vcp6-dcv official cert guide

108

Upload: others

Post on 11-Sep-2021

13 views

Category:

Documents


0 download

TRANSCRIPT

Page 2: VCP6-DCV Official Cert Guide

VCP6-DCVOfficial Cert Guide

(Exam #2VO-621)

Page 3: VCP6-DCV Official Cert Guide

VMware Press is the official publisher of VMware books and training materials, which

provide guidance on the critical topics facing today’s IT professionals and students.

VMware virtualization and cloud infrastructure technologies simplify IT complexity and

streamline operations, helping organizations of all kinds and sizes to become more ag-

ile, efficient, and profitable.

VMware Press provides proven, technically accurate information that will help you

achieve your goals for customizing, building, and maintaining a virtual environment—

from the data center to mobile devices to the public, private, and hybrid cloud.

With books, certification and study guides, video training, and learning tools produced

by world-class architects and IT experts, VMware Press helps you master a diverse

range of topics on virtualization and cloud computing and is the official source of refer-

ence materials for preparing for the VMware Certified Professional certifications.

VMware Press is also pleased to have localization partners that can publish its products

into more than 42 languages, including, but not limited to, Chinese (Simplified), Chinese

(Traditional), French, German, Greek, Hindi, Japanese, Korean, Polish, Russian, and

Spanish.

For more information about VMware Press, please visit vmwarepress.com.

Page 4: VCP6-DCV Official Cert Guide

This page intentionally left blank

Page 5: VCP6-DCV Official Cert Guide

VCP6-DCVOfficial Cert Guide

(Exam #2VO-621)

John A. DavisSteve Baca

Owen Thomas

Hoboken, NJ • Boston • Indianapolis • San FranciscoNew York • Toronto • Montreal • London • Munich • Paris • Madrid

Capetown • Sydney • Tokyo • Singapore • Mexico City

Page 6: VCP6-DCV Official Cert Guide

VCP6-DCV Offi cial Cert Guide (Exam #2VO-621)Copyright © 2016 VMware, Inc.

Published by Pearson Education, Inc.

Publishing as VMware Press

All rights reserved. Printed in the United States of America. This publication is protected by copyright, and permission must be obtained from the publisher prior to any prohibited reproduction, storage in a retrieval system, or transmission in any form or by any means, electronic, mechanical, photocopying, recording, or likewise. For information regarding permissions, request forms, and the appropri-ate contacts within the Pearson Education Global Rights & Permissions Depart-ment, please visit www.pearsoned.com/permissions/.

ISBN-10: 0-7897-5648-X

ISBN-13: 978-0-7897-5648-0

Library of Congress Control Number: 2016903596

First Printing: May 2016

All terms mentioned in this book that are known to be trademarks or service marks have been appropriately capitalized. The publisher cannot attest to the accuracy of this information. Use of a term in this book should not be regarded as affecting the validity of any trademark or service mark.

VMware terms are trademarks or registered trademarks of VMware in the United States, other countries, or both.

Warning and DisclaimerEvery effort has been made to make this book as complete and as accurate as pos-sible, but no warranty or fitness is implied. The information provided is on an “as is” basis. The authors, VMware Press, VMware, and the publisher shall have neither liability nor responsibility to any person or entity with respect to any loss or damages arising from the information contained in this book or from the use of the DVD or programs accompanying it.

The opinions expressed in this book belong to the author and are not necessarily those of VMware.

Special SalesFor information about buying this title in bulk quantities, or for special sales opportunities (which may include electronic versions; custom cover designs; and content particular to your business, training goals, marketing focus, or branding interests), please contact our corporate sales department at [email protected] or (800) 382-3419.

For government sales inquiries, please contact [email protected].

For questions about sales outside the U.S., please [email protected].

EDITOR-IN-CHIEF

Mark Taub

EXECUTIVE EDITOR

Mary Beth Ray

VMWARE PRESS PROGRAM MANAGER

Karl Childs

DEVELOPMENT EDITOR

Ellie Bru

MANAGING EDITOR

Sandra Schroeder

PROJECT EDITOR

Mandie Frank

COPY EDITOR

Kitty Wilson

PROOFREADER

Debbie Williams

INDEXER

Ken Johnson

EDITORIAL ASSISTANT

Vanessa Evans

COVER DESIGNER

Chuti Prasertsith

COMPOSITOR

Studio GaLou

Page 7: VCP6-DCV Official Cert Guide

We Want to Hear from You!

As the reader of this book, you are our most important critic and commentator. We value your opinion and want to know what we’re doing right, what we could do bet-ter, what areas you’d like to see us publish in, and any other words of wisdom you’re willing to pass our way.

We welcome your comments. You can email or write us directly to let us know what you did or didn’t like about this book—as well as what we can do to make our books better.

Please note that we cannot help you with technical problems related to the topic of this book.

When you write, please be sure to include this book’s title and author as well as your name, email address, and phone number. We will carefully review your com-ments and share them with the author and editors who worked on the book.

Email: [email protected]

Mail: VMware Press ATTN: Reader Feedback 800 East 96th Street Indianapolis, IN 46240 USA

Reader ServicesVisit our website at www.pearsonitcertification.com/title/9780789756480 and register this book for convenient access to any updates, downloads, or errata that might be available for this book.

Page 8: VCP6-DCV Official Cert Guide

Dedication

She came to us in such a whirl,

This precious little angel girl.

A fragile life, doctors would say,

Yet perfect to us in every way.

She changed us all from the very start.

Touching each and every heart.

God loves us all, I’ll always believe.

He sent his angel of proof to you and me.

Everything I see, Everything I do,

Madison Hope I think of you.

You now see us clearly, that I know,

For God has brought his angel home.

Dedicated to my oldest granddaughter,

Madison Hope Stith,

03/20/2000 to 01/17/2012

—With Love, Grampy (John Davis)

Page 9: VCP6-DCV Official Cert Guide

First and foremost, I would like to dedicate this book to my loving wife, Sharyl. Without

your support I would not be able to commit the time necessary to co-author a book. Thank

you for believing in me and allowing me to have the time for my many endeavors. I

would also like to dedicate this book to my children: Zachary, Brianna, Eileen, Susan,

Keenan, and Maura. Also a shout-out to my dog, Baxter, who helps me clear my head on

our 3:00 walks to the park and back.

—Steve Baca

I would like to dedicate this book to my wife, Angela, and our daughter, Emma Jean. You

have been very patient with the amount of time it has taken me to write, rewrite, re-

search, and make sure that I have been as thorough as possible in my contributions to this

book. Thank you for putting up with my nerding out and delving deeper into the world

of VMware through all these years.

—Owen Thomas

Page 10: VCP6-DCV Official Cert Guide

x VCP6-DCV Official Cert Guide (Exam #2VO-621)

About the Authors

John A. Davis, now a product architect at Rackspace, became a VMware Certified Instructor (VCI) and VMware Certified Professional (VCP) in 2004. Since then, all of his work has been completely focused on VMware-based technologies. He has experience in teaching official VMware curriculum in five countries and delivering VMware professional services throughout the United States. Recently, his work has involved designing solutions based on vRealize Operations and Site Recovery Manager. He has authored several white papers and co-authored the VCAP5-DCA

Cert Guide (VMware Press). He holds several advanced certifications, including VCAP5-DCA, VCAP5-DCD, VCAP5-DTD, VCAP5-CID, and VCIX-NV. He has been a vExpert since 2014. He is author of the vLoreBlog.com and can be found on Twitter @johnnyadavis.

Steve Baca, VCAP, VCI, VCP, and NCDA, has been in the computer industry for more than 20 years. Originally a computer programmer and a system administra-tor working on Unix and Windows systems, he migrated over to technical training and wrote a course for Sun Microsystems. After teaching various courses for Sun, he eventually transitioned to VMware about 8 years ago, doing technical training and consulting as well as teaching for NetApp. Currently he lives in Omaha, Nebraska, and does a number of worldwide engagements. He thoroughly enjoys teaching and writing and believes that the constant evolution of the computer industry requires continuously learning to stay ahead. Steve can be found on Twitter @scbaca1.

Owen Thomas, VCI Level 2, VCP-DCV, VCP-Cloud, VCP-DT, VCAP-DCA, has been teaching various VMware classes since 2008. His first major IT position was in an enterprise-level NOC in Louisville, Kentucky, where he started in 2000 as a backup operator and transitioned to the role of NOC analyst. As his experience increased, he was tasked with training new staff. Introduced to VMware as of ver-sion 2 and trained in VI3, he became a VMware Certified Instructor at the end of 2007. Since then, he has taught hundreds of VMware classes for open enrollment and onsite classes for customers. Owen is a VMware partner and solutions pro-vider as well as a technical trainer and performs JumpStarts, Audits, HealthChecks, Capacity Planning, and P2V migrations for SMBs.

Page 11: VCP6-DCV Official Cert Guide

About the Reviewers

Dave Davis has spent his career carrying out expert management and engineering innovations for corporate leaders in the virtualization space. Over the past 12 years, he has gained extensive experience and knowledge in the IT industry, backed by a abroad range of in-depth professional certifications like VCAP-DCD 5, VCAP-DCA 5, VCP5-DCV, VCP6-DCV, Cisco CCNA, and MCSA/E, with hopes of obtaining the VCDX in data center virtualization. Dave recently received VMware’s vExpert 2016 for his contributions at www.virtualizestuff.com, where he talks about various VMware topics and about his home lab configuration.

As a VMware subject matter expert, Jordan Roth currently designs and builds VMware’s VCA, VCP, and VCAP certification exam curriculum. Jordan’s passion for virtualization started in 2006, with the release of VMware GSX. Ever since then, he has been at the forefront of architecture design and implementation for small business, healthcare, financing, and classified/unclassified federal, state, and local government entities. Jordan is a VMware Certified Professional on vSphere versions 3, 4, 5, and 6 as well as a VMware Certified Sales Professional with specialization in server sprawl reduction.

Page 12: VCP6-DCV Official Cert Guide

Acknowledgments

I would like to thank my wife and best friend Delores, who supports my late-night writing and gives me reason to be happy every day.

I would like to thank my parents, Monica and Norman Davis, who ensured that I received a solid education and learned from their great work ethics. My siblings and I did not attend preschool or kindergarten; my Mom taught us to read.

Thank you to Charlie Hagerty, the president of New Age Technologies, for molding me into a strong instructor and consulting engineer.

I would like to thank my co-authors Steve Baca and Owen Thomas, who were great partners in this adventure. Thanks to our technical editors, Dave Davis and Jordan Roth, for their hard work and dedication. Special thanks to Mary Beth Ray (execu-tive editor) and Ellie Bru (development editor) for coordinating everything and keeping this project moving in spite of all of our obstacles.

Finally, I would like to thank my granddaughter and grandson, Emma and Jaxon Rosebush. They put a lot of joy in Delores’s and my lives. I know I will be able to stay focused to complete my day’s work on time whenever I plan to spend the after-noon or weekend with them. All work and no play makes Grampy a dull boy.

—John Davis

There are so many people to acknowledge and thank for making this book possible. First, thanks to my wife and family for supporting me while writing this book. I would also like to thank my fellow co-authors John Davis and Owen Thomas, who spent many hours working on this book, and contributing to our bi-weekly confer-ence call with Ellie and Mary Beth. Thank you to the production team and editors at VMware Press/Pearson Publishing, Ellie Bru and Mary Beth Ray, and the rest of the team at Pearson Publishing, who do a tremendous amount of work from the initial planning of the book to the final printing.

—Steve Baca

I want to thank my wife and daughter for letting me have the time to contribute to this book. I would also like to thank John Davis and Steve Baca for allowing me to tag along with them on this book. Despite the blueprint changing halfway through, I think it has been a positive experience. I’d like to thank John Davis for starting me down the path to not just VMware but instruction as well. Who knows where my life would have taken me had I not taken his class all of those years ago? Thank you to Mary Beth Ray and Ellie Bru for keeping us all on track. I want to finally thank VMware for being this amazing ever-growing thing that has captivated my imagination and managed to hold onto it in a way that no other technology has.

—Owen Thomas

Page 13: VCP6-DCV Official Cert Guide

Contents at a Glance

Introduction xxviii

Chapter 1 Security 3

Chapter 2 Networking, Part 1 61

Chapter 3 Networking, Part 2 135

Chapter 4 Storage, Part 1 159

Chapter 5 Storage, Part 2 189

Chapter 6 Storage, Part 3 225

Chapter 7 Upgrade a vSphere Deployment to 6.x 259

Chapter 8 Resource Pools 289

Chapter 9 Backup and Recovery 317

Chapter 10 Troubleshoot Common Issues 351

Chapter 11 Troubleshoot Storage, Networks, and Upgrades 395

Chapter 12 Troubleshoot Performance 447

Chapter 13 Troubleshoot Clusters 495

Chapter 14 Deploy and Consolidate 529

Chapter 15 Confi gure and Administer vSphere Availability Solutions 569

Chapter 16 Virtual Machines 593

Chapter 17 Final Preparation 631

Glossary 639

Appendix A Answers to the “Do I Know This Already?” Quizzes and Review Questions 647

Appendix B Memory Tables 655

Appendix C Memory Tables Answer Key 689

Index 722

Page 14: VCP6-DCV Official Cert Guide

Contents

Introduction xxviii

Chapter 1 Security 3

“Do I Know This Already?” Quiz 3

Foundation Topics 6

Objective 1.1—Confi gure and Administer Role-based Access Control 6

Compare and Contrast Propagated and Explicit Permission Assignments 6

View/Sort/Export User and Group Lists 6

Add/Modify/Remove Permissions for Users and Groups on vCenter Server Inventory

Objects 7

Determine How Permissions Are Applied and Inherited in vCenter Server 10

Create/Clone/Edit vCenter Server Roles 14

Confi gure VMware Directory Service 15

Apply a Role to a User/Group and to an Object or a Group of Objects 16

Change Permission Validation Settings 17

Determine the Appropriate Set of Privileges for Common Tasks in vCenter Server 18

Compare and Contrast Default System/Sample Roles 20

Determine the Correct Permissions Needed to Integrate vCenter Server with Other

VMware Products 21

Objective 1.2—Secure ESXi, vCenter Server, and vSphere Virtual Machines 23

Harden Virtual Machine Access 23

Control VMware Tools Installation 24

Control VM Data Access 27

Configure Virtual Machine Security Policies 28

Harden a Virtual Machine Against Denial-of-Service Attacks 29

Control VM–VM Communications 29

Control VM Device Connections 29

Configure Network Security Policies 29

Harden ESXi Hosts 30

Enable/Configure/Disable Services in the ESXi Firewall 31

Change Default Account Access 34

Add an ESXi Host to a Directory Service 35

Apply Permissions to ESXi Hosts Using Host Profiles 36

Enable Lockdown Mode 37

Control Access to Hosts (DCUI/Shell/SSH/MOB) 38

Harden vCenter Server 39

Control Datastore Browser Access 39

Create/Manage vCenter Server Security Certificates 39

Control MOB Access 40

Page 15: VCP6-DCV Official Cert Guide

Change Default Account Access 40

Restrict Administrative Privileges 40

Understand the Implications of Securing a vSphere Environment 40

Objective 1.3—Enable SSO and Active Directory Integration 41

Describe SSO Architecture and Components 41

Differentiate Available Authentication Methods with VMware vCenter 42

Perform a Multi-site SSO Installation 42

Confi gure/Manage Active Directory Authentication 45

Confi gure/Manage Platform Services Controller (PSC) 48

Confi gure/Manage VMware Certifi cate Authority (VMCA) 50

Enable/Disable Single Sign-On (SSO) Users 51

Upgrade a Single/Multi-site SSO Installation 53

Confi gure SSO Policies 54

Add/Edit/Remove SSO Identity Sources 55

Add an ESXi Host to an AD Domain 55

Summary 56

Exam Preparation Tasks 56

Review All the Key Topics 56

Complete the Tables and Lists from Memory 56

Defi nitions of Key Terms 56

Answer Review Questions 57

Chapter 2 Networking, Part 1 61

“Do I Know This Already?” Quiz 61

Foundation Topics 65

Objective 2.1—Confi gure Advanced Policies/Features and Verify Network Virtualization

Implementation 65

Compare and Contrast vSphere Distributed Switch (vDS) Capabilities 65

Create/Delete a vSphere Distributed Switch 68

Add/Remove ESXi Hosts from a vSphere Distributed Switch 72

Add/Confi gure/Remove dvPort Groups 82

Add/Remove Uplink Adapters to dvUplink Groups 86

Confi gure vSphere Distributed Switch General and dvPort Group Settings 90

Create/Confi gure/Remove Virtual Adapters 93

Migrate Virtual Machines to/from a vSphere Distributed Switch 98

Migrating Virtual Machines Individually 98

Migrating Multiple Virtual Machines 100

Confi gure LACP on dvUplink and dvPort Groups 101

Describe vDS Security Policies/Settings 109

Confi gure dvPort Group Blocking Policies 111

Confi gure Load Balancing and Failover Policies 113

Confi gure VLAN/PVLAN Settings for VMs Given Communication Requirements 114

Page 16: VCP6-DCV Official Cert Guide

xvi VCP6-DCV Official Cert Guide (Exam #2VO-621)

Confi gure Traffi c Shaping Policies 119

Enable TCP Segmentation Offl oad Support for a Virtual Machine 122

Enable Jumbo Frames Support on Appropriate Components 123

Determine Appropriate VLAN Confi guration for a vSphere Implementation 127

Recognize Behavior of vDS Auto-Rollback 127

Confi gure vDS Across Multiple vCenter Servers to Support Long-Distance vMotion 129

Summary 131

Exam Preparation Tasks 131

Review All the Key Topics 131

Complete the Tables and Lists from Memory 131

Defi nitions of Key Terms 132

Answer Review Questions 132

Chapter 3 Networking, Part 2 135

“Do I Know This Already?” Quiz 135

Foundation Topics 138

Objective 2.2—Confi gure Network I/O Control (NIOC) 138

Defi ne Network I/O Control 138

Explain Network I/O Control Capabilities 138

Confi gure NIOC Shares/Limits Based on VM Requirements 142

Explain the Behavior of a Given Network I/O Control Setting 146

Determine Network I/O Control Requirements 148

Differentiate Network I/O Control Capabilities 148

Enable/Disable Network I/O Control 148

Monitor Network I/O Control 151

Summary 153

Exam Preparation Tasks 154

Review All the Key Topics 154

Complete the Tables and Lists from Memory 154

Defi nitions of Key Terms 154

Answer Review Questions 155

Chapter 4 Storage, Part 1 159

“Do I Know This Already?” Quiz 159

Foundation Topics 163

Objective 3.1—Manage vSphere Storage Virtualization 163

Storage Protocols 163

Identify Storage Adapters and Devices 163

Display Storage Adapters for a Host 164

Storage Devices for an Adapter 164

Fibre Channel Protocol 166

Page 17: VCP6-DCV Official Cert Guide

Contents xvii

Fibre Channel over Ethernet Protocol 166

iSCSI Protocol 166

NFS Protocol 167

Authentication NFSv4.1 with Kerberos Authentication 167

Native Multipathing and Session Trunking 167

In-band, Mandatory, and Stateful Server-Side File Locking 167

Identify Storage Naming Conventions 168

Identify Hardware/Dependent Hardware/Software iSCSI Initiator Requirements 170

Discover New Storage LUNs 171

Confi gure FC/iSCSI/FCoE LUNs as ESXi Boot Devices 172

FC 172

iSCSI 172

FCoE 173

Create an NFS Share for Use with vSphere 173

Enable/Confi gure/Disable vCenter Server Storage Filters 173

iSCSI 175

Configure/Edit Hardware/Dependent Hardware Initiators 175

Enable/Disable Software iSCSI Initiator 176

Configure/Edit Software iSCSI Initiator Settings 177

Determine Use Case for Hardware/Dependent Hardware/Software iSCSI Initiator 177

Configure iSCSI Port Binding 178

Enable/Configure/Disable iSCSI CHAP 180

Determine Use Cases for Fibre Channel Zoning 183

Compare and Contrast Array and Virtual Disk Thin Provisioning 183

Array Thin Provisioning 183

Virtual Disk Thin Provisioning 184

Determine Use Case for and Configure Array Thin Provisioning 184

Summary 185

Exam Preparation Tasks 185

Review All the Key Topics 185

Complete the Tables and Lists from Memory 186

Defi nitions of Key Terms 186

Answer Review Questions 186

Chapter 5 Storage, Part 2 189

“Do I Know This Already?” Quiz 189

Foundation Topics 193

Objective 3.2—Confi gure Software-defi ned Storage 193

Explain VSAN and VVOL Architectural Components 193

VSAN 193

VVOL 194

Page 18: VCP6-DCV Official Cert Guide

xviii VCP6-DCV Official Cert Guide (Exam #2VO-621)

