Page 1: V1800BPMUserManual VitalSignsMonitor ForAnimals

V1800BPM User Manual

Vital Signs MonitorFor Animals

Page 2: V1800BPMUserManual VitalSignsMonitor ForAnimals

V1800BPMUSER MANUAL

2

The information in this manual is for reference only and is subject to changewithout notice and shall not be regarded as a commitment made by Vet1 Pty Ltd.are not responsible for possible errors or inaccuracies in this manual.

V1800BPM vital signs monitor is a clinical blood pressure automatic monitor, whichis specially developed for animal blood pressure measurement. The subsequentupgrade will increase the function of pulse oxygen saturation and temperaturemeasurement. The blood pressure cuff is tied to the pet's forelimb or tail.Portabledevices are available in pet hospitals, which can be used for dynamic monitoringof blood pressure, continuous monitoring and testing of different animal ID

V1800BPM is a portable device that is lightweight and supports touch andkeystroke operation. The device is powered by a single rechargeable lithium ionbattery or four batteries at the bottom of the device.All parameters in the devicecan set the highest and lowest alarm limits.

Page 3: V1800BPMUserManual VitalSignsMonitor ForAnimals

3

Contents

1. Icons and symbols ........................................................................................................... 42. Vital signs monitor ........................................................................................................52.1 Appearance............................................................................................................................ 52.2 Connection Interface ............................................................................................................ 52.3 Screen display ........................................................................................................................ 72.4 Start/stop button....................................................................................................................83. System functions........................................................................................................... 93.1 Animal Model Selection........................................................................................................ 93.2 Volume ................................................................................................................................... 93.3 Settings ................................................................................................................................... 93.4 Work model...........................................................................................................................103.5 User settings .........................................................................................................................113.6 Alarm settings .......................................................................................................................113.7 Blood pressure settings.......................................................................................................123.8 System settings.....................................................................................................................133.9 Data review ...........................................................................................................................144. Blood pressure measurements..................................................................................... 174.1 Sleeve use..............................................................................................................................174.2 Blood pressure measurements ..........................................................................................174.3 Interval measurement mode ..............................................................................................174.4 STAT mode (continuous measurement mode).................................................................184. Alarm.............................................................................................................................. 194.1 Technical alarm.....................................................................................................................194.2 Physiological alarm...............................................................................................................205. Technical information.................................................................................................... 215.1 Product model ......................................................................................................................215.2 Performance indicators .......................................................................................................217. Frequently asked questions .......................................................................................... 22

V1800BPMUSER MANUAL

Page 4: V1800BPMUserManual VitalSignsMonitor ForAnimals

4

1.Icons and symbols

Access the Settings screen

Small animal model

Large animal model

Open the icon menu

Start interval blood pressuremeasurement pattern

Adjust the volume

View data

Exit menu

Return to Upper menu

Delete all stored memory data

Mean selected blood pressurevalues

Begin STAT mode

Bluetooth

On/off/start/stop blood pressuremeasurements

Battery power indicator

Symbol Details

V1800BPMUSER MANUAL

Page 5: V1800BPMUserManual VitalSignsMonitor ForAnimals

5

2.Vital signs monitor2.1 Appearance

2.2 Connection Interface

1. Power adapter interface

Set buttonGo to Settings menu

Power buttonShort press boot, longpress 2 seconds shutdown;when boot, short pressmeasurement or stopmeasurement.

Animal mode switch keySwitch size animal mode.

V1800BPMUSER MANUAL

Page 6: V1800BPMUserManual VitalSignsMonitor ForAnimals

6

Insert the AC adapter plug into the v1800bpm monitor, then plug theother end of the AC adapter into the power supply to charge the battery,and only use the AC adapter provided by our company, only use the ACadapter when using lithium battery power supply.

2. Blood pressure cuff interface

Connect the pet hose to the back of the monitor and make surethe connector is connected to the correct position.

