UVO-CLEANER

MODEL 42

INSTRUCTION MANUAL

JELIGHT COMPANY, INC. 2 Mason Irvine, CA 92618 U.S.A. Tel: (949)380-8774 Fax: (949)768-9457 E-mail: [email protected]

Page 2: UVO-CLEANER - ncnr.nist.gov · PDF filehe UVO-CLEANER, Model 42 with 6.5" x ... 11mediately deactivate the unit if ozone is detected. ... 110 TKB(BLK) 20 105 106 DRAWER INTER - LOCK

UVO-CLEANER

MODEL 42

TABLE OF CONTENTS

Introduction Page 3

Description & Assembly Page 4

Operation Page 6

Maintenance Page 7

Trouble Shooting Page 8

Specifications Page 9

Schematic Page 10

:ar-

Page 3: UVO-CLEANER - ncnr.nist.gov · PDF filehe UVO-CLEANER, Model 42 with 6.5" x ... 11mediately deactivate the unit if ozone is detected. ... 110 TKB(BLK) 20 105 106 DRAWER INTER - LOCK

INTRODUCTION

he UVO-CLEANER, Model 42 with 6.5" x 6.5" tray capacity is a very rugged unit designed to provide any years of trouble free service. The Model 42 relies on UV and ozone to clean organic from the

surfaces of items processed in the unit. An example is quartz, which is substantially transparent to UV. Due to the transparency, both sides may be cleaned simultaneously.

HANDLE

I J.-----J

WARNING:

TIM E INDICA TOR START-STOP SVITCH TIM ER SETTING KNOB-:;

POVER HIGH VOLT AGE LAMP INDICA TOR ON-OFF SVITCH

EXHUAST MEDIA INLET

LA MP ON INDICATOR

COVER

SLI DE

FUSE

RE CE PTACLE

:::>otentially fatal voltages exist within this machine. Never remove the cover while the unit is plugged in : :J an electrical outlet. :Jzone is produced by this unit; thus, appropriate ventilation must be provided for the exhaust. 11mediately deactivate the unit if ozone is detected.

-he lamp in this unit emits harmful UV radiation; under no circumstances is exposure permissible. :)ualified personnel must do servicing.

-Page 3-

Page 4: UVO-CLEANER - ncnr.nist.gov · PDF filehe UVO-CLEANER, Model 42 with 6.5" x ... 11mediately deactivate the unit if ozone is detected. ... 110 TKB(BLK) 20 105 106 DRAWER INTER - LOCK

DESCRIPTION & ASSEMBLY

- e UVO-CLEANER, Model 42 is equipped with a stainless steel cover, stainless steel : awer & base, and adjustable stainless steel cleaning tray.

9

(1) Cover (2) Air Baffle I Lamp Cover (3) Lamp Assembly (4) Ceramic Feed-Thru (5) Port Exhaust (6) Shelf (7) Media Inlet (2 pis .) (8) Base (9) Face Plate (10) Tray (11) Carrier Guides (12) Blower (optional) (13) Ozone Killer (optional)

-Page 4-

Page 5: UVO-CLEANER - ncnr.nist.gov · PDF filehe UVO-CLEANER, Model 42 with 6.5" x ... 11mediately deactivate the unit if ozone is detected. ... 110 TKB(BLK) 20 105 106 DRAWER INTER - LOCK

DESCRIPTION & ASSEMBLY (Con't)

To put the unit together, lay the lamp assembly (#3) next to the body assembly (#8) lamp side DOWN.

Connect the lamp wires to the ceramic feed-thru (#4). Be sure the terminals are parallel to the rear panel of the machine. If the terminals are at any angle, there is a possibility of shorting.

Carefully place the lamp assembly (#3), lamp side DOWN, on top of the lamp bracket.

Place baffle (#2) on top of the lamp assembly (#3) . Screw both the lamp assembly (#3) and the baffle (#2) to the lamp bracket using the #8-32 x .30 long screws provided.

While pushing the interlock switch in, place the cover on the unit. Secure the cover with the #8-32 screws.

Be sure to remove the vinyl caps from the two media inlet tubes at the rear of the machine.