Determine the Role of Storage Providers in VSAN 195

Determine the Role of Storage Providers in VVOLs 196

Explain VSAN Failure Domains Functionality 197

Confi gure/Manage VMware Virtual SAN 197

Create/Modify VMware Virtual Volumes (VVOLs) 201

Confi gure Storage Policies 202

Enable/Disable Virtual SAN Fault Domains 203

Create Virtual Volumes Given the Workload and Availability Requirements 204

Collect VSAN Observer Output 204

Create Storage Policies Appropriate for Given Workloads and Availability

Requirements 206

Confi gure VVOLs Protocol Endpoints 206

Objective 3.3—Confi gure vSphere Storage Multipathing and Failover 207

Explain Common Multipathing Components 207

Differentiate APD and PDL States 207

Compare and Contrast Active Optimized vs. Active non-Optimized Port

Group States 208

Explain Features of Pluggable Storage Architecture (PSA) 209

MPP 209

NMP 210

SATP 210

PSP 210

Understand the Effects of a Given Claim Rule on Multipathing and Failover 210

Explain the Function of Claim Rule Elements 211

Change the Path Selection Policy Using the UI 213

Determine the Effect of Changing PSP on Multipathing and Failover 214

Determine the Effect of Changing SATP on Multipathing and Failover 215

Confi gure/Manage Storage Load Balancing 215

Differentiate Available Storage Load Balancing Options 216

Differentiate Available Storage Multipathing Policies 216

Confi gure Storage Policies 217

Locate Failover Events in the UI 218

Summary 218

Exam Preparation Tasks 219

Review All the Key Topics 219

Complete the Tables and Lists from Memory 220

Defi nitions of Key Terms 220

Answer Review Questions 221

Chapter 6 Storage, Part 3 225

“Do I Know This Already?” Quiz 225

Foundation Topics 229

Page 19: VCP6-DCV Official Cert Guide

Contents xix

Objective 3.4—Perform Advanced VMFS and NFS Confi gurations and Upgrades 229

Describe VAAI Primitives for Block Devices and NAS 229

Enable/Disable vStorage APIs for Array Integration (VAAI) 230

Differentiate VMware File System Technologies 231

Compare and Contrast VMFS and NFS Datastore Properties 232

Upgrade VMFS3 to VMFS5 232

Compare Functionality of New and Upgraded VMFS5 Datastores 233

Differentiate Physical Mode and Virtual Mode RDMs 233

Create a Virtual/Physical Mode RDM 234

Differentiate NFS 3.x and 4.1 Capabilities 235

Confi gure Bus Sharing 236

Confi gure Multi-writer Locking 237

Connect an NFS 4.1 Datastore Using Kerberos 238

Create/Rename/Delete/Unmount VMFS Datastores 239

Create a VMFS Datastore 239

Rename a VMFS Datastore 240

Delete a VMFS Datastore 240

Unmount a VMFS Datastore 240

Mount/Unmount an NFS Datastore 241

Mount an NFS Datastore 241

Unmount an NFS Datastore 242

Extend/Expand VMFS Datastores 242

Expandable 242

Extending 242

Place a VMFS Datastore in Maintenance Mode 243

Select the Preferred Path/Disable a Path to a VMFS Datastore 244

Given a Scenario, Determine a Proper Use Case for Multiple VMFS/NFS Datastores 245

Objective 3.5—Set Up and Confi gure Storage I/O Control 246

Describe the Benefi ts of SIOC 246

Enable and Confi gure SIOC 247

Confi gure/Manage SIOC 249

Monitor SIOC 250

Differentiate Between SIOC and Dynamic Queue Depth Throttling Features 252

Given a Scenario, Determine a Proper Use Case for SIOC 252

Compare and Contrast the Effects of I/O Contention in Environments With and Without

SIOC 253

Summary 253

Exam Preparation Tasks 254

Review All the Key Topics 254

Complete the Tables and Lists from Memory 255

Defi nitions of Key Terms 255

Answer Review Questions 255

Page 20: VCP6-DCV Official Cert Guide

xx VCP6-DCV Official Cert Guide (Exam #2VO-621)

Chapter 7 Upgrade a vSphere Deployment to 6.x 259

“Do I Know This Already?” Quiz 259

Foundation Topics 263

Objective 4.1—Perform ESXi Host and Virtual Machine Upgrades 263

Update Manager 263

Confi gure Download Source(s) 264

Set Up UMDS to Set Up Download Repository 265

Import ESXi Images 265

Create Baselines and/or Baseline Groups 267

Attach Baselines to vSphere Objects 267

Scan vSphere Objects 269

Stage Patches and Extensions 269

Remediate an Object 269

Upgrade a vSphere Distributed Switch 270

Upgrade VMware Tools 271

Upgrade Virtual Machine Hardware 272

Upgrade an ESXi Host Using vCenter Update Manager 273

Stage Multiple ESXi Host Upgrades 274

Objective 4.2—Perform vCenter Server Upgrades 276

Compare the Methods of Upgrading vCenter Server 276

Embedded Architecture Deployment 278

External Architecture Deployment 278

Back Up vCenter Server Database and Certifi cates 279

Embedded Windows vCenter Server 279

Embedded Linux vCenter Server Appliance Database 279

Certificates 280

Perform Update as Prescribed for Appliance or Installable 280

Pre-Upgrade Updates for Linux vCenter Appliance 280

Pre-Upgrade Updates for Windows Installer 281

Upgrade vCenter Server Appliance (vCSA) 281

Given a Scenario, Determine the Upgrade Compatibility of an Environment 283

Scenario Conclusion 284

Determine Correct Order of Steps to Upgrade a vSphere Implementation 284

Summary 285

Exam Preparation Tasks 285

Review All the Key Topics 285

Complete the Tables and Lists from Memory 286

Defi nitions of Key Terms 287

Answer Review Questions 287

Page 21: VCP6-DCV Official Cert Guide

Contents xxi

Chapter 8 Resource Pools 289

“Do I Know This Already?” Quiz 289

Foundation Topics 293

Objective 5.1—Confi gure Advanced/Multilevel Resource Pools 293

Understand/Apply 293

Determine the Effect of the Expandable Reservation Parameter on

Resource Allocation 295

Create a Resource Pool Hierarchical Structure 296

Confi gure Custom Resource Pool Attributes 301

Determine How Resource Pools Apply to vApps 301

Describe vFlash Architecture 301

Create/Remove a Resource Pool 306

Add/Remove Virtual Machines from a Resource Pool 308

Create/Delete vFlash Resource Pool 309

Assign vFlash Resources to VMDKs 309

Given a Scenario, Determine Appropriate Shares, Reservations, and Limits for

Hierarchical Resource Pools 311

Summary 312

Exam Preparation Tasks 312

Review All the Key Topics 312

Complete the Tables and Lists from Memory 313

Defi nitions of Key Terms 313

Answer Review Questions 313

Chapter 9 Backup and Recovery 317

“Do I Know This Already?” Quiz 317

Foundation Topics 321

Objective 6.1—Confi gure and Administer a vSphere Backups/Restore/Replication Solution 321

Compare and Contrast vSphere Replication Compression Methods 321

Differentiate VMware Data Protection Capabilities 322

Confi gure Recovery Point Objective (RPO) for a Protected Virtual Machine 323

Explain VMware Data Protection Sizing Guidelines 324

Create/Delete/Consolidate Virtual Machine Snapshots 325

Install and Confi gure VMware Data Protection 327

Create a Backup Job with VMware Data Protection 334

Backup/Restore a Virtual Machine with VMware Data Protection 335

Install/Confi gure/Upgrade vSphere Replication 340

Confi gure VMware Certifi cate Authority (VMCA) integration with vSphere

Replication 341

Confi gure vSphere Replication for Single/Multiple VMs 342

Recover a VM Using vSphere Replication 345

Page 22: VCP6-DCV Official Cert Guide

xxii VCP6-DCV Official Cert Guide (Exam #2VO-621)

Perform a Failback Operation Using vSphere Replication 346

Deploy a Pair of vSphere Replication Virtual Appliances 347

Summary 347

Exam Preparation Tasks 347

Review All the Key Topics 347

Complete the Tables and Lists from Memory 348

Defi nitions of Key Terms 348

Answer Review Questions 348

Chapter 10 Troubleshoot Common Issues 351

“Do I Know This Already?” Quiz 351

Foundation Topics 354

Objective 7.1—Troubleshoot vCenter Server, ESXi Hosts, and Virtual Machines 354

Monitor Status of the vCenter Server Service 354

Perform Basic Maintenance of a vCenter Server Database 357

Monitor Status of ESXi Management Agents 359

Determine ESXi Host Stability Issues and Gather Diagnostics Information 361

Monitor ESXi System Health 368

Locate and Analyze vCenter Server and ESXi Logs 369

Determine the Appropriate Command-Line Interface (CLI) Command for a Given

Troubleshooting Task 372

Troubleshoot Common Issues 376

vCenter Server Service 377

Single Sign-On (SSO) 378

vCenter Server Connectivity 380

Virtual Machine Resource Contention, Configuration, and Operation 383

Platform Services Controller (PSC) 386

Problems with Installation 387

VMware Tools Installation 388

Fault Tolerant Network Latency 389

Summary 391

Exam Preparation Tasks 391

Review All the Key Topics 391

Complete the Tables and Lists from Memory 391

Defi nitions of Key Terms 392

Answer Review Questions 392

Chapter 11 Troubleshoot Storage, Networks, and Upgrades 395

“Do I Know This Already?” Quiz 395

Foundation Topics 399

Objective 7.2—Troubleshoot vSphere Storage and Network Issues 399

Page 23: VCP6-DCV Official Cert Guide

Contents xxiii

Identify and Isolate Network and Storage Resource Contention and

Latency Issues 399

Monitor Networking and Storage Resources Using vROps Alerts and All Badges 399

Verify Network and Storage Confi guration 404

Verify a Given Virtual Machine Is Confi gured with the Correct Network Resources 410

Monitor/Troubleshoot Storage Distributed Resource Scheduler (SDRS) Issues 414

Recognize the Impact of Network and Storage I/O Control Confi gurations 418

Recognize a Connectivity Issue Caused by a VLAN/PVLAN 422

Troubleshoot Common Issues 423

Storage and Network 423

Virtual Switch and Port Group Configuration 426

Physical Network Adapter Configuration 427

VMFS Metadata Consistency 428

Objective 7.3—Troubleshoot vSphere Upgrades 430

Collect Upgrade Diagnostic Information 431

Recognize Common Upgrade Issues with vCenter Server and vCenter Server

Appliance 431

Create/Locate/Analyze VMware Log Bundles 432

Determine Alternative Methods to Upgrade ESXi Hosts in the Event of Failure 434

VMware Update Manager 434

Interactively Using the ESXi Installer 434

Scripted Upgrades 435

vSphere Auto Deploy 437

ESXi Command Line 438

Confi gure vCenter Server Logging Options 439

Summary 442

Preparation Tasks 442

Review All the Key Topics 442

Complete the Tables and Lists from Memory 442

Defi nitions of Key Terms 442

Answer Review Questions 443

Chapter 12 Troubleshoot Performance 447

“Do I Know This Already?” Quiz 447

Foundation Topics 450

Objective 7.4—Troubleshoot and Monitor vSphere Performance 450

Monitor CPU and Memory Usage (Including vRealize Badges and Alerts) 450

Identify and Isolate CPU and Memory Contention Issues 451

Recognize Impact of Using CPU/Memory Limits, Reservations, and Shares 452

Describe and Differentiate Critical Performance Metrics 454

Describe and Differentiate Common Metrics—Memory 455

Describe and Differentiate Common Metrics—CPU 463

Page 24: VCP6-DCV Official Cert Guide

xxiv VCP6-DCV Official Cert Guide (Exam #2VO-621)

Describe and Differentiate Common Metrics—Network 465

Describe and Differentiate Common Metrics—Storage 466

Monitor Performance Through ESXTOP 467

Troubleshoot Enhanced vMotion Compatibility (EVC) Issues 473

Troubleshoot Virtual Machine Performance via vRealize Operations 477

Compare and Contrast Overview and Advanced Charts 483

Describe How Tasks and Events Are Viewed in vCenter Server 484

Identify Host Power Management Policy 489

Summary 491

Exam Preparation Tasks 491

Review All the Key Topics 491

Complete the Tables and Lists from Memory 491

Defi nitions of Key Terms 492

Answer Review Questions 492

Chapter 13 Troubleshoot Clusters 495

“Do I Know This Already?” Quiz 495

Foundation Topics 497

Objective 7.5—Troubleshoot HA and DRS Confi guration and Fault Tolerance 497

Troubleshoot Issues with DRS Workload Balancing 497

Troubleshoot Issues with HA Failover/Redundancy, Capacity, and Network

Confi guration 500

Troubleshoot Issues with HA/DRS Cluster Confi guration 507

Troubleshoot Issues with vMotion/Storage vMotion Confi guration and/or Migration 511

Troubleshoot Issues with Fault Tolerance Confi guration and Failover Issues 514

Explain DRS Resource Distribution Graph and Target/Current Host Load Deviation 519

Explain vMotion Resource Maps 523

Summary 524

Exam Preparation Tasks 524

Review All the Key Topics 524

Complete the Tables and Lists from Memory 525

Defi nitions of Key Terms 525

Answer Review Questions 525

Chapter 14 Deploy and Consolidate 529

“Do I Know This Already?” Quiz 529

Foundation Topics 532

Objective 8.1—Deploy ESXi Hosts Using Auto Deploy 532

Describe the Components and Architecture of an Auto Deploy Environment 532

Use Auto Deploy Image Builder and PowerCLI Scripts 533

Implement Host Profi les with an Auto Deploy of an ESXi Host 537

Install and Confi gure Auto Deploy 539

Page 25: VCP6-DCV Official Cert Guide

Contents xxv

Understand PowerCLI cmdlets for Auto Deploy 540

Deploy Multiple ESXi Hosts Using Auto Deploy 541

Given a Scenario, Explain the Auto Deploy Deployment Model Needed to Meet a

Business Requirement 542

Objective 8.2—Customize Host Profi le Settings 542

Edit an Answer File to Customize ESXi Host Settings 542

Modify and Apply a Storage Path Selection Plug-in (PSP) to a Device Using Host

Profi les 543

Modify and Apply Switch Confi gurations Across Multiple Hosts Using a Host Profi le 544

Create/Edit/Remove a Host Profi le from an ESXi Host 546

Import/Export a Host Profi le 548

Attach and Apply a Host Profi le to ESXi Hosts in a Cluster 549

Perform Compliance Scanning and Remediation of an ESXi Host and Clusters Using Host

Profi les 552

Enable or Disable Host Profi le Components 555

Objective 8.3—Consolidate Physical Workloads Using VMware Converter 556

Install a vCenter Converter Standalone Instance 556

Convert Physical Workloads Using vCenter Converter 557

Modify Server Resources During Conversion 561

Interpret and Correct Errors During Conversion 562

Deploy a Physical Host as a Virtual Machine Using vCenter Converter 563

Collect Diagnostic Information During Conversion Operation 564

Resize Partitions During the Conversion Process 564

Given a Scenario, Determine Which Virtual Disk Format to Use 565

Summary 565

Exam Preparation Tasks 566

Review All the Key Topics 566

Complete the Tables and Lists from Memory 566

Defi nitions of Key Terms 566

Answer Review Questions 567

Chapter 15 Confi gure and Administer vSphere Availability Solutions 569

“Do I Know This Already?” Quiz 569

Foundation Topics 573

Objective 9.1—Confi gure Advanced vSphere HA Features 573

Modify vSphere HA Advanced Cluster Settings 573

Confi gure a Network for Use with HA Heartbeats 574

Apply an Admission Control Policy for HA 575

Enable/Disable Advanced vSphere HA Settings 576

Confi gure Different Heartbeat Datastores for an HA Cluster 578

Apply Virtual Machine Monitoring for a Cluster 579

Confi gure Virtual Machine Component Protection (VMCP) Settings 580

Page 26: VCP6-DCV Official Cert Guide

xxvi VCP6-DCV Official Cert Guide (Exam #2VO-621)

Implement vSphere HA on a Virtual SAN Cluster 581

Explain How vSphere HA Communicates with Distributed Resource Scheduler and

Distributed Power Management 581

Objective 9.2—Confi gure Advanced vSphere DRS Features 582

Confi gure VM-Host Affi nity/Anti-affi nity Rules 582

Confi gure VM-VM Affi nity/Anti-affi nity Rules 584

Add/Remove Host DRS Group 585

Add/Remove Virtual Machine DRS Group 585

Enable/Disable Distributed Resource Scheduler (DRS) Affi nity Rules 586

Confi gure the Proper Distributed Resource Scheduler (DRS) Automation Level Based on a

Set of Business Requirements 587

Explain How DRS Affi nity Rules Affect Virtual Machine Placement 588

Summary 589

Exam Preparation Tasks 589

Review All the Key Topics 589

Complete the Tables and Lists from Memory 589

Defi nitions of Key Terms 590

Answer Review Questions 590

Chapter 16 Virtual Machines 593

“Do I Know This Already?” Quiz 593

Foundation Topics 597

Objective 10.1—Confi gure Advanced vSphere Virtual Machine Settings 597

Determine How Using a Shared USB Device Impacts the Environment 597

Confi gure Virtual Machines for vGPUs, DirectPath I/O, and SR-IOV 598

Confi gure Virtual Machines for Multicore vCPUs 602

Differentiate Virtual Machine Confi guration Settings 603

Interpret Virtual Machine Confi guration File (.vmx) Settings 610

Enable/Disable Advanced Virtual Machine Settings 611

Objective 10.2—Create and Manage a Multi-site Content Library 612

Publish a Content Catalog 613

Subscribe to a Published Catalog 613

Determine Which Privileges Are Required to Globally Manage a Content Catalog 613

Compare the Functionality of Automatic Sync and On-Demand Sync 614

Confi gure Content Library to Work Across Sites 614

Confi gure Content Library Authentication 616

Set/Confi gure Content Library Roles 617

Add/Remove Content Libraries 618

Objective 10.3—Confi gure and Maintain a vCloud Air Connection 619

Create a VPN Connection Between vCloud Air and On-premise Site 619

Deploy a Virtual Machine Using vCloud Air 621

Page 27: VCP6-DCV Official Cert Guide

Contents xxvii

Migrate a Virtual Machine to vCloud Air 621

Verify VPN Connection Confi guration to vCloud Air 623

Confi gure vCenter Server Connection to vCloud Air 623

Confi gure Replicated Objects in vCloud Air Disaster Recovery Service 625

Given a Scenario, Determine the Required Settings for Virtual Machines Deployed in

vCloud Air 627

Summary 628

Preparation Tasks 628

Review All the Key Topics 628

Complete the Tables and Lists from Memory 628

Defi nitions of Key Terms 628

Answer Review Questions 629

Chapter 17 Final Preparation 631

Getting Ready 631

Taking the Exam 634

Glossary 639

Appendix A Answers to the “Do I Know This Already?” Quizzes and Review Questions 647

Appendix B Memory Tables 655

Appendix C Memory Tables Answer Key 689

Index 722

Page 28: VCP6-DCV Official Cert Guide

xxviii VCP6-DCV Official Cert Guide (Exam #2VO-621)

Introduction

This book focuses on one major goal: helping you prepare to pass the VCP6-DCV exam (2V0-621). You may find this book useful for other purposes, such as learning how to troubleshoot vSphere or as a tool to partially prepare for other exams, but primarily you should use this book to prepare for the 2V0-621 exam.

