UTP (Unshielded twisted Pair) 25 pair cable colorcoding as is often used in telephony systems. 1 WHITE-BLUE BLUE-WHITE 2 WHITE-ORANGE ORANGE-WHITE 3 WHITE-GREEN GREEN-WHITE 4 WHITE-BROWN BROWN-WHITE 5 WHITE-GREY GREY-WHITE 6 RED-BLUE BLUE-RED 7 RED-ORANGE ORANGE-RED 8 RED-GREEN GREEN-RED 9 RED-BROWN BROWN-RED 10 RED-GREY GREY-RED 11 BLACK-BLUE BLUE-BLACK 12 BLACK-ORANGE ORANGE-BLACK 13 BLACK-GREEN GREEN-BLACK 14 BLACK-BROWN BROWN-BLACK 15 BLACK-GREY GREY-BLACK 16 YELLOW-BLUE BLUE-YELLOW 17 YELLOW-ORANGE ORANGE-YELLOW 18 YELLOW-GREEN GREEN-YELLOW 19 YELLOW-BROWN BROWN-YELLOW 20 YELLOW-GREY GREY-YELLOW 21 PURPLE-BLUE BLUE-PURPLE 22 PURPLE-ORANGE ORANGE-PURPLE 23 PURPLE-GREEN GREEN-PURPLE 24 PURPLE-BROWN BROWN-PURPLE 25 PURPLE-GREY GREY-PURPLE RJ-45 CABLE (STRAIGHT) RJ-45 CABLE (CROSSED) 10/21/2010 UTP 25 pair Cable Colorcoding www.2ics.be/technical/technicalutp.htm 1/8

Upload: joel-dilan

Post on 08-Apr-2015

233 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: UTP 25 Pair Cable Color Coding

UTP (Unshielded twisted Pair) 25 pair cable colorcoding as is often used in telephony systems.

1 WHITE-BLUE BLUE-WHITE

2 WHITE-ORANGE ORANGE-WHITE

3 WHITE-GREEN GREEN-WHITE

4 WHITE-BROWN BROWN-WHITE

5 WHITE-GREY GREY-WHITE

6 RED-BLUE BLUE-RED

7 RED-ORANGE ORANGE-RED

8 RED-GREEN GREEN-RED

9 RED-BROWN BROWN-RED

10 RED-GREY GREY-RED

11 BLACK-BLUE BLUE-BLACK

12 BLACK-ORANGE ORANGE-BLACK

13 BLACK-GREEN GREEN-BLACK

14 BLACK-BROWN BROWN-BLACK

15 BLACK-GREY GREY-BLACK

16 YELLOW-BLUE BLUE-YELLOW

17 YELLOW-ORANGE ORANGE-YELLOW

18 YELLOW-GREEN GREEN-YELLOW

19 YELLOW-BROWN BROWN-YELLOW

20 YELLOW-GREY GREY-YELLOW

21 PURPLE-BLUE BLUE-PURPLE

22 PURPLE-ORANGE ORANGE-PURPLE

23 PURPLE-GREEN GREEN-PURPLE

24 PURPLE-BROWN BROWN-PURPLE

25 PURPLE-GREY GREY-PURPLE

RJ-45 CABLE (STRAIGHT) RJ-45 CABLE (CROSSED)

10/21/2010 UTP 25 pair Cable Colorcoding

www.2ics.be/technical/technicalutp.htm 1/8

Page 2: UTP 25 Pair Cable Color Coding

TIA-568-A is a document; T568A is a jack wiring pattern.

What a difference two letters and hyphens can make-at a glance these terms look so much alike it's easy to see how people can

confuse them. But it's an important distinction. TIA-568-A is the Commercial Building Wiring Standard; T568A is one of two jack

wiring patterns which comply with that standard (the other pattern is called T568B). For more information on wiring patterns, see page

2-9, Figure 2-9. The U.S. Government requires the use of the preferred T568A standard for wiring done under federal contracts.

