validation of geant4 em physics for gamma rays against the sandia, epdl97 and nist databases

27
Validation of Geant4 EM physic s for gamma rays against the S ANDIA, EPDL97 and NIST databas es Zhang Qiwei INFN-LNS/CIAE 14th Geant4 Users and Collaboration Workshop Catania,Italy October 15,2009

Upload: gudrun

Post on 12-Jan-2016

42 views

Category:

Documents


0 download

DESCRIPTION

Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases. Zhang Qiwei INFN-LNS/CIAE. 14th Geant4 Users and Collaboration Workshop Catania,Italy October 15,2009. Outline. Verification before of validation Identification of data libraries for validation - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases

Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL

97 and NIST databases

Zhang QiweiINFN-LNS/CIAE

14th Geant4 Users and Collaboration WorkshopCatania,Italy October 15,2009

Page 2: Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases

2

Outline

Verification before of validation

Identification of data libraries for validation

SANDIA EPDL97 NIST

Validation of the Geant4 photon processes with respect to the data libraries

a) Verification for migrated processes (migrated vs non migrated) for Livermore & Penelope

b) Verification for migrated processes: comparison with Standard physics processes

Page 3: Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases

3

Migration of low energy EM processes

From version 9.2 of Geant4, the low energy EM processes and models (Livermore & Penelope) have been migrated to standard EM software design

A physical process can be simulated according to several models

models can be alternative and/or complementary on certain energy ranges

G4PhotoElectricEffect (standard default)

G4LivermorePhotoElectricModel

G4PenelopePhotoElectricModel

G4PhotoElectricEffect

Page 4: Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases

4

Photon processes:

Material: elements (15)

compounds : Air Water NaI

Photoelectric effect

Compton scattering

Gamma conversion

(pair production +triplet production)

Rayleigh scattering

Page 5: Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases

5

Verification for migrated processes (a)

Comparison of Mean Free Path (MFP) for the migrated processes: G4EmCaculator object

• G4LivermoreXxxModel.cc• G4PenelopeXxxModel.cc

vs

for non migrated processes: Changed the Geant4 code

• G4LowEnergyXxx.cc• G4PenelopeXxx.cc

Page 6: Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases

6

Comparison of MFP for Livermore model (Pb)

Comparison of MFP for Livermore model (Water)

photoelectric compton

gamma conversion rayleigh

Page 7: Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases

7

Comparison of MFP for Penelope model (Water)

Comparison of MFP for Penelope model (Ne)

photoelectric compton

gamma conversion rayleigh

Page 8: Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases

8

Verification for migrated processes (b)

Comparison of Mean Free Path (MFP) for the migrated processes: G4EmCaculator object

• G4LivermoreXxxModel.cc• G4PenelopeXxxModel.cc

vs

for Standard processes: G4EmCaculator object

• G4Xxx.cc

Page 9: Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases

9

Comparison with Standard physics processes (Ne)

Comparison with Standard physics processes (Pb)

photoelectric compton

gamma conversion rayleigh

Page 10: Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases

10

Identification of data libraries for validation SANIA National Laboratories provide analytical approximations to c

ross sections for both photoelectric absorption of photons by atoms and incoherent scattering of photons by atoms

Analytical Approximations for X-Ray Cross Section III

EPDL97 (Evaluated Photon Interaction Data Library) designed to meet the needs of users at Lawrence Livermore National Laboratory for use in photon transport calculations

http://www-nds.iaea.org/epdl97/ 

The National Institute of Standards and Technology (NIST) maintains a large number of databases about photon-atom interactions ( Form Factors, Attenuation & Scattering Tables, NIST X-Ray and Gamma-Ray Attenuation Coefficients and Cross Section)

http://physics.nist.gov/PhysRefData/contents.html 

Standard processes

Livermore processes

Page 11: Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases

11

Comparison of experimental libraries (H)

Comparison of experimental libraries (Ca)

photoelectric compton

gamma conversion rayleigh

Page 12: Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases

12

Comparison of experimental libraries (Air)

Comparison of experimental libraries (NaI)

photoelectric compton

gamma conversion rayleigh

Page 13: Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases

13

Validation of the Geant4 photon processes with respect to the libraries based on experimental data

SANDIA EPDL97 NIST

Retrieve the cross section : G4EmCalculator object

G4EmCalculator emCalemCal.ComputeCrossSectionPerAtom (energy,gamma,emName,Z,A,cut)OremCal.ComputeCrossSectionPerVolume (energy,gamma,emName,material,cut)

librariesdeviation = 1 -

model

Page 14: Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases

14

Comparison of XS per Atom between SANDIA and Geant4 (O photoelectric)

Page 15: Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases

15

Comparison of XS per Atom between SANDIA and Geant4 (Ba compton)

Page 16: Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases

16

Comparison of XS per Atom between EPDL97 and Geant4 (Al photoelectric)

Page 17: Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases

17

Comparison of XS per Atom between EPDL97 and Geant4 (Fe compton)

Page 18: Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases

18

Comparison of XS per Atom between EPDL97 and Geant4 (Se gamma conversion)

Page 19: Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases

19

Comparison of XS per Atom between EPDL97 and Geant4 (H rayleigh)

Page 20: Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases

20

Comparison of XS per Atom between NIST and Geant4 (Nb photoelectric)

Page 21: Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases

21

Comparison of XS per Atom between NIST and Geant4 (Ag compton)

Page 22: Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases

22

Comparison of XS per Atom between NIST and Geant4 (I gamma conversion)

Page 23: Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases

23

Comparison of XS per Atom between NIST and Geant4 (Cu rayleigh)

Page 24: Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases

24

The result in detail:

https://twiki.cern.ch/twiki/bin/view/Geant4/LoweValidation

In Penelope Rayleigh Model,G4EmCalculator object just can retrieve the XS per Atom (energy > 1GeV)

Retrieve the XS directly with the model’s methods

G4PenelopeRayleighModel* ray =

new G4PenelopeRayleighModel();

xs = ray->CrossSectionPerVolume

(material,gamma,energy,cut);

Page 25: Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases

25

G4EmCalculator object Direct methods

Comparison of XS per Atom

between NIST and Penelope Model (rayleigh)

Cu

Ag

Page 26: Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases

26

conclusions The Standard model cross sections originate from SANDIA,

their differences are small; In the similar case,the Livermore model cross sections are i

n good agreement with EPDL97; The cross sections of most photon models agree with NIST

within 10% except Penelope rayleigh model; The results of two methods (G4EmCalculator object and dir

ect methods) are agreement except Penelope rayleigh model;

It looks like Penelop rayleigh calculations by the G4EmCalculator are performed only above 1 GeV, namely outside the Penelope range. It is probably a limit/problem of the G4EmCalculator

Page 27: Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases

27

Thank you !