The rest of this introduction focuses on two topics: the 2V0-621 exam and a description of this book.

The VMware Certifi ed Professional 6—Data Center Virtualization (VCP6-DCV) Exam

The VCP6-DCV Exam is the second exam that is required to achieve VCP6-DCV certification. The exam became available August 30, 2015. The primary objective of the VCP6-DCV exam is to demonstrate that you have mastered the skills to success-fully install, deploy, scale, and manage the VMware vSphere 6 environments. The format of the exam is multiple-choice questions in a proctored environment.

Contents of the VCP6-DCV Exam

Every student who ever takes an exam wants to know what’s on the exam. For all of its exams, VMware publishes a set of exam topics that give general guidance about what’s on the exam.

You can find the exam topics at vmware.com. A good way to find the topics is to navigate to www.vmware.com/certification and look for the VCP6-DCV certification.

A big goal of this book is to make sure you are prepared for any topic you might encounter on the VCP6-DCV exam. Therefore, in addition to covering topics in the official recommended course list, this book covers topics not found in the list of courses.

Page 29: VCP6-DCV Official Cert Guide

Introduction xxix

Table I-1 lists the topics on the VCP6-DCV exam blueprint, with a reference to the chapter or chapters of this book that covers the topic.

Table I-1 VCP6-DCV Exam Topics and Chapter References

Exam Section/Objective

Chapter Where Covered

Section 1: Configure and Administer vSphere 6.x Security

Objective 1.1: Configure and Administer Role-based Access Control Chapter 1

Objective 1.2: Secure ESXi, vCenter Server, and vSphere Virtual Machines Chapter 1

Objective 1.3: Enable SSO and Active Directory Integration Chapter 1

Section 2: Configure and Administer Advanced vSphere 6.x Networking

Objective 2.1: Configure Advanced Policies/Features and Verify Network Virtualization Implementation

Chapter 2

Objective 2.2: Configure Network I/O Control (NIOC) Chapter 3

Section 3: Configure and Administer Advanced vSphere 6.x Storage

Objective 3.1: Manage vSphere Storage Virtualization Chapter 4

Objective 3.2: Configure Software-defined Storage Chapter 5

Objective 3.3: Configure vSphere Storage Multi-pathing and Failover Chapter 5

Objective 3.4: Perform Advanced VMFS and NFS Configurations and Upgrades

Chapter 6

Objective 3.5: Setup and Configure Storage I/O Control Chapter 6

Section 4: Upgrade a vSphere Deployment to 6.x

Objective 4.1: Perform ESXi Host and Virtual Machine Upgrades Chapter 7

Objective 4.2: Perform vCenter Server Upgrades Chapter 7

Section 5: Administer and Manage vSphere 6.x Resources

Objective 5.1: Configure Advanced/Multilevel Resource Pools Chapter 8

Section 6: Backup and Recover a vSphere Deployment

Objective 6.1: Configure and Administer a vSphere Backups/Restore/Replication Solution

Chapter 9

Section 7: Troubleshoot a vSphere Deployment

Objective 7.1: Troubleshoot vCenter Server, ESXi Hosts, and Virtual Machines

Chapter 10

Objective 7.2: Troubleshoot vSphere Storage and Network Issues Chapter 11

Objective 7.3: Troubleshoot vSphere Upgrades Chapter 11

Page 30: VCP6-DCV Official Cert Guide

xxx VCP6-DCV Official Cert Guide (Exam #2VO-621)

Exam Section/Objective

Chapter Where Covered

Objective 7.4: Troubleshoot and Monitor vSphere Performance Chapter 12

Objective 7.5: Troubleshoot HA and DRS Configurations and Fault Tolerance

Chapter 13

Section 8: Deploy and Consolidate vSphere Data Center

Objective 8.1: Deploy ESXi Hosts Using Autodeploy Chapter 14

Objective 8.2: Customize Host Profile Settings Chapter 14

Objective 8.3: Consolidate Physical Workloads using VMware Converter Chapter 14

Section 9: Configure and Administer vSphere Availability Solutions

Objective 9.1: Configure Advanced vSphere HA Features Chapter 15

Objective 9.2: Configure Advanced vSphere DRS Features Chapter 15

Section 10: Administer and Manage vSphere Virtual Machines

Objective 10.1: Configure Advanced vSphere Virtual Machine Settings Chapter 16

Objective 10.2: Create and Manage a Multi-site Content Library Chapter 16

Objective 10.3: Configure and Maintain a vCloud Air Connection Chapter 16

How to Take the VCP6-DCV Exam

At this time, VMware exclusively uses testing vendor Pearson Vue (www.vue.com) for delivery of all VMware career certification exams. See Chapter 17, “Final Prepa-ration,” for details on registering for the exam. Be sure to use the advice in Chapter 17 to finish your preparation prior to registering for the exam.

Who Should Take This Exam and Read This Book?

The VCP-DCV certification is the most popular certification at VMware, with more than 100,000 professionals certified around the world. This book is intended for anyone wanting to prepare for the 2V0-621 exam, which is a required exam for the certification. The audience includes IT professionals who use VMware for

Page 31: VCP6-DCV Official Cert Guide

Introduction xxxi

virtualization. This book will help prepare you for the exam by explaining the objec-tives listed in the exam blueprint.

Candidates who are preparing for the VCP6-DCV exam fall into two categories: those who currently hold a VMware Certified Professional (VCP) certification and those who are new to VMware certification (or hold only expired VCP certifica-tions). New candidates are required to take a qualifying course and pass the vSphere 6 Foundation Exam. Candidates who are holders of current VCP certification in any track (data center virtualization, desktop/mobility, cloud management or networking) and new candidates who already passed the vSphere 6 Foundation Exam are good candidates to take the VCP6-DCV exam and are the expected readers of this book.

Format of the VMware Certifi ed Professional 6—Data Center Virtualization Exam

The VCP6-DCV exam follows the same general format as the other VMware exams. When you get to the testing center and check in, the proctor will give you some general instructions and then take you into a quiet room with a PC. When you’re at the PC, you have a few things to do before the timer starts on your exam; for example, you can take a sample quiz to get accustomed to the PC and to the test-ing engine. Anyone who has user-level skills in getting around a PC should have no problems with the testing environment.

As mentioned previously, the exam is composed purely of multiple-choice questions, where each question either requires you to select a single choice or a specified num-ber of choices from a list of provided choices. See Chapter 17 for more information on the exam and advice on taking it, such as good time management.

Book Features and Exam Preparation Methods

This book uses several key methodologies to help you discover the exam topics on which you need more review, to help you fully understand and remember those details, and to help you prove to yourself that you have retained your knowledge of those topics. This book does not try to help you pass the exam only by memoriza-tion but by truly learning and understanding the topics.

The book includes many features that provide different ways to study so you can be ready for the exam. If you understand a topic when you read it but do not study

Page 32: VCP6-DCV Official Cert Guide

xxxii VCP6-DCV Official Cert Guide (Exam #2VO-621)

it any further, you probably will not be ready to pass the exam with confidence. The features included in this book give you tools that help you determine what you know, review what you know, better learn what you don’t know, and be well pre-pared for the exam. These tools include:

■ “Do I Know This Already?” Quizzes: Each chapter begins with a quiz that helps you determine the amount of time you need to spend studying that chapter.

■ Foundation Topics: These are the core sections of each chapter. They ex-plain the protocols, concepts, and configuration for the topics in that chapter.

■ Exam Preparation Tasks: This section of each chapter lists a series of study activities that should be done after reading the “Foundation Topics” section. Each chapter includes the activities that make the most sense for studying the topics in that chapter. The activities include the following:

■ Key Topics Review: The Key Topic icon appears next to the most im-portant items in the “Foundation Topics” section of the chapter. The “Key Topics Review” section lists the key topics from the chapter and their page numbers. Although the contents of the entire chapter could be on the exam, you should definitely know the information listed in each key topic. Review these topics carefully.

■ Memory Tables: To help you exercise your memory and memorize some important facts, memory tables are provided. The memory tables contain only portions of key tables provided previously in the chapter, enabling you to complete the table or list. Appendix B, “Memory Tables,” provides the incomplete tables, and Appendix C, “Memory Tables Answer Key,” includes the completed tables (answer keys). These appendixes are also provided on the Companion Website that is provided with your book.

■ Definition of Key Terms: The VCP6-DCV exam requires you to learn and know a lot of related terminology. This section lists some of the most important terms from the chapter and asks you to write a short definition and compare your answer to the Glossary.

■ Practice Exams: The companion website contains an exam engine

Page 33: VCP6-DCV Official Cert Guide

Introduction xxxiii

Companion WebsiteRegister this book to get access to the Pearson IT Certification test engine and other study materials plus additional bonus content. Check this site regularly for new and updated postings written by the authors that provide further insight into the more troublesome topics on the exam. Be sure to check the box that you would like to hear from us to receive updates and exclusive discounts on future editions of this product or related products.

To access this companion website, follow the steps below:

1. Go to www.pearsonITcertification.com/register and log in or create a new account.

2. Enter the ISBN: 9780789756480.

3. Answer the challenge question as proof of purchase.

4. Click on the “Access Bonus Content” link in the Registered Products section of your account page to be taken to the page where your downloadable con-tent is available.

Please note that many of our companion content files can be very large, especially image and video files.

If you are unable to locate the files for this title by following the steps at left, please visit www.pearsonITcertification.com/contact and select the “Site Problems/Comments” option. Our customer service representatives will assist you.

Pearson IT Certification Practice Test Engine and Questions

The companion website includes the Pearson IT Certification Practice Test engine—software that displays and grades a set of exam-realistic multiple-choice questions. Using the Pearson IT Certification Practice Test engine, you can either study by going through the questions in Study Mode, or take a simulated exam that mimics real exam conditions. You can also serve up questions in a Flash Card Mode, which will display just the question and no answers, challenging you to state the answer in your own words before checking the actual answers to verify your work.

The installation process requires two major steps: installing the software and then activating the exam. The website has a recent copy of the Pearson IT Certification Practice Test engine. The practice exam (the database of exam questions) is not on this site.

Page 34: VCP6-DCV Official Cert Guide

xxxiv VCP6-DCV Official Cert Guide (Exam #2VO-621)

Install the SoftwareThe Pearson IT Certification Practice Test is a Windows-only desktop application. You can run it on a Mac using a Windows virtual machine, but it was built specifically for the PC platform. The minimum system requirements are as follows:

■ Windows 10, Windows 8.1, or Windows 7

■ Microsoft .NET Framework 4.0 Client

■ Pentium-class 1GHz processor (or equivalent)

■ 512MB RAM

■ 650MB disk space plus 50MB for each downloaded practice exam

■ Access to the Internet to register and download exam databases

The software installation process is routine as compared with other software instal-lation processes. If you have already installed the Pearson IT Certification Practice Test software from another Pearson product, there is no need for you to reinstall the software. Simply launch the software on your desktop and proceed to activate the practice exam from this book by using the activation code included in the access code card sleeve in the back of the book.

The following steps outline the installation process:

1. Download the exam practice test engine from the companion site.

2. Respond to windows prompts as with any typical software installation process.

The installation process will give you the option to activate your exam with the acti-vation code supplied on the paper in the cardboard sleeve. This process requires that you establish a Pearson website login. You need this login to activate the exam, so please do register when prompted. If you already have a Pearson website login, there is no need to register again. Just use your existing login.

NOTE The cardboard case in the back of this book includes a piece of paper. The paper lists the activation code for the practice exam associated with this book. Do not lose the activation code. On the opposite side of the paper from the activation code is a unique, one-time-use coupon code for the purchase of the Premium Edi-tion eBook and Practice Test.

Page 35: VCP6-DCV Official Cert Guide

Introduction xxxv

Activate and Download the Practice ExamAfter the exam engine is installed, you should then activate the exam associated with this book (if you did not do so during the installation process) as follows:

1. Start the Pearson IT Certification Practice Test software from the Windows Start menu or from your desktop shortcut icon.

2. To activate and download the exam associated with this book, from the My Products or Tools tab, click the Activate Exam button.

3. At the next screen, enter the activation key from paper inside the cardboard sleeve in the back of the book. Once entered, click the Activate button.

4. The activation process will download the practice exam. Click Next, and then click Finish.

When the activation process completes, the My Products tab should list your new exam. If you do not see the exam, make sure that you have selected the My Products tab on the menu. At this point, the software and practice exam are ready to use. Simply select the exam and click the Open Exam button.

To update a particular exam you have already activated and downloaded, display the Tools tab and click the Update Products button. Updating your exams will ensure that you have the latest changes and updates to the exam data.

If you want to check for updates to the Pearson Cert Practice Test exam engine software, display the Tools tab and click the Update Application button. You can then ensure that you are running the latest version of the software engine.

Activating Other ExamsThe exam software installation process, and the registration process, only has to happen once. Then, for each new exam, only a few steps are required. For instance, if you buy another Pearson IT Certification Cert Guide, extract the activation code from the cardboard sleeve in the back of that book; you do not even need the exam engine at this point. From there, all you have to do is start the exam engine (if not still up and running) and perform Steps 2 through 4 from the previous list.

Assessing Exam ReadinessExam candidates never really know whether they are adequately prepared for the exam until they have completed about 30 percent of the questions. At that point, if you are not prepared, it is too late. The best way to determine your readiness is to work through the “Do I Know This Already?” quizzes at the beginning of each

Page 36: VCP6-DCV Official Cert Guide

xxxvi VCP6-DCV Official Cert Guide (Exam #2VO-621)

chapter and review the foundation and key topics presented in each chapter. It is best to work your way through the entire book unless you can complete each subject without having to do any research or look up any answers.

Premium Edition eBook and Practice TestsThis book also includes an exclusive offer for 70% off the Premium Edition eBook and Practice Tests edition of this title. Please see the coupon code included with the cardboard sleeve for information on how to purchase the Premium Edition.

Book OrganizationThis book contains 17 chapters, plus appendixes. The topics all focus in some way on VCP6-DCV, making the topics somewhat focused but with deep coverage on those topics:

■ Chapter 1: “Security:” This chapter discusses the security-related topics covered in the exam.

■ Chapter 2: “Networking, Part 1:” This chapter discusses advanced policies and features of network virtualization as well as verifying existing configurations.

■ Chapter 3: “Networking, Part 2:” This chapter delves into Network I/O Control (NIOC) and the changes to NIOC in vSphere 6.

■ Chapter 4: “Storage, Part 1:” This chapter provides details on how to set up and use NFS, iSCSI, FC, and FCoE protocols. This chapter also discusses how to set up and configure these protocols.

■ Chapter 5: “Storage, Part 2:” This chapter discusses VMware’s software-defined storage solutions Virtual SAN (VSAN) and Virtual Volumes (VVOL). In addition, there is a section on multipathing and failover using Pluggable Storage Architecture.

■ Chapter 6: “Storage, Part 3:” This chapter takes a closer look at file systems such as VMFS and NFS. Both of these types of file systems have different properties that affect how a datastore interacts with an ESXi Host. There is also a section on how to set up and configure Storage I/O Control (SIOC) for prioritization of virtual machines.

■ Chapter 7: “Upgrade a vSphere Deployment to 6.x:” This chapter pro-vides the information needed to upgrade the vSphere environment. Upgrading vCenter Server, ESXi Hosts, and other parts of vSphere are discussed.

Page 37: VCP6-DCV Official Cert Guide

Introduction xxxvii

■ Chapter 8: “Resource Pools:” This chapter explains the benefits of using resource pools and explores features and settings, as well as how to plan for properly utilizing them.

■ Chapter 9: “Backup and Recovery:” This chapter discusses how to provide data protection for your virtual machines using VMware Data Protection and vSphere Replication.

■ Chapter 10: “Troubleshoot Common Issues:” This chapter discusses how to troubleshoot common vSphere issues.

■ Chapter 11: “Troubleshoot Storage, Networks, and Upgrades:” This chapter discusses how to troubleshoot storage, network, and upgrade issues in vSphere.

■ Chapter 12: “Troubleshoot Performance:” This chapter discusses how to troubleshoot performance-related issues.

■ Chapter 13: “Troubleshoot Clusters:” This chapter covers the various is-sues that can occur with HA and DRS clusters, as well as fault tolerance (FT) and the changes to FT in vSphere 6.

■ Chapter 14: “Deploy and Consolidate:” This chapter looks at the many pieces involved in configuring a successful Auto Deploy environment, and the host profiles that make this possible. The chapter then discusses VMware Converter for virtualizing workloads.

■ Chapter 15: “Configure and Administer vSphere Availability Solutions:” This chapter provides information on the features of high availability (HA). Admission control and advanced cluster features are discussed in this chapter. Distributed Resource Scheduler (DRS), which is a vSphere cluster used to provide load balancing and VM placement, is also discussed.

■ Chapter 16: “Virtual Machines:” This chapter discusses advanced settings, content libraries, and vCloud Air connectors.

■ Chapter 17: “Final Preparation:” This chapter provides advice from the au-thors for final preparation. It discusses how to get ready to take the exam and tips for taking the exam.

In addition to the core chapters of the book, the book has several appendixes. Some appendixes exist in the printed book, whereas others exist on the Companion Web-site included with the book.

Page 38: VCP6-DCV Official Cert Guide

xxxviii VCP6-DCV Official Cert Guide (Exam #2VO-621)

The following appendixes are printed in the book:

■ Appendix A, “Answers to the ‘Do I Know This Already?’ Quizzes and Review Questions:” This appendix includes the answers to all the questions from Chapters 1 through 16.

The following appendixes are included on the the Companion Website:

■ Appendix B, “Memory Tables:” This appendix holds the key tables and lists from each chapter, with some of the content removed. You can print this ap-pendix and, as a memory exercise, complete the tables and lists. The goal is to help you memorize facts that can be useful on the exams.

■ Appendix C, “Memory Tables Answer Key:” This appendix contains the answer key for the exercises in Appendix B.

■ Appendix D, “Study Planner:” This appendix contains a study table to help guide the study process.

■ Glossary: The glossary contains definitions for all the terms listed in the “Define Key Terms” sections at the conclusions of Chapters 1–16.

Page 39: VCP6-DCV Official Cert Guide

This page intentionally left blank

Page 40: VCP6-DCV Official Cert Guide

This chapter covers the following objective:

■ Objective 3.1—Manage vSphere Storage Virtualization

■ Discover new storage LUNs

■ Configure FC/iSCSI/FCoE LUNs as ESXi boot devices

■ Create an NFS share for use with vSphere

■ Enable/configure/disable vCenter Server storage filters

■ Configure/edit software iSCSI initiator settings

■ Configure iSCSI port binding

■ Enable/configure/disable iSCSI CHAP

■ Determine use cases for Fibre Channel zoning

■ Compare and contrast array and virtual disk thin provisioning

Page 41: VCP6-DCV Official Cert Guide

In this chapter we will begin the first of three chapters related to storage. In vSphere storage can be either a block-based Storage Area Network (SAN) or a file-based Network Attached Storage (NAS) device. This chapter will concen-trate on the requirements and capabilities of storage devices. The SAN proto-cols that an administrator will need to know are Fibre Channel, Fibre Channel over Ethernet, and iSCSI. The NAS protocol that VMware supports is Network File System (NFS). These protocols can be enabled, modified, and deleted in different ways. In addition, there are properties and features that you will need to know for the exam.