T568A and T568B are the two wiring standards for an 8-position modular connector, permitted under the TIA/EIA-568-A wiring

standards document. The only difference between T568A and T568B is that the orange and green wire pairs (pairs two and three) are

interchanged.

Here's the cabling for telephone, or LocalTalk over PhoneNet, on a two-pair RJ-11. Telephone uses the innermost two wires for line 1.

The outermost two wires are line 2, or used for PhoneNet.

10/21/2010 UTP 25 pair Cable Colorcoding

www.2ics.be/technical/technicalutp.htm 2/8

Page 3: UTP 25 Pair Cable Color Coding

T568-A T568-B

ISDN equipment : wires 3 & 6 and 4 & 5

CROSS Cable wiring diagram:

STRAIGHT Cable wiring diagram :

10/21/2010 UTP 25 pair Cable Colorcoding

www.2ics.be/technical/technicalutp.htm 3/8

Page 4: UTP 25 Pair Cable Color Coding

Network Cables

How do i make a networkcable for an ethernet network ?

Wat er dan meestal bedoeld wordt is in welke volgorde moet je nu die 8 draadjes van die kabel in de stekkertjes doen?

Daar is niet zomaar een antwoord op te geven, rond die simpele kabeltjes valt namelijk nog veel meer te vertellen.

The Network Cable

First the cable itself. It is not enough just to twist 8 wires, wrapping an extra isolation around and you are ready. Forget it !!

Here we are talking about UTP-cable (Unshielded Twisted Pair).

Unshielded, because this cable is not, like the COAX cables that where used for networks in the past and still is used as antenna cable,

shielded.

That "shield" in these cables is a metal protection, that shields the wires inside for the radiation (so called "Faraday cage").

Twisted Pair because the 8 wires that are twisted around in pairs of two.

The 4 "pairs" are twisted again on their turn.

The following colors are used in pairs: ORANGE/ORANGE-WHITE, GREEN/GREEN-WHITE, BLUE/BLUE-WHITE en

BROWN/BROWN-WHITE.

There are different categories of UTP cables. We d'ont gonna talk about the older types, they are nearly not more available on the

market.

We start therefore by CAT 5. In most cases CAT 5 UTP cable is more than sufficient, only if you need extreme long cables.

An overview:

10/21/2010 UTP 25 pair Cable Colorcoding

www.2ics.be/technical/technicalutp.htm 4/8

Page 5: UTP 25 Pair Cable Color Coding

CATEGORY maximum length

CAT 5 100 meter

CAT 5e 350 meter

CAT 6 550 meter

CAT 7 700 meter

The RJ-plug The crimp tool

Push the 8 wires from the UTP-Cable in the RJ-plug.

With a special crimp tool, crimp the wires in the RJ-plug, and the cable and plug are secure. The crimp tool pushes the contacts in the

wires and crimps the end notch in the cable to secure them. Such a crimp tool is available for about 30 €.

The RJ-plug and the cable

We know what we need. Now we can put the plugs on the cable. But in what order we have to put them in the plug ?

This depends on the kind of cable you want to make:

Straight thru, you want to connect a few pc's with each other by means of a cable on an

HUB (or SWITCH or a ROUTER).

Crossover, you want to connect 2 pc's straight with each other, without a HUB (SWITCH or

ROUTER).

You also need a "crossover"-cable for a straight connection between a ROUTER and a pc.

Voor deze twee soorten kabels moeten de 8 draadjes in verschillend volgorde in de RJ45

stekkers gestopt worden.

Uiteraard is daar weer een standaard voor, er zijn er zelfs twee:

10/21/2010 UTP 25 pair Cable Colorcoding

www.2ics.be/technical/technicalutp.htm 5/8

Page 6: UTP 25 Pair Cable Color Coding

Je kunt aan de volgorde van de draadjes in het stekkertje dus zien wat voor standaard of

gebruikt is. Zelf gebruik ik altijd de 568B standaard voor normale (straight thru) netwerk

kabels. In Nederland is dat ook min of meer de standaard.

A networkcable in fact only uses 4 wires: these on the pins: 1, 2, 3 and 6. The other wires

d'ont do anything !!

