ex. HDO210-SK45RSL30D
Add SL,slope required,and up (U) or down (D),
to product number.Ex. HDO210-SL30D
Primarily used to hang joists or headers in medium load conditions. These hangers provide higher load values with less nailing.
Materials: 12 gaugeFinish: G90 galvanizing
Options: All nominal lumber sizes are available for rough/fullsize lumber. See Specialty Options Chart.
Codes: ESR-1781, FL13285, L.A. City RR 25843
Installation:• Use all specified fasteners. See Product Notes, page 11.• Check top flange dimensions to ensure compatibility withheader widths.• Do not use for welded or nailer applications.Reference Specialty Options chart below for hangeroptions.
Installation:• Use all specified fasteners. See Product Notes, page 11.• NA20D nails are supplied with KHW hangers.• For welded installations see page 198.• KHW models are not recommended for use with LVL, PSL,or LSL members.
USP2173-111
Han
gers
1-800-328-5934 • www.USPconnectors.com 97
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
2 1/2˝
D
H
L
KHW46
Typical KHW46installation
Typical SW210installation
SW210
2 1/2˝ L
H
DW
Welded Top Flange Hangers – KHW, SW, & SWH series
Header Joist DF-L / SP S-P-F
SW 2X (2) 10d x 1-1/2 (2) 10d x 1-1/2 1635 11152X (2) 10d x 1-1/2 (2) 10d 2600 1770
3X (2) 16d x 2-1/2 (2) 10d 3350 2280
KHW 3X (4) 16d x 2-1/2 (2) 10d 5180 3525
1) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 2) 16d x 2-1/2 nails are 8 gauge (0.162˝ diameter) by 2-1/2˝ long. 3) Minimum nail embedment shall be 1-1/2˝ for 10d nails. 4) Listed loads shall not be increased.
Allowable Loads (Lbs.)4
SWH
USPStock No.
NailerSize
Fastener Schedule1,2,3
Nailer Installation Chart – chart represents maximum allowableloads for hangers used on wood nailers. Reference page 115.
Option Skewed1 Sloped Seat2 Sloped / Skewed 1,2 Sloped Top Flange3Saddle Ridge
1) Skewed hangers with skews greater than 15° may have all joist nailing on outside flange. 2) Sloped or sloped / skewed hangers with slopes greater than 15° may have additional joist nails. 3) Sloped top flanges with greater than 15° may have additional header nails.
Top Flange Offset
Add OS,andright (R)or left (L),to product number.Ex. SW212-OSL
% of table load:60%75%85%
100% of table loadper side
Hanger Width3-1/2˝ or less
3-9/16˝ to 5-1/2˝5-9/16˝ to 7-1/2˝
100% of table load
Add SK, angle required,and right (R)or left (L),
to product number.Ex. SW212-SK45R
Add SL,slope required,and up (U)or down (D),
to product number.Ex. SW212-SL30D
See Sloped Seatand Skewed.
Ex. SW212-SK45RSL30D
Add SF,angle required,and right (R)or left (L),
to product number.Ex. SW212-SF30L
Add SA, and saddlewidth required
to product number.Ex. SW212-SA=5-1/2˝
Add DA,angle required
to product number.Ex. SW212-DA30
100% of table load 100% of table loadReduce allowabletable loads using
straight-line interpolation
1˚ to 45˚ 0° to 35° -- -- 0° to 45° -- --See Sloped Seat
and SkewedRange
AllowableLoads
Ordering
1˚ to 84˚
100% of table load
Specialty Options Chart – refer to Specialty Options pages 194, 196 to 197 for additional details.
2 1/2˝
L
H
DW
SWH410
SW – Light-duty hanger.
SWH – Medium-duty hanger.
KHW – Heavy-duty hanger installs with NA20D nails for higherload capacities.
Materials: SW top flange - 12 gauge; stirrup - 12 gauge;SWH top flange - 7 gauge; stirrup - 12 gauge;KHW top flange - 3 gauge; stirrup - 10 gauge.
Finish: USP primerOptions: All nominal lumber sizes are available
for rough/full size lumber. See Specialty Options below.
Codes: ESR-2104, FL820, L.A. City RR 25745
These top mount hangers are designed for supporting floor joists or 2x purlins.The top mount style allows builders to drop in joists or purlins quickly.
Materials: 18 gaugeFinish: G90 galvanizingCodes: ESR-1280, FL11664, LA City RR 25749
Installation:• Use all specified fasteners. See Product Notes, page 11.
Light Gauge Purlin Hangers – HL seriesTF
H
DW
HL210
Han
gers
1-800-328-5934 • www.USPconnectors.com98
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Top Mount Hanger Charts
Floor Uplift1,2
Ref. No. W H D L TF Top Face Type Qty Type 100% 115% 125% 160%
2 x 4 HDO24 HU24TF 12 1-9/16 3-7/16 2-1/4 -- -- 2-1/2 4 2 16d 2 10d x 1-1/2 2170 2170 2170 315 5, F30, R5
HL26 JB26, LB26 18 1-9/16 5-3/8 1-1/2 -- -- 1-5/16 2 4 16d 2 prongs 1270 1270 1270 -- -- 2, F20, R12
SW26 W26 12 1-9/16 5-3/8 2-1/2 6-1/2 2-1/2 2 -- -- 10d 2 10d x 1-1/2 2315 2315 2315 -- -- 8, F14, R9
HDO26 HU26TF 12 1-9/16 5-3/8 2-1/4 -- -- 2-1/2 4 6 16d 4 10d x 1-1/2 2590 2615 2615 770 5, F30, R5
HL28 JB28, LB28 18 1-9/16 7-5/16 1-3/4 -- -- 1-5/16 2 4 16d 2 prongs 1590 1590 1590 -- -- 2, F20, R12
SW28 W28 12 1-9/16 7-1/8 2-1/2 6-1/2 2-1/2 2 -- -- 10d 2 10d x 1-1/2 2315 2315 2315 -- -- 8, F14, R9
HDO28 HU28TF 12 1-9/16 7-1/8 2-1/4 -- -- 2-1/2 4 6 16d 4 10d x 1-1/2 2590 2660 2710 755 5, F30, R5
HL210 JB210, LB210 18 1-9/16 9-5/16 2 -- -- 1-5/16 2 4 16d 2 prongs 1590 1590 1590 -- -- 2, F20, R12
SW210 W210 12 1-9/16 9-1/8 2-1/2 6-1/2 2-1/2 2 -- -- 10d 2 10d x 1-1/2 2315 2315 2315 -- -- 8, F14, R9
HDO210 HU210TF 12 1-9/16 9-1/8 2-1/4 -- -- 2-1/2 4 8 16d 4 10d x 1-1/2 2590 2660 2710 725 5, F30, R5
HL212 JB212, LB212 18 1-9/16 11-1/4 2-1/8 -- -- 1-5/16 2 4 16d 2 prongs 1590 1590 1590 -- -- 2, F20, R12
SW212 W212 12 1-9/16 11-1/8 2-1/2 6-1/2 2-1/2 2 -- -- 10d 2 10d x 1-1/2 2315 2315 2315 -- -- 8, F14, R9
HDO212 HU212TF 12 1-9/16 11 2-1/4 -- -- 2-1/2 4 10 16d 6 10d x 1-1/2 2355 2355 2355 1150 5, F30, R5
HL214 JB214, LB214 18 1-9/16 13-1/8 2 -- -- 2-1/2 2 6 16d 2 10d x 1-1/2 1590 1590 1590 360 2, F20, R12
SW214 W214 12 1-9/16 13-1/8 2-1/2 6-1/2 2-1/2 2 -- -- 10d 2 10d x 1-1/2 2315 2315 2315 -- -- 8, F14, R9
HDO214 HU214TF 12 1-9/16 13 2-1/4 -- -- 2-1/2 4 12 16d 6 10d x 1-1/2 2830 2935 3010 1050 5, F30, R5
SW216 W216 12 1-9/16 15-1/8 2-1/2 6-1/2 2-1/2 2 -- -- 10d 2 10d x 1-1/2 2315 2315 2315 -- -- 8, F14, R9
HDO216 HU216TF, LB216 12 1-9/16 15 2-1/4 -- -- 2-1/2 4 14 16d 8 10d x 1-1/2 3070 3215 3310 1535 5, F30, R5
3 x 4 HDO34 HU34TF 12 2-9/16 3-7/16 2-1/2 -- -- 2-1/2 4 4 16d 2 10d x 1-1/2 2665 2665 2665 315 5, F30, R5
SW36 W36 12 2-9/16 5-3/8 2-1/2 6-1/2 2-1/2 2 -- -- 10d 2 10d x 1-1/2 2315 2315 2315 -- -- 8, F14, R9
HDO36 HU36TF 12 2-9/16 5-3/8 2-1/2 -- -- 2-1/2 4 6 16d 4 10d x 1-1/2 3010 3010 3010 770 5, F30, R5
SW38 W38 12 2-9/16 7-1/8 2-1/2 6-1/2 2-1/2 2 -- -- 10d 2 10d x 1-1/2 2315 2315 2315 -- -- 8, F14, R9
HDO38 B38, HU38TF 12 2-9/16 7-1/8 2-1/2 -- -- 2-1/2 4 8 16d 4 10d x 1-1/2 3605 3605 3605 755 5, F30, R5
SW310 W310 12 2-9/16 9-1/8 2-1/2 6-1/2 2-1/2 2 -- -- 10d 2 10d x 1-1/2 2315 2315 2315 -- -- 8, F14, R9
HDO310 B310, HU310TF 12 2-9/16 9-1/8 2-1/2 -- -- 2-1/2 4 10 16d 6 10d x 1-1/2 4165 4165 4165 1150 5, F30, R5
SWH312 WNP312 7/12 2-9/16 11-1/8 2-1/2 7 2-1/2 2 -- -- 10d 2 10d x 1-1/2 3305 3305 3305 -- -- 8, F14, R9
HDO312 B312, HU312TF 12 2-9/16 11 2-1/2 -- -- 2-1/2 4 12 16d 6 10d x 1-1/2 4475 4475 4475 1150 5, F30, R5
SWH314 WNP314 7/12 2-9/16 13-1/8 2-1/2 7 2-1/2 2 -- -- 10d 2 10d x 1-1/2 3305 3305 3305 -- -- 8, F14, R9
HDO314 B314, HU314TF 12 2-9/16 13 2-1/2 -- -- 2-1/2 4 14 16d 8 10d x 1-1/2 4475 4475 4475 1315 5, F30, R5
SWH316 WNP316 7/12 2-9/16 15-1/8 2-1/2 7 2-1/2 2 -- -- 10d 2 10d x 1-1/2 3305 3305 3305 -- -- 8, F14, R9
HDO316 B316, HU316TF 12 2-9/16 15 2-1/2 -- -- 2-1/2 4 16 16d 8 10d x 1-1/2 4865 5010 5105 1535 5, F30, R5
(2) 2 x 4 HDO24-2 HU24-2TF 12 3-1/8 3-7/16 2-1/4 -- -- 2-1/2 4 4 16d 2 10d 2445 2445 2445 405 5, F30, R5
SWH26-2 WNP26-2 7/12 3-1/8 5-3/8 2-1/2 7 2-1/2 2 -- -- 10d 2 10d 3305 3305 3305 -- -- 8, F14, R9
HDO26-2 HU26-2TF, HUS26-2TF
12 3-1/8 5-3/8 2-1/4 -- -- 2-1/2 4 6 16d 4 10d 3050 3050 3050 815 5, F30, R5
SWH28-2 WNP28-2 7/12 3-1/8 7-1/8 2-1/2 7 2-1/2 2 -- -- 10d 2 10d 3305 3305 3305 -- -- 8, F14, R9
HDO28-2 HU28-2TF, HUS28-2TF
12 3-1/8 7-1/8 2-1/4 -- -- 2-1/2 4 8 16d 4 10d 3825 3825 3825 815 5, F30, R5
SWH210-2 WNP210-2 7/12 3-1/8 9-1/8 2-1/2 7 2-1/2 2 -- -- 10d 2 10d 3305 3305 3305 -- -- 8, F14, R9
HDO210-2 HU210-2TF, HUS210-2TF
12 3-1/8 9-1/8 2-1/2 -- -- 2-1/2 4 10 16d 6 10d 4565 4565 4565 1220 5, F30, R5
1) Uplift Loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) HL, KHW, SW, and SWH products do not provide uplift resistance, except for the HL214. 3) Minimum nail embedment shall be 1-1/2˝ for 10d nails, 1-5/8˝ for 16d nails, and 2˝ for NA20D nails. 4) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 5) NA20D nails are 6 gauge (0.192˝ diameter) by 2-1/2˝ long and are included with KB, KHB, and KHW hangers. 6) KHW Glulam load values are based on 560 psi perpendicular to grain loading.
Dimensions Fastener Schedule3,4 Allowable Loads (Lbs.)5
Header Joist DF-L / SP
Beam/Joist Size
SteelGauge
Qty RoofUSPStock No.
2 x 6
2 x 8
2 x 10
2 x 12
2 x 14
2 x 16
3 x 6
3 x 8
3 x 10
3 x 12
3 x 14
3 x 16
(2) 2 x 6
(2) 2 x 8
(2) 2 x 10
CodeRef.
continued on next page
USP2173-111
Han
gers
1-800-328-5934 • www.USPconnectors.com 99
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Top Mount Hanger Charts continued
Floor Uplift1,2
Ref. No. W H D L TF Qty Type Qty Type 100% 115% 125% 160%
SWH212-2 WNP212-2 7/12 3-1/8 11-1/8 2-1/2 7 2-1/2 2 -- -- 10d 2 10d 3305 3305 3305 -- -- 8, F14, R9
HDO212-2 HU212-2TF, HUS212-2TF
12 3-1/8 11 2-1/2 -- -- 2-1/2 4 12 16d 6 10d 4880 5230 5465 1220 5, F30, R5
SWH214-2 WNP214-2 7/12 3-1/8 13-1/8 2-1/2 7 2-1/2 2 -- -- 10d 2 10d 3305 3305 3305 -- -- 8, F14, R9
HDO214-2 HU214-2TF, HUS214-2TF
12 3-1/8 13 2-1/2 -- -- 2-1/2 4 14 16d 8 10d 5175 5410 5410 1625 5, F30, R5
SWH216-2 WNP216-2 7/12 3-1/8 15-1/8 2-1/2 7 2-1/2 2 -- -- 10d 2 10d 3305 3305 3305 -- -- 8, F14, R9
HDO216-2 HU216-2TF 12 3-1/8 15 2-1/2 -- -- 2-1/2 4 16 16d 8 10d 5475 5855 5960 1625 5, F30, R5
4 x 4 HDO44 HU44TF 12 3-9/16 3-7/16 2-1/4 -- -- 2-1/2 4 4 16d 2 10d 2445 2445 2445 405 5, F30, R5
SW46 W46 12 3-9/16 5-3/8 2-1/2 6-1/2 2-1/2 2 -- -- 10d 2 10d 2520 2520 2520 -- -- 8, F14, R9
HDO46 HU46TF, HUS46TF
12 3-9/16 5-3/8 2-1/4 -- -- 2-1/2 4 6 16d 4 10d 3050 3050 3050 815 5, F30, R5
KHW46 HW46 3/10 3-9/16 5-3/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 5335 5335 5335 -- -- 8, F14, R9
SW48 W48 12 3-9/16 7-1/8 2-1/2 6-1/2 2-1/2 2 -- -- 10d 2 10d 2520 2520 2520 -- -- 8, F14, R9
HDO48 B48, BA48, HU48TF, HUS48TF
12 3-9/16 7-1/8 2-1/4 -- -- 2-1/2 4 8 16d 4 10d 3825 3825 3825 815 5, F30, R5
KHW48 HW48 3/10 3-9/16 7-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 5335 5335 5335 -- -- 8, F14, R9
SW410 W410 12 3-9/16 9-1/8 2-1/2 6-1/2 2-1/2 2 -- -- 10d 2 10d 2520 2520 2520 -- -- 8, F14, R9
HDO410 B410, HU410TF, HUS410TF
12 3-9/16 9-1/8 2-1/4 -- -- 2-1/2 4 10 16d 6 10d 4565 4565 4565 1220 5, F30, R5
SWH410 -- -- 7/12 3-9/16 9-1/8 2-1/2 7 2-1/2 2 -- -- 10d 2 10d 3305 3305 3305 -- -- 8, F14, R9
KHW410 HW410 3/10 3-9/16 9-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 5335 5335 5335 -- -- 8, F14, R9
HDO412 B412, HU412TF, HUS412TF
12 3-9/16 11 2-1/4 -- -- 2-1/2 4 12 16d 6 10d 4880 5230 5465 1220 5, F30, R5
SWH412 WNP412 7/12 3-9/16 11-1/8 2-1/2 7 2-1/2 2 -- -- 10d 2 10d 3305 3305 3305 -- -- 8, F14, R9
KHW412 HW412 3/10 3-9/16 11-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 5335 5335 5335 -- -- 8, F14, R9
HDO414
B414, HHB414, HU414TF, HUI414TF, HUS414TF
12 3-9/16 13 2-1/2 -- -- 2-1/2 4 14 16d 8 10d 5175 5410 5410 1625 5, F30, R5
SWH414 WNP414 7/12 3-9/16 13-1/8 2-1/2 7 2-1/2 2 -- -- 10d 2 10d 3305 3305 3305 -- -- 8, F14, R9
KHW414 HW414 3/10 3-9/16 13-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 5335 5335 5335 -- -- 8, F14, R9
HDO416 B416, HHB416, HU416TF
12 3-9/16 15 2-1/2 -- -- 2-1/2 4 16 16d 8 10d 5475 5915 6210 1625 5, F30, R5
SWH416 WNP416 7/12 3-9/16 15-1/8 2-1/2 7 2-1/2 2 -- -- 10d 2 10d 3305 3305 3305 -- -- 8, F14, R9
KHW416 HW416 3/10 3-9/16 15-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 5335 5335 5335 -- -- 8, F14, R9
(3) 2 x 10 HDO210-3 HU210-3TF 12 4-11/16 9-1/8 2-1/2 -- -- 2-1/2 4 10 16d 6 16d 4565 4565 4565 1430 5, F30, R5
(3) 2 x 12 HDO212-3 HU212-3TF 12 4-11/16 11 2-1/2 -- -- 2-1/2 4 12 16d 6 16d 4880 5230 5465 1430 5, F30, R5
1) Uplift Loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) HL, KHW, SW, and SWH products do not provide uplift resistance, except for the HL214. 3) Minimum nail embedment shall be 1-1/2˝ for 10d nails, 1-5/8˝ for 16d nails, and 2˝ for NA20D nails. 4) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 5) NA20D nails are 6 gauge (0.192˝ diameter) by 2-1/2˝ long and are included with KB, KHB, and KHW hangers. 6) KHW Glulam load values are based on 560 psi perpendicular to grain loading.
Allowable Loads (Lbs.)6
Header Joist DF-L / SP
Dimensions Fastener Schedule3,4,5
Roof
4 x 6
USPStock No.
(2) 2 x 14
(2) 2 x 16
(2) 2 x 12
4 x 16
4 x 8
4 x 10
4 x 12
4 x 14
CodeRef.
Beam/Joist Size
SteelGauge
continued on next page
1-800-328-5934 • www.USPconnectors.com
Han
gers
1-800-328-5934 • www.USPconnectors.com100
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Top Mount Hanger Charts continued
Floor Uplift1
Ref. No. W H D L TF Qty Type Qty Type 100% 115% 125% 160%
(3) 2 x 14 HDO214-3 HU214-3TF 12 4-11/16 13 2-1/2 -- -- 2-1/2 4 14 16d 8 16d 5175 5410 5410 1710 5, F30, R5
(3) 2 x 16 HDO216-3 HU216-3TF 12 4-11/16 15 2-1/2 -- -- 2-1/2 4 16 16d 8 16d 5475 5915 6210 1905 5, F30, R5
HDO66 HU66TF 12 5-1/2 5-3/8 2-1/2 -- -- 2-1/2 4 6 16d 4 16d 3050 3050 3050 955 5, F30, R5
SWH66 WNP66 7/12 5-1/2 5-3/8 2-1/2 7 2-1/2 2 -- -- 10d 2 10d 3305 3305 3305 -- -- 8, F14, R9
KHW66 HW66 3/10 5-1/2 5-3/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 5335 5335 5335 -- -- 8, F14, R9
HDO68 HHB68, HU68TF 12 5-1/2 7-1/8 2-1/2 -- -- 2-1/2 4 8 16d 4 16d 3825 3825 3825 955 5, F30, R5
SWH68 WNP68 7/12 5-1/2 7-1/8 2-1/2 7 2-1/2 2 -- -- 10d 2 10d 3305 3305 3305 -- -- 8, F14, R9
KHW68 HW68 3/10 5-1/2 7-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 5335 5335 5335 -- -- 8, F14, R9
HDO610 B610, HHB610, HU610TF
12 5-1/2 9-1/8 2-1/2 -- -- 2-1/2 4 10 16d 6 16d 4565 4565 4565 1430 5, F30, R5
SWH610 WNP610 7/12 5-1/2 9-1/8 2-1/2 7 2-1/2 2 -- -- 10d 2 10d 3305 3305 3305 -- -- 8, F14, R9
KHW610 HW610 3/10 5-1/2 9-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 5335 5335 5335 -- -- 8, F14, R9
HDO612 B612, HHB612, HU612TF
12 5-1/2 11 2-1/2 -- -- 2-1/2 4 12 16d 6 16d 4880 5230 5465 1430 5, F30, R5
KHW612 HW612 3/10 5-1/2 11-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 5335 5335 5335 -- -- 8, F14, R9
HDO614 B614, HHB614, HU614TF
12 5-1/2 13 2-1/2 -- -- 2-1/2 4 14 16d 8 16d 5175 5410 5410 1710 5, F30, R5
KHW614 HW614 3/10 5-1/2 13-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 5335 5335 5335 -- -- 8, F14, R9
HDO616 B616, HHB616, HU616TF
12 5-1/2 15 2-1/2 -- -- 2-1/2 4 16 16d 8 16d 5475 5915 6210 1905 5, F30, R5
KHW616 HW616 3/10 5-1/2 15-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 5335 5335 5335 -- -- 8, F14, R9
8 x 6 KHW86 HW86 3/10 7-1/2 5-3/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 5335 5335 5335 -- -- 8, F14, R9
8 x 8 KHW88 HW88 3/10 7-1/2 7-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 5335 5335 5335 -- -- 8, F14, R9
8 x 10 KHW810 HW810 3/10 7-1/2 9-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 5335 5335 5335 -- -- 8, F14, R9
8 x 12 KHW812 HHB812, HW812 3/10 7-1/2 11-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 5335 5335 5335 -- -- 8, F14, R9
8 x 14 KHW814 HHB814, HW814 3/10 7-1/2 13-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 5335 5335 5335 -- -- 8, F14, R9
8 x 16 KHW816 HHB816, HW816 3/10 7-1/2 15-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 5335 5335 5335 -- -- 8, F14, R9
2-1/2 glulam KHW26 -- -- 3/10 2-11/16 specify 4 10 2-1/2 4 -- -- NA20D 2 10d x 1-1/2 5295 5295 5295 -- -- 8, F14, R9
3-1/8 glulam KHW3 HW3.25 3/10 3-1/4 specify 3 10 2-1/2 4 -- -- NA20D 2 10d 5295 5295 5295 -- -- 8, F14, R9
5-1/8 glulam KHW5 HW5.25 3/10 5-1/4 specify 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 5295 5295 5295 -- -- 8, F14, R9
1) Uplift Loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) Minimum nail embedment shall be 1-1/2˝ for 10d nails, 1-5/8˝ for 16d nails, and 2˝ for NA20D nails. 3) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 4) NA20D nails are 6 gauge (0.192˝ diameter) by 2-1/2˝ long and are included with KB, KHB, and KHW hangers. 5) KHW Glulam load values are based on 560 psi perpendicular to grain loading. 6) Consult USP for additional Glulam sizes.
Fastener Schedule2,3,4,5 Allowable Loads (Lbs.)6
Header Joist
6 x 8
Dimensions
SteelGauge
RoofUSPStock No.
6 x 6
CodeRef.
DF-L / SP
Beam/Joist Size
Glulam Sizes6
6 x 10
6 x 12
6 x 14
6 x 16
USP2173-111
Han
gers
1-800-328-5934 • www.USPconnectors.com 101
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Multi-Purpose Joist Hangers – JH series
TF
WD
H
B
Raiseddimple allows
30º to 45˚nailing
JH20
A field-adjustable seat gives the LS hanger application flexibility.
The LS hanger slopes from 0° to 30° down (0 to 7:12 pitch down).
Materials: 18 gaugeFinish: G90 galvanizingCodes: ESR-1465, FL817
Installation:• Use all specified fasteners. See Product Notes, page 11.• The LS can be field adjusted to slopes from 0° to 30° down.
W3˝
H
LS268
Floor Uplift1
Ref. No. W H Qty Type Qty Type 100% 115% 125% 160%
7 10d x 1-1/2 7 10d x 1-1/2 785 900 980 675
7 16d 7 10d x 1-1/2 960 1105 1170 675
9 10d x 1-1/2 9 10d x 1-1/2 1010 1160 1260 10359 16d 9 10d x 1-1/2 1235 1370 1370 1035
1) Uplift loads are increased 60% for wind or seismic loads; no further increase shall be permitted. 2) Minimum nail embedment shall be 1-1/2˝ for 10d nails and 1-5/8˝ for 16d nails. 3) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long.
Dimensions
DF-L / SPHeader Joist
Fastener Schedule2,3Allowable Loads (Lbs.)
CodeRef.
11, F12
JoistSize
USPStock No.
SteelGauge
Roof
2 x 6 - 8 LS268 -- -- 18 1-9/16 5-1/2
2 x 10 LS210 -- -- 18 1-9/16 7-7/8
Header Top Face Floor Uplift1
Joist Size Ref. No. W H D B TF Size Qty Qty Type Qty Type 100% 115% 125% 160%
1-3/16 2 x 6 2 4 10d 6 10d 1900 2060 2165 12851-7/16 2 x 8 2 8 10d 6 10d 2540 2765 2900 1285
7/16 2 x 10 2 12 10d 6 10d 2270 2565 2760 1285-- -- 2 x 12 -- -- 14 10d 6 10d 2185 2510 2730 1285
1) Uplift Loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) Nails must be driven at a 30° to 45˚ angle through the joist or truss into header to achieve the table loads. 3) 16d sinkers (9 gauge x 3-1/4˝ long) may be used where 10d commons are specified with no reduction in load.
DF-L / SP
Fastener Schedule2,3
JoistHeader
Allowable Loads (Lbs.)
5-1/82-1/4
USPStock No.
SteelGauge
Dimensions
CodeRef.
8, F14, R9 2 x 6 - 12 JH20 -- -- 18
Roof
1-9/16 10-1/16
Light Slope Hangers – LS series
Typical LS268installation
These strap-style hangers are designed to support trusses, joists, or purlins. JH models may be bent along the flange allowingbuilders to use the hangers in top mount, face mount, or combination applications.
Materials: 18 gaugeFinish: G90 galvanizingCodes: ESR-2104, FL820, LA City RR 25745
Installation:• Use all specified fasteners. See Product Notes, page 11.• Joist nails must be driven at a 30° to 45° angle through the joistor truss into the header to achieve listed loads. Standard length“double shear” nails must be used to achieve listed load values.• If installing in top mount configuration, field bend top flange overheader.• 16d sinkers (9 gauge x 31/4˝) may be used where 10d commonare specified with no load reduction.
Double shear nail designfeatures fewer nails and
faster installation
Uses standard length nails
1-800-328-5934 • www.USPconnectors.com
Floor Uplift1
Ref. No. W H D L TF Qty Type Qty Type 100% 115% 125% 160%
(3) 2 x 14 HDO214-3 HU214-3TF 12 4-11/16 13 2-1/2 -- -- 2-1/2 4 14 16d 8 16d 5175 5410 5410 1710 5, F30, R5
(3) 2 x 16 HDO216-3 HU216-3TF 12 4-11/16 15 2-1/2 -- -- 2-1/2 4 16 16d 8 16d 5475 5915 6210 1905 5, F30, R5
HDO66 HU66TF 12 5-1/2 5-3/8 2-1/2 -- -- 2-1/2 4 6 16d 4 16d 3050 3050 3050 955 5, F30, R5
SWH66 WNP66 7/12 5-1/2 5-3/8 2-1/2 7 2-1/2 2 -- -- 10d 2 10d 3305 3305 3305 -- -- 8, F14, R9
KHW66 HW66 3/10 5-1/2 5-3/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 5335 5335 5335 -- -- 8, F14, R9
HDO68 HHB68, HU68TF 12 5-1/2 7-1/8 2-1/2 -- -- 2-1/2 4 8 16d 4 16d 3825 3825 3825 955 5, F30, R5
SWH68 WNP68 7/12 5-1/2 7-1/8 2-1/2 7 2-1/2 2 -- -- 10d 2 10d 3305 3305 3305 -- -- 8, F14, R9
KHW68 HW68 3/10 5-1/2 7-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 5335 5335 5335 -- -- 8, F14, R9
HDO610 12 5-1/2 9-1/8 2-1/2 -- -- 2-1/2 4 10 16d 6 16d 4565 4565 4565 1430 5, F30, R5
SWH610 WNP610 7/12 5-1/2 9-1/8 2-1/2 7 2-1/2 2 -- -- 10d 2 10d 3305 3305 3305 -- -- 8, F14, R9
KHW610 HW610 3/10 5-1/2 9-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 5335 5335 5335 -- -- 8, F14, R9
HDO612 12 5-1/2 11 2-1/2 -- -- 2-1/2 4 12 16d 6 16d 4880 5230 5465 1430 5, F30, R5
KHW612 HW612 3/10 5-1/2 11-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 5335 5335 5335 -- -- 8, F14, R9
HDO614 12 5-1/2 13 2-1/2 -- -- 2-1/2 4 14 16d 8 16d 5175 5410 5410 1710 5, F30, R5
KHW614 HW614 3/10 5-1/2 13-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 5335 5335 5335 -- -- 8, F14, R9
HDO616 12 5-1/2 15 2-1/2 -- -- 2-1/2 4 16 16d 8 16d 5475 5915 6210 1905 5, F30, R5
KHW616 HW616 3/10 5-1/2 15-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 5335 5335 5335 -- -- 8, F14, R9
8 x 6 KHW86 HW86 3/10 7-1/2 5-3/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 5335 5335 5335 -- -- 8, F14, R9
8 x 8 KHW88 HW88 3/10 7-1/2 7-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 5335 5335 5335 -- -- 8, F14, R9
8 x 10 KHW810 HW810 3/10 7-1/2 9-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 5335 5335 5335 -- -- 8, F14, R9
8 x 12 KHW812 HHB812, HW812 3/10 7-1/2 11-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 5335 5335 5335 -- -- 8, F14, R9
8 x 14 KHW814 HHB814, HW814 3/10 7-1/2 13-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 5335 5335 5335 -- -- 8, F14, R9
8 x 16 KHW816 HHB816, HW816 3/10 7-1/2 15-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 5335 5335 5335 -- -- 8, F14, R9
2-1/2 glulam KHW26 -- -- 3/10 2-11/16 specify 4 10 2-1/2 4 -- -- NA20D 2 10d x 1-1/2 5295 5295 5295 -- -- 8, F14, R9
3-1/8 glulam KHW3 HW3.25 3/10 3-1/4 specify 3 10 2-1/2 4 -- -- NA20D 2 10d 5295 5295 5295 -- -- 8, F14, R9
5-1/8 glulam KHW5 HW5.25 3/10 5-1/4 specify 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 5295 5295 5295 -- -- 8, F14, R9
1) Uplift Loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) Minimum nail embedment shall be 1-1/2˝ for 10d nails, 1-5/8˝ for 16d nails, and 2˝ for NA20D nails. 3) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 4) NA20D nails are 6 gauge (0.192˝ diameter) by 2-1/2˝ long and are included with KB, KHB, and KHW hangers. 5) KHW Glulam load values are based on 560 psi perpendicular to grain loading. 6) Consult USP for additional Glulam sizes.
Han
gers
1-800-328-5934 • www.USPconnectors.com102
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Skewed 45° Hangers – SKH & SKHH series
Floor Uplift1Floor Uplift1
Beam / Joist Size Ref. No. W H D Qty Type Qty Type 100% 115% 125% 160% 100% 115% 125% 160%
2 x 4 SKH24L/R SUR/L24 16 1-9/16 3-1/4 1-7/8 4 16d 4 10d x 1-1/2 510 510 510 565 475 510 510 565 5, F30, R5
SKH26L/R SUR/L26 6 16d 6 10d x 1-1/2 SKH26L/R-GC -- -- 6 N16C-GC 6 N10-GC
2 x 8 - 10 - 12 SKH28L/R -- -- 16 1-9/16 7-1/4 1-7/8 10 16d 8 10d x 1-1/2 1380 1465 1465 1360 1190 1370 1465 1240
SKH210L/R SUR/L210, SUR/L214
14 16d 10 10d x 1-1/2
SKH210L/R-GC -- -- 14 N16C-GC 10 N10-GC
1 3/4 x 9-1/4 - 14 SKH1720L/R SUR/L1.81/9 16 1-13/16 9-1/8 1-7/8 14 10d 10 10d x 1-1/2 1625 1870 2030 1565 1400 1610 1750 1550
1-3/4 x 11-1/4 - 18 SKH1724L/R SUR/L1.81/11, SUR/L1.81/14
16 1-13/16 11-1/8 1-7/8 16 10d 10 10d x 1-1/2 1855 2135 2320 1565 1600 1840 2000 1550
2 - 2-1/8 x 9-1/4 - 14 SKH2020L/R SURI/LI2.06/9, SUR/L2.1/9 16 2-1/8 9 1-7/8 14 10d 10 10d x 1-1/2 1625 1870 2030 1565 1400 1610 1750 1550
2 - 2-1/8 x 11-1/4 - 18 SKH2024L/R SUR/L2.06/11, SUR/L2.1/11
16 2-1/8 11 1-7/8 16 10d 10 10d x 1-1/2 1855 2135 2320 1565 1600 1840 2000 1550
2-1/4 - 2-5/16 x 9-1/4 - 14
SKH2320L/R SUR/L2.37/9 16 2-3/8 8-7/8 1-7/8 14 10d 10 10d x 1-1/2 1625 1870 2030 1565 1400 1610 1750 1550
2-1/4 - 2-5/16 x 11-1/4 - 18
SKH2324L/R SUR/L2.37/11, SUR/L2.37/14
16 2-3/8 10-7/8 1-7/8 16 10d 10 10d x 1-1/2 1855 2135 2320 1565 1600 1840 2000 1550
3 x 6 - 8 SKH36L -- -- 16 2-9/16 4-3/4 1-3/8 6 16d 6 10d x 1-1/2 830 950 1025 1085 715 820 895 930
3 x 8 - 10 - 12 SKH38L/R -- -- 16 2-9/16 6-3/4 1-3/8 10 16d 8 10d x 1-1/2 1380 1585 1585 1360 1190 1370 1490 1240 3 x 10 - 12 - 14 SKH310L/R -- -- 16 2-9/16 8-3/4 1-3/8 14 16d 10 10d x 1-1/2 1930 2220 2250 1565 1665 1915 2085 1550
3 x 12 - 14 - 16 SKH312L/R -- -- 16 2-9/16 10-3/4 1-3/8 16 16d 10 10d x 1-1/2 2210 2500 2500 1565 1905 2190 2380 1550
2-1/2 x 9-1/4 - 14 SKH2520L/R SUR/L2.56/9 16 2-9/16 8-5/8 1-7/8 14 10d 10 10d x 1-1/2 1625 1870 2030 1565 1400 1610 1750 1550
2-1/2 x 11-1/4 - 16 SKH2524L/R SUR/L2.56/11, SUR/L2.56/14
16 2-9/16 10-3/4 1-7/8 16 10d 10 10d x 1-1/2 1855 2135 2320 1565 1600 1840 2000 1550
2-5/8 x 9-1/4 - 14 SKH2620L/R -- -- 16 2-11/16 8-11/16 1-7/8 14 10d 10 10d x 1-1/2 1625 1870 2030 1565 1400 1610 1750 1550 2-5/8 x 11-1/4 - 16 SKH2624L/R -- -- 16 2-11/16 10-11/16 1-7/8 16 10d 10 10d x 1-1/2 1855 2135 2320 1565 1600 1840 2000 1550
1) Uplift loads have been increased 60% for wind and seismic loads; no further increase shall be permitted. 2) 10d x 1-1/2 nails and N10-GC are 9 gauge (0.148˝ diameter) by 1-1/2˝" long. 3) Minimum nail embedment shall be 1-1/2˝ for 10d nails and 1-5/8˝ for 16d and N16C-GC nails.
1-9/16 9-1/4 1-7/8 1665 1550
930
1790 1790 1790 1565
1085 715
1790 1790
1-9/16 5-1/4 1-7/8
Dimensions
890890 890
Fastener Schedule2,3
DF-L / SP
Roof
Header Joist
Allowable Loads (Lbs.)
Roof
S-P-F
2 x 6 - 8
2 x 10 - 12 - 14
SteelGauge
16
16
CodeRef.
USPStock No.
5,F30,R5
5, F6,F30, D3, R5
830 820
SKH26LLeft skew
continued on next page
SKH – Standard 45° skew hanger allows for a 40° to 50° skew range, without hanger modification.
SKHH – For heavier applications.
Materials: 14 or 16 gaugeFinish: G90 galvanizing; SKH26L/R-GC & SKH210L/R-GC – Gold Coat
Options: SKH26L/R, SKH28L/R, & SKH210L/R are available in Triple Zinc. To order, add TZ to stock number, as in SKH26L-TZ. SKH26L/R, & SKH210L/R are available in Stainless Steel. To order, addSS to stock number, as in SKH26L-SS.
Codes: ESR-1781, FL13285, Dade County, FL 07-0214.20, FL570, L.A. City RR 25843
Installation:• Use all specified fasteners. See Product Notes, page 11.• The hangers listed are for standard sizes and will accommodate a 40° to 50° skewrange. • Most sizes do not require a miter cut for installation. Refer to chart footnote identified with an asterisk.• Illustrations show left and right skews. (SKH_L = skewed left; SKH_R = skewed right)• For I-Joist installations, web stiffeners are required.• Refer to illustration for staggered I-Joist application for double 2 ,̋ 25/16 ,̋ and 21/2˝models.• For double I-Joist installations, web stiffeners between I-Joists are required.
Drive nailsat angle
Left skewRight skew
SKH26RRight skew
USP2173-111
Han
gers
1-800-328-5934 • www.USPconnectors.com 103
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Skewed 45° Hangers – SKH & SKHH series continued
1-800-328-5934 • www.USPconnectors.com
H
DW
H
DW
SKHH210L
WD
H
SKH210L
Floor Uplift1Floor Uplift1
Beam / Joist Size Ref. No. W H D Qty Type Qty Type 100% 115% 125% 160% 100% 115% 125% 160%
(2) 2 x 6 - 8 SKH26L/R-2 * SUR/L26-2 16 3-1/16 4-1/2 1-3/8 6 16d 6 10d 830 950 1035 1115 715 820 895 960
(2) 2 x 8 - 10 - 12 SKH28L/R-2 * -- -- 16 3-1/16 6-1/2 1-3/8 10 16d 8 10d 1380 1585 1725 1360 1190 1370 1490 1280
(2) 2 x 10 - 12 - 14 SKH210L/R-2 * SUR/L210-2, SUR/L214-2
16 3-1/16 8-1/2 1-3/8 14 16d 10 10d 1930 2220 2415 1565 1665 1915 2085 1565
3-1/2 x 8 - 14 SKH410L/R * SUR/L410 14 3-9/16 8-1/2 2-1/2 16 16d 10 16d 2255 2540 2540 1565 1935 2225 2420 1565
3-1/2 x 12 - 18 SKH414L/R * SUR/L414 14 3-9/16 12-1/2 2-1/2 22 16d 10 16d 3100 3565 3880 1565 2660 3060 3330 1565
4 x 6 - 8 SKH46L/R * SUR/L46 14 3-9/16 4-3/4 2-1/2 10 16d 6 16d 1410 1590 1590 1355 1210 1390 1515 1160 4 x 10 - 12 - 14 SKH410L/R * SUR/L410 14 3-9/16 8-1/2 2-1/2 16 16d 10 16d 2255 2540 2540 1565 1935 2225 2420 1565
4 x 14 - 16 - 18 SKH414L/R * SUR/L414 14 3-9/16 12-1/2 2-1/2 22 16d 10 16d 3100 3565 3880 1565 2660 3060 3330 1565
(2) 2 - 2-1/8 x 9-1/4 - 14
SKH2020L/R-2 * HSUR/L4.12/9, HSUR/L4.28/9 14 4-3/16 9-1/4 3-1/2 14 10d 10 10d 1665 1915 2085 1905 1440 1660 1805 1650
(2) 2 - 2-1/8 x 11-1/4 - 18
SKH2024L/R-2 *
HSUR/L4.12/11, HSUR/L4.12/14, HSUR/L4.12/16, HSUR/L4.28/11
14 4-3/16 11-1/4 3-1/2 16 10d 10 10d 1905 2190 2380 1905 1650 1895 2060 1650
(2) 2-5/16 x 9-1/4 - 14 SKH2320L/R-2 * HSUR/L4.75/9 14 4-7/8 9-1/4 3-1/2 14 10d 10 10d 1665 1915 2085 1905 1440 1660 1805 1650
(2) 2-5/16 x 11-1/4 - 18
SKH2324L/R-2 * HSUR/L4.75/11, HSUR/4.75/14, HSUR/4.75/16
14 4-7/8 11-1/4 3-1/2 16 10d 10 10d 1905 2190 2380 1905 1650 1895 2060 1650
(2) 2-1/2 x 9-1/4 - 14 SKH2520L/R-2 * HSUR/L5.12/9 14 5-1/8 9-1/4 3-1/2 14 10d 10 10d 1665 1915 2085 1905 1440 1660 1805 1650
(2) 2-1/2 x 11-1/4 - 16 SKH2524L/R-2 * HSUR/L5.12/11, HSUR/L5.12/14, HSUR/L5.12/16
14 5-1/8 11-1/4 3-1/2 16 10d 10 10d 1905 2190 2380 1905 1650 1895 2060 1650
2 x 6 - 8 SKHH26L/R -- -- 14 1-5/8 5-1/8 3-1/4 18 16d 12 10d x 1-1/2 1510 1740 1890 2190 1305 1505 1635 1900 2 x 8 - 10 - 12 SKHH28L/R -- -- 14 1-5/8 7 3-1/4 26 16d 16 10d x 1-1/2 2185 2510 2730 2920 1890 2170 2360 2535
2 x 10 - 12 - 14 SKHH210L/R -- -- 14 1-5/8 9 4-1/4 34 16d 20 10d x 1-1/2 2855 3285 3570 3650 2470 2840 3085 3170
(2) 2 x 6 - 8 SKHH26L/R-2 HSUR/L26-2 14 3-1/16 5-1/4 2 12 16d 4 16d x 2-1/2 1680 1930 2100 895 1450 1670 1815 775
(2) 2 x 10 - 12 - 14 SKHH210L/R-2 HSUR/L210-2, HSUL214-2
14 3-1/16 8-1/2 2 20 16d 6 16d x 2-1/2 2800 3220 3500 1345 2420 2785 3025 1160
4 x 6 - 8 SKHH46L/R HSUR/L46 14 3-9/16 5-1/4 2-1/2 12 16d 6 16d 1680 1930 2100 1345 1450 1670 1815 1160
4 x 10 - 12 - 14 SKHH410L/R HSUR/L410 14 3-9/16 8-1/2 2-1/2 20 16d 10 16d 2800 3220 3500 2240 2420 2785 3025 1935 4 x 14 - 16 - 18 SKHH414L/R HSUR/L414 14 3-9/16 12-1/2 2-1/2 26 16d 10 16d 3640 4185 4550 2240 3145 3620 3935 1935
1) Uplift loads have been increased 60% for wind and seismic loads; no further increase shall be permitted. 2) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝" long. 3) 16d x 2-1/2 nails are 8 gauge (0.162˝ diameter) by 2-1/2˝ long. 4) Minimum nail embedment shall be 1-1/2˝ for 10d nails and 1-5/8˝ for 16d nails. *Miter cut required on end of joist to achieve design loads.
Dimensions Fastener Schedule2,3,4Allowable Loads (Lbs.)
DF-L / SP S-P-FHeader Joist
RoofRoofSteelGauge
130
5,F30,R5
USPStock No.
CodeRef.
H
DWWD
H
SKH210R SKHH210L-2 SKH2520R-2
Typical SKH2520R-2staggered I-Joist installation
Right skew
Typical SKH26LinstallationLeft skew
Floor
Beam / Joist Size Ref. No. W H D Qty Type Qty Type 100% 115% 125% 160% 100% 115% 125% 160%
2 x 4 SKH24L/R SUR/L24 16 1-9/16 3-1/4 1-7/8 4 16d 4 10d x 1-1/2 510 510 510 565 475 510 510 565 5, F30, R5
SKH26L/R SUR/L26 6 16d 6 10d x 1-1/2 SKH26L/R-GC -- -- 6 N16C-GC 6 N10-GC
2 x 8 - 10 - 12 SKH28L/R -- -- 16 1-9/16 7-1/4 1-7/8 10 16d 8 10d x 1-1/2 1380 1465 1465 1360 1190 1370 1465 1240
SKH210L/R 14 16d 10 10d x 1-1/2
SKH210L/R-GC -- -- 14 N16C-GC 10 N10-GC
1 3/4 x 9-1/4 - 14 SKH1720L/R SUR/L1.81/9 16 1-13/16 9-1/8 1-7/8 14 10d 10 10d x 1-1/2 1625 1870 2030 1565 1400 1610 1750 1550
1-3/4 x 11-1/4 - 18 SKH1724L/R 16 1-13/16 11-1/8 1-7/8 16 10d 10 10d x 1-1/2 1855 2135 2320 1565 1600 1840 2000 1550
2 - 2-1/8 x 9-1/4 - 14 SKH2020L/R 16 2-1/8 9 1-7/8 14 10d 10 10d x 1-1/2 1625 1870 2030 1565 1400 1610 1750 1550
2 - 2-1/8 x 11-1/4 - 18 SKH2024L/R 16 2-1/8 11 1-7/8 16 10d 10 10d x 1-1/2 1855 2135 2320 1565 1600 1840 2000 1550
SKH2320L/R SUR/L2.37/9 16 2-3/8 8-7/8 1-7/8 14 10d 10 10d x 1-1/2 1625 1870 2030 1565 1400 1610 1750 1550
SKH2324L/R 16 2-3/8 10-7/8 1-7/8 16 10d 10 10d x 1-1/2 1855 2135 2320 1565 1600 1840 2000 1550
3 x 6 - 8 SKH36L -- -- 16 2-9/16 4-3/4 1-3/8 6 16d 6 10d x 1-1/2 830 950 1025 1085 715 820 895 930
3 x 8 - 10 - 12 SKH38L/R -- -- 16 2-9/16 6-3/4 1-3/8 10 16d 8 10d x 1-1/2 1380 1585 1585 1360 1190 1370 1490 1240 3 x 10 - 12 - 14 SKH310L/R -- -- 16 2-9/16 8-3/4 1-3/8 14 16d 10 10d x 1-1/2 1930 2220 2250 1565 1665 1915 2085 1550
3 x 12 - 14 - 16 SKH312L/R -- -- 16 2-9/16 10-3/4 1-3/8 16 16d 10 10d x 1-1/2 2210 2500 2500 1565 1905 2190 2380 1550
2-1/2 x 9-1/4 - 14 SKH2520L/R SUR/L2.56/9 16 2-9/16 8-5/8 1-7/8 14 10d 10 10d x 1-1/2 1625 1870 2030 1565 1400 1610 1750 1550
2-1/2 x 11-1/4 - 16 SKH2524L/R 16 2-9/16 10-3/4 1-7/8 16 10d 10 10d x 1-1/2 1855 2135 2320 1565 1600 1840 2000 1550
2-5/8 x 9-1/4 - 14 SKH2620L/R -- -- 16 2-11/16 8-11/16 1-7/8 14 10d 10 10d x 1-1/2 1625 1870 2030 1565 1400 1610 1750 1550 2-5/8 x 11-1/4 - 16 SKH2624L/R -- -- 16 2-11/16 10-11/16 1-7/8 16 10d 10 10d x 1-1/2 1855 2135 2320 1565 1600 1840 2000 1550
Typical KFinstallation
Typical PHG26installation
KF – Fastens to joist ends quickly with nails.
PHG – Features a gripper design to hold the joist in place without nailing during the assembly process.
Materials: 18 gaugeFinish: G90 galvanizingCodes: ESR-1280, FL11664,
L.A. City RR 25749
Installation:• Use all specified fasteners. See Product Notes, page 11.• In panelized construction, installers are allowed to nailthrough both the sheathing and the hanger top flange with (1)10d nail. The nail should be centered in the top flange and beno closer than 1/4˝ from the back or front edge of the top flange.• Use locator window to center hanger on purlin center line.• KF & PHG – These hangers do not provide uplift resistance.
Han
gers
1-800-328-5934 • www.USPconnectors.com104
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
Materials: 20 gaugeFinish: G90 galvanizingCodes: ESR-1465, FL817
Installation:• Use all specified fasteners. See Product Notes,page 11.• Diamond holes allow optional header nailing.• Joist nails must be driven at a 30° to 45° anglethrough the purlin into the header to achieve listedloads. Standard length “double shear” nailsmust be used to achieve listed load values.• 16d sinkers (9 gauge x 31/4˝ ) may be used where10d commons are specified with no load reduction.
Top Face Floor Uplift1Floor Uplift1
Ref. No. W H TF Qty Qty Type Qty Type 100% 115% 125% 160% 100% 115% 125% 160%
2 -- -- 10d 2 10d 1070 1070 1070 315 800 800 800 235
2 2 10d 2 10d 1275 1275 1275 470 950 950 950 350
2 -- -- 10d 2 10d 1070 1070 1070 315 800 800 800 2352 2 10d 2 10d 1275 1275 1275 470 950 950 950 350
1) Uplift loads have been increased 60% for wind and seismic loads; no further increase shall be permitted. 2) JPF cannot be used back to back on a single ply header when optional nailing is used. 3) Minimum nail embedment shall be 1-1/2˝ for 10d nails.
20 3-3/8
5-3/8
1-9/16
2 x 6 JPF26 PF26 20
2 x 4 JPF24 PF24
Dimensions Allowable Loads (Lbs.)
DF-L / SP S-P-FHeader2
Joist
Fastener Schedule3
11, F12
Roof CodeRef.
PurlinSize
USPStock No.
SteelGauge
Roof
1-9/16
1-1/16
1-1/16
Double shear nail design features fewer nails and
faster installation
Uses standard length nails
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Panel Hangers – KF & PHG series
1-800-328-5934 • www.USPconnectors.com
TF
H
W D
Locatorwindows
KF
TF
H
W D
Locatorwindows
PHG26
DF-L / SP
Ref. No. W H D TF5 Qty Type Qty Type 125% 2 x 4 PHG24 HF24N 18 1-9/16 3-1/2 1-3/16 1-1/16 2 8d -- -- -- -- 580
2 x 6 PHG26 F26P, HF26N 18 1-9/16 5-3/8 1 1-1/16 2 10d -- -- -- -- 650
3 x 4 PHG34 HF34N 18 2-9/16 3-1/2 1 1-1/8 2 10d -- -- -- -- 650 3 x 6 PHG36 HF36N 18 2-9/16 5-3/8 1 1-1/8 2 10d -- -- -- -- 650
(2) 2 x 4 PHG24-2 F24-2 18 3-1/8 3-1/2 1 1-1/8 2 10d -- -- -- -- 650 (2) 2 x 6 PHG26-2 F26-2 18 3-1/8 5-3/8 1 1-1/8 2 10d -- -- -- -- 650
4 x 4 KF44 F44 18 3-9/16 3-3/8 1 1-1/8 2 10d 1 10d x 1-1/2 695
4 x 6 KF46 F46 18 3-9/16 5-3/8 1 1-1/8 2 10d 1 10d x 1-1/2 810
Joist SizeUSP
Stock No.Steel
Gauge
Dimensions
2,F20,R12
Joist
Fastener Schedule2,3Allowable
Loads (Lbs.)1Header
CodeRef.
Purlin Hangers – JPF series
Typical JPF24back-to-back installation
TF
H
W 1 1/2˝
Raiseddimple allows30º to 45˚nailing
JPF24
Typical JPF24installation
1) Loads listed are per side. 2) Minimum nail embedment shall be 1-5/16˝ for 8d nails and 1-1/2˝ for 10d nails. 3) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long.
USP2173-111
Han
gers
1-800-328-5934 • www.USPconnectors.com 105
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Purlin Hangers – JDS series
JDS24S
JDS26(JDS24 similar)
JDS26-175installation
JDS26-175
Materials: 18 gaugeFinish: G90 galvanizing
Installation:• Use all specified fasteners. See Product Notes,page 11.• Joist nails must be driven at a 30° to 45° anglethrough the purlin into the header to achieve listedloads. Standard length “double shear” nailsmust be used to achieve listed load values..
Typical JDS26installation
TF
H
W
TF
H
WTypical JDS24Sinstallation
Starburst prongfor temporary attachment to truss
Double shear nail design features fewer nails and
faster installation
Uses standard length nails
NEW &IMPROVEDSADDLE DESIGNStarburst prong
for temporary attachment to
truss
Raised dimpleallows 30˚ to
45˚ nailing
Top opening ofstarburst prong
provides a witness hole
Top Face Floor Uplift1
Ref. No. W H TF Qty Qty Type Qty Type 100% 115% 125% 160%
JDS24S Min 1 2 10d x 1-1/2 2 10d x 1-1/2 480 480 480 180
JDS24S Max 2 -- -- 10d x 1-1/2 2 10d 575 575 575 340 JDS26S Min 1 2 10d x 1-1/2 4 10d x 1-1/2 550 550 550 300
JDS26S Max 2 -- -- 10d x 1-1/2 4 10d 775 830 835 390
JDS24 Min 2 4 10d x 1-1/2 2 10d x 1-1/2 960 960 960 360
JDS24 Max 4 -- -- 10d x 1-1/2 4 10d 1155 1155 1155 680
JDS26-175 -- -- 18 1-9/16 5-7/16 1-3/4 2 4 10d x 1-1/2 4 10d x 1-1/2 1105 1105 1105 595
JDS26 Min 2 4 10d x 1-1/2 4 10d x 1-1/2 1105 1105 1105 595 JDS26 Max 4 -- -- 10d x 1-1/2 8 10d 1575 1670 1670 775
1) Uplift loads have been increased 60% for wind and seismic loads; no further increase shall be permitted. 2) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 3) Minimum nail embedment shall be 1-1/2˝ for 10d nails. New products or updated product information are designated in bold font.
2 x 6 saddle
Header
Fastener Schedule2,3
USPStock No.
SteelGauge
Dimensions
18
18
18
18
1-9/16
1-9/16
1-9/16
1-9/16 1-9/16
3-1/2
3-1/2
5-1/2
5-1/2 PFD26
Allowable Loads (Lbs.)
CodeRef.
3/4
Each Purlin
Roof
DF-L / SP
110
3/4
1-9/16
PurlinSize
PF24A
PFD24
PF26A
2 x 4single
2 x 4saddle
2 x 6single
Raised dimpleallows 30˚ to
45˚ nailing
Han
gers
1-800-328-5934 • www.USPconnectors.com106
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Versatile heavy-duty top flange hanger attaches to bothwood and masonry. Unique design allows builders to useone style hanger on the job when the structure has a variety of support materials.
Materials: Top Flange – 1/4˝ steel; Stirrup – 7 gaugeFinish: USP primer
Options: See Specialty Options Chart on page 107.Codes: 2031C, FL859
Installation:• Use all specified fasteners. See Product Notes, page 11.• NA21 nails are included with hangers where specified.• NA21 nails are not recommended for use with LVL,PSL, or LSL headers.• Masonry design load values apply to both solid concretetie beams and grout-filled CMU walls.• Alternate installation – Use (2) 1/2˝ x 4˝ PowersFasteners Wedge-Bolts® or equal for loads up to 2,400 lbs.when attaching to CMU. Loads shall not exceed table loads.
H
W
3 1/2˝ 3 1/2˝
10˝
Typical HWUH410wood-to-wood installation
Typical HWUH410wood-to-masonry installationHWUH410
Floor Uplift4
Ref. No. W H Qty Type Qty Type 100% 115% 125% 160%
6 10d 4 10d x 1-1/2 2265 2265 2265 930
2 1/2 x 6 Emb. J-Bolt 4 10d x 1-1/2 2265 2265 2265 930
6 10d 4 10d x 1-1/2 2265 2265 2265 9302 1/2 x 6 Emb. J-Bolt 4 10d x 1-1/2 2265 2265 2265 930
6 10d 4 10d x 1-1/2 2265 2265 2265 9302 1/2 x 6 Emb. J-Bolt 4 10d x 1-1/2 2265 2265 2265 930
6 10d 4 10d x 1-1/2 2265 2265 2265 930
2 1/2 x 6 Emb. J-Bolt 4 10d x 1-1/2 2265 2265 2265 9306 10d 4 10d x 1-1/2 2265 2265 2265 930
2 1/2 x 6 Emb. J-Bolt 4 10d x 1-1/2 2265 2265 2265 9306 10d 4 10d x 1-1/2 2265 2265 2265 930
2 1/2 x 6 Emb. J-Bolt 4 10d x 1-1/2 2265 2265 2265 930
6 10d 4 10d 3800 3800 3800 10352 1/2 x 6 Emb. J-Bolt 4 10d 3800 3800 3800 1035
6 10d 4 10d 3800 3800 3800 1035
2 1/2 x 6 Emb. J-Bolt 4 10d 3800 3800 3800 10356 10d 4 10d 3800 3800 3800 1035
2 1/2 x 6 Emb. J-Bolt 4 10d 3800 3800 3800 10356 10d 4 10d 3800 3800 3800 1035
2 1/2 x 6 Emb. J-Bolt 4 10d 3800 3800 3800 1035
6 10d 4 10d 3800 3800 3800 10352 1/2 x 6 Emb. J-Bolt 4 10d 3800 3800 3800 1035
6 10d 4 10d 3800 3800 3800 10352 1/2 x 6 Emb. J-Bolt 4 10d 3800 3800 3800 1035
6 10d 4 10d 3800 3800 3800 1035
2 1/2 x 6 Emb. J-Bolt 4 10d 3800 3800 3800 10356 10d 4 10d 3800 3800 3800 1035
2 1/2 x 6 Emb. J-Bolt 4 10d 3800 3800 3800 10356 10d 4 10d 3800 3800 3800 1035
2 1/2 x 6 Emb. J-Bolt 4 10d 3800 3800 3800 1035
6 10d 4 10d 3800 3800 3800 10352 1/2 x 6 Emb. J-Bolt 4 10d 3800 3800 3800 1035
6 10d 4 10d 3800 3800 3800 1035
2 1/2 x 6 Emb. J-Bolt 4 10d 3800 3800 3800 10356 10d 4 10d 3800 3800 3800 1035
2 1/2 x 6 Emb. J-Bolt 4 10d 3800 3800 3800 1035
CodeRef.