“Do I Know This Already?” QuizThe “Do I Know This Already?” quiz allows you to assess whether you should study this entire chapter or move quickly to the “Exam Preparation Tasks” sec-tion. Regardless, the authors recommend that you read the entire chapter at least once. Table 4-1 outlines the major headings in this chapter and the corre-sponding “Do I Know This Already?” quiz questions. You can find the answers in Appendix A, “Answers to the ‘Do I Know This Already?’ Quizzes and Review Questions.”

Table 4-1 “Do I Know This Already?” Foundation Topics Section-to-Question Mapping

Foundations Topics Section Questions Covered in This Section

Discover New Storage LUNs 1, 2

Configure FC/iSCSI/FCoE LUNs as ESXi Boot Devices 3

Create an NFS Share for Use with vSphere 4

Enable/Configure/Disable vCenter Server Storage Filters 5

Enable/Disable Software iSCSI Initiator 10

Configure iSCSI Port Binding 9

Enable/Configure/Disable iSCSI CHAP 6

CHAPTER 4

Storage, Part 1

Page 42: VCP6-DCV Official Cert Guide

160 VCP6-DCV Official Cert Guide (Exam #2VO-621)

Foundations Topics Section Questions Covered in This Section

Determine Use Cases for Fibre Channel Zoning 7

Compare and Contrast Array and Virtual Disk Thin Provisioning 8

1. ESXi Host does not need a VMkernel port for which type of network adapter?

a. ESXi Host always requires a VMkernel port for iSCSI.

b. Software iSCSI initiator

c. Dependent hardware iSCSI initiator

d. Independent hardware iSCSI initiator

2. What is the best approach for discovering new storage LUNs.?

a. You do not need to do anything; storage is automatically presented to the ESXi Host.

b. To scan for new storage, select Home > Hosts and Clusters > Datacenter > right-click Storage > Rescan Storage > OK.

c. After the ESXi Host boots up, select the Scan for New Storage button.

d. Highlight the LUN, right-click, and select Scan for New Storage.

3. Which of the following is an incorrect statement?

a. In order for Fibre Channel (FC) to boot from a SAN, the /etc/vmware/fc.conf file must designate the FC adapter as a boot controller.

b. When you boot from a SAN, each ESXi Host must have exclusive access to its own boot LUN.

c. With FCoE, during the ESXi boot process, the parameters to find the boot LUN over the network are loaded into the system memory.

d. If you are using a dependent hardware iSCSI or software iSCSI initiator, you must have an iSCSI boot-capable network adapter that supports the iSCSI Boot Firmware Table (iBFT) format.

4. The virtual disks that are created on an NFS datastore are ________.

a. in a format dictated by the NFS server

b. thin provisioned

c. thick eager-zeroed

d. thick lazy-zeroed

Page 43: VCP6-DCV Official Cert Guide

Chapter 4: Storage, Part 1 161

5. vCenter Server uses storage filters to prevent LUN filtering corruption. If you need VMs to access the same LUN, then they must share the same RDM mapping file. To set up a SCSi-3 quorum disk for MSCS, which configuration parameter filter would you need to disable in the advanced settings of vSphere Client?

a. config.vpxd.filter.rdmFilter set to false

b. config.vpxd.filter.vmfsFilter set to false

c. config.vpxd.filter.rdmFilter set to true

d. config.vpxd.filter.vmfsFilter set to true

6. Which CHAP security level is not supported with Independent Hardware iSCSI?

a. Do Not Use CHAP

b. Use Unidirectional CHAP if Required by Target

c. Use Unidirectional CHAP Unless Prohibited by Target

d. Use Unidirectional CHAP

7. If you are following best practices, where should LUN masking be configured?

a. On the ESXi Host

b. On the switch

c. On the storage array

d. On vCenter Server

e. LUN masking is not supported in vSphere 6

8. Which statement about thin provisioning is incorrect?

a. When a thin virtual disk is created, it does not preallocate capacity and does not zero out the data block on the VMFS file system.

b. When you use Storage vMotion, there is an option to enable thin provisioning on a storage array.

c. When writes occur and more space is needed, the VMkernel grows storage for VMFS 1 MB at a time.

d. If the file system is NFS, which is by default thin provisioned, it grows 4 KB at a time.

Page 44: VCP6-DCV Official Cert Guide

162 VCP6-DCV Official Cert Guide (Exam #2VO-621)

9. Which of the following statement about iSCSI port binding is incorrect?

a. You need to associate a VMkernel port with a specific iSCSI adapter in order to configure iSCSI port binding.

b. For multipathing purposes, it is best to have two active network adapters connected to one VMkernel port.

c. The iSCSI initiator for an ESXi Host can be either hardware or software based.

d. Best practices say to designate a separate network adapter for iSCSI; this is done for performance and security.

10. Which of the following statements about iSCSI initiators is incorrect?

a. The steps to enable a software iSCSI initiator begin with browsing to the host using the vSphere Web Client. Click Manage > Storage > Storage Adapters > Add.> Storage > Storage Adapters > Add.

b. You need to activate a minimum of two software iSCSI adapters on each host.

c. If the iSCSI software adapter was used to boot the ESXi Host, it will be reenabled the next time the host boots.

d. The steps to disable the software iSCSI initiator begin with browsing to the host using the vSphere Web Client. Click the Manage tab and then click Storage. Click Storage Adapters and then highlight the iSCSI software adapter that you want to disable.

Page 45: VCP6-DCV Official Cert Guide

Chapter 4: Storage, Part 1 163

Foundation Topics

Objective 3.1—Manage vSphere Storage VirtualizationThis section provides details on how to set up and use storage area network (SAN) and network access server (NAS) storage in a virtualized environment. vSphere stor-age virtualization combines APIs and features built into vSphere, which abstracts the physical layer of storage into storage space that can be managed and utilized by virtual machines. A virtual machine (VM) uses a virtual disk or disks to store files that it needs to run an operating system and an application or applications. The files comprising a virtual machine are detailed in Chapter 16, “Virtual Machines.” One of the files that encompass a VM is a virtual disk, which contains the data for the VM.

This chapter concentrates on SAN- and NAS-based storage. A SAN is a block-based storage protocol that makes data available over the Ethernet or Fibre Channel network, using the Fibre Channel, FCoE, or iSCSI protocols. On the other hand, a NAS is a file-based storage system that makes data available over an Ethernet net-work, using the Network File System (NFS) protocol. Both a SAN and a NAS are shared devices that connect to an ESXi Host through a network or storage adapter. Now let’s discuss how to configure and manage these shared storage protocols.

Storage Protocols

Storage is a resource that vSphere uses to store virtual machines. Four main pro-tocols can be used within vSphere: Fibre Channel (FC), Fibre Channel over Ethernet (FCoE), Internet Small Computer System Interface (iSCSI), and Net-work File System (NFS). These protocols can be used to connect the ESXi Host with a storage device.

Identify Storage Adapters and Devices

A storage adapter connects the ESXi Host and a storage SAN/NAS device. There are different adapters, and interaction is dependent on how much intelligence is built into the card. Some adapters have firmware or integrated circuitry on the card that can improve performance between the ESXi Host and the storage device. A VM resides on a storage device and needs a software driver to control communica-tion with the ESXi Host. No matter which protocol you use, the VM residing on the storage device relies on a SCSI device driver to communicate to the ESXi Host. The VM uses a virtual SCSI controller to access the virtual disks of the virtual ma-chine. One factor that determines which storage adapter to use is what protocol is being utilized for the communication between the ESXi Host and the storage device. Before we discuss each of the storage protocols, this chapter shows how to

Page 46: VCP6-DCV Official Cert Guide

164 VCP6-DCV Official Cert Guide (Exam #2VO-621)

find the storage adapters and devices within vSphere using the vSphere Web Client. Then it describes each of these protocols and identifies important characteristics to consider when using each of these options.

NOTE You cannot use IDE/ATA or USB drives to store virtual machines that are powered on in vSphere 6.

Display Storage Adapters for a Host

The procedure to display all of a host’s storage adapters using the vSphere Web Cli-ent is to highlight the ESXi Host in the hosts and clusters inventory. Then click the Manage tab, click Storage, and select Storage Adapters. In Figure 4-1 you can see four adapters. The last listed adapter, vmhba33, is a software-based iSCSI initiator.

Storage Adapters

Figure 4-1 Storage Adapters

Storage Devices for an Adapter

Figure 4-1 shows connections between storage and the ESXi Host. You can have multiple storage devices reserved, and they can contain VMs. One method to dis-tinguish one storage device from another is to use a logical unit number (LUN). A LUN is the identifier of a device that is being addressed by the SCSI protocol or similar protocols, such as Fibre Channel and iSCSI. The protocol may be used with any device that supports read/write operations, such as a tape drive, but the term is most often used to refer to a disk drive, and these terms are, in fact, often used syn-onymously. Tapes, CD-ROMs, and even scanners and printers can be connected to a SCSI bus and may therefore appear as LUNs.

Page 47: VCP6-DCV Official Cert Guide

Chapter 4: Storage, Part 1 165

A VMware VMDK (Virtual Machine Disk) becomes a LUN when it is mapped to a VM using the virtual SCSI adapter. LUN is one of the many terms that are used incorrectly most of the time. A SAN is structured just the same way as a traditional SCSI bus except that the old ribbon cable has been replaced with a network. This is why LUN masking is needed: SCSI is a master/slave architecture (initiator/target), and there is no authentication mechanism in the SCSI protocol to dictate which hosts can acquire a particular LUN; hence LUN masking “masks” (hides) LUNs from all hosts except the ones it is configured for.

The procedure to display a list of storage devices for a storage adapter on an ESXi Host is to highlight the ESXi Host in the hosts and clusters inventory. Then click the Manage tab, click Storage, and select Storage Adapters. Once you select the storage adapter, the storage devices that can be accessed through the adapter are dis-played in the Adapter Details section by selecting Devices. In Figure 4-2, the iSCSI software adapter has been selected and is displaying three iSCSI LUN devices .

Devices

Figure 4-2 Available iSCSI LUNs

NOTE The same LUN cannot be presented to an ESXi Host through different stor-age protocols, such as iSCSI and Fibre Channel.

Page 48: VCP6-DCV Official Cert Guide

166 VCP6-DCV Official Cert Guide (Exam #2VO-621)

Fibre Channel Protocol

Fibre Channel (FC) is a transport layer that can be used to transmit data on a SAN. Many devices can communicate with each other on a SAN, such as switches, hubs, initiator HBAs, and storage adapters using the Fibre Channel Protocol (FCP). The protocol has been around since the mid-1980s, so it is a well understand topology, and it has been popular due to its excellent performance. Fibre Channel replaced Small Computer Systems Interface (SCSI) as the primary means of host-to-storage communication. In order to facilitate the compatibility, the FC frame encapsulates the SCSI protocol. Thus, FC is moving SCSI packets around its network.

The terms initiator and target were originally SCSI terms. FCP connects the actual initiator and target hardware, which must log into the fabric and be properly zoned (like VLANs) for storage discovery by the ESXi Host. The host operating system communicates via SCSI commands with the disk drives in a SAN. The cabling that FC uses can be either copper cables or optical cables. Using optical cables, the SCSI protocol is serialized (that is, the bits are converted from parallel to serial, one bit at a time) and transmitted as light pulses across the optical cable. Data runs at the speed of light, without the limitations of short-distance SCSI cables. Fibre Channel is like a SAN highway where other protocols such as SCSI and IP can drive.

Fibre Channel over Ethernet Protocol

The Fibre Channel over Ethernet (FCoE) is a protocol that takes a Fibre Channel (FC) packet and puts it over an Ethernet network of 10 Gbps or higher speeds. Each FC frame is encapsulated into an Ethernet frame with a one-to-one mapping. ESXi servers connect to a SAN fabric using host bus adapters (HBAs). Connectivity to FCoE fabrics is enabled through converged network adapters (CNAs). Each HBA/CNA can run as either an initiator (ESXi Host) or a target (storage array). Each adapter has a global unique address referred to as a World Wide Name (WWN). Each WWN must be known in order to configure LUN access on a NetApp stor-age array.

iSCSI Protocol

The Internet Small Computer System Interface (iSCSI) protocol provides access to storage devices over Ethernet-based TCP/IP networks. iSCSI enables data transfers by carrying SCSI commands over an IP network. Routers and switches can be used to extend the IP storage network to the wide area network—or even through the Internet with the use of tunneling protocols. The iSCSI protocol establishes com-munication sessions between initiators (clients) and targets (servers). The initiators are devices that request commands be executed. Targets are devices that carry out the commands. The structure used to communicate a command from an application

Page 49: VCP6-DCV Official Cert Guide

Chapter 4: Storage, Part 1 167

client to a device server is referred to as a Command Descriptor Block (CDB). The ba-sic functions of the SCSI driver are to build SCSI CDBs from requests issued by the application and forward them to the iSCSI layer.

NFS Protocol

The Network File System (NFS) service lets you share files over a network between a storage device and an ESXi Host. The files are centrally located on the NFS server, which enables the NFS client access using a client/client architecture. The NFS server is the storage array, and it provides not only the data but also the file system. The NFS client is the ESXi Host, and the client code has been built into the VMkernel since 2002, running NFS version 3. Because the NFSv3 client is au-tomatically loaded into the ESXi Host, it was the only version of NFS that VMware supported. What is new in vSphere 6.0 is that VMware reworked the source code to add support for both NFSv3 and NFSv4.1. NFS version 4.1 adds additional features that aid in interactions between the storage and the ESXi Host.

Authentication NFSv4.1 with Kerberos Authentication

NFSv4.1 supports both Kerberos and non-root user authentication. With NFSv3, remote files are accessed with root permissions, and servers have to be configured with the no_root_squash option to allow root access to files. This is known as an AUTH_SYS mechanism.

Native Multipathing and Session Trunking

The ability to add multiple IP addresses associated with a single NFS mount for re-dundancy is known as session trunking, or multipathing. In the server field, you add a comma to separate the IP addresses in a list to do load balancing or multipathing.

In-band, Mandatory, and Stateful Server-Side File Locking

In NFSv3 VMware does not use the standard lockd daemon because of how VMware’s high availability conflicts with the standard server lock daemon. Thus, in NFSv3, VMware uses its own client-side locking mechanism for file locking. In NFSv4.1, VMware now uses the standard server-side lockd daemon.

NOTE vSphere 6.0 does not support pNFS (parallel NFS), which is a feature of NFSv4.1.

Page 50: VCP6-DCV Official Cert Guide

168 VCP6-DCV Official Cert Guide (Exam #2VO-621)

Identify Storage Naming Conventions

In the previous sections, you have learned that various protocols can be presented to vSphere. If you want to create a virtual machine, you need a place to store the vir-tual machine files, and thus you need a datastore. The naming convention is based on which protocol you use. In order to create a datastore, you need to ask the stor-age administrator to create either a LUN or an NFS server. If you are using local drives, iSCSI, or Fibre Channel, then the device naming begins with vmhba. If you are using NFS, the device naming includes the NFS export name. Each LUN or storage device can be identified by several names.

The procedure to display the storage paths using the vSphere Web Client is to highlight the ESXi Host in the hosts and clusters inventory. Then click the Manage tab, click Storage, and select Storage Adapters. Once you select the storage adapter, the storage devices that can be displayed through the adapter are displayed in the Adapter Details section when you select Paths. In Figure 4-3 the iSCSI software adapter is selected and showing three iSCSI LUN devices:

Paths

Figure 4-3 Displaying iSCSI LUN Paths

Page 51: VCP6-DCV Official Cert Guide

Chapter 4: Storage, Part 1 169

■ Runtime name: vmhbaAdapter:CChannel:TTarget:LLUN

■ vmhbaAdapter is the name of the storage adapter. The name refers to the physical adapter on the host, not to the SCSI controller used by the vir-tual machine. In vmhba in Figure 4-3, vm refers to the VMkernel, and hba is the host bus adapter.

■ CChannel is the storage channel, if the adapter has multiple connections, the first channel is channel 0. Software iSCSI adapters and dependent hardware adapters use the channel number to show multiple paths to the same target.

■ TTarget is the target number. The target number might change if the mappings of targets visible to the host change or if the ESXi Host reboots.

■ LLun is the LUN, which shows the position of the LUN within the tar-get. If a target has only one LUN, the LUN is always 0.

For example, vmhba2:C0:T2:L3 would be LUN 3 on target 2, accessed through the storage adapter vmhba2 and channel 0.

■ The target name shows the Network Address Authority (NAA) ID, which can appear in different formats, based on the device itself. In Figure 4-3, the target name is for a software-based iSCSI device that is using the iqn scheme.

■ LUN number: This is the LUN for the device.

To display all device names using the CLI, type in the following command (see Figure 4-4):

# esxcli storage core device list

Page 52: VCP6-DCV Official Cert Guide

170 VCP6-DCV Official Cert Guide (Exam #2VO-621)

naa. 600a09807737555a473f476b466b5778

Display Name: NETAPP iSCSI Disk (naa. 600a09807737555a473f476b466b5778)

Figure 4-4 Use the CLI to Display Storage Device Information

Identify Hardware/Dependent Hardware/Software iSCSI Initiator Requirements

The ESXi Host uses the iSCSI protocol to access LUNs on the storage system and is the initiator over a standard Ethernet interface. The host needs a network adapter to send and receive the iSCSI packets over TCP/IP. There are three iSCSI initiator options available, as shown in Figure 4-5:

Figure 4-5 iSCSI Initiators

Page 53: VCP6-DCV Official Cert Guide

Chapter 4: Storage, Part 1 171

■ Software iSCSI initiator: A software iSCSI initiator is a standard 1 GbE or 10 GbE NIC. There is nothing special about the network interface. A Send Targets command creates an iSCSI session between the initiator and the tar-get on TCP port 3260. The VMkernel on the ESXi Host is responsible for discovering the LUNs by issuing the Send Targets request.

■ Dependent hardware iSCSI initiator: A dependent hardware iSCSI initia-tor is a network interface card that has some built-in intelligence. It could be a chip or firmware, but either way, the card can “speak” iSCSI, which means the TCP offload function is on the card. However, not everything is done on the NIC; you must configure networking for the iSCSI traffic and bind the adapter to an appropriate VMkernel iSCSI port.

■ Independent hardware iSCSI initiator: An independent hardware iSCSI initiator handles all network and iSCSI processing and management for the ESXi Host. For example, QLogic makes adapters that provide for the discov-ery of LUNs as well as the TCP offload engine (TOE). The ESXi Host does not need a VMkernel port for this type of card. This type of card is more ex-pensive than the other types of NICs, but it also gets better performance.

Discover New Storage LUNs

When an ESXi Host boots up, it scans or sends a signal down its bus path, which discovers all the LUNs that are connected to the host. Then the host stops scanning for any new LUNs. I like to think of the host as being on siesta, taking a break from scanning for any new LUNs. While the host is on siesta, if the storage administra-tor presents any new LUNs to the ESXi Host, they will not be seen. So you need to wake up the ESXi Host by selecting Rescan Storage, as shown in Figure 4-6.

Figure 4-6 Rescan Storage

Page 54: VCP6-DCV Official Cert Guide

172 VCP6-DCV Official Cert Guide (Exam #2VO-621)

After you click OK, a new box pops up, with check boxes for Scan for New Stor-age Devices (to scan all host bus adapters looking for new LUNs) and Scan for New VMFS Volumes (to rescan all known storage devices for new VMFS volumes that have been added since the last scan).

