validation of guidelines for evaluating the moisture...
TRANSCRIPT
![Page 1: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/1.jpg)
Validation of Guidelines for Evaluating the Moisture Susceptibility of Warm Mix Asphalt Technologies September 28, 2016
![Page 2: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/2.jpg)
Today’s Presenters
• Moderator: Ed Harrigan, TRB
• Amy Epps Martin, Texas A&M University
• Edith Arambula, Texas A&M Transportation Institute
![Page 3: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/3.jpg)
NCHRP is...
A state-driven national program
• The state DOTs, through AASHTO’s Standing Committee on Research... – Are core sponsors of NCHRP
– Suggest research topics and select final projects
– Help select investigators and guide their work through oversight panels
![Page 4: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/4.jpg)
NCHRP delivers...
Practical, ready-to-use results • Applied research aimed at state
DOT practitioners • Often become AASHTO
standards, specifications, guides, manuals
• Can be directly applied across the spectrum of highway concerns: planning, design, construction, operation, maintenance, safety
![Page 5: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/5.jpg)
A range of approaches and products • Traditional NCHRP reports • Syntheses of highway practice • IDEA Program • Domestic Scan Program • Quick-Response Research for
AASHTO • Other products to foster
implementation: – Research Results Digests – Legal Research Digests – Web-Only Documents and CD-ROMs
![Page 6: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/6.jpg)
NCHRP Webinar Series • Part of TRB’s larger webinar
program • Opportunity to interact with
investigators and apply research findings.
![Page 7: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/7.jpg)
Today’s First Presenter
• Amy Epps Martin, Texas A&M University
![Page 8: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/8.jpg)
NCHRP 9-49B VALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM MIX
ASPHALT TECHNOLOGIES
Amy Epps Martin Edith Arámbula Mercado
Fan Yin
Webinar – September 2016
![Page 9: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/9.jpg)
INTRODUCTION • WMA with foaming or
additives provide economic, environmental, & engineering benefits
• Concerns remain regarding moisture susceptibility
2
(http://www.ksasphalt.com/Warmix.html)
![Page 10: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/10.jpg)
NCHRP 9-49 Performance of WMA Technologies: Stage I – Moisture Susceptibility
• Information gathering • 3 standard laboratory tests & field performance • LMLC, PMLC, & Cores from 9 mixtures in 4 field
projects • Appropriate aging protocols • Guideline Thresholds to identify and limit WMA
moisture susceptibility • NCHRP Report 763
3
![Page 11: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/11.jpg)
Current Use of WMA 54% Trial Projects 40% Routine Use Others Quantity of WMA 44% 2-5 Projects 21% 5-10 Projects 23% Routine
Preferred Technologies DBG, Evotherm, Sasobit, Advera, Terex, and AQUABlack
Use of Anti-stripping Additives 48% Yes
Organizational Practice 73% Allow 12% Not Allow Others
Moisture Susceptibility Testing in Mix Design 76% Yes
Preferred Moisture Susceptibility Tests 61% TSR 17% HWTT Others
Observed Field Pavement Failure or
Distress
91% None (Moisture Damage)
6% Compaction Issues
3% Thermal Cracking
NCHRP 9-49 Web Survey
![Page 12: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/12.jpg)