L1, F17
Dimensions
2 x 8 HWUH28 -- --
Beam/Joist Size
USPStock No.
2 x 4 - 6 -- -- 1-5/8 HWUH26
Allowable Loads (Lbs.)
Roof
DF-L / SP
Fastener Schedule1,3
Header Joist
HWUH210 -- --
2 x 12 HWUH212 -- --
2 x 10
2 x 14 HWUH214 -- --
2 x 16 HWUH216 -- --
3 x 6 HWUH36 -- --
3 x 8 HWUH38 -- --
3 x 10 HWUH310 -- --
3 x 12 HWUH312 -- --
3 x 14 HWUH314 -- --
3 x 16 HWUH316 -- --
(2) 2 x 6 HWUH26-2 -- --
(2) 2 x 8 HWUH28-2 -- --
(2) 2 x 10 HWUH210-2 -- --
(2) 2 x 12 HWUH212-2 -- --
(2) 2 x 14 HWUH214-2 -- --
(2) 2 x 16 HWUH216-2 -- --
1-5/8
1-5/8
1-5/8
1-5/8
1-5/8
2-5/8
2-5/8
2-5/8
2-5/8
2-5/8
2-5/8
3-1/8
3-1/8
3-1/8
3-1/8
5-3/8
7-1/8
9-1/8
5-3/8
11
13
5-3/8
7-1/8
9-1/8
16
11
13
16
7-1/8
9-1/8
11
13
16
3-1/8
3-1/8
continued on next page
Heavy-Duty Welded Universal Hangers – HWUH series
USP2173-111
Han
gers
1-800-328-5934 • www.USPconnectors.com 107
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Floor Uplift4
Ref. No. W H Qty Type Qty Type 100% 115% 125% 133%
6 NA21 4 10d 5165 5165 5165 1035
2 1/2 x 6 Emb. J-Bolt 4 10d 5165 5165 5165 10356 NA21 4 10d 5165 5165 5165 1035
2 1/2 x 6 Emb. J-Bolt 4 10d 5165 5165 5165 1035
6 NA21 4 10d 5165 5165 5165 10352 1/2 x 6 Emb. J-Bolt 4 10d 5165 5165 5165 1035
6 NA21 4 10d 5165 5165 5165 10352 1/2 x 6 Emb. J-Bolt 4 10d 5165 5165 5165 1035
6 NA21 4 10d 5165 5165 5165 10352 1/2 x 6 Emb. J-Bolt 4 10d 5165 5165 5165 1035
6 NA21 4 10d 5165 5165 5165 1035
2 1/2 x 6 Emb. J-Bolt 4 10d 5165 5165 5165 10356 NA21 4 10d 5165 5165 5165 1035
2 1/2 x 6 Emb. J-Bolt 4 10d 5165 5165 5165 10356 NA21 4 10d 5165 5165 5165 1035
2 1/2 x 6 Emb. J-Bolt 4 10d 5165 5165 5165 1035
6 NA21 4 10d 5165 5165 5165 10352 1/2 x 6 Emb. J-Bolt 4 10d 5165 5165 5165 1035
6 NA21 4 10d 5165 5165 5165 10352 1/2 x 6 Emb. J-Bolt 4 10d 5165 5165 5165 1035
6 NA21 4 10d 5165 5165 5165 1035
2 1/2 x 6 Emb. J-Bolt 4 10d 5165 5165 5165 10356 NA21 4 10d 5165 5165 5165 1035
2 1/2 x 6 Emb. J-Bolt 4 10d 5165 5165 5165 10356 NA21 4 10d 5165 5165 5165 1035
2 1/2 x 6 Emb. J-Bolt 4 10d 5165 5165 5165 1035
6 NA21 4 10d 5165 5165 5165 10352 1/2 x 6 Emb. J-Bolt 4 10d 5165 5165 5165 1035
6 NA21 4 10d 5165 5165 5165 10352 1/2 x 6 Emb. J-Bolt 4 10d 5165 5165 5165 1035
6 NA21 4 10d 5165 5165 5165 10352 1/2 x 6 Emb. J-Bolt 4 10d 5165 5165 5165 1035
6 NA21 4 10d 5165 5165 5165 1035
2 1/2 x 6 Emb. J-Bolt 4 10d 5165 5165 5165 10356 NA21 4 10d 5165 5165 5165 1035
2 1/2 x 6 Emb. J-Bolt 4 10d 5165 5165 5165 1035
1) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 2) NA21 nails are 6 gauge (0.192˝ diameter) by 1-3/4˝ long and are included with 4x, 6x, and 8x HWUH hangers.
4) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted.
L1, F17
CodeRef.
3) Minimum nail embedment shall be 1-1/2˝ for 10d nails.
HWUH46 -- -- 3-9/16 5-3/8
4 x 8 HWUH48
4 x 6
4 x 10 HWUH410
-- --
Fastener Schedule1,3
Header Joist
-- --
4 x 12 HWUH412 -- --
4 x 14 HWUH414 -- --
4 x 16 HWUH416 -- --
6 x 6 HWUH66 -- --
6 x 8 HWUH68 -- --
6 x 10 HWUH610 -- --
6 x 12 HWUH612 -- --
6 x 14 HWUH614 -- --
6 x 16 HWUH616 -- --
8 x 6 HWUH86 -- --
8 x 8 HWUH88 -- --
8 x 10 HWUH810 -- --
8 x 12 HWUH812 -- --
8 x 14 HWUH814 -- --
8 x 16 HWUH816 -- --
7-1/8
9-1/8
Dimensions
9-1/8
11
13
11
13
16
5-3/8
16
3-9/16
3-9/16
3-9/16
3-9/16
3-9/16
5-1/2
5-1/2
5-1/2
7-1/8
7-1/2
5-1/2
5-1/2
5-1/2
7-1/2
7-1/2
5-3/8
7-1/8
9-1/8
11
13
16
7-1/2
7-1/2
7-1/2
Allowable Loads (Lbs.)
DF-L / SP
Beam/Joist Size
USPStock No.
Roof
Option Skewed 1,3 Sloped Seat2,3 Sloped / Skewed1,2,3Top Flange Offset Saddle
Range 1˚ to 45˚ 1˚ to 45˚ See Sloped Seat and Skewed -- --
1) Skewed hangers with skews greater than 15° may have all joist nailing on outside flange. 2) Sloped or sloped / skewed hangers with slopes greater than 15° may have additional joist nails. 3) All sloped, skewed, or combinations require bevel cut on joist in all applications.
-- --
AllowableLoads
Ordering
100% of table load
Add SK, angle required,and right (R)or left (L),
to product number.Ex. HWUH410-SK45R
100% of table load 100% of table load
Hanger Width3-1/2˝ or less
3-9/16˝ to 5-1/2˝5-9/16˝ to 7-1/2˝
Add SA,and saddlewidth required
to product number.Ex. HWUH410-SA=5-1/2˝
% of tableload:60%75%85%
Add SL,slope required,and up (U)or down (D),
to product number.Ex. HWUH410-SL30D
See Sloped Seat and Skewed.Ex. HWUH410-SK45RSL30D
Add OS,and right (R)or left (L),to product number.Ex. HWUH410-OSL
100% of table loadper side
Specialty Options Chart – refer to Specialty Options pages 194, 196-197 for additional details.
Heavy-Duty Welded Universal Hangers – HWUH series cont.
1-800-328-5934 • www.USPconnectors.com
Han
gers
1-800-328-5934 • www.USPconnectors.com108
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Masonry Hangers – MPH series
Typical MPHdouble ply installation
Typical MPHsingle ply installation
Install with (2) 16dduplex nails ingrouted cells
Install with (2) 16dduplex nails ingrouted cells
These hangers are designed to support standard lumber joists, I-Joists, or beams. Easy installation into concrete block walls makes theMPH an attractive alternative to fabricating seats in masonry (or attaching ledgers) to support joists or beams.
Materials: 12 gaugeFinish: USP primer
Options: All nominal lumber sizes are available forrough/full size lumber. See Specialty OptionsChart on page 109.
Codes: ESR-1781, FL13285, L.A. City RR 25843
Installation:• Use all specified fasteners. See Product Notes, page 11.• 16d duplex nails are not supplied with MPH hangers.• Place hanger into position on top of concrete block. Install (2) 16dduplex nails (8 gauge or 0.162˝ dia. x 31⁄2˝ double head) through thetop flange nail holes. Then continue laying the next course of block.• A minimum of one course shall be laid over hanger top flange and onecourse below hanger top flange. Courses adjacent to the top flangeshall be subsequently grouted.• These products do not provide uplift resistance.
Floor
Ref. No. W H L Qty Type Qty Type 100% 115% 125%
2 x 10 MPH210 WM210, WM29.25 12 1-9/16 9-1/4 7 2 16d duplex 2 10d x 1-1/2 2585 2620 2645
2 x 12 MPH212 WM211.25, WM212 12 1-9/16 11-1/4 7 2 16d duplex 2 10d x 1-1/2 2585 2620 2645
2 x 14 MPH214 WM214 12 1-9/16 13-1/8 7 2 16d duplex 2 10d x 1-1/2 2585 2620 2645 2 x 16 MPH216 WM216 12 1-9/16 15-1/8 7 2 16d duplex 2 10d x 1-1/2 2585 2620 2645
(2) 2 x 10 MPH210-2 WM210-2, WM29.25-2 12 3-1/8 9-1/4 7 2 16d duplex 2 10d 4280 4280 4280 (2) 2 x 12 MPH212-2 WM212-2 12 3-1/8 11-1/4 7 2 16d duplex 2 10d 4280 4280 4280
(2) 2 x 14 MPH214-2 WM214-2 12 3-1/8 13-1/8 7 2 16d duplex 2 10d 4280 4280 4280
(2) 2 x 16 MPH216-2 WM216-2 12 3-1/8 15-1/8 7 2 16d duplex 2 10d 4280 4280 4280 3 x 10 MPH310 WM310 12 2-9/16 9-1/4 7 2 16d duplex 2 10d x 1-1/2 3240 3240 3240
3 x 12 MPH312 WM312 12 2-9/16 11-1/4 7 2 16d duplex 2 10d x 1-1/2 3240 3240 3240
3 x 14 MPH314 WM314 12 2-9/16 13-1/8 7 2 16d duplex 2 10d x 1-1/2 3240 3240 3240 3 x 16 MPH316 WM316 12 2-9/16 15-1/8 7 2 16d duplex 2 10d x 1-1/2 3240 3240 3240
4 x 10 MPH410 WM410 12 3-9/16 9-1/4 7 2 16d duplex 2 10d 4280 4280 4280 4 x 12 MPH412 WM412 12 3-9/16 11-1/4 7 2 16d duplex 2 10d 4280 4280 4280
4 x 14 MPH414 WM414 12 3-9/16 13-1/8 7 2 16d duplex 2 10d 4280 4280 4280
4 x 16 MPH416 WM416 12 3-9/16 15-1/8 7 2 16d duplex 2 10d 4280 4280 4280 6 x 10 MPH610 WM610 12 5-9/16 9-1/4 7 2 16d duplex 2 10d 4280 4280 4280
1) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 2) Masonry compressive strength shall be minimum 1500 psi. 3) Duplex nails are No. 8 wire gauge (0.162˝ diameter) and 3-1/2˝ long, double headed nails and shall be installed in grouted cells in accordance to manufacturer's installation specifications. 4) Minimum nail embedment shall be 1-1/2˝ for 10d nails.
CodeRef.
5,F30, R5
Beam/Joist Size
USPStock No.
SteelGauge
Dimensions Allowable Loads (Lbs.)2
Roof
Masonry Joist
Fastener Schedule1,3,4
DF-L / SP
continued on next page
MPH
H
W
3 3/4˝
2 1/2˝
L
USP2173-111
Han
gers
1-800-328-5934 • www.USPconnectors.com 109
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Option Skewed1 Sloped Seat2 Sloped / Skewed1,2Top Flange Offset
Range 1˚ to 60˚ 1˚ to 45˚ See Sloped Seat and Skewed
1) Skewed hangers with skews greater than 15° may have all joist nailing on outside flange. 2) Sloped or sloped / skewed hangers with slopes greater than 15° may have additional joist nails.
See Sloped Seat and Skewed.Ex. MPH210-SK45RSL30D
Add OS,andright (R)or left (L),to product number.Ex. MPH210-OSL
100% of table load 100% of table load
Ordering
100% of table load
Add SK,angle required,and right (R)or left (L),
to product number.Ex. MPH210-SK45R
Add SL,slope required,and up (U)or down (D),
to product number.Ex. MPH210-SL30D
Hanger Width3-1/2˝ or less
3-9/16˝ to 5-1/2˝5-9/16˝ to 7-1/2˝
% of table load:60%75%85%
-- --
AllowableLoads
Floor
Ref. No. W H L Qty Type Qty Type 100% 115% 125%
3-1/8 x glulam MPH325 -- -- 12 3-1/4 specify 7 2 16d duplex 2 10d 4280 4280 4280
5-1/8 x glulam MPH525 -- -- 12 5-1/4 specify 7 2 16d duplex 2 10d 4280 4280 4280
1) Masonry compressive strength shall be minimum 1500 psi. 2) Duplex nails are No. 8 wire gauge (0.162˝ diameter) and 3-1/2˝ long, double headed nails and shall be installed in grouted cells in accordance to manufacturer's installation specifications. 3) Minimum nail embedment shall be 1-1/2˝ for 10d nails.
CodeRef.
5, F30,R5
Fastener Schedule1,3
Masonry
Allowable Loads (Lbs.)1
Joist
Roof
DF-L / SP
Beam/Joist Size
USPStock No.
SteelGauge
Dimensions
Glulam sizes
Specialty Options Chart – refer to Specialty Options pages 194, 196 to 197 for additional details.
Floor Uplift1 Floor Uplift1
Ref. No. W Qty Qty Type 100% 115% 125% 160% 100% 115% 125% 160%
UMH358 MBHU3.56/16KT, MBHU3.56/18KT
3-5/8
UMH458 -- -- 4-5/8
UMH538 -- -- 5-3/8
UMH558 MBHU5.50/16KT, MBHU5.5018KT
5-5/8
UMH718 -- -- 7-1/8
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) Fasten UMH hanger to concrete structure with two 3/4˝ dia. Powers Fasteners Wedge-Bolts® or equal with 5˝ minimum embedment. Bolts shall be installed in masonry with grouted cells in accordance with manufacturer's installation specifications. 3) Bolts must conform to ASTM A 307 or better. 4) Minimum nail embedment shall be 1-5/8˝ for 16d nails. New products or updated product information are designated in bold font.
CodeRef.
F25, D148152 16d 3550 6380 6380 63803550 3550 3550
USPStock No.
SteelGauge
Roof
3 3/4 16
BoltDia.
Roof
Fastener Schedule DF-L / SP Allowable Loads (Lbs.)
Masonry - 2500 psi Cast in Place Concrete - 3000 psiHeader2,3
Joist4
Bond beam with(1) #5 rebar continuous
2 3/4˝ bolts. (see footnote 2)
3 1/2˝ Min. joist bearing
5 1/4˝ Min.edge distance
Typical UMHinstallation
15 1/2˝
5˝W
UMH
Universal Masonry Hangers – UMH series
A versatile solution for hanging beams from masonry walls.Face mount design allows hanger to be used with beamheights from 16˝ to 24˝. Available in a variety of widthsfor solid sawn, glulam, or engineered lumber beams.
Materials: 1/4˝ steelFinish: USP primerCodes: Dade County, FL 04-1122.03, FL5631
Installation:• Use all specified fasteners. See Product Notes, page 11.• Fully grouted and reinforced concrete block or cast-in-placeconcrete with a minimum of (1) #5 rebar continuous tofooting with standard hook at bolt locations.• Minimum joist bearing length is 31/2˝.
Masonry Hangers – MPH series continued
1-800-328-5934 • www.USPconnectors.com
Floor
Ref. No. W H L Qty Type Qty Type 100% 115% 125%
2 x 10 MPH210 WM210, WM29.25 12 1-9/16 9-1/4 7 2 16d duplex 2 10d x 1-1/2 2585 2620 2645
2 x 12 MPH212 WM211.25, WM212 12 1-9/16 11-1/4 7 2 16d duplex 2 10d x 1-1/2 2585 2620 2645
2 x 14 MPH214 WM214 12 1-9/16 13-1/8 7 2 16d duplex 2 10d x 1-1/2 2585 2620 2645 2 x 16 MPH216 WM216 12 1-9/16 15-1/8 7 2 16d duplex 2 10d x 1-1/2 2585 2620 2645
(2) 2 x 10 MPH210-2 WM210-2, WM29.25-2 12 3-1/8 9-1/4 7 2 16d duplex 2 10d 4280 4280 4280 (2) 2 x 12 MPH212-2 WM212-2 12 3-1/8 11-1/4 7 2 16d duplex 2 10d 4280 4280 4280
(2) 2 x 14 MPH214-2 WM214-2 12 3-1/8 13-1/8 7 2 16d duplex 2 10d 4280 4280 4280
(2) 2 x 16 MPH216-2 WM216-2 12 3-1/8 15-1/8 7 2 16d duplex 2 10d 4280 4280 4280 3 x 10 MPH310 WM310 12 2-9/16 9-1/4 7 2 16d duplex 2 10d x 1-1/2 3240 3240 3240
3 x 12 MPH312 WM312 12 2-9/16 11-1/4 7 2 16d duplex 2 10d x 1-1/2 3240 3240 3240
3 x 14 MPH314 WM314 12 2-9/16 13-1/8 7 2 16d duplex 2 10d x 1-1/2 3240 3240 3240 3 x 16 MPH316 WM316 12 2-9/16 15-1/8 7 2 16d duplex 2 10d x 1-1/2 3240 3240 3240
4 x 10 MPH410 WM410 12 3-9/16 9-1/4 7 2 16d duplex 2 10d 4280 4280 4280 4 x 12 MPH412 WM412 12 3-9/16 11-1/4 7 2 16d duplex 2 10d 4280 4280 4280
4 x 14 MPH414 WM414 12 3-9/16 13-1/8 7 2 16d duplex 2 10d 4280 4280 4280
4 x 16 MPH416 WM416 12 3-9/16 15-1/8 7 2 16d duplex 2 10d 4280 4280 4280 6 x 10 MPH610 WM610 12 5-9/16 9-1/4 7 2 16d duplex 2 10d 4280 4280 4280
1) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 2) Masonry compressive strength shall be minimum 1500 psi. 3) Duplex nails are No. 8 wire gauge (0.162˝ diameter) and 3-1/2˝ long, double headed nails and shall be installed in grouted cells in accordance to manufacturer's installation specifications. 4) Minimum nail embedment shall be 1-1/2˝ for 10d nails.
Han
gers
1-800-328-5934 • www.USPconnectors.com110
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com1-800-328-5934 • www.USPconnectors.com
Narrow Flange Masonry Hangers – NFM series
NFM – Standard design.
NFM_U – High uplift design.
Materials: See chartFinish: USP primerCodes: FL578, Dade County, FL 07-1003.10
Installation:• Use all specified fasteners. See Product Notes, page 11.• Designed for both concrete walls and grout-filled reinforced CMU walls.
Option Skewed1,2
Range 1˚ to 45˚
1) Skewed hangers with skews greater than 15° may have all joist nailing on outside flange. 2) Skewed hangers with skews greater than 15° require the joist end to be bevel cut.
Ordering
AllowableLoads
100% of table load
Add SK, angle required, and right (R) or left (L),to product number. Ex. NFM3-SK45R
Typical NFM45installation
NFM3
Floor Uplift
Ref. No. W H Qty Type Qty Type 100% 115% 125% 160%
NFM3X8 -- -- 3/8 7 3-1/8 7-1/4 1 1/2" J-Bolt 10 10d 7130 7130 7130 1720 F9, D8
NFM3X10 -- -- 3/8 7 3-1/8 9-1/4 1 1/2" J-Bolt 12 10d 7130 7130 7130 1720 F9, D8
NFM3X12 -- -- 3/8 7 3-1/8 11-1/4 1 1/2" J-Bolt 14 10d 7130 7130 7130 1720 F9, D8
NFM3 -- -- 3/8 7 3-3/8 11-3/4 1 1/2" J-Bolt 14 10d 7510 7510 7510 1720 F9, D8
NFM35X8 -- -- 3/8 7 3-5/8 7-1/4 1 1/2" J-Bolt 10 10d 7510 7510 7510 1720 F9, D8
NFM35X10 -- -- 3/8 7 3-5/8 9-1/4 1 1/2" J-Bolt 12 10d 7510 7510 7510 1720 F9, D8
NFM35X12 -- -- 3/8 7 3-5/8 11-1/4 1 1/2" J-Bolt 14 10d 7510 7510 7510 1720 F9, D8
NFM35X1178 -- -- 3/8 7 3-5/8 11-7/8 1 1/2" J-Bolt 14 10d 7510 7510 7510 1720 F9, D8
NFM35X16 -- -- 3/8 7 3-5/8 16 1 1/2" J-Bolt 14 10d 7510 7510 7510 1720 F9, D8
NFM35X18 -- -- 3/8 7 3-5/8 18 1 1/2" J-Bolt 14 10d 7510 7510 7510 1720 F9, D8
NFM6X1178 -- -- 3/8 7 5-5/8 11-7/8 1 1/2" J-Bolt 14 10d 7510 7510 7510 1720 F9, D8
NFM6X16 -- -- 3/8 7 5-5/8 16 1 1/2" J-Bolt 14 10d 7510 7510 7510 1720 F9, D8
NFM6X18 -- -- 3/8 7 5-5/8 18 1 1/2" J-Bolt 14 10d 7510 7510 7510 1720 F9, D8
NFM3X10U MBHA3.12/9.25 3/8 7 3-1/8 9-1/4 1 1/2" J-Bolt 5 1/2 7130 7130 7130 3165 F9, D8
NFM3X12U MBHA3.12/11.25 3/8 7 3-1/8 11-1/4 1 1/2" J-Bolt 5 1/2 7130 7130 7130 3165 F9, D8
NFM35X10U MBHA3.56/9.25 3/8 7 3-5/8 9-1/4 1 1/2" J-Bolt 5 1/2 7130 7130 7130 3165 F9, D8
NFM35X12U MBHA3.56/11.25 3/8 7 3-5/8 11-1/4 1 1/2" J-Bolt 5 1/2 7130 7130 7130 3165 F9, D8
NFM35X1178U MBHA3.56/11.88 3/8 7 3-5/8 11-7/8 1 1/2" J-Bolt 5 1/2 7130 7130 7130 3165 F9, D8
NFM35X14U MBHA3.56/14 3/8 7 3-5/8 14 1 1/2" J-Bolt 5 1/2 7130 7130 7130 3165 130
NFM35X16U MBHA3.56/16 3/8 7 3-5/8 16 1 1/2" J-Bolt 5 1/2 7130 7130 7130 3165 F9, D8
NFM35X18U MBHA3.56/18 3/8 7 3-5/8 18 1 1/2" J-Bolt 5 1/2 7130 7130 7130 3165 F9, D8
NFM6X10U MBHA5.50/9.25 3/8 7 5-5/8 9-1/4 1 1/2" J-Bolt 5 1/2 7130 7130 7130 3165 130
NFM6X12U MBHA5.50/11.25 3/8 7 5-5/8 11-1/4 1 1/2" J-Bolt 5 1/2 10310 10310 10310 3070 130
NFM6X1178U MBHA5.50/11.88 3/8 7 5-5/8 11-7/8 1 1/2" J-Bolt 5 1/2 10310 10310 10310 3070 F9, D8
NFM6X14U MBHA5.50/14 3/8 7 5-5/8 14 1 1/2" J-Bolt 5 1/2 10310 10310 10310 3070 130
NFM6X16U MBHA5.50/16 3/8 7 5-5/8 16 1 1/2" J-Bolt 5 1/2 10310 10310 10310 3070 F9, D8
NFM6X18U MBHA5.50/18 3/8 7 5-5/8 18 1 1/2" J-Bolt 5 1/2 10310 10310 10310 3070 F9, D8
1) Allowable loads are based on 2500 psi concrete or masonry. 2) Design loads are governed by test ultimate loads with a safety factor of three. 3) J-Bolt shall be cast-in-place and have a minimum 6˝ embedment and not less than 4˝ from the edge of concrete. 4) In addition to the J-Bolt, "U" models also require a 3/4˝ dia. ITW Ramset/Redhead Dyna Bolt sleeve anchor or equal with minimum 5˝ embedment depth installed in the face. Bolt shall be installed in accordance with installation specifications provided by ITW Ramset. 5) Bolts shall conform to ASTM A 307 or better. 6) Minimum nail embedment shall be 1-1/2˝ for 10d nails.
CodeRef.
DimensionsSteel Gauge Allowable Loads (Lbs.)1,2Fastener Schedule
DF-L / SPHeader3,4
Joist5,6
USPStock No.
RoofTopFlange
U-Strap
Typical NFM45Uinstallation
H
W
5 1/2˝
3 1/2˝
NFM Specialty Options Chart – refer to Specialty Optionspages 194, 196 to 197 for additional details.
1-800-328-5934 • www.USPconnectors.com
USP2173-111
EW
PH
an
gers
1-800-328-5934 • www.USPconnectors.com 111
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®EWP Hangers
Supported Member Supporting Member
HangerType
USPSeries
SteelGauge
Fac
e M
ount
Top
Mou
nt
Slo
ped
/ Ske
wed
For
med
Wel
ded
I-J
oist
LVL
, LSL
, PSL
Tru
ss
Glu
lam
Dim
ensi
onal
Woo
d
I-J
oist
LVL
, LSL
, PSL
Tru
ss
Glu
lam
Mas
onry
LVL
DF-
L / S
P
Mas
onry
18 • • • • • • 910 - 2,735 910 - 2,735
16 • • • • • • 1,390 - 2,785 1,390 - 2,785
12 • • • • • • 2,285 - 3 050 2,285 - 3 050
HUS 16 • • • • • • 5,310 5,310
HD 14 • • • • • • 1,690 - 4,230 1,690 - 4,230
HDQ 14 • • • • • • 3,010 - 5,265 3,010 - 5,265
14 • • • • • • 5,360 - 7,045 5,360 - 7,045
12 • • • • • • 5,660 - 8,415 5,660 - 8,415
THDH 12 • • • • • • 8,260 - 11,645 8,260 - 11,645
TFL 18 • • • • • 1,645 1,600
18 • • • • • • 1,345 - 2,715 1,005 - 2,715
16 • • • • • • 1,030 - 2,330 1,030 - 2,700
12 • • • • • • 2,330 - 3,535 3,665 - 4,770
TFI 16 • • • • • 2,560 - 3,245 2,560 - 3,245
BPH 12 • • • • • • 3,120 - 3,485 2,705 - 3,485
MPH 12 • • • • • 2,585 - 4,280
PHM7 - Top Flange,
10 - Stirrup• • • • 3,535 - 3,745 2,865 - 3,390
PHXU 7 • • • • 4,420 - 6,650 4,425 - 5,285
HLBH 7 • • • • 10,225 - 10,620 9,600
12 • • • • • 2,190 - 6,570 2,190 - 6,570
7 • • • • • 6,500 - 12,000 6,500 - 12,000
KLEG 7 • • • • • • 3,540 - 11,940 3,540 - 11,940
KMEG 7 • • • • • • 5,285 - 12,635 5,285 - 12,635
KEG1/4˝ - Top Flange,
7 - Stirrup• • • • • • 9,215 - 21,545 9,215 - 21,545
KHHB 7 • • • • • 4,885 - 5,275 4,885 - 5,275
KGB 7 • • • • • 6,460 - 6.915 6,460 - 6.915
KHGB 7 • • • • • 7,530 - 8,050 7,530 - 8,050
KGLT3 - Top Flange,
7 - Stirrup• • • • • 7,545 7,545
KHGLT3 - Top Flange,
7 - Stirrup• • • • • 10,150 - 13,400 10,150 - 13,400
KGLS3 - Top Flange,
7 - Stirrup• • • • • 10,275 - 20,425 10,275 - 20,425
KHGLS3 - Top Flange,
7 - Stirrup • • • • • 20,685 - 20,985 20,685 - 20,985
KGLST3 - Top Flange,
7 - Stirrup• • • • • 12,900 - 26,095 12,900 - 26,095
KHGLST3 - Top Flange,
7 - Stirrup• • • • • 19,250 - 26,585 19,250 - 26,585
7 • • • • 10,505 - 44,100 10,505 - 44,100
3 • • • • 22,040 - 54,180 22,040 - 54,180
7 • • • • 9,950 - 14,500 9,950 - 14,500
3 • • • • 20,145 20,145
18 • • • • • • • 685 - 1,140 685 - 1,140
16 • • • • • • • 1,825 - 2,485 1,825 - 2,485
1) KHCST allowable loads are based on 160% load duration. • Represents common applications and product configurations. Consult USP for additional applications and/or optional product configurations.
LSSHSlope / Skew
TopMount
FaceMount
KHC
KHCST1
Style
Glulam
100% Allowable Loads (Lbs.) Range
THF
THD
THO
GHF
Header Material
EWP Hanger Selector Guide
EW
PH
an
gers
1-800-328-5934 • www.USPconnectors.com112
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
TMP TMPH
HLBH
THF HD
THD
HDQ-IF
THDHHUS
TFL
PHM
THO
PHXU MPH
TFI
EWP Installation Guide . . Pages 114-115
Face Mount Hangers. . . . . Pages 116-122• THF SeriesLight capacity face mount hanger for I-Joists.
• HD SeriesMedium capacity hanger for LVL, LSL, and PSL beams.
• HDQ-IF SeriesInverted flange medium capacity hanger for LVL, LSL, and PSL beams.
• HUS SeriesMedium capacity hanger for LVL, LSL, and PSL beams with deep seat.
• THD SeriesMedium-to-heavy capacity hanger for LVL, LSL, and PSL beams.
• THDH SeriesHeavy capacity hanger for LVL, LSL, and PSL beams.
Top Mount Hangers . . . . . Pages 123-134• TFL SeriesLight capacity top mount I-Joist hanger.
• THO SeriesLight-to-medium capacity top mount hanger.
• TFI SeriesMedium capacity I-Joist hanger.
• BPH SeriesMedium capacity top mount hanger for LVL, LSL, and PSL beams.
• HLBH SeriesHeavy capacity hanger for LVL, LSL, and PSL beams.
• PHM SeriesMedium capacity welded hanger for LVL, LSL, and PSL beams with7 gauge top flanges.
• PHXU SeriesMedium capacity formed hanger for LVL, LSL, and PSL beams withuplift capacity.
• MPH SeriesMedium capacity masonry hanger for I-Joists, LVL, LSL, andPSL beams.
Adjustable Rafter-to-Plate Connectors . . . . . . . . . . . . . . . . . . Page 135• TMP SeriesAdjustable for pitches from 1/12 to 6/12.
• TMPH SeriesAdjustable for pitches from 6/12 to 14/12.
BPH
EWP Hangers
continued on next page
USP2173-111
1-800-328-5934 • www.USPconnectors.com 113
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
Slope/Skew Hangers . . . . . . . . . . Page 136• LSSH SeriesField adjustable slope and skew hanger.
Glulam Hangers . . . . . . . . Pages 137-143• GHF SeriesFace mount glulam hanger.
• KEG, KLEG, & KMEG SeriesTop flange glulam hanger with bolts.
• KGB, KHGB, & KHHB SeriesTop flange glulam hanger with wood screws.
• KGLT & KHGLT SeriesHeavy capacity top flange glulam hanger.
• KGLS, KGLST, KHGLS, & KHGLST SeriesGlulam saddle hanger.
• KHC SeriesGlulam hinge connector.
• KHCST SeriesGlulam seismic strap.
GHF
KGLT KGLS KHC
KHHBKLEG
KHCST
EWP Hangers
LSSH
EW
PH
an
gers
EW
PH
an
gers
1-800-328-5934 • www.USPconnectors.com114
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®Wood I-Joist Installation to Wood
Sloped I-JoistsUse sloped seat hangers and beveled web stiffeners whenever the slope exceeds the following: 1/2:12 for seatbearing lengths of 21/2˝ or less; 3/8:12 for bearing lengthsbetween 21/2˝ and 31/2˝; and 1/4:12 for bearing lengths inexcess of 31/2˝.
Multiple I-Joist PlysFasten together multiple plys of wood I-Joists, inaccordance with the manufacturer’s installation guidelines, suchthat the joists act as a single unit.
I-Joist RotationIt may be necessary to install straps, blocking, or sheathingto restrain torsional rotation of a supporting wood I-Joist whenusing top mount I-Joist hangers.
FastenersInstall only the specified nails. The flanges of woodI-Joists may split if larger diameter nails or longer nails areinstalled. Do not install nails larger than 16d common wire nails(0.162˝ diameter) into the web stiffeners in the wood I-Joist.
Backer BlocksPattern the nails used to install backer blocks or web stiffeners in wood I-Joists to avoid splitting the block. The nailpattern should be sufficiently spaced to avoid the same grainline, particularly with solid sawn backer blocks. Backer blocksmust be installed on wood I-Joist acting as the header, or supporting member. Install in accordance with the I-Joist manufacturer’s installation guidelines. The nails used to installhangers mounted to an I-Joist header must penetrate throughthe web and into the backer block on the opposite side.
The thickness of the hanger metal and nail heads on top mount hangers must be evaluated for the effect onsubsequent sheathing. Ensure that the top mount hanger is installed so the flanges of the hanger are notover-spread which tends to elevate the supported I-Joist causing uneven floor surfaces and squeaking. Similarly, ensure thatthe hanger is installed plumb such that the face flanges of the hanger are mounted firmly against thewide-face surface of the header.
Flush framing Hanger over-spread Hanger not plumb
Common Nailing Errors
Wrong AngleWhen a nail is driven into the bottom flange of the wood I-Joist parallel to the glue lines, separation of veneers canoccur which substantially reduces the design loads of theconnection.
Nail Too LongWhen using nails longer than USP’s recommended nails,bottom flange splitting may occur. Also, this can raise thewood I-Joist off the seat, resulting in uneven surfaces andsqueaky floors along with reduced allowable loads.
Top Flange Hangers
Correct Slant Nail Installation
Always securewood I-Joist using10d x 11 ⁄ 2˝nail driven at a 30° to45° angleand firmly seated
USP2173-111
EW
PH
an
gers
1-800-328-5934 • www.USPconnectors.com 115
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®Support Height & Lateral Stability
Avoid direct contact betweenhangers and steel beams, which
may cause squeaks
1/4˝Max.
Resist lateral movement
Correct Hanger Attachment to NailerA nailer or sill plate is considered to be any wood member attached to a steel beam,concrete block wall, concrete stem wall, or other structure unsuitable for nailing, whichis used as a nailing surface for top mount hangers to hold beams or joists.
Nailer Sized CorrectlyTop flange of hanger is fully supported and recommended nails have fullpenetration into nailer, resulting in a carried member hanging safely at the properheight.
The nailer must be sized to fit the support width as shown and be of sufficient thicknessto satisfy recommended top flange nailing requirements. A design professional mustspecify nailer attachment to steel beams.
1/8˝ maximum gapWeb stiffener
60% min. ofjoist depth
Joistdepth
1/4˝ Max.
Too Thin
Top flange nailing cannot fullypenetrate nailer, causing reducedallowable loads. Never usehangers which require multiple facenails since the allowable loads aredependent on all nail holes beingused.
Hangers for joists without web stiffeners must support theI-Joist’s top flange and provide lateral resistance with nomore than 1⁄8˝ horizontal deflection.
Hangers for joists with web stiffeners must support a minimum of 60% of joist depth or potential joist rotation mustbe addressed.
(Top flange support requirements can be verified in this sections charts under the Web Stiffener Reqd. column.)
Too Narrow
Top flange not fully supported cancause nail breakout. Or, by fully supporting top flange, hanger is tilted back, causing lifting of carriedmember which results in unevensurfaces and squeaky floors.
Too Wide
Loading can cause cross grainbreaking of nailer. The recommended nailer overhangis 1⁄4˝ maximum per side.
Nailer Installations
Wrong Nailer Size Causes Component Failure
Correct Attachment
EW
PH
an
gers
1-800-328-5934 • www.USPconnectors.com116
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
H
W2˝
Additional diamondnail holes formaximum nailingStandard roundnail holes forminimum nailing
Raised dimple allows30˚ to 45˚ nailing
H
DW
THF single THF double
Face Mount I-Joist Hangers – THF series
Designed to support LVL, LSL, and PSL beams and headers in medium load conditions.
Materials: See EWP Face Mount Hangers charts, pages 120-122.Finish: G90 galvanizing
Options: See Specialty Options chart.Codes: ESR-1781, FL815, L.A. City RR 25843, FL13285
Installation:• Use all specified fasteners. See Product Notes, page 11.• Drive bend line nails into header at 45° to achieve listed loads.
Option 4 Skewed 1,3 Sloped Seat2,3 Sloped / Skewed1,2,3Inverted Flange
1) Skewed hangers with skews greater than 15° may have all joist nailing on outside flange. 2) Sloped or sloped / skewed hangers with slopes greater than 15° may have additional joist nails. 3) All sloped, skewed, or combinations require bevel cut on joist in all applications and web stiffeners with I-joists. Hangers for square-cut joists are available as a Custom. Further reductions in allowable loads may apply. 4) Modifications of HD hangers may be manufactured as hot rolled, welded, or primed. New products or updated product information are designated in bold font.
1˚ to 67-1/2˚when width is 1-3/4˝ or less.
1˚ to 50˚ on all others.1˚ to 45˚ See Sloped Seat and Skewed
100% of table load80% of table load.
75% of uplift load on skewsgreater than 15˚.
Range
Ordering
AllowableLoads
Not available inwidths less than 2-1/4˝
100% of table load.75% of uplift load on skews
greater than 15˚.
100% of table load.65% of table load whennailing into the supportmembers end grain.
See Sloped Seat and Skewed.Ex. HD410-SK45RSL30D
Add IFto product number.
Ex. HD410IF
Add SK,angle required,and right (R) or left (L),
to product number.Ex. HD410-SK45R
Add SL,slope required,and up (U) or down (D),
to product number.Ex. HD410-SL30D
Typical THF I-Joist to Joist
installation
W
Bend linenailing
D
H
Designed to provide lateral support for the top chords of I-Joists in depths upto 16˝. Eliminates the need for web stiffeners in most applications (see Web Stiffener Reqd. column in EWP Face Mount HangerChart for specific applications).
Materials: See EWP Face Mount Hangers charts, pages 119-120.Finish: G90 galvanizing
Options: See Specialty Options chart.Codes: ESR-1781, FL815, L.A. City RR 25843, FL13285
Patents: #5,564,248 (all models except doubles)
Installation:• Use all specified fasteners. See Product Notes, page 11.• Install 10d x 11 ⁄ 2˝ nails into joist through raised dimple at 30° to 45° angle.• THF Min – Fill all round nail holes.• THF Max – Fill all round and diamond holes.• Uplift capacity for THF single ply hangers installed without joist nails = 85lbs. Refer to THO, TFL, & THF Single Ply I-Joist Hangers Technical Bulletin– USP1040.
Face Mount Hangers – HD series
Typical THF double I-Joist to LVLinstallation
Option Skewed 1,3 Sloped Seat2,3 Sloped / Skewed1,2,3Inverted Flange
1) Skewed hangers with skews greater than 15° may have all joist nailing on outside flange. 2) Sloped or sloped / skewed hangers with slopes greater than 15° may have additional joist nails. 3) All sloped, skewed, or combinations require bevel cut on joist in all applications. 4) Modifications to THF hangers do not feature seat cleats.
Add SL, slope required,and up (U)or down (D),
to product number.Example: THF23925-SL30D
See Sloped Seat andSkewed
Example:THF23925-SK45RSL30D
Add IF,to product number.
Example: THF23925IF
1˚ to 67-1/2˚when width is 1-3/4˝ or less.
1˚ to 50˚ on all others.
100% of table load
Not available inwidths less than 2-1/4˝
1˚ to 45˚
100% of table load.65% of table load whennailing into the supportmembers end grain.
80% of table load.75% of uplift load on
skews greater than 15˚.
See Sloped Seat andSkewed
Range
AllowableLoads
Ordering
Add SK, angle required,and right (R)or left (L),
to product number.Example: THF23925-SK45R
100% of table load.75% of uplift load on
skews greater than 15˚.
Typical HDinstallation
Drive bend line nailsinto header at 45° toachieve listed loads.
Typical HDbend line nail installation
Specialty Options Chart – refer to SpecialtyOptions pages 194 to 195 for additional details.
Specialty Options Chart – refer to Specialty Options pages 194 to 195 for additional details.
Seat Cleat®helps lock
I-Joist intoplace for
positive seatingand nailing
ease.
Raised Dimplenail holes allow
30° to 45°nailing into
I-Joist bottomflange.
HD
USP2173-111
Face Mount Hangers – HDQ-IF seriesE
WP
Han
gers
1-800-328-5934 • www.USPconnectors.com 117
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
H
3˝W
HDQ hangers are heavy-duty face mount hangers thatcan be used to support LVL, LSL and PSL beams andheaders.
Materials: 14 gaugeFinish: G90 galvanizing
Installation:• Use all specified fasteners. See Product Notes, page 11.• WS15 and WS3 Wood Screws are supplied with HDQhangers.
Typical HDQinstallation
Up to 3/4˝ gap
HDQ
Face Mount Hangers – HUS series
H
2˝
3˝
Raised dimple allows30˚ to 45˚nailing
W
Typical HUSinstallation
HUS
Designed for medium load conditions. Extended 3˝ deep seat provides extra truss bearing.
Materials: 16 gaugeFinish: G90 galvanizing
Options: See Specialty Options chart.Codes: ESR-1881, FL9835, FL821
Dade County FL 06-0921.05,L.A. City RR 25779
Installation:• Use all specified fasteners. See Product Notes, page 11.• Joist nails must be driven at a 30° to 45° angle throughthe joist into the header to achieve listed loads.
Option Inverted Flange
Range Not available in widths less than 2-1/4˝
Ordering Add IFto product number. Example: HUS410IF
AllowableLoads
100% of table load.65% of table load when nailing into
the support members end grain.
Specialty Options Chart – refer to SpecialtyOptions pages 194 to 195 for additional details.
Typical HUS double shear installation
Drive joist nails intoheader at 30° to 45° to
achieve listed loads.
EW
PH
an
gers
1-800-328-5934 • www.USPconnectors.com118
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®Face Mount Hangers – THD & THDH series
THD – Medium capacity hanger for LVL, LSL, and PSL beams.
THDH – Heavy capacity hanger for LVL, LSL, and PSL beams.
Materials: See EWP Face Mount Hangers charts, pages 121-122.Finish: G90 galvanizing
Options: Rough/ Full sizes available for THD series. THD hangers with widths greater than 3˝ can have one flange inverted with no load reduction. Specify left (L) or (R) flange. See Specialty Options chart.
Codes: ESR-1781, ESR-1881, FL821, FL9835, FL13285Dade County FL 06-0921.05 , L.A. City RR 25779, L.A. City RR 25843
Installation:• Use all specified fasteners. See Product Notes, page 11.• THD – Drive bend line nails into header at 45° to achieve listed loads.• THDH – Drive joist nails into header at 30° to 45° to achieve listed loads.
DW
2 1/2˝
Raiseddimple allows30˚ to 45˚
nailing
THDH26-2
Left flange
Right flange
D
3˝
W
THD doubleor larger
Option USP Series Skewed1,3,4 Sloped Seat2,3,4 Sloped / Skewed1,2,3,4Inverted Flange
THDH 1˚ to 45˚ 1˚ to 45˚ See Sloped Seat and Skewed N/A
THDH N/A
1) Skewed hangers with skews greater than 15° may have all joist nailing on outside flange. All skewed THDH hangers have nails on one side only. 2) Sloped or sloped / skewed hangers with slopes greater than 15° may have additional joist nails. 3) THDH models - All sloped, skewed, or combinations require bevel cut on joist in all applications. 4) THD models - All sloped, skewed, or combinations require bevel cut or square cut on joist in all applications.
Add 1IF,one flange,right (R)and left (L),
Example: THD4101IFR
65% of table load
N/A52% of table load52% of table load.
50% of table uplift load.
Not available in widthsless than 3˝. Widths greater
can have one flange inverted.See Sloped Seat and Skewed
See Sloped Seat and SkewedExample:
THDH410-SK45RSL30D
Range
AllowableLoads
85% of table load.50% of table uplift load.
1˚ to 45˚
Ordering
100% of table load.65% of table load whennailing into the supportmembers end grain.
85% of table load
THD
Add SK, angle required,and right (R)or left (L),
to product number.Example: THDH410-SK45R
Add SL, slope required,and up (U)or down (D),
to product number.Example: THDH410-SL30D
1˚ to 45˚
65% of table load
THD
THD
THDH
Typical THDinstallation
Typical THDH double shear installation
Drive joist nails intoheader at 30° to 45° to
achieve listed loads.
Specialty Options Chart – refer to Specialty Options pages 194 to 195 for additional details.
Drive bend line nailsinto header at 45° toachieve listed loads.
Typical THDbend line nail installation
Some modeldesigns may
vary fromillustration
shown
H
DW
THD single
USP2173-111
EW
PH
an
gers
1-800-328-5934 • www.USPconnectors.com 119
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®EWP Face Mount Hangers – I-Joist Charts
continued on next page
Dimensions
Uplift2 Uplift2
Code
Joist Size Ref. No. W H D Qty Type Qty Type 100% 115% 125% 160% 100% 115% 125% 160% Ref.
THF15925 Min IUS1.56/9.5 8 10d 2 10d x 1-1/2 910 1050 1140 280 785 900 980 235
THF15925 Max IUT29, MIU1.56/9
12 10d 2 10d x 1-1/2 1370 1575 1710 280 1175 1350 1470 235
THF15112 Min IUS1.56/11.88 8 10d 2 10d x 1-1/2 910 1050 1140 280 785 900 980 235
THF15112 Max IUT211, MIU1.56/11
16 10d 2 10d x 1-1/2 1825 2100 2155 280 1470 1500 1520 235
THF15140 Min -- -- 12 10d 2 10d x 1-1/2 1370 1575 1710 280 1175 1350 1470 235
THF15140 Max IUT214 20 10d 2 10d x 1-1/2 2100 2135 2155 280 1470 1500 1520 235
THF16925 Min -- -- 8 10d 2 10d x 1-1/2 910 1050 1140 280 785 900 980 235
THF16925 Max IUT1.68/9 12 10d 2 10d x 1-1/2 1370 1575 1710 280 1175 1350 1470 235
THF16112 Min -- -- 8 10d 2 10d x 1-1/2 910 1050 1140 280 785 900 980 235
THF16112 Max IUT1.68/11 16 10d 2 10d x 1-1/2 1825 2100 2280 280 1570 1605 1625 235
THF16140 Min -- -- 12 10d 2 10d x 1-1/2 1370 1575 1710 280 1175 1350 1470 235
THF16140 Max IUT1.68/14 20 10d 2 10d x 1-1/2 2255 2290 2310 280 1575 1605 1625 235
THF17925 Min IUS1.81/9.5 8 10d 2 10d x 1-1/2 910 1050 1140 280 785 900 980 235
THF17925 Max IUT9 12 10d 2 10d x 1-1/2 1370 1575 1710 280 1175 1350 1470 235
THF17112 Min IUS1.81/11.88 8 10d 2 10d x 1-1/2 910 1050 1140 280 785 900 980 235
THF17112 Max IUT11 16 10d 2 10d x 1-1/2 1825 2100 2280 280 1570 1710 1730 235
THF17140 Min IUS1.81/14 12 10d 2 10d x 1-1/2 1370 1575 1710 280 1175 1350 1470 235
THF17140 Max IUT14 20 10d 2 10d x 1-1/2 2280 2445 2470 280 1680 1710 1730 235
1-3/4 x 16 THF17157 IUS1.81/16 -- 18 1-13/16 15-3/4 3-1/2 24 10d 2 10d x 1-1/2 2735 3145 3310 280 2350 2705 2780 235
THF20925 Min IUS2.06/9.5 8 10d 2 10d x 1-1/2 910 1050 1140 280 785 900 980 235
THF20925 Max IUT2.06/9 12 10d 2 10d x 1-1/2 1370 1575 1710 280 1175 1350 1470 235
THF20112 Min IUS2.06/11.88 8 10d 2 10d x 1-1/2 910 1050 1140 280 785 900 980 235
THF20112 Max IUT2.06/11 16 10d 2 10d x 1-1/2 1825 2100 2280 280 1570 1805 1945 235
THF20140 Min IUS2.06/14 12 10d 2 10d x 1-1/2 1370 1575 1710 280 1175 1350 1470 235
THF20140 Max IUT2.06/14 20 10d 2 10d x 1-1/2 2280 2470 2470 280 1895 1925 1945 235
2 - 2-1/8 x 16 THF20157 IUS2.06/16, IUT2.06/16
-- 18 2-1/8 15-3/4 3-3/8 24 10d 2 10d x 1-1/2 2735 3145 3310 280 2350 2705 2780 235
2-5/16 x 9-1/2 THF23925
HU359, IUS2.37/9.5, IUT3510, MIU2.37/9, U3510/14
-- 18 2-5/16 9-3/16 2-1/2 12 10d 2 10d x 1-1/2 1370 1575 1710 175 1175 1350 1470 1505,
F30,R5
2-5/16 x 11-7/8 THF23118
HU3511, IUS2.37/11.88, IUT3512, MIU2.37/11
-- 18 2-5/16 11-3/16 2-1/2 14 10d 2 10d x 1-1/2 1595 1835 1995 360 1370 1580 1715 310
2-5/16 x 14 THF23140
HU3514, IUS2.37/14, IUT3514, MIU2.37/14
-- 16 2-5/16 13-1/2 2-1/2 18 10d 2 10d x 1-1/2 2090 2400 2610 360 1800 2070 2250 310
2-5/16 x 16 THF23160
HU3516/22, IUS2.37/16, IUT3516, MIU2.37/16
-- 16 2-5/16 15-9/16 2-1/2 22 10d 2 10d x 1-1/2 2550 2935 3035 360 2200 2530 2550 310
2-5/16 x 18 - 28 THF23180 HU3524/30, MIU2.37/18, MIU2.37/20
x 16 2-5/16 17-1/8 2-1/2 24 10d 8 10d x 1-1/2 2785 3200 3480 1295 2400 2760 3000 1085
2-1/2 x 9-1/4 - 9-1/2
THF25925 IUS2.56/9.5, IUT310, MIU2.56/9
-- 18 2-1/2 9-1/8 2-1/2 12 10d 2 10d x 1-1/2 1370 1575 1710 175 1175 1350 1470 150
2-1/2 x 11-1/4 - 11-7/8
THF25112 IUS2.56/11.88, IUT312, MIU2.56/11
-- 18 2-1/2 11-1/8 2-1/2 14 10d 2 10d x 1-1/2 1595 1835 1995 360 1370 1580 1715 310
1) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 2) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 3) Minimum nail penetration shall be 1-1/2˝ for 10d nails and 1-5/8˝ for 16d nails. 4) WS3 Wood Screws are 1/4˝ x 3˝ and are included with HDQ hangers. Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.
5,F30,R5
5,F30,R5
5,F30,R5
1-5/8 x 14 -- 18 1-5/8
1-5/8 x 9-1/4 - 9-1/2 -- 18 1-5/8
1-5/8 x 11-1/4 - 12 -- 18 1-5/8
13-1/4 2
2 - 2-1/8 x 11-7/8
--
2 - 2-1/8 x 14 -- 18 2-1/8
18 2-1/8
13-3/8 2
8-7/8 2
11-3/16 2
2 - 2-1/8 x 9-1/2
-- 18 2-1/8
1-3/4 x 14 -- 18 1-3/4
10-15/16 2
1-3/4 x 9-1/4 - 9-1/2
--
1-3/4 x 11-7/8 -- 18 1-3/4
18 1-3/4
13-1/2 2
8-15/16 2
9 2
11 2
13-7/16 2
1-1/2 x 14 -- 18 1-1/2
1-1/2 9-1/16 2
1-1/2 x 11-1/4 - 11-7/8
-- 18 1-1/2 11-1/16 2
USPStock No.
1-1/2 x 9-1/2 -- 18
Web
Stif
fene
r Req
d.
Ste
el G
auge
Fastener Schedule4 Allowable Loads (Lbs.)
Header3
Joist1
DF-L / SP Header S-P-F Header
WD
H
EW
PH
an
gers
1-800-328-5934 • www.USPconnectors.com120
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®EWP Face Mount Hangers – I-Joist Charts continued
WD
H
Dimensions
Uplift2 Uplift2
Code
Joist Size Ref. No. W H D Qty Type Qty Type 100% 115% 125% 160% 100% 115% 125% 160% Ref.
2-1/2 x 13 THF25130 IUT313 -- 16 2-1/2 12-1/4 2-1/2 18 10d 2 10d x 1-1/2 2090 2280 2280 360 1800 1915 1915 310
2-1/2 x 14 THF25140 IUS2.56/14, IUT314, MIU2.56/14
-- 16 2-1/2 13-7/16 2-1/2 18 10d 2 10d x 1-1/2 2090 2400 2610 360 1800 2070 2250 310
2-1/2 x 16 THF25160
IUS2.56/16, IUT316, MIU2.56/16, MIU2.56/18, MIU2.56/20
-- 16 2-1/2 15-1/2 2-1/2 22 10d 2 10d x 1-1/2 2550 2935 3035 360 2200 2530 2550 310
2-1/2 x 18 - 24 THF25160
IUS2.56/16, IUT316, MIU2.56/16, MIU2.56/18, MIU2.56/20
x 16 2-1/2 15-1/2 2-1/2 22 10d 2 10d x 1-1/2 2550 2935 3035 360 2200 2530 2550 310
2-5/8 x 9-1/4 - 9-1/2 THF26925 IUT2.68/10 -- 18 2-5/8 9-1/16 2-1/2 12 10d 2 10d x 1-1/2 1370 1575 1710 175 1175 1350 1470 150
2-5/8 x 11-1/4 - 11-7/8 THF26112 IUT2.68/12 -- 18 2-5/8 11-1/16 2-1/2 14 10d 2 10d x 1-1/2 1595 1835 1995 360 1370 1580 1715 310
2-5/8 x 14 THF26140 -- -- -- 16 2-5/8 13-3/8 2-1/2 18 10d 2 10d x 1-1/2 2090 2400 2610 360 1800 2070 2250 310
2-5/8 x 16 THF26160 -- -- -- 16 2-5/8 15-7/16 2-1/2 22 10d 2 10d x 1-1/2 2550 2935 3035 360 2200 2530 2750 310
3 x 9-1/4 - 14 THF15925-2 MIU3.12/9 x 16 3-1/8 9-3/16 2-1/2 12 10d 6 10d 1390 1600 1740 1115 1200 1380 1500 960
3 x 11-1/4 - 14 THF15112-2 MIU3.12/11 x 16 3-1/8 10-13/16 2-1/2 14 10d 6 10d 1625 1870 2030 1115 1400 1610 1750 960
3 x 14 THF15140-2 -- -- x 12 3-1/8 12-3/4 2-1/2 18 10d 6 10d 2285 2630 2860 1220 1980 2275 2420 1055
3-1/4 x 9-1/4 - 14 THF16925-2 -- -- x 16 3-3/8 9-1/16 2-1/2 12 10d 6 10d 1390 1600 1740 1115 1200 1380 1500 960
3-1/4 x 11-1/4 - 14 THF16112-2 HU3.31/11 x 16 3-3/8 10-3/4 2-1/2 14 10d 6 10d 1625 1870 2030 1115 1400 1610 1750 960
3-1/4 x 14 THF16140-2 -- -- x 12 3-3/8 12-5/8 2-1/2 18 10d 6 10d 2285 2630 2860 1220 1980 2275 2475 1055
3-1/2 x 9-1/4 - 9-1/2
THF35925 IUS3.56/9.5, IUT410
-- 18 3-1/2 8-5/8 2-1/2 12 10d 2 10d x 1-1/2 1370 1575 1710 245 1175 1350 1470 205
3-1/2 x 11-1/4 THF35112 IUS3.56/11.88, IUT412
-- 18 3-1/2 10-5/8 2-1/2 16 10d 2 10d x 1-1/2 1825 2100 2280 245 1570 1805 1960 205
3-1/2 x 14 THF35140 IUS3.56/14, IUT414
-- 16 3-1/2 12-15/16 2-1/2 20 10d 2 10d x 1-1/2 2320 2670 2900 245 2000 2300 2500 205
3-1/2 x 16 - 22 THF17157-2 -- -- x 12 3-5/8 15-3/4 2-1/2 22 10d 6 10d 2795 3215 3495 1220 2420 2785 3025 1055
3-1/2 x 16 THF35157 IUS3.56/16, IUT416
-- 16 3-1/2 15 2-1/2 22 10d 2 10d x 1-1/2 2550 2935 3190 245 2200 2530 2750 205
3-1/2 x 18 - 26 THF35165 -- -- x 16 3-1/2 16-9/16 2-1/2 24 10d 8 10d x 1-1/2 2785 3200 3480 1295 2400 2760 3000 1085
4 - 4-3/16 x 9-1/2 THF20925-2
HU4.12/9, HU4.28/9, HU4.75/9, MIU4.12/9, MIU4.28/9
-- 16 4-3/16 8-11/16 2-1/2 12 10d 6 10d 1390 1600 1740 1115 1200 1380 1500 960
4 - 4-3/16 x 11-7/8
THF20112-2
HU4.12/11, HU4.28/11, HU4.75/11, MIU4.12/11, MIU4.28/11
-- 16 4-3/16 11 2-1/2 16 10d 6 10d 1855 2135 2320 1115 1600 1840 2000 960
4 - 4-3/16 x 14 THF20140-2
MIU4.12/14, MIU4.12/16, MIU4.28/14, MIU4.28/16
-- 16 4-3/16 13-5/8 2-1/2 20 10d 6 10d 2320 2670 2900 1115 2000 2300 2500 960
4-5/8 x 9-1/4 - 14
THF23925-2 -- -- x 16 4-3/4 8-3/8 2-1/2 14 10d 6 10d 1625 1870 2030 1115 1400 1610 1750 960
4-5/8 x 11-1/4 - 16
THF23118-2 -- -- x 16 4-3/4 10-11/16 2-1/2 16 10d 6 10d 1855 2135 2320 1115 1600 1840 2000 960
4-5/8 x 14 - 22 THF23140-2 HU3514-2, MIU4.75/14
x 12 4-3/4 13-5/16 2-1/2 20 10d 6 10d 2540 2920 3175 1220 2200 2530 2750 1055
4-5/8 x 16 - 26 THF23160-2
HU3516-2, HU3520-2, MIU4.75/16, MIU4.75/18, MIU4.75/20
x 12 4-3/4 15-15/16 2-1/2 24 10d 6 10d 3050 3505 3810 1220 2640 3035 3300 1055
5 x 9-1/4 - 11-7/8
THF25925-2 MIU5.12/9 x 16 5-1/8 8-3/16 2-1/2 12 10d 6 10d 1390 1600 1740 1115 1200 1380 1500 960
5 x 11-1/4 - 16 THF25112-2 MIU5.12/11 x 16 5-1/8 10-7/16 2-1/2 16 10d 6 10d 1855 2135 2320 1115 1600 1840 2000 960
5 x 14 - 20 THF25140-2 HU314-2, MIU5.12/14
x 12 5-1/8 13-1/8 2-1/2 20 10d 6 10d 2540 2920 3175 1220 2200 2530 2750 1055
5 x 16 - 26 THF25160-2
HU5.125/16, MIU5.12/16, MIU5.12/18, MIU5.12/20
x 12 5-1/8 15-3/4 2-1/2 24 10d 6 10d 3050 3505 3810 1220 2640 3035 3300 1055
7 x 9-1/4 - 14 HD7100 HU410-2 x 14 7-1/8 9 2-1/2 12 16d 6 10d 1690 1945 2115 1140 1450 1670 1815 990
7 x 11-1/4 - 14 HD7120 HU412-2 x 14 7-1/8 10-5/8 2-1/2 16 16d 6 10d 2255 2595 2820 1140 1935 2225 2420 990
7 x 14 HD7140 HU414-2 x 14 7-1/8 13-1/8 2-1/2 20 16d 8 10d 2820 3245 3525 1525 2420 2785 3025 1320
1) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 2) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 3) Minimum nail penetration shall be 1-1/2˝ for 10d nails and 1-5/8˝ for 16d nails. 4) WS3 Wood Screws are 1/4˝ x 3˝ and are included with HDQ hangers. Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.