Configure FC/iSCSI/FCoE LUNs as ESXi Boot Devices

You can set up your ESXi Host to boot from a FC or iSCSI LUN instead of boot-ing from a local hard disk. The host’s boot image is stored on the LUN that is being used exclusively for that ESXi Host. Thus, vSphere supports an ESXi Host’s ability to boot from a LUN on a SAN. The ability of an ESXi Host to boot from a SAN is sup-ported using FC and iSCSI. This capability does require that each host have unique access to its own LUN. You also need to enable the boot adapter in the host BIOS.

NOTE When you boot from a SAN, each host must have its own boot LUN.

FC

In order for a Fibre Channel (FC) device to boot from a SAN, the BIOS of the FC adapter must be configured with the World Wide Name (WWN) and LUN of the boot device. In addition, the system BIOS must designate the FC adapter as a boot controller.

iSCSI

It is possible to boot an ESXi Host using an independent hardware iSCSI, depen-dent hardware iSCSI, or software iSCSI initiator. If your ESXi Host uses an inde-pendent hardware iSCSI initiator, you need to configure the adapter to boot from the SAN. How you configure the adapter varies, depending on the vendor of the adapter.

If you are using a dependent hardware iSCSI or software iSCSI initiator, you must have an iSCSI boot-capable network adapter that supports the iSCSI Boot Firm-ware Table (iBFT) format. iBFT is a protocol defined in Advanced Configuration and Power Interface (ACPI) that defines parameters used to communicate between the storage adapter and the operating system. This is needed because the ESXi Host needs to load up enough information from the firmware to discover the iSCSI LUN over the network.

Page 55: VCP6-DCV Official Cert Guide

Chapter 4: Storage, Part 1 173

FCoE

You can boot an ESXi Host from a Fibre Channel over Ethernet (FCoE) network adapter. The FCoE initiator must support the FCoE Boot Firmware Table (FBFT) or FCoE Boot Parameter Table (FBPT). During the ESXi boot process, the param-eters to find the boot LUN over the network are loaded into the system memory.

Create an NFS Share for Use with vSphere

The Network File System (NFS) is a client/server service that allows users to view, store, and modify files on a remote system as though they were on their own local computer. NFS allows systems of different architectures running different operat-ing systems to access and share files across a network. The ESXi Host is the NFS client, while typically a SAN device such as EMC or NetApp acts as an NFS server. The NFS server shares the files, and the ESXi Host accesses the shared files over the network. How you create an NFS server and set up NFS shares depend on the system that is being used as the NFS server.

Enable/Configure/Disable vCenter Server Storage Filters

vCenter Server provides storage filters to avoid presenting storage that should be avoided due to performance problems or unsupported storage devices. The vSphere environment provides four storage filters that can affect the action of the vCenter Server when scanning storage. Without these filters, when vCenter Server is scan-ning for storage, all storage that is found could be presented to vSphere, even if it is in use. The filters prevent this type of unwanted activity. However, some specific use cases can affect what storage devices are found during scanning. By default, the storage filters are set to true and are designed to prevent specific storage datastore problems. Except in certain situations, it is best to leave the storage filters in their enabled state. Table 4-2 displays the vCenter Server storage filters and their respec-tive Advanced Setting keys:

Table 4-2 vCenter Server Storage Filters

Filter Advanced Setting Key

RDM config.vpxd.filter.rdmFilter

VMFS config.vpxd.filter.vmfsFilter

Host Rescan config.vpxd.filter.hostRescanFilter

Same Host and Transports config.vpxd.filter.SameHostAndTransportsFilter

Page 56: VCP6-DCV Official Cert Guide

174 VCP6-DCV Official Cert Guide (Exam #2VO-621)

■ RDM filter: Filters out LUNs that have been claimed by any RDM on any ESXi Host managed by vCenter Server. This storage filter can be used in a situation such as when using Microsoft Cluster Server. When set to false, the filter is disabled, allowing a LUN to be added as an RDM, even though the LUN is already being utilized as an RDM by another VM. To set up a SCSI-3 quorum disk for MSCS, this storage filter needs to be disabled.

■ VMFS filter: Filters out LUNs that have been claimed and VMFS formatted on any ESXi Host managed by vCenter Server. Thus, in the vSphere client, when you go to the Add Storage Wizard, you do not see any VMFS-formatted LUNs. If the setting is switched to false, the LUN is seen as available by the vSphere Client, and any ESXi Host could attempt to format it and claim it .

■ Host Rescan filter: By default, when a VMFS volume is created, an auto-matic rescan occurs on all hosts connected to the vCenter Server. If the setting is switched to false, the automatic rescan is disabled when creating a VMFS datastore on another host. For example, you could run a PowerCLI cmdlet to add 100 datastores; you should wait until the cmdlet is finished before scan-ning all the hosts in the cluster.

■ Same Host and Transports filter: Filters out LUNs that cannot be used as VMFS datastore extents due to host or storage incompatibility. If the setting is switched to false, an incompatible LUN could be added as an extent to an ex-isting volume. An example of an incompatible LUN would be adding a LUN as an extent that is not seen by all of the hosts.

As an example, the Host Rescan filter could be set to false to stop an automatic rescan when you create a new datastore. Since you are going to run a PowerCLI cmdlet to add 100 datastores, you would want to turn this off until the cmdlet is finished running. Thus, after the 100 datastores are added, you could scan to dis-cover all of the new storage. Figure 4-7 displays the vCenter Advanced Settings screen, which is where storage filters can be enabled. The steps to turn off the filter begin by using the vSphere Web Client navigator and starting at Home and select-ing Hosts and Clusters. Then highlight your vCenter Server, click the Manage tab, and click Settings. To disable a filter, first add it by clicking Advanced Set-tings and then Edit. This opens the Edit Advanced vCenter Server Settings win-dow. At the bottom of the window, in the Key box, type in the storage filter config.vpxd.filter.hostRescanFilter and add the Value false to enable the storage filter, as shown in Figure 4-7.

Page 57: VCP6-DCV Official Cert Guide

Chapter 4: Storage, Part 1 175

Figure 4-7 Enable a Storage Filter

iSCSI

vSphere provides support for several different methods of booting up using an iSCSI LUN. An independent hardware iSCSI adapter, such as a QLogic iSCSI HBA, first needs to boot from the VMware installation media, which loads an iSCSI HBA configuration menu. The HBA config menu allows you to configure host adapter settings .

In addition to the independent hardware adapter, the ESXi Host can boot from a software adapter or dependent hardware iSCSI adapter. The network adapter must support the iSCSI Boot Firmware Table (iBFT) format to deploy an ESXi Host from an iSCSI SAN. The iBFT allows for communicating parameters about the iSCSI boot device to an operating system.

Configure/Edit Hardware/Dependent Hardware Initiators

A hardware initiator or a dependent initiator is a network adapter that has either firmware or a chip built in to the adapter that speaks iSCSI. The network adapter can handle standard networking as well as the iSCSI offload engine. After you install the hardware initiator, it appears in the list of network adapters. However, you need to associate a VMkernel port with the adapter before you can configure the iSCSI settings.

Page 58: VCP6-DCV Official Cert Guide

176 VCP6-DCV Official Cert Guide (Exam #2VO-621)

Enable/Disable Software iSCSI Initiator

A software iSCSI initiator is a standard 1 GB or 10 GB network adapter. It is sim-ply a supported adapter, but nothing on the physical card is designed with SCSI in mind. The network adapter relies on the VMkernel to handle discovery and sends the processing of encapsulation and de-encapsulation of network packets up to the kernel. You need to activate only one software iSCSI adapter on the ESXi Host.

Enable a Software iSCSI Initiator

The steps to enable the software iSCSI initiator begin with browsing to the host using the vSphere Web Client. Click the Manage tab and then click Storage. Click Storage Adapters and then click Add. As you can see in Figure 4-8, select Software iSCSI Adapter and confirm that you want to add the driver to your ESXi Host.

Software iSCSI adapter

Figure 4-8 Enable a Software iSCSI Initiator

Disable a Software iSCSI Initiator

The steps to disable the software iSCSI initiator begin with browsing to the host using the vSphere Web Client. Click the Manage tab and then click Storage. Click Storage Adapters and then highlight the iSCSI software adapter that you want to disable. Underneath Storage Adapters is the Adapter Details section; click Properties and click the Disable button. Disabling the adapter marks it for removal, but the adapter is not removed until the next host reboot. Figure 4-9 shows the iSCSI initiator being disabled. After you reboot the host, the iSCSI adapter no longer appears in the list of storage adapters.

Page 59: VCP6-DCV Official Cert Guide

Chapter 4: Storage, Part 1 177

vmhba33

Disable

Figure 4-9 Disable a Software iSCSI Initiator

Configure/Edit Software iSCSI Initiator Settings

There are several different settings you can make on an iSCSI initiator. The set-tings can be configured in the Adapter Details section. One option is to enable and disable paths for the iSCSI adapter. Another option when you are editing an iSCSI initiator is to use dynamic or static discovery. With dynamic discovery, the iSCSI initiator sends a Send Targets request to the storage array, which returns a list of available targets to the initiator. The other option is to use static discovery, where you manually add targets. Also, you can set up CHAP authentication, which is dis-cussed in an upcoming section of this chapter.

Determine Use Case for Hardware/Dependent Hardware/Software iSCSI Initiator

A good reason to use a software iSCSI initiator is that you do not need to purchase a specialized network adapter. You only need to buy a standard 1 GB or 10 GB net-work adapter. Another reason you might use a software initiator is that it is the only initiator that supports bidirectional CHAP.

NOTE If the iSCSI software adapter was used to boot the ESXi Host, it is reenabled the next time the host boots.

Page 60: VCP6-DCV Official Cert Guide

178 VCP6-DCV Official Cert Guide (Exam #2VO-621)

The benefit of a dependent hardware iSCSI initiator is that part of the processing happens on the network adapter and part on the CPU. The adapter offloads iSCSI processing to the adapter, which speeds up processing of the iSCSI packets. It also reduces CPU overhead because only part of the processing of the iSCSI packets happens on the CPU, and part happens on the network adapter.

You use an independent hardware iSCSI initiator when performance is most impor-tant. This adapter handles all its own networking, iSCSI processing, and management of the interface.

Configure iSCSI Port Binding

For most implementations, iSCSI storage is connected to the ESXi Hosts and is used to host virtual machines. The ESXi Host is then considered to be the initia-tor because it is requesting the storage, and the iSCSI storage device is considered the target because it is delivering the storage. The initiator for the ESXi Host can be software or hardware based. A software iSCSI initiator is included and built in to the VMkernel. When using a software iSCSI initiator, a standard 1 GB or 10 GB network adapter is used for storage transport. You might have multiple network adapters, and iSCSI port binding enables you to specify the network interface that iSCSI can use.

NOTE iSCSI ports of the storage array must reside in the same broadcast domain and IP subnet as the VMkernel adapters.

A VMkernel port must be configured on the same network as the storage device to use the software iSCSI initiator. This is because you need to associate a VMkernel port with a specific iSCSI adapter in order to configure iSCSI port binding. The initiator uses the first network adapter port it finds that can see the storage device and use it exclusively for transport. This means that just having multiple adapter ports is not enough to balance storage workloads. However, you can achieve load balancing by configuring multiple VMkernel ports and binding them to multiple adapter ports.

After you load the software iSCSI kernel module, the next step is to bind the iSCSI driver to a port. There is a one-to-one relationship between the VMkernel port and the network adapter. This is a requirement for iSCSI port binding and multipath-ing. Only one port can be in the active state for a VMkernel adapter. Because only one port can be in the active state, you need to make sure that all other ports are set to Unused.

Page 61: VCP6-DCV Official Cert Guide

Chapter 4: Storage, Part 1 179

From the Home page, go to Hosts and Clusters. Select the ESXi Host in the in-ventory, click the Manage tab, and click the Networking tab. Choose the virtual switch that you want to use to bind the VMkernel port to a physical adapter. Next, choose the VMkernel adapter by highlighting the network label as shown in Figure 4-10 (step 1), which turns the VMkernel adapter blue. Then click the Edit Settings icon, shown as step 2 in Figure 4-10, which opens the Edit Settings window.

2. Edit Settings

1. Edit VMkernel

Figure 4-10 Select the VMkernel Port to Bind

The final step is to bind the VMkernel port to a network adapter. This can be ac-complished by selecting the override switch failover order option, where one port is active and all of the other ports are set to the Unused state. The Edit Settings for the iSCSI VMkernel adapter then appear. To modify the vmnics, click Teaming and Failover. Select the check box for failover order Override. Then highlight all vmnics except for the one vmnic that will remain active. Move all other vmnics to Unused adapters using the blue down arrow. Then click OK.

NOTE Designate a separate network adapter for iSCSI for performance and security.

Page 62: VCP6-DCV Official Cert Guide

180 VCP6-DCV Official Cert Guide (Exam #2VO-621)

Enable/Configure/Disable iSCSI CHAP

There is an optional security feature you can enable for iSCSI, called Challenge Handshake Authentication Protocol (CHAP). CHAP is a method for authenticating the ESXi Host and a storage device using password authentication. The authenti-cation can be either one-way (unidirectional CHAP) or two-way (bidirectional, or mutual, CHAP):

■ Unidirectional: Also called one-way CHAP. The storage array or target au-thenticates the ESXi Host or initiator. With unidirectional CHAP, the ESXi Host does not authenticate the storage device. The ESXi Host authenticates by sending the CHAP secret to the storage target.

■ Bidirectional: Also called mutual CHAP. Authentication is done both ways, and the secret is different in the two directions. vSphere supports this method for software and dependent hardware iSCSI adapters only.

CHAP is a three-way handshake used to authenticate the ESXi Host, and bidirec-tional CHAP also authenticates the storage array. The CHAP secret is nothing more than a password. For both software iSCSI and dependent hardware iSCSI initiators, ESXi also supports per-target CHAP authentication.

As shown in Figure 4-11, in order to enable and configure iSCSI CHAP on ESXi Host, begin at Home then Hosts and Clusters and select the host on which you want to configure CHAP. Then select Manage, click Storage, and then Storage Adapters. Highlight iSCSI Software Adapter, and in the Adapter Details section, select the Properties tab and click the Edit button for authentication to set up CHAP.

Page 63: VCP6-DCV Official Cert Guide

Chapter 4: Storage, Part 1 181

Edit

Figure 4-11 iSCSI CHAP’s Edit Button

The CHAP authentication method needs to match the storage array’s CHAP im-plementation and is vendor specific. You need to consult the storage array’s docu-mentation to help determine which CHAP security level is supported. When you set up the CHAP parameters, you need to specify which security level for CHAP should be utilized between the ESXi Host and the storage array. The different CHAP security levels, descriptions, and their corresponding supported adapters are listed in Table 4-3.

Table 4-3 CHAP Security Levels

CHAP Security Level Description Supported

None CHAP authentication is not used. Select this option to disable authentication if it is currently enabled.

Software iSCSI

Dependent hardware iSCSI

Independent hardware iSCSI

Use Unidirectional CHAP if Required by Target

Host prefers non-CHAP connection but can use CHAP if required by the target.

Software iSCSI

Dependent hardware iSCSI

Use Unidirectional CHAP Unless Prohibited by Target

Host prefers CHAP but can use non-CHAP if the target does not support CHAP.

Software iSCSI

Dependent hardware iSCSI

Independent hardware iSCSI

Page 64: VCP6-DCV Official Cert Guide

182 VCP6-DCV Official Cert Guide (Exam #2VO-621)

CHAP Security Level Description Supported

Use Unidirectional CHAP Host requires CHAP authentication. The connection fails if CHAP negotiation fails.

Software iSCSI

Dependent hardware iSCSI

Independent hardware iSCSI

Use Bidirectional CHAP Host and target both support bidirectional CHAP.

Software iSCSI

Dependent hardware iSCSI

To configure CHAP, after selecting the Properties tab, click the Edit button to open up the Edit Authentication window, as shown in Figure 4-12. This is where you set up CHAP to authenticate. Keep in mind that CHAP does not encrypt any-thing; the communication between the initiator and target are in the clear. The CHAP name should not exceed 511 alphanumeric characters, and the CHAP secret should not exceed 255 alphanumeric characters. Also note that some hardware-based iSCSI initiators might have lower limits. For example, the QLogic adapter limits the CHAP name to 255 alphanumeric characters and the CHAP secret to 100 alphanumeric characters.

Figure 4-12 CHAP Setup Options

Page 65: VCP6-DCV Official Cert Guide

Chapter 4: Storage, Part 1 183

Determine Use Cases for Fibre Channel Zoning

One goal in storage is to make sure the host communicates with the correct storage and the storage communicates with the correct host. This can be challenging be-cause many devices and nodes can be attached to a SAN. FC and FCoE switches use zoning and LUN masking to isolate communication between ESXi Hosts and stor-age devices. Zoning blocks communication between targets and initiators to isolate traffic to scan only devices that should be seeing each other. There are two kinds of zoning: hard zoning, which uses the physical switch port IDs, and soft zoning, which uses the WWPNs of the initiators and targets. Hardware and software zoning both attempt to reduce the number of targets and LUNs presented to the host. The best practice with LUN masking is to configure it on the storage array. The stor-age administrator configures which hosts have access to a LUN using masking. As a VMware best practice, LUN masking should be done on the ESXi Host using CLI but not in the vSphere client.

Compare and Contrast Array and Virtual Disk Thin Provisioning

Thin provisioning involves presenting more storage space to the hosts connecting to the storage system than is actually available on the storage system. For example, say that a storage system has usable capacity of 500 GB. The storage administrator then presents two hosts, each with a LUN of 300 GB. The mapping of these two LUNs means the storage array is presenting more storage to both hosts than is physically available on the storage array. When a LUN is created, the storage array does not dedicate specific blocks out of the volume for the LUN at the time of provisioning; rather, blocks are allocated when the data is actually written to the LUN. In this way, it is possible to provision more storage space, as seen from the connected ESXi Hosts, than actually physically exists in the storage array.

Array Thin Provisioning

ESXi supports thin-provisioned LUNs. Array thin provisioning simply means that the thin provisioning is done on the storage array, which reports the LUN’s logical size instead of the real physical capacity of the LUN. When a LUN is thin provisioned, the storage array does not assign specific blocks for the LUN; instead, it waits until blocks are going to be written to zero out the data blocks and then performs the write. The storage array vendor uses its own file system and bookkeeping for the LUN, thus filling the LUN capacity on demand and saving storage space. By prom-ising more storage space than the LUN actually has, you can overallocate storage. One built-in advantage that many storage array vendors have is the ability to grow the volume automatically when it is running out of space. Many storage vendors have automatic processes to grow the volume or delete certain file system constructs such as array-based snapshots.

Page 66: VCP6-DCV Official Cert Guide

184 VCP6-DCV Official Cert Guide (Exam #2VO-621)

Virtual Disk Thin Provisioning

When a thin virtual disk is created, it does not preallocate capacity, and it does not zero out the data block on the VMFS file system and the backend storage. Instead, the virtual disk consumes storage space only when data is required due to write to a disk. Initially, the VMDK’s actual space usage starts out small and grows as more writes to disk occur. However, the guest OS sees the full allocated disk size at all times. The VMDK hides from the guest OS the fact that it is has not actu-ally claimed all of the data blocks. The virtual machine’s disk consumes only the amount of space that is needed for the current files in the file system. When writes occur and more space is needed, the VMkernel grows storage for VMFS 1 MB at a time. So as writes are committed and the 1 MB data block fills up, another 1 MB is allocated to the virtual disk. If the file system is NFS, which is by default thin provisioned, it grows 4 KB at a time, which is the size of its data block. Since the VMFS datastore is shared, SCSI locking needs to be performed by VMware vStor-age API for Array Integration (VAAI). The metadata operation of SCSI locking is accomplished by VAAI.

To put array-based and virtual disk thin provisioning into perspective, the new data block or blocks need to be zeroed out when you are working with a virtual thin disk and new writes occur. However, before this operation can occur, the thin disk might have to obtain additional capacity from the datastore. Therefore, the storage ar-ray’s math depends on how much space it has available compared to the ESXi Host. Thus, the thin provisioning is working at different levels.

