vapor control systems for ultrasound gu s systems

5
VAPOR CONTROL SYSTEMS FOR ULTRASOUND GUS ® SYSTEMS LET YOU WORK SAFELY WITH OPA & GLUTARALDEHYDE. GUS ® VAPOR CONTROL SYSTEMS: • Meet OSHA & JCAHO standards • Protect staff from toxic vapors • Protect your delicate probes • Require no costly ductwork • Prevent splashes and spills • Use 75% less disinfectant

Upload: others

Post on 25-Mar-2022

3 views

Category:

Documents


0 download

TRANSCRIPT

VAPOR CONTROL SYSTEMS FOR ULTRASOUND

GUS® SYSTEMS LET YOU WORK SAFELYWITH OPA & GLUTARALDEHYDE.

GUS®VAPOR CONTROL SYSTEMS:• Meet OSHA & JCAHO standards• Protect staff from toxic vapors• Protect your delicate probes• Require no costly ductwork• Prevent splashes and spills• Use 75% less disinfectant

WHAT’S WRONG WITH THESE METHODS?

* Source: HICPAC, FDA, CDC and AIUM guidelines

There’s nothing wrong withCidex OPA, just don’t put theprobe straight into the bottle.

PROBLEMS:• Can tip over• Uses entire gallon• Contamination by

touching neck of bottlewith probe

• No vapor control

Wipes are a widely useddisinfectant for externalultrasound probes.*

PROBLEM:Wipes are not an FDAapproved high-leveldisinfectant. Vaginal, rectaland TEE probes are requiredto be disinfected with anFDA approved high-leveldisinfectant.

No issue – as long asthe tray is inside a vaporcontrol system.

PROBLEMS:

• Uses entire gallon• Probe handle can be

submerged• No vapor control

T-Spray is a widely useddisinfectant for externalultrasound probes.*

PROBLEM:T-Spray is not an FDAapproved high-leveldisinfectant. Vaginal, rectaland TEE probes are requiredto be disinfected with anFDA approved high-leveldisinfectant.

PCI medical first introduced its innovative vapor control technologyin 1995. At that time, the common high-level disinfectant wasGlutaraldehyde, hence the name “GUS” (Glutaraldehyde User Station).Today, both OPA and Glutaraldehyde are used to disinfect instrumentsand both disinfectants require the same safety engineering controls.

With over 6,000 systems used in hospitals and clinics, GUS® VaporControl Systems have been proven effective in protecting staff fromtoxic vapors and preventing damage to instruments.

KEY FEATURES:1. Cushioned grip clips suspend delicate probes inside container

2. Electrical connector sits on cushioned pad

3. Large intake area captures vapors when probe is removed

4. Patented filter traps OPA and Glutaraldehyde vapors

5. Containers use less than one quart of disinfectant

6. Delicate tip does not touch bottom of container

7. Whisper quiet blowers return clean air to room

8. Locking safety door (not shown) allows for installationin patient area

COMMON MISTAKES IN PROBE DISINFECTION

THE GUS® SOLUTION

1

3

5

67

4

2

FEATURES:• Eliminates fumes and protects staff

• Meets OSHA and JCAHO requirements

• Protects delicate probes by suspendingthem with a grip clip in soak container

• Safety door allows placement in patient area

• Uses 75% less disinfectant

• Used in over 6,000 hospitals and offices

SPECIFICATIONS:Model G10VP G14KANumber of probes soaked 1 2Face Velocity FPM 50 50Electrical (115V 50/60Hz) .5A .5AWidth 10"* 10"*Depth 10" 10"Height 22.25" 22.25"Weight (lbs) 24 28

* Allow 2”extra on left side for access to power switch

UL and CE approved.230V models available.Options shown below have different space requirements.

OPTIONS:

GUS® VAPOR CONTROL SYSTEMS FOR VAGINAL AND RECTAL ULTRASOUND PROBES

Counter-top Stand

Longer Containers

Replacement Containers

Abdominal Probe Trays

Model G14KA:Three 12" containers,two for soak andone for rinse

Model G10VP:Two 12" containers,one for soak andone for rinse

FEATURES:The G14TC-3 comes with threetubes. Two tubes allow you to soaktwo TEE probes simultaneously in thehigh-level disinfectant. The third tubeis for the initial water rinse whichshould be done at the system toprotect you from off-gassing anddrips. The special curved tubes onthe TC model make it easy to insertand remove your long probes. Thesafety cage protects against damageto the tubes and probes.