NCHRP 9-49 Laboratory Tests • Indirect Tensile (IDT) Strength
– Lottman Conditioning – Dry/Wet IDT Strength @25°C – Tensile Strength Ratio (TSR)
• Resilient Modulus (MR)
– Lottman Conditioning – Dry/Wet MR Stiffness @25°C – MR-ratio
5
![Page 13: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/13.jpg)
NCHRP 9-49 Laboratory Tests
• Hamburg Wheel Tracking Test – Stripping Inflection Point (SIP) – Stripping Slope
6
![Page 14: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/14.jpg)
OK
*
*
* *
NCHRP 9-49 Field Projects
7
![Page 15: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/15.jpg)
OK
*
*
* *
IOWA Location: U.S. 34 near Corning Construction: Completed September 2011 WMA Tech: Sasobit®, Evotherm® 3G Aggregates: Quartzite, Sandstone, River Sand 17% RAP Binder: PG 58-28 Anti-Strip: None
IA
NCHRP 9-49 Field Projects
8
![Page 16: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/16.jpg)
* OK
*
*
*
Texas Location: FM 973 Austin Construction: Completed January 2012 WMA Tech: Astec Green,
Evotherm DATTM
Aggregates: Limestone, Field Sand Binder: PG 70-22 Anti-Strip: None
NCHRP 9-49 Field Projects
9
![Page 17: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/17.jpg)
OK
*
* IA
Montana Location: IH 15 near Dillon Construction: Completed October 2011 WMA Tech: Aesco-Madsen Eco-Foam II,
Sasobit®, Evotherm® 3G
Aggregates: Siliceous Binder: PG 70-28 Anti-Strip: 1.4 % Lime
NCHRP 9-49 Field Projects
10
![Page 18: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/18.jpg)
OK
*
*
*
IA
New Mexico Location: IH 25 near
Truth or Consequences Construction: Completed October
2012 WMA Tech: Astec Green,
Evotherm® 3G Aggregates: Gravels, Sand 35% RAP Binder: PG 64-28 Anti-Strip: 1 % Versabind
*
NCHRP 9-49 Field Projects
11
![Page 19: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/19.jpg)
12
Sasobit (EB) Evotherm (EB)
Iowa Field Project 17 months in-service
NCHRP 9-49 Field Performance
![Page 20: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/20.jpg)
NCHRP 9-49 Performance Summary
13
Field Project
Const Date Climate Materials Traffic Field Lab
IA Sept 2011 Wet, F/T PG58-28
17% RAP Moderate,
US Hwy
Raveling
= WMAs vulnerable early, some ok w/age; HMAs marginal; lab tests separate
TX Jan 2012 Hot, Wet PG70-22
Heavy Trucks,
FM Road
“=“ WMAs vulnerable early, ok w/age
MT Oct 2011
Cold, Multi-F/T
PG70-28 1.4% Lime
Heavy, Interstate
= except wet IDT/TSR, on-site
NM Oct 2012
Dry, Cold Winter,
Hot Summer
PG64-28 35% RAP
1% Versabind
Heavy, Interstate
= except wet IDT/TSR, LMLC; MR-ratio, LMLC & Foaming on-site
![Page 21: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/21.jpg)
NCHRP 9-49 Thresholds (LMLC)
14
Test Parameter Iowa Texas Montana New Mexico
Evotherm Sasobit Evotherm Foaming Evotherm Sasobit Foaming Evotherm Foaming
Wet IDT (psi) 50 47 88 77 76 74 77 81 72
TSR (%) 84 77 79 66 59 57 72 73 70
Wet MR (ksi) 133 164 281 239 261 321 234 296
MR-ratio (%) 72 77 80 62 83 86 80 69 76
SIP (cycle) 1677 2176 6256 4111
>20000
>20000 >20000 >20000 >20000
Stripping Slope
(mm/cycle) 10 6.6 1.7 2.9 0 0 0 0 0
IA Use of Anti-stripping Agents - Mixtures are likely still moisture susceptible at early life - WMA Sasobit + Lime improved MR and MR-ratio
TX Use of Anti-stripping Agents - Improved with Lime TX LTOA - Improved after aging
NM LTOA - Improved after aging
Development Verification
![Page 22: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/22.jpg)
WMA Mix Design with LMLC
STOA 2 hrs. @ 240°F
HWTT AASHTO
T324
SIP & Stripping
