va-ah015-说明书-英文-20170914-v1.3-网络版 · ② the unit will resume working once water is...

2
VAVA ULTRASONIC HUMIDIFIER User Guide MIST HUMIDITY TIMER SLEEP ON / OFF 11 12 13 Product Diagram 1. Rotatable Nozzles 2. Water Tank 3. Power Cord 4. Humidity Sensor 5. Base 6. LED Display 7. Power Button 8. Sleep Button 9. Mist Button 10. Humidity Button 11. Timer Button 12. Air Inlet 13. Drain Side Specifications Model Operating Voltage Power Water Tank Capacity Mist Output VA-AH015 US / CA: AC 120V 60Hz UK: AC 230V 50Hz 26W (High Mist) 21W (Medium Mist) 17W (Low Mist) 5 L / 172.4 oz 350mL / hour (High Mist) 250mL / hour (Medium Mist) 150mL / hour (Low Mist) How to Use WATER Adding Water Tank Cap Tank Inlet Rotate the tank cap counterclockwise to loosen it, add an appropriate amount of water into the tank, and screw the cap clockwise to fasten it until no water leaks. Do not rotate with excessive force.

Upload: others

Post on 08-Oct-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: VA-AH015-说明书-英文-20170914-v1.3-网络版 · ② The unit will resume working once water is added or the tank is placed back on the base. Title: VA-AH015-说明书-英文-20170914-v1.3-网络版

VAVA ULTRASONIC HUMIDIFIER

User Guide

MIST

HUMIDITY

TIMER

SLEEP

ON / OFF

⑦⑧

⑨⑩11

12

13

Product Diagram1. Rotatable Nozzles

2. Water Tank

3. Power Cord

4. Humidity Sensor

5. Base

6. LED Display

7. Power Button

8. Sleep Button

9. Mist Button

10. Humidity Button

11. Timer Button

12. Air Inlet

13. Drain Side

Specifications

Model

Operating Voltage

Power

Water Tank Capacity

Mist Output

VA-AH015

US / CA: AC 120V 60Hz UK: AC 230V 50Hz26W (High Mist)21W (Medium Mist)17W (Low Mist)

5 L / 172.4 oz

350mL / hour (High Mist)250mL / hour (Medium Mist)150mL / hour (Low Mist)

How to UseWATER

①②

Adding Water ① Tank Cap

② Tank Inlet

Rotate the tank cap counterclockwise to loosen it, add an appropriate amount of water

into the tank, and screw the cap clockwise to fasten it until no water leaks. Do not rotate

with excessive force.

Page 2: VA-AH015-说明书-英文-20170914-v1.3-网络版 · ② The unit will resume working once water is added or the tank is placed back on the base. Title: VA-AH015-说明书-英文-20170914-v1.3-网络版

VA-AH015

www.vava.com

Learn more about the EU Declaration of Conformity: https://www.vava.com/downloads-VA-AH015-CE-Cert.html

E-mail: [email protected]: 1-888-456-8468 (Monday-Friday: 9:00 – 17:00 PST)

Address: 46724 Lakeview Blvd, Fremont, CA 94538

NORTH AMERICA

EUROPEE-mail: [email protected](UK)[email protected](DE)[email protected](FR)[email protected](ES)[email protected](IT)EU Importer: ZBT International Trading GmbH, Halstenbeker Weg 98C, 25462 Rellingen, Deutschland

MANUFACTURERShenzhen NearbyExpress Technology Development Company Limited Address: 333 Bulong Road, Jialianda Industrial Park, Building 1,Bantian, Longgang District, Shenzhen, China, 518129

Note:

1. Remove the nozzle before you uplift the water tank, and put it back on when the water

tank is placed onto the base after the water has been added.

2. When you fail to open the tank cap, wipe the cap dry and rotate it with proper force.

Operation and FunctionsAdd water into the tank, connect to a power source, the unit is now in standby mode.

Note: The buttons on the control panel are the same as those on the remote control.

(1)Power On / Off

① In standby mode, tap the Power Button once to enter Level 2 Misting by default and a

beep sound will be heard. The LED display will show the mist level, environmental RH, and

temperature.

② Tap it again to power off the misting, and a beep sound will be heard. The LED display

shows the RH and temperature only.

(2)Mist Adjustment

The mist level can be adjusted from 1 ~ 3 levels with a tap of the Mist Button. A beep sound

will be heard with each tap and the LED display will show the corresponding mist level.

(3)Humidity Setting

① Tap the Humidity Button once to activate continuous misting and the “CO” icon on the

Display flashes 3 times. Before the flashing ends, you can set the humidity level from 30%

to 95% through the Humidity Button by 5 with each tap. When set, the corresponding

humidity value will flash 3 times to confirm the setting and the humidity icon will keep

flashing.

Note: The misting works normally if the set humidity on the unit is higher than the RH and

stops if the set humidity is lower than the RH.

② After the humidity is set, tap and hold the Humidity Button for 1.5 seconds to exit the

setting, the LED display will flash “CO” 3 times. The humidity icon will disappear.

③ When the humidity is set, the Mist Button remains responsive.

(4)Timer Setting

① Tap the Timer Button once, the LED display will show “--H” and flash 3 times. Before the

flashing ends, set the timer from 1 to 12 hours by tapping the Timer Button. The

corresponding timer will show on the LED Display and flash 3 times to conf irm the setting.

② When the timer is set, tap and hold the Timer Button for 1.5 seconds to exit the setting.

The LED display will show “—H”which will disappear after flashing 3 times.

③ A beep sound will be heard each time you tap the Timer Button.

(5)Sleep Mode

① Tap the Sleep Button once to enter sleep mode. All icons on the LED display (except the

sleep icon) will turn off. In sleep mode, the Mist Button, Humidity Button, and Timer Button

remain functional, but the beep sound is disabled.

② In sleep mode, tap the Power Button to turn off the unit. Tap the Sleep Button to exit

sleep mode, the sleep mode icon will disappear.

(6)Memory Function

With power connected, the unit will resume the humidity setting selected the last time it

has been turned off (the humidity setting icon will not be shown on the LED display). The

timer and sleep mode settings will be cleared.

(7)Water Tank Light

The water tank light will turn on / off with the power.

(8)Low Water or Water Tank Removal Protection

① When water in the tank is depleted or the water tank is removed, the unit will stop

working and the water shortage icon will appear on the LED display.