USPStock No.
Web
Stif
fene
r Req
d.
Ste
el G
auge
Fastener Schedule4 Allowable Loads (Lbs.)
Header3
Joist1
DF-L / SP Header S-P-F Header
5,F30,R5
5,F30,R5
USP2173-111
EW
PH
an
gers
1-800-328-5934 • www.USPconnectors.com 121
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®EWP Face Mount Hangers – SCL Charts
continued on next page WD
H
Dimensions
Uplift2 Uplift2
Code
Joist Size Ref. No. W H D Qty Type Qty Type 100% 115% 125% 160% 100% 115% 125% 160% Ref.
1-3/4 x 7-1/4 HD1770 HU7 x 14 1-13/16 7-1/8 2 14 16d 4 10d x 1-1/2 1975 2270 2335 730 1695 1945 1960 635
HD17925 HU9, MIU1.81/9
x 14 1-13/16 9-1/8 2 18 16d 6 10d x 1-1/2 2540 2775 2775 1065 2080 2170 2230 895
HDQ179IF HUCQ1.81/9-SDS x 14 1-13/16 9 3 8 WS3 4 WS15 3010 3380 3380 1050 2840 2840 2840 990 110
HUS179 HUS1.81/10 x 16 1-13/16 9-1/8 3 30 16d 10 16d 5310 5510 5510 3205 4410 4630 4630 26906, F15,
F18, D2,R13
HD17112 HU11, MIU1.81/11
x 14 1-13/16 11-3/8 2 22 16d 6 10d x 1-1/2 2870 2975 3045 1065 2080 2170 2230 8955,
F30, R5
HDQ17112IF HUCQ1.81/11-SDS x 14 1-13/16 11 3 10 WS3 6 WS15 3340 3340 3340 1575 2805 2805 2805 1325 110
HUS179 HUS1.81/10 x 16 1-13/16 9-1/8 3 30 16d 10 16d 5310 5510 5510 3205 4410 4630 4630 26906, F15,
F18, D2,R13
HD1714
HU14, MIU1.81/14, MIU1.81/16, MIU1.81/18, U14
x 14 1-13/16 13-5/16 2 26 16d 8 10d x 1-1/2 3100 3235 3330 1065 2280 2400 2480 8955,
F30,R5
HDQ1714IF -- -- x 14 1-13/16 13-3/8 3 12 WS3 6 WS15 3340 3340 3340 1580 2805 2805 2805 1325 110
HUS179 HUS1.81/10 x 16 1-13/16 9-1/8 3 30 16d 10 16d 5310 5510 5510 3205 4410 4630 4630 26906, F15,
F18, D2,R13
HD1714
HU14, MIU1.81/14, MIU1.81/16, MIU1.81/18, U14
x 14 1-13/16 13-5/16 2 26 16d 8 10d x 1-1/2 3100 3235 3330 1065 2280 2400 2480 8955,
F30,R5
HDQ1714IF -- -- x 14 1-13/16 13-3/8 3 12 WS3 6 WS15 3340 3340 3340 1580 2805 2805 2805 1325 110
HUS179 HUS1.81/10 x 16 1-13/16 9-1/8 3 30 16d 10 16d 5310 5510 5510 3205 4410 4630 4630 26906, F15,
F18, D2,R13
HD27925 HU2.75/10 x 14 2-3/4 8-5/8 2 18 16d 6 10d x 1-1/2 2540 2775 2775 1065 2180 2330 2330 895 5, F30, R5
THDH27925 HGUS2.75/10 x 12 2-3/4 9-1/8 4 46 16d 12 16d 8260 8260 8260 3490 6935 6935 6935 29306, F15,
F18, D2,R13
HD27112 HU2.75/12 x 14 2-3/4 10-7/8 2 22 16d 6 10d x 1-1/2 3100 3565 3610 1065 2660 2965 3025 895 5, F30, R5
THDH27112 HGUS2.75/12 x 12 2-3/4 10-7/8 4 56 16d 14 16d 9845 9845 9845 5225 7655 8135 8270 4390 6, F15, R13
HD2714 HU2.75/14 x 14 2-3/4 12-7/8 2 26 16d 8 10d x 1-1/2 3610 3610 3610 1065 3030 3030 3030 895 5, F30, R5
THDH2714 HGUS2.75/14 x 12 2-3/4 12-1/4 4 66 16d 16 16d 9845 9845 9845 6810 8110 8270 8270 5835 6, F15, R13
HD410 HU410, MIU3.56/9
x 14 3-9/16 8-13/16 2-1/2 18 16d 10 10d 2540 2920 3175 1905 2180 2505 2725 1650 5, F30, R5
HDQ410IF HUCQ410-SDS x 14 3-9/16 9 3 12 WS3 6 WS3 4510 5190 5590 2975 4430 4695 4695 2500 110
THD410 HHUS410 x 14 3-5/8 9-1/16 3 38 16d 20 10d 5360 6160 6700 3810 4600 5290 5750 32355, F18,
F30, D2, R5
THDH410 HGUS410 x 12 3-9/16 9-1/8 4 46 16d 12 16d 8260 9010 9010 3970 7120 7570 7570 33356, F18,
F15, D2, R13
HD412 HU412, MIU3.56/11
x 14 3-9/16 10-13/16 2-1/2 22 16d 10 10d 3100 3565 3880 1905 2660 3060 3330 1650 5, F30, R5
HDQ412IF HUCQ412-SDS x 14 3-9/16 11 3 14 WS3 6 WS3 5265 5590 5590 2975 4695 4695 4695 2500 110
THD412 -- -- x 14 3-5/8 11 3 48 16d 20 10d 6770 7045 7045 3810 5810 5920 5920 32355, F18,
F30, D2, R5
THDH412 HGUS412 x 12 3-9/16 10-1/2 4 56 16d 14 16d 9845 9845 9845 5225 8270 8270 8270 4390 6, F15, R13
1) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 2) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 3) Minimum nail penetration shall be 1-1/2˝ for 10d nails and 1-5/8˝ for 16d nails. 4) WS3 Wood Screws are 1/4˝ x 3˝ and are included with HDQ hangers. Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation. New products or updated product information are designated in bold font.
USPStock No. S
teel
Gau
ge
Web
Stif
fene
r Req
d.
Header3
Joist1
Fastener Schedule4 Allowable Loads (Lbs.)
DF-L / SP Header S-P-F Header
1-3/4 x 16
1-3/4 x 14
1-3/4 x 9-1/2
1-3/4 x 11-1/4 - 11-7/8
5,F30,R5
2-11/16 x 11-1/4 - 16
2-11/16 x 14 - 16
3-1/2 x 9-1/4 - 14
3-1/2 x 11-1/4 - 16
2-11/16 x 9-1/4 - 14
EW
PH
an
gers
EWP Face Mount Hangers – SCL Charts continued
1-800-328-5934 • www.USPconnectors.com122
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
Dimensions
Uplift2 Uplift2
Code
Joist Size Ref. No. W H D Qty Type Qty Type 100% 115% 125% 160% 100% 115% 125% 160% Ref.
HD414 HU414, MIU3.56/14
x 14 3-9/16 12-13/16 2-1/2 24 16d 10 10d 3385 3890 4230 1905 2905 3340 3630 1650 5, F30, R5
THD414 -- -- x 14 3-5/8 12-7/8 3 58 16d 20 10d 7045 7045 7045 3810 5920 5920 5920 3235 5, F30, R5
THDH414 HGUS414 x 12 3-9/16 13-1/16 4 66 16d 16 16d 9845 9845 9845 6810 8270 8270 8270 5835 6, F15, R13
3-1/2 x 16 - 22 HD416 HU416, MIU3.56/16
x 14 3-9/16 14-13/16 2-1/2 26 16d 12 10d 3665 4215 4570 2285 3145 3620 3840 1980
3-1/2 x 18 - 26 HD418 MIU3.56/18, MIU3.56/20
x 14 3-9/16 16-1/2 2-1/2 28 16d 8 10d 3950 4540 4570 1425 3390 3840 3840 1195
HD5210 HU5.31/9 x 14 5-3/8 7-7/8 2-1/2 18 16d 10 10d 2540 2920 3175 1905 2180 2505 2725 1650
HDQ5210IF HUCQ5.25/9-SDS x 14 5-1/4 9 3 12 WS3 6 WS3 4510 5190 5590 2975 4430 4695 4695 2500 110
THD610 HHUS5.50/10 x 12 5-1/2 9 3 38 16d 20 10d 5660 6510 7080 3410 4900 5635 6130 28655, F18,
F30, D2, R5
THDH610 HGUS5.25/10, HGUS5.50/10
x 12 5-1/2 9 4 46 16d 16 16d 8725 9855 9855 4565 7520 8275 8275 3835 6, F15, R13
HD5212 HU5.31/11 x 14 5-3/8 9-7/8 2-1/2 22 16d 10 10d 3100 3565 3880 1905 2660 3060 3330 1650 5, F30, R5
HDQ5212IF HUCQ5.25/11-SDS x 14 5-1/4 11 3 14 WS3 6 WS3 5265 5590 5590 2975 4695 4695 4695 2500 110
THD612 -- -- x 12 5-1/2 11 3 48 16d 20 10d 7150 8225 8415 4065 6190 7070 7070 35205, F18,
F30, D2, R5
THDH612 HGUS5.25/12, HGUS5.50/12
x 12 5-1/2 11 4 56 16d 20 16d 9935 9935 9935 5180 8345 8345 8345 4355 6, F15, R13
HD5214 HU5.31/14 x 14 5-3/8 11-7/8 2-1/2 24 16d 10 10d 3385 3890 4230 1905 2905 3340 3630 1650 5, F30, R5
THD614 -- -- x 12 5-1/2 12-7/8 3 58 16d 20 10d 8415 8415 8415 4065 7070 7070 7070 3520 5, F30, R5
THDH614 HGUS5.50/14 x 12 5-1/2 13 4 66 16d 22 16d 11645 11645 11645 5795 9780 9780 9780 4865 6, F15, R13
5-1/4 x 16 - 22 HD5216 HU5.31/16 x 14 5-3/8 13-7/8 2-1/2 30 16d 12 10d 4230 4570 4570 2285 3630 3840 3840 1980 5, F30, R5
6-3/4 x 9 - 14-1/2 THDH6710 HGUS210-4, HGUS6.88/10
x 12 6-7/8 8-13/16 4 46 16d 12 16d 8260 8260 8260 3490 6935 6935 6935 29306, F15,
F18, D2,R13
6-3/4 x 11 - 18 THDH6712 HGUS212-4, HGUS6.88/12
x 12 6-7/8 10-13/16 4 56 16d 14 16d 9845 9845 9845 5225 8270 8270 8270 4390
6-3/4 x 13 - 20-1/2 THDH6714 HGUS214-4, HGUS6.88/14
x 12 6-7/8 12-13/16 4 66 16d 16 16d 9845 9845 9845 6810 8270 8270 8270 5835
HD7100 HU410-2 x 14 7-1/8 9 2-1/2 12 16d 6 10d 1690 1945 2115 1140 1450 1670 1815 990 5, F30, R5
THD7210 HHUS7.25/10 x 12 7-1/4 9 3 38 16d 20 10d 5660 6510 7080 3410 4900 5635 6130 28655, F18,
F30, D2,R5
THDH7210 HGUS7.25/10 x 12 7-1/4 9 4 46 16d 12 16d 8260 9010 9010 3970 7120 7570 7570 33356, F15,
F18, D2,R13
HD7120 HU412-2 x 14 7-1/8 10-5/8 2-1/2 16 16d 6 10d 2255 2595 2820 1140 1935 2225 2420 990 5, F30, R5
THDH7212 HGUS7.25/12 x 12 7-1/4 10-1/2 4 56 16d 14 16d 9845 9845 9845 5225 8270 8270 8270 4390 6, F15, R13
HD7140 HU414-2 x 14 7-1/8 13-1/8 2-1/2 20 16d 8 10d 2820 3245 3525 1525 2420 2785 3025 1320 5, F30,R5
THDH7214 HGUS7.25/14 x 12 7-1/4 12-1/4 4 66 16d 16 16d 9845 9845 9845 6810 8270 8270 8270 5835 6, F15, R13
7 x 16 - 22 HD7160 -- -- x 14 7-1/8 15-5/8 2-1/2 24 16d 8 10d 3385 3890 4230 1525 2905 3340 3630 1320
7 x 18 - 26 HD7180 -- -- x 14 7-1/8 17-3/4 2-1/2 28 16d 8 10d 3950 4540 4570 1525 3390 3840 3840 1320
1) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 2) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 3) Minimum nail penetration shall be 1-1/2˝ for 10d nails and 1-5/8˝ for 16d nails. 4) WS3 Wood Screws are 1/4˝ x 3˝ and are included with HDQ hangers. Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.
USPStock No.
Web
Stif
fene
r Req
d.
Ste
el G
auge
Fastener Schedule4 Allowable Loads (Lbs.)
Header3
Joist1
DF-L / SP Header S-P-F Header
3-1/2 x 14 - 20
5,F30,R5
7 x 9-1/4 - 14
5-1/4 x 14 - 20
6,F15,R13
5, F30,R5
5-1/4 x 9-1/4 - 11-7/8
5-1/4 x 11-1/4 - 16
7 x 11-1/4 - 16
7 x 14 - 20
WD
H
USP2173-111
EW
PH
an
gers
1-800-328-5934 • www.USPconnectors.com 123
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®Top Mount Hangers – BPH, TFI, TFL, & THO series
H
D
1 15/16˝
1 1/2˝
W
TFL
Uplift4 Uplift4
Qty Type Qty Type 100% 160% 100% 160%
2X 6 10d x 1-1/2 2 10d x 1-1/2 1270 360 1090 310
3X 6 16d x 2-1/2 2 10d x 1-1/2 1600 360 1375 310(2) 2X 6 10d 2 10d x 1-1/2 1280 360 1100 310
4X 6 16d 2 10d x 1-1/2 1760 360 1515 310
2X 6 10d x 1-1/2 2 10d x 1-1/2 1360 360 1170 3103X 6 16d x 2-1/2 2 10d x 1-1/2 1470 360 1265 310
(2) 2X 6 10d 2 10d x 1-1/2 1365 360 1175 3104X 6 16d 2 10d x 1-1/2 1535 360 1320 310
2X 6 10d x 1-1/2 6 10d 1455 360 1250 310
3X 6 16d x 2-1/2 6 10d 2335 500 2010 430(2) 2X 10 10d 6 10d 2370 500 2040 430
4X 10 16d 6 10d 2665 500 2290 4304X 6 16d 2 10d x 1-1/2 2560 360 2200 310
4X 10 16d 2 10d x 1-1/2 3245 360 2790 310
2X 6 10d x 1-1/2 4 10d x 1-1/2 2080 230 1790 2003X 8 16d x 2-1/2 4 10d x 1-1/2 2360 535 2030 460
(2) 2X 8 10d 4 10d x 1-1/2 2310 535 1985 4604X 8 16d 4 10d x 1-1/2 2245 535 1930 460
1) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 2) 16d x 2-1/2 nails are 8 gauge (0.162˝ diameter) by 2-1/2˝ long. 3) Listed loads shall not be increased. 4) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted.
THO
BPH
TFL
THO (Double)
TFI
USPSeries
NailerSize
Fastener Schedule1,2 Allowable Loads (Lbs.)3
Header Joist DF-L / SP S-P-F
BPH Specialty Options Chart – refer to SpecialtyOptions pages 194 and 196 for additional details.
Seat Cleat® helps lock I-Joist into place for positive seating and nailing ease.
TFI & THO – Engineered for I-Joist to header applications. Offers full lateral support of theI-Joist top chord, eliminating the need for web stiffeners in most applications. Raised dimple nailing guides help assure correct 45° nailing into the I-Joist bottom flange. TheTHO’s feature the patented Seat Cleat® that allows for quick, positive seating. The SeatCleat® will hold the I-Joist in place, eliminating spring back during nailing in the bottomflange.
TFL – Features 11/2˝ top flange depth that accommodates all header types as well asback-to-back installations. Also features USP’s patented Seat Cleat® for quick, positiveseating.
BPH – These hangers are used to support LVL, LSL, and PSL beams and headers in light-to-medium load conditions.
Materials: See EWP Top Mount Hangers charts, pages 127-134.Finish: G90 galvanizingCodes: ESR-1178, ESR-1831, ESR-1280, ESR-1781,
FL815, FL822, FL11664, FL1190, FL13285,L.A. City RR 25749, L.A. City RR 25836, L.A. City RR 25843
Patents: #5,564,248 – THO & TFL
Installation:• Use all specified fasteners. See Product Notes, page 11.• Refer to the top mount chart for applications requiring web stiffeners.• Requirements for web stiffener from the I-Joist manufacturer should be followed, even if web stiffeners are not required in USP literature.• For BPH welded installation, see page 198. • Uplift capacity for THO and TFL single ply hangers installed without joist nails = 85 lbs. Refer to THO, TFL, & THF Single Ply I-Joist Hangers Technical Bulletin – USP1040.
H
D
TF
W
TFI
THO
H
TF
DW
BPH Typical BPHinstallation
Typical TFLinstallation
Typical THOinstallation
Nailer Options – chart represents maximum allowable loadsfor hangers used on wood nailers. Reference page 115.
Option Skewed1,3 Sloped Seat2,3 Sloped / Skewed1,2,3 Sloped Top Flange4
Range 1˚ to 50˚ 1˚ to 45˚ See Sloped Seat and Skewed 0˚ to 45˚
1) Skewed hangers with skews greater than 15° may have all joist nailing on outside flange. 2) Sloped or sloped / skewed hangers with slopes greater than 15° may have additional joist nails. 3) All sloped, skewed or combinations require bevel cut on joist in all applications and web stiffeners with I-joists. 4) Sloped top flanges with slopes greater than 15° may have additional header nails.
100% of table loadReduce allowabletable loads using
straight-line interpolation
Add SK,angle required,and right (R)or left (L),
to product number.Ex. BPH3595-SK45R
Add SL,slope required,and up (U) or down (D),
to product number.Ex. BPH3595-SL30D
See Sloped Seat and Skewed.Ex. BPH3595-SK45RSL30D
Add SF,angle requiredand right (R) or left (L),
to product number.Ex. BPH3595-SF30L
AllowableLoads
Ordering
100% of table load 100% of table load
Slant Nailingvia dimplenail holes
Diamondholes
Dimensions
Uplift2 Uplift2
Code
Joist Size Ref. No. W H D Qty Type Qty Type 100% 115% 125% 160% 100% 115% 125% 160% Ref.
HD414 x 14 3-9/16 12-13/16 2-1/2 24 16d 10 10d 3385 3890 4230 1905 2905 3340 3630 1650 5, F30, R5
THD414 -- -- x 14 3-5/8 12-7/8 3 58 16d 20 10d 7045 7045 7045 3810 5920 5920 5920 3235 5, F30, R5
THDH414 HGUS414 x 12 3-9/16 13-1/16 4 66 16d 16 16d 9845 9845 9845 6810 8270 8270 8270 5835 6, F15, R13
3-1/2 x 16 - 22 HD416 x 14 3-9/16 14-13/16 2-1/2 26 16d 12 10d 3665 4215 4570 2285 3145 3620 3840 1980
3-1/2 x 18 - 26 HD418 x 14 3-9/16 16-1/2 2-1/2 28 16d 8 10d 3950 4540 4570 1425 3390 3840 3840 1195
HD5210 HU5.31/9 x 14 5-3/8 7-7/8 2-1/2 18 16d 10 10d 2540 2920 3175 1905 2180 2505 2725 1650
HDQ5210IF HUCQ5.25/9-SDS x 14 5-1/4 9 3 12 WS3 6 WS3 4510 5190 5590 2975 4430 4695 4695 2500 110
THD610 HHUS5.50/10 x 12 5-1/2 9 3 38 16d 20 10d 5660 6510 7080 3410 4900 5635 6130 2865
THDH610 x 12 5-1/2 9 4 46 16d 16 16d 8725 9855 9855 4565 7520 8275 8275 3835 6, F15, R13
HD5212 HU5.31/11 x 14 5-3/8 9-7/8 2-1/2 22 16d 10 10d 3100 3565 3880 1905 2660 3060 3330 1650 5, F30, R5
HDQ5212IF HUCQ5.25/11-SDS x 14 5-1/4 11 3 14 WS3 6 WS3 5265 5590 5590 2975 4695 4695 4695 2500 110
THD612 -- -- x 12 5-1/2 11 3 48 16d 20 10d 7150 8225 8415 4065 6190 7070 7070 3520
THDH612 x 12 5-1/2 11 4 56 16d 20 16d 9935 9935 9935 5180 8345 8345 8345 4355 6, F15, R13
HD5214 HU5.31/14 x 14 5-3/8 11-7/8 2-1/2 24 16d 10 10d 3385 3890 4230 1905 2905 3340 3630 1650 5, F30, R5
THD614 -- -- x 12 5-1/2 12-7/8 3 58 16d 20 10d 8415 8415 8415 4065 7070 7070 7070 3520 5, F30, R5
THDH614 HGUS5.50/14 x 12 5-1/2 13 4 66 16d 22 16d 11645 11645 11645 5795 9780 9780 9780 4865 6, F15, R13
5-1/4 x 16 - 22 HD5216 HU5.31/16 x 14 5-3/8 13-7/8 2-1/2 30 16d 12 10d 4230 4570 4570 2285 3630 3840 3840 1980 5, F30, R5
6-3/4 x 9 - 14-1/2 THDH6710 x 12 6-7/8 8-13/16 4 46 16d 12 16d 8260 8260 8260 3490 6935 6935 6935 2930
6-3/4 x 11 - 18 THDH6712 x 12 6-7/8 10-13/16 4 56 16d 14 16d 9845 9845 9845 5225 8270 8270 8270 4390
6-3/4 x 13 - 20-1/2 THDH6714 x 12 6-7/8 12-13/16 4 66 16d 16 16d 9845 9845 9845 6810 8270 8270 8270 5835
HD7100 HU410-2 x 14 7-1/8 9 2-1/2 12 16d 6 10d 1690 1945 2115 1140 1450 1670 1815 990 5, F30, R5
THD7210 HHUS7.25/10 x 12 7-1/4 9 3 38 16d 20 10d 5660 6510 7080 3410 4900 5635 6130 2865
THDH7210 HGUS7.25/10 x 12 7-1/4 9 4 46 16d 12 16d 8260 9010 9010 3970 7120 7570 7570 3335
HD7120 HU412-2 x 14 7-1/8 10-5/8 2-1/2 16 16d 6 10d 2255 2595 2820 1140 1935 2225 2420 990 5, F30, R5
THDH7212 HGUS7.25/12 x 12 7-1/4 10-1/2 4 56 16d 14 16d 9845 9845 9845 5225 8270 8270 8270 4390 6, F15, R13
HD7140 HU414-2 x 14 7-1/8 13-1/8 2-1/2 20 16d 8 10d 2820 3245 3525 1525 2420 2785 3025 1320 5, F30,R5
THDH7214 HGUS7.25/14 x 12 7-1/4 12-1/4 4 66 16d 16 16d 9845 9845 9845 6810 8270 8270 8270 5835 6, F15, R13
7 x 16 - 22 HD7160 -- -- x 14 7-1/8 15-5/8 2-1/2 24 16d 8 10d 3385 3890 4230 1525 2905 3340 3630 1320
7 x 18 - 26 HD7180 -- -- x 14 7-1/8 17-3/4 2-1/2 28 16d 8 10d 3950 4540 4570 1525 3390 3840 3840 1320
1) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 2) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 3) Minimum nail penetration shall be 1-1/2˝ for 10d nails and 1-5/8˝ for 16d nails. 4) WS3 Wood Screws are 1/4˝ x 3˝ and are included with HDQ hangers. Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.
Web
Stif
fene
r Req
d.
Ste
el G
auge
EW
PH
an
gers
1-800-328-5934 • www.USPconnectors.com124
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®Beam Hangers – HLBH series
Typical HLBHinstallation
Specialty Options Chart – refer to Specialty Options pages 194, 196 to 197 for additional details.Option Skewed 1,3 Sloped Seat2,3 Sloped / Skewed1,2,3 Sloped Top Flange4 Top Flange Offset Saddle5 Ridge
Range 1˚ to 50˚ 1˚ to 45˚ See Sloped Seat and Skewed 0˚ to 45˚ -- -- -- -- 0˚ to 45˚
1) Skewed hangers with skews greater than 15° may have all joist nailing on outside flange. 2) Sloped or sloped / skewed hangers with slopes greater than 15° may have additional joist nails. 3) All sloped, skewed or combinations require bevel cut on joist in all applications and web stiffeners with I-joists. 4) Sloped top flanges with slopes greater than 15° may have additional header nails. 5) Minimum header thickness shall be double the top flange (TF) dimension for 100% table load.
Add SF,angle required,and right (R)or left (L),
to product number.Ex. HLBH3595-SF30L
Add OS,andright (R)or left (L),to product number.
Ex. HLBH3595-OSL
Reduce allowabletable loads using
straight-lineinterpolation
45% of table load
Ordering
Add SK,angle required,and right (R)or left (L),
to product number.Ex. HLBH3595-SK45R
AllowableLoads
8070 lbs. Max.50% of uplift load on
skew greater than 15˚.7000 lbs. Max.
6650 lbs. Max.50% of uplift load on
skew greater than 15˚.
Add SL,slope required,and up (U)or down (D),
to product number.Ex. HLBH3595-SL30D
See Sloped Seat andSkewed.
Ex. HLBH3595-SK45RSL30D
100% of table loadper side.
See footnote 5.100% of table load
Add SA, and saddlewidth required
to product number.Ex. HLBH3595-SA=5-1/2˝
Add DA,andangle required
to product number.Ex. HLBH3595-DA30
TF4 3/8˝
L
H
DW
HLBH
HLBH – Heavy-duty hanger for LVL, LSL, and PSL beams.
Materials: See EWP Top Mount Hangers charts,pages 129-139.
Finish: USP primerCodes: ESR-1831, FL822, L.A. City RR 25836
Installation:• Use all specified fasteners. See Product Notes, page 11.• For welded installations, see page 198.• 16d ring shank nails are supplied with HLBH hangers.
Fastener Schedule1,2
Uplift Uplift
Qty Type Qty Type 100% 160% 100% 160%
4X 15 NA16D-RS 6 10d x 1-1/2 9600 1390 8255 1195
4X 15 NA16D-RS 6 16d 9600 1605 8255 1380
1) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 2) NA16D-RS nails are 9 gauge (0.148˝ diameter) by 3-1/2˝ long. 3) Listed loads shall not be increased.
S-P-F
Allowable Loads (Lbs.) 3
Header Joist
HLBH
USPSeries
NailerSize
DF-L / SP
HLBH Nailer Options – chart represents maximum allowableloads for hangers used on wood nailers. Reference page 115.
USP2173-111
EW
PH
an
gers
1-800-328-5934 • www.USPconnectors.com 125
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®Top Flange Hangers – MPH, PHM, & PHXU series
MPH – Designed to work with standard 6˝ or larger grouted concrete block wallconstruction. Eliminates the need for masons to fabricate special seats tosupport I-Joists or composite wood beams.
PHM & PHXU – Used to connect LVL, LSL, and PSL beams to headers in medium loadconditions using standard nails.
Materials: See EWP Top Mount Hangers charts, pages 127-134.Finish: USP primer; PHXU – G90 galvanizing.Codes: ESR-1781, ESR-1831, ESR-2104,
FL816, FL820, FL822, FL13285L.A. City RR 25745, L.A. City RR 25836, L.A. City RR 25843
Patents: #6,463,711 B1 – PHXU
Installation:• Use all specified fasteners. See Product Notes, page 11.• For MPH series: 16d duplex nails are not provided. Place hanger on top of concreteblock. Install (2) 16d duplex nails (8 gauge or 0.162˝ dia. x 31⁄2˝ double head) in thegrouted cavity, and then continue laying the next course of block. Larger holes on topflange are provided to aid grout flow. A minimum of one course must be laid over hanger top flange and one course below hanger top flange. Courses adjacent to the topflange shall be subsequently grouted.• For PHM & PHXU welded installations, see page 198.
H
W
3 3/4˝
2 1/2˝
L
MPH
Typical MPHinstallation
H
L
TF
W D
PHXU
Typical PHXUinstallation
continued on next pagecontinued on next page
Install with (2)16d duplex nailsin grouted cells
EW
PH
an
gers
1-800-328-5934 • www.USPconnectors.com126
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®Top Flange Hangers – MPH, PHM, & PHXU series cont.
H
L
TF
WD
Specialty Options Chart – refer to Specialty Options pages 194, 196 to 197 for additional details.Option USP Series Skewed1,3,5 Sloped Seat2,3 Sloped / Skewed 1,2,3 Sloped Top Flange4 Top Flange Offset5 Saddle5,6 Ridge
PHM 1˚ to 84˚ 0˚ to 45˚
PHXU N/A
MPH -- -- N/A N/A
5-9/16˝ to 7-1/2˝ 85%
PHM
Add DA,andangle required to
to product number.Ex. PHXU17955-DA30
PHXU N/A
MPH N/A N/A
1) Skewed hangers with skews greater than 15° may have all joist nailing on outside flange. 2) Sloped or sloped/skewed hangers with slopes greater than 15° may have additional joist nails. 3) All sloped, skewed, or combinations require bevel cut on joist in all applications and web stiffeners with I-joists. 4) Sloped top flanges with slopes greater than 15° may have additional header nails. 5) Skewed, top flange offset, or saddle options will have a solid, welded top flange. 6) Minimum header thickness shall be double the top flange (TF) dimension for 100% table load.
Range
AllowableLoads
Add SK,angle required, andright (R)or left (L),to product number.
Ex. PHXU1795-SK45R
Ordering
PHXU
PHM
MPH
100% of table load.See footnote 6.
Add OS,andright (R)or left (L),
to product number.Ex. PHXU1795-OSL
100% of table load100% of table load
100% of table load.
Add SL,slope required, andup (U)or down (D),to product number.
Ex. PHXU1795-SL30D
See Sloped Seatand Skewed.
Ex.PHXU1795-SK45RSL30D
Add SF,angle required, andright (R)or left (L),to product number.
Ex. PHXU1795-SF30L
1˚ to 60˚1˚ to 45˚
Add SA,and saddle
width requiredto product number.
Ex. PHXU1795-SA=5-1/2˝
100% of table load
Reduceallowable table
loads usingstraight-lineinterpolation
100% of table load up toMax. load of 3900 lbs.
100% of table load up toMax. load of 2500 lbs.
See Sloped Seatand Skewed
-- --0° to 35° -- --
Fastener Schedule1,2
Uplift Uplift
Qty Type Qty Type 100% 160% 100% 160%
2X 2 10d x 1-1/2 2 10d x 1-1/2 3010 -- -- 2590 -- --
3X 2 16d x 2-1/2 2 10d x 1-1/2 3570 -- -- 3070 -- --(2) 2X 2 10d 2 10d x 1-1/2 3325 -- -- 2860 -- --
4X 2 16d 2 10d x 1-1/2 3255 -- -- 2800 -- --
PHXU 1-3/4˝ widths
4X 8 16d 6 10d x 1-1/2 4425 1035 3805 890
4X 8 16d 6 10d x 1-1/2 5285 970 4545 835
4X 8 16d 6 10d 5285 1290 4545 1110
1) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 2) 16d x 2-1/2 nails are 89 gauge (0.1628˝ diameter) by 2-1/2˝ long. 3) Listed loads shall not be increased.
Allowable Loads (Lbs.)3
S-P-FHeader Joist
USPSeries
NailerSize
PHXU 2-3/4˝ > widths
DF-L / SP
PHM
PHM & PHXU Nailer Options – chart represents maximum allowable loads for hangers used on woodnailers. Reference page 115.
PHM
USP2173-111
EW
PH
an
gers
1-800-328-5934 • www.USPconnectors.com 127
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
Dimensions Fastener Schedule2,3,4,8 100% Allowable Loads (Lbs.)1,5,7 DF-L/SP
Uplift6
Joist SizeUSP
Stock No.
Ref. No.
Ste
el G
auge
W H D L TF Qty Type Qty Type DF-
L / S
P I-
Jois
t9
LVL
PSL
LSL
DF-
L / S
P
SPF
Mas
onry
160
% CodeRef.
THO15925 ITT29.25 -- 18 1-9/16 9-1/4 2 -- 1-1/2 6 10d 2 10d x 1-1/2 1005 1345 1290 1335 1005 845 -- 230 5, F30, R5
BPH15925 LBV1.56/9.25 x 12 1-9/16 9-1/4 2-3/8 -- 1-1/2 10 16d 4 10d x 1-1/2 -- 3120 3065 3065 2705 1990 -- 625 10, F16, R14
MPH210 WM210, WM29.25
-- 12 1-9/16 9-1/4 2-1/2 7 3-3/4 2 16d duplex 2 10d x 1-1/2 -- -- -- -- -- -- 2585 -- 5, F30, R5
THO15950 ITT29.5 -- 18 1-1/2 9-1/2 2 -- 1-1/2 6 10d 2 10d x 1-1/2 1090 1345 1290 1335 1090 915 -- 270 5, F30, R5
BPH1595 LBV1.56/9.5, MIT29.5
x 12 1-9/16 9-1/2 2-3/8 -- 1-1/2 10 16d 4 10d x 1-1/2 -- 3120 3065 3065 2705 1990 -- 625 10, F16, R14
MPH1595 WM29.5 -- 12 1-9/16 9-1/2 2-1/2 7 3-3/4 2 16d duplex 2 10d x 1-1/2 -- -- -- -- -- -- 2585 -- 5, F30, R5
BPH15112 LBV1.56/11.25 x 12 1-9/16 11-1/4 2-3/8 -- 1-1/2 10 16d 4 10d x 1-1/2 -- 3120 3065 3065 2705 1990 -- 625 10, F16, R14
MPH212 WM211.25, WM212
-- 12 1-9/16 11-1/4 2-1/2 7 3-3/4 2 16d duplex 2 10d x 1-1/2 -- -- -- -- -- -- 2585 -- 5, F30, R5
THO15118 ITT211.88, MIT211.88
-- 18 1-1/2 11-7/8 2 -- 1-9/16 6 10d 2 10d x 1-1/2 1205 1345 1290 1335 1205 1015 -- 270 5, F30, R5
BPH15118 LBV1.56/11.88 x 12 1-9/16 11-7/8 2-3/8 -- 1-1/2 10 16d 4 10d x 1-1/2 -- 3120 3065 3065 2705 1990 -- 625 10, F16, R14
MPH15118 WM211.88 -- 12 1-9/16 11-7/8 2-1/2 7 3-3/4 2 16d duplex 2 10d x 1-1/2 -- -- -- -- -- -- 2585 -- 5, F30, R5
THO15140 ITT214 -- 16 1-9/16 14 2-3/8 -- 1-1/2 10 10d 2 10d x 1-1/2 1030 1030 1030 1030 1030 865 -- 230 5, F30, R5 BPH1514 LBV1.56/14 x 12 1-9/16 14 2-3/8 -- 1-1/2 10 16d 4 10d x 1-1/2 -- 3120 3065 3065 2705 1990 -- 625 10, F16, R14
MPH1514 -- -- -- 12 1-9/16 14 2-1/2 7 3-3/4 2 16d duplex 2 10d x 1-1/2 -- -- -- -- -- -- 2585 -- 5, F30, R5
1-5/8 x 9-1/2 THO16950 -- -- -- 18 1-11/16 9-1/2 2 -- 1-1/2 6 10d 2 10d x 1-1/2 1005 1345 1290 1335 1005 845 -- 230 5, F30, R5
1-5/8 x 11-1/4 THO16112 -- -- -- 16 1-11/16 11-1/4 2 -- 1-1/2 6 10d 2 10d x 1-1/2 1030 1345 1290 1335 1030 865 -- 230 5, F30, R5
1-5/8 x 11-7/8 THO16118 -- -- -- 16 1-11/16 11-7/8 2 -- 1-1/2 6 10d 2 10d x 1-1/2 1030 1345 1290 1335 1030 865 -- 230 5, F30, R5 1-5/8 x 14 THO16140 -- -- -- 16 1-11/16 14 3 -- 1-3/4 10 10d 2 10d x 1-1/2 1030 1030 1030 1030 1030 865 -- 230 5, F30, R5
1-3/4 x 7-1/4 PHXU17725 LBV1.81/7.25, WP1.81/7.25
x 7 1-13/16 7-1/4 3-1/4 10 2-1/2 8 16d 6 10d x 1-1/2 -- 4420 4425 4425 4425 3070 -- 1035 8, R9
BPH17925 ITT9.25, LBV1.81/9.25
x 12 1-13/16 9-1/4 2-3/8 -- 1-11/16 10 16d 4 10d x 1-1/2 -- 3340 3395 3395 3030 2245 -- 625
PHM17925 WP9.25 x 7/10 1-13/16 9-1/4 2-1/2 7 3 2 16d 2 10d x 1-1/2 -- 3535 3330 3080 2865 2865 -- --
PHXU17925 WPU1.81/9.25 x 7 1-13/16 9-1/4 3-1/4 10 2-1/2 8 16d 6 10d x 1-1/2 -- 4420 4425 4425 4425 3070 -- 1035 8, F14, R9
THO17950 ITS1.81/9.5, ITT9.5
-- 18 1-3/4 9-1/2 2 -- 1-1/2 6 10d 2 10d x 1-1/2 1260 1345 1290 1335 1260 1060 -- 270 5, F30, R5
BPH1795 LBV1.81/9.5, MIT9.5
x 12 1-13/16 9-1/2 2-3/8 -- 1-11/16 10 16d 4 10d x 1-1/2 -- 3340 3395 3395 3030 2245 -- 625
PHM1795 WP9 x 7/10 1-13/16 9-1/2 2-1/2 7 3 2 16d 2 10d x 1-1/2 -- 3535 3330 3080 2865 2865 -- --
PHXU1795 -- -- x 7 1-13/16 9-1/2 3-1/4 10 2-1/2 8 16d 6 10d x 1-1/2 -- 4420 4425 4425 4425 3070 -- 1035 8, F14, R9
MPH1795 WM9 -- 12 1-13/16 9-1/2 2-1/2 7 3-3/4 2 16d duplex 2 10d x 1-1/2 -- -- -- -- -- -- 2975 -- 5, F30, R5 BPH17112 LBV1.81/11.25 x 12 1-13/16 11-1/4 2-3/8 -- 1-11/16 10 16d 4 10d x 1-1/2 -- 3340 3395 3395 3030 2245 -- 625
PHM17112 -- -- x 7/10 1-13/16 11-1/4 2-1/2 7 3 2 16d 2 10d x 1-1/2 -- 3535 3330 3080 2865 2865 -- --
PHXU17112 WPU1.81/11.25 x 7 1-13/16 11-1/4 3-1/4 10 2-1/2 8 16d 6 10d x 1-1/2 -- 4420 4425 4425 4425 3070 -- 1035 8, F14, R9
THO17118 ITS1.81/11.88, ITT11.88, MIT11.88
-- 18 1-3/4 11-7/8 2 -- 1-9/16 6 10d 2 10d x 1-1/2 1305 1345 1290 1335 1305 1095 -- 270 5, F30, R5
BPH17118 BA1.81/11.88, LBV1.81/11.88
x 12 1-13/16 11-7/8 2-3/8 -- 1-11/16 10 16d 4 10d x 1-1/2 -- 3340 3395 3395 3030 2245 -- 625
PHM17118 WP11 x 7/10 1-13/16 11-7/8 2-1/2 7 3 2 16d 2 10d x 1-1/2 -- 3535 3330 3080 2865 2865 -- --
PHXU17118 WPU1.81/11.88 x 7 1-13/16 11-7/8 3-1/4 10 2-1/2 8 16d 6 10d x 1-1/2 -- 4420 4425 4425 4425 3070 -- 1035 8, F14, R9
MPH17118 WM11 -- 12 1-13/16 11-7/8 2-1/2 7 3-3/4 2 16d duplex 2 10d x 1-1/2 -- -- -- -- -- -- 2975 -- 5, F30, R5
TFL1714 ITS1.81/14, ITT14
-- 18 1-13/16 14 2 -- 1-1/2 6 10d 2 10d x 1-1/2 1245 1645 1600 1700 1600 1230 -- 360 1, F27
BPH1714 LBV1.81/14, MIT1.81/14
x 12 1-13/16 14 2-3/8 -- 1-11/16 10 16d 4 10d x 1-1/2 -- 3340 3395 3395 3030 2245 -- 625 10, R14
PHM1714 WP14 x 7/10 1-13/16 14 2-1/2 7 3 2 16d 2 10d x 1-1/2 -- 3535 3330 3080 2865 2865 -- -- 10, F16, R14 PHXU1714 WPU1.81/14 x 7 1-13/16 14 3-1/4 10 2-1/2 8 16d 6 10d x 1-1/2 -- 4420 4425 4425 4425 3070 -- 1035 8, F14, R9
MPH1714 WM14 -- 12 1-13/16 14 2-1/2 7 3-3/4 2 16d duplex 2 10d x 1-1/2 -- -- -- -- -- -- 2975 -- 5, F30, R5
TFL1716 ITS1.81/16, ITT16
-- 18 1-13/16 16 2 -- 1-1/2 6 10d 2 10d x 1-1/2 1245 1645 1600 1700 1600 1230 -- 360 1, F27
BPH1716 B1.81/16, LBV1.81/16, MIT1.81/16
x 12 1-13/16 16 2-3/8 -- 1-11/16 10 16d 4 10d x 1-1/2 -- 3340 3395 3395 3030 2245 -- 625
PHM1716 WP16 x 7/10 1-13/16 16 2-1/2 7 3 2 16d 2 10d x 1-1/2 -- 3535 3330 3080 2865 2865 -- --
MPH1716 WM16 -- 12 1-13/16 16 2-1/2 7 3-3/4 2 16d duplex 2 10d x 1-1/2 -- -- -- -- -- -- 2975 -- 5, F30, R5
2 - 2-1/8 x 9-1/2 TFL2095 ITS2.06/9.5, ITT2.06/9.5, ITT2.1/9.5
-- 18 2-1/8 9-1/2 2 -- 1-1/2 6 10d 2 10d x 1-1/2 1245 1645 1600 1700 1600 1230 -- 360 1, F27
2 - 2-1/8 x 11-7/8
TFL20118 ITS2.06/11.88, ITT2.06/11.88, ITT2.1/11.88
-- 18 2-1/8 11-7/8 2 -- 1-1/2 6 10d 2 10d x 1-1/2 1245 1645 1600 1700 1600 1230 -- 360 1, F27
See footnotes on page 128.
1-3/4 x 14
1-3/4 x 1610, F16, R14
1-3/4 x 11-1/410, F16, R14
1-3/4 x 11-7/810, F16, R14
1-1/2 x 14
1-3/4 x 9-1/410, F16, R14
1-3/4 x 9-1/2 10, F16, R14
1-1/2 x 9-1/4
1-1/2 x 9-1/2
1-1/2 x 11-1/4
1-1/2 x 11-7/8
Web
Stif
fene
r Req
d.
Header Joist Header Material
EWP Top Mount Hanger Charts
Option USP Series Skewed1,3,5 Sloped Seat2,3 Sloped / Skewed 1,2,3 Sloped Top Flange4 Top Flange Offset5 Saddle5,6 Ridge
PHM 1˚ to 84˚ 0˚ to 45˚
PHXU N/A
MPH -- -- N/A N/A
5-9/16˝ to 7-1/2˝ 85%
PHM
PHXU N/A
MPH N/A N/A
1) Skewed hangers with skews greater than 15° may have all joist nailing on outside flange. 2) Sloped or sloped/skewed hangers with slopes greater than 15° may have additional joist nails. 3) All sloped, skewed, or combinations require bevel cut on joist in all applications and web stiffeners with I-joists. 4) Sloped top flanges with slopes greater than 15° may have additional header nails. 5) Skewed, top flange offset, or saddle options will have a solid, welded top flange. 6) Minimum header thickness shall be double the top flange (TF) dimension for 100% table load.
Dimensions Fastener Schedule2,3,4,8 100% Allowable Loads (Lbs.)1,5,7 DF-L/SP
Uplift6
Joist SizeUSP
Stock No.
Ref. No.
Ste
el G
auge
W H D L TF Qty Type Qty Type DF-
L / S
P I-
Jois
t9
LVL
PSL
LSL
DF-
L / S
P
SPF
Mas
onry
160
% CodeRef.
2 - 2-1/8 x 14 TFL2014 ITS2.06/14, ITT2.06/14, ITT2.1/14
-- 18 2-1/8 14 2 -- 1-1/2 6 10d 2 10d x 1-1/2 1245 1645 1600 1700 1600 1230 -- 360 1, F27
2 - 2-1/8 x 16 TFL2016 ITT2.06/16, ITT2.1/16
-- 18 2-1/8 16 2 -- 1-1/2 6 10d 2 10d x 1-1/2 1245 1645 1600 1700 1600 1230 -- 360 1, F27
TFL2395 ITS2.37/9.5, ITT359.5
-- 18 2-3/8 9-1/2 2 -- 1-1/2 6 10d 2 10d x 1-1/2 1245 1645 1600 1700 1600 1230 -- 360 1, F27
MPH2395 -- -- -- 12 2-3/8 9-1/2 2-1/2 7 3-3/4 2 16d duplex 2 10d x 1-1/2 -- -- -- -- -- -- 3855 -- 5, F30, R5
TFL23118 ITS2.37/11.88, ITT3511.88
-- 18 2-3/8 11-7/8 2 -- 1-1/2 6 10d 2 10d x 1-1/2 1245 1645 1600 1700 1600 1230 -- 360 1, F27
MPH23118 WM3511.88 -- 12 2-3/8 11-7/8 2-1/2 7 3-3/4 2 16d duplex 2 10d x 1-1/2 -- -- -- -- -- -- 3855 -- 5, F30, R5
TFL2314 ITS2.37/14, ITT3514
-- 18 2-3/8 14 2 -- 1-1/2 6 10d 2 10d x 1-1/2 1245 1645 1600 1700 1600 1230 -- 360 1, F27
THO23140 LBV2.37/14, MIT3514
-- 18 2-3/8 14 2-3/8 -- 2 12 10d 2 10d x 1-1/2 2715 2715 2715 2715 2715 2280 -- 265 5, F30, R5
PHM2314 WP3514 x 7/10 2-3/8 14 2-1/2 7 3 2 16d 2 10d x 1-1/2 -- 3570 3570 3080 2865 2865 -- -- 10, F16, R14
MPH2314 -- -- -- 12 2-3/8 14 2-1/2 7 3-3/4 2 16d duplex 2 10d x 1-1/2 -- -- -- -- -- -- 3855 -- 5, F30, R5
TFL2316 -- -- -- 18 2-3/8 16 2 -- 1-1/2 6 10d 2 10d x 1-1/2 1245 1645 1600 1700 1600 1230 -- 360 1, F27
TFI3516 MIT3516 -- 16 2-3/8 16 2-1/2 -- 2-1/16 6 16d 2 10d x 1-1/2 -- 2560 2235 2265 2560 1660 -- 360 2, F20, R12
PHM2316 WP3516 x 7/10 2-3/8 16 2-1/2 7 3 2 16d 2 10d x 1-1/2 -- 3570 3570 3080 2865 2865 -- -- 10, F16, R14
MPH2316 -- -- -- 12 2-3/8 16 2-1/2 7 3-3/4 2 16d duplex 2 10d x 1-1/2 -- -- -- -- -- -- 3855 -- 5, F30, R5
TFI3518 HIT3518, LBV2.37/18, MIT3518
-- 16 2-3/8 18 2-1/2 -- 2-1/16 6 16d 2 10d x 1-1/2 -- 2560 2235 2265 2560 1660 -- 360 2, F20, R12
PHM2318 WP3518 x 7/10 2-3/8 18 2-1/2 7 3 2 16d 2 10d x 1-1/2 -- 3570 3570 3080 2865 2865 -- -- 10, F16, R14 MPH2318 -- -- x 12 2-3/8 18 2-1/2 7 3-3/4 2 16d duplex 2 10d x 1-1/2 -- -- -- -- -- -- 3855 -- 5, F30, R5
TFI3520 HIT3520, LBV2.37/20, MIT3520
-- 16 2-3/8 20 2-1/2 -- 2-1/16 6 16d 2 10d x 1-1/2 -- 2560 2235 2265 2560 1660 -- 360 2, F20, R12
PHM2320 WP3520 x 7/10 2-3/8 20 2-1/2 7 3 2 16d 2 10d x 1-1/2 -- 3570 3570 3080 2865 2865 -- -- 10, F16, R14 MPH2320 -- -- x 12 2-3/8 20 2-1/2 7 3-3/4 2 16d duplex 2 10d x 1-1/2 -- -- -- -- -- -- 3855 -- 5, F30, R5 TFL25925 ITT39.25 -- 18 2-9/16 9-1/4 2 -- 1-1/2 6 10d 2 10d x 1-1/2 1245 1645 1600 1700 1600 1230 -- 360 1, F27 MPH25925 -- -- -- 12 2-1/2 9-1/4 2-1/2 7 3-3/4 2 16d duplex 2 10d x 1-1/2 -- -- -- -- -- -- 4145 -- 5, F30, R5
2-1/2 x 9-3/8 TFL25938 ITT39.37 -- 18 2-9/16 9-3/8 2 -- 1-1/2 6 10d 2 10d x 1-1/2 1245 1645 1600 1700 1600 1230 -- 360 1, F27
TFL2595 ITS2.56/9.5, ITT39.5
-- 18 2-9/16 9-1/2 2 -- 1-1/2 6 10d 2 10d x 1-1/2 1245 1645 1600 1700 1600 1230 -- 360 1, F27
MPH2595 -- -- -- 12 2-1/2 9-1/2 2-1/2 7 3-3/4 2 16d duplex 2 10d x 1-1/2 -- -- -- -- -- -- 4145 -- 5, F30, R5 TFL25112 ITT311.25 -- 18 2-9/16 11-1/4 2 -- 1-1/2 6 10d 2 10d x 1-1/2 1245 1645 1600 1700 1600 1230 -- 360 1, F27 MPH25112 -- -- -- 12 2-1/2 11-1/4 2-1/2 7 3-3/4 2 16d duplex 2 10d x 1-1/2 -- -- -- -- -- -- 4145 -- 5, F30, R5
TFL25118 ITS2.56/11.88, ITT311.88
-- 18 2-9/16 11-7/8 2 -- 1-1/2 6 10d 2 10d x 1-1/2 1245 1645 1600 1700 1600 1230 -- 360 1, F27
THO25118 MIT311.88 -- 16 2-9/16 11-7/8 2-3/8 -- 1-15/16 10 10d 2 10d x 1-1/2 1835 1835 1835 1835 1835 1540 -- 265 5, F30, R5 MPH25118 -- -- -- 12 2-1/2 11-7/8 2-1/2 7 3-3/4 2 16d duplex 2 10d x 1-1/2 -- -- -- -- -- -- 4145 -- 5, F30, R5
2-1/2 x 13 TFL2513 ITT313 -- 18 2-9/16 13 2 -- 1-1/2 6 10d 2 10d x 1-1/2 1245 1645 1600 1700 1600 1230 -- 360 1, F27
TFL2514 ITS2.56/14, ITT314
-- 18 2-9/16 14 2 -- 1-1/2 6 10d 2 10d x 1-1/2 1245 1645 1600 1700 1600 1230 -- 360 1, F27
THO25140 MIT314 -- 18 2-9/16 14 2-3/8 -- 2 12 10d 2 10d x 1-1/2 2715 2715 2715 2715 2715 2280 -- 265 5, F30, R5 PHM2514 WPI314 -- 7/10 2-9/16 14 2-1/2 7 3 2 16d 2 10d x 1-1/2 -- 3570 3570 3080 2865 2865 -- -- 10, F16, R14 MPH2514 -- -- -- 12 2-1/2 14 2-1/2 7 3-3/4 2 16d duplex 2 10d x 1-1/2 -- -- -- -- -- -- 4145 -- 5, F30, R5 TFL2516 ITT316 -- 18 2-9/16 16 2 -- 1-1/2 6 10d 2 10d x 1-1/2 1245 1645 1600 1700 1600 1230 -- 360 1, F27
TFI316 LBV2.56/16, MIT316
-- 16 2-9/16 16 2-1/2 -- 2 6 16d 2 10d x 1-1/2 -- 2560 2235 2265 2560 1660 -- 360 2, F20, R12
PHM2516 WPI316 -- 7/10 2-9/16 16 2-1/2 7 3 2 16d 2 10d x 1-1/2 -- 3570 3570 3080 2865 2865 -- -- 10, F16, R14 MPH2516 -- -- -- 12 2-1/2 16 2-1/2 7 3-3/4 2 16d duplex 2 10d x 1-1/2 -- -- -- -- -- -- 4145 -- 5, F30, R5
TFI318 HIT318, LBV2.56/18, MIT318
-- 16 2-9/16 18 2-1/2 -- 2 6 16d 2 10d x 1-1/2 -- 2560 2235 2265 2560 1660 -- 360 2, F20, R12
MPH2518 -- -- x 12 2-1/2 18 2-1/2 7 3-3/4 2 16d duplex 2 10d x 1-1/2 -- -- -- -- -- -- 4145 -- 5, F30, R5
1) When I-joist is used as a header, all nails must be 10d x 1-1/2. 2) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 3) Duplex nails are No. 8 wire gauge (0.162˝ diameter) and 3-1/2˝ long, double headed nails. 4) NA16D-RS nails are 9 gauge (0.148˝ diameter) by 3-1/2˝ long, hardened ring shank nails. 5) Masonry compressive strength shall be minimum 1500 psi for MPH hangers. 6) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted 7) Some listed loads may be increased for short-term loading. Refer to code evaluation reports for USP Structural Connectors for details. 8) Minimum nail penetration shall be 1-1/2˝ for 10d nails and 1-5/8˝ for 16d nails. 9) When I-Joists with flanges less than 1-1/2˝ thick are used as headers, the published capacity shall be reduced. Contact USP for additional information. Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation. New products or updated product information are designated in bold font.
2-1/2 x 18
2-1/2 x 11-1/4
2-1/2 x 11-7/8
2-1/2 x 14
2-1/2 x 16
2-1/4 - 2-5/16 x 18
2-1/4 - 2-5/16 x 20
2-1/2 x 9-1/4
2-1/2 x 9-1/2
2-1/4 - 2-5/16 x 9-1/2
2-1/4 - 2-5/16 x 11-7/8
2-1/4 - 2-5/16 x 14
2-1/4 - 2-5/16 x 16
Web
Stif
fene
r Req
d.
