vacuum control valves - smc pneumatics · va01 vacuum control valves for centralized vacuum systems...
TRANSCRIPT
Pneumatic1 Parker Hannifin Corporation
Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
D
VacuumControl Valves
Section DD
pneu
air
e
Pneumatic2 Parker Hannifin Corporation
Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Catalog 0802-2/USA
NotesVacuum Control Valves
pneu
air
e
Pneumatic3 Parker Hannifin Corporation
Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
D
Catalog 0802-2/USA
Index
VA01 Vacuum Control Valves for Centralized Vacuum Systems
VA01PSV23 & VA01PSP23, 3-Port, 2-PositionFeatures & Specifications............................................................................ 4Model Number Index ................................................................................... 5Accessories ................................................................................................. 6Dimensions ................................................................................................. 7
VA01RDP33, 3-Port, 3-PositionFeatures & Specifications............................................................................ 8Model Number Index ................................................................................... 9Accessories ................................................................................................10Dimensions ................................................................................................11
VA01PEP34, 4-Port, 3-PositionFeatures & Specifications...........................................................................12Model Number Index ..................................................................................13Accessories ................................................................................................14Dimensions ................................................................................................15
FSV Flow Sensing ValveMetered Flow Sensing Valve..................................................................... 16-17
CH01 Check ValveOne Way Check Valve for Vacuum Applications..............................................18
Vacuum Control Valves
pneu
air
e
Pneumatic4 Parker Hannifin Corporation
Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Catalog 0802-2/USA
Features & SpecificationsSolenoid Valves for VacuumVA01 Series
PSV23
PSP23
Features• Lightweight, Compact, Direct Acting,
10mm Wide Solenoid Valve
• PSV23 Normally Closed, 3-Way forCentralized Vacuum Systems
• PSP23 Normally Closed, 3-Way forBlow-off Control
• Vacuum Leakage is Reduced to LessThan .6 inHg / min (At 26.5 inHg,1.22 cu. in.)
• 5 ms Response Time
• Manifolds up to 20 Stations areAvailable
For VacuumControl
For Blow-off Control(Positive Pressure)
ApplicationsThe PSV23 valve can be used for vacuum applicationswhere a central vacuum system is used for creatingthe negative pressure for vacuum. The 10mm widevalve can be mounted on a single subbase for point ofuse applications or manifolds for a centralized control.As shown, the single subbase can be used to mountthe valve and vacuum cup together reducing overallmounting space.
The PSP23 valve can be used for positive pressureapplications up to 72.5 PSI. This valve can be used forblow-off functions to break the vacuum pressure.
Applying positive pressure to PSV23 or negativepressure to PSP23 will cause air leakage oroperational failure.
2
31
1: Positive Pressure Port2: Output Port3: Exhaust Port
PSP232
31
1: Vacuum Supply Port2: Output Port3: Atmospheric Release Port
PSV23
2
3
1
PCG Cup
pneu
air
e
Pneumatic5 Parker Hannifin Corporation
Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
D
Catalog 0802-2/USA
Ordering InformationSolenoid Valves for VacuumVA01 Series
VA01 PSV 23 1 PE
Valve Type
PSV Negative (Vacuum)Pressure Valve Only
PSP Positive Pressure,Valve Only
Operator Function
23 Single Solenoid,3-Way, NC
Valve Model Number IndexBold Items Are Stocked
Wiring Type
PE* Plug-in Connector(With Indicator Light& Surge Protector
L 500mm Lead Wire(Without IndicatorLight & Surge Protector
* Includes 500mm Connector
MFS 06 V01 V3 CC M5
Number ofStations
02 2-Station
04 4-Station
06 6-Station
08 8-Station
10 10-Station
Manifold Model Number IndexBold Items Are Standard
Note: Valve manifolds available up to 20 stations and in odd or evennumbers. Consult Factory for availabilty.
Note: Valve includes Gasket & Mounting Screws.