SPECIFICATIONS:Model G14TC-3Number of probes soaked 2Face Velocity FPM 50Electrical (115V 50/60Hz) .5AWidth 15"*Depth 16"Height 51"Weight (lbs) 55

UL and CE approved.230V models available.

* Needs 2” on each side for proper ventilation

GUS® VAPOR CONTROL SYSTEMS & ACCESSORIES FOR ULTRASOUND TEE PROBES

TEE Probe Holder

The AC-TCRK is acomplete systemfor safely storingyour TEE probesafter disinfection.It is made up ofthree components:a 48"slotted,removable tubewhich protectsyour probe intransit, a curvedstrain relief toprotect the delicatecord, and a paddedelectrical connectorholder.

THE TD-100: THE ONLY AUTOMATEDDISINFECTOR FOR TEE PROBES

iTest PRO™ UltrasoundLeakage Tester

The iTest PRO™ is designedto electrically test most typesof ultrasound transducers.The iTest™ measures boththe conductivity of thecleaning medium and theleakage current of theultrasound transducer. Easyto use with a simple Pass/Failmode. Includes a universaladapter. Recommended forTEE probes.

AC-Test

The AC-Test allows youto use your Dale/Flukeelectrical tester with theG14TC-3 workstation.Includes the InterfaceAdapter, test holder, two48" leads with banana clips.

• Protects your probe and protects your staff

• Compact size: 24"w x 8"d x 44"h

• Fast turnaround –under 15 minutes!

• Printed verification

PCI Medical Inc. PO Box 188 12 Bridge St. Deep River, CT 06417

Tel: USA (800) 862-3394 International (860) 526-2862 Fax: (860) 526-3081 Email: [email protected]

SAFETY ACCESSORIES – PROTECT YOURSELF AND STAY COMPLIANT!

Probe Holder

Store your delicateultrasound probes safely!Comes with a paddedelectrical connector holder,curved strain relief (whichprevents damage to thedelicate cord), storagetube and cleaning brush.Both the clear plastic probeholder and the steelelectrical connector holdercan withstand significantimpacts.

Rinse Station

Standardize the rinseprocess after the high-leveldisinfection of yourendocavity probes. Mosthigh-level disinfectantsrequire a series of threevolume rinses using potableor sterile water. Rinse yourendocavity probe in a simple3-step procedure by fullyimmersing the probe ineach container for a minute.

Replacement Front

Bring your old GUS G14VPor G14VC up to date witha new front. Includes newlouvres, new 12" containersto soak probe up throughthe handle, a new safetylocking door so you canleave your GUS in a patientarea, and redesignedspring clips. Note that youwill need to wall-mountyour updated GUS system.

Cart

Powder-coated steel cartsare available in multiplesizes. The top shelf is spill-safe with a raised lip andthe handy bottom shelfcan store anything fromSpill Kits, Glute-Out® toyour high-level disinfectant.Easy to maneuver withlocking casters. Assembleon site.

Glute-Out® Neutralizer

Used Glutaraldehyde orOPA is toxic and disposal ofthese chemicals is highlyregulated by many statesand municipalities. Glute-Out® is a glycine-basedpowder neutralizer thateffectively deactivates bothGlutaraldehyde and OPA.Available in threeconvenient sizes.

Glute-Out® Caddy

The Caddy is a convenientstorage system for yourGlute-Out® neutralizer.Includes removablecountdown timer, wallbracket and 5 bottles ofNG-QT Glute-Out® (eachbottle deactivates one quartof disinfectant). The Caddykeeps your Glute-Out®

neutralizer close at hand.

Spill Kit

Spilled Glutaraldehyde orOPA is dangerous. OSHAand ANSI standards requirethat spills be cleaned upimmediately as they createa rapid increase of fumes.JCAHO requires that a spillcontainment response teambe created and recommendskeeping a spill kit close tothe point of use.

Filter Replacement Plan

Save 25% with the All-At-Once (AAO) FilterReplacement Plan. Receive4 filters all at once (2 years’worth). We’ll remind youto change your filter every6 months. The AAOPlan extends your GUSwarranty for an extra yearif purchased together.