Header Joist Header Material
1-800-328-5934 • www.USPconnectors.com128
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®EWP Top Mount Hanger Charts continued
continued on next page
H
L
TF
W D
USP2173-111
1-800-328-5934 • www.USPconnectors.com 129
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
Dimensions Fastener Schedule2,3,4,8 100% Allowable Loads (Lbs.)1,5,7 DF-L/SP
Uplift6
Joist SizeUSP
Stock No.
Ref. No.
Ste
el G
auge
W H D L TF Qty Type Qty Type DF-
L / S
P I-
Jois
t9
LV
L
PS
L
LS
L
DF-
L / S
P
SP
F
Mas
onry
160
% CodeRef.
TFI320 HIT320, LBV2.56/20, MIT320
-- 16 2-9/16 20 2-1/2 -- 2 6 16d 2 10d x 1-1/2 -- 2560 2235 2265 2560 1660 -- 360 2, F20, R12
MPH2520 -- -- x 12 2-1/2 20 2-1/2 7 3-3/4 2 16d duplex 2 10d x 1-1/2 -- -- -- -- -- -- 4145 -- 5, F30, R5
TFI322 HIT322, LBV2.56/22, WPI322
-- 16 2-9/16 22 2-1/2 -- 2 10 16d 2 10d x 1-1/2 -- 3245 2920 2950 3245 2345 -- 360 2, R12
MPH2522 -- -- x 12 2-1/2 22 2-1/2 7 3-3/4 2 16d duplex 2 10d x 1-1/2 -- -- -- -- -- -- 4145 -- 5, F30, R5
TFI324 HIT324, LBV2.56/24, WPI324
-- 16 2-9/16 24 2-1/2 -- 2 10 16d 2 10d x 1-1/2 -- 3245 2920 2950 3245 2345 -- 360 2, F20, R12
MPH2524 -- -- x 12 2-1/2 24 2-1/2 7 3-3/4 2 16d duplex 2 10d x 1-1/2 -- -- -- -- -- -- 4145 -- 5, F30, R5
TFI326 HIT326, LBV2.56/26, WPI326
-- 16 2-9/16 26 2-1/2 -- 2 10 16d 2 10d x 1-1/2 -- 3245 2920 2950 3245 2345 -- 360 2, F20, R12
MPH2526 -- -- x 12 2-1/2 26 2-1/2 7 3-3/4 2 16d duplex 2 10d x 1-1/2 -- -- -- -- -- -- 4145 -- 5, F30, R5 2-5/8 x 9-1/2 THO26950 -- -- -- 18 2-11/16 9-1/2 2-3/8 -- 2 10 10d 2 10d x 1-1/2 1625 1625 1625 1625 1625 1365 -- 265 5, F30, R5 2-5/8 x 11-7/8 THO26118 -- -- -- 16 2-11/16 11-7/8 2-3/8 -- 2 10 10d 2 10d x 1-1/2 1835 1835 1835 1835 1835 865 -- 265 5, F30, R5 2-5/8 x 14 THO26140 -- -- -- 18 2-11/16 14 2-3/8 -- 2 12 10d 2 10d x 1-1/2 2715 2715 2715 2715 2715 2300 -- 265 5, F30, R5 2-5/8 x 16 THO26160 -- -- -- 18 2-11/16 16 2-3/8 -- 2 12 10d 2 10d x 1-1/2 2715 2715 2715 2715 2715 2300 -- 265 5, F30, R5
PHXU27925 HWU2.75/9.25 -- 7 2-3/4 9-1/4 3-1/4 10 2-1/2 8 16d 6 10d x 1-1/2 -- 6020 5785 6020 5285 3590 -- 970 8, F14, R9 HLBH27925 GLTV2.75/9.25 x 7 2-3/4 9-1/4 6 12 2-3/4 15 NA16D-RS 6 10d x 1-1/2 -- 10225 10540 9600 9600 8915 -- 1380 10, F16, R14 PHXU2795 -- -- -- 7 2-3/4 9-1/2 3-1/4 10 2-1/2 8 16d 6 10d x 1-1/2 -- 6020 5785 6020 5285 3590 -- 970 8, F14, R9 HLBH2795 GLTV2.75/9.5 x 7 2-3/4 9-1/2 6 12 2-3/4 15 NA16D-RS 6 10d x 1-1/2 -- 10225 10540 9600 9600 8915 -- 1380 10, F16, R14 PHXU27112 -- -- -- 7 2-3/4 11-1/4 3-1/4 10 2-1/2 8 16d 6 10d x 1-1/2 -- 6020 5785 6020 5285 3590 -- 970 8, F14, R9 HLBH27112 GLTV2.75/11.25 x 7 2-3/4 11-1/4 6 12 2-3/4 15 NA16D-RS 6 10d x 1-1/2 -- 10225 10540 9600 9600 8915 -- 1380 10, F16, R14 PHXU27118 -- -- -- 7 2-3/4 11-7/8 3-1/4 10 2-1/2 8 16d 6 10d x 1-1/2 -- 6020 5785 6020 5285 3590 -- 970 8, F14, R9 HLBH27118 GLTV2.75/11.88 x 7 2-3/4 11-7/8 6 12 2-3/4 15 NA16D-RS 6 10d x 1-1/2 -- 10225 10540 9600 9600 8915 -- 1380 10, F16, R14 PHXU2714 -- -- -- 7 2-3/4 14 3-1/4 10 2-1/2 8 16d 6 10d x 1-1/2 -- 6020 5785 6020 5285 3590 -- 970 8, F14, R9 HLBH2714 GLTV2.75/14 x 7 2-3/4 14 6 12 2-3/4 15 NA16D-RS 6 10d x 1-1/2 -- 10225 10540 9600 9600 8915 -- 1380 10, F16, R14 PHXU2716 -- -- -- 7 2-3/4 16 3-1/4 10 2-1/2 8 16d 6 10d x 1-1/2 -- 6020 5785 6020 5285 3590 -- 970 8, F14, R9 HLBH2716 GLTV2.75/16 x 7 2-3/4 16 6 12 2-3/4 15 NA16D-RS 6 10d x 1-1/2 -- 10225 10540 9600 9600 8915 -- 1380 10, F16, R14
BPH31925 LBV3.12/9.25 x 12 3-1/8 9-1/4 3 -- 2-3/32 10 16d 4 10d -- 3440 3510 3775 3440 2815 -- 625 10, F16, R14
PHXU31925 WP29.25-2 x 7 3-1/8 9-1/4 3-1/4 10 2-1/2 8 16d 6 10d x 1-1/2 -- 6020 5785 6020 5285 3590 -- 970 130
MPH210-2 WM210-2, WM29.25-2
x 12 3-1/8 9-1/4 2-1/2 7 3-3/4 2 16d duplex 2 10d -- -- -- -- -- -- 4280 -- 5, F30, R5
THO15950-2 MIT29.5-2 x 16 3-1/16 9-1/2 2-3/8 -- 1-1/2 10 16d 6 10d 2630 2330 2490 2490 2500 1860 -- 1115 5, F30, R5 BPH3195 LBV3.12/9.5 x 12 3-1/8 9-1/2 3 -- 2-3/32 10 16d 4 10d -- 3440 3510 3775 3440 2815 -- 625 10, F16, R14 PHXU3195 WP29.5-2 x 7 3-1/8 9-1/2 3-1/4 10 2-1/2 8 16d 6 10d x 1-1/2 -- 6020 5785 6020 5285 3590 -- 970 130 MPH1595-2 WM29.5-2 x 12 3-1/8 9-1/2 2-1/2 7 3-3/4 2 16d duplex 2 10d -- -- -- -- -- -- 4280 -- 5, F30, R5 BPH31112 LBV3.12/11.25 x 12 3-1/8 11-1/4 3 -- 2-3/32 10 16d 4 10d -- 3440 3510 3775 3440 2815 -- 625 10, F16, R14 PHXU31112 WP211.25-2 x 7 3-1/8 11-1/4 3-1/4 10 2-1/2 8 16d 6 10d x 1-1/2 -- 6020 5785 6020 5285 3590 -- 970 130 MPH15112-2 WM211.25-2 x 12 3-1/8 11-1/4 2-1/2 7 3-3/4 2 16d duplex 2 10d -- -- -- -- -- -- 4280 -- 5, F30, R5 THO15118-2 MIT211.88-2 x 16 3-1/16 11-7/8 2-3/8 -- 1-1/2 10 16d 6 10d 2630 2330 2465 2465 2490 1845 -- 1115 5, F30, R5 BPH31118 LBV3.12/11.88 x 12 3-1/8 11-7/8 3 -- 2-3/32 10 16d 4 10d -- 3440 3510 3775 3440 2815 -- 625 10, F16, R14 PHXU31118 WP211.88-2 x 7 3-1/8 11-7/8 3-1/4 10 2-1/2 8 16d 6 10d x 1-1/2 -- 6020 5785 6020 5285 3590 -- 970 130 MPH15118-2 WM211.88-2 x 12 3-1/8 11-7/8 2-1/2 7 3-3/4 2 16d duplex 2 10d -- -- -- -- -- -- 4280 -- 5, F30, R5 BPH3114 LBV3.12/14 x 12 3-1/8 14 3 -- 2-3/32 10 16d 4 10d -- 3440 3510 3775 3440 2815 -- 625 10, F16, R14 PHXU3114 -- -- x 7 3-1/8 14 3-1/4 10 2-1/2 8 16d 6 10d x 1-1/2 -- 6020 5785 6020 5285 3590 -- 970 130
THO35925 ITT49.25 -- 16 3-9/16 9-1/4 2-3/8 -- 2-1/2 10 10d 2 10d x 1-1/2 2050 2050 2050 2050 2050 1720 -- 265 5, F30, R5
BPH35925 BA410, LBV3.56/9.25
x 12 3-9/16 9-1/4 2-3/8 -- 2-3/8 10 16d 4 10d -- 3485 3510 3775 3485 3280 -- 815
PHM35925 WPI49.25 x 7/10 3-5/8 9-1/4 2-1/2 7 3 2 16d 2 10d -- 3745 3570 3080 3255 3255 -- --
PHXU35925 HB3.56/9.25, HWI49.25, HWU3.56/9.25
x 7 3-9/16 9-1/4 3-1/4 10 2-1/2 8 16d 6 10d -- 6650 5785 6420 5285 3590 -- 1290 8, F14, R9
HLBH35925 -- -- x 7 3-5/8 9-1/4 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10565 9600 9600 8915 -- 1420 10, F16, R14 MPH410 WM410 -- 12 3-9/16 9-1/4 2-1/2 7 3-3/4 2 16d duplex 2 10d -- -- -- -- -- -- 4280 -- 5, F30, R5
3-1/2 x 9-1/4
10, F16, R14
3 x 9-1/2
3 x 11-1/4
3 x 11-7/8
3 x 14
2-11/16 x 11-7/8
2-11/16 x 14
2-11/16 x 16
3 x 9-1/4
2-1/2 x 26
2-11/16 x 9-1/4
2-11/16 x 9-1/2
2-11/16 x 11-1/4
Header Material
2-1/2 x 20
2-1/2 x 22
2-1/2 x 24
Web
Stif
fene
r Req
d.
Header Joist
EWP Top Mount Hanger Charts continued
continued on next page
1-800-328-5934 • www.USPconnectors.com130
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
continued on next page
EWP Top Mount Hanger Charts continued
Dimensions Fastener Schedule2,3,4,8 100% Allowable Loads (Lbs.) 1,5,7 DF-L/SP
Uplift6
Joist SizeUSP
Stock No.
Ref. No.
Ste
el G
auge
W H D L TF Qty Type Qty Type DF-
L / S
P I-
Jois
t9
LVL
PSL
LSL
DF-
L / S
P
SPF
Mas
onry
160
% CodeRef.
3-1/2 x 9-3/8 THO35938 ITT49.37 -- 16 3-9/16 9-3/8 2-3/8 -- 2-9/16 10 10d 2 10d x 1-1/2 2050 2050 2050 2050 2050 1720 -- 265 5, F30, R5
THO35950 ITT49.5 -- 16 3-9/16 9-1/2 2-3/8 -- 2-7/16 10 10d 2 10d x 1-1/2 2050 2050 2050 2050 2050 1720 -- 265 5, F30, R5 THO17950-2 MIT49.5 x 16 3-9/16 9-1/2 2-3/8 -- 1-9/16 10 16d 6 10d 2630 2330 2555 2555 2580 1905 -- 1115 5, F30, R5 BPH3595 LBV3.56/9.5 x 12 3-9/16 9-1/2 2-3/8 -- 2-3/8 10 16d 4 10d -- 3485 3510 3775 3485 3280 -- 815 PHM3595 WPI49.5 x 7/10 3-5/8 9-1/2 2-1/2 7 3 2 16d 2 10d -- 3745 3570 3080 3255 3255 -- --
PHXU3595
GLTV3.59, HB3.56/9.5, HWI49.5, HWU3.56/9.5
x 7 3-9/16 9-1/2 3-1/4 10 2-1/2 8 16d 6 10d -- 6650 5785 6420 5285 3590 -- 1290 8, F14, R9
HLBH3595 HGLTV3.59 x 7 3-5/8 9-1/2 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10565 9600 9600 8915 -- 1420 10, F16, R14 MPH1795-2 WM3.56/9.5 -- 12 3-5/8 9-1/2 2-1/2 7 3-3/4 2 16d duplex 2 10d -- -- -- -- -- -- 4280 -- 5, F30, R5 THO35112 ITT411.25 -- 16 3-9/16 11-1/4 2-3/8 -- 2-1/2 10 10d 2 10d x 1-1/2 2050 2050 2050 2050 2050 1720 -- 265 5, F30, R5
BPH35112 BA412, LBV3.56/11.25
x 12 3-9/16 11-1/4 2-3/8 -- 2-3/8 10 16d 4 10d -- 3485 3510 3775 3485 3280 -- 815 10, F16, R14
PHM35112 WPI411.25 x 7/10 3-5/8 11-1/4 2-1/2 7 3 2 16d 2 10d -- 3745 3570 3080 3255 3255 -- -- 10, F16, R14
PHXU35112
GLTV3.56/11.25, HB3.56/11.25, HWI411.25, HWU3.56/11.25
x 7 3-9/16 11-1/4 3-1/4 10 2-1/2 8 16d 6 10d -- 6650 5785 6420 5285 3590 -- 1290 8, F14, R9
HLBH35112 HGLTV3.56/11.25 x 7 3-5/8 11-1/4 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10565 9600 9600 8915 -- 1420 10, F16, R14
MPH412 WM412 -- 12 3-9/16 11-1/4 2-1/2 7 3-3/4 2 16d duplex 2 10d -- -- -- -- -- -- 4280 -- 5, F30, R5
THO35118 ITT411.88 -- 18 3-9/16 11-7/8 2-3/8 -- 2-1/2 10 10d 2 10d x 1-1/2 2050 2050 2050 2050 2050 1720 -- 265 5, F30, R5 THO17118-2 MIT411.88 x 16 3-9/16 11-7/8 2-3/8 -- 1-9/16 10 16d 6 10d 2630 2330 2355 2355 2375 1765 -- 1115 5, F30, R5
BPH35118 BA3.56/11.88, LBV3.56/11.88
x 12 3-9/16 11-7/8 2-3/8 -- 2-3/8 10 16d 4 10d -- 3485 3510 3775 3485 3280 -- 815
PHM35118 WPI411.88 x 7/10 3-5/8 11-7/8 2-1/2 7 3 2 16d 2 10d -- 3745 3570 3080 3255 3255 -- --
PHXU35118
GLTV3.511, HB3.56/11.88, HWI411.88, HWU3.56/11.88, WPU3.56/11.88
x 7 3-9/16 11-7/8 3-1/4 10 2-1/2 8 16d 6 10d -- 6650 5785 6420 5285 3590 -- 1290 8, F14, R9
HLBH35118 HGLTV3.511 x 7 3-5/8 11-7/8 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10565 9600 9600 8915 -- 1420 10, F16, R14 MPH17118-2 WM3.56/11.88 -- 12 3-5/8 11-7/8 2-1/2 7 3-3/4 2 16d duplex 2 10d -- -- -- -- -- -- 4280 -- 5, F30, R5 THO35120 -- -- -- 18 3-9/16 12 2-3/8 -- 2-1/2 10 10d 2 10d x 1-1/2 2050 2050 2050 2050 2050 1720 -- 265 5, F30, R5
BPH3512 HWI412, LBV3.56/12
x 12 3-9/16 12 2-3/4 -- 2-1/32 10 16d 6 10d -- 3430 3510 3775 3430 3280 -- 1140 10, F16, R14
PHXU3512 GLTV3.512, HB3.56/12
x 7 3-9/16 12 3-1/4 10 2-1/2 8 16d 6 10d -- 6650 5785 6420 5285 3590 -- 1290 8, F14, R9
HLBH3512 HGLTV3.512 x 7 3-5/8 12 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10565 9600 9600 8915 -- 1420 10, F16, R14 MPH3512 WMI412 -- 12 3-1/2 12 2-1/2 7 3-3/4 2 16d duplex 2 10d -- -- -- -- -- -- 4280 -- 5, F30, R5
3-1/2 x 13 THO35130 ITT413 -- 18 3-9/16 13 2-3/8 -- 2-1/2 10 10d 2 10d x 1-1/2 2050 2050 2050 2050 2050 1720 -- 265 5, F30, R5 THO35140 ITT414 -- 18 3-9/16 14 2-3/8 -- 2-1/2 12 10d 2 10d x 1-1/2 2715 2715 2715 2715 2715 2280 -- 265 5, F30, R5 TFI414 MIT414 -- 16 3-9/16 14 2-1/2 -- 2-1/8 6 16d 2 10d x 1-1/2 -- 2560 2235 2265 2560 1660 -- 360 2, F20, R12
BPH3514 B3.56/14, BA3.56/14, LBV3.56/14
x 12 3-9/16 14 2-3/4 -- 2-1/32 10 16d 6 10d -- 3430 3510 3775 3430 3280 -- 1140
PHM3514 WPI414 x 7/10 3-5/8 14 2-1/2 7 3 2 16d 2 10d -- 3745 3570 3080 3255 3255 -- --
PHXU3514
GLTV3.514, HB3.56/14, HWI414, HWU3.56/14, WPU3.56/14
x 7 3-9/16 14 3-1/4 10 2-1/2 8 16d 6 10d -- 6650 5785 6420 5285 3590 -- 1290 8, F14, R9
HLBH3514 HGLTV3.514 x 7 3-5/8 14 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10565 9600 9600 8915 -- 1420 10, F16, R14 MPH3514 WMI414 -- 12 3-1/2 14 2-1/2 7 3-3/4 2 16d duplex 2 10d -- -- -- -- -- -- 4280 -- 5, F30, R5
1) When I-joist is used as a header, all nails must be 10d x 1-1/2. 2) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 3) Duplex nails are No. 8 wire gauge (0.162˝ diameter) and 3-1/2˝ long, double headed nails. 4) NA16D-RS nails are 9 gauge (0.148˝ diameter) by 3-1/2˝ long, hardened ring shank nails. 5) Masonry compressive strength shall be minimum 1500 psi for MPH hangers. 6) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted 7) Some listed loads may be increased for short-term loading. Refer to code evaluation reports for USP Structural Connectors for details. 8) Minimum nail penetration shall be 1-1/2˝ for 10d nails and 1-5/8˝ for 16d nails. 9) When I-Joists with flanges less than 1-1/2˝ thick are used as headers, the published capacity shall be reduced. Contact USP for additional information. Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation. New products or updated product information are designated in bold font.
3-1/2 x 12
3-1/2 x 14
10, F16, R14
3-1/2 x 9-1/2
10, F16, R14
3-1/2 x 11-1/4
3-1/2 x 11-7/8
10, F16, R14
Web
Stif
fene
r Req
d.
Header Joist Header Material
H
L
TF
W D
Dimensions Fastener Schedule2,3,4,8 100% Allowable Loads (Lbs.)1,5,7 DF-L/SP
Uplift6
Joist SizeUSP
Stock No.
Ref. No.
Ste
el G
auge
W H D L TF Qty Type Qty Type DF-
L / S
P I-
Jois
t9
LVL
PSL
LSL
DF-
L / S
P
SPF
Mas
onry
160
% CodeRef.
THO35160 ITT416 -- 18 3-9/16 16 2-3/8 -- 2-1/2 12 10d 2 10d x 1-1/2 2715 2715 2715 2715 2715 2280 -- 265 5, F30, R5 TFI416 MIT416 -- 16 3-9/16 16 2-1/2 -- 2-1/8 6 16d 2 10d x 1-1/2 -- 2560 2235 2265 2560 1660 -- 360 2, F20, R12
BPH3516 B3.56/16, BA3.56/16, LBV3.56/16
x 12 3-9/16 16 2-3/4 -- 2-1/32 10 16d 6 10d -- 3430 3510 3775 3430 3280 -- 1140
PHM3516 WPI416 x 7/10 3-5/8 16 2-1/2 7 3 2 16d 2 10d -- 3745 3570 3080 3255 3255 -- --
PHXU3516
GLTV3.516, HB3.56/16, HWI416, HWU3.56/16, WPU3.56/16
x 7 3-9/16 16 3-1/4 10 2-1/2 8 16d 6 10d -- 6650 5785 6420 5285 3590 -- 1290 8, F14, R9
HLBH3516 HGLTV3.516 x 7 3-5/8 16 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10565 9600 9600 8915 -- 1420 10, F16, R14 MPH3516 WMI416 -- 12 3-1/2 16 2-1/2 7 3-3/4 2 16d duplex 2 10d -- -- -- -- -- -- 4280 -- 5, F30, R5
TFI418 HIT418, MIT418
-- 16 3-9/16 18 2-1/2 -- 2-1/8 6 16d 2 10d x 1-1/2 -- 2560 2235 2265 2560 1660 -- 360 2, F20, R12
BPH3518 LBV3.56/18 x 12 3-9/16 18 2-3/4 -- 2-1/32 10 16d 6 10d -- 3430 3510 3775 3430 3280 -- 1140
PHM3518 WPI418 x 7/10 3-5/8 18 2-1/2 7 3 2 16d 2 10d -- 3745 3570 3080 3255 3255 -- --
PHXU3518
GLTV3.518, HB3.56/18, HWI418, HWU3.56/18, WPU3.56/18
x 7 3-9/16 18 3-1/4 10 2-1/2 8 16d 6 10d -- 6650 5785 6420 5285 3590 -- 1290 8, F14, R9
HLBH3518 HGLTV3.518 x 7 3-5/8 18 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10565 9600 9600 8915 -- 1420 10, F16, R14
MPH3518 WMI418 x 12 3-1/2 18 2-1/2 7 3-3/4 2 16d duplex 2 10d -- -- -- -- -- -- 4280 -- 5, F30, R5
TFI420 MIT420 -- 16 3-9/16 20 2-1/2 -- 2-1/8 6 16d 2 10d x 1-1/2 -- 2560 2235 2265 2560 1660 -- 360 2, F20, R12
BPH3520 HIT420, LBV3.56/20
x 12 3-9/16 20 2-3/4 -- 2-1/32 10 16d 6 10d -- 3430 3510 3775 3430 3280 -- 1140
PHM3520 WPI420 x 7/10 3-5/8 20 2-1/2 7 3 2 16d 2 10d -- 3745 3570 3080 3255 3255 -- --
PHXU3520 HB3.56/20, HWI420, WPU3.56/20
x 7 3-9/16 20 3-1/4 10 2-1/2 8 16d 6 10d -- 6650 5785 6420 5285 3590 -- 1290 8, F14, R9
HLBH3520 -- -- x 7 3-5/8 20 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10565 9600 9600 8915 -- 1420 10, F16, R14 MPH3520 WMI420 x 12 3-1/2 20 2-1/2 7 3-3/4 2 16d duplex 2 10d -- -- -- -- -- -- 4280 -- 5, F30, R5 TFI422 HIT422 -- 16 3-9/16 22 2-1/2 -- 2-1/8 10 16d 2 10d x 1-1/2 -- 3245 2920 2950 3245 2345 -- 360 2, F20, R12
BPH3522 HIT3522, LBV3.56/22
x 12 3-9/16 22 2-3/4 -- 2-1/32 10 16d 6 10d -- 3430 3510 3775 3430 3280 -- 1140
PHM3522 HWI422, WPI422
x 7/10 3-5/8 22 2-1/2 7 3 2 16d 2 10d -- 3745 3570 3080 3255 3255 -- --
PHXU3522 HB3.56/22, WPU3.56/22
x 7 3-9/16 22 3-1/4 10 2-1/2 8 16d 6 10d -- 6650 5785 6420 5285 3590 -- 1290 8, F14, R9
TFI424 HIT424, LBV3.56/24
-- 16 3-9/16 24 2-1/2 -- 2-1/8 10 16d 2 10d x 1-1/2 -- 3245 2920 2950 3245 2345 -- 360 2, F20, R12
BPH3524 -- -- x 12 3-9/16 24 2-3/4 -- 2-1/32 10 16d 6 10d -- 3430 3510 3775 3430 3280 -- 1140
PHM3524 HWI424, WPI424
x 7/10 3-5/8 24 2-1/2 7 3 2 16d 2 10d -- 3745 3570 3080 3255 3255 -- --
PHXU3524 HB3.56/24, WPU3.56/24
x 7 3-9/16 24 3-1/4 10 2-1/2 8 16d 6 10d -- 6650 5785 6420 5285 3590 -- 1290 8, F14, R9
TFI426 HIT426 -- 16 3-9/16 26 2-1/2 -- 2-1/8 10 16d 2 10d x 1-1/2 -- 3245 2920 2950 3245 2345 -- 360 2, F20, R12 BPH3526 LBV3.56/26 x 12 3-9/16 26 2-3/4 -- 2-1/32 10 16d 6 10d -- 3430 3510 3775 3430 3280 -- 1140
PHM3526 HWI426, WPI426
x 7/10 3-5/8 26 2-1/2 7 3 2 16d 2 10d -- 3745 3570 3080 3255 3255 -- --
PHXU3526 HB3.56/26, WPU3.56/26
x 7 3-9/16 26 3-1/4 10 2-1/2 8 16d 6 10d -- 6650 5785 6420 5285 3590 -- 1290 8, F14, R9
BPH3528 LBV3.56/28 x 12 3-9/16 28 2-3/4 -- 2-1/32 10 16d 6 10d -- 3430 3510 3775 3430 3280 -- 1140
PHM3528 HWI428, WPI428
x 7/10 3-5/8 28 2-1/2 7 3 2 16d 2 10d -- 3745 3570 3080 3255 3255 -- --
PHXU3528 HB3.56/28, WPU3.56/28
x 7 3-9/16 28 3-1/4 10 2-1/2 8 16d 6 10d -- 6650 5785 6420 5285 3590 -- 1290 8, F14, R9
BPH3530 LBV3.56/30 x 12 3-9/16 30 2-3/4 -- 2-1/32 10 16d 6 10d -- 3430 3510 3775 3430 3280 -- 1140
PHM3530 HWI430, WPI430
x 7/10 3-5/8 30 2-1/2 7 3 2 16d 2 10d -- 3745 3570 3080 3255 3255 -- --
PHXU3530 HB3.56/30 x 7 3-9/16 30 3-1/4 10 2-1/2 8 16d 6 10d -- 6650 5785 6420 5285 3590 -- 1290 8, F14, R9 BPH3532 -- -- x 12 3-9/16 32 2-3/4 -- 2-1/32 10 16d 6 10d -- 3430 3510 3775 3430 3280 -- 1140
PHM3532 HWI432, WPI432
x 7/10 3-5/8 32 2-1/2 7 3 2 16d 2 10d -- 3745 3570 3080 3255 3255 -- --
PHXU3532 -- -- x 7 3-9/16 32 3-1/4 10 2-1/2 8 16d 6 10d -- 6650 5785 6420 5285 3590 -- 1290 130
THO20950-2 LBV4.12/9.5, LBV4.28/9.5, MIT4.28/9.5
x 16 4-3/16 9-1/2 3 -- 2 10 16d 6 10d 2630 2330 2665 2665 2665 2240 -- 1115 5, F30, R5
PHM4295 -- -- x 7/10 4-3/16 9-1/2 2-1/2 7 3 2 16d 2 10d -- 3745 3570 3080 3255 3255 -- -- 130
3-1/2 x 3210, F16, R14
4 - 4-3/16 x 9-1/2
3-1/2 x 28
10, F16, R14
3-1/2 x 3010, F16, R14
3-1/2 x 24 10, F16, R14
3-1/2 x 2610, F16, R14
3-1/2 x 20
10, F16, R14
3-1/2 x 2210, F16, R14
3-1/2 x 16
10, F16, R14
3-1/2 x 18
10, F16, R14
Web
Stif
fene
r Req
d.
Header Joist Header Material
USP2173-111
1-800-328-5934 • www.USPconnectors.com 131
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®EWP Top Mount Hanger Charts continued
continued on next page
Dimensions Fastener Schedule2,3,4,8 100% Allowable Loads (Lbs.) 1,5,7 DF-L/SP
Uplift6
Joist SizeUSP
Stock No.
Ref. No.
Ste
el G
auge
W H D L TF Qty Type Qty Type DF-
L / S
P I-
Jois
t9
LVL
PSL
LSL
DF-
L / S
P
SPF
Mas
onry
160
% CodeRef.
3-1/2 x 9-3/8 THO35938 ITT49.37 -- 16 3-9/16 9-3/8 2-3/8 -- 2-9/16 10 10d 2 10d x 1-1/2 2050 2050 2050 2050 2050 1720 -- 265 5, F30, R5
THO35950 ITT49.5 -- 16 3-9/16 9-1/2 2-3/8 -- 2-7/16 10 10d 2 10d x 1-1/2 2050 2050 2050 2050 2050 1720 -- 265 5, F30, R5 THO17950-2 MIT49.5 x 16 3-9/16 9-1/2 2-3/8 -- 1-9/16 10 16d 6 10d 2630 2330 2555 2555 2580 1905 -- 1115 5, F30, R5 BPH3595 LBV3.56/9.5 x 12 3-9/16 9-1/2 2-3/8 -- 2-3/8 10 16d 4 10d -- 3485 3510 3775 3485 3280 -- 815 PHM3595 WPI49.5 x 7/10 3-5/8 9-1/2 2-1/2 7 3 2 16d 2 10d -- 3745 3570 3080 3255 3255 -- --
PHXU3595 x 7 3-9/16 9-1/2 3-1/4 10 2-1/2 8 16d 6 10d -- 6650 5785 6420 5285 3590 -- 1290 8, F14, R9
HLBH3595 HGLTV3.59 x 7 3-5/8 9-1/2 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10565 9600 9600 8915 -- 1420 10, F16, R14 MPH1795-2 WM3.56/9.5 -- 12 3-5/8 9-1/2 2-1/2 7 3-3/4 2 16d duplex 2 10d -- -- -- -- -- -- 4280 -- 5, F30, R5 THO35112 ITT411.25 -- 16 3-9/16 11-1/4 2-3/8 -- 2-1/2 10 10d 2 10d x 1-1/2 2050 2050 2050 2050 2050 1720 -- 265 5, F30, R5
BPH35112 x 12 3-9/16 11-1/4 2-3/8 -- 2-3/8 10 16d 4 10d -- 3485 3510 3775 3485 3280 -- 815 10, F16, R14
PHM35112 WPI411.25 x 7/10 3-5/8 11-1/4 2-1/2 7 3 2 16d 2 10d -- 3745 3570 3080 3255 3255 -- -- 10, F16, R14
PHXU35112 x 7 3-9/16 11-1/4 3-1/4 10 2-1/2 8 16d 6 10d -- 6650 5785 6420 5285 3590 -- 1290 8, F14, R9
HLBH35112 x 7 3-5/8 11-1/4 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10565 9600 9600 8915 -- 1420 10, F16, R14
MPH412 WM412 -- 12 3-9/16 11-1/4 2-1/2 7 3-3/4 2 16d duplex 2 10d -- -- -- -- -- -- 4280 -- 5, F30, R5
THO35118 ITT411.88 -- 18 3-9/16 11-7/8 2-3/8 -- 2-1/2 10 10d 2 10d x 1-1/2 2050 2050 2050 2050 2050 1720 -- 265 5, F30, R5 THO17118-2 MIT411.88 x 16 3-9/16 11-7/8 2-3/8 -- 1-9/16 10 16d 6 10d 2630 2330 2355 2355 2375 1765 -- 1115 5, F30, R5
BPH35118 x 12 3-9/16 11-7/8 2-3/8 -- 2-3/8 10 16d 4 10d -- 3485 3510 3775 3485 3280 -- 815
PHM35118 WPI411.88 x 7/10 3-5/8 11-7/8 2-1/2 7 3 2 16d 2 10d -- 3745 3570 3080 3255 3255 -- --
PHXU35118 x 7 3-9/16 11-7/8 3-1/4 10 2-1/2 8 16d 6 10d -- 6650 5785 6420 5285 3590 -- 1290 8, F14, R9
HLBH35118 HGLTV3.511 x 7 3-5/8 11-7/8 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10565 9600 9600 8915 -- 1420 10, F16, R14 MPH17118-2 WM3.56/11.88 -- 12 3-5/8 11-7/8 2-1/2 7 3-3/4 2 16d duplex 2 10d -- -- -- -- -- -- 4280 -- 5, F30, R5 THO35120 -- -- -- 18 3-9/16 12 2-3/8 -- 2-1/2 10 10d 2 10d x 1-1/2 2050 2050 2050 2050 2050 1720 -- 265 5, F30, R5
BPH3512 x 12 3-9/16 12 2-3/4 -- 2-1/32 10 16d 6 10d -- 3430 3510 3775 3430 3280 -- 1140 10, F16, R14
PHXU3512 x 7 3-9/16 12 3-1/4 10 2-1/2 8 16d 6 10d -- 6650 5785 6420 5285 3590 -- 1290 8, F14, R9
HLBH3512 HGLTV3.512 x 7 3-5/8 12 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10565 9600 9600 8915 -- 1420 10, F16, R14 MPH3512 WMI412 -- 12 3-1/2 12 2-1/2 7 3-3/4 2 16d duplex 2 10d -- -- -- -- -- -- 4280 -- 5, F30, R5
3-1/2 x 13 THO35130 ITT413 -- 18 3-9/16 13 2-3/8 -- 2-1/2 10 10d 2 10d x 1-1/2 2050 2050 2050 2050 2050 1720 -- 265 5, F30, R5 THO35140 ITT414 -- 18 3-9/16 14 2-3/8 -- 2-1/2 12 10d 2 10d x 1-1/2 2715 2715 2715 2715 2715 2280 -- 265 5, F30, R5 TFI414 MIT414 -- 16 3-9/16 14 2-1/2 -- 2-1/8 6 16d 2 10d x 1-1/2 -- 2560 2235 2265 2560 1660 -- 360 2, F20, R12
BPH3514 x 12 3-9/16 14 2-3/4 -- 2-1/32 10 16d 6 10d -- 3430 3510 3775 3430 3280 -- 1140
PHM3514 WPI414 x 7/10 3-5/8 14 2-1/2 7 3 2 16d 2 10d -- 3745 3570 3080 3255 3255 -- --
PHXU3514 x 7 3-9/16 14 3-1/4 10 2-1/2 8 16d 6 10d -- 6650 5785 6420 5285 3590 -- 1290 8, F14, R9
HLBH3514 HGLTV3.514 x 7 3-5/8 14 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10565 9600 9600 8915 -- 1420 10, F16, R14 MPH3514 WMI414 -- 12 3-1/2 14 2-1/2 7 3-3/4 2 16d duplex 2 10d -- -- -- -- -- -- 4280 -- 5, F30, R5
1) When I-joist is used as a header, all nails must be 10d x 1-1/2. 2) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 3) Duplex nails are No. 8 wire gauge (0.162˝ diameter) and 3-1/2˝ long, double headed nails. 4) NA16D-RS nails are 9 gauge (0.148˝ diameter) by 3-1/2˝ long, hardened ring shank nails. 5) Masonry compressive strength shall be minimum 1500 psi for MPH hangers. 6) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted 7) Some listed loads may be increased for short-term loading. Refer to code evaluation reports for USP Structural Connectors for details. 8) Minimum nail penetration shall be 1-1/2˝ for 10d nails and 1-5/8˝ for 16d nails. 9) When I-Joists with flanges less than 1-1/2˝ thick are used as headers, the published capacity shall be reduced. Contact USP for additional information. Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation. New products or updated product information are designated in bold font.
Web
Stif
fene
r Req
d.
1-800-328-5934 • www.USPconnectors.com132
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®EWP Top Mount Hanger Charts continued
continued on next page
Dimensions Fastener Schedule2,3,4,8 100% Allowable Loads (Lbs.) 1,5,7 DF-L/SP
Uplift6
Joist SizeUSP
Stock No.
Ref. No.
Ste
el G
auge
W H D L TF Qty Type Qty Type DF-
L / S
P I-
Jois
t9
LVL
PSL
LSL
DF-
L / S
P
SPF
Mas
onry
160
% CodeRef.
THO20118-2 LBV4.12/11.88, LBV4.28/11.88, MIT4.28/11.88
x 16 4-3/16 11-7/8 3 -- 2 10 16d 6 10d 2630 2330 2700 2700 2700 2270 -- 1115 5, F30, R5
PHM42118 -- -- x 7/10 4-3/16 11-7/8 2-1/2 7 3 2 16d 2 10d -- 3745 3570 3080 3255 3255 -- -- 130
THO20140-2 LBV4.12/14, LBV4.28/14, MIT4.28/14
x 12 4-3/16 14 3 -- 1-15/16 10 16d 6 10d 2630 2330 3700 3700 3700 2765 -- 1175 5, F30, R5
PHM4214 -- -- x 7/10 4-3/16 14 2-1/2 7 3 2 16d 2 10d -- 3745 3570 3080 3255 3255 -- -- 130
THO20160-2 LBV4.12/16, LBV4.28/16
x 12 4-3/16 16 3 -- 1-15/16 10 16d 6 10d 2630 2330 3700 3700 3700 2765 -- 1175 5, F30, R5
PHM4216 -- -- x 7/10 4-3/16 16 2-1/2 7 3 2 16d 2 10d -- 3745 3570 3080 3255 3255 -- -- 130
THO23950-2 LBV4.75/9.5, MIT359.5-2
x 12 4-3/4 9-1/2 3 -- 2 10 16d 6 10d 2630 3535 3635 3635 3665 2675 -- 11755,
F30, R5
PHM2395-2 WP359.5-2 x 7/10 4-3/4 9-1/2 2-1/2 7 3 2 16d 2 10d -- 3745 3255 2965 3255 3255 -- -- 10, F16, R14
THO23118-2 LBV4.75/11.88, MIT3511.88-2
x 12 4-3/4 11-7/8 3 -- 2-1/8 10 16d 6 10d 2630 3535 3665 3665 3665 3005 -- 11755,
F30, R5
PHM23118-2 WP3511.88-2 x 7/10 4-3/4 11-7/8 2-1/2 7 3 2 16d 2 10d -- 3745 3255 2965 3255 3255 -- -- 10, F16, R14
MPH23118-2 WM3511.88-2 x 12 4-5/8 11-7/8 2-1/2 7 3-3/4 2 16d duplex 2 10d -- -- -- -- -- -- 4280 -- 5, F30, R5
THO23140-2 LBV4.75/14, MIT3514-2
x 12 4-3/4 14 3 -- 2-1/8 12 16d 6 10d 2630 3535 4405 4405 4450 3265 -- 11755,
F30, R5
MPH2314-2 WM3514-2 x 12 4-5/8 14 2-1/2 7 3-3/4 2 16d duplex 2 10d -- -- -- -- -- -- 4280 -- 5, F30, R5
THO23160-2 LBV4.75/16 x 12 4-3/4 16 3 -- 2-1/8 12 16d 6 10d 2630 3535 4405 4405 4450 3265 -- 1175 5, F30, R5
PHM2316-2 WP3516-2 x 7/10 4-3/4 16 2-1/2 7 3 2 16d 2 10d -- 3745 3255 2965 3255 3255 -- -- 10, F16, R14
MPH2316-2 WM3516-2 x 12 4-5/8 16 2-1/2 7 3-3/4 2 16d duplex 2 10d -- -- -- -- -- -- 4280 -- 5, F30, R5
THO23180-2 LBV4.75/18 x 12 4-3/4 18 3 -- 2-1/8 14 16d 6 10d 2630 3535 4685 4685 4770 3520 -- 1175 5, F30, R5
PHM2318-2 WP3518-2 x 7/10 4-3/4 18 2-1/2 7 3 2 16d 2 10d -- 3745 3255 2965 3255 3255 -- -- 10, F16, R14
MPH2318-2 WM3518-2 x 12 4-5/8 18 2-1/2 7 3-3/4 2 16d duplex 2 10d -- -- -- -- -- -- 4280 -- 5, F30, R5
THO23200-2 LBV4.75/20 x 12 4-3/4 20 3 -- 2-1/8 14 16d 6 10d 2630 3535 4685 4685 4770 3520 -- 1175 5, F30, R5
PHM2320-2 WP3520-2 x 7/10 4-3/4 20 2-1/2 7 3 2 16d 2 10d -- 3745 3255 2965 3255 3255 -- -- 10, F16, R14
MPH2320-2 WM3520-2 x 12 4-5/8 20 2-1/2 7 3-3/4 2 16d duplex 2 10d -- -- -- -- -- -- 4280 -- 5, F30, R5
5 x 9-1/4 THO25925-2 LBV5.12/9.25 x 12 5-1/8 9-1/4 3 -- 2-11/16 10 16d 6 10d 2630 3535 3665 3665 3665 3080 -- 1175 5, F30, R5
THO25950-2 MIT39.5-2, LBV5.12/9.5
x 12 5-1/8 9-1/2 3 -- 2-1/8 10 16d 6 10d 2630 3535 3665 3665 3665 2710 -- 1175 5, F30, R5
PHM2595-2 WPI39.5-2 x 7/10 5-1/8 9-1/2 2-1/2 7 3 2 16d 2 10d -- 3745 3255 2965 3255 3255 -- -- 10, R14
5 x 11-1/4 THO25112-2 LBV5.12/11.25 x 12 5-1/8 11-1/4 3 -- 2-1/8 10 16d 6 10d 2630 3535 3665 3665 3665 3005 -- 1175 5, F30, R5
5 x 11-7/8 THO25118-2 LBV5.12/11.88, MIT311.88-2
x 12 5-1/8 11-7/8 3 -- 2-1/8 10 16d 6 10d 2630 3535 3665 3665 3665 3005 -- 1175 5, F30, R5
THO25140-2 MIT314-2, LBV5.12/14
x 12 5-1/8 14 3 -- 2-1/8 12 16d 6 10d 2630 3535 4405 4405 4450 3265 -- 1175 10, F16
PHM2514-2 WPI314-2 x 7/10 5-1/8 14 2-1/2 7 3 2 16d 2 10d -- 3745 3255 2965 3255 3255 -- -- 10, F16, R14
THO25160-2 MIT5.12/16, LBV5.12/16
x 12 5-1/8 16 3 -- 2-1/8 12 16d 6 10d 2630 3535 4405 4405 4450 3265 -- 1175 5, F30, R5
PHM2516-2 WPI316-2 x 7/10 5-1/8 16 2-1/2 7 3 2 16d 2 10d -- 3745 3255 2965 3255 3255 -- -- 10, F16, R14
THO25180-2 B5.12/18 x 12 5-1/8 18 3 -- 2-1/8 14 16d 6 10d 2630 3535 4685 4685 4770 3520 -- 1175 5, F30, R5
PHM2518-2 WPI318-2 x 7/10 5-1/8 18 2-1/2 7 3 2 16d 2 10d -- 3745 3255 2965 3255 3255 -- -- 10, F16, R14
THO25200-2 B5.12/20 x 12 5-1/8 20 3 -- 2-1/8 14 16d 6 10d 2630 3535 4685 4685 4770 3520 -- 1175 5, F30, R5
PHM2520-2 WPI320-2 x 7/10 5-1/8 20 2-1/2 7 3 2 16d 2 10d -- 3745 3255 2965 3255 3255 -- -- 10, F16, R14
5 x 22 PHM2522-2 WPI322-2 x 7/10 5-1/8 22 2-1/2 7 3 2 16d 2 10d -- 3745 3255 2965 3255 3255 -- -- 10, F16, R14
5 x 24 PHM2524-2 WPI324-2 x 7/10 5-1/8 24 2-1/2 7 3 2 16d 2 10d -- 3745 3255 2965 3255 3255 -- -- 10, F16, R14
1) When I-joist is used as a header, all nails must be 10d x 1-1/2.
2) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long.
3) Duplex nails are No. 8 wire gauge (0.162˝ diameter) and 3-1/2˝ long, double headed nails.
4) NA16D-RS nails are 9 gauge (0.148˝ diameter) by 3-1/2˝ long, hardened ring shank nails.
5) Masonry compressive strength shall be minimum 1500 psi for MPH hangers.
6) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted
7) Some listed loads may be increased for short-term loading. Refer to code evaluation reports for USP Structural Connectors for details.
8) Minimum nail penetration shall be 1-1/2˝ for 10d nails and 1-5/8˝ for 16d nails.
9) When I-Joists with flanges less than 1-1/2˝ thick are used as headers, the published capacity shall be reduced. Contact USP for additional information.
Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.
Web
Stif
fene
r Req
d.
Header Joist Header Material
4 - 4-3/16 x 11-7/8
4 - 4-3/16 x 14
4 - 4-3/16 x 16
4-1/2 - 4-5/8 x 9-1/2
4-1/2 - 4-5/8 x 18
4-1/2 - 4-5/8 x 20
5 x 9-1/2
4-1/2 - 4-5/8 x 11-7/8
4-1/2 - 4-5/8 x 14
4-1/2 - 4-5/8 x 16
5 x 20
5 x 14
5 x 16
5 x 18
H
L
TF
W D
USP2173-111
1-800-328-5934 • www.USPconnectors.com 133
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®EWP Top Mount Hanger Charts continued
Dimensions Fastener Schedule2,3,4,8 100% Allowable Loads (Lbs.) 1,5,7 DF-L/SP
Uplift6
Joist SizeUSP
Stock No.
Ref. No.
Ste
el G
auge
W H D L TF Qty Type Qty Type DF-
L / S
P I-
Jois
t9
LVL
PSL
LSL
DF-
L / S
P
SPF
Mas
onry
160
% CodeRef.
5 x 26 PHM2526-2 WPI326-2 x 7/10 5-1/8 26 2-1/2 7 3 2 16d 2 10d -- 3745 3255 2965 3255 3255 -- -- 10, F16, R14
PHXU55925 GLTV5.50/9.25, HB5.50/9.25, HWU5.50/9.25
x 7 5-1/2 9-1/4 3-1/4 11-1/2 3 8 16d 6 10d -- 6650 5785 6650 5285 3590 -- 1290 8, F14, R9
HLBH55925 -- -- x 7 5-9/16 9-1/4 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10565 9600 9600 8915 -- 1605 10, F16, R14 BPH5595 -- -- x 12 5-9/16 9-1/2 3 -- 2-5/32 10 16d 4 10d -- 3450 3510 3775 3450 3280 -- 815 10, R14
PHM5595 WP5.50/9.5 x 7/10 5-5/8 9-1/2 2-1/2 7 3 2 16d 2 10d -- 3745 3665 3080 3390 3390 -- -- 10, F16, R14
PHXU5595 GLTV5.59, HB5.50/9.5, HWU5.50/9.5
x 7 5-1/2 9-1/2 3-1/4 11-1/2 2-1/2 8 16d 6 10d -- 6650 5785 6650 5285 3590 -- 1290 8, F14, R9
HLBH5595 HGLTV5.59 x 7 5-9/16 9-1/2 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10565 9600 9600 8915 -- 1605 10, F16, R14 MPH5595 WM5.50/9.5 x 12 5-5/8 9-1/2 2-1/2 7 3-3/4 2 16d duplex 2 10d -- -- -- -- -- -- 4280 -- 5, F30, R5
PHXU55112 GLTV5.50/11.25, HB5.50/11.25, HWU5.50/11.25
x 7 5-1/2 11-1/4 3-1/4 11-1/2 2-1/2 8 16d 6 10d -- 6650 5785 6650 5285 3590 -- 1290 8, F14, R9
HLBH55112 -- -- x 7 5-9/16 11-1/4 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10565 9600 9600 8915 -- 1605 10, F16, R14 BPH55118 -- -- x 12 5-9/16 11-7/8 2-1/2 -- 2-1/32 10 16d 6 10d -- 3430 3510 3775 3430 3280 -- 1220 10, R14 PHM55118 -- -- x 7/10 5-5/8 11-7/8 2-1/2 7 3 2 16d 2 10d -- 3745 3665 3080 3390 3390 -- -- 10, F16, R14
PHXU55118 GLTV5.511, HB5.50/11.88, HWU5.50/11.88
x 7 5-1/2 11-7/8 3-1/4 11-1/2 2-1/2 8 16d 6 10d -- 6650 5785 6650 5285 3590 -- 1290 8, F14, R9
HLBH55118 HGLTV5.511 x 7 5-9/16 11-7/8 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10565 9600 9600 8915 -- 1605 10, F16, R14 MPH55118 WM5.50/11.88 x 12 5-5/8 11-7/8 2-1/2 7 3-3/4 2 16d duplex 2 10d -- -- -- -- -- -- 4280 -- 5, F30, R5 PHXU5512 HB5.50/12 x 7 5-1/2 12 3-1/4 11-1/2 2-1/2 8 16d 6 10d -- 6650 5785 6650 5285 3590 -- 1290 8, F14, R9 HLBH5512 -- -- x 7 5-9/16 12 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10565 9600 9600 8915 -- 1605 10, F16, R14 BPH5514 -- -- x 12 5-9/16 14 2-1/2 -- 2-1/32 10 16d 6 10d -- 3430 3510 3775 3430 3280 -- 1220 10, R14 PHM5514 -- -- x 7/10 5-5/8 14 2-1/2 7 3 2 16d 2 10d -- 3745 3665 3080 3390 3390 -- -- 10, F16, R14
PHXU5514 GLTV5.514, HB5.50/14, HWU5.50/14
x 7 5-1/2 14 3-1/4 11-1/2 2-1/2 8 16d 6 10d -- 6650 5785 6650 5285 3590 -- 1290 8, F14, R9
HLBH5514 HGLTV5.514 x 7 5-9/16 14 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10565 9600 9600 8915 -- 1605 10, F16, R14
BPH5516 LBV5.12/16 x 12 5-9/16 16 2-1/2 -- 2-1/32 10 16d 6 10d -- 3430 3510 3775 3430 3280 -- 1220 10, R14
PHM5516 -- -- x 7/10 5-5/8 16 2-1/2 7 3 2 16d 2 10d -- 3745 3665 3080 3390 3390 -- -- 10, F16, R14
PHXU5516 GLTV5.516, HB5.50/16, HWU5.50/16
x 7 5-1/2 16 3-1/4 11-1/2 2-1/2 8 16d 6 10d -- 6650 5785 6650 5285 3590 -- 1290 8, F14, R9
HLBH5516 HGLTV5.516 x 7 5-9/16 16 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10565 9600 9600 8915 -- 1605 10, F16, R14
BPH5518 -- -- x 12 5-9/16 18 2-1/2 -- 2-1/32 10 16d 6 10d -- 3430 3510 3775 3430 3280 -- 1220 10, R14 PHM5518 -- -- x 7/10 5-5/8 18 2-1/2 7 3 2 16d 2 10d -- 3745 3665 3080 3390 3390 -- -- 10, F16, R14
PHXU5518 GLTV5.518, HB5.50/18
x 7 5-1/2 18 3-1/4 11-1/2 2-1/2 8 16d 6 10d -- 6650 5785 6650 5285 3590 -- 1290 8, F14, R9
HLBH5518 HGLTV5.518 x 7 5-9/16 18 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10565 9600 9600 8915 -- 1605 10, F16, R14
PHXU5520 HB5.50/20 x 7 5-1/2 20 3-1/4 11-1/2 2-1/2 8 16d 6 10d -- 6650 5785 6650 5285 3590 -- 1290 8, F14, R9
HLBH5520 -- -- x 7 5-9/16 20 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10565 9600 9600 8915 -- 1605 10, F16, R14 7 x 7-1/4 PHXU71725 -- -- x 7 7-1/8 7-1/4 3-1/4 13-1/8 2-1/2 8 16d 6 10d -- 6650 5785 6650 5285 3590 -- 1290 130
BPH71925 -- -- x 12 7-1/8 9-1/4 3 -- 2-3/8 10 16d 6 10d -- 3485 3510 3775 3485 3280 -- 1220 PHM35925-2 -- -- x 7/10 7-1/8 9-1/4 2-1/2 10 3 2 16d 2 10d -- 3745 3665 3080 3390 3390 -- --
PHXU71925 HB7.12/9.25, WPI49.25-2
x 7 7-1/8 9-1/4 3-1/4 13-1/8 2-1/2 8 16d 6 10d -- 6650 5785 6650 5285 3590 -- 1290 8, F14, R9
HLBH71925 -- -- x 7 7-1/8 9-1/4 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10370 9600 9600 8915 -- 1605 10, F16, R14
BPH7195 B7.12/9.5 x 12 7-1/8 9-1/2 3 -- 2-3/8 10 16d 6 10d -- 3485 3510 3775 3485 3280 -- 1220
PHM3595-2 -- -- x 7/10 7-1/8 9-1/2 2-1/2 10 3 2 16d 2 10d -- 3745 3665 3080 3390 3390 -- --
PHXU7195 GLTV49.5-2, HB7.12/9.5, WPI49.5-2
x 7 7-1/8 9-1/2 3-1/4 13-1/8 2-1/2 8 16d 6 10d -- 6650 5785 6650 5285 3590 -- 1290 8, F14, R9
HLBH7195 -- -- x 7 7-1/8 9-1/2 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10370 9600 9600 8915 -- 1605 10, F16, R14 MPH3595-2 WMI49.5-2 x 12 7-1/8 9-1/2 2-1/2 8 3-3/4 2 16d duplex 2 10d -- -- -- -- -- -- 4280 -- 5, F30, R5
BPH71112 -- -- x 12 7-1/8 11-1/4 3 -- 2-3/16 10 16d 6 10d -- 3455 3515 3775 3455 3280 -- 1220 10, F16, R14
PHXU71112 GLTV411.25-2, HB7.12/11.25
x 7 7-1/8 11-1/4 3-1/4 13-1/8 2-1/2 8 16d 6 10d -- 6650 5785 6650 5285 3590 -- 1290 8, F14, R9
HLBH71112 HGLTV411.25-2 x 7 7-1/8 11-1/4 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10370 9600 9600 8915 -- 1605 10, F16, R14
MPH35112-2 WMI411.25-2 x 12 7-1/8 11-1/4 2-1/2 8 3-3/4 2 16d duplex 2 10d -- -- -- -- -- -- 4280 -- 5, F30, R5
7 x 9-1/2
10, F16, R14
7 x 11-1/4
5-1/4 x 18
5-1/4 x 20
7 x 9-1/4
10, F16, R14
5-1/4 x 11-7/8
5-1/4 x 12
5-1/4 x 14
5-1/4 x 16
Header Material
5-1/4 x 9-1/4
5-1/4 x 9-1/2
5-1/4 x 11-1/4
Web
Stif
fene
r Req
d.
Header Joist
continued on next page
1-800-328-5934 • www.USPconnectors.com134
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®EWP Top Mount Hanger Charts continued
Dimensions Fastener Schedule2,3,4,8 100% Allowable Loads (Lbs.)1,5,7 DF-L/SP
Uplift6
Joist SizeUSP
Stock No.
Ref. No.
Ste
el G
auge
W H D L TF Qty Type Qty Type DF-
L / S
P I-
Jois
t 9
LVL
PSL
LSL
DF-
L / S
P
SPF
Mas
onry
160
% CodeRef.