That's not completely true, surely by longer cables, the other wires want zeker bij de langere

kabels zorgen de overige draden doordat alle draden in elkaar gedraaid zijn voor een goede

ontstoring. Daarom is het ook belangrijk de draden volgens één van de standaarden in de

stekkers te doen.

Nu kunnen we een kabel maken. Eerst de eerste stekker, de draadjes moeten in de volgende

volgorde geplaatst worden (568B standaard):

Hier zie je nog eens 4 afbeeldingen van een "Normale" UTP stekker !!!

Vervolgens schuif je de acht draden in de RJ45 stekker en met behulp van de krimptang zet

je de RJ45 stekker vast aan de UTP kabel.

10/21/2010 UTP 25 pair Cable Colorcoding

www.2ics.be/technical/technicalutp.htm 6/8

Page 7: UTP 25 Pair Cable Color Coding

UTP patch-kabel

Naming: UTP Straight Thru Patch cord

Standard: Standard EIA/TIA T568B

Alternatif names:AT&T specification. (Used to be named

258A.)

Layout (clip is on the underside)

pin 1: WHITE-ORANGE (TxData +)

pin 2: ORANGE (TxData -)

pin 3: WHITE-GREEN (RecvData +)

pin 4: BLUE

pin 5: WHITE-BLUE

pin 6: GREEN (RecvData -)

pin 7: WHITE-BROWN

pin 8: BROWN

Pin 1 en 2 vormen een paar (Transmit data) en pin

3 en 6 vormen een paar (Receive data).

UTP cross-cable

Naming: UTP Cross-cable cord

Layout (clip is on the underside)

Side 1

pin 1: WHITE-ORANGE (TxData +)

pin 2: ORANGE (TxData -)

pin 3: WHITE-GREEN (RecvData +)

pin 4: BLUE

pin 5: WHITE-BLUE

pin 6: GREEN (RecvData -)

pin 7: WHITE-BROWN

pin 8: BROWN

Side 2

pin 1: WHITE-GREEN

pin 2: GREEN

pin 3: WHITE-ORANGE

pin 4: BLUE

pin 5: WHITE-BLUE

pin 6: ORANGE

pin 7: WHITE-BROWN

pin 8: BROWN

Specific Cabling

Use of pairs

The used paires (and associated pin's) from some types of schemes:

Cabletype Used pairs Associated pin's

ATM 155Mbps pair 2 and 4 pin's 1-2, 7-8

Ethernet 10Base-T pair 2 and 3 pin's 1-2, 3-6

10/21/2010 UTP 25 pair Cable Colorcoding

www.2ics.be/technical/technicalutp.htm 7/8

Page 8: UTP 25 Pair Cable Color Coding

Ethernet 100Base-T4 pair 2 and 3 (4T+) pin's 1-2, 3-6

Ethernet 100Base-T8 pair 1,2,3 and 4 pin's 4-5, 1-2, 3-6, 7-8

Token-Ring pair 1 and 3 pin's 4-5, 3-6

TP-PMD pair 2 and 4 pin's 1-2, 7-8

100VG-AnyLAN pair 1,2,3 and 4 pin's 4-5, 1-2, 3-6, 7-8

Short explanation:

If there is stated that pairs 2 and 4 are used, there has to be read 4 wires and pin's. These pin's are mentioned per pair (ex. pin 1 and 2,

pin 7 and 8, get mentioned like 1-2, 7-8).

Usefull links:

Heldere site "Hoe maak ik en cross-kabel" Zeer goed uitgelegd, Nederlandstalig, met mooie plaatjes !!!

http://www.netspec.com/helpdesk/wiredoc.html

http://www.duxcw.com/digest/Howto/network/cable/index.htm

http://home.zonnet.nl/agoudberg/wiel.htm#Het%20opzetten%20van%20een%20file-server

http://www.linuxdocs.nl/view.php?id=28

Return to Homepage

10/21/2010 UTP 25 pair Cable Colorcoding

www.2ics.be/technical/technicalutp.htm 8/8