V1800BPMUSER MANUAL

Page 7: V1800BPMUserManual VitalSignsMonitor ForAnimals

7

2.3 Screen display

The monitor boot will display the measurement interface. Here is a quick previewof the key symbols and values you will see.

Icon menu

V1800BPMUSER MANUAL

Page 8: V1800BPMUserManual VitalSignsMonitor ForAnimals

8

When you press the "menu" button on the main interface, you will open the "iconmenu ". You can view the device's functional settings by icon indication. duringblood pressure measurement, do not access the "icon menu ".

1. Exit icon menu2. Settings3. Animal selection4. Speaker volume5. Storage list6. STAT mode (continuous measurement mode)7. Interval blood pressure measurement pattern8. Bluetooth

2.4 Start/stop button

Button indicates the status of the v1800bpm monitor, shutdown charge, red light,full power, green light.Turn it on,Equipment normal green light, alarm red light

flashing, boot charging state, battery icon prompt.

1. In shutdown state, short press the button to boot, boot time by two secondsshutdown.

2. During the blood pressure reading, press the button to measure the bloodpressure and stop the measurement again.

3. Screen for touch screen, touch blood pressure measurement area can startor stop measurement.The area shown below.

4. Error, prompt status information, will appear prompt warning.

V1800BPMUSER MANUAL

Page 9: V1800BPMUserManual VitalSignsMonitor ForAnimals

9

3.System functions3.1 Animal Model Selection

Select small animal mode, use #4 below specification cuff, suitable formeasuring small animals (<8 kg), such as cats and dogs.

Select large animal model, use #5 and above cuff, suitable for measuring largeanimal (>8 kg) dogs.

If animal mode does not match, touch the main interface "size animal button" orshortcut key button to switch.

(size animal button) (shortcut key)

3.2 Volume

v1800bpm default settings for speakers in the monitor are off to avoid petsbeingdisturbed by sound. Switch between speaker off, bass and treble, press thevolume button to switch.

(Volume)

3.3 Settings

to access the settings interface, select the settings button () in the menu.

V1800BPMUSER MANUAL

Page 10: V1800BPMUserManual VitalSignsMonitor ForAnimals

10

3.4 Work model

v1800bpm support (Spot) multi-user measurement mode or (Monitor)monitoringmode.

● Spot support up to 100 ID number management (0-99), each I D supports200 sets of data storage, suitable for different animal temporarymeasurement management. When power saving mode is turned on ,10minutes without measurement will automatically sleep

● Monitor only support single user management, support up to 1000 groups ofdata storage, suitable for continuous monitoring management.

Work modelMultiple user orguardianshipoption

User settingsOptional or user

Alarm settingsSet alarm upperand lower limits

Blood pressuresettingsSet blood pressureparameters

System settingsSet systemparameters

Data reviewYou can viewhistorical data listsand trend charts

V1800BPMUSER MANUAL

Page 11: V1800BPMUserManual VitalSignsMonitor ForAnimals

11

3.5 User settings

(Spot mode) (Monitor mode)

● User selection● Increased number of users● Delete users

3.6 Alarm settings

v1800bpm monitor allows clinical alarm signals for all values (systolic, diastolic,pulse rate) to be sent.● to change the alarm value, select the settings interface in the icon menu and then

select "alarm settings ".● Click touch the parameters to set, and then the settings interface pops up.● The left number is the minimum value that can be set, and the right number is the

maximum value that can be set. The white progress bar indicates thatThe upper and lower limits of the area of the total range.

● The minimum value of upper limit setting should not be lower than the lower limit,and the maximum value of lower limit should not be set higher than that of upperlimit setting.

● Click on the number to enter the set value, click on the OK can.● When triggering the alarm, the value beyond the set range will be prompted

to exceed the range on the main interface. If the speaker is turned on, aprompt will be issued.see section 10 for more information on alarms.