-Page 5-

Page 6: UVO-CLEANER - ncnr.nist.gov · PDF filehe UVO-CLEANER, Model 42 with 6.5" x ... 11mediately deactivate the unit if ozone is detected. ... 110 TKB(BLK) 20 105 106 DRAWER INTER - LOCK

OPERATION

To operate the UVO-CLEANER, Model 42; first install the lamp assembly. Refer to Description & Assembly on Page 4. Once the main power cord is plugged into an electrical utlet, the main power switch can be turned on. The switch will light indicating power to

:he unit.

The exhaust of the Model 42 must be attached to a suitable exhaust system capable of maintaining minus 0.1 to minus 0.5 inches of water static pressure while in operation. It is recommended that a flexible metal 2-inch duct be used to attach this unit to your exhaust system; a 2-inch PVC pipe may be substituted.

Note: The flow rate of the input media should be equal to or less than that of the exhaust in order to maintain a positive flow of the media through the system. Using a greater flow ate of the input media will cause a backpressure in the unit forcing the exhaust gases to

leak into the operating environment.

Next, load the substrate onto the removable cleaning tray. The parts must be pre-cleaned since removing large amounts of contamination will take longer periods of time. Normal cleaning times should be determined through experimentation.

Adjust the side thumbscrews on the drawer to the appropriate settings for the desired height. The actual height of the tray varies according to the height of the product being cleaned. For optimum results, the surface of the parts being cleaned should be placed approximately Smm away from the bottom of the lamp.

Once the drawer is shut completely, the safety interlock switch engages. If either the drawer or the cover is removed, the safety interlock mechanism automatically shuts off the UV light. Thus, accidental exposure to harmful UV radiation is prevented.

To set the cleaning time, turn the knob to the right of the display until the desired time is indicated. Push the start/stop button too active the timer. The power indicator will light acknowledging that the lamp is receiving power, and the UV light is operating.

A clock built into the timer may be set by holding down the button with clock graphics, while turning the knob to the right of the display. It is functional all the time as long as the unit is plugged in. To display the time, when the timer is not in use, press the clock button.

When the cleaning cycle is complete, the timer will sound an audible alarm and automatically extinguish the UV lamp. The drawer can then be opened the tray removed , and the parts unloaded.

-Page 6-

Page 7: UVO-CLEANER - ncnr.nist.gov · PDF filehe UVO-CLEANER, Model 42 with 6.5" x ... 11mediately deactivate the unit if ozone is detected. ... 110 TKB(BLK) 20 105 106 DRAWER INTER - LOCK

MAINTENANCE

he maintenance of the UVO-CLEANER, Model 42 requires the user to remove and clean · e lamp assembly once every 100 hours. For optimum results, replace the lamp sssembly every 5,000 to 10,000 hours of operation.

To remove the lamp assembly, disconnect the main power cord first. Remove the screws retaining the cover, and carefully lift off. Next, loosen the top portion of the feed­. ru screws. Disconnect the lamp connectors from the feed-thrus. Remove the screws · at secure the lamp assembly in place. Carefully lift the lamp assembly out, using caution ot to break off the electrodes.

To install the new lamp assembly, disconnect the main power cord first. Remove the screws retaining the cover. Loosen the top portion of the feed-thru screws. Insert the lamp on the shelf using the provided screws. Tighten the screws to secure the lamp assembly in place. Attach the lamp connector to the appropriate feed-thru. Replace the machine cover and be sure the interlock switch is inside the cover.

WARNING:

USE EXTREME CAUTION WHEN CHANGING LAMPS. BE SURE THE PLUG IS OUT OF THE UNIT AT ALL TIME WHEN THE UNIT IS OPEN. NEVER LOOK DIRECTLY INTO THE LAMP WHEN IT IS BURNING. BE VERY CAUTIOUS NOT TO BREAK THE LAMP WHEN YOU ARE INSTALLING OR REMOVING IT. ...

- Page 7-

Page 8: UVO-CLEANER - ncnr.nist.gov · PDF filehe UVO-CLEANER, Model 42 with 6.5" x ... 11mediately deactivate the unit if ozone is detected. ... 110 TKB(BLK) 20 105 106 DRAWER INTER - LOCK

TROUBLE SHOOTING

SYMPTOM: No Power To The Unit.