SpecificationsModel Number VA01PSV23 VA01PSP23
Media AirPort Size M5 Female
FlowVacuum .78 [email protected] inHg —
Vacuum Break — 1.4 [email protected] PSIPressure Range 0 to 29.5 inHg 0 to 72.5 PSIProof Pressure .3 mPa (43.5 PSI) .75 mPa (108.7 PSI)
Ambient Temperature 14 to 122°F (-10 to 50°C) Response Time
ON 5 ms or LessOff 5 (10) ms or Less
Rated Voltage 24VDCPermissable Voltage
± 10%FluctuationHeat Resistance Grade Grade B
Power Consumption 2WWiring Lead Wire, Connector with Lead Wire
Vibration Resistance 150 m/s2
Shock Resistance 50 m/s2
Mass .88 oz. (25 g.)
Note: When using the valve for vacuum break at less than 41°F (5°C) bysupplying compressed air, use dry air passing through an air dryerto prevent dew condensation and freezing.Response time in bracket () shows with surge suppressor.
Type of MountableValve
V3 PSV23 orPSP23*
* PSV23 & PSP23 cannot be used togetheron the same manifold.pneu
air
e
Pneumatic6 Parker Hannifin Corporation
Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Catalog 0802-2/USA
AccessoriesSolenoid Valves for VacuumVA01 Series
Blanking PlateSize Type Part Number
PSV23 Manifold V23BPPSP23
Individual Wired Connectors
Size Voltage Length Part Number
PSV23DC
.5 meter PC2D23CL5*
PSP23 1 meter PC2D23CL10
DC Voltage: Positive “+” (Red Wire)Negative “–” (Black Wire)
* PC2D23CL5 Connector included with valve.
SubbaseModel Number All Ports
V33SBM5 M5
Mounting screws and gaskets included with valve.
Part Number Type
V23SG Subbase & Manifold
Base Gasket Kits (Included with Valve)pneu
air
e
Pneumatic7 Parker Hannifin Corporation
Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
D
1 3
.22(5.5).49
(12.5)
.39 (10)
.39 (10)
.21(5.4)
.21(5.4)
M5 x 0.8Exhaust Port
M5 x 0.8Vacuum / Pressure Port
.19(4.7)
.57 (14.5)
1.43 (36.3)
.50(12.6)
.24(6)
1.94 (49.4)
2
.21(5.4)
.18(4.6)
M5 x 0.8Outlet Port
.59(15)
.79(20)
.10(2.5)
.10 Dia.(2.5) 2- Holes
PSV231PE &PSP231PE(Shown with Subbase)
1
.21(5.4)
.16 (4)
.16 (4)B
A
2
M5 x 0.8Output Port
M5 x 0.8Vacuum / Pressure Port
.138 Dia. Ø 3.5
.49(12.5)
.50(12.6)
1.63(41.3)
.24(6)
1.59(40.4)
.35(9)
2.05 (52.1)
.93(23.5)
.77(19.5)
.39(10)
.41(10.5)
.46(11.8)
3
.22(5.5)
M5 x 0.8Exhaust Port
.51(13)
Mtg. Holes
Manifold Assembly
n A B n A B
115.14 4.80(130) (122)
21.40 1.08
125.53 5.22
(35.5) (27.5) (140.5) (132.5)
31.81 1.50
135.94 5.63
(46) (38) (151) (143)
42.22 1.91
146.36 6.04
(56.5) (48.5) (161.5) (153.5)
52.64 2.32
156.77 6.46
(67) (59) (172) (164)
63.05 2.74
167.19 6.87
(77.5) (69.5) (182.5) (174.5)
73.46 3.15
177.60 7.28
(88) (80) (193) (185)
83.88 3.56
188.01 7.70
(98.5) (90.5) (203.5) (195.5)
94.29 3.98
198.43 8.11
(109) (101) (214) (206)
104.70 4.39
208.84 8.52
(119.5) (111.5) (224.5) (216.5)
n = Number of StationsInches (mm)
3
2 2 2 2
1No. 1 No. 2 n. . . .