Determine Use Case for and Configure Array Thin Provisioning

The ESXi Host can use storage arrays that present thin-provisioned storage. When a LUN is thin provisioned, it reports the logical size of the LUN and not its actual physical size. The storage array can promise more storage than its physical capac-ity. For example, an array may report that the LUN has 3 TB of space, when it really physically has 2 TB of disk space. The VMFS datastore is going to believe it has 3 TB of disk space that it can use. Thin provisioning is useful in virtual desktop environments where the system disk is shared among a number of users. You can save money by not having to reserve storage for each desktop’s system disk. On the server side, thin provisioning can also be useful when you want to save money. However, be careful to monitor growth because running out of space with certain types of applications can be hazardous to your employment.

NOTE Array-based thin provisioning is dependent on the storage array itself. If the LUN becomes full, the storage array decides what action to take. It is most likely to go offline. ESXi does not support enabling and disabling of thin provisioning on a storage devic e.

Page 67: VCP6-DCV Official Cert Guide

Chapter 4: Storage, Part 1 185

SummaryYou have now read the chapter covering exam topics on storage. You should use in-formation in the following sections to complete your preparation for Objective 3.1.

Exam Preparation Tasks

Review All the Key TopicsTable 4-4 provides a reference to each of the key topics identified in this chapter. Take a few moments to review each of these specific items.

Table 4-4 Key Topics for Chapter 4

Key Topic Element Description Pages

Note No IDE/ATA/USB support to store VMs 164

Figure 4-1 Displaying storage adapters 164

Note LUN presentation 165

Figure 4-2 iSCSI LUNs that are available 165

Note Parallel NFS not supported 167

Figure 4-3 Displaying iSCSI LUN paths 168

Figure 4-4 Using CLI to display storage device information 170

Figure 4-5 iSCSI initiators 170

Figure 4-6 Rescanning storage 171

Note SAN booting, with each host having its own boot LUN 172

Bulleted list vCenter Server storage filters 174

Figure 4-7 Enabling storage filter 175

Figure 4-8 Enabling a software iSCSI initiator 176

Note iSCSI adapter reenabled after boot 177

Figure 4-9 Disabling software iSCSI initiator 177

Note iSCSI ports in the same domain and subnet as adapters 178

Figure 4-10 Selecting the VMkernel port to bind 179

Note Separate network adapter for iSCSI 179

Page 68: VCP6-DCV Official Cert Guide

186 VCP6-DCV Official Cert Guide (Exam #2VO-621)

Key Topic Element Description Pages

Figure 4-11 iSCSI CHAP’s Edit button 181

Figure 4-12 CHAP setup options 182

Note No support for modifying thin provisioning at a storage device

184

Complete the Tables and Lists from MemoryPrint a copy of Appendix B, “Memory Tables” (found on the CD), or at least the section for this chapter, and complete the tables and lists from memory. Appendix C, “Memory Tables Answer Key,” also on the CD, includes completed tables and lists to check your work.

Definitions of Key TermsDefine the following key terms from this chapter and check your answers in the glossary.

Small Computer Systems Interface (SCSI), Fibre Channel (FC), Fibre Chan-nel over Ethernet (FCoE), Internet Small Computer System Interface (iSCSI), Network File System (NFS), Kerberos, Parallel NFS (pNFS), software iSCSI initiator, independent hardware iSCSI initiator, dependent hardware iSCSI initiator, vCenter Server storage filters, Challenge Handshake Authentication Protocol (CHAP)

Answer Review Questions

The answers to these review questions can be found in Appendix A.

1. Which device cannot appear as a LUN?

a. Tape device

b. iSCSI

c. FC

d. NFS

Page 69: VCP6-DCV Official Cert Guide

2. Which of the following statements is not correct?

a. A CD-ROM can be connected to a SCSI bus and appear as a LUN.

b. You do not need to configure networking for a dependent hardware iSCSI initiator.

c. A software iSCSI initiator is a standard 1 GbE or 10 GbE NIC.

d. The ESXi Host does not need a VMkernel port for an independent hardware iSCSI initiator.

3. What TCP port is the default iSCSI port?

a. 3620

b. 3720

c. 3270

d. 3260

4. Which NFS protocols are not supported in vSphere 6.0? (Choose two.)

a. NFSv3

b. NFSv4.0

c. NFSv4.1

d. pNFS

5. Which of the following statements about iSCSI is incorrect?

a. CHAP is a method for authenticating the ESXi Host and a storage de-vice using password authentication.

b. CHAP is a required security feature for iSCSI.

c. With unidirectional CHAP, the ESXi Host does not authenticate the storage device.

d. vSphere supports bidirectional CHAP for software and dependent hard-ware iSCSI adapters only.

Page 70: VCP6-DCV Official Cert Guide
Page 71: VCP6-DCV Official Cert Guide

Index

A

access control (role-based)Administrator roles, 20groups

applying roles to, 16

group lists, 6

No Access roles, 20objects, applying roles to, 16permissions

adding permissions, 7-10

applying permissions, 10-14

changing validation settings, 17-20

explicit permissions, 6

managing permissions, 7-10

modifying permissions, 7-10

propagated permissions, 6

removing permissions, 7-10

vCenter Server integration, 21-23

Read Only roles, 20sample roles, 20-21system roles, 20users

applying roles to, 16

user lists, 6

vCenter Server roles, 14-15vmdir, configuring, 15-16

ACPI (Advanced Configuration and Power Interface), 172, 489

Active DirectoryESXi Hosts

adding to Active Directory domains, 55

security, 35-36

securityadding ESXi Hosts to domains, 55

authentication, 45-48

adding/removingcontent libraries, 618dvPort groups, vDS, 82-86dvUplink groups, vDS, 86-89ESXi Hosts, vDS, 72-77, 80-82Host DRS groups (DRS clusters), 585permissions, role-based access

control, 7-10SSO identity sources, 55virtual machines from resource pools,

308VM/DRS groups (DRS clusters),

585-586VMkernel ports, vDS, 93-97

administration, VDP, 333-334Administration Server (SSO), 41Administrator roles, 20, 40Administrators group (SSO), 53admission control policies (HA

clusters), 575alerts

ESXi Hosts, 480virtual machines, 482vRealize Operations Manager, 479, 482

ALUA (Asymmetrical Logical Unit Access), 208

answer files, host profiles, 542-543APD (All Paths Down), 207, 423-424,

508array thin provisioning, 183

Page 72: VCP6-DCV Official Cert Guide

724 authentication

authenticationActive Directory, 45-48content libraries, 616iSCSI CHAP, 180-182Kerberos authentication

NFS datastore connections, 238

NFSv4.1, 167

smart card authentication, DCUI, 38vCenter Server, 42

Auto Deployarchitecture of, 532components of, 532configuring, 532, 539ESXi Host

deployments, 532-542

upgrades, 437

host profiles, 537-539Image Builder, 533-537installing, 539PowerCLI

cmdlets, 540-541

scripts, 533-534

auto-rollback behavior in vDS, 127-129automation level (DRS clusters),

configuring, 587

B

backup/recoverycompression, 321RPO, 323-324snapshots, 325-327vCenter Server

embedded Linux vCenter Server backups, 279-283

embedded Windows vCenter Server back-ups, 279-281

VDPadministration, 333-334

backup limitations, 334

capabilities of, 322-323

configuring, 328-334

creating backup jobs, 334-335

creating backup storage, 333

Emergency Restore feature, 338-340

installing, 327, 331

sizing guidelines, 324

snapshots, 325

system requirements, 324

virtual machine backup/restore, 335-340

virtual machinesrecovering via vSphere Replication,

345-346

VDP, 335-340

vSphere Replicationconfiguring, 340-341

configuring for virtual machines, 342-345

deploying, 340

deploying VRA, 347

deploying VRS, 347

failback operations, 346

installing, 340

integrating VMCA with, 341

recovering virtual machines, 345-346

upgrading on virtual machines, 345

VRA, 341

VRS appliances, 341

ballooning (memory metric)ESXi Hosts, 457-458vSphere Web Client, 457

baselinesESXi Host upgrades, 267vSphere 6.0 upgrades, 267

bidirectional (mutual) CHAP, 180binding

dynamic binding and vDS, 84Ephemeral and vDS, 85static binding and vDS, 84

block zeroing (VAAI), 230blocking vDS ports, 66, 111-112bus sharing, 236-237

Page 73: VCP6-DCV Official Cert Guide

725clusters

C

CA (Certificate Authority), 39, 50CAAdmins group (SSO), 52capacity, HA clusters, 500-507catalog setting (virtual machines), 627CDB (Command Descriptor Blocks),

SCSI CDB, 167certificates

ESXi Host upgrades, 280vCenter Server

security, 39

upgrades, 280

changing permission validation settings, 17-20

CHAP (Challenge Handshake Authenti-cation Protocol), iSCSI CHAP, 180-182

claim rules, multipathingeffects on, 210-211functions of claim rule elements, 211-212

CLI (Command-Line Interface)ESXCLI, ESXi Host upgrades, 438-439vCLI, 372

cloning vCenter Server roles, 14-15clouds

hybrid clouds, 619vCloud Air

deploying virtual machines, 621

Disaster Recovery Service, 625-627

migrating virtual machines to vCloud Air, 621-622

vCenter Server connections, 623-625

vCloud Connector, 619

verifying VPN connections, 623

virtual machine configuration, 627

VPN connections to on-premise sites, 619-621

clustersDRS clusters

affinity rules, 586-588

automation level configuration, 587

configuring, 507-511

DPM, 498

failover, 516

fault tolerance, 516

HA clusters, 581

Host DRS groups, 585

initial power on, 497

migrating virtual machines via vMotion, 497

resource distribution graphs, 519-522

resource pools, 293, 511

Summary tab, 519-522

troubleshooting, 495-498, 507-511, 516, 519-522

VM/DRS groups, 585-586

VM-Host Affinity/Anti-Affinity rules, 582-584

VM-VM Affinity/Anti-Affinity rules, 584-585

workload balancing, 497-498

HA clusters, 573admission control policies, 575

capacity, 500-507

change HA Admission Control policy, 505

change the default isolation response, 504

configure heartbeat datastores, 502-503

configure management network redundancy, 502

configure redundant heartbeat addresses, 503-504

configuring, 507-511

DPM, 581

DRS clusters, 581

enabling/disabling settings, 576-578

failover, 515

failover/redundancy, 500-507

fault tolerance, 515

FDM, 574

Page 74: VCP6-DCV Official Cert Guide

726 clusters

heartbeat alarm messages, 575

heartbeat datastore configurations, 578

heartbeats and network configurations, 574

modifying, 573

network configuration, 500-507

troubleshooting, 495, 500-504, 507-511, 515

virtual machine monitoring, 579

virtual SAN cluster implementation, 581

VMCP configuration, 580

host profilesattaching to ESXi Host in clusters,

549-551

compliance scanning of ESXi Host in clusters, 552

moving to clusters, 20

remediation of ESXi Host in clusters, 553-555

cmdlets (PowerCLI), 540, 541CNA (Converged Network Adapters),

FCoE, 166cold migration, 19Commands per Second (storage

metrics), 467Community PVLAN (Private VLAN) and

vDS, 117compatibility and vCenter Server

upgrades, 283-284compliance scanning of ESXi Hosts in

clusters, 552compression (memory metric)

decompression, 321ESXi Hosts, 321, 458FastLZ compression library, 321vSphere Web Client, 458

configuringAuto Deploy, 532, 539automation level (DRS clusters), 587configuration parameters setting (virtual

machine configurations), 605

content librariesauthentication, 616

multi-site library configuration, 614-616

download sources for vSphere 6.0 upgrades, 264

DRS clusters, 507-511, 587dvPort group settings, vDS, 90-92ESXi servers, 511HA clusters, 500-511, 580HA heartbeats

datastores, 578

network configurations, 574

LACPdvPort groups, 101-104, 107-109

dvUplink groups, 101-104, 107-109

load balancing, 215networks, 574NIOC, 142-145, 418-420PSC, 48-50resource pools, 301RPO, 323-324SIOC, 249-250, 421-422SP, multipathing, 217SSO policies, 54-55vCenter Server logging options, 439-441VDP, 328-334vDS, 90-92virtual machines

catalog setting, 627

configuration parameters setting, 605

debugging setting, 604

differentiating configuration settings, 603-608

DirectPath I/O, 599-600

disable acceleration setting, 604

enable logging setting, 604

enabling/disabling advanced settings, 611

latency sensitivity setting, 605

name setting, 627

NIOC, 143-145

Page 75: VCP6-DCV Official Cert Guide

727datastores

NUMA, 608-610

security policies, 28

SR-IOV, 600

statistics setting, 604

swapfile location setting, 605

template setting, 627

vCloud Air, 627

vCPU, 602

vGPU, 601

virtual datacenter setting, 627

virtual hardware setting, 627

VMX file settings, 610-611

virtual switches across multiple hosts via host profiles, 544-546

VMCA, 50-51VMCP, 580vmdir, 15-16vMotion, troubleshooting, 511VSAN, 197-200, 203-204vSphere Replication, 340-345

console security (virtual machines), 23consolidating snapshots, 325-327content libraries

adding/removing, 618configuring

authentication, 616

multi-site libraries, 614-616

defining, 612ISO files, 612local content libraries, 612managing, 613OVF files, 612passwords, 612published content libraries, 612-616roles/permissions, 617security, 612storage, 612subscribed content libraries, 612-613, 616synchronization in, 613-614

copy/paste and virtual machines, 26CoS (Cost of Service), NIOC, 140CPU (Central Processing Units)

metricsCPU Co-stop, 463

CPU Entitlement, 463

CPU Ready, 463

CPU Ready Time, 455

CPU Swap Wait, 463

CPU System, 463-465

CPU Wait, 463

troubleshootingcontention issues, 451-452

limits, 452-454

monitoring performance, 450

reservations, 452-454

shares, 452-454

vCPU, virtual machine configurations, 602creating

host profiles, 546-547resource pools, 306-309snapshots, 325-327vCenter Server roles, 14-15vDS, 68-71virtual adapters, vDS, 93-97virtual machines, permissions, 18

CSR (Certificate Signing Requests), 39customizing

host profiles, 542-543, 555resource pools, 301

D

dashboard (vRealize Operations Manager), 478

data compression, 321Datastore Browser, vCenter Server secu-

rity, 39datastores

APD, 508HA heartbeat datastore configurations,

502-503, 578

Page 76: VCP6-DCV Official Cert Guide

728 datastores

NFS datastoresconnecting using Kerberos authentication,

238

mounting/unmounting, 241-242

multiple datastore usage scenarios, 245-246

properties of, 232

PDL, 508permissions, managing, 8-10SRDS, troubleshooting, 414-415VMFS datastores

comparing functionality of new/upgraded datastores, 233

creating, 239-240

deleting, 240

enabling/disabling paths, 244

expanding, 242

extending, 242-243

maintenance mode, 243

multiple datastore usage scenarios, 245

properties of, 232

renaming, 240

unmounting, 240

VVOL creation, 201DCAdmins group (SSO), 52DCUI (Direct Console User Interface)

ESXi Hosts, controlling access, 38-39Lockdown mode (ESXi Hosts), 37Restore Network Settings option, 405Restore Standard Switch option, 405Restore vDS option, 405smart card authentication, 38

debugging setting (virtual machine con-figurations), 604

decompression, 321deleting

resource pools, 306-309snapshots, 325-327vDS, 68-71virtual adapters, vDS, 93-97

virtual machines from resource pools, 308VMFS datastores, 240

dependent hardware iSCSI initiators, 171, 175-178

deployingESXi Hosts, Auto Deploying multiple

ESXi Hosts, 541physical hosts as virtual machines via

vCenter Converter, 563Platform Service Controller

certificates, 280

embedded deployments, 278

external deployments, 278-279

vCenter Serverembedded deployments, 278

external deployments, 278-279

virtual machinespermissions, 18

vCloud Air, 621

VRA, 341, 347VRS, 347VRS appliances, 341vSphere Replication, 340

DES-CBS-MD5 encryption protocol, 238diagnostics

ESXi Hosts, 361-368, 431vCenter Converter, 564vSphere upgrades, 431

directory services, ESXi Host security, 35-36

DirectPath I/O and virtual machines, 599-600

disable acceleration setting (virtual machine configurations), 604

disabling unnecessary services (virtual machine security), 24

Disaster Recovery Service (vCloud Air), 625-627

Disk Aborts performance metric, 455disk groups, 199-200Disk Latency performance metric, 454

Page 77: VCP6-DCV Official Cert Guide

729ESXi Hosts

disk shrinking, 26DMP (Dynamic Multipathing Plug-in),

209DNS (Domain Name System) servers,

VDP installations, 327DoS (Denial-of-Service) attacks, virtual

machine security, 29-30downloading

UMDS, 430vSphere 6.0 upgrades, 264

DPM (Distributed Power Management), 490, 498, 581

DRS (Distributed Resource Scheduler) clusters

adding/removingHost DRS groups, 585

VM/DRS groups, 585-586

affinity rulesenabling/disabling, 586

virtual machine placement, 588

automation level configuration, 587configuring, 507-511DPM, 498failover, 516fault tolerance, 516HA clusters, 581initial power on, 497migrating virtual machines via vMotion,

497resource distribution graphs, 519-522resource pools, 293, 511Summary tab, 519-522troubleshooting, 495

configurations, 507-511

fault tolerance, 516

target/current host load deviation, 519-522

workload balancing, 497-498

VM-Host Affinity/Anti-Affinity rules, 582-584

VM-VM Affinity/Anti-Affinity rules, 584-585

workload balancing, 497-498

DVFS (Dynamic Voltage and Frequency Scaling), 489

dvPort groupsNIOC, 152-153vDS

adding/removing dvPort groups, 82-86

configuring blocking policies, 111-112

configuring dvPort group settings, 90-92

configuring LACP, 101-104, 107-109

security policies/settings, 109-111

VLAN, 86dvUplink groups, vDS

dvUplink groups, adding/removing, 86-89

LACP configuration, 101-104, 107-109

dynamic binding and vDS, 84Dynamic Queue Depth Throttling, 252

E

editinghost profiles, 546-547, 555SSO identity sources, 55vCenter Server roles, 14-15

Emergency Restore feature (VDP), 338-340

enable logging setting (virtual machine configurations), 604

encryptionDES-CBC-MD5 encryption protocol, 238Kerberos encryption and NSF datastore

connections, 238error-handling during conversion via

vCenter Converter, 562-563ESXCLI command, 375-376

ESXi Host upgrades, 438-439thumbprints, 373virtual machines, troubleshooting, 385

ESXi Hostsadding to Active Directory domains, 55alerts, 480APD, 207, 423

Page 78: VCP6-DCV Official Cert Guide

730 ESXi Hosts

array thin provisioning, 183Auto Deploying

configuring Auto Deploy, 539

host profiles, 537-539

Image Builder, 533-537

installing Auto Deploy, 539

multiple ESXi Hosts, 541

overview of, 532

PowerCLI cmdlets, 540-541

PowerCLI scripts, 533-534

usage scenario, 542

ballooning, 457-458booting from

FC, 172

FCoE, 173

iSCSI, 172

iSCSI LUN, 175

claim rules and multipathingeffects of, 210-211

functions of, 211-212

clustersattaching host profiles to ESXi Hosts in

clusters, 549-551

compliance scanning of ESXi Hosts in clusters, 552

remediation of ESXi Hosts in clusters, 553-555

compression, 321, 458diagnostics, 361-368disk groups, 199-200driver types, 212ESXCLI command, 375-376