BPH71118 B7.12/11.88 x 12 7-1/8 11-7/8 3 -- 2-3/16 10 16d 6 10d -- 3455 3515 3775 3455 3280 -- 1220
PHM35118-2 -- -- x 7/10 7-1/8 11-7/8 2-1/2 10 3 2 16d 2 10d -- 3745 3665 3080 3390 3390 -- --
PHXU71118
GLTV411.88-2, HB7.12/11.88, HWU7.12/11.88, WPI411.88-2
x 7 7-1/8 11-7/8 3-1/4 13-1/8 2-1/2 8 16d 6 10d -- 6650 5785 6650 5285 3590 -- 1290 8, F14, R9
HLBH71118 HGLTV411.88-2 x 7 7-1/8 11-7/8 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10370 9600 9600 8915 -- 1605 10, F16, R14 MPH35118-2 WMI411.88-2 x 12 7-1/8 11-7/8 2-1/2 8 3-3/4 2 16d duplex 2 10d -- -- -- -- -- -- 4280 -- 5, F30, R5
BPH7114 B7.12/14 x 12 7-1/8 14 3 -- 2-3/16 10 16d 6 10d -- 3455 3515 3775 3455 3280 -- 1220
PHM3514-2 -- -- x 7/10 7-1/8 14 2-1/2 10 3 2 16d 2 10d -- 3745 3665 3080 3390 3390 -- --
PHXU7114 GLTV414-2, HB7.12/14, WPI414-2
x 7 7-1/8 14 3-1/4 13-1/8 2-1/2 8 16d 6 10d -- 6650 5785 6650 5285 3590 -- 1290 8, F14, R9
HLBH7114 HGLTV414-2 x 7 7-1/8 14 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10370 9600 9600 8915 -- 1605 10, F16, R14
MPH3514-2 WMI414-2 x 12 7-1/8 14 2-1/2 8 3-3/4 2 16d duplex 2 10d -- -- -- -- -- -- 4280 -- 5, F30, R5
BPH7116 B7.12/16 x 12 7-1/8 16 3 -- 2-3/16 10 16d 6 10d -- 3455 3515 3775 3455 3280 -- 1220
PHM3516-2 -- -- x 7/10 7-1/8 16 2-1/2 10 3 2 16d 2 10d -- 3745 3665 3080 3390 3390 -- --
PHXU7116 GLTV416-2, HB7.12/16, WPI416-2
x 7 7-1/8 16 3-1/4 13-1/8 2-1/2 8 16d 6 10d -- 6650 5785 6650 5285 3590 -- 1290 8, F14, R9
HLBH7116 HGLTV416-2 x 7 7-1/8 16 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10370 9600 9600 8915 -- 1605 10, F16, R14
MPH3516-2 WMI416-2 x 12 7-1/8 16 2-1/2 8 3-3/4 2 16d duplex 2 10d -- -- -- -- -- -- 4280 -- 5, F30, R5
BPH7118 B7.12/18 x 12 7-1/8 18 3 -- 2-3/16 10 16d 6 10d -- 3455 3515 3775 3455 3280 -- 1220 PHM3518-2 -- -- x 7/10 7-1/8 18 2-1/2 10 3 2 16d 2 10d -- 3745 3665 3080 3390 3390 -- --
PHXU7118 GLTV418-2, HB7.12/18, HWI418-2
x 7 7-1/8 18 3-1/4 13-1/8 2-1/2 8 16d 6 10d -- 6650 5785 6650 5285 3590 -- 1290 8, F14, R9
HLBH7118 HGLTV418-2 x 7 7-1/8 18 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10370 9600 9600 8915 -- 1605 10, F16, R14
MPH3518-2 WMI418-2 x 12 7-1/8 18 2-1/2 8 3-3/4 2 16d duplex 2 10d -- -- -- -- -- -- 4280 -- 5, F30, R5 BPH7120 B7.12/20 x 12 7-1/8 20 3 -- 2-3/16 10 16d 6 10d -- 3455 3510 3775 3455 3280 -- 1220 10, F16, R14
PHM3520-2 -- -- x 7/10 7-1/8 20 2-1/2 10 3 2 16d 2 10d -- 3745 3665 3080 3390 3390 -- -- 10, R14
PHXU7120 GLTV420-2, HB7.12/20
x 7 7-1/8 20 3-1/4 13-1/8 2-1/2 8 16d 6 10d -- 6650 5785 6650 5285 3590 -- 1290 8, F14, R9
HLBH7120 -- -- x 7 7-1/8 20 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10370 9600 9600 8915 -- 1605 10, F16, R14 BPH7122 B7.12/22 x 12 7-1/8 22 3 -- 2-3/16 10 16d 6 10d -- 3455 3510 3775 3455 3280 -- 1220 10, F16, R14
PHXU7122 HWI422-2 x 7 7-1/8 22 3-1/4 13-1/8 2-1/2 8 16d 6 10d -- 6650 5785 6650 5285 3590 -- 1290 8, F14, R9
HLBH7122 GLTV422-2, HB7.12/22, HGLTV7.12/22
x 7 7-1/8 22 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10370 9600 9600 8915 -- 1605 10, F16, R14
BPH7124 B7.12/24 x 12 7-1/8 24 3 -- 2-3/16 10 16d 6 10d -- 3455 3510 3775 3455 3280 -- 1220 10, F16, R14
PHXU7124 HWI424-2 x 7 7-1/8 24 3-1/4 13-1/8 2-1/2 8 16d 6 10d -- 6650 5785 6650 5285 3590 -- 1290 8, F14, R9
HLBH7124 GLTV424-2, HB7.12/24, HGLTV7.12/24
x 7 7-1/8 24 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10370 9600 9600 8915 -- 1605 10, F16, R14
PHXU7126 B7.12/26, HB7.12/26, HWI426-2
x 7 7-1/8 26 3-1/4 13-1/8 2-1/2 8 16d 6 10d -- 6650 5785 6650 5285 3590 -- 1290 8, F14, R9
HLBH7126 GLTV426-2, HB7.12/26
x 7 7-1/8 26 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10370 9600 9600 8915 -- 1605 10, F16, R14
PHXU7128 B7.12/28, HB7.12/28, HWI428-2
x 7 7-1/8 28 3-1/4 13-1/8 2-1/2 8 16d 6 10d -- 6650 5785 6650 5285 3590 -- 1290 8, F14, R9
HLBH7128 GLTV428-2, HB7.12/28
x 7 7-1/8 28 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10370 9600 9600 8915 -- 1605 10, F16, R14
PHXU7130 HWI430-2 x 7 7-1/8 30 3-1/4 13-1/8 2-1/2 8 16d 6 10d -- 6650 5785 6650 5285 3590 -- 1290 8, F14, R9
HLBH7130 GLTV430-2, HGLTV430-2
x 7 7-1/8 30 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10370 9600 9600 8915 -- 1605 10, F16, R14
PHXU7132 HWI432-2 x 7 7-1/8 32 3-1/4 13-1/8 2-1/2 8 16d 6 10d -- 6650 5785 6650 5285 3590 -- 1290 130
HLBH7132 GLTV432-2, HGLTV432-2
x 7 7-1/8 32 6 12 3-1/8 15 NA16D-RS 6 16d -- 10620 10370 9600 9600 8915 -- 1605 10, R14
1) When I-joist is used as a header, all nails must be 10d x 1-1/2. 2) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 3) Duplex nails are No. 8 wire gauge (0.162˝ diameter) and 3-1/2˝ long, double headed nails. 4) NA16D-RS nails are 9 gauge (0.148˝ diameter) by 3-1/2˝ long, hardened ring shank nails. 5) Masonry compressive strength shall be minimum 1500 psi for MPH hangers. 6) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted 7) Some listed loads may be increased for short-term loading. Refer to code evaluation reports for USP Structural Connectors for details. 8) Minimum nail penetration shall be 1-1/2˝ for 10d nails and 1-5/8˝ for 16d nails. 9) When I-Joists with flanges less than 1-1/2˝ thick are used as headers, the published capacity shall be reduced. Contact USP for additional information. Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.
7 x 28
7 x 30
7 x 32
7 x 20
7 x 22
7 x 24
7 x 26
7 x 16
10, F16, R14
7 x 18
10, F16, R14
7 x 11-7/8
10, F16, R14
7 x 14
10, F16, R14
Web
Stif
fene
r Req
d.
Header Joist Header Material
continued on next page
H
L
TF
W D
Floor Uplift Floor Uplift
Rafter Width Ref. No. W L Plate Rafter 100% 115% 125% 160% 100% 115% 125% 160%
1-1/2 TMP2 VPA2 18 1-9/16 5-9/16 (6) 10d (4) 10d x 1-1/2 990 990 990 220 990 990 990 220
1-3/4 TMP175 VPA25 18 1-13/16 5-9/16 (6) 10d (4) 10d x 1-1/2 1150 1150 1150 220 1150 1150 1150 220
2 or 2-1/8 TMP21 VPA2.06, VPA2.1
18 2-1/8 6-3/8 (6) 10d (4) 10d x 1-1/2 1290 1290 1290 220 1290 1290 1290 2205, F30,
R5 2-5/16 TMP23 VPA35 18 2-3/8 6-3/8 (6) 10d (4) 10d x 1-1/2 1970 1970 1970 220 1970 1970 1970 220
2-1/2 or 2-5/8 TMP25 VPA3 18 2-11/16 6-3/8 (6) 10d (4) 10d x 1-1/2 1970 1970 1970 220 1970 1970 1970 220
3 TMP31 -- -- 18 3-1/8 7-5/16 (6) 10d (4) 10d x 1-1/2 1970 1970 1970 220 1970 1970 1970 220 3-1/2 TMP4 VPA4 18 3-9/16 7-5/16 (6) 10d (4) 10d x 1-1/2 1970 1970 1970 220 1970 1970 1970 220
1) Allowable loads are governed by test results; no further increase shall be permitted. 2) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 3) Minimum nail penetration shall be 1-1/2˝ for 10d nails.
USPStock No.
SteelGauge
Roof CodeRef.
5, F10,F30, R5
5, F10,F30,R5
Allowable Loads (Lbs.) 1Dimensions Fastener Schedule2,3
Roof
DF-L / SP S-P-F
Top Side Uplift
Rafter Width Ref. No. W H D L Qty Qty Type Qty Type 6/12 7/12 8/12 9/12 10/12 11/12 12/12 13/12 14/12 160%
1-1/2 TMPH2 VPA2 1-9/16 2-1/2 4 6-9/16 8 2 10d 8 10d x 1-1/2 3190 3290 3390 3140 2900 2710 2520 2230 1950 200
1-3/4 TMPH175 VPA25 1-13/16 2-3/8 4 6-9/16 8 2 10d 8 10d x 1-1/2 3190 3290 3390 3140 2900 2710 2520 2230 1950 200
2 or 2-1/8 TMPH21 VPA2.06, VPA2.1
2-1/8 2-5/8 4 7-3/8 8 2 10d 8 10d x 1-1/2 3190 3290 3390 3140 2900 2710 2520 2230 1950 200
2-5/16 TMPH23 VPA35 2-3/8 2-1/2 4 7-3/8 8 2 10d 8 10d x 1-1/2 3190 3290 3390 3140 2900 2710 2520 2230 1950 200
2-1/2 or 2-5/8 TMPH25 VPA3 2-11/16 2-5/16 4 7-3/8 8 2 10d 8 10d x 1-1/2 3190 3290 3390 3140 2900 2710 2520 2230 1950 200
3 TMPH31 -- -- 3-1/8 2-11/16 4 8-9/16 8 2 10d 8 10d x 1-1/2 3190 3290 3390 3140 2900 2710 2520 2230 1950 200 3-1/2 TMPH4 VPA4 3-9/16 2-1/2 4 8-9/16 8 2 10d 8 10d x 1-1/2 3190 3290 3390 3140 2900 2710 2520 2230 1950 200
1) Allowable Loads may not be increased for duration of load adjustments. 2) 10d x 1-1/2 nails are 9 gauge (0.148" diameter) by 1-1/2˝ long. 3) Minimum nail penetration shall be 1-1/2˝ for 10d nails. 4) Web stiffeners are required for all Wood I-Joist installations.
10,F16,R14
CodeRef.
Allowable Loads (Lbs.)1
According to PitchUSPStock No.
Dimensions Fastener Schedule2,3
DF-L / SPPlate Rafter4
The TMP and TMPH are designed to make rafter-to-plateconnections and eliminates time-consuming bird’s-mouth notchingor bevel plate installation. Both series are available in I-Joists sizes,as well as standard 2x sizes.
TMP – Adjusts to pitches from 1/12 to 6/12.
TMPH – Adjusts to pitches from 6/12 to 14/12.
Materials: TMP – 18 gaugeTMPH – 16 gaugeFulcrum – 12 gauge
Finish: G90 galvanizingCodes: ESR-1781, ESR-1831, FL815, FL822, FL13285
L.A. CITY RR 25836, L.A. CITY RR 25843
Installation:• Use all specified fasteners. See Product Notes, page 11.• Position connector on top plate. Fasten connector tooutside of top plate with specified nails. Insert rafter into rafterpocket. Adjust rafter and pocket to correct pitch. Fasten rafterto connector with specified nails. Installing the TMP requiresdriving specified nails through the opposing slots in the pocket.TMPH installation involves sliding the fulcrum until it supportsthe pocket at the desired pitch and nailing down through the fulcrum base into the top plate to lock the fulcrum into position.
DW
H
L 4 11/16˝
fulcrum
3 1/2˝
LW
Pitch Range:TMP – 1/12 - 6/12TMPH – 6/12 - 14/12
TMPTMPH
Typical TMP installationTypical TMPH installation
Adjustable Rafter-To-Plate Connectors – TMP & TMPH series
USP2173-111
EW
PH
an
gers
1-800-328-5934 • www.USPconnectors.com 135
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
EW
PH
an
gers
Slope/Skew Hangers – LSSH series
1-800-328-5934 • www.USPconnectors.com136
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
The LSSH series connects rafters to ridge beams in vaulted roof structures. This seriesis field adjustable to meet a variety of skew and/or slope applications. Slopes to any pitchto 45° up or down and skews up to 45° right or left.
Materials: See chartFinish: G90 galvanizing; LSSH15-TZ – G185 Galvanizing
Options: LSSH15 and LSSH210 are availablein Stainless steel. To order, add SS tostock number, as in LSSH15-SS.
Codes: ESR-1781, FL816,FL13285L.A. City RR 25843
Installation:• Use all specified fasteners. See Product Notes, page 11.Steps:
1. Position LSSH connector against plumb-cut end of joist. Fasten joist side flanges on both sides with 10d x 11/2˝ nails. Bend seat up to fit against joist bottom and drive (1) 10d x 11/2˝nail through bottom seat into rafter bottom. Drive (2) 10d x 11/2˝nails at downward angle through dimpled nailing guides.2. Lean connector and rafter end against ridge beam at desired position. Install 10d or 16d nails through nail holes into ridge beam at right 90° angle. If skewing the rafter, only drive nails into ridge beam on inside flange.3. Bend flange to desired angle. 4. Hammer outside flange until edge touches header. Fasten outside flange to ridge by driving 10d or 16d nails through nail holes.• Web stiffeners are required for all wood I-Joist installations.• Designer may consider adding a tension restraint for the supported member for roof slopes exceeding 6/12.
H
W1W2 W2
3˝
Slope to 45˚up or down
LSSH210
H
Slope to45˚
up ordown
W1W2 W2
3˝
LSSH35
skew to 45° maximumskew to 45˚ maximum
12 3 & 4
Typical LSSH179installation
Floor Uplift1 Floor Uplift1
Rafter Width Ref. No. W1 W2 H Qty Type Qty Type 100% 115% 125% 160% 100% 115% 125% 160%
1-1/2 LSSH15-TZ LSU26Z 18 1-9/16 1-3/4 5-1/16 6 10d 7 10d x 1-1/2 685 785 855 740 590 675 735 625 130
1-1/2 LSSH210 LSSU210 18 1-9/16 1-3/4 8-13/16 10 10d 7 10d x 1-1/2 1140 1310 1425 1065 980 1125 1225 895 1-3/4 LSSH179 LSSUI25 18 1-13/16 1-5/8 8-13/16 10 10d 7 10d x 1-1/2 1140 1310 1425 1065 980 1125 1225 895
2 - 2-1/8 LSSH20 LSSUI2.06, LSSU2.1
18 2-1/8 2-1/2 8-13/16 10 10d 7 10d x 1-1/2 1140 1310 1425 980 980 1125 1225 825
2-1/4 - 2-5/16 LSSH23 LSSUI35 18 2-5/16 2-3/8 8-13/16 10 10d 7 10d x 1-1/2 1140 1310 1425 980 980 1125 1225 825
2-1/2 LSSH25 LSSUH310 16 2-9/16 2-3/4 8-13/16 18 16d 12 10d x 1-1/2 2485 2600 2600 1195 2140 2185 2185 1005
2-5/8 LSSH26 -- -- 16 2-11/16 2-5/8 8-13/16 18 16d 12 10d x 1-1/2 2485 2600 2600 1195 2140 2185 2185 1005 3 LSSH31 LSSU210-2 16 3-1/8 3-3/4 8-13/16 18 16d 12 10d x 1-1/2 2485 2855 3105 1585 2140 2465 2680 1330
3-1/2 LSSH35 LSSU410 16 3-9/16 3-1/2 8-13/16 18 16d 12 10d x 1-1/2 2485 2855 3105 1585 2140 2465 2680 1330
1-1/2 LSSH15-TZ LSU26Z 18 1-9/16 1-3/4 5-1/16 6 10d 7 10d x 1-1/2 685 785 815 740 590 675 685 625 130
1-1/2 LSSH210 LSSU210 18 1-9/16 1-3/4 8-13/16 10 10d 7 10d x 1-1/2 1140 1310 1425 1065 980 1125 1225 895 1-3/4 LSSH179 LSSUI25 18 1-13/16 1-5/8 8-13/16 10 10d 7 10d x 1-1/2 1140 1310 1425 1065 980 1125 1225 895
2 - 2-1/8 LSSH20 LSSUI2.06, LSSU2.1
18 2-1/8 2-1/2 8-13/16 10 10d 7 10d x 1-1/2 1140 1310 1425 980 980 1125 1225 825
2-1/4 - 2-5/16 LSSH23 LSSUI35 18 2-5/16 2-3/8 8-13/16 10 10d 7 10d x 1-1/2 1140 1310 1425 980 980 1125 1225 825
2-1/2 LSSH25 LSSUH310 16 2-9/16 2-3/4 8-13/16 14 16d 12 10d x 1-1/2 1825 1825 1825 1195 1530 1530 1530 1005 2-5/8 LSSH26 -- -- 16 2-11/16 2-5/8 8-13/16 14 16d 12 10d x 1-1/2 1825 1825 1825 1195 1530 1530 1530 1005
3 LSSH31 LSSU210-2 16 3-1/8 3-3/4 8-13/16 14 16d 12 10d x 1-1/2 1920 1920 1920 1585 1615 1615 1615 1330 3-1/2 LSSH35 LSSU410 16 3-9/16 3-1/2 8-13/16 14 16d 12 10d x 1-1/2 1920 1920 1920 1585 1615 1615 1615 1330
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 3) Minimum nail penetration shall be 1-1/2˝ for 10d nails and 1-5/8˝ for 16d nails.
CodeRef.
5,F11,F30,R5
5,F11,F30,R5
SLOPED ONLY HANGERS
SKEWED HANGERS or SLOPED & SKEWED HANGERS
USPStock No.
SteelGauge
Roof Roof
Dimensions Fastener Schedule2,3
DF-L / SP S-P-F
Allowable Loads (Lbs.)
Header Rafter
Materials: See chartFinish: USP primer
Options: See Specialty Options Chart.
Installation:• Use all specified fasteners. See Product Notes, page 11.
USP2173-111
EW
PH
an
gers
1-800-328-5934 • www.USPconnectors.com 137
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
Typical GHF51135installation
Floor Uplift3
Ref. No. W H D Qty Type Qty Type 100% 115% 125% 160%
3-1/8 x 6 GHF31600 -- -- 12 3-3/16 5-7/8 2-3/8 10 WS25 4 WS25 2190 2520 2740 1400
3-1/8 x 7-1/2 GHF31750 -- -- 12 3-3/16 7-3/8 2-3/8 12 WS25 4 WS25 2630 3020 3285 1400 3-1/8 x 9 GHF31900 -- -- 12 3-3/16 8-7/8 2-3/8 16 WS25 5 WS25 3505 4030 4380 1750
3-1/8 x 10-1/2 GHF31105 -- -- 12 3-3/16 10-3/8 2-3/8 20 WS25 6 WS25 4380 5035 5475 2100
3-1/8 x 12 GHF31120 -- -- 12 3-3/16 11-7/8 2-3/8 22 WS25 6 WS25 4820 5540 5800 2100 3-1/8 x 13-1/2 GHF31135 -- -- 12 3-3/16 13-3/8 2-3/4 24 WS25 6 WS25 5255 5665 5800 2100
3-1/8 x 15 GHF31150 -- -- 12 3-3/16 14-7/8 2-3/4 26 WS25 7 WS25 5695 6550 6730 2455 3-1/8 x 16-1/2 GHF31165 -- -- 12 3-3/16 16-3/8 2-3/4 28 WS25 9 WS25 6130 7050 7275 3155
3-1/8 x 18 GHF31178 -- -- 12 3-3/16 17-3/4 2-3/4 30 WS25 11 WS25 6570 7555 7825 3855
3-1/4 x 9 GHF32900 -- -- 12 3-5/16 8-7/8 2-3/8 16 WS25 5 WS25 3505 4030 4380 1750 3-1/4 x 12 GHF32120 -- -- 12 3-5/16 11-7/8 2-3/8 22 WS25 6 WS25 4820 5540 5800 2100
5-1/8 x 6 GHF51600 -- -- 12 5-3/16 5-7/8 2-3/8 10 WS3 4 WS3 2190 2520 2740 1400 5-1/8 x 7-1/2 GHF51750 -- -- 12 5-3/16 7-3/8 2-3/8 14 WS3 4 WS3 3065 3525 3835 1400
5-1/8 x 9 GHF51900 -- -- 12 5-3/16 8-7/8 2-3/8 18 WS3 5 WS3 3940 4535 4930 1750
5-1/8 x 10-1/2 GHF51105 -- -- 12 5-3/16 10-3/8 2-3/8 22 WS3 6 WS3 4820 5540 6025 2100 5-1/8 x 12 GHF51120 -- -- 12 5-3/16 11-7/8 2-3/8 24 WS3 6 WS3 5255 6045 6570 2100
5-1/8 x 13-1/2 GHF51135 -- -- 7 5-3/16 13-3/8 2-3/8 26 WS3 6 WS3 6500 7475 8125 2400 5-1/8 x 15 GHF51150 -- -- 7 5-3/16 14-7/8 2-3/4 28 WS3 7 WS3 7000 8050 8750 2800
5-1/8 x 16-1/2 GHF51165 -- -- 7 5-3/16 16-3/8 2-3/4 30 WS3 7 WS3 7500 8625 9375 2800
5-1/8 x 18 GHF51178 -- -- 7 5-3/16 17-3/4 2-3/4 32 WS3 8 WS3 8000 9200 10000 3200 5-1/8 x 19-1/2 GHF51192 -- -- 7 5-3/16 19-1/8 2-3/4 34 WS3 8 WS3 8500 9775 10395 3200
5-1/8 x 21 GHF51205 -- -- 7 5-3/16 20-3/8 2-3/4 36 WS3 9 WS3 9000 10350 10705 3600 5-1/8 x 22-1/2 GHF51220 -- -- 7 5-3/16 21-7/8 2-3/4 38 WS3 9 WS3 9500 10480 10705 3600
5-1/8 x 24 GHF51233 -- -- 7 5-3/16 23-1/4 2-3/4 40 WS3 11 WS3 10000 11055 11330 4400 5-1/4 x 9 GHF52900 -- -- 12 5-5/16 8-7/8 2-3/8 18 WS3 5 WS3 3940 4535 4930 1750
5-1/4 x 12 GHF52120 -- -- 12 5-5/16 11-7/8 2-3/8 24 WS3 6 WS3 5255 6045 6570 2100
6-3/4 x 6 GHF67600 -- -- 12 6-7/8 5-7/8 2-3/8 12 WS3 4 WS3 2630 3020 3285 1400 6-3/4 x 7-1/2 GHF67750 -- -- 12 6-7/8 7-3/8 2-3/8 16 WS3 5 WS3 3505 4030 4380 1750
6-3/4 x 9 GHF67900 -- -- 12 6-7/8 8-7/8 2-3/8 20 WS3 6 WS3 4380 5035 5475 2100 6-3/4 x 10-1/2 GHF67105 -- -- 12 6-7/8 10-3/8 2-3/8 24 WS3 8 WS3 5255 6045 6570 2805
6-3/4 x 12 GHF67120 -- -- 7 6-7/8 11-7/8 2-3/4 28 WS3 8 WS3 7000 8050 8750 3200
6-3/4 x 13-1/2 GHF67135 -- -- 7 6-7/8 13-3/8 2-3/4 30 WS3 8 WS3 7500 8625 9375 3200 6-3/4 x 15 GHF67150 -- -- 7 6-7/8 14-7/8 2-3/4 32 WS3 10 WS3 8000 9200 10000 4000
6-3/4 x 16-1/2 GHF67165 -- -- 7 6-7/8 16-3/8 2-3/4 34 WS3 10 WS3 8500 9775 10625 4000 6-3/4 x 18 GHF67180 -- -- 7 6-7/8 17-3/4 2-3/4 36 WS3 12 WS3 9000 10350 11250 4800
6-3/4 x 19-1/2 GHF67195 -- -- 7 6-7/8 19-1/8 3 40 WS3 14 WS3 10000 11500 12500 5600
6-3/4 x 21 GHF67210 -- -- 7 6-7/8 20-3/8 3 44 WS3 18 WS3 11000 12650 13000 7200 6-3/4 x 22-1/2 GHF67225 -- -- 7 6-7/8 21-7/8 3 46 WS3 20 WS3 11500 13000 13000 8000
6-3/4 x 24 GHF67240 -- -- 7 6-7/8 23-1/4 3 48 WS3 22 WS3 12000 13000 13000 8800
1) Allowable loads based on seat bearing calculated at 560 psi perpendicular to grain. 2) WS3 Wood Screws are 1/4" x 3˝ long and are included with hangers. 3) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. New products or updated product information are designated in bold font.
CodeRef.
130
Joist
Allowable Loads (Lbs.)1
Roof
Fastener Schedule2
DF-L / SPHeader
GlulamSize
USPStock No.
SteelGauge
Dimensions
GHF
2 1/8˝
H
DW
Option Skewed1,3 Sloped Seat2 Sloped / Skewed1,2 Inverted Flange
Range 1˚ to 50˚ 1˚ to 45˚ See Sloped Seat and Skewed Not available in widths less than 4-1/2˝
1) Skewed hangers with skews greater than 15° may have all joist nailing on outside flange. 3) All skewed GHF hangers require joist to be bevel/miter cut. 2) Sloped or sloped / skewed hangers with slopes greater than 15° may have additional joist nails.
AllowableLoads
Ordering
80% of table loadon skews greater.
75% of uplift load than 15˚.
100% of table load.65% of table load when nailing
into the support members end grain.
Add SK,angle required, and right (R)or left (L), to product number.
Ex. GHF31900-SK45R
See Sloped Seat and Skewed.Ex. GHF31900-SK45RSL30D
Add IF to product number.Ex. GHF51135IF
Add SL,slope required, and up (U) or down (D),to product number.
Ex. GHF31900-SL30D
100% of table load100% of table load.
75% of uplift load on skewsgreater than 15˚.
Specialty Options Chart – refer to Specialty Options pages 194 to 195 for additional details.
TypicalGHF51135IF
inverted flangeinstallation
Glulam Face Mount Hangers – GHF series
EW
PH
an
gers
1-800-328-5934 • www.USPconnectors.com138
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®Bolted Glulam Beam Hangers – KEG, KLEG, & KMEG series
Option Skewed 3Sloped Seat Top Flange Offset1,2
1) Top flange offset hangers may not be skewed. 3) Carried member must have square cut end on skewed option. Refer to 2) Top flange offset option is not available for KEG models. Typical PHXU hanger, skewed, left shown, Type B illustration on page 196.
Add SK,angle required,and right (R)or left (L),
to product number.Ex. KLEG3H112-SK45R
Add SL,slope required,and up (U)or down (D),
to product number.Ex. KLEG3H112-SL30D
Add OS,andright (R)or left (L),to product number.
Ex. KLEG3H112-OSL
AllowableLoads
Ordering
Range -- --
KLEG - 10000 lbs. Max.KMEG - 10000 lbs. Max.KEG - 14250 lbs. Max.
KLEG - 9665 lbs. Max.KMEG - 9665 lbs. Max.KEG - 9665 lbs. Max.
1˚ to 45˚ 1˚ to 45˚
KMEG - 5665 lbs. Max.KMEG - 11˝ min. height.
KLEG - 5665 lbs. Max.KLEG - 9˝ min. height.
Specialty Options Chart – refer to Specialty Options pages 194, 196 to 197 for additional details.
Bolt-only fastening, heavy steel construction, and acontinuous top flange allow the KLEG, KMEG, andKEG products to have high load capacities.
KLEG – (4) bolt light-duty hanger.
KMEG – (6) bolt medium-duty hanger.
KEG – (8) bolt heavy-duty hanger.
Materials: See chartFinish: USP primer
Options: See Specialty Options Chart.Codes: ESR-1280, FL11664,
L.A. City RR 25749
Installation:• Use all specified fasteners. See Product Notes,page 11.• Bolts are not supplied unless ordered separately.Bolts provided by other suppliers must meet orexceed ASTM A 307 Grade A, or ASME SAE Grade 2,or better.• Minimum header height is 9˝ for the KLEG; 9˝ for the KMEG; 11˝ for the KEG.
H
TF
4˝ 3˝
3˝
3˝ 3˝
11 1/4˝
L
D
4˝
4˝
17 1/2˝4˝
4˝4˝
4˝
H
L
TF
DW
Uplift
Floor Roof Floor Roof
Ref. No W H3D TF L Qty Dia. Qty Dia. 100% 125% 100% 125% 160%
KLEG3 LEG3 7 7 3-1/4 specify 6 2-1/2 12 4 3/4 2 3/4 11940 12200 3540 4420 3845
KLEG5 LEG5 7 7 5-1/4 specify 6 2-1/2 12 4 3/4 2 3/4 11940 12200 3540 4420 5620 KLEG7 LEG7 7 7 6-7/8 specify 6 2-1/2 12 4 3/4 2 3/4 11940 12200 3540 4420 5635
KMEG5 MEG5 7 7 5-1/4 specify 6 2-1/2 12 6 3/4 2 3/4 12635 12635 5285 6610 5620
KMEG7 MEG7 7 7 6-7/8 specify 6 2-1/2 12 6 3/4 2 3/4 12635 12635 5285 6610 5635 KEG5 EG5 3 7 5-1/4 specify 6 2-1/2 12 8 1 2 1 17615 19920 9215 11520 7305
KEG7 EG7 3 7 6-7/8 specify 6 2-1/2 13-1/2 8 1 2 1 18695 21005 9245 11555 9215
KEG9 EG9 3 7 8-7/8 specify 6 2-1/2 15-1/2 8 1 2 1 20125 21220 9275 11595 9240 KEG11 -- -- 3 7 10-7/8 specify 6 2-1/2 17-1/2 8 1 2 1 21545 23870 9295 11620 9260
1) Allowable loads are for a supporting member with a width of 5-1/2", and 560 psi perpendicular to grain loading in single shear. 2) Uplift loads have been increased 60% for wind and seismic loads; no further increase shall be permitted. 3) "Specify" denotes the required supported beam height that must be specified at the time of ordering.
USPStock No.
Without Top Flange1
FC ⊥ = 560 psi
Allowable Loads (Lbs.)
With Top Flange1
CodeRef.
2,F20,R12
DimensionsSteel Ga.
Top
Flan
ge
Bolt Schedule
Header Joist
U-S
trap
KMEG5
4˝
3˝8 1/4˝
3˝
3˝
H
LTF
DW
KLEG3Typical KLEG5
installation
KEG5
Beam height dimension (H) mustbe specified when ordering.
USP2173-111
EW
PH
an
gers
1-800-328-5934 • www.USPconnectors.com 139
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
These hangers cover medium-to-heavy glulam beam andpurlin applications.
KHHB – Medium-duty hanger.
KGB – Medium to heavy-duty hanger.
KHGB – Heavy-duty hanger.
Materials: 7 gaugeFinish: USP primerCodes: ESR-1280, FL11664, L.A. City RR 25749
Installation:• Use all specified fasteners. See Product Notes, page 11.• Minimum height (H) is 71/2˝.
Typical KHHB installation
Uplift1
Top Face Floor Floor
Ref. No. W H D Qty Qty Type Qty Type 100% 115% 125% 100% 115% 125% 160%
KHHB3 HHB3 3-1/4 specify 3 4 6 WS3 6 WS3 4885 5115 5265 5275 5505 5655 2440 2, F20, R12
KGB3 GB3 3-1/4 specify 3-1/2 4 10 WS3 6 WS3 6460 6840 7095 6915 7295 7550 2440 130 KHHB5 HHB5 5-1/4 specify 3 4 6 WS3 6 WS3 4885 5115 5265 5275 5505 5655 2440 2, F20, R12
KGB5 GB5 5-1/4 specify 3-1/2 4 10 WS3 6 WS3 6460 6840 7095 6915 7295 7550 2440 130
KHGB5 HGB5 5-1/4 specify 4 4 12 WS3 6 WS3 7530 7985 8290 8050 8505 8810 2440 130 KHHB7 HHB7 6-7/8 specify 3 4 6 WS3 6 WS3 4885 5115 5265 5275 5505 5655 2440 2, F20, R12
KGB7 GB7 6-7/8 specify 3-1/2 4 10 WS3 6 WS3 6460 6840 7095 6915 7295 7550 2440 130 KHGB7 HGB7 6-7/8 specify 4 4 12 WS3 6 WS3 7530 7985 8290 8050 8505 8810 2440 130
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) "Specify" denotes the required supported beam height must be specified at the time of ordering. 3) Supporting header shall be no less than 3˝ thick. 4) WS3 Wood Screws are 1/4" x 3˝ long and are included with hangers. New products or updated product information are designated in bold font.
3-1/8
5-1/8
6-3/4
Fastener Schedule4
Header3
Joist
CodeRef.
Allowable Loads (Lbs.)
RoofBeamWidth
USPStock No.
Dimensions 2
FC ⊥ = 560 psi FC⊥ = 625 psi
Roof
KHHBW
D
H
2 1/2˝
See Welded Installation chart on page 198
Glulam Hangers – KGB, KHGB, & KHHB series
Beam height dimension (H) mustbe specified when ordering.
Uplift
Floor Roof Floor Roof
Ref. No W
KLEG3 LEG3 7 7 3-1/4 specify 6 2-1/2 12 4 3/4 2 3/4 11940 12200 3540 4420 3845
KLEG5 LEG5 7 7 5-1/4 specify 6 2-1/2 12 4 3/4 2 3/4 11940 12200 3540 4420 5620 KLEG7 LEG7 7 7 6-7/8 specify 6 2-1/2 12 4 3/4 2 3/4 11940 12200 3540 4420 5635
KMEG5 MEG5 7 7 5-1/4 specify 6 2-1/2 12 6 3/4 2 3/4 12635 12635 5285 6610 5620
KMEG7 MEG7 7 7 6-7/8 specify 6 2-1/2 12 6 3/4 2 3/4 12635 12635 5285 6610 5635 KEG5 EG5 3 7 5-1/4 specify 6 2-1/2 12 8 1 2 1 17615 19920 9215 11520 7305
KEG7 EG7 3 7 6-7/8 specify 6 2-1/2 13-1/2 8 1 2 1 18695 21005 9245 11555 9215
KEG9 EG9 3 7 8-7/8 specify 6 2-1/2 15-1/2 8 1 2 1 20125 21220 9275 11595 9240 KEG11 -- -- 3 7 10-7/8 specify 6 2-1/2 17-1/2 8 1 2 1 21545 23870 9295 11620 9260
Top
Flan
ge
U-S
trap
EW
PH
an
gers
1-800-328-5934 • www.USPconnectors.com140
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
These heavy beam hangers are designed for use with glulamand timber beams. The continuous top mount flange offers highload capacity with minimal nailing.
KGLT – Medium-duty hanger.
KHGLT – Heavy-duty hanger.
Materials: See chartFinish: USP primer
Options: See Specialty Options Chart.Codes: ESR-1280, L.A. City RR 25749,
FL11664
Installation:• Use all specified fasteners. See Product Notes, page 11.
L
H
6˝
2 1/2˝
6 3/4˝
W
Glulam Beam Hangers – KGLT & KHGLT series
Option Skewed1,3 Sloped Seat2,3 Sloped / Skewed1,2,3 Sloped Top Flange4 Top Flange Offset Saddle
Range 1˚ to 50˚ 1˚ to 45˚ See Sloped Seat and Skewed 0˚ to 45˚ -- -- -- --
1) Skewed hangers with skews greater than 15° may have all joist nailing on outside flange. 2) Sloped or sloped / skewed hangers with slopes greater than 15° may have additional joist nails. 3) All sloped, skewed, or combinations require bevel cut on joist in all applications. 4) Sloped top flanges with slopes greater than 15° may have additional header nails.
Add SA, and saddlewidth required
to product number.Ex. KGLT3H16-SA=5-1/2˝
KGLT - 4110 lbs. Max.KHGLT - 7000 lbs. Max.
Add SL,slope required,and up (U)or down (D),
to product number.Ex. KGLT3H16-SL30D
See Sloped Seat and Skewed.Ex. KGLT3H16-SK45RSL30D
Add SF,angle requiredand right (R)or left (L),
to product number.Ex. KGLT3H16-SF30L
Add OS,andright (R)or left (L),
to product number.Ex. KGLT3H16-OSL
50% of uplift load onskew greater than 15˚
Table Loads usingReduce Allowable
straight-line interpolation
60% of table loadfor KGLT.
45% of table loadfor KHGLT.
100% of table loadper side
AllowableLoads
Ordering
50% of uplift load onskew greater than 15˚
Add SK,angle required,and right (R)or left (L),
to product number.Ex. KGLT3H16-SK45R
Specialty Options Chart – refer to Specialty Options pages 194, 196 to 197 for additional details.
Uplift
Top Face Floor Floor
Ref. No. U-Strap W H L Qty Qty Type Qty Type 100%3115% 125% 100%3
115% 125% 160%
3-1/8 KGLT3 GLT3 3 7 3-1/4 specify 10 4 6 WS3 8 WS3 7545 7815 7995 --- --- --- 2870
3-1/2 KGLT4 GLT4 3 7 3-5/8 specify 10 4 6 WS3 8 WS3 7545 7815 7995 --- --- --- 2870
5-1/8 KGLT5 GLT5 3 7 5-1/4 specify 10 4 6 WS3 8 WS3 7545 7815 7995 --- --- --- 2870 5-1/2 KGLT6 GLT6 3 7 5-5/8 specify 10 4 6 WS3 8 WS3 7545 7815 7995 --- --- --- 2870
6-3/4 KGLT7 GLT7 3 7 6-7/8 specify 12 4 6 WS3 8 WS3 7545 7815 7995 --- --- --- 2870 8-3/4 KGLT9 -- -- 3 7 8-7/8 specify 14 4 6 WS3 8 WS3 7545 7815 7995 --- --- --- 2870
3-1/8 KHGLT3 HGLT3 3 7 3-1/4 specify 12 6 12 WS3 6 WS3 10150 10380 10530 12965 13400 13400 2440
3-1/2 KHGLT4 HGLT4 3 7 3-5/8 specify 12 6 12 WS3 6 WS3 10490 11025 11385 12965 13400 13400 2440 5-1/8 KHGLT5 HGLT5 3 7 5-1/4 specify 12 6 12 WS3 6 WS3 10490 11025 11385 12965 13400 13400 2440
5-1/2 KHGLT6 HGLT5 3 7 5-5/8 specify 12 6 12 WS3 6 WS3 10490 11025 11385 12965 13400 13400 2440 6-3/4 KHGLT7 HGLT7 3 7 6-7/8 specify 12 6 12 WS3 6 WS3 10490 11025 11385 12965 13400 13400 2440
8-3/4 KHGLT9 HGLT9 3 7 8-7/8 specify 14 6 12 WS3 6 WS3 11640 12175 12535 13400 13400 13400 2440 10-3/4 KHGLT11 -- -- 3 7 10-7/8 specify 16 6 12 WS3 6 WS3 12790 13325 13400 13400 13400 13400 2440
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) KGLT load values based on 460 psi perpendicular to grain loading. KHGLT load values based on 460 psi or 625 psi perpendicular to grain loading. 3) No further increase for duration of load allowed. 4) "Specify" denotes the required supported beam height that must be specified at time of ordering, with 7-1/2 ̋being the minimum. 5) WS3 Wood Screws are 1/4" x 3˝ long and are included with hangers. New products or updated product information are designated in bold font.
Allowable Loads (Lbs.) 2Dimensions 4 Fastener Schedule5
BeamWidth
USPStock No.
TopFlange
Steel Gauge
2,F20,R12
Roof
Header Joist
CodeRef.
FC ⊥ = 460 psi FC⊥ = 625 psi
Roof
Typical KGLT5 installation
L
H
5˝
2 1/2˝3 1/2˝
W
KGLTKHGLT See Welded Installation chart on page 198
Beam height dimension (H) mustbe specified when ordering.
USP2173-111
EW
PH
an
gers
1-800-328-5934 • www.USPconnectors.com 141
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
KHC3side view
KHC3top view
3˝
PT
PD
W
H
KHC3
Hinge Connectors & Seismic Straps – KHC & KHCST series
Allowable Loads (Lbs.)1
DF-L / SP
F1
Ref. No. Qty Dia. Qty Dia. 160%
* KHC HCA 8 2 3/4 -- -- -- -- -- --
* KHC2T -- -- 9 2 3/4 2 3/4 -- -- KHC2CT HC2CTA 12 2 3/4 2 3/4 9445
KHCCT HCCTA 12 2 3/4 3 3/4 14170
KHC4CT HC4CTA 12 2 3/4 4 3/4 18895 * KHC3 HC3A 8 3 3/4 -- -- -- -- -- --
* KHC3T -- -- 9 3 3/4 3 3/4 -- -- KHC2C3T -- -- 12 3 3/4 2 3/4 9445
KHCC3T HCC3TA 12 3 3/4 3 3/4 14170
KHC4C3T HC4C3TA 12 3 3/4 4 3/4 18895
1) Loads are based on a 5-1/8˝ width Douglas-Fir Larch beam. 2) All bolts are 3/4˝, and shall meet or exceed the specifications of ASTM A 307. 3) Minimum H may be less than H required for listed loads; in which case, load reductions are required. * When used with optional KHCST Seismic Strap, the minimum H is 12˝.
USPStock No.
Prefix
Min.H3
Rotation Bolts2
/Beam
Seismic Bolts2
KHC – Supports a glulam beam off of another glulam beam. Refer to theOptional Horizontal Loading Chart for design variations.
KHCST – Seismic straps can be installed during construction or added asa retrofit item.
Materials: See chartFinish: USP primerCodes: ESR-1280, L.A. City RR 25749,
FL11664
Installation:• Use all specified fasteners. See Product Notes, page 11.• To allow for wood shrinkage, position bolts in slots away from the bearing seat.• For dapped beams, reduce the “H” dimension by the “PT”dimension for each dap.
Ref. No. W PD PT H2410 psi 560 psi H2
410 psi 560 psi
55 HCA5-5 7 5-1/4 5 3/4 17-1/2 10505 14350 14 10505 14350
56 HCA5-6 7 5-1/4 6 3/4 22-3/4 12610 17220 17-1/2 12610 17220
57 HCA5-7 7 5-1/4 7 3/4 28-3/4 14710 20090 21-3/4 14710 2009059 HCA5-9 7 5-1/4 9 3/4 43-1/2 18910 25830 32 18910 25830
75 HCA7-5 7 6-7/8 5 1 20-3/4 13840 18900 16 13840 1890076 HCA7-6 7 6-7/8 6 1 27-1/2 16605 22680 20-3/4 16605 22680
77 HCA7-7 7 6-7/8 7 1 35-1/2 19375 26460 26-1/4 19375 26460
79 HCA7-9 7 6-7/8 9 1 55 24910 34020 40 24910 3402095 HCA9-5 7 8-7/8 5 1-1/4 24-3/4 17940 24500 18-3/4 17940 24500
96 HCA9-6 7 8-7/8 6 1-1/4 33-1/2 21525 29400 24-3/4 21525 2940097 HCA9-7 7 8-7/8 7 1-1/4 43-3/4 25115 34300 32 25115 34300
99 HCA9-9 7 8-7/8 9 1-1/4 69-1/4 32290 44100 49-3/4 32290 44100
115 HCA11-5 3 10-7/8 5 1-1/2 27-1/4 22040 30100 20-1/4 22040 30100116 HCA11-6 3 10-7/8 6 1-1/2 37-1/4 26445 36120 27 26445 36120
117 HCA11-7 3 10-7/8 7 1-1/2 49-1/4 30855 42140 35-1/4 30855 42140119 HCA11-9 3 10-7/8 9 1-1/2 78-1/4 39670 54180 55-1/4 39670 54180
1) Allowable loads shall not be further increased for duration. 2) The minimum height is for loads shown. For heights less than the minimum shown reduce the allowable loads in direct proportion. 3) All bolts are 3/4˝, and shall meet or exceed the specifications of ASTM A 307.
CodeRef.
2,F20,R12
5-1/8
6-3/4
8-3/4
10-3/4
DF-L / SP DF-L / SPBeamWidth
SteelGauge
USPStock No.
Suffix
Dimensions (2) Rotation Bolts3 Per Beam (3) Rotation Bolts3 Per Beam
Allowable Loads (Lbs.)1
Allowable Loads (Lbs.)1
F1 KHCST strap
continued on next page
Typical KHCinstallation
KHC Optional Horizontal Loading Chart
EW
PH
an
gers
1-800-328-5934 • www.USPconnectors.com142
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
KHCCT
Allowable Loads (Lbs.)1,2
DF-L / SP
Ref. No. W L Qty Dia. F1 (160%)
KHCST2 HCST2 KHCSTR2 HCSTR2
KHCST3 HCST3 KHCSTR3 HCSTR3
KHCST4 HCST4
KHCSTR4 HCSTR4
1) Allowable loads are for straps used in pairs, and are increased 60% for wind or seismic loads; no further increase shall be permitted. 2) Loads are based on a 5-1/8˝ width Douglas-Fir-Larch beam. 3) Seismic straps shall be used with the KHC hinge connectors.
3/4
9950
14500
20145
Dimensions Bolt Schedule
7
7
3-1/2
3-1/2
25-5/8
31-5/8
4 3/4
CodeRef.
USP
Stock No.3Steel
Gauge
3 3-1/2 37-5/8
6 3/4
8
2, F20,R12
Rotation tabs
Seismic tabs
KHC4CT KHC4C3T
KHC3TKHC2TKHC2C3T
KHCC3T KHC
KHC2CT
KHC3
Seismic Straps - KHCST series
WL
KHCST
Hinge Connectors & Seismic Straps – KHC & KHCST series cont.
USP2173-111
EW
PH
an
gers
1-800-328-5934 • www.USPconnectors.com 143
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®Glulam Saddle Hangers – KGLS, KGLST, KHGLS, & KHGLST series
KGLS – Saddle hanger.KGLST – Saddle hanger with seismic straps.KHGLS – Heavier version of KGLS.KHGLST – Heavier version of KGLST.
Materials: Top flange - 3 gauge; Stirrup - 7 gaugeFinish: USP primer
Options: See KGLS & KHGLS Specialty Options Chart.Codes: ESR-1280, L.A. City RR 25749, FL11664
Installation:• Use all specified fasteners. See Product Notes, page 11. • Loads and nail schedule apply to each saddle hanger stirrup.• Minimum header height is 81⁄2˝ for the KGLS; 81⁄2˝ for the KGLST;101⁄2˝ for the KHGLS, and 101⁄2˝ for the KHGLST.• KGLST and KHGLST models include seismic straps which must be installed with (3) 3⁄4˝thru-bolts in each supported member and (2)3⁄4˝ thru-bolts into the supporting beams.
Uplift Tension
Floor
Ref. No. W H4D L TF Qty Type Qty Dia. Qty Type Qty Dia. 100% 115% 125% 160% 160%
KGLS35 GLS3-5 3-1/4 specify 5 6 5-1/4 6 WS3 -- -- -- -- 6 WS3 -- -- -- -- 10275 10505 10655 2440 -- --
KGLST35 GLST3-5 3-1/4 specify 6-1/2 10 5-1/4 6 WS3 2 3/4 6 WS3 3 3/4 12900 13130 13280 2440 15120 KGLS37 GLS3-7 3-1/4 specify 5 6 6-7/8 6 WS3 -- -- -- -- 6 WS3 -- -- -- -- 10275 10505 10655 2440 -- --
KGLST37 GLST3-7 3-1/4 specify 6-1/2 10 6-7/8 6 WS3 2 3/4 6 WS3 3 3/4 12900 13130 13280 2440 15120
KGLS39 GLS3-9 3-1/4 specify 5 6 8-7/8 6 WS3 -- -- -- -- 6 WS3 -- -- -- -- 10275 10505 10655 2440 -- -- KGLST39 GLST3-9 3-1/4 specify 6-1/2 10 8-7/8 6 WS3 2 3/4 6 WS3 3 3/4 12900 13130 13280 2440 15120
KGLS55 GLS5-5 5-1/4 specify 5 9 5-1/4 6 WS3 -- -- -- -- 6 WS3 -- -- -- -- 14710 14980 15160 2440 -- -- KGLST55 GLST5-5 5-1/4 specify 6-1/2 12 5-1/4 6 WS3 2 3/4 6 WS3 3 3/4 19015 19285 19465 2440 15120
KGLS57 GLS5-7 5-1/4 specify 5 9 6-7/8 6 WS3 -- -- -- -- 6 WS3 -- -- -- -- 15875 16105 16255 2440 -- --
KGLST57 GLST5-7 5-1/4 specify 6-1/2 12 6-7/8 6 WS3 2 3/4 6 WS3 3 3/4 20180 20410 20560 2440 15120 KHGLS5 HGLS5 5-1/4 specify 6-1/2 12 specify 14 WS3 -- -- -- -- 8 WS3 -- -- -- -- 20685 20990 21195 3250 -- --
KHGLST5 HGLST5 5-1/4 specify 6 12 specify 14 WS3 2 3/4 8 WS3 3 3/4 19250 19555 19760 3250 15120 KGLS77 GLS7-7 6-7/8 specify 5 12 6-7/8 6 WS3 -- -- -- -- 6 WS3 -- -- -- -- 20425 20655 20805 2440 -- --
KGLST77 GLST7-7 6-7/8 specify 6-1/2 12 6-7/8 6 WS3 2 3/4 6 WS3 3 3/4 24475 24745 24925 2440 15120
KGLS79 GLS7-9 6-7/8 specify 5 12 8-7/8 6 WS3 -- -- -- -- 6 WS3 -- -- -- -- 20425 20655 20805 2440 -- -- KGLST79 GLST7-9 6-7/8 specify 6-1/2 12 8-7/8 6 WS3 2 3/4 6 WS3 3 3/4 26095 26325 26475 2440 15120
KHGLS7 HGLS7 6-7/8 specify 6 12 specify 14 WS3 -- -- -- -- 8 WS3 -- -- -- -- 20985 21615 22035 3250 -- -- KHGLST7 HGLST7 6-7/8 specify 6-1/2 14 specify 14 WS3 2 3/4 8 WS3 3 3/4 23785 24415 24835 3250 15120
KHGLS9 HGLS9 8-7/8 specify 6 12 specify 14 WS3 -- -- -- -- 8 WS3 -- -- -- -- 20985 21615 22035 3250 -- --
KHGLST9 HGLST9 8-7/8 specify 6-1/2 16 specify 14 WS3 2 3/4 8 WS3 3 3/4 26585 27215 27635 3250 15120
1) Allowable loads and fastener schedules apply to each side of the saddled hanger. 4) Hangers with seismic straps may require a minimum joist depth. 2) WS3 Wood Screws are 1/4" x 3˝ long and are included with hangers. Consult USP for additional information. 3) Minimum header height is 8-1/2˝ for the KGLS and KGLST; 10-1/2˝ for the KHGLS and KHGLST.
New products or updated product information are designated in bold font.
Allowable Loads (Lbs.)1
Roof
FC⊥ = 560 psi
2,F20,R12
CodeRef.
Fastener Schedule
Nails1, Bolts
Header
8-3/4
Joist
3-1/8
5-1/8
6-3/4
Nails1,2 BoltsSupported
GlulamBeam Size
USPStock No.
Dimensions 4
Option Skewed 1 Sloped Seat2 Sloped / Skewed1,2 Sloped Top Flange3Top Flange Offset Saddle
Range 1˚ to 50˚ 1˚ to 45˚ See Sloped Seat and Skewed 0° to 30° May not be skewed 5˝ minimum saddle
1) Skewed hangers with skews greater than 15° may have all joist nailing on outside flange. 2) Sloped or sloped / skewed hangers with slopes greater than 15° may have additional joist nails. 3) Sloped top flanges with greater than 15° may have additional header nails.
100% of table loadper side
Add OS, andright (R) or left (L),to product number.
Ex. KGLS35H115-OSL
Add SA, andsaddle width requiredto product number.
Ex. KGLS35H115-SA=5-1/2˝
AllowableLoads
Ordering
KGLS - 6500 lbs. Max.KHGLS - 7980 lbs. Max.
50% of uplift loadon skews greater than 15°.
Add SK,angle required,and right (R)or left (L),
to product number.Ex. KGLS35H115-SK45R
KGLS - 6500 lbs. Max.KHGLS - 9165 lbs. Max.
KGLS - 5500 lbs. Max.KHGLS - may not
be sloped / skewed.
Reduce allowabletable loads using
straight-line interpolation.
50% of table loadfor KGLS.
45% of table loadfor KHGLS.
Add SL,slope required,and up (U)or down (D),
to product number.Ex. KGLS35H115-SL30D
Add SF, angle required,and right (R) or left (L),
to product number.Ex. KGLS35H115-SF30L
See Sloped Seat and Skewed.Ex. KGLS35H115-SK45RSL30D
KGLS & KHGLS Specialty Options Chart – refer to Specialty Options pages 194, 196 to 197 for additional details.
KHGLST
TF L
DW
H
KGLS
See Welded Installation chart on page 198
Typical KHGLST35installation
H
D
TF L
W
Beam height dimension (H) mustbe specified when ordering.
Tru
ss &
Raft
er
1-800-328-5934 • www.USPconnectors.com144
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
SHA
Moisture Barrier Plates . . . . . . .Page 145• NOP SeriesProtects bottom chord of trusses from moisture damage.
Embedded Truss Anchors .Pages145-149• LPTA & HLPTA75Low profile truss anchors provide uplift and lateral load resistance.
• HTA SeriesStrap truss anchor provides uplift and lateral load resistance.
• DTCStrap truss anchor provides uplift and higher lateral load resistance.
Uplift Girder Ties . . . . . . .Pages 149-151• RUSCRetrofit Strap Connector provides a wood-to-wood upliftconnection with WS Wood Screws.
• USC SeriesWraparound truss anchor mechanically fastens into the face of masonry or concrete.
• RFUSRetrofit truss anchor installed mechanically fastens into the face ofmasonry or concrete.
Girder Tiedowns . . . . . . . . .Pages 151-153• LUGT SeriesLight capacity girder truss anchor nails to the truss/rafter and the stud.Can also be used for masonry applications.
• MUGT15Medium capacity girder truss anchor wraps over the top chord andbolts to the concrete or tension tie.
• HUGT SeriesHeavy capacity girder truss anchor installs over the top chord and boltsto the concrete or tension tie.
Masonry Uplift Connectors . . .Page 153• SHA SeriesHeavy capacity uplift connector bolts both to the truss and masonry.
Hurricane Gusset Angles . . . . . .Page 154• HGA SeriesConnects gable trusses to top plates.
HurricaneRetro-Fit Connector . . . . . . . . . . . . . Pages 154 -155• RT16M Retro-fit connector for trusses installed on top plates.
Hurricane/Seismic Anchors . . . . . . . . . . . . . . .Pages 155-157• HC520, HCPRS, HHCP2, & RT SeriesTop plate to truss anchors.
NOP
LPTA HLPTA75
HTA
RT15
RT16M
RT7 HCPRS
USC RFUS
LUGT MUGT15 HUGT
HGA
HHCP2
RUSC
Truss & Rafter Tiedowns
DTC
Embedded Truss Anchors – LPTA series
Low profile design attaches to 2 x 4 or larger bottom chords andprovides uplift and lateral load resistance.
Materials: 18 gaugeFinish: G90 galvanizingCodes: 2031C, FL859
Installation:• Use all specified fasteners. See Product Notes, page 11.• Embed LPTA 4˝ into concrete tie beam or masonry bondbeam.• Anchors should be spaced no closer than 8˝ center-to-center.• Moisture barrier may be required.
USP2173-111
Tru
ss &
Rafte
r
1-800-328-5934 • www.USPconnectors.com 145
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
Typical NOP4installation
Embedded Truss Anchorspages 145-149
NOP4
Moisture Barrier Plates – NOP series
F1 F2
Ref. No. W H Type DF-L / SP S-P-F 160% 160%
LPTA LTA1 18 5 8-1/4 10 10d x 1-1/2 1250 1250 810 1500 L1, F17
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 3) Minimum quantity of fasteners to be installed. Product may have additional nail holes not needed to meet published allowable load of product.
USPStock No.
Fastener Schedule2
Min
Qty.3
Dimensions
CodeRef.
Allowable Loads (Lbs.)
SteelGauge
Uplift (160%)1
W
1 7/16˝ 1 3/4˝
H
LPTA
Typical LPTAinstallation
LW
NOP1
Moisture Barrier Plates protect the bottom chordsof trusses from moisture damage caused by directcontact with concrete. These plates eliminate theneed for more expensive treated wood plates.
Materials: See chartFinish: G90 galvanizing
Installation:• Use all specified fasteners. See Product Notes,page 11.• Pre-attach to truss bottom chord or rafter usingprepunched prongs and/or 6d common nails toprevent wood-to-concrete contact.
LW
NOP4
Size Ref. No. W L Qty Type
2x NOP2X TSS2-2 26 1-7/16 8 -- -- -- -- 2x NOP1 TSS2 22 1-1/2 8 2 6d
4x NOP4 TSS4 26 3-1/2 8 2 6d
CodeRef.
120
USPStock No.
SteelGauge
Dimensions Fastener Schedule
LW
NOP2X
Tru
ss &
Raft
er
1-800-328-5934 • www.USPconnectors.com146
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
F2 F1
Uplift
Trussmember
The HLPTA75 is designed and tested to provide higher lateral capacity andnet uplift. Offers greater pullout resistance and is compatible with bond beamreinforcing.
Materials: 18 gaugeFinish: G90 galvanizingCodes: Dade County, FL 08-0715.01, FL1247Patent: #7,254,919
Installation:• Use all specified fasteners. See Product Notes, page 11.• Embed in concrete tie beam or masonry bond beam until the seat is restingon the surface.• Minimum of one #7 rebar or two #5 rebars through the theoretical shearcone is required.• Grout or concrete compressive strength shall be 2,000 psi at 28 days.• Minimum spacing between anchors is 10˝ to achieve full design load capacities on single anchors.• When used in a double rebar installation, concrete tie beam stirrup shouldbe sized to accommodate connector leg placement.• Designer shall verify connector clearance when using in conjunction withstirrups and two rebar applications.• Verify grout is not in contact with truss member. Moisture barrier may berequired.
Ref. No. Qty Type Qty Type F1 F2 Uplift F1 F2 Uplift
Single Anchor 2 10d x 1-1/2 20 10d x 1-1/2 1860 1715 2125 1860 1160 2125 F22, D13
Double Anchor -- -- -- -- 40 10d x 1-1/2 2040 2100 3500 2040 2100 3500 130
1) Allowable loads have been increased 60% for wind and seismic loads; no further increase shall be permitted. 2) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long.