V1800BPMUSER MANUAL

Page 12: V1800BPMUserManual VitalSignsMonitor ForAnimals

12

SYS upper and lower limit range :40 mmHg ~280 mmHg

DIA upper and lower limit range :10 mmHg ~220 mmHg

Pulse rate upper and lower limit setting range :25 bpm ~500 bpm

3.7 Blood pressure settings

1. Measurement mode: Manual( manual), Auto( automatic),Stat( continuous).

2. Sleeve type: small cuff mode (small animal), large cuff mode (largeanimal).

V1800BPMUSER MANUAL

Page 13: V1800BPMUserManual VitalSignsMonitor ForAnimals

13

3. Pressure unit: mmHg( mmHg), KPA.4. measurement interval: measurement interval Auto( automaticmode), the interval time can be set 1,2,3,4,5,10,15,30,60 and 90 minutes.

3.8 System settings

Select System Settings from the Settings menu and pop up the following menu:

● Energy saving mode: On, SPOT mode will automatically sleep.Close, do not sleep in SPOT mode.

Note: energy saving mode does not work on monitoring mode.● Bluetooth: Bluetooth switch.● Brightness Options: Level 1, Level 2, Level 3, Level 4● "Alarm Volume" optional: Level 0, Level 1, Level 2, Level 3.● Time: Time adjustment.● "Equipment Maintenance ": Only for developers.● Device Information: Device Version Number.● Restore factory settings: in addition to language settings, other functions

restore default factory setting

V1800BPMUSER MANUAL

Page 14: V1800BPMUserManual VitalSignsMonitor ForAnimals

14

3.9 Data review

1. Select data Review in the Settings menu or in the icon menu to enter thehistorical data view interface.

For example, in Monitor mode:

Data review has a blood pressure list and blood pressure trend chart to see:

V1800BPMUSER MANUAL

Page 15: V1800BPMUserManual VitalSignsMonitor ForAnimals

15

The trend chart shows systolic blood pressure, diastolic blood pressure, pulse rate,different color differences, the vertical axis on the left represents pressure, and thevertical axis on the right represents pulse rate, where the red line represents the SYS,blue line represents DIA, the green line represents the PR. The following horizontal axisshows the time, the trend also includes ID, pages, Date( the time range of this pagedata), by turning over the page to preview all the data.

Blood pressure lists show measurements including time, SYS,DIA,MAP,PR, andaverage calculations,AVGAVG When we click will enter the average calculation interface, select the data results ofthe average we want to calculate.Delete icon, when we click the delete icon to select the data results we want to delete.Each page displays 11 groups of data, looking at all the data through the page.

V1800BPMUSER MANUAL

Page 16: V1800BPMUserManual VitalSignsMonitor ForAnimals

16

2. View Average Data

In the data list, blood pressure data can be averaged.AVGClick on theidentifier "to select the row you want to calculate the average value, showingthe average value of the selected measurement result

Average of selected data

3. Delete dataIn the data list, clicking on the identifier Delete data will delete all blood pressure dataunder the user.

Delete all memory data

V1800BPMUSER MANUAL

Page 17: V1800BPMUserManual VitalSignsMonitor ForAnimals

17

4.Blood pressure measurements4.1 Sleeve use

v1800bpm monitor is equipped with different sizes of blood pressure cuff. Each cuffcontains important marks, which helps to select the correct cuff size, measure thecircumference of the limb, and select the cuff with a width of 40% of the dog'scircumference and 30% of the cat's circumference.When the cuff is too small, theblood pressure is too high.

It is recommended that the cuff be placed on the forelimb when the pet lies onthe right or left. This helps ensure that the cuff is at the same level as the heart,and the measurement accuracy is the highest. In addition, pets are less likely toretract their forelimbs when the cuff is gently squeezed during measurement. Thecuff should be placed in a position to align its arterial markings with the limbartery.

If the pet looks comfortable, fix the cuff and hold the limb during blood pressuremeasurement. This will help keep the cuff at the same level as the heart andrelax the pet's muscles. If the pet is anxious enough to bite or scratch the cuff orstand, the base of the tail is a good fixed position.