Check the power cord, it could be loose or bad. Check the fuse to ensure it hasn't blown out. Check the cover interlock switch to make sure it is totally inset..

SYMPTOM: Power To The Unit But Timer does Not Function.

Check the drawer interlock switch by listening while closing and opening the drawer to make sure it is engaging properly ..

SYMPTOM: UV Indicator Does Not Light.

Check to see if the power indicator lamp is lit. Check the UV lamp assembly for breaks or any other damage ..

SYMPTOM: Ozone Is Present Outside Of The Unit During Operation.

Check the exhaust connections to make sure they are tight. Check the exhaust the unit is attached to.

- THESE PROBLEMS PERSIST OR IF THE MACHINE DOESN'T WORK, CALL THE =-ACTORY IMMEDIATELY.

-Page 8-

Page 9: UVO-CLEANER - ncnr.nist.gov · PDF filehe UVO-CLEANER, Model 42 with 6.5" x ... 11mediately deactivate the unit if ozone is detected. ... 110 TKB(BLK) 20 105 106 DRAWER INTER - LOCK

SPECIFICATIONS

Size (Max). . ......... . 9" Wide X 18" Long X 9.5" High

Power Requirements .. ... . .. 115 Volts, 60Hz., 3 Amps

Lamp Type ... . .. . . . Low Pressure Mercury Vapor Grid

Lamp Output . . 28,000 Micro Watts Per Cm 2 @ 254 Nm (From 6mm Dist.)

Tray Size . . ... .. . . . ... 6.5" X 6.5" Ozone Cleaning Area

SLIDE

ADJUST ~ ACROSS CARR IER GUIDE

DRAIJER

ON-OFF SIJITCH PDIJER LIGHT

START-STOP SIJITCH

~- ~lise. Bom (Engineering)\Controlled\Manuals\CURRENTIEQUIPMENTIUVO\Model42(L).doc

-Page 9- ·

Page 10: UVO-CLEANER - ncnr.nist.gov · PDF filehe UVO-CLEANER, Model 42 with 6.5" x ... 11mediately deactivate the unit if ozone is detected. ... 110 TKB(BLK) 20 105 106 DRAWER INTER - LOCK

4 if . ~

I • i ll .. ,, , jjil'llt •'1 ,.r IH "'r' ,, "

I ' I\U I ' II II I AI ' I I . Ill V li!~A -.. 1111 1 ~ IJ ~· ' • !II ll I IM LI ~ CON IIW L

AI~U COl\~ I lULl~ IIAL ' IIINK.II IlW' I MLt~U MJ l, LI II. I\ Nll'l 'f tf 111 1, K,-.,1 , ~ J I I UJ

" Sl AND n REVERSED R.D. LN. 3- J0- 94

I I C COUR 'o/IRES<FOR COLOR PRINTER ONLY> L.D. ""· 06-03-

TK 96089 D ADD ONE HCRE DRA\o/ER INT.LDCK SW'ITCHCS.( L.D. ..... OIH9-IHI ADD IJIRE I'C

0 6 5 3 2 TK AITKB

110 TKB(BLK) 20 105

106 DRAWER INTER - LOCK SWITCH

NC

TKA(BLK) COM~ 11 OIBLK)

DRAWER INT2 FEED THRU'S INTER-LOCK SWITCH

_r--IU')lO 1061BLK) ,../ GRID NC LAMP COMj~ POWER 107 ~ 1081BLK) SUPPLY Ad"l !---, B LMP - A

104 1::::;::;~1() INT3 l

LP1A(RD) I "'-J ~------"' ~

1;;; c; 1 o2Tsu0 I FT1 r~ 10JIBLK) l .. J QQ{E3RN) .. L ~

S1 110 " co 2041WH T)j 201(BL) N

~ 203 1~1?n1!~:) r

S2 LP1B(RD) r- "' .,. 1 G(GRN) ---~~HT) G

I ~

,.....-A../ ir--,.., B ~ m PS f-- ~ ~ LMP - B

FT-2

202 RECEPTACLE '~SHELF 104 P1

LAMP ON 200(WHT) ~ N ~ INDICA TOR LIGHT POWER

ON/OFF SWITCH 100(BLK) I L L1 \~ 1103(BLK)