2
31
1: Positive Pressure Port2: Output Port3: Exhaust Port
PSP23
2
31
1: Vacuum Supply Port2: Output Port3: Atmospheric Release Port
PSV23
Catalog 0802-2/USA
DimensionsSolenoid Valves for VacuumVA01 Series
pneu
air
e
Pneumatic8 Parker Hannifin Corporation
Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Solenoid Valves for VacuumVA01 Series
RDP33 Features• Lightweight, Compact, Direct Acting,
10mm Wide Solenoid Valve
• 3-Way, 3-Position Blocked Center Valvefor Use with Centralized VacuumSystems
• One Valve for Both Vacuum Control andBlow-off Control
• 5 ms Response Time
• Built-in Throttle Valve for RegulatingBlow-off Adjustment
• Vacuum Leakage is Reduced to LessThan .6 inHg / min (At 26.5 inHg,1.22 cu. in.)
• Inline Mount or Manifolds up to 20Stations are Available
Catalog 0802-2/USA
Features & Specifications
ApplicationsThe PEP33 3-Way, 3-Position Poppet valve, is used forvacuum applications with centralized vacuum systemand blow-off functions in one valve body. This valveeliminates the need for 2 separate 3-Way valves.
A built in Blow-off Throttle Valve allows the blow-offflow to be regulated at the valve for each application.The same 10mm wide valve can mounted as an inlinevalve close the application or on a manifold forcentralized control. The working port is blocked in thecenter condition keeping vacuum leakage to aminimum.
2
3 1
1: Positive Pressure Supply Port2: Output Port3: Vacuum Supply Port
RDP33
2
3 1
2 2 2
PFG Cup PFG Cup PFG Cup PFG Cup
Centralized VacuumSystemp
neu
air
e
Pneumatic9 Parker Hannifin Corporation
Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
D
Solenoid Valves for VacuumVA01 Series
SpecificationsModel Number VA01RDP33
Media AirPort Size M5 Female
FlowVacuum 0.35 [email protected] inHg (Port 3 to 2)
Vacuum Break 0.29 [email protected] PSI (Port 1 to 2)Pressure Range 29.5 inHg to 72.5 PSIProof Pressure .3 mPa (43.5 PSI) .75 mPa (108.7 PSI)
Ambient Temperature 14 to 122°F (-10 to 50°C) Response Time
ON 5 ms or LessOff 5 (20) ms or Less
Rated Voltage 24VDCPermissable Voltage
± 10%FluctuationHeat Resistance Grade Grade B, J154003
Power L Type 0.5WConsumption U Type 0.55W
Wiring Lead Wire, Connector with Lead WireVibration Resistance 150 m/s2
Shock Resistance 50 m/s2
Mass 1.59 oz. (45 g.)
Note: When using the valve for vacuum break at less than 41°F (5°C)by supplying compressed air, use dry air passing through an airdryer to prevent dew condensation and freezing.Response time in bracket () shows with surge suppressor.
VA01 RDP 33 1 UE MF
Mounting Type
RDP* Inline Valve
*Valve includes gasket &screws for ManifoldMounting.
Operator Function33 Double Solenoid,
3-Way, IntegratedThrottle Valve
Valve Model Number IndexBold Items Are Standard
Wiring TypeUE* Plug-in Connector
(With Indicator Light& Surge Protector
L 500mm Lead Wire(Without IndicatorLight & Surge Protector
* Includes 500mm Connector
MFU 06 V01 R3 CC M5N
Number ofStations
02 2-Station04 4-Station06 6-Station08 8-Station10 10-Station
Manifold Model Number IndexBold Items Are Standard
NOTE: Valve manifolds available up to 20 stations and in even andodd numbers. Consult Factory for availabilty
Catalog 0802-2/USA
Ordering Information
Type ofMountable ValveR3 RDP33pneu
air
e
Pneumatic10 Parker Hannifin Corporation
Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Catalog 0802-2/USA
AccessoriesSolenoid Valves for VacuumVA01 Series
Blanking PlateSize Type Part Number
RDP33 Manifold V33BP
Individual Wired Connectors
Size Voltage Length Part Number
RDP33 DC .5 meter PC2D23CL5*
1 meter PC2D23CL10
DC Voltage: Positive “+” (Red Wire)Negative “–” (Black Wire)
* PC2D23CL5 Connector included with valve.