ESXi Host upgrades, 438-439

thumbprints, 373

troubleshooting virtual machines, 385

extensions, 269FC zoning, 183firewalls, 31-33group lists, 7guest OS paging, 459host profiles, 537-539

answer files, 542-543

attaching to ESXi Hosts in clusters, 549-551

compliance scanning of ESXi Hosts in clusters, 552

creating, 546-547

customizing, 542-543, 555

editing, 546-547, 555

importing/exporting, 548-549

modifying, 555

PSP, 543-544

remediation of ESXi Hosts in clusters, 553-555

removing, 546-547

SATP, 543-544

virtual switch configurations across mul-tiple hosts, 544-546

iSCSI port binding, 178-179logs, 369-371LUN, 164

discovering new storage LUN, 171-172

FC zoning, 183

iSCSI LUN bootups, 175

paths, 169

thin provisioning, 183-184

VMDK, 165

VVOL, 194

management agents, 359-361monitoring

host hardware health, 368

system health, 368

multipathingclaim rules, 210-212

DMP, 209

Fixed PSP, 217

MRU PSP, 216

Round Robin PSP, 216

SP, 217

NFS, 167creating NFS shares, 173

Page 79: VCP6-DCV Official Cert Guide

731ESXi Hosts

datastore connections using Kerberos authentication, 238

locking, 236

mounting/unmounting datastores, 241-242

overview graphs, 483patches, 269PDL, 208permissions, 6-10power management policies, 489RDM filters, 174resource pools, 293, 306-307security, 30

Active Directory, 35-36

adding ESXi Hosts to Active Directory domains, 55

adding ESXi Hosts to directory services, 35-36

applying permissions via host profiles, 36-37

controlling host access, 38-39

default account access, 34-35

firewalls, 31-33

Lockdown mode, 37

passwords, 34-35

SIOC, 247SP, configuring for multipathing, 217SR-IOV, 600stability, determining, 361-368storage

naming conventions, 168-169

troubleshooting, 407-410

storage adapters, 163-165swapping, 459Syslog Collector, troubleshooting, 381-383thin provisioning, 184thumbprints, 372TPS, 456troubleshooting, 426

APD state, 423

determining stability, 361-368

ESXCLI command, 373-376

gathering diagnostics, 361-368

logs, 369-371

monitoring host hardware health, 368

monitoring management agent status, 359-361

monitoring system health, 368

performance, 450

Syslog Collector, 381-383

thumbprints, 372

upgradesbaselines, 267

certificates, 280

ESXCLI, 438-439

ESXi Installer, 434

importing images, 265-266

multiple upgrades, 274-276

remediating objects, 269-270

requirements, 265

scanning vSphere objects, 269

scripted upgrades, 435-437

staging patches/extensions, 269

troubleshooting, 430-431, 434-439

upgrading vDS, 270

upgrading VMware Tools, 271-272

VMware Update Manager, 434

vSphere Auto Deploy, 437

VUM and ESXi Host upgrades, 273

USB devices, 597-598user lists, 6VAAI, 229-230vDS, adding/removing ESXi Hosts,

72-77, 80-82vFlash, 302, 305virtual disk thin provisioning, 184virtual machines

compatibility options table, 25-26

DirectPath I/O, 599

swapping, 459

VMCI, 29

Page 80: VCP6-DCV Official Cert Guide

732 ESXiHosts

VMFSdatastore paths, 244

filters, 174

multiple datastore usage scenarios, 245

VSAN, 197-200ESXi Installer, ESXi Host upgrades, 434ESXi servers

configuring, 511DRS cluster target/current host load

deviation, 522upgrading, 518vMotion migrations, 513

ESXTOPreplay mode, 363-364troubleshooting performance, 451-452,

462, 467-468, 471-473Ethernet

FCoE, 166, 173iSCSI, 166-167

CHAP, 180-182

dependent hardware iSCSI initiators, 171, 175-178

ESXi boot device, 172

hardware/software initiator require-ments, 170-171

iBFT, 175

independent hardware iSCSI initiators, 171, 178

LUN boots, 175

LUN paths, 169

port binding, 178-179

software iSCSI initiators, 171, 176-177

EVC (Enhanced vMotion Compatibility), troubleshooting performance, 473-477

eventsvCenter Server, 484-489virtual machine events, 486

exampreparing for, 631-634strategies for taking, 634-636

expandable reservations and resource pools, 295

explicit permissions, role-based access control, 6

exportinggroup lists, 6SSO group lists, 7SSO user lists, 7user lists, 6

Extended Copy command (SCSI). See VAAI, XCOPY command

extensions, ESXi Hosts, 269

F

failback operations, vSphere Replication, 346

failoverDRS clusters, 516HA clusters, 500-507, 515multipathing, 218troubleshooting, 514-518vDS, 113

FastLZ compression library, 321fault tolerance

DRS clusters, 516HA clusters, 515troubleshooting, 514-518

FC (Fibre Channel), 166ESXi boot device, 172LUN, 164-165, 169storage, troubleshooting, 424zoning, 183

FCoE (Fibre Channel over Ethernet), 166, 173

FDM (Fault Domain Manager), 574file locking and NFSv3, 167firewalls, ESXi Hosts, 31-33Fixed PSP (Path Selection Policy), 217folder permissions, 6, 16Forged Transmits (security policies/

settings), 30, 110

Page 81: VCP6-DCV Official Cert Guide

733host profiles

FT (Fault Tolerance), troubleshooting network latency, 389-391

G

global permissions, 14GPU (Graphics Processing Units), virtual

machines and vGPU, 601groups

applying roles to, 16group lists, 6-7

Guest Latency (storage metrics), 466guest OS

paging, 458-459quiescing, 342

H

HA (High Availability) clusters, 573admission control policies, 575capacity, 500-507changing

default isolation response, 504

HA Admission Control policy, 505

configuringheartbeat datastores, 502-503, 578

management network redundancy, 502

redundant heartbeat addresses, 503-504

troubleshooting, 507-511

VMCP, 580

DPM, 581DRS clusters, 581enabling/disabling settings, 576-578failover, 500-507, 515fault tolerance, 515FDM, 574heartbeats

alarm messages, 575

datastore configurations, 502-503, 578

network configurations, 574

redundant heartbeat addresses, 503-504

modifying, 573

network configuration, 500-507troubleshooting, 495

capacity, 500-507

configurations, 507-511

failover, 515

failover/redundancy, 500-504

fault tolerance, 515

network configuration, 500-507

virtual machine monitoring, 579virtual SAN cluster implementation, 581VMCP, 580

hardware iSCSI initiators, 171, 175-178HBA (Host Bust Adapters), FCoE, 166HCL (Hardware Compatibility Lists),

209heartbeats (HA clusters)

alarm messages, 575datastore configurations, 502-503, 578network configurations, 574redundant heartbeat addresses, 503-504

Horizon View, 21-22Host DRS groups (DRS clusters),

adding/removing, 585host profiles

answer files, 542-543creating, 546-547customizing, 542-543, 555editing, 546-547, 555ESXi Hosts

attaching profiles to ESXi Hosts in clus-ters, 549-551

Auto Deploy and ESXi Hosts, 537-539

compliance scanning of ESXi Hosts in clusters, 552

remediation of ESXi Hosts in clusters, 553-555

security, 36-37

importing/exporting, 548-549modifying, 555moving to clusters, 20PSP, 543-544

Page 82: VCP6-DCV Official Cert Guide

734 host profiles

removing, 546-547SATP, 543-544virtual switch configurations across mul-

tiple hosts, 544-546Host Rescan filters, 174hybrid clouds, 619hyperthreading virtual machine configu-

ration for vCPU, 602

I

iBFT (iSCSI Boot Firmware Table), 172, 175

IDE/ATA (Integrated Drive Electron-ics/AT Attachments), virtual machine storage, 164

Identity Management Service, 41Image Builder

Auto Deploy, 533-537Image Profile, 534Software Depot, 534VIB, 533

importing/exporting host profiles, 548-549

independent hardware iSCSI initiators, 171, 178

installingAuto Deploy, 539ESXI Hosts, Auto Deploying multiple

ESXi Hosts, 542guest OS on virtual machines, 19PSC, 387-388SSL certificates, 342SSO, multi-site SSO installations, 42-45vCenter Converter, 556-557VDP, 327, 331VMware Tools, 388-389vSphere Replication, 340

integratingvCenter Server, 21-23VMCA with vSphere Replication, 341vSphere Replication with VMCA, 341

IPsec (Internet Protocol Security), vCloud Air connections to on-premise sites, 619-621

iSCSI (Internet Small Computer System Interface), 166-167

CHAP, 180-182dependent hardware iSCSI initiators, 171,

175-178ESXi boot device, 172hardware/software initiator requirements,

170-171iBFT, 172, 175independent hardware iSCSI initiators,

171, 178LUN, 164-165, 169, 175port binding, 178-179software iSCSI initiators, 171, 176-177storage, troubleshooting, 406-407, 424

ISO files, content libraries, 612Isolated PVLAN (Private VLAN) and

vDS, 118

J

jumbo frames, 123-127

K

Kerberos authenticationNFS datastore connections, 238NFSv4.1, 167

Kernel Latency (storage metrics), 466

L

LACP (Link Aggregate Control Protocol)

configuringdvPort groups, 101-104, 107-109

dvUplink groups, 101-104, 107-109

troubleshooting, 425LAG ports and vDS, 102-103, 106-109latency sensitivity setting (virtual

machine configurations), 605

Page 83: VCP6-DCV Official Cert Guide

735memory

LicenseService.Administrators group (SSO), 53

limitsCPU/memory, 452-454resource pools, 294

Linux vCenter Serverembedded backups, 279pre-upgrade updates, 280-281vCSA upgrades, 281-283

listsgroup lists, 6-7user lists, 6-7

load balancing, 207configuring, 215differentiating options, 216load-based teaming and vDS, 66, 114vDS, 113

load-based teaming and vDS, 66, 114local content libraries, 612Lockdown mode, ESXi Host security, 37locking

files and NFSv3, 167hardware-assisted locking (VAAI), 230NFS, 236virtual machines, multi-writer locking,

237-238lockouts, SSO, 55logins, configuring vCenter Server log-

ging options, 439-441logs

ESXi Hosts, 369-371log browser, 371log bundles, 366-367, 432-433vCenter Server, 369-371virtual machines, 26

LUN (Logical Unit Numbers), 164-165active optimized/active non-optimized

port groups and multipathing, 208FC zoning, 183iSCSI LUN bootups, 175paths, 169

RDM, 174, 233-235Same Host and Transports filters, 174SP, configuring for multipathing, 217storage, 171-172thin provisioning, 183-184VMDK, 165VMFS

filters, 174

multiple datastore usage scenarios, 245

VVOL, 194

M

MAC address security, 30, 110maintaining vCenter Server databases,

357-359maintenance mode (VMFS datastores),

243managing

content libraries, 613permissions

datastores, 8-10

ESXi Hosts, 8-10

role-based access control, 7-10

virtual machines, 8-10

vDS, 67memory

Memory Consumed (Memory Usage), 461Memory Overhead, 460Memory Reservation, 461Memory Swapped performance metric,

455metrics, 462

ballooning, 457

compression, 458

swapping, 458-461

TPS, 455-456

NUMA, 462reservations, virtual machines, 462troubleshooting, 462

contention issues, 451-452

limits, 452-454

Page 84: VCP6-DCV Official Cert Guide

736 memory

monitoring performance, 450

reservations, 452-454

shares, 452-454

virtual NUMA, 462metadata (VMFS), troubleshooting,

428-429migrating

cold migration, 19Memory Swapped performance metric,

455storage vMotion, 512-514virtual machines

old migration, 19

Storage vMotion, 20, 336

vCloud Air, 621-622

vDS, 98-100

vDS, 67

vMotion, 19, 497

VMkernal virtual network adapters, 405vMotion, 130, 512-514

mirroring vDS ports, 67MOB (Managed Object Browser), con-

trolling access toESXi Hosts, 38-39vCenter Server, 40

modifyingHA clusters, 573host profiles, 555permissions, role-based access control,

7-10resources during conversion via vCenter

Converter, 561-562monitoring

CPU, 450ESXi Hosts

host hardware health, 368

management agent status, 359-361

system health, 368

memory, 450NIOC, 151

performanceESXTOP, 451-452, 462, 467-468,

471-473

EVC, 473-477

RESXTOP, 473

VMware PerfMon DLL, 450

vRealize Operations Manager, 450

vSphere Client, 450

vSphere Web Client, 451-452

Windows Performance Monitor, 450

SIOC, 250-251SRDS, 414-417vCenter Server service status, 354-357vDS port state, 67virtual machines and HA clusters, 579vSphere

network resources, 399, 402-404

storage resources, 399, 402-404

mounting NFS datastores, 241-242moving

hosts to clusters, 20virtual machines to resource pools, 19

MPIT (Multiple Points In Time), vSphere Replication configuration on virtual machines, 343

MPP (Multipathing Plug-in), 209, 216, 244

MRU (Most Recently Used) PSP, 216multipathing

active optimized/active non-optimized port groups, 208

ALUA, 208APD, 207claim rules

effects of, 210-211

functions of, 211-212

DMP, 209failover events, 218load balancing, 215-216MPP, VMFS datastore paths, 244MRU PSP, 216

Page 85: VCP6-DCV Official Cert Guide

737networks

NFS, 167, 235optimizing paths, 208PDL, 208PSA

MPP, 209, 216

NMP, 210

PSP, 210

SATP, 210

PSP, 213-217SATP, 215SP, 217

N

namingname setting (virtual machines), 627VMFS datastores, 240

NAS (Network Access Server)iSCSI, 166-167

CHAP, 180-182

dependent hardware iSCSI initiators, 171, 175-178

ESXi boot device, 172

hardware/software initiator require-ments, 170-171

independent hardware iSCSI initiators, 171, 178

LUN boots, 175

LUN paths, 169

port binding, 178-179

software iSCSI initiators, 171, 176-177

LUN, 164-165discovering new storage LUN, 171-172

FC zoning, 183

iSCSI LUN bootups, 175

paths, 169

thin provisioning, 183-184

VMDK, 165

VVOL, 194

NFS, 167, 173storage adapters

displaying, 164

identifying, 163

LUN, 164-165, 169-172

storage devices for adapters, 164-165

storage naming conventions, 168, 169thin provisioning, 183-184vCenter Server storage filters, 173-175

NCIDIA VIB, virtual machines and vGPU, 601

NetFlow and vDS, 67networks

APD state, troubleshooting, 423-424configuring, 574HA heartbeats, 574HA cluster network configuration, 500-

507latency (FT), troubleshooting, 389-391metrics

Network Packets Dropped performance metric, 455

Packet Receive Errors/Packet Transmit Errors, 465

Transmit Packets Dropped/Receive Pack-ets Dropped, 465

Transmit/Receive Rates, 465

NIOC, 135-136configuring, 142-145, 418-420

CoS, 140

defining, 138

dvPort groups, 152-153

monitoring, 151

port groups, 140

resource pools, 141-145, 151

system traffic, 146, 151

troubleshooting, 418-420

upgrading, 138-143

vDS, 67, 70, 92, 138-143

virtual machines, 143-145, 152-153

physical network adapters, troubleshoot-ing, 427-428

Page 86: VCP6-DCV Official Cert Guide

738 networks

Restore Network Settings option (DCUI), 405

Restore vDS option (DCUI), 405rollback (auto) and vDS, 127-129SIOC, 421-422vDS, 61

adding/removing dvPort groups, 82-86

adding/removing dvUplink groups, 86-89

adding/removing ESXi Hosts, 72-77, 80-82

adding/removing VMkernel ports, 93-97

auto-rollback behavior, 127-129

blocking policies for dvPort groups, 111-112

capabilities of, 65-66

configuring dvPort group settings, 90-92

configuring LACP, 101-104, 107-109

creating/deleting, 68-71

creating/deleting virtual adapters, 93-97

datacenter-level management, 67

dynamic binding, 84

Ephemeral, 85

failover policies, 113

jumbo frames, 123-127

LAG ports, 102-103, 106-109

load balancing, 113

load-based teaming, 66, 114

managing, 67

migrating virtual machines, 98-100

NetFlow, 67

network vMotion, 67

NIOC, 67, 70, 92

port blocking, 66, 111-112

port mirroring, 67

port policy settings, 67

port state monitoring, 67

PVLAN, 66, 114-119

security policies/settings, 109-111

static binding, 84

TCP segmentation offload support, 122-123

traffic shaping, 66, 119-121

vCenter Servers and long-distance vMotion support, 129-130

virtual machine migration, 67

VLAN, 114-119, 127

vMotion support (long-distance), 129-130

virtual machines, 410-414VLAN, troubleshooting, 426VPN, 619-623vSphere

monitoring, 399, 402-404

NIOC, 418-420

SIOC, 421-422

troubleshooting, 399, 402-407, 410, 425-426

verifying configurations, 404-407, 410

vSScapabilities of, 65-66

jumbo frames, 123-127

NFS (Network File System)datastores

connecting using Kerberos authentication, 167, 238

mounting/unmounting, 241-242

multiple datastore usage scenarios, 245-246

properties of, 232

locking, 236multipathing, 167, 235NFSv3, 231

locking, 167, 236

multipathing, 235

security, 236

session trunking, 235

NFSv4.1, 231Kerberos authentication, 167, 238

locking, 236

multipathing, 235

Page 87: VCP6-DCV Official Cert Guide

739performance

security, 236

session trunking, 235

pNFS, 167security, 236session trunking, 167, 235shares, creating, 173

NIOC (Network I/O Control), 135configuring, 142-145, 418-420CoS, 140defining, 138dvPort groups, 152-153monitoring, 151port groups, 140resource pools, 141-145, 151system traffic, 146, 151troubleshooting, 418-420upgrading, 138-143vDS, 67, 70, 92, 138-143virtual machines, 143-145, 152-153

NMP (Native Multipathing Plug-in), 210No Access permission, 11-12No Access roles, 20NTP (Network Time Protocol), VDP

installation, 327NUMA (Non-Uniform Memory Access),

462, 608-610

O

objects, applying roles to, 16optimized paths, 208OS (guest), installing on virtual

machines, 19overriding permissions, 11-12overview graphs, 483-484OVF (Open Virtualization Format) files,

content libraries, 612

P

P2V (Physical-to-Virtual) migrations and VMware Converter, 556

Packet Receive Errors/Packet Transmit Errors (network metrics), 465

partitions, resizing during conversion via vCenter Converter, 564

passwordscontent libraries, 612ESXi Hosts, 34-35SSO, 54UPN, 47

patches, ESXi Hosts, 269path failover, 207PCC (Processor Clocking Control), 490PCLMULQDQ instruction set, 477PDL (Permanent Device Loss), 208, 409,

423, 508PE (Protocol Endpoints), VVOL, 206performance

CPUcontention issues, 451-452

limits, 452-454

metrics, 463-465

monitoring, 450

reservations, 452-454

shares, 452-454

memorycontention issues, 451-452

metrics, 455-462

monitoring, 450

reservations, 452-454

shares, 452-454

metrics, 465-467CPU Ready Time, 455

Disk Aborts, 455

Disk Latency, 454

Memory Swapped, 455

Network Packets Dropped, 455

monitoringESXTOP, 451-452, 462, 467-468,

471-473

EVC, 473-477

Page 88: VCP6-DCV Official Cert Guide

740 performance

RESXTOP, 473

VMware PerfMon DLL, 450

vRealize Operations Manager, 450

vSphere Client, 450

vSphere Web Client, 451-452

Windows Performance Monitor, 450

networks, 465overview graphs, 483-484performance counters (VMware), 27power management policies, 489-490storage, 466-467troubleshooting