Slope
Moisture AASHTO
T283
Wet IDT & TSR
IDT AASHTO
T 283
MR ASTM D7369
Wet MR & MR-ratio
OK
OK
No
No
No
OK
LTOA AASHTO R
30
STOA 2 hrs. @ 240°F
HWTT AASHTO
T324
Moisture AASHTO
T283
SIP & Stripping
Slope
IDT AASHTO
T 283
MR ASTM D7369
Wet IDT
Wet MR
≥115psi
≥450ksi
≥12,000 & ≤1.4µm/cycle
Moisture Susceptible
OK with Summer Aging
OK with Summer Aging
OK with Summer Aging
Moisture Susceptible
Moisture Susceptible
Moisture Susceptible
at Early Life
Add/modify anti-
stripping agent and/or
other mixture
components
Re-evaluate mixture
with LTOA
≥65psi &
≥70%
≥200ksi &
≥70%
≥3,500 & ≤5.3µm/cycle
select single test method and use throughout
9-49
![Page 23: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/23.jpg)
NCHRP 9-49B Performance of WMA Technologies: Stage I – Moisture Susceptibility Validation
• Review of Recent Relevant Literature • Follow-Up Web Survey • Collaboration with NCHRP 9-47A and 9-49A • Validation of 9-49 Thresholds • Laboratory Experiment to assess alternate moisture
conditioning protocols and explore various specimen-drying methods
• NCHRP Report 817
16
![Page 24: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/24.jpg)
17
Validate flow chart
• WMA pavements with moisture susceptibility data – Mix design
– Quality assurance
• Moisture susceptibility criteria
• WMA technology and materials
• Field performance
NCHRP 9-49B Web Survey
![Page 25: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/25.jpg)
18
41 of 50 states (82% response rate)
NCHRP 9-49B Web Survey
![Page 26: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/26.jpg)
WMA pavements routinely used in most states
19
NCHRP 9-49B Web Survey
![Page 27: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/27.jpg)
Most common WMA technologies: Evotherm, Foaming
20
NCHRP 9-49B Web Survey
![Page 28: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/28.jpg)
Anti-stripping agents required by the majority of states
21
NCHRP 9-49B Web Survey
![Page 29: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/29.jpg)
Moisture susceptibility testing required by most states
22
NCHRP 9-49B Web Survey
![Page 30: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/30.jpg)
Most common test method used is AASHTO T 283
Most common test parameter is Tensile Strength Ratio (TSR)
23
NCHRP 9-49B Web Survey
![Page 31: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/31.jpg)
Adequate WMA pavement performance
Typical WMA pavement age 5-6 years
24
NCHRP 9-49B Web Survey
![Page 32: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/32.jpg)
• 64 WMA mixtures from 44 field projects identified from web-survey respondents and NCHRP projects 9-47A and 9-49A
• Moisture susceptibility data – Mix design – QC/QA – Pavement performance
25
HWTT SIP
TSR & Wet IDT Strength
NCHRP 9-49B Threshold Validation
![Page 33: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/33.jpg)
HWTT SIP
26
0
3000
6000
9000
12000
15000
HW
TT S
IP
SIP=3,500PG 52-34 Michigan
89% Performance Correlation
NCHRP 9-49B Threshold Validation
![Page 34: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/34.jpg)
TSR & Wet IDT Strength (on-site PMLC specimen)
27
83% Performance Correlation
40%
60%
80%
100%
120%
0 50 100 150 200
TSR
Wet IDT Strength (psi)
NCAT
WSU
GDOT
COLAS
CDOT
TSR=70%
IDT Strength=65psi
PG 52-34 Michigan
NCHRP 9-49B Threshold Validation
![Page 35: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/35.jpg)
40%
60%
80%
100%
120%
0 50 100 150 200
TSR
Wet IDT Strength (psi)
NCAT
MODOT