CodeRef.
Fastener Schedule2 Allowable Loads (Lbs.)1
DF-L / SP (160%) S-P-F (160%)Seat Plate Truss/RafterInstallationType
HLPTA75
USPStock No.
SteelGauge
-- -- 18
13/16˝
13/16˝
1 3/16˝
4 13/16˝
4 15/16˝
9 9/16˝
HLPTA75
Typical HLPTA75 double rebar installation
Typical HLPTA75 single rebar installation
Concrete tie wall
Masonry wall
Tie beamreinforcing
F2 F1
Uplift
Trussmember
Typical HLPTA75single anchor installation
Typical HLPTA75double anchor installation
Embedded Truss Anchor – HLPTA75
HTA – Offers a higher capacity alternative to the TA model with two rows ofnails.
TA – Anchors are rated for both uplift and lateral loads. They can be installedstraight or field-bent around truss or rafter members. An embossed embedment line assures accurate embedment depth.
TAR – Riveted anchors provide a moisture barrier in addition to uplift and lateral resistance all in one product.
Materials: HTA-18 – 18 gauge; HTA – 16 gauge; TA & TAR – 14 gaugeFinish: G90 galvanizing
Options: HTA20 and HTA24 are available in Triple Zinc. To order, add TZ to stock number, as in HTA20-TZ.
Codes: NER 608, 2031C, FL859
Installation:• Use all specified fasteners. See Product Notes, page 11.• Embed 4˝ into concrete tie beam or masonry bond beam.• For double anchor installations: anchors should be installed on opposite sides of wood member and centered in masonry bond beam.• Designer may specify alternative nailing schedules. Refer to Nail Specificationtable on page 15 for nail shear values, load values shall not exceed publishedallowable loads.• When using alternative nailing schedules, lower-most holes in strap shall befilled progressing upward towards the top of the strap.• Moisture barrier may be required for HTA installations.
USP2173-111
Tru
ss &
Rafte
r
1-800-328-5934 • www.USPconnectors.com 147
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
4˝ Embedment
1 1/2˝
W
H
HTA24-18
F2
F1
Typical HTA24-18installation
Embedded Truss Anchors – HTA, TA, & TAR series
F1
F2
Uplift
Typical TA18 installation
4˝ Embedment
1 1/2˝
1˝ Typ.
W
H
TA24
continued on next page
Tru
ss &
Raft
er
Embedded Truss Anchors – HTA, TA, & TAR series cont.
1-800-328-5934 • www.USPconnectors.com148
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®DF-L / SP S-P-F F1 F2 F1 F2
1 Ply 1 Ply 1 Ply 2 Ply or > 1 Ply 2 Ply or >
Ref. No. W H Type 160% 160% 160% 160% Type 160% 160% 160% 160% 160% 160%
HTA16-18 META12, META14, META16
1-1/4 12 10 10d x 1-1/2 1400 1400 395 325 10 10d x 1-1/2 2800 2800 2800 2800 790 650
HTA20-18 META18, META20
1-1/4 16 10 10d x 1-1/2 1400 1400 395 325 10 10d x 1-1/2 2800 2800 2800 2800 790 650
HTA24-18 META22, META24
1-1/4 20 10 10d x 1-1/2 1400 1400 395 325 10 10d x 1-1/2 2800 2800 2800 2800 790 650
HTA12 HETA12 1-1/4 8 8 10d x 1-1/2 1600 1265 590 660 8 10d x 1-1/2 3200 3200 2530 2530 1180 1320
HTA16 HETA16 1-1/4 12 10 10d x 1-1/2 1615 1585 590 660 10 10d x 1-1/2 3230 3230 3170 3170 1180 1320
HTA20 HETA20 1-1/4 16 10 10d x 1-1/2 1615 1585 590 660 10 10d x 1-1/2 3230 3230 3170 3170 1180 1320 HTA24 HETA24 1-1/4 20 10 10d x 1-1/2 1615 1585 590 660 10 10d x 1-1/2 3230 3230 3170 3170 1180 1320
HTA48 HETA40, META40
1-1/4 42-1/2 10 10d x 1-1/2 1615 1585 590 660 10 10d x 1-1/2 3230 3230 3170 3170 1180 1320 130
TA12 -- -- 1 6-3/4 5 10d x 1-1/2 990 790 245 335 5 10d x 1-1/2 1980 1980 1580 1580 490 670 TA14 -- --
TA14R META12/TSS2, META14/TSS2
TA16 -- --
TA16R HETA16/TSS2, META16/TSS2
TA18 -- --
TA18R META18/TSS2 TA20 -- --
TA20R HETA20/TSS2, META20/TSS2
TA22 -- --
TA22R META22/TSS2
TA24 -- --
TA24R HETA24/TSS2, META24/TSS2
TA36 -- -- 1 30-3/4 8 10d x 1-1/2 1205 1205 245 335 8 10d x 1-1/2 2410 2410 2410 2410 490 670 130
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) Anchors are installed on opposite sides of the wood member, centered in masonry bond beam. 3) Minimum nail penetration shall be 1-1/2˝ for 10d nails. 4) Grout or concrete compressive strength shall be 2500 psi or greater at 28 days. 5) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 6) "R" after TA models indicates riveted truss anchors as in TA12R. 7) Allowable loads require a No. 4 rebar through the shear cones of the anchors. 8) Minimum quantity of fasteners to be installed. Product may have additional nail holes not needed to meet published allowable load of product.
L1,F17
L8
670490
490 670
2410 2410 490 6701 18-3/4 8 10d x 1-1/2
2410 2410 2410
1205 1205 245 335 10d x 1-1/2 2410 2410
8 10d x 1-1/2 2410
8
1 16-3/4 8 10d x 1-1/2 1205 1205 245
10d x 1-1/21205 1205 245 335 8
335
2410 2410 2410
6702410 2410 2410 490
24101 14-3/4 8 10d x 1-1/2
335 8 10d x 1-1/2 2410
2410 490 670
1 12-3/4 8 10d x 1-1/2 1205 1205 245
10d x 1-1/2 2410 2410 2410
L1,F17
1 10-3/4 8 10d x 1-1/2 1205 1205 245 335 8
2220 2220 490 6707 10d x 1-1/2 2410 24101205 1110 245 3351 8-3/4 7 10d x 1-1/2
MinQty.7
CodeRef.
USPStock No.
Out
of C
oncr
ete Single Anchor
Fastener Schedule3,5
MinQty.7
Per Anchor
S-P-FDF-L / SP
Double Anchor
Allowable Loads (Lbs.)1,6
Allowable Loads (Lbs.)1,6
Uplift Lateral Loads Uplift Lateral Loads
Fastener Schedule3,5
Per Anchor
TA20R
8 1/2˝
H
W
1 1/2˝
1˝
4˝embedment
F1
Uplift
F2
Typical TA16Rinstallation
USP2173-111
Tru
ss &
Rafte
r
1-800-328-5934 • www.USPconnectors.com 149
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®Embedded Truss Anchors – DTC
Typical DTCinstallation
The DTC series attaches trusses to concrete or masonrywalls. Innovative seat design gives added lateral resistancewhile still providing a moisture barrier.
Materials: 16 gaugeFinish: G90 galvanizingCodes: Dade County, FL 07-1003.10,
FL578
Installation:• Use all specified fasteners. See Product Notes, page 11.• Embed 4˝ into concrete tie beam or masonry bond beam.• Installations should be spaced no closer together than 8˝ center-to-center.
Ref. No. H Qty Type Qty Type F2 Uplift F2 Uplift
DTC HETAL12, HETAL16, HETAL20
16 16 4 10d x 1-1/2 9 10d x 1-1/2 840 1200 1290 1825 840 1200 1290 1440 F9, D8
1) Allowable loads have been increased 60% for wind and seismic loads; no further increase shall be permitted. 2) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 3) Grout or concrete compressive strength shall be 2500 psi or greater at 28 days. 4) Allowable loads require a No. 5 rebar through the shear cones of the anchors. New products or updated product information are designated in bold font.
USPStock No.
SteelGauge
TowardStrap
Awayfrom Strap
TowardStrap
Awayfrom Strap
CodeRef.
Fastener Schedule2
Out
of
Con
cret
e
F1 F1
Allowable Loads (Lbs.)1
DF-L / SP (160%) S-P-F (160%)Seat Plate Truss/Rafter
H
4˝embedment
11/4˝
DTC
RUSC
The RUSC Retro Uplift Strap Connector provides a wood-to-wood upliftconnection attaching trusses with a 2 x 4 bottom chord to a double stud inthe wall below. WS3 Wood Screws are utilized for fast installation. The connector can be installed after roof sheathing has been installed.
Materials: 10 gaugeFinish: USP primerCodes: FL6223
Installation:• Use all specified fasteners. See Product Notes, page 11.• The RUSC should be installed in pairs.• Install on minimum 2 ply with equal wall studs centered directly below.• Works with 2 x 4 bottom chord member and 2 x 4 wall studs.
Ref. No. Stud DF-L / SP S-P-F
RUSC -- -- 10 2 Ply or greater (16) WS3 (16) WS3 6040 5225 F26
1) Allowable loads are for a pair of RUSC devices. 2) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 3) Designer must specify stud or post to resist published load values. 4) WS3 Wood Screws are 1/4˝ x 3˝ long and are included with RUSC connectors. 5) Fastener schedule is for two straps used together. The RUSC shall be installed in pairs with a minimum 2 ply truss and wall stud attachment. 6) Truss plys shall be fastened together to act as a unit.
CodeRef.
Allowable Uplift 160%1
Fastener Schedule4,5
USPStock No.
SteelGauge
No, of
Plys6Rafter/Truss
3 1/2˝
3 1/8˝
3 1/8˝
22 3/4˝
7˝
Retrofit Strap Connector – RUSC
Typical RUSCinstallation
Materials: 10 gaugeFinish: USP primer
Installation:• Use all specified fasteners. See Product Notes,page 11. • Bolts must be ordered separately.• Place connector over truss or rafter and fasten withspecified fasteners.• Designer shall be responsible for design of masonry structure, including any required reinforcement.• For 2 ply applications, add filler block.• Works with heel heights up to 14˝.• Moisture barrier may be required.
Tru
ss &
Raft
er
1-800-328-5934 • www.USPconnectors.com150
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
Allowable Loads (Lbs.)
DF-L / SP
Uplift1
Description Ref. No. W H Qty Type Qty Bolt Dia. 160%8 16d 2 3/4 61708 16d 4 3/4 104008 16d 2 3/4 61708 16d 4 3/4 104008 16d 2 3/4 61708 16d 4 3/4 104008 16d 2 3/4 61708 16d 4 3/4 104008 16d 2 3/4 61708 16d 4 3/4 104008 16d 2 3/4 61708 16d 4 3/4 104008 16d 2 3/4 61708 16d 4 3/4 104008 16d 2 3/4 61708 16d 4 3/4 104008 16d 2 3/4 61708 16d 4 3/4 104008 16d 2 3/4 61708 16d 4 3/4 104008 16d 2 3/4 61708 16d 4 3/4 104008 16d 2 3/4 61708 16d 4 3/4 10400
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) Use Powers Fasteners 3/4˝ - 6˝ Wedge Bolts; or equal, installed in accordance with manufacturer's specifications. 3) Fasteners shall be installed to fully grouted and reinforced concrete masonry or reinforced concrete (f'c = 2000 psi at 28 days). 4) Bolts shall conform to ASTM A 307 or better. 5) Minimum nail embedment shall be 1-5/8˝ for 16d nails.
-- --
8/12 pitch
4/12 pitch
5/12 pitch
6/12 pitch
7/12 pitch
USC63
USC64
-- --
-- -- USC44
USC54
USC53
-- --
-- --
-- --
10
10
10
10
10
10
4 Ply Flat
USPStock
No.
SteelGauge
30-1/26-1/210
USC3F -- -- 10 3 Ply Flat
USC74 -- --
USC73
6-1/2
10
4-3/4
USC84 -- --
USC83 -- --
USC4F -- --
4-3/4 USC43 -- --
4-3/4
6-1/2
30-1/2
30-1/24-3/4
6-1/2
30-1/2
30-1/2
Dimensions
Rafter/ Truss5
6-1/2 30-1/2
10 4-3/4
10
Fastener Schedule2,3,4
10 6-1/2
30-1/2
30-1/2
4-3/4 30-1/2
130
CodeRef.
Concrete/Masonry Wall
30-1/2
30-1/2
30-1/2
6˝
4˝
2˝
2 1/2˝
7 1/2˝H
W
USC3F
Typical USC3F installationUGTS similar
Lintel Block with (1) #5continuous rebar
3/4˝ bolts. Use 2 or 4 as requiredfor uplift
7 1/2˝ Min.edge distance
8˝ concrete blockwith minimum(1) #5 rebar each cell continuous to footing withstandard hook at bolt locations
Uplift Girder Ties – USC series
4˝2˝
7 1/2˝
2 1/2˝
H
6˝Pitch
4/12˝ - 8/12˝W
Lintel Block with (1) #5continuous rebar
3/4˝ bolts. Use 2 or 4 as requiredfor uplift
7 1/2˝ Min.edge distance
8˝ concrete blockwith minimum(1) #5 rebar eachcell continuousto footing withstandard hook at bolt locations
Typical USC53 installation
USC53
The RFUS is a multi-purpose engineered solution for attaching trusses to concreteor masonry walls. Wedgebolt™ fastening eliminates mislocated cast-in-placeanchor bolts and allows retrofit installations. Works with heel heights up to 14˝.
Materials: 10 gaugeFinish: USP primerCodes: FL6223
Installation:• Always install in pairs.• Use all specified fasteners. See Product Notes, page 11.• Designer shall be responsible for design of masonry structure, includingany required reinforcement.• For 1 ply applications, add filler block. Refer to page 180 for wood fillerblock installation.• Moisture barrier may be required.
Allowable Loads (Lbs.)
DF-L / SP
Uplift1
Ref. No. Qty Type Qty Type 160%
RFUS FGTR 10 2 Ply > 12 WS3 4 3/4˝ x 6˝ Wedge Bolts 5500 F26
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) Use Powers Fasteners 3/4˝ x 6˝ Wedge Bolts; or equal, installed in accordance with manufacturer's specifications. 3) Fasteners shall be installed to fully grouted and reinforced concrete masonry or reinforced concrete (f'c = 2000 psi at 28 days). 4) Bolts shall conform to ASTM A 307 or better. 5) Fastener shedule is for two straps used together. The straps shall be installed in pairs. 6) Truss plys shall be fastened together to act as a unit. 7) WS3 Wood Screws are 1/4˝ x 3˝ long and are supplied with RFUS connector. New products or updated product information are designated in bold font.
Fastener Schedule3,5
Rafter/Truss7 Concrete/Masonry2,4
CodeRef.
USPStock No.
No. of
Plys6
SteelGauge
RFUS
Typical RFUS installation
Girder Tiedowns – LUGT series
5˝
30 1/2˝
4˝
5 1/2˝
3 3/16˝
14 13/16˝
Typical LUGTC2installation
Designed to provide light load alternatives for girder trusses in retrofit and newconstruction.
LUGT2 – Install on either the inside or outside of wall.
LUGTC2 – For corner hip applications.
Materials: 14 gaugeFinish: G90 galvanizingCodes: ESR-1465, FL817, FL568, Dade County, FL 07-0322.15
Installation:• Use all specified fasteners. See Product Notes, page 11.• All nail holes must be filled with specified nails to achieve loads listed in chart.Large holes are for alternative masonry installation and do not need to be filledwhen used for girder-to-stud application.• LUGT2 may be installed on either the inside or outside of wall.• Moisture barrier may be required.
LUGTC2
F1
continued on next page
USP2173-111
Uplift Girder Tie – RFUS series T
russ &
Rafte
r
1-800-328-5934 • www.USPconnectors.com 151
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
Tru
ss &
Raft
er
1-800-328-5934 • www.USPconnectors.com152
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®Girder Tiedowns – LUGT series continued
1 1/4˝
Typical MUGT15concrete installation
14 5/8˝
2 5/16˝3 11/16˝
1 1/4˝
Typical MUGT15wood installation
with PHD2
MUGT15
Ref. No. Qty Dia. Top Face Back Type
Face-Max 1 5/8 -- -- 28 -- -- 10d 4495
Top-Min 1 5/8 4 6 12 10d 4165
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) Additional anchorage products to be designed by others. 3) Minimum nail penetration shall be 1-1/2˝ for 10d nails. 4) Designer must specify anchor bolt type, length, and embedment.
Fastener Schedule2,3
Anchor Rafter/Truss3
CodeRef.
DF-L / SPAllowable
Uplift
160%1
1,F27
MUGT15 MGT 12
MountingCondition
USPStock No.
SteelGauge
Qty
Designed for higher uplift resistance for wood frame andconcrete block construction. The MUGT15 can accommodate variable truss bearing depths.
Materials: 12 gaugeFinish: G90 galvanizingCodes: ESR-1178, FL11910
Installation:• Use all specified fasteners. See Product Notes, page 11.• When straps are wrapped over the truss, install nails inbackside of truss. See MUGT15 installation diagram forminimum nail requirements into the face and on top of thetruss.• If installed straight-up with no wrap over the top of thetruss, fill all nail holes.• Moisture barrier may be required.
1 1/4˝
Install a minimumof (4) 10d nailsinto the top
Install a minimumof (6) 10d nailsinto the face
PHD2Apage 36
F1
Uplift
F2
3 1/4˝
12 7/8˝
Typical LUGT2wood installation
Typical LUGT2masonry installation
F1 F2 Uplift F1 F2 Uplift
Ref. No. Qty Type Qty Type Qty Type 160% 160% 160% 160% 160% 160%
LUGT2 LGT2 14 16 10d 2 10d 14 10d 1015 440 2260 850 370 190011, F3,
F12, D6
LUGTC2 -- -- 14 16 10d 2 10d 14 10d 575 -- -- 2260 480 -- -- 1900 11, F12
LUGT2 LGT2 14 16 10d -- -- -- -- 51/4˝ x 3˝
Wedge Bolts1220 460 1850 1025 265 1810
11, F3,F12, D6
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) Additional anchorage products to be designed by others. 3) Use Powers Fasteners 1/4˝ x 3˝ Wedge-Bolt®; or equal, installed in accordance with manufacturer's specifications. 4) Fasteners shall be installed to fully grouted and reinforced concrete masonry or reinforced concrete (f'c = 2000 psi at 28 days). 5) Minimum nail penetration shall be 1-1/2˝ for 10d nails.
Masonry Application
S-P-FRafter/Truss Plate Stud4,5 DF-L / SP
USPStock No.
SteelGauge
Allowable Loads (Lbs.)1,2Fastener Schedule2
CodeRef.
LUGT2
Girder Tiedown – MUGT15
Connects trusses directly to masonry or concrete and features slottedbase holes to ease installation.
Materials: Angle – 3 gauge; Gussets – 10 gaugeFinish: USP primerCodes: 2031C, FL859
Installation:• Use all specified fasteners. See Product Notes, page 11.• Bolts must be ordered seperately.• Install directly flush to masonry wall.• The SHA series connectors shall be installed in pairs.• Moisture barrier may be required.
USP2173-111
Tru
ss &
Rafte
r
1-800-328-5934 • www.USPconnectors.com 153
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
HTT22(not included)
see page 37
Masonry Uplift Connectors – SHA series
The HUGT series high uplift girder tiedowns can beinstalled on beams and top chords of trusses with slopesfrom 0˚ to 34˚.
Materials: 7 gaugeFinish: USP primerCodes: FL6223
Installation:• Use all specified fasteners. See Product Notes, page 11.• Install the HUGT over the beam or truss (see “W” dimension on chart for appropriate width).• Install (4) LBP58-TZ washers if (2) 5/8˝ tension bolts areused (wood installation) or (2) 3/4˝ dia. washers if a 3/4˝ dia.anchor bolt is used (concrete installation).• Attached members shall be designed to resist appliedloads.• Moisture barrier may be required.
Typical HUGT2wood-to-concrete
installation
W
Wood Installation(4) LBP58-TZ washersare required if 5/8˝ dia.bolt is used (washer notincluded) see chart onthis page
2 3/16˝2 7/8˝
4˝
Concrete Installation(2) 3/4˝ washers are
required if 3/4˝ dia. bolt isused (washer not included)
HUGT
Typical HUGT3wood-to-wood
installationwith HTT22’s
Girder Tiedowns – HUGT series
F1
Uplift
F1 Uplift
Ref. No. Qty Dia. Qty Dia. 160% 160%
2 Ply 4005 3745
3 Ply or greater 5565 5615
2 Ply 1590 3 Ply or greater 2190
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) Allowable loads are for a pair of SHA devices. SHA's shall be installed in pairs. 3) Fastener schedule is for a pair of SHA devices. 4) 1/2˝ x 8˝ J-Bolts or equivalent. 5) Concrete compressive strength shall be 2500 psi or greater at 28 days. 6) Multiple ply truss shall be fastened together to act as a single unit. 7) Bolts shall conform to ASTM A 307 or better. 8) The designer must specify anchor bolt type, length, and embedment.
4 3/4
4 3/4
1/2
1/2
2
2 SHA6T
-- --
-- --
USPStock No.
SHA6
CodeRef.
L1, F17
Allowable Loads (Lbs.)1,2Fastener Schedule3
No.
of Plys6
DF-L / SPConcrete Wall Rafter/Truss7
Anchor Bolts4,5,8
8370
1 1/2˝6˝
12 3/4˝
2 1/2˝
2 1/2˝
13 3/4˝
1 1/2˝ 4 1/4˝
6˝
2 1/4˝
2 1/4˝
3 1/4˝
SHA6 SHA6T
Typical SHA6installation
Typical SHA6Tinstallation
DF-L / SP S-P-F
Ref. No. W Qty Type Qty Bolt Dia. Qty Type 160% 160%
Wood 4 LBP58-TZ 2 5/8Concrete -- -- -- -- 2 3/4
Wood 4 LBP58-TZ 2 5/8
Concrete -- -- -- -- 2 3/4Wood 4 LBP58-TZ 2 5/8
Concrete -- -- -- -- 2 3/4
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) Listed loads apply where roof pitch is between 3:12 and 8:12. 3) Additional anchorage products to be designed by others. 4) Minimum nail penetration shall be 1-1/2˝ for 10d nails. 5) Designer must specify anchor bolt type, length, and embedment.
CodeRef.
F26 HGT-3
HGT-4 8
3-5/16
4-15/16
InstallationType
O.C. DimBetweenAnchors
8
Anchor Washers
Fastener Schedule3
Threaded Rod Girder4
USPStock No.
SteelGauge
7
6-7/8
7
HUGT2
HUGT3
7 HUGT4
HGT-2 5-3/4
7-3/8
10d9
10d
10d8
Allowable Loads (Lbs.)1,2
9860
7020
9650
9860
9860
9790
Designed as a retrofit connector for trusses installed on topplates. Can also be used as a holdown for a roof orfloor system.
Materials: 18 gaugeFinish: G90 galvanizingCodes: FL10739
Installation:• Use all specified fasteners. See Product Notes, page 11.• Tapcon® Concrete Screws are not supplied with RT16Mconnector.• Install Tapcon® Concrete Screws in lower two holes forSingle Top Plate or Conventional Raised Foundation orModular Home Installations.• Moisture barrier may be required.
Tru
ss &
Raft
er
1-800-328-5934 • www.USPconnectors.com154
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®Hurricane Gusset Angles – HGA series
F2
F3
F1
Uplift
Typical HGA10 installation
3 1/2˝
3˝
2˝
Embossedgussets improve
lateral loadresistance
Ref. No. Qty Type Qty Type F1 F2 F3 Uplift
HGA10 HGA10KT 14 4 WS15 4 WS3 1320 1565 835 1285 11, F12
HGAM10 HGAM10KTA, S/HGAM10KT
14 4 WS15 4 1/4˝ 1075 1110 740 915 130
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) WS15 Wood Screws are 1/4˝ x 1-1/2˝ long and WS3 Wood Screws are 1/4˝ x 3˝ long. 3) Use Powers Fasteners 1/4˝ x 1-1/4˝ Wedge-Bolt® (included); or equal. Drill hole in concrete or masonry with 1/4˝ masonry drill. Refer to manufacturer's literature for further information.
CodeRef.
Allowable Loads (Lbs.)1
USPStock No.
SteelGauge
Fastener Schedule2
Rafter/Truss Plate3 DF-L / SP (160%)
HGA10
Hurricane Retrofit Connector – RT16M
continued on next page
Designed for attaching gable end trusses to woodtop plates and masonry walls.
HGA10 – Versatile wood-to-wood connector thatsatisfies high wind and seismic loading requirements.
HGAM10 – For installation into grouted concretetie beam or masonry bond beam. Provides lateraland uplift resistance.
Materials: 14 gaugeFinish: G90 galvanizingCodes: ESR-1465, FL817
Installation:• Use all specified fasteners. See Product Notes,page 11.• HGAM10 – Install USP’s WS15 Wood Screwsinto the truss and drill holes for wedge bolts. Installwedge bolts into concrete block per manufacturer’srecommendation.• HGA10 – Install with USP’s WS3 Wood Screwsinto top plate, and WS15 Wood Screws into thetruss.• WS Wood Screws are included with HGA10angles.• WS Wood Screws and Wedge bolts are includedwith HGAM10 angles.• Moisture barrier may be required.
3 1/2˝
3˝
2 7/8˝
Embossedgussets improve
lateral loadresistance
HGAM10
Typical HGAM10 installation
Moisture barriernot shown
F1
F2
Typical RT16Mtop plate
installation
5˝
1 9/16˝
8 15/16˝
3 1/2˝
RT16M
USP2173-111
Hurricane Retrofit Connector – RT16M continuedT
russ &
Rafte
r
1-800-328-5934 • www.USPconnectors.com 155
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
Hurricane/Seismic Anchors – HC520, HCPRS, HHCP2, & RT series
These anchors tie trusses and rafters to top plates and may be used to tiewood framing members to resist uplift and lateral forces.
Materials: See chartFinish: G90 galvanizing; RT7A-GC & RT15-GC – Gold Coat
Options: HHCP2, RT3A, RT4, RT5, RT7, RT7A, RT10, RT15, RT8A,RT16A, and RT16-2 are available in Triple Zinc. To order, add TZ to stock number, as in RT10-TZ.RT3A, RT4, RT5, RT7, RT8A, RT10, RT16A, and RT16-2are available in Stainless Steel. To order, add SS to stocknumber, as in RT7-SS.
Codes: ESR-1881, ESR-1465, 2031C, FL565, FL821, FL817, FL859, Dade County, FL 07-0306.10, L.A. City RR 25779
5 1/4˝
1 9/16˝
HCPRSTypical HCPRS
stud to plate installation
4˝
2˝
1 5/8˝
1 1/2˝
HC520Typical HC520
stud to plate installation
Typical HC520gable brace installation
Hurricane Anchor installation to achieve twice the load (Top View)
Install diagonally across from eachother for minimum 1 1/2˝ truss. Thisinstallation yields full catalog values.
Wall Top Plate
Typical HHCP2truss/rafter to double plate
corner installation
F1
F1
Uplift
3˝
1 5/8˝
6 5/8˝
HHCP2Nailing into both sides of a single ply 2xtruss will result in reduced values.
DF-L / SP S-P-F
Ref. No. Qty Type Qty Type Qty Type F1 F2 F3 160% 160%
9 10d x 1-1/2 -- -- -- -- 4 1/4" x 1-3/4" Tapcon 630 480 115 1395 1395
9 10d x 1-1/2 4 16d 2 1/4" x 1-3/4" Tapcon -- -- -- -- -- -- 1360 1360
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 3) Install with 1/4" x 1-3/4" Tapcon® Concrete Screws in accordance to manufacturer's installation specifications. 4) Fasteners to be installed to fully grouted and reinforced concrete masonry.
Fastener Schedule2,3,4 Allowable Loads (Lbs.)1
CodeRef.
F19
Masonry Block UpliftLateral 160%
HM9KT RT16M
Truss/Rafter Top Plate
USPStock No.
18
SteelGauge
continued on next page
Tru
ss &
Raft
er
Hurricane/Seismic Anchors – HC520, HCPRS, HHCP2, & RT series cont.
1-800-328-5934 • www.USPconnectors.com156
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
4˝
6 1/2˝
2 7/16˝
1 1/2˝
1 1/2˝
RT7A
F1
F2
Typical RT7Atruss/rafter to double
plate installation
2 3/8˝
3 1/16˝
10 3/4˝
1 9/16˝1 1/4˝
1 1/4˝
7 13/16˝
4 15/16˝
RT10
Typical RT10truss/rafter
to double plate tostud installation
RT8A
Typical RT8Astud to double
plate installation
continued on next page
1 3/8˝
2 15/16˝
5 1/4˝
1 9/16˝
1 1/2˝
1 1/2˝
1 7/16˝
4 1/2˝
2 1/2˝
1 3/8˝
1 9/16˝
3 9/16˝
1 7/8˝
3 3/4˝
1 1/4˝
2˝RT4
Typical RT7truss/rafterto double
plate installation
RT6
1 7/8˝
5 1/4˝
2 7/8˝
1 15/16˝
RT5RT3A
RT7
Typical RT6truss/rafterto double
plate installation
Typical RT3Atruss/rafter
to plate installation
Typical RT4truss/rafter to
plate installation
Typical RT5truss/rafterto double
plate installation
USP2173-111
Tru
ss &
Rafte
r
157
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®Hurricane/Seismic Anchors – HC520, HCPRS, HHCP2, & RT series cont.
Typical RT20truss/rafter to double
plate to stud installation
5˝
3 1/2˝
6 1/2˝
1 9/16˝
RT16A
1 9/16˝
2 5/8˝
5 1/4˝
RT15
Typical RT15truss/rafter todouble plateinstallation
Uplift Uplift 160% Uplift Uplift 160%
Ref. No. Qty Type Qty Type Qty Type F1 F2 160% 8d x 1-1/2˝ F1 F2 160% 8d x 1-1/2˝
RT3A H3, H3S 18 4 8d 4 8d -- -- -- -- 190 190 610 610 160 160 525 525
RT4 H4 18 4 8d 4 8d -- -- -- -- 215 215 410 410 180 180 345 345
RT5 H5 18 4 8d 4 8d -- -- -- -- 265 265 540 540 225 225 450 450 RT6 HS24 18 8 10d x 1-1/2 6 10d x 1-1/2 -- -- -- -- 800 800 665 665 670 670 560 560 11, F12
RT7 H2.5, H2.5T, S/H2.5
18 5 8d 5 8d -- -- -- -- 195 195 585 585 160 160 495 49511,
F12,D5
RT7A H2.5A 18 5 8d 5 8d -- -- -- --
RT7A-GC -- -- 18 5 N8-GC 5 N8-GC -- -- -- --
RT8A H8 18 5 10d x 1-1/2 5 10d x 1-1/2 -- -- -- -- 215 215 775 775 180 180 650 650 RT10 H2, S/H2 18 6 8d 8 8d 6 8d 195 195 585 585 160 160 495 495 11, F12, D5
RT15 H1 18 5 8d x 1-1/2 5 8d -- -- -- -- RT15-GC -- -- 18 5 N8-GC 5 N8C-GC -- -- -- --
RT16A H10, H10A, H14
18 9 10d x 1-1/2 8 10d -- -- -- -- 800 645 1380 1380 670 545 1160 1160 11, F12
RT16-2 H10-2 18 8 8d 8 8d -- -- -- -- 655 415 1160 1160 550 345 975 975 11, F12
HHCP2 HCP2 18 10 10d x 1-1/2 10 10d x 1-1/2 -- -- -- -- 370 -- -- 800 800 310 -- -- 670 670 11, F12
HC520 GBC 18 -- -- -- -- 11 8d 6 8d 470 430 515 515 405 370 445 445 L1, F17 HCPRS -- -- 18 -- -- -- -- 5 8d 6 8d x 1-1/2 500 340 540 540 375 285 455 455 6, F15, R13
RT20 -- -- 16 9 10d x 1-1/2 4 10d 9 10d x 1-1/2 -- -- -- -- 1200 1200 -- -- -- -- 1005 1005 11, F12, D5
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) 8d common nails may be substituted for 8d x 1-1/2 nails, and 10d common nails may be substituted for 10d x 1-1/2 nails. 3) 8d x 1-1/2 nails are 11 gauge (0.131˝ diameter) by 1-1/2˝ long. 4) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 5) Minimum nail penetration shall be 1-5/16˝ for 8d nails and 1-1/2˝ for 10d nails.
CodeRef.
11, F1,F12, D5
Lateral 160% Lateral 160%
175 175210 210 670
500 445445
Fastener Schedule2,3,4,5 Allowable Loads (Lbs.)1
Truss/Rafter Plate Stud
USPStock No.
SteelGauge
S-P-FDF-L / SP
11, F12
11, F12
340 530
565670
285 410530
565
2 1/4˝
4 5/8˝
21 1/8˝
4 1/4˝
3 1/2˝
6 1/2˝
3 1/8˝6 1/2˝
RT16-2 RT20
Typical RT16-2truss/rafter to double
plate installation
Typical RT16Atruss/rafter to double
plate installation
Installation:• Use all specified fasteners. See Product Notes, page 11.• All nail holes must be filled with specified nails to achieve loadslisted in the chart.• Depending on pitch, birdsmouth notching may be required withsome models to enable installers to fill all nail holes.• Designer shall determine if solid blocking is required.
In some applications rafter ties arerequired by the codes to connectroof assemblies to the wall below. IRC 802.10.5, IBC 2308.10.1.
1-800-328-5934 • www.USPconnectors.com
Pla
ted T
russ
1-800-328-5934 • www.USPconnectors.com158
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
Truss Hangers . . . . . . . . . .Pages 160-165• THD SeriesMedium-to-heavy capacity face mount hanger.
• THDH SeriesHeavy capacity face mount hanger.
• HUS SeriesMedium capacity face mount hanger with double shear nailing.
• CLPBF SeriesMedium capacity 2 x 4 hanger.
• MSH SeriesField adjustable top or face mount strap hanger.
Skewed Truss Hangers . . .Pages 166-168• MSH213L/RSkewed 45° floor truss hanger.
• MSSH217L/RSeverely skewed strap hanger for angles 60° to 85°.
• SNP3Adjustable nail plate for connecting square cut trusses at skews up to60°.
Hip/Jack Connectors . . . .Pages 169-170• BN SeriesFace mount hanger for four mono trusses.
• HJC SeriesFace mount hanger for one hip and one jack truss.
• HTHJ SeriesLight capacity face mount hanger for one hip and one jack truss.
• HHC SeriesFace mount hanger for two hip trusses.
• HJHC SeriesFace mount hanger for two hip and one jack truss.
Girder Truss Hangers . . .Pages 171-173• GT, GTD, & GTS SeriesGirder truss hanger bolts to a supporting truss.
• GTWS SeriesGirder truss hanger with high uplift capacity screws to a supporting truss.
MSH
MSSH217Rright shown
HHC
HTHJ
GTGTD
GTWS
BN
HJHC
HJC
SNP3
HUSTHD THDH
continued on next pagecontinued on next page
GTS
MSH213Lleft shown
CLPBF
Plated Truss
USP2173-111
1-800-328-5934 • www.USPconnectors.com 159
©C
op
yrig
ht
2011
US
PS
tru
ctu
ralC
on
nec
tors
®Plated Truss
Truss Clips . . . . . . . . . . . . . .Page 173-174• STC SeriesA scissor truss clip with slotted nail holes for horizontal movement.
• FTC SeriesA floor truss clip to transfer loads between floor truss plys.
Supplemental Bearing Plates . .Page 175• SBP SeriesConnects to truss at bearing locations to distribute concentrated loads.
Roof Truss Ties . . . . . . . . . . . . . . .Page 176• TR SeriesProvides lateral support for non-load bearing walls whileallowing floor and roof trusses to deflect.
• HTC SeriesHigh capacity deflection clip
Blocking Supports . . . . . . . . . . . .Page 176• ZC SeriesSupports blocking between trusses and joists.
Field Splice Kits . . . . . . . . . . . . . .Page 177• FS & FSS SeriesField connectors for scissor truss splices.
Truss Spacers . . . . . . . . . .Pages 178-179• ST24H The Stabilizer™Truss brace and spacer that connects with prongs.
• TS & TSX SeriesTruss spacer that connects with nails.
Drag Strut Connectors . . . . . . .Page 179• LDSC4/DSC4Transfers lateral load from a truss to a bearing wall.
Alternate Installations . . . . . . . .Page 180• Backer block installations
• Panel point installations
• Filler block installations
STC
SBP
FTC
TR HTC
ZC
FS
TS
LDSC4L-left shown
TSX
ST24H
FSS
DSC4R-right shown
Pla
ted
Tru
ss
Typical THD210installation
Pla
ted T
russ
1-800-328-5934 • www.USPconnectors.com160
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
Floor Uplift1
Ref. No. W H D Qty Type Qty Type 100% 115% 125% 160%
2 x 6 - 8 THD26 HTU26 16 1-5/8 5-1/16 3 18 16d 12 10d x 1-1/2 2485 2855 3060 2170
2 x 8 - 10 THD28 HTU28 16 1-5/8 7 3 28 16d 16 10d x 1-1/2 3865 3965 3965 2330
2 x 10 - 12 THD210 HTU210 16 1-5/8 9 3 38 16d 20 10d x 1-1/2 5075 5115 5115 3095 (2) 2 x 6 - 8 THD26-2 HHUS26-2, HTU26-2 14 3-7/16 5-3/8 3 18 16d 12 10d 2540 2920 3175 2285
(2) 2 x 8 - 10 THD28-2 HHUS28-2, HTU28-2 14 3-7/16 7-1/8 3 28 16d 16 10d 3950 4540 4935 2595
(2) 2 x 10 - 12 THD210-2 HHUS210-2, HTU210-2 14 3-7/16 9-1/8 3 38 16d 20 10d 5360 6160 6700 3810 4 x 6 - 8 THD46 HHUS46 14 3-5/8 5-5/16 3 18 16d 12 10d 2540 2920 3175 2285
4 x 8 - 10 THD48 HHUS48 14 3-5/8 7-1/16 3 28 16d 16 10d 3950 4540 4935 2595 4 x 10 -12 THD410 HHUS410 14 3-5/8 9-1/16 3 38 16d 20 10d 5360 6160 6700 3810
4 x 12 - 14 THD412 -- -- 14 3-5/8 11 3 48 16d 20 10d 6770 7045 7045 3810
4 x 14 - 16 THD414 -- -- 14 3-5/8 12-7/8 3 58 16d 20 10d 7045 7045 7045 3810 5, F30, R5 (3) 2 x 10 - 12 THD210-3 HHUS210-3 12 5-1/8 9 3 38 16d 20 10d 5660 6510 7045 3850 5, F18, F30, D2, R5
6 x 10 -12 THD610 HHUS5.50/10 12 5-1/2 9 3 38 16d 20 10d 5660 6510 7080 3410
6 x 12 - 14 THD612 -- -- 12 5-1/2 11 3 48 16d 20 10d 7150 8225 8415 4065
6 x 14 - 16 THD614 -- -- 12 5-1/2 12-7/8 3 58 16d 20 10d 8415 8415 8415 4065 5, F30, R5
7 x 9-1/4 - 14 THD7210 HHUS7.25/10 12 7-1/4 9 3 38 16d 20 10d 5660 6510 7080 3410 5, F18, F30, D2, R5
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 3) Minimum nail penetration is 1-5/8˝ for 16d nails.
Dimensions Fastener Schedule2,3Allowable Loads (Lbs.)
Roof
DF-L / SPHeader Truss
5,F18,F30,D2,R5
5, F18,F10, F30, D2, R5
CodeRef.
Joist /Truss Size
USPStock No.
SteelGauge
See EWP applications pages 121-122.
Materials: See chartFinish: G90 galvanizing
Options: See Specialty Options Chart. Rough/Full sizes available. THD hangers with widths greater than 3˝ can have one flange inverted with no load reduction. Specify right (R) or left (L).
Codes: ESR-1781, FL9835, FL13285, Dade County, FL 06-0921.05, L.A. City RR 25843
Installation:• Use all specified fasteners. See Product Notes, page 11.
Option Skewed1,3 Sloped Seat2,3 Sloped / Skewed1,2,3 Inverted Flange
1) Skewed hangers with skews greater than 15° may have all joist nailing on outside flange. 2) Sloped or sloped / skewed hangers with slopes greater than 15° may have additional joist nails. 3) All sloped, skewed, or combinations require bevel cut or sqare cut on joist in all applications.
RangeNot available in widths < 3˝.
Widths > 3 can haveone flange inverted.
1˚ to 45˚ 1˚ to 45˚ See Sloped Seat and Skewed
AllowableLoads
Ordering
85% of table load 65% of table load 65% of table load
100% of table load.65% of table load whennailing into the supportmembers end grain.
Add SK,angle required,and right (R) or left (L),
to product number.Ex. THD410-SK45R
Add SL,slope required,and up (U) or down (D),
to product number.Ex. THD410-SL30D
See Sloped Seat and Skewed.Ex. THD410-SK45RSL30D
Add 1IF,one flange,right (R) and left (L),to product number.Ex. THD4101IFR
Specialty Options Chart – refer to Specialty Options pages 194 to 195 for additional details.
D
H
W
Some model designsmay vary from
illustration shown
THD28
Heavy-Duty Face Mount Truss Hangers – THD series
Floor Uplift1Floor Uplift1
Ref. No. W H D Qty Type Qty Type 100% 115% 125% 160% 100% 115% 125% 160%
2 x 6 - 8 THDH26 HGUS26 1-5/8 5-7/16 5 20 16d 8 16d 3915 4505 4895 2340 3370 3880 4200 1965 6, F15, F18, D2, R13
2 x 8 - 10 THDH28 HGUS28 1-5/8 7-3/16 5 36 16d 12 16d 6770 7395 7395 4370 5830 6210 6210 3670 6, F15, F18, D2, R13
2 x 10 - 12 THDH210 -- -- 1-5/8 9-3/16 5 46 16d 16 16d 8725 9580 9600 5400 6835 7385 7750 4535 6, F15, R13 2-11/16 x 9-1/4 - 14 THDH27925 HGUS2.75/10 2-3/4 9-1/8 4 46 16d 12 16d 8260 8260 8260 3490 6935 6935 6935 2930 6, F15, F18, D2, R13
2-11/16 x 11-1/4 - 16 THDH27112 HGUS2.75/12 2-3/4 10-7/8 4 56 16d 14 16d 9845 9845 9845 5225 7655 8135 8270 4390 6, F15, R13 2-11/16 x 14 - 16 THDH2714 HGUS2.75/14 2-3/4 12-1/4 4 66 16d 16 16d 9845 9845 9845 6810 8110 8270 8270 5835 6, F15, R13
3-1/4 x 9-1/2 THDH3210 HGUS3.25/10 3-3/16 9-3/8 4 46 16d 12 16d 8260 8260 8260 3490 6935 6935 6935 2930 6, F15, F18, D2, R13
3-1/4 x 10-5/8 THDH3212 HGUS3.25/12 3-3/16 10-5/8 4 56 16d 14 16d 9845 9845 9845 5960 8270 8270 8270 5105 6, F15, R13 (2) 2 x 6 - 8 THDH26-2 HGUS26-2 3-7/16 5-3/8 4 20 16d 8 16d 3915 4505 4795 2235 3370 3880 4030 1880 6, F18, F15, D2, R13
(2) 2 x 8 - 10 THDH28-2 HGUS28-2 3-7/16 7-1/8 4 36 16d 10 16d 6535 7515 8025 2665 5635 6480 6740 2240 6, F15, R13 (2) 2 x 10 - 12 THDH210-2 HGUS210-2 3-7/16 9-1/8 4 46 16d 12 16d 8260 8260 8260 3490 6935 6935 6935 2930 6, F18, F15, D2, R13
4 x 6 - 8 THDH46 HGUS46 3-9/16 5-3/8 4 20 16d 8 16d 3915 4505 4895 2605 3370 3880 4215 2190 6, F18, F15, D2, R13
4 x 8 - 10 THDH48 HGUS48 3-9/16 7-1/8 4 36 16d 10 16d 6535 7515 7835 3185 5635 6480 6580 2675 6, R13 4 x 10 - 12 THDH410 HGUS410 3-9/16 9-1/8 4 46 16d 12 16d 8260 9010 9010 3970 7120 7570 7570 3335 6, F18, F15, D2, R13
4 x 12 - 14 THDH412 HGUS412 3-9/16 10-1/2 4 56 16d 14 16d 9845 9845 9845 5225 8270 8270 8270 4390 6, F15, R13
4 x 14 - 16 THDH414 HGUS414 3-9/16 13-1/6 4 66 16d 16 16d 9845 9845 9845 6810 8270 8270 8270 5835 6, F15, R13 (3) 2 x 6 - 8 THDH26-3 HGUS26-3 5-1/8 5-7/16 4 20 16d 8 16d 3915 4505 4795 2235 3370 3880 4030 1880 6, F18, F15, D2, R13
(3) 2 x 8 - 10 THDH28-3 HGUS28-3 5-1/8 7-3/16 4 36 16d 12 16d 6770 7785 8025 2665 5830 6705 6740 2240 6, F18, F15, D2, R13 (3) 2 x 10 - 12 THDH210-3 HGUS210-3 5-1/8 9-3/16 4 46 16d 16 16d 8725 9855 9855 4565 7520 8275 8275 3835 6, F15, F18, R13
(3) 2 x 12 - 14 THDH212-3 HGUS212-3 5-1/8 11-3/16 4 56 16d 20 16d 9935 9935 9935 5180 8345 8345 8345 4355 6, F15, R13
(3) 2 x 14 - 16 THDH214-3 HGUS214-3 5-1/8 13-3/16 4 66 16d 22 16d 11645 11645 11645 5795 9780 9780 9780 4865 6, F15, R13
6 x 10 - 12 THDH610 HGUS5.25/10, HGUS5.50/10
5-1/2 9 4 46 16d 16 16d 8725 9855 9855 4565 7520 8275 8275 3835 6, R13
6 x 12 - 14 THDH612 HGUS5.25/12, HGUS5.50/12
5-1/2 11 4 56 16d 20 16d 9935 9935 9935 5180 8345 8345 8345 4355 6, R13
6 x 14 - 16 THDH614 HGUS5.50/14 5-1/2 13 4 66 16d 22 16d 11645 11645 11645 5795 9780 9780 9780 4865 6, R13
6-3/4 x 9 - 14-1/2 THDH6710 HGUS210-4, HGUS6.88/10
6-7/8 8-13/16 4 46 16d 12 16d 8260 8260 8260 3490 6935 6935 6935 29306, F18,D2, R13
6-3/4 x 11 - 18 THDH6712 HGUS212-4, HGUS6.88/12
6-7/8 10-13/16 4 56 16d 14 16d 9845 9845 9845 5225 8270 8270 8270 4390 6, R13
6-3/4 x 13 - 20-1/2 THDH6714 HGUS214-4, HGUS6.88/14
6-7/8 12-13/16 4 66 16d 16 16d 9845 9845 9845 6810 8270 8270 8270 5835 6, R13
7-1/4 x 9-1/4 - 14 THDH7210 HGUS7.25/10 7-1/4 9 4 46 16d 12 16d 8260 9010 9010 3970 7120 7570 7570 3335 6, F18, D2, R13
7-1/4 x 11-1/4 - 16 THDH7212 HGUS7.25/12 7-1/4 10-1/2 4 56 16d 14 16d 9845 9845 9845 5225 8270 8270 8270 4390 6, R13
7-1/4 x 14 - 18 THDH7214 HGUS7.25/14 7-1/4 12-1/4 4 66 16d 16 16d 9845 9845 9845 6810 8270 8270 8270 5835 6, R13
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) Joist nails need to be toe nailed at a 30° to 45˚ angle to achieve allowable loads shown. 3) Minimum nail penetration shall be 1-5/8˝ for 16d nails.
Joist /Truss Size
USPStock No.
Dimensions Fastener Schedule2,3
Header Truss
CodeRef.
Allowable Loads (Lbs.)
Roof
DF-L / SP S-P-F
Roof
D
H
W
2 1/2˝Raised dimple allows
30˚ to 45˚ nailing
See EWP applications pages 121-122.
2 1/2˝
D
H
W
THDH
Materials: 12 gaugeFinish: G90 galvanizing
Options: See Specialty Options Chart.Codes: ESR-1881, FL821, FL9835,
Dade County, FL 06-0921.05
Installation:• Use all specified fasteners. See ProductNotes, page 11.• Joist nails must be driven in at a 30° to 45°angle through the joist or truss into the header toachieve listed loads. Standard length “doubleshear” nails must be used to achieve listedload values.
Drive joist nails into header at 30°to 45° to achieve listed loads. Typical THDH double
shear installation
Typical THDH26-2installation
THDH26-2
Option Skewed 1,3 Sloped Seat2,3 Sloped / Skewed1,2,3
Range 1˚ to 45˚ 1˚ to 45˚ See Sloped Seat and Skewed
1) Skewed THDH hangers with skews greater than 15° always have all joist nailing on one side of the outside flange. 2) Sloped or sloped / skewed hangers with slopes greater than 15° may have additional joist nails. 3) All sloped, skewed, or combinations require bevel cut on joist in all applications. Inverted flange option is not available for THDH models.
85% of table allowable loadAllowable
Loads85% of table allowable load.
50% of table uplift load.52% of table allowable load.
50% of table uplift load.
Ordering
Add SK, angle required,and right (R) or left (L),
to product number.Ex. THDH410-SK45R
Add SL, slope required,and up (U) or down (D),
to product number.Ex. THDH410-SL30D
See Sloped Seat and Skewed.Ex. THDH410-SK45RSL30D
Specialty Options Chart – refer to Specialty Options pages 194 to 195 for additional details.
Some model designs may varyfrom illustration shown
USP2173-111
Pla
ted
Tru
ss
1-800-328-5934 • www.USPconnectors.com 161
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®Heavy-Duty Truss Hangers – THDH series
H
2˝W
1˝
Pla
ted T
russ
1-800-328-5934 • www.USPconnectors.com162
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
Floor Uplift1Floor Uplift1
Ref. No. W H Qty Type Qty Type 100% 115% 125% 160% 100% 115% 125% 160%
MUS26 MUS26 18 1-9/16 5-1/16 6 10d 6 10d 1285 1475 1605 865 1100 1265 1375 725 110
HUS26 HUS26 16 1-5/8 5-7/16 14 16d 6 16d 2635 3030 3295 1925 2260 2600 2810 16156, F15, F18,
D2, R13
MUS28 MUS28 18 1-9/16 7-1/16 8 10d 8 10d 1710 1970 2140 1230 1465 1685 1830 1035 110
HUS28 HUS28 16 1-5/8 7-3/16 22 16d 8 16d 3970 4345 4345 2570 3410 3650 3650 2160
2 x 10 - 12 HUS210 HUS210 16 1-5/8 9-3/16 30 16d 10 16d 5310 5510 5510 3205 4095 4420 4630 2690
1-3/4 x 5-1/2 - 7-1/4 HUS175 HU1.81/5 16 1-13/16 5-3/8 14 16d 6 16d 2635 3030 3295 1925 2260 2600 2810 1615
1-3/4 x 7-1/4 - 11-1/4 HUS177 -- -- 16 1-13/16 7-1/8 22 16d 8 16d 3975 4345 4345 2570 3410 3650 3650 2160
1-3/4 x 9-1/4 - 14 HUS179 HUS1.81/10 16 1-13/16 9-1/8 30 16d 10 16d 5310 5510 5510 3205 4410 4630 4630 2690
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) Minimum nail penetration is 1-5/8˝ for 16d nails. 3) Nails must be driven at a 30° to 45° angle through joist or truss into header to achieve the table loads. 4) HUS175, HUS177, and HUS179 load values assume the joist is 1-3/4˝ wide and has a bearing strength of not less than 675 psi. New products or updated product information are designated in bold font.
CodeRef.
6, F15,F18, D2,
R13
Joist /Truss Size
USPStock No.
SteelGauge
2 x 6 - 8
2 x 8 - 10
Dimensions Allowable Loads (Lbs.)4Fastener Schedule2
Roof
DF-L / SP S-P-F
Roof
Header Truss3
H
2˝
3˝
Raised dimple allows30˚ to 45nailing
W
The MUS & HUS hanger series offers double shear nailing.USP’s raised dimple allows for 30° to 45° nailing throughthe joist into header, resulting in higher loads and less nailing.
Materials: See chartFinish: G90 galvanizingCodes: ESR-1881, FL9835,
Dade County, FL 06-0921.05
Installation:• Use all specified fasteners. See Product Notes, page 11.• Joist nails must be driven in at a 30° to 45° angle throughthe joist or truss into the header to achieve listed loads.Standard length “double shear” nails must be used toachieve listed load values.
See EWP applications pages 121-122.
Typical HUS installation(MUS similar)
CLPBF
2 1/2˝
2 1/2˝1 9/16˝
The butterfly hanger’s flared header flange design allows for added nailing.Excellent truss-to-truss hanger for 2x4 purlin or truss bottom chords.
Materials: 18 gaugeFinish: G90 galvanizingCodes: ESR-1881, FL574, Dade County, FL 08-0206.07
Installation:• Use all specified fasteners. See Product Notes, page 11.
Butterfly Hanger – CLPBF
HUS
MUS
Typical CLPBFinstallation
Floor Uplift1
Joist Size Ref. No. Qty Type Qty Type 100% 115% 125% 160%
2 x 4 CLPBF -- -- 18 12 10d 6 10d x 1-1/2 815 815 815 2156, F7, F15,D11, R13
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) Minimum nail embedment shall be 1-1/2˝ for 10d nails.
CodeRef.
USPStock No.
SteelGauge
Allowable Loads (Lbs.)
Roof
DF-L / SPHeader Joist
Fastener Schedule2
Double shear nail designfeatures fewer nails and
faster installation
Uses standard length nails
Slant Nail Truss Hangers – MUS & HUS series
NEW
USP2173-111
Pla
ted
Tru
ss
1-800-328-5934 • www.USPconnectors.com 163
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®Adjustable Strap Hangers – MSH series
H
B
WD
MSH
continued on next page
MSH422
3 9/16˝
21 1/2˝
MSH426
W
H
B
D
MSH422IF3 5/8˝
22˝
The MSH is field adjustable. The flanges can be used in top mount, face mount, or combinationinstallations. An open back design allows installation after a member is placed in position.
Materials: See chartFinish: G90 galvanizingCodes: ESR-1831, FL567, FL822, Dade County, FL 08-0303.06, L.A. City RR 25836
Installation:• Use all specified fasteners. See Product Notes, page 11.• Web stiffeners are required for I-Joist installations.Mounting condition:Face-Max – Figure 1. All header nails used should be driven into the wide face of the header.Top-Max – Figure 2. The hanger is installed in a top mount condition with at least six lower header face nail holes filled, and four top flange nails filled. The strap must wrap over the top atleast 2˝.Top-Min – Figure 3. The hanger is installed in a top mount condition with at least the top two header face nail holes filled, and four top flange nail holes filled. The strap must wrap over the topat least 2˝ and the joist nails shall be installed straight into the joist for all models.Combination – Figure 4. Face-Max values apply for the entire connection. Follow fastening directions above for the applicable mounting condition for each individual flange strap.
Typical combinationMSH installation
Typical MSH installationFace Mount Maximum
Figure 1
Typical MSH installationTop Mount Maximum
Figure 2 Figure 3
Typical MSH422-2IFinstallation Top Mount
Minimum
Figure 4
Double shear nail designfeatures fewer nails and
faster installation
Uses standard length nails
Pla
ted T
russ
1-800-328-5934 • www.USPconnectors.com164
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
Top Face Floor Uplift1Floor Uplift1
Ref. No. W D H B Qty Qty Type Qty Type 100% 115% 125% 160% 100% 115% 125% 160%
face-max -- -- 18 10d 4 10d 2445 2635 2680 785 1825 1885 1925 660
top-max 4 6 10d 4 10d 2565 2635 2680 785 1825 1885 1925 660
top-min 4 2 10d 4 10d x 1-1/2 2425 2425 2425 -- -- 1820 1880 1920 -- --
face-max -- -- 20 10d 4 10d 2565 2635 2680 785 1825 1885 1925 660
top-max 4 6 10d 4 10d 2565 2635 2680 785 1825 1885 1925 660
top-min 4 2 10d 4 10d x 1-1/2 2425 2425 2425 -- -- 1820 1880 1920 -- --
face-max -- -- 26 10d 4 10d 2565 2635 2680 785 1825 1885 1925 660
top-max 4 6 10d 4 10d 2565 2635 2680 785 1825 1885 1925 660
top-min 4 2 10d 4 10d x 1-1/2 2425 2425 2425 -- -- 1820 1880 1920 -- --
face-max -- -- 22 10d 4 10d x 1-1/2 2090 2155 2200 595 1505 1560 1600 500
top-max 4 6 10d 4 10d x 1-1/2 2090 2155 2200 595 1505 1560 1600 500
top-min 4 2 10d 4 10d x 1-1/2 2090 2155 2165 -- -- 1505 1560 1600 -- --
face-max -- -- 22 10d 4 10d x 1-1/2 2200 2200 2200 595 1850 1850 1850 500
top-max 4 6 10d 4 10d x 1-1/2 2600 2600 2600 595 2185 2185 2185 500
top-min 4 2 10d 4 10d x 1-1/2 2165 2165 2165 -- -- 1820 1820 1820 -- --
face-max -- -- 16 10d 4 10d 1855 2135 2320 605 1600 1840 2000 510
top-max 4 6 10d 4 10d 3430 3485 3485 605 2460 2550 2610 510
top-min 4 2 10d 4 10d 2210 2210 2210 -- -- 1855 1855 1855 -- --
face-max -- -- 22 10d 4 10d 2550 2935 3190 605 2200 2530 2730 510
top-max 4 6 10d 4 10d 3430 3485 3485 605 2460 2550 2610 510
top-min 4 2 10d 4 10d 2210 2210 2210 -- -- 1855 1855 1855 -- --
face-max -- -- 14 10d 6 10d 2210 2545 2765 1570 1900 2185 2375 1320
top-max 4 6 10d 6 10d 3525 3525 3525 1570 2955 2960 2960 1320
top-min 4 2 10d 6 10d 2025 2025 2025 -- -- 1700 1700 1700 -- --
face-max -- -- 18 10d 6 10d 2675 3075 3345 1570 2300 2645 2875 1320
top-max 4 6 10d 6 10d 3525 3525 3525 1570 2955 2960 2960 1320
top-min 4 2 10d 6 10d 2025 2025 2025 -- -- 1700 1700 1700 -- --
face-max -- -- 22 10d 6 10d 3140 3470 3470 1570 2700 2915 2915 1320
top-max 4 6 10d 6 10d 3525 3525 3525 1570 2955 2960 2960 1320
top-min 4 2 10d 6 10d 2025 2025 2025 -- -- 1700 1700 1700 -- --
face-max -- -- 22 10d 4 10d 2550 2935 3190 605 2200 2530 2750 510
top-max 4 6 10d 4 10d 3430 3485 3485 605 2460 2550 2610 510
top-min 4 2 10d 4 10d 2210 2210 2210 -- -- 1855 1855 1855 -- --
face-max -- -- 36 10d 6 10d 3960 3960 3960 1285 3325 3325 3325 1080
top-max 4 6 10d 6 10d 2965 2965 2965 1285 2490 2490 2490 1080
top-min 4 2 10d 6 10d 1550 1550 1550 -- -- 1300 1300 1300 -- --
top-max 4 8 16d 6 16d 3855 3855 3855 1715 3050 3235 3235 1440
top-min 4 2 16d 6 16d 2735 2735 2735 -- -- 2295 2295 2295 -- --
face-max -- -- 26 16d 6 16d 3665 4215 4585 1175 3145 3620 3935 985
top-max 4 10 16d 6 16d 4535 4585 4585 1175 3335 3515 3640 985
top-min 4 4 16d 6 16d 3690 3775 3830 -- -- 2610 2680 2730 -- --
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 3) Minimum nail penetration shall be 1-1/2˝ for 10d nails and 1-5/8˝ for 16d nails.