2 10418 K)J cjtcj ('IW ~~Q2(WHD f-A f- 8 '----

SW1 G(GRN)

203(WHT)

COVER G(GRN) 107(BLK) INTER-LOCK SWITCH CHASSIS FUSE --3 AMP NC GROUND -

101 A 7'\..FIB 102(BLK) COM r-"~101 100

INT1 U:rligqf Oo. Xn c. LM.ESS OMRWISE SPEOf£0

F1 D!WEH90NS ARE IN NOf£5 1\liWNC<S

2 MASON, IRVINE, CA 92618 ""'"" IWJUR

101 (BLK) , """ ± 1/Z MODEL 42 & 342, UVO CLEANER ,lO( ±.01 .XXX *-"" SCHEMATIC

NOTE•

/ I . SIZE I PjN I REV !. COLOR MAGENTA REPRESENT \o/HITE \o/IRE CHECKED I D 70-01 11 D 2. USING FOR ENGINEER K.V/, 1 3-19-93

MODEL 42 APPR I NEXT ASSYo MODEL 42 - 100

QTY•======== I SCALE 1 1 1 SHEET 1 OF 1 MODEL 342

Page 11: UVO-CLEANER - ncnr.nist.gov · PDF filehe UVO-CLEANER, Model 42 with 6.5" x ... 11mediately deactivate the unit if ozone is detected. ... 110 TKB(BLK) 20 105 106 DRAWER INTER - LOCK

Jelight Company, Inc. 2 Mason, Irvine, CA 92618 PHONE: (714) 380-8774 • FAX: (714) 768-9457

MATERIAL SAFETY DATA SHEET LOW PRESSURE MERCURY VAPOR LAMPS

: x pressure mercury vapor lamps manufactured by Jelight Company, Inc. are exempted from the -"" ments ofthe OSHA Hazard Communication Standard (29 CFR 1910.1200) because they are articles. ·:::- llowing information is provided by Jelight Company, Inc. as a courtesy to its customers.

PRODUCT IDENTIFICATION Trade Name (as labeled) Low Pressure Mercury Lamps (Ultraviolet Lamps)

Manufacturer JELIGHT COMPANY, INC. 2 Mason, Irvine, CA 92618 Tel : (714) 380-8774 Fax: (714) 768-9457

HAZARDOUS INGREDIENTS THERE ARE NO KNOWN HEALTH HAZARDS FROM EXPOSURE TO LAMP MATERIALS THAT ARE INTACT. If the lamp is broken, the following materials may be released.

Exposure Limits in Air (mg/cubic m.) Chemical N arne Quartz (Silica)

Mercury

CAS Number %by wt. AGClli (TLV) OSHA (PEL) 60676-86-0 80 0.8 0.1 7439-97-6

PHYSICAL PROPERTIES:

FIRE & EXPLOSION HAZARDS

Flammability Fire Extinguishing Materials Special Firefighting Procedure

Unusual Fire and Explosion Hazard

< 0.05 0.025 0.1 Ceiling

Not applicable to intact lamp.

Non-combustible Use extinguishing agents suitable for surrounding fire Use a self-contained breathing apparatus to prevent inhalation of dust and/or fumes that may be generated from broken lamps during fire-fighting activities. When exposed to high temperature, toxic fumes may be released from broken lamps.

HEATH HAZARDS THERE ARE NO KNOWN HEALTH HAZARDS FROM EXPOSURE TO LAMP MATERIALS THAT ARE INTACT.

See additional bulletin on health hazards and safety related to lamp operation. No adverse effects are expected from occasional exposure to broken lamps. As a matter of good practice, avoid prolonged or frequent exposure to broken lamps unless there is adequate ventilation. The major hazard from broken lamps is the possibility of sustaining glass cuts.