Base Gasket Kits (Included with Valve)
Part Number Type
V33SG Subbase & Manifoldpneu
air
e
Pneumatic11 Parker Hannifin Corporation
Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
D
Catalog 0802-2/USA
Dimensions
.33(8.5)
.69(17.5)
.41 (10.5)
.22(5.5)
BA1.61
(41)Max.
1.52(38.5)Min
1.92(48.8)
.59(15)
.30(7.5)
.41 (10.5)
Throttle Valve for Vacuum Break
Flow Control
Port 31/8 NPTVacuum
Supply Port
Port 2M5 x 0.8
Output Port
.30(7.5)
.73(18.5)
Port 11/8 NPT
Positive PressureSupply Port
2.91(74)
1.57 (40)
.59 (15)
.14 (3.5)
.24 (6)
.10 (2.5)
.98 (25)
1.34 (34)
.14 Dia. (Ø 3.5)
Mtg. Holes
BlankingPlate
13
RDP33
Manifold Assembly
n A B n A B
115.51 4.80(140) (123)
21.79 1.08
125.93 5.22
(45.5) (28.5) (150.5) (133.5)
32.20 1.50
136.34 5.63
(56) (39) (161) (144)
42.62 1.91
146.75 6.04
(66.5) (49.5) (171.5) (154.5)
53.03 2.32
157.17 6.46
(77) (60) (182) (165)
63.44 2.74
167.58 6.87
(87.5) (70.5) (192.5) (175.5)
73.86 3.15
177.99 7.28
(98) (81) (203) (186)
84.27 3.56
188.41 7.70
(108.5) (91.5) (213.5) (196.5)
94.69 3.98
198.82 8.11
(119) (102) (224) (207)
105.10 4.39
209.23 8.52
(129.5) (112.5) (234.5) (217.5)
n = Number of StationsInches (mm)
2
3 1
1: Positive Pressure Supply Port2: Output Port3: Vacuum Supply Port
RDP33
2
3
1
2 2 2
.12(3) .12
(3)
.22(5.5)
.76(19.4)
.29(7.4)
.39(10)
.99(25.2) .37
(9.5)
.10(2.5)
.24(6)
1.09(27.8)
2.91(74)
1.46(37)
.06(1.5)
Manual Override(Vacuum Side)
Manual Override(Positive Pressure Side)
Port 2M5x0.8
Output Port
.07 Dia. (Ø 1.8) Mtg. Holes
.09 Dia. (Ø 2.2)
Mtg. Holes
Throttle Valve for VacuumBreak Flow Control
Solenoid Valves for VacuumVA01 Series
pneu
air
e
Pneumatic12 Parker Hannifin Corporation
Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Solenoid Valves for VacuumVA01 Series
PEP34 Features• Lightweight, Compact, Direct Acting,
10mm Wide Solenoid Valve
• 3-Way, 3-Position Exhaust Center Valvefor Use with Centralized VacuumSystems
• One Valve for Both Vacuum Control andBlow-off Control
• 5 ms Response Time
• Built-in Throttle Valve for RegulatingBlow-off Adjustment
• Manifolds up to 12 Stations are Available
• 130 Micron Filter in AtmosphericRelief Port
Catalog 0802-2/USA
Features & Specifications
ApplicationsThe PEP34 3-Way, 3-Position Poppet valve, is used forvacuum applications with centralized vacuum systemand blow-off functions in one valve body. This valveeliminates the need for 2 separate 3-Way valves.
A built in Blow-off throttle valve allows the blow-off flowto be regulated at the valve for each application. Thesame 10mm wide valve can mounted as an inline valveclose the application or on a manifold for centralizedcontrol.
The working port is open to atmosphere in the centercondition. In the transition from Vacuum to Blow-off,this atmospheric port helps reduce the time to breakthe seal of the part and reduces the possibility of partsaround the blow-off from being moved. More consistentblow off times can be realized and when detaching thepart, re-attraction after the vacuum seal is broken iseliminated.