4.2 Blood pressure measurements

1. Fix pet position, lie down, sit down or lie down. Place the cuff on the limb toensure that it is not placed on the joint. The cuff is a sensor to ensure thatthe cuff is close to the pet skin to provide a better signal for the monitor.Connect the cuff hose to the monitor hose.

2. Select animal type according to animal weight or cuff type.3. Press the start / stop button or click in the blood pressure measurement data

screen area to start the blood pressure measurement. After the measurement iscompleted, the measurement results are displayed.

4. During the measurement, start / stop button or click in the blood pressuremeasurement data screen area to stop the measurement.

Tip: during blood pressure readings, the icon menu is not available. to access the iconmenu, wait until the blood pressure reading is complete or press the start/stop buttonto stop the reading.Tip: it is recommended that animals be measured after 5 minutes of quiet.

4.3 Interval measurement mode

During the blood pressure interval measurement mode, the v1800bpm monitorautomatically measures the blood pressure value according to the set timeinterval.The interval can be modified by the interval blood pressure setting function.

V1800BPMUSER MANUAL

Page 18: V1800BPMUserManual VitalSignsMonitor ForAnimals

18

Tip: in interval measurement, blood pressure measurement can be startedmanually. If the measurement is stopped during the measurement, theequipment will exit the interval measurement mode and enter the manualmeasurement mode

4.4 STAT mode (continuous measurement mode)

v1800bpm monitor will automatically continuously measure blood pressure in STATmode.

Tip: in STAT mode, when the equipment does not start measuring bloodpressure, it can start the blood pressure measurement manually. If themeasurement is stopped during the measurement process, the equipmentwill exit the interval measurement mode and enter the manual measurementmode

Intervalmeasurementmode, thefollowing numberrepresents theinterval time.

STAT mode

V1800BPMUSER MANUAL

Page 19: V1800BPMUserManual VitalSignsMonitor ForAnimals

19

4.Alarm4.1 Technical alarm

Technical alarm occurs when errors occur during blood pressure measurement.

During the alarm, sound will be made, and the bomb window warningfailure.Invalid vital signs will not be displayed.

Alarm Reasons SolutionsAirleakage

Sleeve, hose ormain engineleaking, or cuff /hose notconnected tomain engine

Check that the hose is connected tothe monitor and cuff.Check that the cuff is fastenedcorrectly.Check that the cuff is in the correctposition.Check the cuff for air leakage.Check hose connections fordamage or loosening

BeyondScope

Blood pressureexceedsv1800bpmmonitoring

Make sure the cuff size is correct.Pets may be too active.

Weak signal The monitor did notreceive a pet signal

Check that the cuff is in the correctposition.Check the patient.Check that the cuff is fastenedcorrectly.Check if the correct size cuff isused.

Excessiveexercise

The monitor isreceiving suddennoise or operating

Check the animal's mode and mayset an error.Check the pet's behavior fortrembling or excessive activity.Check that the cuff is in the correctposition.Check that pets move or tremble.

Too long The instrument did notdetect strong andcontinuous signalsfrom pets for a longtime

Check to ensure that the cuff isattached to the pet and is properlypositioned.Check that the cuff is in the correctposition.Check that pets move or tremble.

Too low Insufficient batterypower

Charge or replace batteries

Wrong cuff,wrongpressure

Air can not passthrough hose or cuffproperly.

Check to ensure that the hose is notbent and not squeezed.Check that the pet is lying orstepping on the cuff.

V1800BPMUSER MANUAL

Page 20: V1800BPMUserManual VitalSignsMonitor ForAnimals

20

Check that the cuff size is correct.Check that the cuff is in the correctposition.

Overpressureprotection

Because of petmovement, airblockage or use of toosmall cuff, the cuffpressure brieflyexceeds 300 mmHg.

Check the suitable cuff band for themodel being used.Check to ensure that the hose is notbent and not squeezed.Check that the pet is lying orstepping on the cuff.Ensure that pets are not overactive

System error Hardware problems orabnormal cuffpressure when boot.