Jelight Company, Inc. 1 of 3

Page 12: UVO-CLEANER - ncnr.nist.gov · PDF filehe UVO-CLEANER, Model 42 with 6.5" x ... 11mediately deactivate the unit if ozone is detected. ... 110 TKB(BLK) 20 105 106 DRAWER INTER - LOCK

::: FFECTS OF OVEREXPOSURE TO BROKEN LAMPS BY INHALATION INGESTION OR : ONTACT WITH SKIN OR EYE .

. 1ercury Exposure to high concentrations of vapors for brief periods can cause acute symptoms such as pneumonitis, chest pains, shortness of breath, coughing gingivitis, salivation, and possibly stomatitis. Chronic exposure may cause tremors and neuropsychiatric problems. May cause redness and irritation as a result of contact with skin and/or eyes.

~uartz Inhalation

Ingestion

Skin contact

Eye contact

Chronic excessive exposures to fused silica dust may produce lung injury. Fused silica appears amorphous when subjected to x-ray diffraction, but one report suggests it may contain micro-crystals of quartz and could be fibrogenic. Prolonged excessive exposure to the condensed vapors reportedly can produce transient pulmonary lesions which are reversible upon cessation of exposure. Although the evidence is limited and cont1icting, crystalline silica is listed by IARC as possible human carcinogen. The status of fused silica has not been determined.

No adverse effects anticipated since material is insoluble and non-toxic.

No adverse effects anticipated.

Irritation due to mechanical abrasion.

EMERGENCY AND FIRST AID PROCEDURES

Glass cuts Perform normal first aid procedures. Seek medical attention as required.

Inhalation If discomfort, irritation or symptoms of pulmonary involvement develop, remove form exposure and seek medical attention.

Contact Skin Thoroughly wash affected area with mild soap or detergent and water and prevent further contact. Seek medical attention if irritation occurs.

Contact Eye Wash eyes, including under eyelids immediately with copious amounts of water for 15 minutes. Seek medical attention.

REACTIVITY DATA

Stability Conditions to avoid Incompatibility (materials to avoid) Hazardous Decomposition Products (including combustion products) Hazardous Polymerization Products

Jelight Company, Inc. 2 of 3

Stable None for intact lamps Dissolves in hydroflouric acid. None for intact lamps Will not occur

-- -----·-----------~

Page 13: UVO-CLEANER - ncnr.nist.gov · PDF filehe UVO-CLEANER, Model 42 with 6.5" x ... 11mediately deactivate the unit if ozone is detected. ... 110 TKB(BLK) 20 105 106 DRAWER INTER - LOCK

J. PROCEDURES FOR DISPOSAL OF LAMPS

If lamps are broken, ventilate area where breakage occurred. Clean up with mercury vacuum cleaner o~ other suitable means that avoid dust and mercury vapor generation. Take usual precautions for collection of broken quartz. Clean up requires special care due to mercury droplet proliferation. Place materials in closed containers to avoid generation dust. It is the responsibility of the waste generator to ensure proper classification of waste products To that end, TCLP tests should be conducted on all waste products, including this one, to determine the ultim ate di sposition in accordance with applicable federal, state, and local regulations .

SPECIAL HANDLING INFORMATION -FOR BROKEN LAMPS

Ventilation

Respiratory Protection

Eye Protection

Protective Clothing

Hygiene Practices

Use adequate general and local exhaust ventilation to maintain exposure levels below PEL or TL V limits. If such ventilation is unavailable, use respirators as specified below

Use appropriate NIOSH approved respirator if airborne dust Concentrations exceed the pertinent PEL or TL V limits. All Appropriate requirements set forth in 29 CFR 1910.134 should be met.

OSHA specified safety glasses, goggles or face shield are recommended iflamps are being broken

OSHA specified gloves are recommended for dealing with broken lamps.

After handling broken lamps, wash thoroughly before eating, smoking or using toilet facilities.

~ I though JELIGHT CO .NIP ANY, INC. attempts to provide current and accurate information herein, it makes no - ~presentations regarding the accuracy or completeness of the information and assumes no liability for any loss, :amage, or injury of any kind which may result from, or arise out of, the use of/or reliance on the information ·y any person.

~ssued Date: April 28, 1995

Jelight Company, Inc. 3 of 3