GDOT
IADOT
AKDOT
TSR=70%
IDT Strength =100psi
TSR & Wet IDT Strength (off-site PMLC specimen)
28
87% Performance Correlation
Raveling in wheel paths
NCHRP 9-49B Threshold Validation
![Page 36: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/36.jpg)
29
TSR Threshold LAB : FIELD 65% 70% 75% 80%
True Positive FAIL : FAIL 2 2 2 2
False Negative PASS : FAIL 0 0 0 0
False Positive FAIL : PASS 8 8 10 15
True Negative PASS : PASS 43 43 41 36
TPR
---
1.00 1.00 1.00 1.00
FPR 0.16 0.16 0.20 0.29
Accuracy 0.85 0.85 0.81 0.72
NCHRP 9-49B ROC ANALYSIS - TSR
![Page 37: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/37.jpg)
30
0.0
0.2
0.4
0.6
0.8
1.0
0.0 0.2 0.4 0.6 0.8 1.0
TPR
FPR
ROC Space
TSR=65% TSR=70% TSR=75% TSR=80%
Perfect Classification
Better
Worse
NCHRP 9-49B ROC ANALYSIS - TSR
![Page 38: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/38.jpg)
31
Wet IDT Strength
Threshold LAB : FIELD 70
psi 80 psi
90 psi
100 psi
True Positive FAIL : FAIL 1 2 2 2
False Negative PASS : FAIL 1 0 0 0
False Positive FAIL : PASS 0 1 2 3
True Negative PASS : PASS 21 20 19 18
TPR
---
0.50 1.00 1.00 1.00
FPR 0.00 0.05 0.10 0.14
Accuracy 0.96 0.96 0.91 0.87
NCHRP 9-49B ROC ANALYSIS – IDT Strength
![Page 39: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/39.jpg)
32
0.0
0.2
0.4
0.6
0.8
1.0
0.0 0.2 0.4 0.6 0.8 1.0
TPR
FPR
ROC SpaceIDT Strength=70 IDT Strength=80 IDT Strength=90 IDT Strength=100
Perfect Classification
Better
Worse
NCHRP 9-49B ROC ANALYSIS – IDT Strength
![Page 40: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/40.jpg)
NCHRP 9-49B LABORATORY EXPERIMENT
33
Moisture Conditioning
Protocols
Dry Control
Modified Lottman
Moisture Induced Stress Tester
Hot Water Bath
Saturated-Surface Dry (SSD)
MR Test
IDT Strength Test
APA Test
Specimen-Drying
Methods
Modified Lottman
SSD
Air Dry
CoreDry
Oven Dry
MR Test
IDT Strength Test
Dry
![Page 41: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/41.jpg)
Moisture Conditioning Protocols • Modified Lottman (AASHTO T283)
– Vacuum saturation + 1 freeze/thaw cycle – 3 Days
• Moisture Induced Stress Tester (MIST)
– Temperature: 60°C – Pressure: 40 psi – 1,000 and 2,000 cycles – 0.5 Day
• Hot Water Bath (HWB)
– Temperature: 60°C – 3 Days
34
NCHRP 9-49B LABORATORY EXPERIMENT
![Page 42: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/42.jpg)
Wet MR Stiffness at 25°C
35
0
100
200
300
400
500
Dry Control AASHTOT283
MIST1000 cycles
MIST2000 cycles
Hot Water3 days
Res
ilien
t Mod
ulus
(ksi
)
Moisture Conditioning
77.4% 55.2% 76.3%84.6%
Reduced stiffness for all moisture conditioning protocols T 283 = 1,000 MIST = 3-day HWB > 2,000 MIST
MR-Ratio
NCHRP 9-49B LABORATORY EXPERIMENT
![Page 43: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/43.jpg)
Wet IDT Strength at 25°C
36
Reduced strength for all moisture conditioning protocols T 283 = 1,000 MIST = 3-day HWB > 2,000 MIST
0
30
60
90
120
Dry Control AASHTOT283
MIST1000 cycles
MIST2000 cycles
Hot Water3 days
IDT
Stre
ngth
(psi
)
Moisture Conditioning
84.3% 73.4% 90.6%88.8% TSR
NCHRP 9-49B LABORATORY EXPERIMENT
![Page 44: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/44.jpg)
0
4
8
12
16
20
Dry Control AASHTOT283
MIST1000 cycles
MIST2000 cycles
Hot Water3 days
APA
RR
P@10
,000
(µε/
cycl
e)
Moisture Conditioning
22.5% 31.6% 56.7%39.0%
APA Rutting Resistance at 50°C
37
Reduced rutting resistance for all moisture conditioning protocols 3-day HWB ≥ 1,000 MIST = 2,000 MIST > T 283
RRP Ratio
NCHRP 9-49B LABORATORY EXPERIMENT