CodeRef.
10,F2, F16,D12, R14
16
16
16
10, F16,R14
221-3/4 9-13/16
14
JoistMaterial& Width
USPStock No.
MountingConditionSt
eel G
auge
Fastener Schedule2,3Dimensions
DF-L / SP
Allowable Loads (Lbs.)
S-P-FHeader Joist
3-1/2˝ wideFloor
Trusses
(2) 3-1/2˝ wideFloor
Trusses
MSH426 MSH426IF
THA426 THAC426
MSH422-2 MSH422-2IF
THA422-2 THAC422-2
3-1/2˝ wideFloor Trusses
MSH422IF THAC418, THAC422
3-1/2˝ wideFloor
Trusses
7-1/4 22-1/82 11
3-5/8 1-3/4 26 8
7-5/8
7-5/8
7-5/8
17-1/2
21-1/2
(2) 2x Lumberor
Trusses
3-9/16
3-1/2˝ wideFloor
Trusses
3-1/2˝ wideFloor
Trusses
3-1/2˝ wideFloor
Trusses16 MSH422
THA422, THAI422
MSH222-2 THA222-2
2-1/2˝ wideFloor
Trusses
(2) 2x Lumberor
Trusses10-1/16
10-1/163-1/8
22-1/22-9/16
1-3/4
1-3/4
17-3/4
14
16
16
14
16
MSH218-2 THA218-2 3-1/8
MSH322 THAI322 18
THA2182x Lumber
orTrusses
THAI222 1-5/82x Lumber
orTrusses
MSH222
MSH218
18
18
18
1-5/8
2-1/4
231-3/4
2-1/4 16-3/4 5
1-5/8
2x Lumberor
Trusses MSH29 THA29
2x Lumberor
Trusses MSH213 THA213
18 8-3/4 5
Roof
12-3/4 5
Roof
MSH418 THA418
3-9/16
3-9/16
MSH413 THA413
1-5/8
10-13/16
2-1/4
MSH424 -- -- 3-5/8
10-3/8
22-1/4
1-3/4
1-3/4
1-3/4
1-3/4
3-5/8
10, F16,R14
2 22 5-3/1610, F16,D9, R14
Plated Truss chart
continued on next page
Adjustable Strap Hangers – MSH series continued
W
H
B
D
USP2173-111
Pla
ted
Tru
ss
1-800-328-5934 • www.USPconnectors.com 165
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
Top Face Floor Uplift1 Floor Uplift1
Ref. No. W D H B Qty Qty Type Qty Type 100% 115% 125% 160% 100% 115% 125% 160%
face-max -- -- 22 10d 4 10d x 1-1/2 2090 2155 2200 595 1505 1560 1600 500
top-max 4 6 10d 4 10d x 1-1/2 2090 2155 2200 595 1505 1560 1600 500
top-min 4 2 10d 4 10d x 1-1/2 2090 2155 2165 -- -- 1505 1560 1600 -- --
face-max -- -- 12 10d 4 10d 1370 1575 1710 595 1175 1350 1470 500
top-max 4 6 10d 4 10d 2370 2440 2485 595 1695 1750 1790 500
top-min 4 2 10d 4 10d x 1-1/2 2165 2165 2165 -- -- 1690 1750 1785 -- --
face-max -- -- 22 10d 4 10d x 1-1/2 2200 2200 2200 595 1690 1750 1785 500
top-max 4 6 10d 4 10d x 1-1/2 2360 2430 2475 595 1690 1750 1785 500
top-min 4 2 10d 4 10d x 1-1/2 2165 2165 2165 -- -- 1690 1750 1785 -- --
face-max -- -- 22 10d 4 10d x 1-1/2 2200 2200 2200 595 1850 1850 1850 500
top-max 4 6 10d 4 10d x 1-1/2 2600 2600 2600 595 2110 2165 2185 500
top-min 4 2 10d 4 10d x 1-1/2 2165 2165 2165 -- -- 1820 1820 1820 -- --
face-max -- -- 22 10d 4 10d x 1-1/2 2200 2200 2200 595 1850 1850 1850 500
top-max 4 6 10d 4 10d x 1-1/2 2600 2600 2600 595 2185 2185 2185 500
top-min 4 2 10d 4 10d x 1-1/2 2165 2165 2165 -- -- 1820 1820 1820 -- --
face-max -- -- 14 10d 6 10d 2210 2545 2765 1570 1900 2185 2375 1320
top-max 4 6 10d 6 10d 3525 3525 3525 1570 2955 2960 2960 1320
top-min 4 2 10d 6 10d 2025 2025 2025 -- -- 1700 1700 1700 -- --
face-max -- -- 18 10d 6 10d 2675 3075 3345 1570 2300 2645 2875 1320
top-max 4 6 10d 6 10d 3525 3525 3525 1570 2955 2960 2960 1320
top-min 4 2 10d 6 10d 2025 2025 2025 -- -- 1700 1700 1700 -- --
face-max -- -- 22 10d 6 10d 3140 3470 3470 1570 2700 2915 2915 1320
top-max 4 6 10d 6 10d 3525 3525 3525 1570 2955 2960 2960 1320
top-min 4 2 10d 6 10d 2025 2025 2025 -- -- 1700 1700 1700 -- --
face-max -- -- 22 10d 4 10d 2550 2935 3190 605 2200 2530 2750 510
top-max 4 6 10d 4 10d 3430 3485 3485 605 2460 2550 2610 510
top-min 4 2 10d 4 10d 2210 2210 2210 -- -- 1855 1855 1855 -- --
face-max -- -- 36 10d 6 10d 3960 3960 3960 1285 3325 3325 3325 1080
top-max 4 6 10d 6 10d 2965 2965 2965 1285 2490 2490 2490 1080
top-min 4 2 10d 6 10d 1550 1550 1550 -- -- 1300 1300 1300 -- --
top-max 4 8 16d 6 16d 3855 3855 3855 1715 3050 3235 3235 1440
top-min 4 2 16d 6 16d 2735 2735 2735 -- -- 2295 2295 2295 -- --
face-max -- -- 46 10d 4 10d 3365 3365 3365 605 2825 2825 2825 510
top-max 4 6 10d 4 10d 2885 2990 3060 605 2090 2180 2240 510
top-min 4 2 10d 4 10d 2210 2210 2210 -- -- 1690 1720 1740 -- --
face-max -- -- 46 10d 4 10d 3365 3365 3365 605 2825 2825 2825 510
top-max 4 6 10d 4 10d 2885 2990 3060 605 2090 2180 2240 510
top-min 4 2 10d 4 10d 2210 2210 2210 -- -- 1690 1720 1740 -- --
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 3) Minimum nail penetration shall be 1-1/2˝ for 10d nails and 1-5/8˝ for 16d nails. New products or updated product information are designated in bold font.
10, D9,R14
10, F16,D9, R14
10, D9,R14
10, F2,F16,
D12, R14
10, F16,R14
10, F2,F16,
D12, R14
16 -- --
1-3/4
7-5/8
3-5/8 2
3-9/16 1-3/416
3-9/16
CodeRef.
10, F2,F16,
D12, R142-9/16 1-3/4
Roof
1-3/4 23
1-3/4
10-7/16
9-13/1622
17-1/2
14 7-5/8
22-5/8
7-5/8
22 5-3/16
3-9/16 1-3/4
Header Joist
10-13/16
12-11/16 10-3/4
14 3-5/8
1-3/4
16
18
18
1-3/4
1-3/4
2-3/8 1-3/4
22-7/8 10-3/4
-- -- 4-3/4 1-3/4 22
18 1-13/16
10-3/8
21-1/2
1-3/4 22
16
16
Ste
el G
auge
JoistMaterial& Width
DF-L / SP
USPStock No.
MountingCondition
Roof
Allowable Loads (Lbs.)Fastener Schedule2,3
S-P-F
Dimensions
MSH1713 -- -- 18 1-13/16
MSH1722 THAI1.81/22
THA426 THAC426
THA422, THAI422
THA418
MSH424
MSH322 THAI322
MSH413
22-1/2
MSH418
9-1/4
9-1/4
826
MSH422
MSH426 MSH426IF
5-3/8
4-5/8˝ wideI-Joist
4-5/8˝ wideI-Joist
MSH2622-2 -- --
3-1/2˝ wideFloor Trusses
MSH2322-2
1-3/4˝ LVLor
I-Joist
1-3/4˝ LVLor
I-Joist
2-5/16˝ wideI-Joist
3-1/2˝ wideFloor
Trusses
2-1/2˝ wideFloor
Trusses
3-1/2˝ wideFloor
Trusses
3-1/2˝ wideFloor
Trusses
3-1/2˝ wideFloor
Trusses
3-1/2˝ wideFloor
Trusses
1-5/8
MSH422IF THAC418, THAC422
16 3-5/8
THA413 16
MSH2322 THAI3522
2x Lumberor
Trusses MSH222 THAI222 18
Adjustable Strap Hangers – MSH series continued
I-Joist, LVL, LSL, & PSL chart
Pla
ted T
russ
1-800-328-5934 • www.USPconnectors.com166
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
Drive nailsat angle
Left skewRight skew
The MSH213L/R is an adjustable 45º skew hangerdesigned to permit installation on a 2 x 6 or greater bottomchord, or vertical web member.
Materials: 18 gaugeFinish: G90 galvanizingCodes: ESR-1831, FL6223, FL822,
L.A. City RR 25836
Installation:• Use all specified fasteners. See Product Notes, page 11. • Web stiffeners are required for I-Joist installations.
Floor Uplift1Floor Uplift1
Ref. No. Qty Type Qty Type Qty Type 100% 115% 125% 160% 100% 115% 125% 160%
face-max -- -- -- -- 22 10d 6 10d x 1-1/2 1770 1770 1770 730 1485 1485 1485 615
top-max 4 10d 6 10d 6 10d x 1-1/2 1735 1735 1735 730 1455 1455 1455 730
top-min 4 10d 2 10d 6 10d x 1-1/2 1240 1240 1240 -- -- 1040 1040 1040 -- --
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 3) Minimum nail penetration shall be 1-1/2˝ for 10d nails.
CodeRef.
10, F16,F26, R14
Top Face Roof Roof
Header Joist
Fastener Schedule2,3
DF-L / SP
Allowable Loads (Lbs.)
S-P-F
2x Lumberor
Trusses MSH213L/R -- -- 18
JoistMaterial& Width
USPStock No.
SteelGauge
MountingCondition
Typical MSH213L installationleft skew
Typical MSH213R installationright skew
13 1/4˝
1 5/8˝
1 3/4˝
5˝
MSH213L
MSH213L/R Skewed Truss Hanger
Back side withstraps bent over
AdditionalStrapping
for High Uplift
MP Framing Angle pg. 65
Bend over
Girder
Truss
LSTA Strap Tie pg. 73-74
Top view right shown
AdditionalStrapping
for High Uplift Back view shown
USP2173-111
Pla
ted
Tru
ss
1-800-328-5934 • www.USPconnectors.com 167
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®Severely Skewed Hangers – MSSH series
Floor Uplift1Floor Uplift1
Ref. No. Qty Type Qty Type Qty Type 100% 115% 125% 160% 100% 115% 125% 160%
face-max -- -- -- -- 22 10d 6 10d x 1-1/2 1770 1770 1770 730 1485 1485 1485 615
top-max 4 10d 6 10d 6 10d x 1-1/2 1735 1735 1735 730 1455 1455 1455 730
top-min 4 10d 2 10d 6 10d x 1-1/2 1240 1240 1240 -- -- 1040 1040 1040 -- --
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 3) Minimum nail penetration shall be 1-1/2˝ for 10d nails.
MSSH217LLeft shown attached
to web and top of chord
USP’s MSSH217 hanger accommodates a skew range of 60° to 85° (30° maximum offthe girder) without the need for a more expensive custom design hanger. Face nail towebs or bend the flange strap over the chord. Available in left (L) or right (R)configurations.
Materials: 18 gaugeFinish: G90 galvanizing
Installation:• Use all specified fasteners. See Product Notes, page 11.• The 3 lower holes on each strap are for top nailing when the strap is bent over thetruss chord. These holes are not for face nailing.• One or both straps may be bent over the bottom chord of the girder with top or backside nailing.• Note: Select the correct (right or left) hanger so that the strap on the outside of theangle will pass the end of the truss. When facing the hanger, the strap in the rear turnsin the direction of the skew. The front strap turns to pass behind the end of the carriedmember.• Attach the hanger at the end of the truss with a single 10d x 11⁄2˝ nail into the sideflange or bottom.• Place the truss in position against the girder. Push the outside strap past the end ofthe truss to the girder web and face nail through the top 8 holes with 10d x 11⁄2˝ nailsfor a 1 ply girder, or 10d common nails for multiple-ply girders.• The strap inside the angle can be formed over diagonal webs (if design allows) orbend over the girder chord. Use two nails into the top and/or back side of the girder.• If the outside strap does not contact a web, bend the strap tightly over thegirder chord. Use two nails into the top and/or back side of the girder.• For uplift resistance, other means of attachment are required. If both the truss andgirder have vertical webs, attach a scab to pack out the girder web nearly flush with thetruss web and use a field adjustable MP framing angle across the two. A top chord connection for uplift requires a flat LSTA strap tie wrapped under the girder and over thetruss chord.
Floor Floor
Ref. No. Qty Type Qty Type 100% 115% 125% 100% 115% 125%
8 10d per strap OR 1 Ply 1470 1690 1700 1195 1205 1215
4 10d top of bent straps 2 Ply 1700 1700 1700 1195 1205 1215
8 10d per strap OR 1 Ply 1470 1690 1700 1265 1455 15804 10d top of bent straps 2 Ply 1700 1700 1700 1550 1630 1700
1) No uplift value with this hanger. Use other hardware or nailing higher on carried member to counteract uplift. 2) One or both straps may be bent over bottom chord of girder with top or backside nailing. Note: The 3 lower holes on each strap are for top nailing when strap is bent. These holes are not for face nailing.
MSSH217L/R THASR/L218 18 Optional Construction: Parallel to Grain Loading in Hanger Seat
1 10d x 1-1/2
1 10d x 1-1/2
Roof
Girder Truss
Carrying Member
Hip
Carried Member CodeRef.
130
Fastener Schedule2
USPStock No.
SteelGauge
Roof
S-P-FDF-L / SP
Allowable Loads (Lbs.)1
GirderTruss
Bend over
Right shownbent over bottom chord
17 3/16˝
1 5/8˝1 3/4˝Optional
bottom nail
Pocket nail
3 holes fortop nailing
2 x 6 or 2 x 8
8 holes for face nailing
MSSH217Rright shown
MSSH217RRight shown
attached to webs
The SNP3 Skewed Nail Plate is designed and testedfor connecting square cut corner jack trusses atskews from 45˚ to 90˚.
Materials: 16 gaugeFinish: G90 galvanizingCodes: ESR-2104, FL820,
L.A. City RR 25745
Installation:• Install specified fasteners frombend line out from each end. Notall nail holes will be filled.• Attach to the supported truss onthe acute angle side so the SNP3runs behind the end of the jack.• Set jack truss against supporting truss and nail onexposed flange.• Bend angle only once.• 8d common nails may be substituted for 8d x 11/2˝nails with no reduction in load.
Pla
ted T
russ
1-800-328-5934 • www.USPconnectors.com168
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
Upift
Ref. No. Qty Type Qty Type 100% 115% 125% 160%
DF-L 530 530 530 530SP 530 530 530 530
S-P-F 445 445 445 445
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) 8d x 1-1/2˝ nails are 11 gauge (0.131˝ diameter) by 1-1/2˝ long.
USPStock No.
SteelGauge
WoodSpecies
8d x 1-1/2
Supporting Member
SNP3 TJC37 16 6
CodeRef.
8, F14,R9
Supported Member
Fastener Schedule2
8d x 1-1/2 6
Allowable Loads (Lbs.)1
3 3/8˝
3 1/2˝
3 1/2˝
Typical SNP3installation
SNP3
3 1/2˝
45˚to
90˚Max
SupportingTruss
3 1/2˝ SupportedTruss
Skewed Nail Plate – SNP3
Typical BN264installation
Nailing tabsadjust to fasten 22 1/2º mono trusses
USP2173-111
1-800-328-5934 • www.USPconnectors.com 169
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®Breakfast Nook Hangers – BN series
Pla
ted
Tru
ss
Floor Uplift1,5
Ref. No. L H B Qty Type Qty Type 100% 115% 125% 160%
BN264 -- -- 14 10 5-3/8 3-1/4 20 10d 2 10d x 1-1/2 2380 2735 2975 645
BN284 -- -- 14 10 7-1/8 3-1/4 20 10d 2 10d x 1-1/2 2380 2735 2975 645
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) Loading published for total load of connection. 3) Minimum nail penetration is 1-1/2˝ for 10d nails. 4) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 5) Maximum uplift per mono truss is 175 lbs. at 160% for DF-L/SP and 150 lbs. at 160% for S-P-F.
CodeRef.
11,F12
Dimensions
USPStock No.
SteelGauge
Roof
Carried Member
per Mono Truss
Fastener Schedule3,4
DF-L / SP
Carrying Member
Allowable Loads (Lbs.)2
Designed to carry four mono trusses in one connector, it reduces installation time andcost. Provides a tested, load rated connection. Standard configuration spacing:221/2°, 45°, 45°, 45°, 221/2°. The design also includes field adjustable nailing tabs.
Materials: 14 gaugeFinish: USP primerCodes: ESR-1465, FL817
Installation:• Use all specified fasteners. SeeProduct Notes, page 11.• Allow a 2˝ setback for each monotruss.• For pitched ceiling, design monotrusses with end-vertical upset. Upsetequals tangent of the ceiling slopetimes 5.6˝.• Bend tab only once.
22 1/2º 22 1/2º
45º
45º
45º
22 1/2º 22 1/2º
45º
45º
45º L
H
B
Field adjustablenailing tabswith slottedfastening holesfor slant nailing
BN264
BN264Standard configuration
(top view)
Hip/Jack Connectors – HHC, HJC, HJHC, & HTHJ series
HHC – Designed to support 1 ply hip and jack trusses/rafters. Contact USP whenusing in multi-ply applications.HJHC – Allows for hip / hip support and hip/ jack/hip installations. HJC & HTHJ – Used to simultaneously hang a combination of hips and jacks offgirder trusses. These hangers fit both left-hand and right-handapplications. An open back design allows for retrofit installations.
Materials: HHC, HJC, & HJHC – 12 gaugeHTHJ –18 gauge
Finish: G90 galvanizingOptions: See Specialty Options Chart on page 170.
Codes: ESR-1465, FL817, FL571, Dade County, FL 07-0214.20
Installation:• Use all specified fasteners. See Product Notes, page 11. Typical HJC/HTHJ
installation
continued on next page
Pla
ted T
russ
1-800-328-5934 • www.USPconnectors.com170
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
H
5 7/8˝ 5˝
HTHJ
H
3 1/4˝6˝
HJC
per Hip per Jack Floor Uplift1Floor Uplift1
Description Ref. No. H Qty Type Qty Qty Type 100% 115% 125% 160% 100% 115% 125% 160%
2 x 6 right / left HJC26 -- -- 12 5-3/8 16 16d 5 7 10d 2385 2740 2980 1840 2065 2375 2580 1545
2 x 8 right / left HJC28 -- -- 12 7-1/8 20 16d 6 8 10d 2980 3425 3505 1840 2580 2945 2945 1545
2 x 6 terminal HHC26 -- -- 12 5-7/16 20 16d 5 -- -- 10d 2980 3425 3505 1015 2580 2945 2945 1545
2 x 8 terminal HHC28 -- -- 12 7-3/16 24 16d 6 -- -- 10d 3505 3505 3505 1840 2945 2945 2945 1545 2 x 6 terminal HJHC26 MTHM 12 5-7/16 20 16d 5 2 10d 2980 3425 3505 1840 2580 2945 2945 1545
2 x 8 terminal HJHC28 -- -- 12 7-3/16 24 16d 6 2 10d 3505 3505 3505 1840 2945 2945 2945 1545 2 x 6 terminal HTHJ26-18 -- -- 18 5 16 16d 7 5 16d 2190 2520 2740 1790 1870 2155 2340 1505 11, F12
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) Loading published for total load of hip / jack connection. 3) Minimum nail penetration is 1-5/8˝ for 16d nails.
130
Carried Member
11, F6,F12, D3
Fastener Schedule
Carrying Member3
CodeRef.
USPStock No.
SteelGauge
Roof
Allowable Loads (Lbs.)2
DF-L / SP S-P-F
Roof
45º 45º 45º 45º
H
3 1/4˝9˝
H
3 1/4˝10 1/2˝
Typical HHCinstallation top view
Typical HJHCinstallation top view
HHC HJHC
H
3 1/4˝Varies8˝ max. width
HJC (skewed)Typical HJC (skewed) installation
with alternate skew angle top view
45º 45º
Typical HJC/HTHJ installation top view
Option Hip Truss Skew
Range 30˚ to 60˚
Allowable Loads 100% of table load
OrderingAdd SK, angle of hip
required, to product number.Ex. HJC26-SK55
HJC Specialty Options Chart
Specify angle(60° max)
Hip/Jack Connectors – HHC, HJC, HJHC, & HTHJ series cont.
Typical GT2T4Binstallation
USP2173-111
Pla
ted T
russ
1-800-328-5934 • www.USPconnectors.com 171
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®Girder Truss Hangers – GT, GTD, & GTS series
Uplift
Ref. No. Strap W1 L H D B Qty Qty Type 100% 115% 100% 115% 100% 115% 160%
DF-L / SP 1725 1985 2950 3390 3340 3840 2000
S-P-F 1515 1740 2515 2895 3085 3545 2000
DF-L / SP 2270 2610 3920 4510 5715 6575 2000
S-P-F 1980 2275 3330 3830 4850 5580 2000
DF-L / SP 2505 2880 4370 5025 4985 5730 2000
S-P-F 2175 2505 3710 4265 4590 5275 2000
DF-L / SP 3465 3985 5905 6790 6680 7680 2000
S-P-F 3040 3495 5040 5785 5485 5785 2000
DF-L / SP 5200 5980 8860 10190 10020 11520 2000
S-P-F 4560 5245 7560 8695 9260 9925 2000
DF-L / SP 6855 7885 11795 13565 13530 13870 2000
S-P-F 5995 6890 9630 9925 9630 9925 2000
DF-L / SP 6935 7975 11815 13585 13355 13870 2000
S-P-F 6080 6995 9630 9925 9630 9925 2000
DF-L / SP 2505 2880 4370 5025 4985 5730 2000
S-P-F 2175 2505 3710 4265 4590 5275 2000
DF-L / SP 3200 3675 5740 6605 8490 9765 2000
S-P-F 2745 3160 4830 5555 7160 8230 2000
DF-L / SP 3465 3985 5905 6790 6680 7680 2000
S-P-F 3040 3495 5040 5795 6175 7000 2000
DF-L / SP 4570 5255 7865 9045 11435 13150 2000
S-P-F 3995 4595 6685 7690 9720 11180 2000
DF-L / SP 5200 5980 8860 10190 10020 11520 2000
S-P-F 4560 5245 7560 8695 9260 10650 2000
DF-L / SP 6855 7885 11795 13565 14860 14860 2000
S-P-F 5995 6890 10030 11535 12480 12480 2000
DF-L / SP 6935 7975 11815 13585 13355 15360 2000
S-P-F 6080 6995 10080 11590 12350 13090 2000
DF-L / SP 9140 10515 15725 18085 19155 19465 2000
S-P-F 7990 9190 13370 13750 13455 13750 2000
DF-L / SP 3465 3985 5905 6790 6680 7680 2000
S-P-F 3040 3495 5040 5795 6175 7000 2000
DF-L / SP 4570 5255 7860 9040 11440 13155 2000
S-P-F 3995 4595 6685 7685 9720 11175 2000
DF-L / SP 5200 5980 8860 10185 10020 11525 2000
S-P-F 4560 5245 7560 8690 9260 10650 2000
DF-L / SP 6855 7880 11790 13560 14860 14860 2000
S-P-F 5990 6890 10025 11530 12480 12480 2000
DF-L / SP 6930 7970 11810 13580 13360 15365 2000
S-P-F 6080 6990 10080 11590 12345 13090 2000
DF-L / SP 9140 10510 15720 18080 19465 19465 2000
S-P-F 7990 9185 13365 15370 16350 16350 2000 1) Bolts shall conform to ASTM A 307 Grade A or better. 2) GT series require 2 x 6 vertical member for 2, 3, and 4 bolt hangers and 2 x 8 for 6 and 8 bolt hangers.
3/4
1
CodeRef.
130
10, F16,R14
10, F16,R14
3/4
1
3/4
1
3/4
1
3/4
1
12
3/4
1
3/4
3/4
3/4
1
3/4
3/4
1
12
12
12
12
12
12
12
12
12
12
12
12
8 16d
3 ply
GT3T8BH -- -- 3 7 5-1/8 7-1/4
12
25 9-1/4
26-1/4
9-1/4
9-1/4
3 7 5-1/8 7-1/4
6
6 9-1/4 6
4
86
16d -- -- 3 7 3-7/16 12
8 16d
6 16d
8 16d
8 16d
6
16d
16d
4 16d
3 16d
3 16d
12
3/4
1
6 16d
4 16d
4 16d
16d
12
12
12
16d
2 16d
4 16d
6 16d
2 16d
3
3-7/16
3-7/16
6
6
Steel Gauge
SupportedMember
USPStock No.
Dimensions
BackPlate
3 Ply
Supporting Member
Allowable Loads (Lbs.)
16d
Fastener Schedule1,2
Supporting Truss Supported Truss
BoltDia.
12
12
7-1/2
9-1/4
1 Ply 2 Ply
6
6
6
7-1/2
WoodSpecies
7-1/2
7-1/2
7
7
7-1/4
7-1/4
7-1/2
25
30-1/4
6
6
68-1/8
6
6
22
26-1/4
19
22-1/4
22
26-1/4
6-1/2
6-1/2
5-1/8
5-1/8
6-1/2
5-1/8
6
3-7/16
7
7-1/4
3-7/16
3-7/16
5-1/8
5-1/8
5-1/8
7-1/4
3-7/16 7-1/4
22
22-1/4
26-1/4
5-1/2
19
25
6
30-1/4 6
6
4-1/2
4-1/2
9-1/4
9-1/4
7
3
9-1/4
9-1/4
9-1/4
9-1/4
9-1/4
5-1/2
6-1/2
6-1/2
3 7
3
9-1/4
9-1/4
9-1/422
5-1/2
22-1/4 5-1/2
19
19
9-1/4
9-1/4
9-1/4
9-1/4
4-1/2
4-1/2
4-1/2
5-1/2
3 7
3
9-1/4
9-1/4
9-1/4
22
7
3 7
3 7
3 7
3 7
3
3 7
3 7
3 7
3 7
7
7
3 7
7
THGBH4
-- --
-- --
-- --
-- --
-- --
-- --
-- --
-- --
-- --
-- --
-- --
THGB3
-- --
THGBH3 GT3T8B
-- --
THGB2
THGBH2
-- --
GT4T8B
GT5T8BH
GT4T4B
GT4T4BH
GT4T6B
GT4T6BH
GT3T4B
GT3T4BH
GT3T6B
GT3T6BH
4 ply
5 ply
GT2T2B
GT2T2BH
GT2T3B
GT2T4B
GT2T6B
GT2T8B
GT3T3B
GT3T3BH
10, F16,R14
130
130
2 ply
GT2T6BH
3 7
3 7
3
The GT primarily hangs girder trusses off other girder trusses, although a wide varietyof other heavy-duty installations apply.
Materials: See chartFinish: USP primer
Options: All models available in LVL sizes, use M in place of T, as in GT2M4B.Codes: ESR-1831, FL822, L.A. City RR 25836
Installation:• Use all specified fasteners. See Product Notes, page 11.• Minimum heel height is 91/4˝ for GT hangers.
continued on next page
Pla
ted T
russ
1-800-328-5934 • www.USPconnectors.com172
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
Uplift
Ref. No. W1 W2 L H D B Qty Qty Type Qty Type 100% 115% 100% 115% 100% 115% 160%
DF-L / SP 1695 1945 2935 3375 3310 3810 2000
S-P-F 1480 1705 2495 2870 3055 3515 2000DF-L / SP 3385 3895 5870 6750 6625 7620 2000
S-P-F 2965 3410 4995 5745 6115 7035 2000DF-L / SP 2445 2815 4330 4980 4920 5660 -- --
S-P-F 2120 2440 3665 4215 4530 5210 -- --
DF-L / SP 3385 3890 5865 6745 6620 7610 -- --S-P-F 2960 3405 4990 5740 5765 5910 -- --
DF-L / SP 2445 2815 4330 4980 4920 5660 -- --
S-P-F 2120 2440 3665 4215 4530 5210 -- --
DF-L / SP 2460 2830 4355 5005 4950 5695 -- --
S-P-F 2135 2455 3685 4240 4555 5240 -- --
DF-L / SP 2450 2820 4335 4985 4930 5670 -- --
S-P-F 2125 2445 3670 4220 4535 5215 -- -- 1) The listed loads for GTS and GTD is the total of hip and jack connection. 2) Bolts shall conform to ASTM A 307 or better. GT Series require 2 x 6 vertical member for 2, 3, and 4 bolt hangers and 2 x 8 for 6 and 8 bolt hangers. All side pocket applications assume 45° angle. Must specify right or left for all GTS and GT skewed.**D is 3" for hip bucket.
130
CodeRef.
3/4
3/4
3/4
3/4
3/4
BoltDia.
2 ply skewed 45°
3 12 -- --16d -- --3/4
5
BackPlate
SteelGauge
SupportedMember
USPStock No.
Stra
p
9-1/4
9-1/4 12
3
4-1/2
4-1/27-1/4
6
4
10d x 1-1/25
3
5-1/2
5-1/2
5-1/2
4
3
5-1/2
3/4
10d x 1-1/2
4 10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
4
4
4
10d x 1-1/210d x 1-1/2 4
4 10d x 1-1/2
10d x 1-1/2
10d x 1-1/2
4
4
4
-- --
8
6
**4-1/2
**4-1/2
**4-1/2
**4-1/2
**4-1/2
45-1/2
9-1/4
9-1/4
1-5/8
3-7/16
1-5/8
3-7/16
-- --
-- --
1-5/8
22
22
22
3-7/16
3-7/16
1-5/8
1-5/8
1-5/8
1-5/8
1-5/83
7
7
7
7
7
7
7
2 Ply 3 Ply
3
19
19
22
199-1/4
-- --16d
3
2 ply hip & 1 ply jack
Supporting Member
Allowable Loads (Lbs.)1Dimensions Fastener Schedule2
SupportingTruss
Supported Truss Supported Hip
WoodSpecies
1 ply terminal hip
1 ply hip & jack
*GTS1T1H3BSKL/R
*GTS1T1H4BSKL/R
*GTS1T2H3BSKL/R
3
3 -- --
-- --
-- --
3
-- --
-- --
2 ply terminal hip
1 Ply
THMA
THMA-2
*GT2T2BSKL/R
*GT2T4BSKL/R
GTD1T1H3B
GTD1T2H3B
H
DW1
B
L
GTS1T2H3BSKLleft shown
GTD1T1H3B
GT series – Hip Applications
GT2T4B
Girder Truss Hangers – GT, GTD, & GTS series continued
W1 W1
45ºW2
W1
45º 45º
W2 W2
GT GTSleft shown
GTD
USP2173-111
Pla
ted
Tru
ss
1-800-328-5934 • www.USPconnectors.com 173
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®High Uplift Girder Truss Hangers – GTWS series
Uplift
Ref. No. W1 W2 L H D B Qty Qty Type Qty Type 100% 115% 100% 115% 100% 115% 160%
DF-L / SP 1695 1945 2935 3375 3310 3810 2000
S-P-F 1480 1705 2495 2870 3055 3515 2000DF-L / SP 3385 3895 5870 6750 6625 7620 2000
S-P-F 2965 3410 4995 5745 6115 7035 2000DF-L / SP 2445 2815 4330 4980 4920 5660 -- --
S-P-F 2120 2440 3665 4215 4530 5210 -- --
DF-L / SP 3385 3890 5865 6745 6620 7610 -- --S-P-F 2960 3405 4990 5740 5765 5910 -- --
DF-L / SP 2445 2815 4330 4980 4920 5660 -- --
S-P-F 2120 2440 3665 4215 4530 5210 -- --
DF-L / SP 2460 2830 4355 5005 4950 5695 -- --
S-P-F 2135 2455 3685 4240 4555 5240 -- --
DF-L / SP 2450 2820 4335 4985 4930 5670 -- --
S-P-F 2125 2445 3670 4220 4535 5215 -- -- 1) The listed loads for GTS and GTD is the total of hip and jack connection. 2) Bolts shall conform to ASTM A 307 or better. GT Series require 2 x 6 vertical member for 2, 3, and 4 bolt hangers and 2 x 8 for 6 and 8 bolt hangers. All side pocket applications assume 45° angle. Must specify right or left for all GTS and GT skewed.**D is 3" for hip bucket.
Stra
p
Typical GTWSinstallation
The GTWS series girder-to-girder hangers feature high uplift capacitiesalong with high gravity load ratings.
Materials: 10 gaugeFinish: G90 galvanizingCodes: FL6223
Installation• Use all specified fasteners. See Product Notes, page 11.• WS Wood Screws are included with hangers where specified.• GTWS2T shall be installed to a minimum 2x4 vertical member of a girdertruss with no restriction on the size of the bottom chord.• GTWS3T shall be installed to a minimum 2x6 vertical member of a girder truss with no restriction on the size of the bottom chord.• GTWS4T shall be installed to a minimum 2x8 vertical member of a girder truss with no restriction on the size of the bottom chord.
Uplift1
Ref. No. W H D Qty Qty 100% 115% 125% 160%
GTWS2T -- -- 10 3-1/4 16 4 22 WS3 16 WS3 2 Ply 8720 10030 10900 8435
GTWS3T -- -- 10 4-7/8 16 5 28 WS3 24 WS3 3 Ply 11100 12470 12470 12490
GTWS4T -- -- 10 6-1/2 16 5 28 WS3 24 WS3 4 Ply 11100 12470 12470 12490
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) WS3 wood screws require a minimum 3˝ wood penetration. 3) WS3 wood screws are 1/4˝ x 3˝ long and are included with the GTWS hangers. 4) WS3 wood screws may be installed in both vertical and horizontal members.
F26
USPStock No.
SteelGauge
Supported Truss
WoodScrews
WoodScrews
CodeRef.
No. ofPlys
Dimensions Fastener Schedule2,3,4 Allowable Loads (Lbs.)
Supporting Truss DF-L / SP
W4˝
16˝
GTWS2T
W5˝
16˝
GTWS3T
F1
Typical STCinstallation
W1
1 1/4˝ slots
W2
The STC provides uplift resistance by securing trusses to top plates.Slotted nail holes allow for horizontal movement as scissor trusses deflect.
Materials: 12 gaugeFinish: G90 galvanizingCodes: ESR-1465, FL817
Installation:• Use all specified fasteners. See Product Notes, page 11.• When installing, do not fully set nails.• Locate nails into the center of slots to allow for horizontal movement.
F1 Uplift1F1 Uplift1
Ref. No. Description W1 W2 Qty Type Qty Type 160% 160% 160% 160%
STC24 TC24 12 2 x 4 top plate 3-9/16 1-5/8 5 10d x 1-1/2 6 10d x 1-1/2 330 810 275 680
STC26 TC26 12 2 x 6 top plate 5-1/2 1-5/8 5 10d x 1-1/2 6 10d x 1-1/2 330 810 275 680 STC28 TC28 12 2 x 8 top plate 7-1/4 1-5/8 5 10d x 1-1/2 6 10d x 1-1/2 330 810 275 680
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long.
11,F12
Allowable Loads (Lbs.)
DF-L / SP S-P-F
CodeRef.
USPStock No.
SteelGauge
Dimensions Fastener Schedule2
Truss Plate
STC
Scissor Truss Clips – STC series
6 1/16˝
4 3/8˝2 1/16˝
3 1/16˝
FTC1F
7 5/8˝
4 3/8˝
2 1/16˝
3 1/16˝
FTC2F
Pla
ted T
russ
1-800-328-5934 • www.USPconnectors.com174
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
W1
1 1/8˝
H
W2
4 3/8˝
2˝
Ref. No. W1 W2 H Qty Type DF-L / SP S-P-F
3 x 2 FTC32 -- -- 18 2-1/16 2-1/2 1-1/2 10 10d x 1-1/2 680 590
FTC1 -- -- 18 3-1/2 3-1/16 1-1/2 10 10d 865 750 FTC1F -- -- 18 3-1/16 -- -- 4-3/8 10 10d 865 750
FTC2 -- -- 18 3-1/2 3-1/16 3 10 10d 865 750 FTC2F -- -- 18 3-1/16 -- -- 4-3/8 10 10d 865 750
1) Transfer loads are for 100% floor load, and shall not be increased for short term load duration. 2) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 3) Minimum nail penetration shall be 1-1/2˝ for 10d nails. 4) Truss designer shall determine the number of clips for concentrated loads and the spacing for uniform loads.
CodeRef.Truss Size
4 x 2
(2) 4 x 2
Dimensions Maximum Transfer Loads1,4USP
Stock No.Steel
Gauge
Fastener Schedule2,3
11,F12
Typical FTC 2 plymetal web truss installation
The FTC slides easily onto the top or bottom chord and provides aguide to help position and support the second truss during assembly.
Materials: 18 gaugeFinish: G90 galvanizingCodes: ESR-1465, FL817
Patents: #5,653,079
Installation:• Use all specified fasteners. See Product Notes, page 11.• The truss designer must determine the number of clips and spacing between units according to concentrated loadconditions and uniform loading requirements.
Concentrated Load Spacing Tips:Divide half of the concentrated load by the clip capacity to find the number of clips required.
Example:Concentrated (point) load = 3000 lbs, FTC capacity = 865 lbs
= 1.73 = 2 clips
Place 2 clips near concentrated load.
Uniform Load Spacing Tips:Divide the clip capacity by half the required load per lineal foot.
Example:Uniform (distributed) load = 500 lbs/ft, FTC1 Limited load = 865 lbs
= 3.46
Space clips at 3'4" along length of truss.
FTC
Floor Truss Clips – FTC series
Typical FTC2Fretrofit installation
Typical FTCinstallation
1⁄2 (3000lbs)
865lbs
8651⁄2 (500)
F1
F2
Typical SBP standardinstallation
USP2173-111
1-800-328-5934 • www.USPconnectors.com 175
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®Supplementary Bearing Plates – SBP series
Pla
ted
Tru
ss
100% 115% 125% 100% EBL 115% EBL 125% EBL
DF-L 625 2260 2600 2825 5540 5.91 5880 6.27 6105 6.51
SP 565 2440 2805 3050 5405 6.38 5770 6.81 6015 7.10 S-P-F 425 1940 2230 2425 4170 6.54 4460 7.00 4655 7.30
Hem Fir 405 1980 2275 2475 4105 6.76 4400 7.24 4600 7.57 DF-L 625 2320 2670 2900 8885 4.74 9235 4.93 9465 5.05
SP 565 2500 2875 3075 8435 4.98 8810 5.20 9010 5.32
S-P-F 425 2000 2300 2500 6465 5.07 6765 5.31 6965 5.46 Hem Fir 405 2040 2345 2550 6295 5.18 6600 5.43 6805 5.60
DF-L 625 2320 2670 2900 12165 4.33 12515 4.45 12745 4.53 SP 565 2500 2875 3075 11400 4.48 11775 4.63 11975 4.71
S-P-F 425 2000 2300 2500 8695 4.55 8995 4.70 9195 4.81
Hem Fir 405 2040 2345 2550 8420 4.62 8725 4.79 8930 4.90 DF-L 625 2320 2670 2900 15445 4.12 15795 4.21 16025 4.27
SP 565 2500 2875 3075 14365 4.24 14740 4.35 14940 4.41 S-P-F 425 2000 2300 2500 10925 4.28 11225 4.40 11425 4.48
Hem Fir 405 2040 2345 2550 10545 4.34 10850 4.47 11055 4.55
DF-L 625 3165 3640 3955 8320 8.87 8795 9.38 9110 9.72
SP 565 3415 3930 4270 8075 9.53 8590 10.14 8930 10.54 S-P-F 425 2715 3125 3395 6220 9.76 6630 10.40 6900 10.82
Hem Fir 405 2770 3190 3465 6110 10.06 6530 10.75 6805 11.20
DF-L 625 3250 3735 4060 13565 7.23 14050 7.49 14375 7.67 SP 565 3500 4025 4375 12825 7.57 13350 7.88 13700 8.08
S-P-F 425 2800 3220 3500 9815 7.70 10235 8.03 10515 8.25 Hem Fir 405 2855 3285 3570 9540 7.85 9970 8.21 10255 8.44
DF-L 625 3250 3735 4060 18720 6.66 19205 6.83 19530 6.94 SP 565 3500 4025 4375 17485 6.88 18010 7.08 18360 7.22
S-P-F 425 2800 3220 3500 13320 6.96 13740 7.18 14020 7.33
Hem Fir 405 2855 3285 3570 12880 7.07 13310 7.30 13595 7.46 DF-L 625 3250 3735 4060 23875 6.37 24360 6.50 24685 6.58
SP 565 3500 4025 4375 22145 6.53 22670 6.69 23020 6.79 S-P-F 425 2800 3220 3500 16825 6.60 17245 6.76 17525 6.87
Hem Fir 405 2855 3285 3570 16220 6.67 16650 6.85 16935 6.97
1) Allowable loads are for a pair of SBP devices. SBP's shall be installed in pairs. 2) Multiple ply trusses shall be fastened together to act as a single unit. 3) EBL denotes effective bearing length and includes the actual bearing length plus the contribution of the SBP device. 4) Assumes full seating of truss on top plate.
SBP6 on 2 x 6 Top Plate (5-1/2˝ wide)
4 Ply
1 Ply
2 Ply
3 Ply
4 Ply
1 Ply
2 Ply
3 Ply
SBP's Alone SBP + Truss Bearing4
Allowable Loads (Lbs.)1,2,3
SBP4 on 2 x 4 Top Plate (3-1/2˝ wide)
No. ofTrussPlys
WoodSpecies
Fc
(psi)
W L
D
H
SBP
Use the SBP instead of extra truss plys or nail-on scabs to distributeconcentrated truss reactions and avoid top plate crushing. The two-piece design accommodates any number of girder plys. Awraparound design gives superior uplift resistance, and reinforcementribs effectively distribute bearing loads. Works with both single anddouble 2x4 or 2x6 top plates.
Materials: 16 gaugeFinish: G90 galvanizingCodes: ESR-1831, FL822, L.A. City RR 25836
Installation:• Use all specified fasteners. See Product Notes, page 11.• The SBP shall be installed in pairs.
F1 F2 Uplift5F1 F2 Uplift5
Ref. No. W H L D Qty Type Qty Type Qty Type 160% 160% 160% 160% 160% 160%
2-7/8˝ or less 20 10dx1-1/2 1390 1630 1295 1170 1370 10853˝ or more 20 10d 1390 1630 1295 1170 1370 1085
2-7/8˝ or less 28 10dx1-1/2 1390 1630 1295 1170 1370 1085
3˝ or more 28 10d 1390 1630 1295 1170 1370 1085
1) Fastener Schedule is for a pair of SBP devices. 2) Allowable loads are for a pair of SBP devices. SBP's shall be installed in pairs. 3) Multiple ply trusses shall be fastened together to act as a single unit. 4) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) x 1-1/2˝ long. 5) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted.
10d
10d
8
8
16
16
2 1
2 1
3-1/2 3-1/4
5-1/2 3-1/4
SBP4 TBE4
SBP6 TBE6
USPStockNo.
SteelGauge
Dimensions
JoistThickness
Fastener Schedule1,4
DF-L / SP S-P-F
Allowable Loads (Lbs.)2,3
10,F16,R14
Top Sides
Truss
CodeRef.
Plate
4 10d
4 10d
W
L
D
H
SBP tab up
Typical SBP alternateinstallation
2˝
1 1/4˝
2 3/4˝
TR1
Pla
ted T
russ
1-800-328-5934 • www.USPconnectors.com176
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
F1
F2
Typical TR2 installation
Typical HTC4installation
F1 F2 F1 F2
Ref. No. Description Qty Type Qty Type 160% 160% 160% 160%
TR1 STC 18 single slot 1 8d 2 8d 85 50 35 35
TR2 DTC 18 double slot 2 8d 4 8d 125 210 85 135
1) Loads have been increased for short-term loading; no further increase allowed. 2) Truss must be bearing on top plate to achieve the allowable loads under "Without Gap". 3) Installed with maximum 1/4˝ space between rafter or truss and top plate under "With 1/4˝ Gap". Space is not limited to 1/4˝, where loads are not required.
Fastener Schedule Allowable Loads (Lbs.)1
Without Gap2 With 1/4˝ Gap 3
DF-L / SPTruss Plate
CodeRef.
130
USPStock No.
SteelGauge
W
H
D
ZC2
Blocking Supports – ZC series
ZC clips secure blocking between joists or trusses whichprovides support for drywall or sheathing.
Materials: See chartFinish: G90 galvanizingCodes: ESR-1465, FL817
Installation:• Use all specified fasteners. See Product Notes, page 11.
ZC4
Allowable Load (Lbs.)2
DF-L / SP
Downward
Ref. No. W H D Qty Type Qty Type 100%
ZC2 Z2 20 2-1/4 1-9/16 1-1/2 3 10d x 1-1/2 2 10d x 1-1/2 240 11, F12 ZC4 Z4 12 1-1/2 3-9/16 1-3/8 2 10d x 1-1/2 1 10d x 1-1/2 420 11, F12
ZC24 Z28 28 2-1/2 1-9/16 1-3/8 -- -- 120 ZC34 Z38 28 2-1/2 2-9/16 1-5/16 -- -- 120
1) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 2) Allowable load shall not be increased for other load duration factors.
CodeRef.
SteelGauge
USPStock No.
Dimensions Fastener Schedule1
Header Blocking
10d x 1-1/2 10d x 1-1/210d x 1-1/2 10d x 1-1/2
Slotted design allows truss to deflect without imposingload on wall below.
Materials: See chartFinish: G90 galvanizing
Installation:• Use all specified fasteners. See Product Notes, page 11.• Do not fully set nails.• Locate nails into the center of slots.
Slotted design allows truss to deflect without imposing load on wall below.
Materials: 16 gaugeFinish: G90 galvanizing
Installation:• Use all specified fasteners. See Product Notes, page 11.• Do not fully set nails.
Typical ZC installation
Roof Truss Ties – TR series
Heavy Truss Deflection Clip – HTC4
F1
F2
1 7/8˝
2 1/2˝
2 11/16˝
HTC4
TR2
Top Side
Ref. No. Qty Qty Type Qty Type F1 F2 F1 F2
HTC4 HTC4 16 2 4 10d x 1-1/2 3 10d x 1-1/2 255 525 55 295 110
1) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 2) Loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 3) Truss/Rafter must be bearing on top plate to achieve the allowable loads under "Without Gap". 4) When installed with maximum 1-1/4" space between truss/rafter and top plate, use loads under "With 1-1/4" Gap".
CodeRef.
USPStock No.
SteelGauge
Fastener Schedule1 Allowable Loads (Lbs.) 2
Without Gap3 With 1-1/4˝ Gap4
DF-L / SP (160%)Plate Truss/Rafter
3 1/2˝
3 1/4˝
1 15/16˝
1˝
USP2173-111
Pla
ted
Tru
ss
1-800-328-5934 • www.USPconnectors.com 177
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®Truss Field Splice Kits – FS & FSS series
Typical FSS installation
Typical FS installation
Job site splicing of long trusses is made easier with Truss Field SpliceKits. The FS and FSS (for scissors trusses) includes a pair of plates,bolts, nuts, and a Splice Clip for top chord alignment. Allowable loads aresometimes limited by tension in the net section of the wood. Choose thebottom chord size and species that will satisfy the tension requirement.Analyze tension in the web to determine the required size.
Materials: FS & FSS – See chart, bolts, and nuts includedSplice Clip – 12 gauge
Finish: FS & FSS – USP primer;Splice Clip – G90 galvanizing;Bolts – zinc plating
Installation:• Use all specified fasteners. See Product Notes, page 11.• Position the two trusses, center one splice plate on the bottom chordsand clamp in place for a drilling template. Install the Splice Clip at the toptruss plate and fasten with (18) 10d x 11⁄2˝ nails. Drill through the bottomchord using splice plate as a template. Place splice plate on each sideand bolt the connection firmly.
Splice Clip
FSS
FS
Allowable Loads (Lbs.)1
DF-L SP S-P-F
Ref. No. Qty Type 115% 115% 115%
2 x 6 4995 4845 39102 x 8 6695 6305 5240
2 x 10 7195 7565 60302 x 6 4995 4845 3910
2 x 8 6695 6305 5240
2 x 10 8320 7565 65102 x 6 9995 9690 7820
2 x 8 13390 12615 10480
2 x 10 14130 14725 121402 x 6 9995 9690 7820
2 x 8 13390 12615 104802 x 10 16640 15125 13020
2 x 6 14120 14540 11730
2 x 8 14145 14740 130702 x 10 14130 14725 13075
2 x 6 14990 14540 117302 x 8 20085 18920 15720
2 x 10 21770 22670 19530
2 x 6 4995 4845 39102 x 8 6695 6305 5240
2 x 10 7195 7565 60302 x 6 4995 4845 3910
2 x 8 6695 6305 5240
2 x 10 8320 7565 65102 x 6 9995 9690 7820
2 x 8 13390 12615 10480
2 x 10 14130 14725 121402 x 6 9995 9690 7820
2 x 8 13390 12615 104802 x 10 16640 15125 13020
1) Allowable loads shall not be increased for other load duration factors. 2) Allowable loads are based on the lesser of the calculated bolt loads and the calculated wood tensile strength at the critical net section. 3) Wood tensile strengths are based on the Ft of 450 psi for S-P-F, 575 psi for DF-L, and approximately 540 psi for SP; and increased by the size factors in accordance with the NDS®.
3/4˝ x 3˝
3/4˝ x 5˝
3/4˝ x 5˝
3/4˝ x 5˝
3/4˝ x 7˝
3/4˝ x 7˝
3/4˝ x 3˝
Bolt Schedule
3/4˝ x 3˝
3/4˝ x 3˝
3/4˝ x 5˝
8 FS8B
FS12B
FS8B-2
FS12B-2
FS8B-3
FS12B-3
FSS8B
FSS12B
FSS8B-2
FSS12B-2
-- --
-- --
-- --
-- --
-- --
-- --
-- --
-- --
-- --
-- --
7 1
7 2
7 3
7 1
2
3 1 12
3 2 18
12
3 1 18
3 3 12
8
3 12
130
USPStock No.
SteelGauge
TrussPlies
CodeRef.
ChordSize
7 2 12
8
Pla
ted T
russ
1-800-328-5934 • www.USPconnectors.com178
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
Flap22 1/2˝
7/8˝1˝
1 3/8˝
Top view
End view
Temporary ConstructionBracing Installation
OddSpacing
24 o.c.
The Stabilizer™ Truss Brace & Spacer provides temporary construction bracing in the roofand ceiling planes, as well as permanent lateral bracing for webs as specified by your trussengineering.
The Stabilizer™ is easily installed by embedding the patented MII 20 teeth on the topflange straight into the edge of the truss member to be braced with a framing hammer. Theside tabs are then secured by driving the teeth into the face of the truss member beingbraced.
Materials: 20 gaugeFinish: G60 galvanizingCodes: ESR-2362
Installation:• Use The Stabilizer™ for standard 24˝ o.c. spacing. For odd spacing, cut and insert a solidblock between the trusses.• Typically, The Stabilizer™ is installed at 6´– 8´ centers along the roof plane and 10´– 15´along the ceiling plane. (Refer to engineering specifications BCSI 1-03, published by TheTruss Plate Institute for specific bracing requirements.)• The Stabilizer™ must be supplemented with diagonal bracing in the roof and ceilingplanes and cross bracing in the web plane at required intervals.• Web forces are not to exceed 8000 lbs.• The Stabilizer™ is properly installed when the top flap and side tabs are flush with themember being braced. 25 1/4˝
ST24H Stabilizer™
Hammer here
Hammer here
Web bracinginstallation
Chordattachment detail
Important: The erection contractor is responsible for determining andinstalling the temporary bracing for the structure, including the trusses. It ismost important for the installer to provide adequate means for bracing the firsttruss installed. The performance of the entire bracing system depends on theadequacy of the ground bracing or other means of bracing the first group oftrusses installed. The building designer is responsible for the permanent bracing design of the overall structure including the truss. This includes thedesign of required supplemental diagonal and cross bracing.
Ref. No. Tension Compression
ST24H TSB2-24 20 24˝ 105 155 420
1) 1 pound = 4.448N 2) Fastener shall be (1) 8d or 10d common wire nail inserted through nail slot.
USPStock No.
SteelGauge
O.C.Spacing
Allowable Axial Loads (Lbs.)
Tensionwith Fastener
1˝
1 3/8˝
7/8˝
1 3/8˝
1 1/2˝1/4˝
1 1/2˝
1 3/8˝
Standard Mil 20 punch
Tab
71.28º
Side view
Truss Brace & Spacer (Stabilizer™) – ST24H
TSX multi-unit spacer
USP2173-111
Pla
ted
Tru
ss
1-800-328-5934 • www.USPconnectors.com 179
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®Truss Spacers – TS & TSX series
Transfers lateral loads from girder truss into bearing walls.
Materials: See chartFinish: USP primerCodes: ESR-1465, FL817
Installation:• Use all specified fasteners. See Product Notes, page 11.• WS3 Wood Screw, 1/4˝ dia. x 3˝ long, are supplied withDSC4 connector.
10 1/2˝
2 1/8˝
2˝
7˝
Drag Strut Connector – LDSC & DSC series
Ref. No.
1-1/4 TS -- -- 20 24˝ 2' 1-1/2˝ 1
1-1/2 TSX24 TSF2-24 22 24˝ 10' 5
1) TSX spacers are shipped folded.
120
CodeRef.
JoistWidth
SectionsPer Piece
USPStock No.1
SteelGauge
O. C.Spacing
OverallLength
TS single-unit spacer
Typical TSX installation
Important: These units provide spacing guidesonly. Do not rely on the TS or TSX for bracing.
21˝ 3 1/4˝3˝
DSC4R right shown
LDSC4L left shownTypical DSC4R
installation
Truss spacers give framers fast and accurate spacing for trusses, rafters, or floorjoists. The TS and TSX eliminate the need to mark layouts on bearing plates,improve installation speed, and help eliminate spacing errors. These spacers arelight weight and compact.
Materials: See chart
Installation:• Use (1) 8d nail per end to fasten units to trusses, rafters, or floor joists.
Compression Tension Compression Tension
Ref. No. Qty Type Qty Type 160% 160% 160% 160%
LDSC4L/R -- -- 14 9 10d x 1-1/2 9 10d x 1-1/2 1640 1640 1425 1425
DSC4L/R DSC5R/L-SDS3 3 16 WS3 16 WS3 4965 4945 4270 4250
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) WS3 wood screws are 1/4˝ x 3˝ and are included with DSC4 connector. 3) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long.
11,F12
CodeRef.
USPStock No.
SteelGauge
Allowable Tension Loads (Lbs.)1
DF-L / SP S-P-F
Fastener Schedule2,3
Truss Top Plate
Pla
ted T
russ
1-800-328-5934 • www.USPconnectors.com180
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
• Wood blocking should be of similarsize/grade as the truss member to which it isattached. The blocking should be designed toact as one unit with truss members.• Truss designer shall approve blockingsize/grade, fasteners required, and application.• All fasteners used to attach wood blocking should be independent of the fasteners in the truss hanger.
THDH26-2pg. 153
Filler Blocking
GT4T6BHpg. 160
Filler Blocking
THDH28-2pg. 153
Filler blockinstallation
Wood filler blocking used forsupported member width less
than hanger width.
(Blocking and blocking fasteners/quantity to be
designed by truss designer orengineer of record)
Panel pointinstallation
Connection with face mount hangerattaching to a truss panel point.