AtmosphericPressure
Vacuum
Blowing Off byOvershoot ofBreaking Pressure
Time
Pre
ssur
e
Sol
enoi
d V
alve
for V
acuu
m B
reak
: OF
F
Sol
enoi
d V
alve
for V
acuu
m B
reak
: ON
Breaking TimeVaries
AtmosphericPressure
Vacuum
VacuumPumpPressureVaries
VacuumPumpPressureVaries
AtmosphericRelease
Time
Pre
ssur
e
Sol
enoi
d B
Sid
e: O
N
Sol
enoi
d A
Sid
e: O
FF
Sol
enoi
d B
Sid
e: O
FF
Reduces Variationof Breaking Time byAtmospheric Release
(Int
erm
edia
te P
ositi
on)
Reduces Overshoot
Example Without AtmosphericReleasing Mechanism
Example With AtmosphericReleasing Mechanism
2
Y
3 1
1: Positive Pressure Supply Port2: Output Port3: Vacuum Supply PortY: Atmospheric Release Port
PEP34
pneu
air
e
Pneumatic13 Parker Hannifin Corporation
Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
D
SpecificationsModel Number VA01PEP34
Media AirPort Size M5 Female
FlowVacuum 0.71 [email protected] inHg (Port 3 to 2)
Vacuum Break 0.50 [email protected] PSI (Port 1 to 2)Pressure Range 29.5 inHg to 72.5 PSIProof Pressure .75 mPa (108.7 PSI)
Ambient Temperature 14 to 122°F (-10 to 50°C) Response Time
ON 5 ms or LessOff 5 ms or Less
Rated Voltage 24VDCPermissable Voltage
± 10%FluctuationHeat Resistance Grade Grade B, J154003
Power Holding 0.9WConsumption Inrush 4W
Wiring Lead Wire, Connector with Lead WireVibration Resistance 150 m/s2
Shock Resistance 50 m/s2
Mass 1.98 oz. (56 g.)
Note: When using the valve for vacuum break at less than 41°F (5°C)by supplying compressed air, use dry air passing through an airdryer to prevent dew condensation and freezing.
Catalog 0802-2/USA
Ordering InformationSolenoid Valves for VacuumVA01 Series
VA01 PEP 34 1 UE F
Mounting TypePEP Subbase Valve Only
Operator Function34 Double Solenoid,
3-Position,Integrated ThrottleValve
Valve Model Number IndexBold Items Are Standard
Wiring TypeUE* Plug-in Connector
(With Indicator Light& Surge Protector
L 500mm Lead Wire(Without IndicatorLight & Surge Protector
* Includes 500mm Connector
MFS 6 V01 P4 CC M5
Manifold Model Number IndexBold Items Are Standard
NOTE: Valve manifolds available up to 12 stations and in evenand odd numbers. Consult Factory for availabilty
Number ofStations
02 2-Station04 4-Station06 6-Station08 8-Station
Type ofMountable ValveP4 PEP34
Note: Valve includes Exhaust Filter.
pneu
air
e
Pneumatic14 Parker Hannifin Corporation
Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Solenoid Valves for VacuumVA01 Series
Catalog 0802-2/USA
Accessories
Blanking PlateSize Type Part Number
PEP34 Manifold V34BP
Individual Wired Connectors
Size Voltage Length Part Number
PEP34 DC .5 meter PC2D23CL5*
1 meter PC2D23CL10
DC Voltage: Positive “+” (Red Wire)Negative “–” (Black Wire)
* PC2D23CL5 Connector included with valve.
SubbaseModel Number All Ports
V34SBM5 M5
Mounting screws and gaskets included with valve.
Base Gasket Kits (Included with Valve)
Replacement Filter
Part Number Type
V34SG Subbase & Manifold
Part Number Type
V34F 130m Filter, Package of 10
pneu
air
e
Pneumatic15 Parker Hannifin Corporation
Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
D
.22 (5.5)
.14(3.5)
.14(3.5)
BA1.61
(41)Max.