Disconnect the cuff from the deviceand reboot.If can not solve the need formaintenance.

4.2 Physiological alarm

Physiological alarm occurs when the measured value reaches or exceeds thehigh or low limit set by this parameter. When blood pressure clinical alarm occurs,there will be a red warning, and intermittent drops.

V1800BPMUSER MANUAL

Page 21: V1800BPMUserManual VitalSignsMonitor ForAnimals

21

5.Technical information5.1 Product model

Model Model Description

v1800bpm

Single blood pressure

5.2 Performance indicators

Blood pressure performance

Method ofmeasurement

Schematic method

Blood pressurerange:

SYS:40–270mmHg

DIA: 20-230 mmHgMEAN:10–200mmHg

Pulse rate range: BPM 40-240Sensor accuracy: (0 mmHg -300mmHg )±3 mmHg

OtherNote: if the machine is used or stored outside the specified temperature and humidityrange, its performance will be affected.

Conditions of use: °C to 50°C C ,15% to 90% humidity, no condensationStorage conditions: -20°C to 65°C C ,15% to 90% humidity, no condensationHeight: Measurement accuracy is not affected by heightPower: Lithium ion batteries and/or AC adaptersInput voltage range: Universal (100 to 240 V AC)Input frequencyrange:

General purpose (50-60 Hz)

Adapter output: DC:9 V-2ALithium batteries: 7.4 V,2.6Ah ,19.24WhSize: 15.9 cm x 12.7cm x 13.3cmWeight: 0.95 Kg with battery

V1800BPMUSER MANUAL

Page 22: V1800BPMUserManual VitalSignsMonitor ForAnimals

22

7.Frequently asked questions

How many measurements can be stored in memory?

SPOT mode, each ID number can store 200 measurement data.When the 201thmeasurement is carried out, the monitor automatically covers the firstmeasurement.When the creation ID is full, the user needs to manually delete theprevious ID number to create a new ID number.Monitor mode, up to 1000 measurements can be stored. The monitor has a loopmemory. In the 1001 measurement, the monitor automatically covers the firstmeasurement.

For medium-sized dogs, which animal model should I choose?

Judge according to the size of the cuff used. If the most suitable cuff used is #3 orsmaller, select small animal mode. Select large animal mode if the most suitablecuff is #4 cuff or larger cuff.

How to choose the correct cuff size?

Wrap the cuff around the pet's limbs to ensure that the scale is within the markedrange. If there are two different cuff sizes that match the pet, choose a larger size.

How long can the battery last?

Continuous monitoring SpO The interval between blood pressure measurementsis set to5 Minutes, charged batteries should last for at least 4 hours beforecharging. if only manual BP measurements are performed, the fully chargedbattery shall continue to perform at least 150 BP measurements beforerecharging. Battery charge takes more than 6 hours. The battery life depends toa large extent on the time when the touch screen is displayed as open. In orderto prolong the battery life as much as possible, it is recommended to turn onautomatic shutdown.

Can this monitor be used in awake and anaesthetic animals?

Yes.V1800BPM vital signs monitor can be used in anesthetized and awake animals.

How to prevent the cuff from sliding down or falling off?

Tie the cuff as tightly as possible. Special attention must be paid to the density orthickness of species fur. If the cuff is not fastened, check the fur magic stick and,if possible, tear off the magic stick.

V1800BPMUSER MANUAL

Page 23: V1800BPMUserManual VitalSignsMonitor ForAnimals

23

Any other power options?

Yes. The device is equipped with a main power supply, connected to the built-inbattery charge. When the device is not connected to the power supply, the batteryallows the device to be portable for use.

How much is the minimum and maximum weight of cats and dogs

when using V1800BPM monitors for blood pressure measurements?

There are no restrictions. Any cat or dog with a suitable cuff range limb isapplicable.

Warranty time

Mainframe 1 year, blood pressure hose 3 months.

V1800BPMUSER MANUAL