(Hanger nails that do not penetrate woodin panel point provide no
load resistance)
Reduce load according to the code.
Backer blockinstallation
Wood blocking used to achieve full designload value of a face mount hanger attached to
a carrying member.
(Blocking to be designed by trussdesigner or engineer of record)
Wood blocking
JUS26 pg. 89
Alternate Installations
USP2173-111
Bridging – N & O seriesM
iscella
neou
s
181
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
W
L
N
12˝ 16˝ 19.2˝ 24˝ 30˝ 32˝ 36˝ 42˝ 48˝
7-1/4 -- --N16/O16
/O40-- -- -- -- -- -- -- -- -- -- -- -- -- --
9-1/4 N16N16/O16
/O40N27 N27/N30 N36 N36/N42 N42 N48 N54/N56
9-1/2 N16 N16 N27 N27/N30 N36 N36/N42 N42 N48 N54/N56
10 N16 N16 N27 N27/N30 N36 N36/N42 N42 N48 N54/N5611-1/4 N16 N16 N27 N30 N36 N36/N42 N42 N48 N54/N56
11-7/8 N16 N27 N27 N30 N36 N36/N42 N42 N48 N54/N56
12 N16 N27 N27 N30 N36 N36/N42 N42 N48 N54/N5614 N16 N27 N27/N30 N30 N36/N42 N36/N42 N42 N48 N54/N56
16 N27 N27 N27/N30 N30 N36/N42 N42 N42/N48 N48/N54 N54/N56
18 N27 N27/N30 N30 N36 N36/N42 N42 N42/N48 N48/N54 N54/N5620 N27/N30 N27/N30 N30 N36 N42 N42 N42/N48 N48/N54 N54/N56/N60
22 N27/N30 N30 N36 N36/N42 N42 N42/N48 N48 N54/N56 N54/N56/N6024 N30 N36 N36 N36/N42 N42 N42/N48 N48 N54/N56 N56/N60
26 N30/N36 N36 N36/N42 N42 N42/N48 N48 N48/N54 N54/N56 N56/N60
28 N36 N36/N42 N36/N42 N42 N42/N48 N48 N48/N54 N54/N56 N6030 N36/N42 N36/N42 N42 N42/N48 N48 N48 N48/N54/N56 N54/N56/N60 N60
32 N36/N42 N42 N42 N42/N48 N48 N48/N54 N54/N56 N54/N56/N60 N60
All models require (2) 8d x 1-1/2 nails at each end. 1) Based on 1-1/2˝ joist. Consult USP for suitable product for wider joists.
Sized for Joist-to-Joist X Bridging
Joist Spacing1
I-BeamHeight
O – The O series spans three joists in under/over installation. Prong teeth in the center help reduce nailing.
N – The N series spans two joists per unit. Can be used for bridging or bracing I-Joists.See chart.
Materials: See chartFinish: G90 galvanizingCodes: ESR-1781, L. A. City RR 25843, FL13285
Installation:• Use specified fasteners in models with fastener requirements.• For all models – Bridging should be installed on floor joists with a nominal depth-to-thickness ratio of 5 to 6 or more (2005 National Design Specification for WoodConstruction; Section 4.4.1). Bridging units should be installed in pairs at intervals of8´ or less. Bridging pairs should form an “X” between joists; leave a slight spacebetween the units to avoid noise-generating contact. Follow specific installation instructions below for particular models.• Install prior to subfloor sheathing. Use (2) 8d x 11⁄2˝ nails at each end. Fully seat nailsto avoid any movement against the bridging and subsequent floor noise.
Typical Oinstallation
W
L
O
Typical Ninstallation
Ref. No. W L Qty Type
N16 LTB20, TB20 22 3/4 19-3/4 4 8d x 1-1/2 16 N27 TB27 20 3/4 26-13/16 4 8d x 1-1/2 -- --
N30 TB30 20 3/4 29-13/16 4 8d x 1-1/2 -- --
N36 TB36 20 3/4 35-13/16 4 8d x 1-1/2 -- -- N42 TB42 20 3/4 42 4 8d x 1-1/2 -- --
N48 TB48 20 3/4 48 4 8d x 1-1/2 -- -- N54 TB54 20 3/4 54 4 8d x 1-1/2 -- --
N56 TB56 20 1 56 4 8d x 1-1/2 -- -- N60 TB60 20 1 60 4 8d x 1-1/2 -- --
O16 -- -- 18 1 44 4 8d x 1-1/2 16 120
O40 LTB40 22 3/4 39-3/4 4 8d x 1-1/2 16 5, F30, R5
1) 8d x 1-1/2 nails are 11 gauge (0.131˝ diameter) by 1-1/2˝ long. 2) For joist spacing, refer to the Joist Installation chart. 3) Joist spacing is based on a 1-1/2˝ joist. Consult USP regarding wider joist applications.
5,F30,R5
JoistSpacing O.C.
DimensionsUSP
Stock No.Steel
Gauge
Fastener Schedule1
CodeRef.
Joist Installations
1-800-328-5934 • www.USPconnectors.com
Mis
cell
an
eou
s
1-800-328-5934 • www.USPconnectors.com182
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
Typical MBG installation
Step 1Step 2
Bridging – MB16 & MBG series
W
L
MBG
MBG – Grip tooth bridging. Features special teeth which grip joists and provide easy sin-gle-nail installation. Can be installed after subfloor is in place.
MB16 – Snap-on, no-nail bridging can be placed in existing floor systems where joistmovement is suspected. Two-piece construction creates a solid diagonal brace againstjoist movement.
Materials: See chartFinish: G90 galvanizingCodes: ESR-1781, L. A. City RR 25843, FL13285
Installation:• Use specified fasteners in models with fastener requirements.• For all models – Bridging should be installed on floor joists with a nominal depth-to-thickness ratio of 5 to 6 or more (2005 National Design Specification for WoodConstruction; Section 4.4.1). Bridging units should be installed in pairs at intervals of 8´orless. Bridging pairs should form an “X” between joists; leave a slight space between theunits to avoid noise-generating contact. Follow specific installation instructions below for particular models.• MBG – May be installed before or after sheathing. Position the unbent end of the bridg-ing unit near the top of the joist and drive prongs into wood with a hammer blow to theheel of the bent end. Wedge bent end near the lower edge of the opposite joist, set teethinto wood with hammer blow. Nail holes are provided at the bent end if prongs are dam-aged during installation. Fully seat nails to avoid any movement against the bridging andsubsequent floor noise.• MB16 – Two-piece unit is shipped as one piece. Bend unit in center up and down tobreak into two pieces. Slide narrower piece inside wider piece, setting the end tab intoslot appropriate for joist spacing. Setting one prong end near the top of one joist and theopposite prong end near the bottom of the opposite joist, pull down on the center of thebridging until the wider piece snaps into place over the narrow piece and creates a rigid,one-piece bridging unit. Wear gloves during installation.
MB16
Typical MB16installation
Joist Size Ref. No. W L Qty Type
2 x 8 12 MBG812 NCA2X8-12 22 15/16 11-3/4 1 8d x 1-1/2 2 x 10 12 MBG1012 NCA2X10-12 22 15/16 12-3/4 1 8d x 1-1/2
2 x 12 12 MBG1212 NCA2X12-12 22 15/16 14 1 8d x 1-1/2
2 x 14 12 MBG1412 -- -- 22 15/16 16 1 8d x 1-1/2 2 x 16 12 MBG1612 -- -- 22 15/16 17 1 8d x 1-1/2
2 x 8 - 10 - 12 16 MB16 -- -- 22 11/16 -- -- -- -- -- -- 2 x 8 16 MBG816 NCA2X8-16 22 15/16 15-9/16 1 8d x 1-1/2
2 x 10 16 MBG1016 NCA2X10-16 22 15/16 16-5/16 1 8d x 1-1/2
2 x 12 16 MBG1216 NCA2X12-16 22 15/16 17-1/4 1 8d x 1-1/2 2 x 14 16 MBG1416 -- -- 22 15/16 18-7/16 1 8d x 1-1/2
2 x 16 16 MBG1616 -- -- 22 15/16 19-5/8 1 8d x 1-1/2
2 x 8 24 MBG824 -- -- 22 1-5/16 23-1/2 1 8d x 1-1/2 2 x 10 24 MBG1024 -- -- 22 1-5/16 24 1 8d x 1-1/2
2 x 12 24 MBG1224 -- -- 22 1-5/16 24-3/4 1 8d x 1-1/2 2 x 14 24 MBG1424 -- -- 22 1-5/16 25-5/8 1 8d x 1-1/2
2 x 16 24 MBG1624 -- -- 22 15/16 26-5/8 1 8d x 1-1/2
1) 8d x 1-1/2 nails are 11 gauge (0.131˝ diameter) by 1-1/2˝ long. 2) Joist spacing is based on a 1-1/2˝ joist, consult USP regarding wider joist applications.
5,F30,R5
Joist
Spacing O.C.2
DimensionsUSPStock No.
SteelGauge
CodeRef.
Fastener Schedule1
USP2173-111
Mis
cella
neou
s
1-800-328-5934 • www.USPconnectors.com 183
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
Typical ICPL516-TZinstallation
Typical KNS1 & PL4installation
W
H
Ref. No. W H Qty Type
ICPL58 PSPN58, S/PSPN58 1/16 8-1/16 5 4 8d or prongs
PL4 NS2, NSP2 1/16 2 5 -- -- prongs KNS1 NS1, NSP1 1/16 1-1/2 3 -- -- prongs
CodeRef.
100
DimensionsUSPStock No.
SteelThickness
Fastener Schedule1
W
H
KNS1
ICPL58
PL4
WH
Typical ICPL58installation
DF-L / SP S-P-F
Ref. No. W H Qty Type 160% 160%
Sill Plate 12 16d HDG + prongs 1355 1160
Double Top Plate 16 16d HDG + prongs 1805 1550
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted. 2) Minimum nail penetration shall be 1-5/8˝ for 16d nails.
Allowable Loads1Dimensions Fastener Schedule2
5
CodeRef.
100
USPStock No.
SteelThickness
InstallationType
ICPL516-TZ PSPN516, PSPN516Z, S/PSPN516, S/PSPN516Z
1/16 16-1/4
H
W
ICPL516-TZ
Protection Plates – ICPL series, KNS1, & PL4
Easy-to-install plates protect plumbing andpower/communication wiring from nail or screw penetration.
ICPL58 – Installs with nails.
KNS1 & PL4 – Prongs allow for quick installation.
Materials: 16 gaugeFinish: ICPL516-TZ – G-185 galvanizing;
All other – GalvanizedOptions: ICPL58 is available in Triple Zinc.
To order, add TZ, to stock number, as in ICPL58-TZ.
Installation:• Use all specified fasteners. See Product Notes,page 11.• 16 gauge steel conforms to protection shield platerequirements of the National Electrical Code andInternational Plumbing Code.
Mis
cell
an
eou
s
1-800-328-5934 • www.USPconnectors.com184
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
Ref. No. W1 W2 L Qty Type Qty Type
RWB96 WB106C 16 1-1/4˝ -- -- 9' 6˝ 15 8' 60° 4 8d 1 8d RWB114 WB126C 16 1-1/4˝ -- -- 11' 4-3/8˝ 12 8' 45° 4 8d 1 8d
RWB143 WB143C 16 1-1/4˝ -- -- 14' 3˝ 10 10' 45° 4 8d 1 8d WBC10 CWB106, RCWB10 18 7/8˝ 1˝ 9' 5-3/4˝ -- -- 8' 60° 2 16d 1 8d
WBC12 CWB126, RCWB12 18 7/8˝ 1˝ 11' 4-3/8˝ -- -- 8' 45° 2 16d 1 8d
WBT10 TWB10 22 1-3/8˝ -- -- 9' 3˝ -- -- 8' 60° 4 8d 1 8d WBT12 TWB12 22 1-3/8˝ -- -- 11' 4˝ -- -- 8' 45° 2 8d 1 8d
WBT14 RCWB14, TWB14 22 1-3/8˝ -- -- 14' 2˝ -- -- 10' 45° 2 8d 1 8d
WB106 WB106 16 1-1/4˝ -- -- 9' 5-1/2˝ -- -- 8' 60° 3 16d 1 8d WB126 WB126 16 1-1/4˝ -- -- 11' 4-1/4˝ -- -- 8' 45° 3 16d 1 8d
1) These products substitute for code prescribed 1 x 4 let-in bracing. 2) Minimum nail penetration shall be 1-5/16˝ for 8d nails and 1-5/8˝ for 16d nails.
USP
Stock No.1Steel
GaugePieces
Per RollWall
Height
Dimensions
Each Plate Each StudInstallAngle
CodeRef.
5, F30, R5
Fastener Schedule2
10,F16, R14
Wall Bracing – RWB, WB, WBC, & WBT series
RWB pre-embossedsnap-off points
W1
L
W2
W1
L
RWB – Flat bracing conveniently packaged in a handy roll out dispenser. Perfect forunexpected job site shortages. The 35-pound dispenser pack fits easily into a truck bedfor transport. Pre-embossed snap-off points can be broken off by hand (wear gloves forsafety).WB – A flat style bracing engineered to easily nail to studs. No cutting or fitting needed.
WBC – The L-shaped design for additional strength and rigidity.
WBT – Rolled edges and T-style design gives the WBT strength, rigidity, andeliminates sharp, sheared edges.
Materials: See chartFinish: G90 galvanizingCodes: ESR-1831, ESR-1781, FL822, FL13285,
L.A. City RR 25836, L.A. City RR 25843
Installation:• Use all specified fasteners. See Product Notes, page 11.• Bracing is a framing aid, not a substitute for structural shearwall components.• RWB & WB – Use with 16˝ or 24˝ o.c. studs. Install in pairs forming an “X” oropposing “V” at each end of a maximum 25-foot long wall panel.
Steps: Square the panel. Straighten any kinks in bracing caused by handling. Lay bracing on the panel flush to the top of top plate and flush to the bottom of the bottom plate. Secure bracing to the top plate and bottom plate using 16d nails (WB) or 8d nails (RWB). Position second bracing at an angle opposite to the first brace to form an “X” and secure to top and bottom plate as with the first bracing. Using 8d nails, secure bracing to all intersecting studs.
• WBC & WBT – Use with 16˝ o.c. studs. Install one brace at each end of wallsection, not exceeding 25 feet, in an opposing “V” pattern. Use a length of the bracingas a straight web to mark studs. Cut a saw kerf 5⁄8˝ deep (1˝ deep for WBC). Insert thebracing web into the saw kerf, and drive one nail into the top plate. Raise the wall section into place and plumb. Finish fastening according to the nail schedule.
Typical RWB, WBinstallation
WB
Typical WBC/WBTinstallation
WBC
W1
9/16˝
L
WBT
Stud shoes reinforce joists, plates, studs, or rafters whichhave been drilled or notched during construction.
Materials: 16 gaugeFinish: G90 galvanizing
Installation:• Use all specified fasteners. See Product Notes, page 11.• STS units are not structurally rated and should notbe used as a total member replacement in structural applications.• For use with 2˝ O.D. pipe.
USP2173-111
1-800-328-5934 • www.USPconnectors.com 185
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
Typical STS1installation
Typical SFP30installation
30˝
Dimension
Ref. No. Description W Qty Type
STS1 SS1.5 16 Single Stud 1-9/16 10 10d x 1-1/2
STS2 SS3 16 Double Stud 3-1/16 12 10d STS3 SS4.5 16 Triple Stud 4-9/16 14 10d
1) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) and 1-1/2˝ long. 2) Minimum nail penetration shall be 1-1/2˝ for 10d nails. 3) Maximum hole size = 2˝.
120
USPStock No.
SteelGauge
Fastener Schedule1,2CodeRef.
W
5˝
2 5/8˝
2 1/2˝
STS
Stud Shoes – STS series
SMP
28 1/16˝
5 5/8˝
4 ˝
SFP30
Ref. No.
SFP30 FPBS44 SMP FPBM44
USPStock No.
CodeRef.
120
Take the work out of fence post installation andrepair with the Speedpost, SFP30, andSpeedmender, SMP. The Speedpost is used toinstall 4 x 4 fence posts without digging postholes or pouring concrete. The Speedmenderplates act as reinforcement brackets for rotted ordamaged 4 x 4 fence posts.
SFP30 – For 6´ nominally-sized 4 x 4 fenceposts.
SMP – Available for nominally-sized 4 x 4posts.
Materials: 13 gaugeFinish: PaintPatent: #7,152,841
Installation:• Step-by-step installation instructions are labeledonto each product.
Mis
cella
neou
s
Fence Post Connectors – SFP & SMP series
Mis
cell
an
eou
s
1-800-328-5934 • www.USPconnectors.com186
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®Fence Brackets – ERB24, FB, FC & FRB series
W
H
FC24-TZ
Typical FC24-TZinstallation
HW
FRB24-TZ
Typical ERB24-TZinstallation
WH
Typical FRB24-TZinstallation
ERB24-TZ
1 1/2˝ 1 3/16˝
2 3/8˝
1 9/16˝
FB23-TZ FB14-TZ
Ref. No. Qty Type Qty Type
PRT2-TZ PGT2Z-R 16 1 1/4˝ HDG carriage bolt 4 1/4˝ lag bolt 120
1) WS15 wood screws can be substituted for specified lag bolts.
CodeRef.
USPStock No.
SteelGauge
Pipe Rail
Fastener Schedule1
ERB24 – Designed to mount prefabricated fencesections and works with 2x4 horizontal section rails.
FRB24 – Secures continuous 2x4 rails to woodposts. Prepunched holes allow installers to splice2x4 rail ends within the bracket.
Materials: See chartFinish: G-185 galvanizing
Installation:• Use all specified fasteners. See Product Notes,page 11.
Pipe Rail Tie – PRT2-TZ
Use the PRT2-TZ to quickly connect 2˝ (2 3 ⁄ 8˝ outside diameter) vertical pipe posts to wood fence rails.
Materials: 16 gaugeFinish: G-185 galvanizing
Installation:• Fasten with (1) 1⁄4˝ carriage bolt and nut (included) for tightening Pipe Rail Tie to pipe and (4) 1⁄4˝ lag bolts for attaching tie to rail.
2˝
PRT2-TZ
Typical PRT2-TZinstallation
Rail Size Ref. No W H Rail Post
1 x 4 FB14-TZ -- -- 20 3/4 3-1/2 (3) 8d x 3/4 (2) 8d x 1-1/2 2 x 3 FB23-TZ -- -- 20 1-9/16 2-3/8 (3) 8d x 1-1/2 (4) 8d x 1-1/2
ERB24-TZ -- -- 18 1-1/2 3-9/16 (4) 8d (3) 8d
FC24-TZ FB24, FB24Z, FBR24, FBR24Z
20 1-9/16 3-3/8 (5) 6d (3) 8d
FRB24-TZ -- -- 20 1-9/16 3-9/16 (2) 10d x 1-1/2 (4) 10d
1) Minimum nail penetration shall be 1-1/8˝ for 6d nails, 1-5/16˝ for 8d nails, and 1-1/2˝ for 10d nails. 2) 8d x 1-1/2 nails are 11 gauge (0.131˝ diameter) by 1-1/2˝ long. 3) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. New products or updated product information are designated in bold font.
USPStock No.
SteelGauge
Dimensions
CodeRef.
120
Fastener Schedule
2 x 4
USP2173-111
Deck Tie Bracket – DTB-TZ seriesM
iscella
neou
s
1-800-328-5934 • www.USPconnectors.com 187
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
Deck Post Ties – SDJT14 & SDPT series
Typical SDPT7-TZinstallation
Ref. No. Qty Type Qty Dia. 100% 115% 125% 100% 115% 125%
2 x 4 SDPT5-TZ DPT5Z 14 5 10d x 1-1/2 2 3/8 -- -- -- -- -- -- -- -- -- -- -- --
4 x 4 SDPT7-TZ DPT7Z 14 5 10d x 1-1/2 2 3/8 -- -- -- -- -- -- -- -- -- -- -- -- 4 x 4 SDJT14-TZ DJT14Z 14 8 16d 2 3/8 1120 1290 1400 1400 1400 1400 130
1) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long. 2) Nails require a minimum embedment length of 1-5/8˝ for 16d nails. 3) Bolts shall conform to ASTM A 307 or better.
Allowable Loads (Lbs.)
BoltsUSPStock No.
Fastener Schedule
SteelGauge
DF-L / SPNails1,2 Bolts3
CodeRef.
120
PostSize
Nails
SDPT – Connects 2 x 4 stair posts and 4 x 4 posts to deck rim joistor stair stringers.
SDJT14 – Secures 2x joists to posts.
Materials: 14 gaugeFinish: G-185 galvanizing
Installation:• Use all specified fasteners. See Product Notes, page 11.• SDPT5-TZ & SDPT7-TZ – Install units in pairs on 2x4 (SDPT5-TZ)or 4x4 (SDPT7-TZ) post. Space the connectors 5˝ apart from centerto center on the post. Use through bolts to fasten connectors to rimjoist or stringer. Do not use lag bolts. Fasten to post with specified nails(see chart).• SDJT14-TZ – Use with 2x lumber for joists (minimum height is 2x4).Install with either specified nails or through bolts. Do not use lag bolts.To ease installation, attach to 4x4 post first.
3 1/2˝
1 1/2˝
3 1/2˝
1 1/2˝
1 1/2˝
3 1/2˝
2 3/4˝
3 1/8˝
3 1/8˝
SDJT14-TZ
Typical SDJT14-TZinstallation
SDPT5-TZ
SDPT7-TZ
Deck Tie Brackets reinforce the connection of rail poststo a deck. Also provides lateral strength of deck-to-ledgerattachment by securing deck to house framing.
Materials: 14 gaugeFinish: G-185 galvanizingCodes: ER-0200
Installation:• Use all specified fasteners.• Position DTB-TZ on deck joist in a location where thethreaded rod or bolt may be threaded through the bolthole.• Drive WS15-GC wood screws into joist. • Re-install threaded rod or anchor bolt. Secure withwasher and nut. • Tighten anchor bolt nuts finger tight snug to base plus1⁄3 to 1⁄2 additional turns with wrench. To prevent loosening of the anchor nut during critical loading, use alocking nut or tighten a second nut over the first to locknuts in place.
Typical DTB-TZinstallation
Typical DTB-TZ Deck to ledger installation
DTB-TZ
Ref. No. CL Qty100% 160%
∆ (in)
at 160%2100% 160%
DTB-TZ DTT2Z, DTT2Z-SDS2.5, FSC
1/2 1-1/8 8 WS15-GC 1835 1835 0.119 1510 1510 20
1) WS15-GC Wood Screws are 1/4" dia. x 1-1/2" long and are included with DTB-TZ Deck Tie-Backs. 2) Deflections are derived from static, monotonic load tests of devices connected to DF-L wood members with specified fasteners.
CodeRef.
DF-L / SP
Fastener Schedule1
USPStock No.
WoodScrews
Rod / BoltAnchor
Dia.
Allowable Tension (Lbs)
S-P-F
The building codes specify that thedeck to the house attachment must bedesigned to resist lateral loads. The lateral load connection shall be per-mitted to be in accordance with FigureR502.2.2 of the InternationalResidential Building Code. Holdowntension devices shall be provided innot less than two locations per deck,and each device shall have an allowable stress design capacity ofnot less than 1500 lbs.
Mis
cell
an
eou
s
1-800-328-5934 • www.USPconnectors.com188
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
Connects deck boards to joists without face nails or screws.Eliminates rust stains on decks, as well as splintering or wood rotcaused by screw or nail “craters”. The DC50-TZ works like tongue-in-groove flooring and is easy to install. Raised dimples on the clip provide consistent spacing between deck boards.
Materials: 20 gaugeFinish: G-185 galvanizing
Installation:• Use all specified fasteners. See Product Notes, page 11.• Fits 11/8˝ or thicker decking. • Fasten the first deck board onto the joists by toenailing upthrough the joist below into the deck board. Be sure no sharppoints protrude above the deck surface. For subsequent deckboard rows, nail DC50-TZs onto the deck board edge, positioned2˝ from each joist. Slide the deck board along the joist until theDC50-TZ “lip” is under the previously laid deck board. Toenail thedeck board’s exposed edge to the joist. Repeat until decking iscompleted. The last deck board will require toenailing up frombelow to secure the outside edge.
Deck Clip – DC50
Typical DC50-TZ
installation
DC50-TZ
Ref. No. Qty Type
DC50-TZ DBT1Z 20 1 8d x 1-1/2 HDG 120
1) 8d x 1-1/2 nails are 11 gauge (0.131˝ diameter) by 1-1/2˝ long. 2) Use with 1-1/8˝ minimum thickness decking.
USPStock No.
SteelGauge
Fastener Schedule1,2CodeRef.
Anchors 4 x 4 post to wood or concrete surfaces.
Materials: 13 gaugeFinish: Paint
Patents: #7,152,841
Installation:• Use all specified fasteners. See Product Notes, page 11.
Post Size Ref. No. Qty Lag Bolts
4 x 4 BD FPBB44 13 4 1/4" x 1-1/2" HDG 120
USPStock No.
SteelGauge
Fastener Schedule CodeRef.
5 5/8˝
4 ˝
BD
Bolt Down – BD
Typical BDinstallation
USP2173-111
Concealed Stringer Hanger – CSH-TZM
iscella
neou
s
1-800-328-5934 • www.USPconnectors.com 189
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
Typical CSH -TZinstallation
The CSH-TZ concealed stringer hanger provides a method of connecting a stair stringer with ahidden hanger. The seat of the hanger is adjustable to match the slope of the stair stringer.The reversible design allows the connector to be used on the left, right, or interior stringers. TheCSH-TZ may be used with USP’s SCA Stair Angles for a complete, easy-to-use stair framingsolution.
Materials: 18 gaugeFinish: G-185 galvanizing
Patents: #7,631,463
Installation:• Use all specified fasteners. See product notes page 11.• Bend angle only once.
Steps:1. Attach CSH-TZ to header with tabs positioned towards the inside of the stringer member. 2. Adjust the seat of the CSH-TZ to match the slope of the stringer member. Diamond shapedholes in the connector allow temporary installation of woodscrews to aid in installation of theCSH-TZ.3. Install 10d x 1 1/2˝ nails into the stringer and header members
Uplift1 Uplift1
Ref. No. Qty Type Qty Type 100% 115% 125% 160% 100% 115% 125% 160%
CSH-TZ LSCZ 18 8 10d x 1-1/2 HDG 5 10d x 1-1/2 HDG 890 890 890 390 745 745 745 310 110
1) Uplift loads are increased 60% for wind or seismic loads; no further increase shall be permitted. 2) 10d x 1-1/2 nails are 9 gauge (0.148˝ diameter) by 1-1/2˝ long.
CodeRef.
Allowable Loads (Lbs.)Fastener Schedule2
USPStock No.
SteelGauge
DF-L / SP S-P-F / Hem FirHeader Joist CSH-TZ
Adjustable
5˝
5˝
1 1/2˝1 1/2˝
Stair Angles – SCA series
Stair angles simplify stair construction. There is no need to calculate and notch stair stringers.Stronger and safer than wood blocking, and the angle and fasteners are hidden from view.
Materials: 12 gaugeFinish: G-185 galvanizing; SCA9-GC & SCA10-GC – Gold CoatCodes: ESR-1280, L.A. City RR 25749, FL11664
Installation:• Use all specified fasteners. See Product Notes, page 11.• Use the SCA9-TZ for single 2x10 stair treads. Use the SCA10-TZ for double 2 x 6 stair treads.• To calculate stair construction do the following:
1. Find the number of steps needed by taking the vertical drop from the deck surface to grade. Divide by 7. Round off to the nearest whole number. (Ex: Vertical drop of 39˝ divided by 7 equals 5.57˝ rounded off is 6˝)
2. Find the step rise by dividing the vertical drop by the number of steps (39˝ divided by 6 = 6.5˝)
3. Find the step run by measuring the depth of your treadboard (Ex: (2) 2x6s have a run of 111⁄4˝)
4. Find the stairway span by multiplying the run by the number oftreads minus one (Ex: 111⁄4˝ x 5 = 561⁄4˝)
• Using the above calculations, mark stair angle locations on each stringer. Attach a stairangle to the inside of each stringer at the marked locations. Attach stringers to deck rim joistand railing posts. Position treadboards on angles and fasten from below.
L1 3/8˝
1 3/8˝
SCA9-TZ
Allowable Download (Lbs.)1
DF-L / SP
Ref. No. L Qty Type 100%
SCA9-TZ TA9Z 6 1/4˝ x 1-1/2" HDG Lag Screws SCA9-GC -- -- 6 WS15-GC
SCA10-TZ TA10Z 12 10 8 1/4˝ x 1-1/2" HDG Lag Screws 450
1) Loads assume rise over run of 7/11. 2) WS15-GC Wood Screws are 1/4˝ x 1-1/2˝ long.
Fastener Schedule2
2,F20,R12
CodeRef.
USPStock No.
SteelGauge
335912
Typical SCA9-TZinstallation
Typical SCA10-TZinstallation
Mis
cell
an
eou
s
1-800-328-5934 • www.USPconnectors.com190
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
Wall Ties – WT22
Hoist Plates – T10
Materials: 22 gaugeFinish: G90 galvanizing
Installation:• Use nails appropriate for intended use. See Product Notes,page 11.• The opposite end must be bonded in the mortar joint ofbrick facade.• Check local codes for spacing requirements.• Wall tie shall be bent at nail, bonding into mortar joint.
Ref. No. Description W L
WT22 BTB Straight Edge - Duplex 22 7/8 6-1/2 120.
CodeRef.
USPStock No.
SteelGauge
Dimensions
WT22
6 1/2˝
7/8˝
Typical T10installation
Ref. No. Qty Type
T10 -- -- 14 10 8d common 800 130
1) Minimum nail penetration shall be 1-5/16˝ for 8d nails.
CodeRef.
Max Load(Lbs.)
USPStock No.
SteelGauge
Minimum Fastener Schedule1
3˝
1 1/2˝
6 15/16˝
5 1/2˝
Engineered with a reinforced collar around thehoist hole for added strength.
Materials: 14 gauge
Installation:• Fill all nail holes that align with wood.
T10
Plastic Post Caps – PCP series
These seamless caps keep water off post tops, protecting wood from moisture damage. The PCP’splastic construction is corrosion-proof and paintable. Not available in rough or full lumber sizes.
Materials: Hi-impact plasticFinish: Gray
Installation:• Fasten cap to post top with (1) 8d HDG or 10d HDG nail.• See Product Notes, page 11.
Typical PCP44installation
Dimension
Ref. No. W Color
4 x 4 PCP44 DPPC4BK 3-5/8 Gray
6 x 6 PCP66 DPPC6BK 5-5/8 Gray
1) Not available in rough or full lumber sizes.
Post /Column Size1
USPStock No.
CodeRef.
120
PCP66
WW
1 ˝ spacebetweenbrick and sheathing
Typical WTinstallation
USP2173-111
Mis
cella
neou
s
1-800-328-5934 • www.USPconnectors.com 191
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
Drywall Clip – DC1
Plywood Clips – PC & RC series
Typical PCinstallation
Provides 1/8˝ gap
Ref. No. With PC Without PC
24 RC38-250 PSCL3/8 18 24 20 3/8 124 PC716 PSCL7/16 20 24 24 7/16 1
32 PC1532 PSCL15/32, PSCA15/32
20 32 28 15/32 1
32 PC12 PSCL1/2 20 32 28 1/2 140 PC1932 PSCL19/32 20 40 32 19/32 2
40 PC58 PSCL5/8 20 40 32 5/8 248 PC34 PSCL3/4 20 48 36 3/4 2
1) Based on code specified allowable spans for panel sheathing continuous over two or more spans with plywood strength axis perpendicular to supports. 2) Applicable to roof sheathing. 3) Applies to panels 24˝ or wider. 4) Uniform load deflection limitations 1/180 of span under live load plus dead load or 1/240 under live load only.
CodeRef.
120
PlywoodThickness (Inches)
PC'sPer Span
Maximum Span1Span
Rating1
USPStock No.
SteelGauge
PC
RC
Steel plywood clips. All models feature embossed dimples to provide 1/8˝ gap.
Materials: 20 gaugeFinish: G90 galvanizing
Typical DC1installation
1 1/2˝1 1/8˝
3/4˝
DC1
Drywall clips or “stops” help support drywall or wood panelingand reduce wood blocking on top plates, end walls, and corners.
Materials: 20 gaugeFinish: G90 galvanizing
Installation:• Use 8d nails to install DC1, 16˝ on-center or less.
Ref. No. Qty Type
DC1 DS 20 1 8d 120
1) Minimum nail penetration shall be 1-5/16˝ for 8d nails.
USPStock No.
SteelGauge
Fastener Schedule1CodeRef.
Insulation Supports – IS series
Simply pushinto place
Typical ISinstallation
Dimensions
Ref. No. Overall Length
IS16 IS16 13 16˝ O. C. 15-1/2˝
IS24 IS24 13 24˝ O. C. 23-1/2˝
USPStock No.
SteelGauge
120
CodeRef.
JoistSpacing
Insulation supports secure batt-type insulation in place betweenjoists. Chisel-cut ends dig into joists for permanent holding. Easy toinstall in hard-to-reach crawl spaces.
Materials: 13 gauge carbon steel wireFinish: None
Installation:• Use IS16 for joist spaced 16˝ O.C. and IS24 for 24˝ O.C. spacing.• Position insulation batt in place between joists. Hold IS unit at the center and push into place.• Wear gloves and safety glasses during installation.
Mis
cell
an
eou
s
1-800-328-5934 • www.USPconnectors.com192
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
Ref. No. W L
JNP24 -- -- 18 1-1/2 4
JNP26 -- -- 18 1-1/2 6 JNP46 -- -- 18 3-3/16 6
JNP48 -- -- 18 3-3/16 8 TPP14 MP14 22 13/16 3-1/2
TPP24 MP24 22 1-11/16 3-1/2
TPP36 MP36 22 2-3/4 5-1/4 TPP58 -- -- 22 4-3/16 7-13/16
120
DimensionsUSPStock No.
SteelGauge
CodeRef.
Mending Plates – JNP & TPP series
Typical Nail Plate installation
Typical KSCT68installation
The Corner Tie secures three-way wood-to-woodconnections. Handy for building workbenches, utilitytables, or shelving using 2x4 lumber.
Materials: 14 gaugeFinish: G90 galvanizing
Installation:• Use (12) #10 panhead screws to fasten the KSCT68to wood framing.
6˝
2˝
8˝
KSCT68
Materials: 20 gaugeFinish: G90 galvanizing
Installation:• Use nails appropriate for intended use. Holes are sizedfor 8d common or 8d x 11⁄2˝ nails.• The designer shall determine appropriate load values.
NPDimensions
Ref. No. W L
NP15 TP15 20 1-13/16 5 12
NP35 TP35 20 3-1/8 5 22 NP37 TP37 20 3-1/8 7 31
NP39 TP39 20 3-1/8 9 40 NP311 TP311 20 3-1/8 11 49
NP45 TP45 20 4-1/8 5 30
NP47 TP47 20 4-1/8 7 42 NP49 TP49 20 4-1/8 9 54
NP411 TP411 20 4-1/8 11 66 NP57 TP57 20 5-3/4 7 59
USPStock No.
SteelGauge
Number ofNail Holes
120
CodeRef.
Typical Mending PlateinstallationTPP
JNP
TPP – Prong plates with straight prongs.
JNP – Prong plates with angled, hammer-in prongs.
Materials: See chartFinish: G90 galvanizing
Installation:• These products are not intended for structural use. No load ratingsare assigned. These plates are not intended for use in truss assembly.
Nail Plates – NP series
Corner Tie – KSCT68
Typical JNinstallation
Typical MTHFinstallation
Power Nail Hangers – JN, JN(E), MRT7, & MTHF series
Designed for assembly line installation, these hangers feature a generous flange area to accommodate power nailer maneuvering. Engineered for economical installationand maximum load values.
Materials: 18 or 20 gaugeFinish: G90 galvanizingCodes: ESR-1465, FL817
Installation:• Use all specified fasteners. See Product Notes, page 11.
MTHF25925
2 1/2˝211/16˝
1 1/8˝
9 1/8˝ H
WD
A
JN26EMRT7
1 9/16˝
5 1/4˝
Floor Uplift4
Ref. No. W H D A Qty Type Qty Type 100% 115% 125% 160%
3 "P" nails 3 "P" nails 175 205 220 285
4 "P" nails 4 "P" nails 235 270 295 380
5 "P" nails 5 "P" nails 295 340 370 4706 "P" nails 6 "P" nails 355 405 445 565
10 "P" nails 4 "P" nails 590 680 740 38016 "P" nails 4 "P" nails 945 1085 1180 380
10 "P" nails 4 "P" nails 590 680 740 380
16 "P" nails 4 "P" nails 945 1085 1180 38010 "P" nails 4 "P" nails 590 680 740 340
16 "P" nails 4 "P" nails 945 1085 1180 34020 "P" nails 4 "P" nails 1415 1430 1430 340
10 "P" nails 4 "P" nails 590 680 740 340
16 "P" nails 4 "P" nails 945 1085 1180 34020 "P" nails 4 "P" nails 1415 1430 1430 340
10 "P" nails 4 "P" nails 590 680 740 34016 "P" nails 4 "P" nails 945 1085 1180 340
20 "P" nails 4 "P" nails 1415 1430 1430 340
10 "P" nails 6 "P" nails 600 690 750 57516 "P" nails 6 "P" nails 960 1105 1200 575
24 "P" nails 6 "P" nails 1440 1655 1800 57510 "P" nails 6 "P" nails 600 690 750 575
16 "P" nails 6 "P" nails 960 1105 1200 575
24 "P" nails 6 "P" nails 1440 1655 1800 575
1) "P" nails denotes fasteners designed specifically to be installed with a pneumatic-powered nailer. The fasteners shall be either of a type with round heads, 0.105˝ diameter and 1-3/8˝ long; or a "T" shaped head, 0.097˝ diameter, 1-1/4˝ long and hardened; or a similar but larger fastener. 2) Fasteners shall be pneumatically driven in such a way as firmly seats the nail head against the hanger steel, without embedding the nail head completely through the plane of the metal surface, or otherwise punching through. 3) The quantity of nails installed shall be equally distributed to both sides of the hanger. The nails shall be located at 1˝ spacing in a row, with the vertical rows spaced at 3/8˝; also no less than 5/16˝ from a sheared edge and no less than 5/16˝ from a formed edge. 4) Uplift loads have been increased 60% for wind or seismic load conditions; no further increase shall be permitted.
Header Joist
Fastener Schedule1,2,3
USPStock No.
SteelGauge
Dimensions Allowable Loads (Lbs.)
Roof
JN26E
JN28E
20
20
2
2
MRT7 -- --
JN210E
JN26-2
JN28-2
MMLU26
MMLU28
MMLU210
MMLU28-2
20
MMLU26-2 18
18
1-1/4
1-1/4
1-9/16
1-9/16
1-9/16
1-1/4
3-1/16
3-1/16
6-3/4
5-1/4
1-5/8
1-5/8
8-1/4
5-3/8
7-1/8
1-5/8
1-5/8
2
18 -- -- -- --1-9/16 5-1/4
MTHF25925 MMLUI39 20
MMLUI311 20 MTHF25112
2-1/2 1-1/8
2-1/2 1-1/8
2-1/2
2-1/2 11-1/8
9-1/8
CodeRef.
130
11,F12
DF-L / SP
USP2173-111
Man
uf. H
ou
sin
g
1-800-328-5934 • www.USPconnectors.com 193
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
Specia
lty
Op
tion
s
1-800-328-5934 • www.USPconnectors.com194
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®Specialty Options & General Notes
USPSeries Width S
kew
ed (M
axim
um)
Slo
ped
Seat
(Max
imum
)
Slo
ped
/ Ske
wed
Slo
ped
Top
Flan
ge (M
axim
um)
Top
Fla
nge
Offs
et
Sad
dle
Han
ger
Rid
ge H
ange
r (M
axim
um)
Inv
erte
d Fl
ange
Upl
ift
Wel
dabi
lity
USP
Ser
ies
Cat
alog
Pag
e R
efer
ence
BPH all 50º 45º • 45º • •123, 127, 129,131, 133-134
GHF all 50º 45º ••
width > 4-1/2˝• 137
1-3/4˝ or less 67-1/2º
> 1-3/4˝ 50º
1-3/4˝ or less 67-1/2º
> 1-3/4˝ 50º
HJC all 60º 169-170
HLBH all 50º 45º • 45º • • 45º • •124, 129-131, 133-
134
HUS all•
width > 2-1/4˝•
88, 90-94, 117,121, 162
HWUH all 45º 45º • • • • 106-107
KEG all 45º 45º • 138 KGB all • • 139
KGH all 45º • 34
KGLS all 50º 45º • 30º • • • • 143 KGLST all • • • 143
KGLT all 50º 45º • 45º • • • • 140
KHGB all • • 139 KHGLS all 50º 45º 30º • • • • 143
KHGLST all • • • 143 KHGLT all 50º 45º • 45º • • • • 140
KHHB all • • 139
KHW all 84º 45º • 35º • • 45º • 97, 100
KLEG all 45º 45º • • 138 KMEG all 45º 45º • • 138
LSSH all 45º 45º • • 136
MPH1 all 60º 45º • •108-109,125-134
NFM all 45º • 110
PHM all 84º 45º • 35º • • 45º • 125-134
PHXU1 all 60º 45º • 35º • • • •125-127, 129-131,
133-134
SKH all 45º • 102-103 SKHH all 45º • 102-103
1-3/4˝ or less 67-1/2º> 1-3/4˝ 50º
SW1 all 84º 45º • 35º • • 45º • 97-99
SWH1 all 84º 45º • 35º • • 45º • 97-100
THDH all 45º 45º • • 118, 121-122, 161
1-3/4˝ or less 67-1/2º
> 1-3/4˝ 50º
1) Skews greater than 45° will have square (butt) cut joist with back plate. Refer to Typical PHXU hanger skewed, left shown, Type B illustration on page 196.
116,119-120
89-95, 116, 120-122
96, 98-100
87, 90-95
118,121-122,
160 THD all
THF
45º 45º •
45º •
•
•width > 2-1/4˝
•one flangewidth > 3˝
•
•
•
45º
45º
SUH 45º
HD1
HDO
••
width > 2-1/4˝•
••
width > 3-1/8˝•
The information listed only applies tohangers manufactured by USPStructural Connectors® and installedaccording to the instructions listed inthis catalog. Some of the options listed may not have been evaluatedon a single hanger. The designermust always evaluate each connection, including the joist andheader capacities, before specifyinga specialty connector. USP slopedhangers are manufactured with theplumb cut of the joist already calculated. If a hanger with a different height is needed, it must bespecified at the time of ordering.
Materials: Steel gauge may varyfrom that specified depending on thespecialty option and manufacturingprocess used. Some formed hangersmay be welded when modifying thehanger. Hanger configurations, fastener schedules, and height mayvary from the tables depending onthe joist size, skew, and slope.
Finish: See specific hanger optiontables. Welded hangers are paintedwith USP gray primer. Non-cataloghangers available in Hot-dip galvanized, use HDG after productnumber.
Allowable Loads: For multipleoptions for the same connector, usethe most conservative reduction togive the lowest design load.
Installation:• Fill all nail holes with fastenersspecified in the tables.• Fastener quantities may increasefrom the amount listed in the tablesdepending on hanger option.• NA16D-RS and NA20D nails aresupplied with hangers.• For type A skewed hangers, the endof joist must be bevel cut; for type Bskewed hangers, the end of joistmust be butt-cut.
Codes: Modified hangers are notcode evaluated due to their numerous variations.
USP2173-111
Sp
ecia
lty O
ptio
ns
1-800-328-5934 • www.USPconnectors.com 195
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
Slope angle
Skew angle
Typical HD hangersloped seat,down shown
Typical HD hangersloped down,
skewed left shown
Plumbheight
Specifyangle
Joistheight
Specify angle
Typical SUH formedhanger skewed,
right shownType B
Typical HD hangerinverted flange
Typical GHF hangerone flange inverted,
left shown
H
2 1/8˝
Specify angle
Typical SUH hangerskewed, right shown
Type A(bevel cut required)
Face Mount Hanger Specialty Details
See the Specialty Options Chart for each hanger series for load reductions and hanger maximum range of skew, slope, etc.
Skewed Hanger:• Consider SKH or SKHH hangers for 45° skews.• Joist nails may be located on obtuse side to ensure proper
nailing.• Specify skew angle, type (A or B), and direction when
ordering.
Sloped Seat Hanger:• Consider LSSH series for sloped applications.• Additional nail holes may be added to joist flanges.• Specify slope angle and direction when ordering.
Sloped/Skewed Hanger:• See nailing notes for both skewed and sloped hangers.• Specify skew and slope angles as well as skew/slope
directions and skew type (A or B) when ordering.
Inverted Flange Hanger:• For skewed-only hangers, the flange on the cut side can be
inverted at 100% of the table load. Consult USP for skew limitations.
• When nailing into the carrying member’s end grain, the allowable load is 0.65 of the table load.
• Hangers with one flange inverted achieve 100% of listed table load.
• Specify right or left flange when inverting only one flange.
Specia
lty
Op
tion
s
1-800-328-5934 • www.USPconnectors.com196
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
Slopeangle
Specifyangle
Joist skewright shown
Specify angle
Specify angle
Open Top Flange Hanger Specialty Details
Skew angle
Slope angle
Specify angle
high side flush
low side flushcenter flush
Typical BPH hangerskewed right,
sloped down, topflange sloped
Specify angle
Typical BPH hangerskewed, left shown
Type A(bevel cut required)
Specify angle
Typical PHXU hangerskewed, left shown
Type B
Typical PHXU hangerskewed, left shown
Type A(bevel cut required)
Plumbheight
Specifyangle
Joistheight
Typical BPH hangersloped seat,down shown
Typical BPH hangersloped down,
skewed right, lowside flush shown
Typical HLBH hangersloped top flange
right shown
Typical BPH hangerskewed, right shown
Type B
See Specialty Options Chart for each hanger series for load reductions and hanger maximum range of skew, slope, etc.
Skewed Hanger:• Joist nails may be located on obtuse side to ensure proper
nailing.• Specify skew angle, type (A or B), and direction when ordering.
Sloped Seat Hanger:• Additional nail holes may be added to joist flanges.• Specify slope angle, direction, and joist height when ordering.
Sloped/Skewed Hanger:• See nailing notes for both skewed and sloped hangers.• Specify skew and slope angles as well as skew/slope
directions, and skew type (A or B) when ordering.• Specify if hanger is to be high side flush, low side flush, or
center flush.
See Specialty Options Chart for each hanger series for loadreductions and hanger maximum range of skew, slope, etc.
Skewed Hanger:• Joist nails may be located on obtuse side to ensure
proper nailing.• Specify skew angle, type (A or B), and direction
when ordering.
Sloped Seat Hanger:• Additional nail holes may be added to joist flanges.• Specify slope angle, direction, and joist height when
ordering.
Sloped/Skewed Hanger:• See nailing notes for both skewed and sloped hangers.• Specify skew and slope angles as well as skew/slope
directions, and skew type (A or B) when ordering.• Similar to face mount skewed/sloped hanger, refer to
illustration on page 195: Typical HD hanger sloped down, skewed left shown.
• Specify if hanger is to be high side flush, low side flush, or center flush.
Sloped/Skewed/Sloped Top Flange Hanger:• See nailing notes for both skewed and sloped hangers.• Specify skew, slope, and top flange slope angles as
well as skew/slope and top flange slope directions when ordering.
• Skewed/sloped/top flange sloped hangers can be made galvanized or painted.
continued on next page
Solid Top Flange Hanger Specialty Details
USP2173-111
Sp
ecia
lty O
ptio
ns
1-800-328-5934 • www.USPconnectors.com 197
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®Solid Top Flange Hanger Specialty Details continued
Skew angle
Slope angle
Plumbheight
Specifyangle
Joist Height
Specifyangle
W2SA
H2
W1
H1
Specify angle
Slope angle
Joist skewright shown
Typical HLBH hangersloped seat, down
shown
Typical HLBH hangersloped down, skewed
right, low sideflush shown
Typical HLBH hangerridge, top
flange slope
Typical PHXU hangersaddle option
Typical HLBH hangerskewed right, sloped
down, top flange sloped
Typical HLBH hangertop flange offset,
right shown
Specify angle
high side flush
low side flushcenter flush
Typical HLBH hangersloped top flange,
right shown
Sloped Top Flange Hanger:• Additional nail holes may be added to top angle.• Specify top flange slope and direction when ordering.• Specify if hanger is to be high side flush, low side
flush, or center flush.
Ridge Hanger:• Specify flush top of beam at center, right side, or
left side.• Specify angle of slope when ordering.
Top Flange Offset Hanger:• Specify offset, left (L) or right (R), when ordering.
Saddle Hanger:• Specify saddle width, “SA” when ordering. Allow
clearance for saddled member.
Specia
lty
Op
tion
sWelded Top Flange
1-800-328-5934 • www.USPconnectors.com198
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
Typical Top Flangewelded installation
Continuous weld alongback of top flange
Typical Top Anglewelded installation
Typicalsee chart
SW 3˝
BPH, PHM, SWH 4˝
KHW, PHXU 6˝
HLBH, KHGLT 10˝
Weld shall be distributed evenly.
KGB, KHGB, KHHB, KGLS, KGLST, KGLT, KHGLS, KHGLST
8˝
USPWelded Hanger Series
WeldLength
10 gauge or lighter 1/8˝
7 gauge 3/16˝
3 gauge 1/4˝
Top AngleSteel Gauge
WeldSize
• Weld sizes and lengths shown on chart.• Weld-on applications produce maximum allowableload listed. Uplift loads do not apply to this application.
Top Angle Weld Length chart
Part Number System
THO35925-2THO 35 925
Lettersrefer toHangerSeries
ex.: THO
First (2) Digitsrefer to
Member Widthex.: 3.5 inches
Last (2) or (3) Digitsrefer to
Member Heightex.: 9.25 inches
Part Number Guide for Decimals
1 = .125 or 1/8 inch2 or 25 = .25 or 1/4 inch
3 = .3125 or 5/16 inch5 = .5 or 1/2 inch6 = .625 or 5/8 inch7 = .75 or 3/4 inch8 = .875 or 7/8 inch
Some Examples:THO15950 ................................1-1/2˝ x 9-1/2˝THF17925 ................................1-3/4˝ x 9-1/4˝THO16925-2..................double 1-5/8˝ x 9-1/4˝THF23140-2 ..................double 2-5/16˝ x 14˝
Note: USP’s Full Line Catalog lists a range ofheights for THF hangers. Face mount hangerscan usually accommodate more than one I-Joist height. The hanger height must be tallenough to support the top chord of the I-Joistto eliminate web stiffener requirements onsolid sawn or joists with web stiffeners. TheTHF hanger must be a minimum of 60% of thejoist height.
Part Numbers assigned to TFL, THO, and THFI-Joist hangers reveal the I-Joist sizes to beused with the specific hanger. This guide willteach you how to recognize I-Joist dimensionsin the part numbers.
-2Digits after
Dashrefer to
Number of Plysex.: 2 ply
TFL 23118
1st, 3rd, and sometimes 4th digits are
whole numbers
(This example denotes 2 and 11)4th digit may be part of a decimal –
ex.: THO16925
2nd and 5th digits are decimals
(see guide below)
(This example denotes .3125[5/16] and .875 [7/8])5th digit may be (0) or dropped if
height is even
USP2173-111
Corro
sio
n P
rote
ctio
n
1-800-328-5934 • www.USPconnectors.com 199
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
USPStock No.
TripleZinc(TZ)
Hot-DipGalvanized
(HDG)
StainlessSteel(SS)
GoldCoat(GC)
USPStock No.
TripleZinc(TZ)
Hot-DipGalvanized
(HDG)
StainlessSteel(SS)
GoldCoat(GC)
USPStock No.
TripleZinc(TZ)
Hot-DipGalvanized
(HDG)
StainlessSteel(SS)
GoldCoat(GC)
AB1212-HDG X WAS46 X RT7 X X AB126-HDG X WAS66 X RT7A X X
AB128-HDG X WE44 X RT8A X X AB5812-HDG X WE46 X
BP12 X WE66 X A3 X
BP583 X AC5 X HBPS12 X C44 X X AC7 X X
LBP12-TZ X C46 X AC9 X LBP58-TZ X C66 X ANJ44S-HDG X
LBPS12-TZ X KCCQ325-4 X JA1 X
LBPS58-TZ X KCCQ325-6 X KHL35 X N8-GC X KCCQ44 X KHL43 X
N10-GC X KCCQ46 X MP34 X X N10C-GC X KCCQ525-4 X MP4F X
N16C-GC X KCCQ525-6 X MP5 X
NA11 X KCCQ64 X MP7 X X X NA9D X KCCQ66 X MP9 X X
NA16D X KECCQ325-4 X MPA1 X X X
THR125-HDG X KECCQ325-6 X THR126-HDG X KECCQ44 X RSPT6 X
THR128-HDG X KECCQ46 X RSPT6-2 X THR5816-HDG X KECCQ525-6 X SPT4 X
WS15-GC X KECCQ64 X SPT6 X
KECCQ66 X SPT22 X FA3 X PB44-6TZ X X SPT24 X
PA18 X PB66-6TZ X X SPTH4 X PA28 X PBC44-TZ X SPTH6 X
ST1-TZ X PBC66-TZ X
ST2-TZ X PBES44 X X KHST2 X STB34 X PBES66 X X KHST3 X
STBL24 X PBS44 X X KRPS22 X TA51 X PBS66 X X L6 X
TA71 X PCM4416 X MSTA9 X
TDL5 X PCM4616 X MSTA12 X X TDX2-TZ X PCM6616 X MSTA15 X
MSTA18 X X HTA20 X HUS28-2IF X MSTA21 X
HUS210-2IF X MSTA24 X X
LJC-TZ X JL24IF-TZ X MSTA30 X LJQ15-TZ X JL26IF-TZ X MSTA36 X X
LJQ17-TZ X JL28IF-TZ X PS218-HDG X LJQ20-TZ X JL210IF-TZ X PS418-HDG X
LJQ23-TZ X JUS24 X X X PS720-HDG X
LJQ25-TZ X JUS26 X X X RS150 X LJQ35-TZ X JUS28 X X X T6 X
JUS210 X X X CBSQ44-TZ X JUS26-2 X X X LTW12 X
CBSQ46-TZ X JUS28-2 X LTW18 X
CBSQ66-TZ X JUS210-2 X X X MTW12 X D44-TZ X JUS28-3 X MTW16 X
D46 X JUS210-3 X MTW20 X X D66 X JUS44 X
EBG44-TZ X JUS46 X CSH-TZ X
EPB4408 X LSSH15-TZ X X DC50-TZ X EPB4608 X LSSH210 X DTB-TZ X
EPB6608 X SKH26L X X X ERB24-TZ X KCBQ44 X SKH26R X X X FB14-TZ X
KCBQ46 X SKH28L X FB23-TZ X
KCBQ66 X SKH28R X FC24-TZ X KCBQ88 X SKH210L X X X FRB24-TZ X
PA44E X X SKH210R X X X ICPL58 X PA44-TZ X ICPL516-TZ X
PA46E X X HHCP2 X PRT2-TZ X
PA46-TZ X LFTA6 X SCA10-TZ X PA66E X X RT10 X X SCA9-GC X PA66-TZ X RT15 X X SCA9-TZ X PAU44 X X RT16-2 X X SDJT14-TZ X PAU46 X X RT16A X X SDPT5-TZ X
PAU66 X X RT3A X X SDPT7-TZ X PAU88 X X RT4 X X
WAS44 X RT5 X X
Fasteners / Anchors
Twist Straps
Miscellaneous
Hurricane / Seismic Anchors
Framing Plates & Angles
Stud Plate Ties
Straps
Column / Post Bases Hurricane / Seismic Anchors
Column / Post Caps
Joist Hangers
Holdowns / Foundation Anchors
Embedded Truss Anchors
Lateral Joist Connectors
Column / Post Bases
Corrosion Resistant Products
Notes
1-800-328-5934 • www.USPconnectors.com200
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®
USP2173-111
Notes
1-800-328-5934 • www.USPconnectors.com 201
©C
op
yrig
ht
2011
US
PS
tru
ctu
ral C
on
nec
tors
®
1-800-328-5934 • www.USPconnectors.com202
©C
op
yrigh
t 2011 US
PS
tructu
ral Co
nn
ectors
®Notes
USP HAS PARTNERED WITH STRUCTURAL SOFT TO PROVIDE THEINDUSTRY WITH THE BEST DESIGN SOFTWARE POSSIBLE!
USPPROFESSIONALDESIGNMANUALandPRODUCTCATALOG
56
thEditio
n
©2011 United Steel Products Company
USP 2173-111
USP MANUFACTURING& WAREHOUSE FACILITIES
Follow us on:
http://www.facebook.com/uspconnectors
http://www.twitter.com/uspconnectors
USP PROFESSIONAL DESIGN MANUALand PRODUCT CATALOG
56th Edition
concrete& masonry
connectors
rollstrapping
rafter tiedowns& plated truss
connectors
epoxies &mechanical
anchors
goldcoatconnector
series
hangers,angles
& straps
connect withconfidence
new PHDAholdown
series
A SUBSIDIARY OF MITEK INDUSTRIES, A BERKSHIRE HATHAWAY COMPANYA SUBSIDIARY OF MITEK INDUSTRIES, A BERKSHIRE HATHAWAY COMPANY
CCUUSSTTOOMMEERR SSEERRVVIICCEE//TTEECCHHNNIICCAALL AASSSSIISSTTAANNCCEE:: Phone: 1-800-328-5934
Fax: 1-952-898-8605
CORPORATE OFFICE14305 Southcross Drive - Suite 200
Burnsville, Minnesota 55306
Phone: 1-800-328-5934/1-952-898-8772
MANUFACTURING/WAREHOUSESMontgomery, Minnesota
Livermore, California
Largo, Florida
Thornhill, Ontario
Houston, Texas
Lumberton, New Jersey
2010 Catalog Cover:Layout 1 5/5/11 9:58 AM Page 1