![Page 45: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/45.jpg)
Statistical Analysis Results
38
Moisture Conditioning
Protocols MR Stiffness IDT Strength APA RRP
Dry Control A A A
Modified Lottman B B D
1,000-cycle MIST B B B-C
2,000-cycle MIST C C C-D
3-day HWB B B B
1,000 MIST and 3-day HWB proposed as two alternatives to the AASHTO T283 protocol for use in the moisture susceptibility guideline
NCHRP 9-49B LABORATORY EXPERIMENT
![Page 46: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/46.jpg)
Specimen-Drying Methods
• Saturated-surface dry (SSD) per AASHTO T 166
• 48-hour air dry at 25°C
• 24-hour oven dry at 40°C
• CoreDry per AASHTO PP 75
39
NCHRP 9-49B LABORATORY EXPERIMENT
![Page 47: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/47.jpg)
0
100
200
300
400
500
SaturatedSurface Dry
Air Dry(48 hours)
CoreDry Oven Dry(24 hours)
MR
Stiff
ness
(ksi
)
Test Condition
77.4% 66.0% 73.7% 68.4%
MR Stiffness at 25°C
40
SSD = CoreDry = Air Dry = Oven Dry
MR-Ratio
NCHRP 9-49B LABORATORY EXPERIMENT
![Page 48: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/48.jpg)
IDT Strength at 25°C
41
CoreDry > SSD = Air Dry > Oven Dry
0
30
60
90
120
SaturatedSurface Dry
Air Dry(48 hours)
CoreDry Oven Dry(24 hours)
IDT
Stre
ngth
(psi
)
Test Condition
84.3% 91.8% 77.3%82.1% TSR
NCHRP 9-49B LABORATORY EXPERIMENT
![Page 49: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/49.jpg)
SSD method – “Entrapped” water biased stiffness and strength
measurements due to pore pressure and incompressibility
Air dry & oven dry methods – Long time requirement
CoreDry method – Short time requirement
Specimen-Drying Methods
42
NCHRP 9-49B LABORATORY EXPERIMENT
![Page 50: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/50.jpg)
NCHRP 9-49B CONTRIBUTIONS Commentary on Guideline Thresholds for Revising
Appendix to AASHTO R 35
Revised Guideline Thresholds with flexibility in Laboratory Tests & Moisture Conditioning Protocols
43
![Page 51: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/51.jpg)
HWTT per AASHTO T 324
IDT Strength per AASHTO T 283
MR per modified ASTM D7369
≥ 65 psi & ≥ 70%
≥ 200 ksi & ≥ 70%
OK
OK
No
No
No
OK
LMLC Loose Mix
STOA 2 h @ 240°F (116°C)
≥ 115 psi
≥450 ksi
≥ 12,000 cycles &
≤ 1.4 µm/cycle
Moisture Susceptible
OK with Summer Aging
OK with Summer Aging
OK with Summer Aging
Moisture Susceptible
Moisture Susceptible
Moisture Susceptibility at Early Life
Add/modify anti-stripping agent and/or other mixture components
Re-evaluate mixture
with LTOA
≥ 3,500 cycles &
≤ 5.3 µm/cycle
a
b
b
Moisture Conditioning
Protocols
Laboratory Tests
Moisture Susceptibility Parameters
Thresholds (STOA Specimens)
Wet IDT Strength &
TSR
Wet MR & MR-ratio
SIP & Stripping
Slope
AASHTO T283
1,000-cycle MIST at 60°C
and 40 psi
3-day HWB at 60°C
LMLC, Loose Mix
STOA 2 h @ 240°F (116°C)
Wet IDT Strength
Wet MR
SIP & Stripping
Slope
HWTT per AASHTO T 324
IDT Strength per AASHTO T 283
MR per modified ASTM D7369
AASHTO T283
1,000-cycle MIST at 60°C
and 40 psi
3-day HWB at 60°C
Compacted Specimen LTOA per
AASHTO R 30
Moisture Conditioning
Protocols
Laboratory Tests
Moisture Susceptibility Parameters
Thresholds (LTOA Specimens)
9-49B
![Page 52: Validation of Guidelines for Evaluating the Moisture ...onlinepubs.trb.org/onlinepubs/webinars/160928.pdfVALIDATION OF GUIDELINES FOR EVALUATING THE MOISTURE SUSCEPTIBILITY OF WARM](https://reader030.vdocument.in/reader030/viewer/2022040901/5e7274a770908a23eb6524c5/html5/thumbnails/52.jpg)
Thank You!
Questions?
45