1.52(38.5)Min
1.91(48.5)
.59(15)
.31(8)
.63 (16) .22
(5.5).22
(5.5)
Throttle Valve for Vacuum Break
Flow Control
.57(14.5)
.06(1.5)
.41 (10.5)
Port 1 & 32 - M5 x 0.8
Port 2M5 x 0.8
Output Port
.31(8)
.63(16)2.91
(74)
1.46(37)
1.46(37)
.42(10.7)
.37(9.5)
.14(3.5)
.11(2.8)
.98(25)
.30 (7.5)
.57(14.5)
.41 (10.5)
Port 3M5 x 0.8
Vacuum Supply Port
.14 Dia. (Ø 3.5)
Mtg. Holes
BlankingPlate
Filter
2
13
Catalog 0802-2/USA
DimensionsSolenoid Valves for VacuumVA01 Series
n A B n A B
73.62 3.35(92) (85)
21.56 1.28
84.04 3.76
(39.5) (32.5) (102.5) (95.5)
31.97 1.69
94.45 4.17
(50) (43) (113) (106)
42.38 2.11
104.86 4.59
(60.5) (53.5) (123.5) (116.5)
52.80 2.52
115.28 5.00
(71) (64) (134) (127)
63.21 2.93
125.69 5.41
(81.5) (74.5) (144.5) (137.5)
n = Number of StationsInches (mm)
2
Y
3 1
1: Positive Pressure Supply Port2: Output Port3: Vacuum Supply PortY: Atmospheric Release Port
PEP34
3
1
2222
PEP34Subbase
Manifold Assembly
.39(10)
1.52(36.2)
1.52(38.5)
.43(11)
.28(7)
.24(7)
.47 (12)
Throttle Valve for Vacuum Break
Flow Control
Port 2M5 x 0.8
Output Port
2.91(74)
1.46(37)
1.46(37)
.94(24)
.16(4)
.63(16)
.26(6.5)
.71 (18) .59
(15)
.14 (3.5)
.11 (2.8)
.14 Dia. (Ø 3.5)
Mtg. Holes
Filter
Manual Override(Vacuum Side)
Manual Override(Positive Pressure Side)
2
.28(7)
.47(12)
.24(6)
Port 1M5 x 0.8
Positive PressureSupply Port
Port 3M5 x 0.8Vacuum
Supply Port
31
pneu
air
e
Pneumatic16 Parker Hannifin Corporation
Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Catalog 0802-2/USA
Metered Flow Sensing Valve
OperationWhen the flow of air from the cup side to the generatorside is greater than the switching flow rate of the valve,the float is drawn back against the spring and seals onthe housing. In this state, flow passes through anorifice on the float. Vacuum flow is “Checked”. (SeeFigure 1).
When the cup comes in contact and seals on aproduct, flow is reduced and the spring forces the floattowards the cup side inlet. This breaks the seal at thefloat and the full open state is restored. (See Figure 2).
Vacuum Flow Sensing ValveFSV Series – M5, G1, G2, G3
ApplicationMaintaining an acceptable level of vacuum is critical tothe performance of vacuum systems that have a singlesource vacuum generator with multiple cups. TheParker Flow Sensing Valve assists in maintaining anacceptable vacuum level if the vacuum cup does notmake a proper seal. The valve will automatically closeif the cup looses the seal with the product during a pickand place motion.
The Parker Flow Sensing Valve is a normally openvalve that switches to a closed metered state when thevacuum flow rate from the cup side to the generatorside is greater than the switching flow rate of the flowsensing valve. The Flow Sensing Valve “Checks” thevacuum flow. The vacuum flow rate of the generatormust be more than the switching flow rate of the FlowSensing Valve or it will not switch to a “Checked”position.
When using multiple Flow Sensing Valves pergenerator, the flow rate of the generator must be morethan the combined switching flow rates of the flowvalves and any other leak path. For Example, a CV20-HSN has a maximum flow rate of 3.88 SCFM and a 1/8Flow Sensing Valve has a switching flow rate of 0.28SCFM. Therefore 13 Flow Sensing Valves can beconnected in parallel to a CV20-HSN.
