Van Hoosen Hall Photo Log For more information contact MSU Environmental Health and Safety – (517) 353-8956 1 Photo 1 – Asbestos-containing spray-on acoustical ceiling plaster (popcorn)

Upload: others

Post on 08-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Van Hoosen Hall Photo Log - Michigan State University · For more information contact MSU Environmental Health and Safety – (517) 353-8956 8 Photo 8 – Non asbestos-containing

Van Hoosen Hall Photo Log

For more information contact MSU Environmental Health and Safety – (517) 353-8956 1

Photo 1 – Asbestos-containing spray-on acoustical ceiling plaster (popcorn)

Page 2: Van Hoosen Hall Photo Log - Michigan State University · For more information contact MSU Environmental Health and Safety – (517) 353-8956 8 Photo 8 – Non asbestos-containing

Van Hoosen Hall Photo Log

For more information contact MSU Environmental Health and Safety – (517) 353-8956 2

Photo 2 – Non asbestos-containing plaster (smooth)

Page 3: Van Hoosen Hall Photo Log - Michigan State University · For more information contact MSU Environmental Health and Safety – (517) 353-8956 8 Photo 8 – Non asbestos-containing

Van Hoosen Hall Photo Log

For more information contact MSU Environmental Health and Safety – (517) 353-8956 3

Photo 3 – Non asbestos-containing 4” black cove molding and associated mastic

Page 4: Van Hoosen Hall Photo Log - Michigan State University · For more information contact MSU Environmental Health and Safety – (517) 353-8956 8 Photo 8 – Non asbestos-containing

Van Hoosen Hall Photo Log

For more information contact MSU Environmental Health and Safety – (517) 353-8956 4

Photo 4 – Non asbestos-containing 12” x 12” cream floor tile with white and tan streaks and associated mastic

Page 5: Van Hoosen Hall Photo Log - Michigan State University · For more information contact MSU Environmental Health and Safety – (517) 353-8956 8 Photo 8 – Non asbestos-containing

Van Hoosen Hall Photo Log

For more information contact MSU Environmental Health and Safety – (517) 353-8956 5

Photo 5 – Non asbestos-containing white sink undercoating

Page 6: Van Hoosen Hall Photo Log - Michigan State University · For more information contact MSU Environmental Health and Safety – (517) 353-8956 8 Photo 8 – Non asbestos-containing

Van Hoosen Hall Photo Log

For more information contact MSU Environmental Health and Safety – (517) 353-8956 6

Photo 6 – Asbestos-containing cream linoleum with mosaic pattern and associated mastic

Page 7: Van Hoosen Hall Photo Log - Michigan State University · For more information contact MSU Environmental Health and Safety – (517) 353-8956 8 Photo 8 – Non asbestos-containing

Van Hoosen Hall Photo Log

For more information contact MSU Environmental Health and Safety – (517) 353-8956 7

Photo 7 – Non asbestos-containing domestic water supply and return pipe joint and hanger insulation

and Asbestos-containing domestic water supply and

return pipe straight insulation

Page 8: Van Hoosen Hall Photo Log - Michigan State University · For more information contact MSU Environmental Health and Safety – (517) 353-8956 8 Photo 8 – Non asbestos-containing

Van Hoosen Hall Photo Log

For more information contact MSU Environmental Health and Safety – (517) 353-8956 8

Photo 8 – Non asbestos-containing 12” x 12” tan linoleum with swirl pattern and associated mastic

and Non asbestos-containing 4” cream cove molding and associated mastic

Page 9: Van Hoosen Hall Photo Log - Michigan State University · For more information contact MSU Environmental Health and Safety – (517) 353-8956 8 Photo 8 – Non asbestos-containing

Van Hoosen Hall Photo Log

For more information contact MSU Environmental Health and Safety – (517) 353-8956 9

Photo 9 – Non asbestos-containing 4” brown cove molding and associated mastic

Page 10: Van Hoosen Hall Photo Log - Michigan State University · For more information contact MSU Environmental Health and Safety – (517) 353-8956 8 Photo 8 – Non asbestos-containing

Van Hoosen Hall Photo Log

For more information contact MSU Environmental Health and Safety – (517) 353-8956

10

Photo 10 – Non asbestos-containing vinyl wood grain flooring and associated mastic

Page 11: Van Hoosen Hall Photo Log - Michigan State University · For more information contact MSU Environmental Health and Safety – (517) 353-8956 8 Photo 8 – Non asbestos-containing

Van Hoosen Hall Photo Log

For more information contact MSU Environmental Health and Safety – (517) 353-8956

11

Photo 11 – Asbestos-containing 9” x 9” beige floor tile with cream and tan streaks and associated mastic

Page 12: Van Hoosen Hall Photo Log - Michigan State University · For more information contact MSU Environmental Health and Safety – (517) 353-8956 8 Photo 8 – Non asbestos-containing

Van Hoosen Hall Photo Log

For more information contact MSU Environmental Health and Safety – (517) 353-8956

12

Photo 12 – Assumed asbestos-containing window and door frame caulk compound

Page 13: Van Hoosen Hall Photo Log - Michigan State University · For more information contact MSU Environmental Health and Safety – (517) 353-8956 8 Photo 8 – Non asbestos-containing

Van Hoosen Hall Photo Log

For more information contact MSU Environmental Health and Safety – (517) 353-8956

13

Photo 13 – Exterior of VanHoosen Hall

Page 14: Van Hoosen Hall Photo Log - Michigan State University · For more information contact MSU Environmental Health and Safety – (517) 353-8956 8 Photo 8 – Non asbestos-containing

Van Hoosen Hall Photo Log

For more information contact MSU Environmental Health and Safety – (517) 353-8956

14

Photo 14 – Asbestos-containing 9” x 9” dark brown floor tile with cream and rust streaks and associated mastic

Page 15: Van Hoosen Hall Photo Log - Michigan State University · For more information contact MSU Environmental Health and Safety – (517) 353-8956 8 Photo 8 – Non asbestos-containing

Van Hoosen Hall Photo Log

For more information contact MSU Environmental Health and Safety – (517) 353-8956

15

Photo 15 – Asbestos-containing steam/condensate supply and return pipe straight, pipe joint and hanger insulation