Once a Flow Sensing Valve is “Checked”, a smallamount of by-pass flow occurs. This leakage allows agenerator to be turned on prior to the cup being inplace on a product and is the flow path used toevacuate the cup volume. The by-pass flow willdecrease the maximum degree of vacuum in a systemand is considered a leak path when the cup is notsealed on a product. Blow off functions will still operateby forcing the Flow Sensing Valve to a full openposition, allowing the part to be blown off.
Features• Pick and Place Randomly Placed
Products
• Minimize Vacuum Loss when Cup Sealis Lost
• Direct Mounting to Cups
• M5 to G3/8 Connection
• Integrated Bronze Filter
Normally ClosedAir Supply
Suction Cup
Housing
Filter
Float
Meter Orifice
Spring
Figure 1(Closed, Metered Flow)
Figure 2(Open, Full Flow)
pneu
air
e
Pneumatic17 Parker Hannifin Corporation
Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
D
DimensionsB B1 D D1 L
FSV-M5 .18 .22 .08 M5 .57 .31(4.5) (5.5) (2) (14.5) (8)
FSV-G1 .26 .43 .16 G 1.42 .51(6.5) (11) (4) (36) (13)
FSV-G2 .33 .43 .16 G1/4 1.50 .67(8.5) (11) (4) (38) (17)
FSV-G3 .47 .51 .16 G3/8 1.65 .87(12) (13) (4 ) (42) (22)
Catalog 0802-2/USA
Ordering & Technical InformationVacuum Flow Sensing ValveFSV Series – M5, G1, G2, G3
SpecificationsPart Number FSV-M5 FSV-G1 FSV-G2 FSV-G3
Switching Flow Rate 0.18 SCFM 0.28 SCFM 0.875 SCFM
Nominal Size 2mm 4mm
Housing Material Galvanized Steel Anodised Aluminum
Filter Material Sintered Bronze Al-Niro Mesh
Temperature Range 14° F to 140° F (-10° C to 60° C)
Maximum Pressure 145 PSI 115 PSI
Media Atmospheric Air
Weight (grams) 0.005 0.009 0.016 0.029
Ordering InformationPart Number Description
FSV-M5 M5
FSV-G1 1/8” BSPP
FSV-G2 1/4” BSPP
FSV-G3 3/8” BSPP
B1B
D
L
VacuumGenerator
Side
CupSide
D1 D1
pneu
air
e
Pneumatic18 Parker Hannifin Corporation
Pneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Check ValveCH01 Series
Catalog 0802-2/USA
One Way Check Valve
SpecificationsOperating Temperature Range:32°F to 140°F (0° to 60°C)
Operating Vacuum Range:-4.25 to -13.89 PSIG (-8.7 to -.28.3 inHg)
Port Size:Pad Side = 1/4”, Generator Side = 1/8”
Leakage Rate:0.2 PSI / Minute (0.4 inHg / Minute)
Cracking Pressure:2.9 PSIG (5.9 inHg)
MaterialsValve Body / Fittings ......................... Brass / Aluminum
Seals .................................................................. BUNA
Spring .................................................................... SUS
Ordering InformationPart Number Description
CH-01G1 BSPP Ports
CH-01N1 NPT Ports.51 (13)
.75 (19)
.63 (16)
.75 (19)
1.81 (46)
1/4 NPT Pad Side
1/8 NPT Pad Side
Dia.
Dimensions
CharacteristicsThe CH Check valve is used to hold a degree ofvacuum downstream from the check valve when thevacuum generator upstream from the check valve isturned off. A separate blow-off connection downstreamfrom the CH check valve is required to detroy thevacuum pressure and blow off the part.
This check valve is an open or passing flow path whenthere is a differential pressure from the pad side to thegenerator side.
Features• Poppet Design
• Low Leakage
• Low Cracking Pressure
CH-01G1
PFG CupOptional MPS-6
CV
Normally Closed Air Supplywith Blow-off & Optional Sensor
pneu
air
e