CPU, 450-454

ESXi Hosts, 450

ESXTOP, 451-452, 462, 467-468, 471-473

EVC, 473-477

memory, 450-454

overview graphs, 483-484

power management policies, 489-490

RESXTOP, 473

VMware PerfMon DLL, 450

vRealize Operations Manager, 450, 477-479, 482-483

vSphere Client, 450

vSphere Web Client, 451-452

Windows Performance Monitor, 450

virtual machines, 477-479, 482-483vSphere

CPU contention issues, 451-452

CPU limits, 452-454

CPU metrics, 463-465

CPU monitoring, 450

CPU reservations, 452-454

CPU shares, 452-454

ESXTOP, 467-468, 471-473

EVC, 473-477

memory contention issues, 451-452

memory limits, 452-454

memory metrics, 455-462

memory monitoring, 450

memory reservations, 452-454

memory shares, 452-454

metrics, 454-455

network metrics, 465

overview graphs, 483-484

power management policies, 489-490

RESXTOP, 473

storage metrics, 466-467

vRealize Operations Manager, 477-479, 482-483

permissionsadding, role-based access control, 7-10applying, role-based access control, 10-14assigning permissions to

folders, 16

resource pools, 16

changing validation settings, 17-20content libraries, 617datastores, 8-10ESXi Hosts, 6

managing permissions, 8-10

moving to clusters, 20

security, 36-37

explicit permissions, role-based access control, 6

folders, 6, 16global permissions, 14managing

datastores, 8-10

role-based access control, 7-10

modifying, role-based access control, 7-10No Access permission, 11-12overriding, 11-12propagated permissions, role-based access

control, 6removing, role-based access control, 7-10required permissions for common tasks

table, 18-20resource pools, 16role-based access control, 6-14

Page 89: VCP6-DCV Official Cert Guide

741PSC (Platform Services Controller)

vCenter Server, 6-14, 21-23virtual machines, 6-10, 18-20vSphere Client, 6-10vSphere Inventory Hierarchy, 10-13

Physical Device Latency (storage metrics), 466

physical hosts, deploying as virtual machines via vCenter Converter, 563

physical network adapters, troubleshoot-ing, 427-428

physical (passthrough) mode (RDM), 233-235

physical workloads, converting via vCen-ter Converter, 557-560

Platform Service Controllercertificates, 280components of, 277embedded deployments, 278external deployments, 278-279vCenter Server upgrades, 277

pNFS (parallel NFS), 167ports

dvPort groupsadding/removing from vDS, 82-86

blocking policies for vDS, 111-112

configuring LACP for vDS, 101-104, 107-109

configuring settings for vDS, 90-92

security policies/settings for vDS, 109-111

VLAN, 86

ESXi Host firewalls, 33iSCSI port binding, 178-179LAG ports and vDS, 102-103, 106-109port groups

active optimized/active non-optimized port groups and multipathing, 208

NIOC, 140

troubleshooting, 426-427

vCenter Server ports, list of, 380-381vDS ports

adding/removing dvPort groups, 82-86

adding/removing VMkernel ports, 93-97

blocking, 66, 111-112

blocking policies for dvPort groups, 111-112

configuring dvPort group settings, 90-92

configuring general settings, 90-92

configuring LACP for dvPort groups, 101-104, 107-109

dynamic binding, 84

editing number of ports, 92

Ephemeral, 85

mirroring, 67

per-port policy settings, 67

security policies/settings for dvPort groups, 109-111

state monitoring, 67

static binding, 84

VMkernel ports, adding/removing from vDS, 93-97

PostgresSQL scripts, vCenter Server maintenance, 359

PowerCLIcmdlets, 540, 541scripts and Auto Deploy, 533-534

power management policies, 489-490preparing for the exam, 631-634Promiscuous mode (security policies/

settings), 30, 110Promiscuous PVLAN (Private VLAN)

and vDS, 117propagated permissions, role-based

access control, 6PSA (Pluggable Storage Architectures),

209-210, 216PSC (Platform Services Controller),

40-41configuring, 48-50installing, 387-388security, 48-50troubleshooting, 386-388, 431vCenter Servers, 42-44, 50vSphere upgrades, 431

Page 90: VCP6-DCV Official Cert Guide

742 PSC (Platform Services Controller)

PSP (Path Selection Policies), 210changing, 213-216Fixed PSP, 217host profiles, 543-544MRU PSP, 216Round Robin PSP, 216

published content libraries, 612-616PVLAN (Private VLAN)

Community PVLAN, 117Isolated PVLAN, 118Promiscuous PVLAN, 117troubleshooting connectivity, 422vDS, 66, 114-119

Q

Queue Latency (storage metrics), 466quiescing

guest OS quiescing, 342support for, 343VSS quiescing, 342

R

RDM (Raw Device Maps)filters, 174physical (passthrough) mode, 233-235virtual machines, multi-writer locking,

237virtual mode, 234-235WSFC, 237

Read Only roles, 20Receive Packets Dropped/Transmit

Packets Dropped (network metrics), 465

Receive/Transmit Rates (network met-rics), 465

recovery/backupcompression, 321RPO, 323-324snapshots, 325-327vCloud Air Disaster Recovery Service,

625-627

VDPadministration, 333-334

backup limitations, 334

capabilities of, 322-323

configuring, 328-334

creating backup jobs, 334-335

creating backup storage, 333

Emergency Restore feature, 338-340

installing, 327, 331

sizing guidelines, 324

snapshots, 325

system requirements, 324

virtual machine backup/restore, 335-340

virtual machinesrecovering via vSphere Replication,

345-346

VDP, 335-340

vSphere Replicationconfiguring, 340-345

deploying, 340, 347

failback operations, 346

installing, 340

integrating VMCA with, 341

recovering virtual machines, 345-346

upgrading on virtual machines, 345

VRA, 341

VRS appliances, 341

redundancy, HA clusters, 500-507remediating

ESXi Hosts in clusters, 553-555objects in ESXi Hosts, 269-270

removingcontent libraries, 618dvPort groups, 82-86dvUplink groups, 86-89ESXi Hosts, 72-77, 80-82Host DRS groups (DRS clusters), 585host profiles, 546-547permissions, role-based access control,

7-10

Page 91: VCP6-DCV Official Cert Guide

743SAML (Security Assertion Markup Language) tokens,

resource pools, 306-309virtual machines from resource pools, 308VM/DRS groups (DRS clusters), 585-586VMkernel ports, 93-97

renaming VMFS datastores, 240reservations

CPU/memory, 452-454resource pools, 294-295virtual machines, 462

resizing partitions during conversion via vCenter Converter, 564

resource distribution graphs, DRS clus-ters, 519-522

resource maps (vMotion), 523-524resource pools, 289

configuring, 301creating/removing, 306-307customizing, 301DRS clusters, 293, 511ESXi Hosts, 293evenly distributed pools, 299expandable reservations, 295hierarchical structures of, 296-297,

311-312limits, 294NIOC, 141-145, 151permissions, 16pools with default values, 298reservations, 294shares, 293-294uneven pools, 299usage scenarios, 311-312vApps, 301vFlash

architecture of, 301, 304-305

creating/removing resource pools, 309

vFRC, 301, 304-305, 309-310

VMDK, 309

virtual machines, 300, 308Restore Network Settings option

(DCUI), 405

Restore Standard Switch option (DCUI), 405

Restore vDS option (DCUI), 405RESXTOP, troubleshooting

performance, 473role-based access control

Administrator roles, 20groups

applying roles to, 16

group lists, 6

No Access roles, 20objects, applying roles to, 16permissions

adding, 7-10

applying, 10-14

changing validation settings, 17-20

explicit permissions, 6

managing permissions, 7-10

modifying permissions, 7-10

propagated permissions, 6

removing permissions, 7-10

vCenter Server integration, 21-23

Read Only roles, 20sample roles, 20-21system roles, 20users

applying roles to, 16

user lists, 6

vCenter Server roles, 14, 15vmdir, 15-16

roles/permissions, content libraries, 617rollback (auto) and vDS, 127-129rollup jobs, vCenter Server, 358Round Robin PSP, 216RPO (Recovery Point Objective),

323-324

S

Same Host and Transports filters, 174SAML (Security Assertion Markup

Language) tokens, 41

Page 92: VCP6-DCV Official Cert Guide

744 SAN (Storage Area Networks)

SAN (Storage Area Networks)FC, 166

ESXi boot device, 172

zoning, 183

FCoE, 166, 173iSCSI, 166-167

CHAP, 180-182

dependent hardware iSCSI initiators, 171, 175-178

ESXi boot device, 172

hardware/software initiator requirements, 170-171

iBFT, 175

independent hardware iSCSI initiators, 171, 178

LUN boots, 175

LUN paths, 169

port binding, 178-179

software iSCSI initiators, 171, 176-177

LUN, 164discovering new storage LUN,

171-172

FC zoning, 183

iSCSI LUN bootups, 175

paths, 169

thin provisioning, 183-184

VMDK, 165

VVOL, 194

NFS, 167, 173storage adapters

displaying, 164

identifying, 163

LUN, 164-165, 169-172

storage devices for adapters, 164-165

storage naming conventions, 168-169thin provisioning, 183-184vCenter Server storage filters, 173-175VSAN, 193-194

configuring, 197-200

disk groups, 199-200

failure domains, 197, 203-204

HA clusters and VSAN implementation, 581

SP, 195

virtual machines, 207

VSAN Observer, 204-205

SATP (Storage Array Type Plug-ins), 210

changing, 215host profiles, 543-544

scripted upgrades, ESXi Hosts, 435-437

SCSI (Small Computer System Interface) protocol

bus sharing, 236-237CDB, 167Extended Copy Command. See VAAI,

XCOPY commandLUN, 164-165, 169

securityActive Directory

adding ESXi Hosts to domains, 55

authentication, 45-48

authenticationActive Directory, 45-48

vCenter Server, 42

content libraries, 612DCUI, smart card authentication, 38DES-CBC-MD5 encryption protocol, 238ESXi Hosts

Active Directory, 35-36

adding ESXi Hosts to directory services, 35-36

adding to Active Directory domains, 55

applying permissions via host profiles, 36-37

controlling host access, 38-39

default account access, 34-35

firewall, 31-33

Lockdown mode, 37

passwords, 34-35

Page 93: VCP6-DCV Official Cert Guide

745SIOC (Storage I/O Control)

Forged Transmits, 30, 110IPsec, vCloud Air connections to on-

premise sites, 619-621Kerberos encryption and NSF datastore

connections, 238MAC addresses, 30, 110NFS, 236passwords

ESXi Hosts, 34-35

UPN, 47

Promiscuous mode, 30, 110PSC, 48-50role-based access control

adding permissions, 7-10

Administrator roles, 20

applying permissions, 10-14

applying roles to groups, 16

applying roles to objects, 16

applying roles to users, 16

changing permission validation settings, 17-20

explicit permissions, 6

group lists, 6

managing permissions, 7-10

modifying permissions, 7-10

No Access roles, 20

propagated permissions, 6

Read Only roles, 20

removing permissions, 7-10

sample roles, 20-21

system roles, 20

user lists, 6

vCenter Server integration, 21-23

vCenter Server roles, 14-15

vmdir, 15-16

SSOadding/removing SSO identity sources,

55

Administration Server, 41

architecture of, 41

configuring policies, 54-55

editing SSO identity sources, 55

enabling/disabling SSO users, 51-52

Identity Management Service, 41

lockouts, 55

multi-site SSO installations, 42-45, 53-54

passwords, 54

STS, 41

tokens, 55

vmdir service, 41

vCenter Server, 39-42vDS policies/settings, 109-111virtual machines

best practices, 23

communications, 29

consoles, 23

data access, 27

device connections, 29

disabling unnecessary services, 24

DoS attacks, 29-30

network security policies, 29-30

policies, 28

resource usage, 23

templates, 23

VMware tools installation, 24-27

VMCA, 50-51session trunking and NFS, 167, 235shares

CPU/memory, 452-454resource pools, 293-294

SIOC (Storage I/O Control)benefits of, 246configuring, 249-250, 421-422Dynamic Queue Depth Throttling

versus, 252enabling/disabling, 247-248features of, 252I/O contention environments, 253monitoring, 250-251

Page 94: VCP6-DCV Official Cert Guide

746 SIOC (Storage I/O Control)

troubleshooting, 421-422usage cases, 252-253

sizing partitions during conversion via vCenter Converter, 564

smart card authentication, DCUI, 38snapshots, 18, 325-327Software Depot, 534software iSCSI initiators, 171, 176-177SolutionUsers group (SSO), 52sorting

group lists, 6user lists, 6

SP (Storage Providers)multipathing SP, configuring, 217VASA, 194-196, 201-202, 206VSAN, 195VVOL, 194-196, 201-202, 206, 217

SPN (Service Principal Name), 47SRDS (Storage Distrubted Resource

Scheduler), 414-417SR-IOV (Single Root I/O Virtualization)

and virtual machines, 600SSH (Secure Shell)

ESXi Hosts, controlling access, 38-39login at vCenter Server node, 378

SSL certificates, 342SSO (Single Sign-On)

adding/removing SSO identity sources, 55Administration Server, 41Administrators group, 53architecture of, 41CAAdmins group, 52configuring SSO policies, 54-55DCAdmins group, 52editing SSO identity sources, 55enabling/disabling SSO users, 51-52group lists, exporting, 7identity Management Service, 41LicenseService.Administrators group, 53lockouts, 55multi-site SSO installations, 42-45, 53-54

passwords, 54security

adding/removing SSO identity sources, 55

configuring policies, 54-55

editing SSO identity sources, 55

enabling/disabling SSO users, 51-52

lockouts, 55

multi-site SSO installations, 42-45, 53-54

passwords, 54

tokens, 55

SolutionUsers group, 52STS, 41SystemConfiguration.Administrators

group, 53SystemConfiguration.BashShellAdminis-

trators group, 52tokens, 55troubleshooting, 378-380user accounts

exporting user lists, 7

installing VDP, 327

Users group, 52

vmdir, 15-16, 41static binding and vDS, 84statistics setting (virtual machine

configurations), 604storage

APD state, troubleshooting, 423-424content libraries, 612ESXi Hosts, troubleshooting storage,

407-410FC, 166

ESXi boot device, 172

zoning, 183

FCoE, 166, 173Fibre Channel storage, 424iSCSI, 166,-167

CHAP, 180-182

dependent hardware iSCSI initiators, 171, 175-178

Page 95: VCP6-DCV Official Cert Guide

747storage

ESXi boot device, 172

hardware/software initiator require-ments, 170-171

iBFT, 175

independent hardware iSCSI initiators, 171, 178

LUN boots, 175

LUN paths, 169

port binding, 178-179

software iSCSI initiators, 171, 176-177

storage, 406-407, 424

load balancing, 215-216LUN

discovering new storage LUN, 171-172

FC zoning, 183

iSCSI LUN bootups, 175

paths, 169

RDM, 233-235

RDM filters, 174

Same Host and Transports filters, 174

SP, 217

thin provisioning, 183-184

VMDK, 165

VMFS, 245

VMFS filters, 174

VVOL, 194

metricsGuest Latency, 466

Kernel Latency, 466

Physical Device Latency, 466-467

Queue Latency, 466

multipathingactive optimized/active non-optimized

port groups, 208

ALUA, 208

APD, 207

claim rules, 210-212

DMP, 209

failover events, 218

load balancing, 215-216

MPP, 244

NFS, 235

optimizing paths, 208

PDL, 208

PSA, 209-210, 216

PSP, 213-217

SATP, 215

SP, 217

VMFS datastores, 244

naming conventions, 168-169NAS, 163

iSCSI, 166-172, 175-182

NFS, 167, 173

storage adapters, 163-165

storage naming conventions, 168-169

thin provisioning, 183-184

vCenter Server storage filters, 173-175

NFScreating NFS shares, 173

datastore properties, 232

datastores, 241-242, 245-246

locking, 236

multipathing, 167

NFSv3, 167, 231, 235-236

NFSv4.1, 167, 231, 235-238

pNFS, 167

security, 236

session trunking, 167

PSA, 209-210, 216SAN

FC, 166, 172, 183

FCoE, 166, 173

iSCSI, 166-167, 169-172, 175-182

NFS, 167, 173

storage adapters, 163-165

storage naming conventions, 168-169

thin provisioning, 183-184

vCenter Server storage filters, 173-175

VSAN, 193-200, 203-207

session trunking, NFS, 235

Page 96: VCP6-DCV Official Cert Guide

748 storage

SIOCbenefits of, 246

configuring, 249-250

Dynamic Queue Depth Throttling versus, 252

enabling/disabling, 247-248

features of, 252

I/O contention environments, 253

monitoring, 250-251

troubleshooting, 421-422

usage cases, 252-253

SPconfiguring for multipathing, 217

VASA, 194-196, 201-202, 206

VSAN, 195

VVOL, 196, 217

SRDS, 414-417storage adapters

displaying, 164

identifying, 163

LUN, 164-165, 169-172

storage devices for adapters, 164-165

thin provisioning, 183-184VAAI, 229-230VASA storage provider, 194, 196, 201-

202, 206vCenter Server, storage filters, 173-175VDP backup storage, 333VMFS, 231

comparing functionality of new/upgraded datastores, 233

datastore properties, 232

datastores, 239-245

RDM, 233-235

upgrading, 232

VAAI, 229-230

VMP, 207VSAN, 193-194

configuring, 197-200

disk groups, 199-200

failure domains, 197, 203-204

SP, 195

virtual machines, 207

VSAN Observer, 204-205

vSpheremonitoring, 399, 402-404

troubleshooting, 399, 402-407, 410, 423-425

verifying configurations, 404-407, 410

VVOL, 231configuring PE, 206

configuring SP, 202

creating, 201, 204

creating SP, 206

SP, 196, 217

VASA storage provider, 194-196, 201-202, 206

Storage vMotionmigrating, 512-514troubleshooting, 512-514virtual machines, 20, 336

strategies for taking the exam, 634-636STS (Security Token Service), 41subscribed content libraries, 612-613,

616Summary tab (DRS clusters), 519-522support bundles, 365swapfile location setting (virtual machine

configurations), 605swapping (memory metric)

ESXi Hosts, 459guest OS paging, 458-459virtual machines, 459vSphere Web Client, 459-461

switchesRestore Standard Switch option (DCUI),

405vDS, 61

adding/removing dvPort groups, 82-86

adding/removing dvUplink groups, 86-89

Page 97: VCP6-DCV Official Cert Guide

749troubleshooting

adding/removing ESXi Hosts, 72-77, 80-82

adding/removing VMkernel ports, 93-97

auto-rollback behavior, 127-129

blocking policies for dvPort groups, 111-112

capabilities of, 65-66

configuring dvPort group settings, 90-92

configuring LACP, 101-104, 107-109

creating/deleting, 68-71

creating/deleting virtual adapters, 93-97

datacenter-level management, 67

dynamic binding, 84

Ephemeral, 85

failover policies, 113

jumbo frames, 123-127

LAG ports, 102-103, 106-109

load balancing, 113

load-based teaming, 66, 114

managing, 67

migrating virtual machines, 98-100

NetFlow, 67

network vMotion, 67

NIOC, 67, 70, 92, 138-143

port blocking, 66, 111-112

port mirroring, 67

port policy settings, 67

port state monitoring, 67

PVLAN, 66, 114-119

security policies/settings, 109-111

static binding, 84

TCP segmentation offload support, 122-123

traffic shaping, 66, 119-121

upgrading, 270

vCenter Servers and long-distance vMotion support, 129-130

virtual machine migration, 67

VLAN, 114-119, 127

vMotion support (long-distance), 129-130

vSS versus, 65-66

virtual switches, configuring across mul-tiple hosts via host profiles, 544-546

vSScapabilities of, 65-66

jumbo frames, 123-127

vDSS versus, 65-66

synchronizing content libraries, 613-614Syslog Collector, troubleshooting,

381-383SystemConfiguration.Administrators

group (SSO), 53SystemConfiguration.BashShellAdminis-

trators group (SSO), 52system traffic, NIOC, 146, 151

T

taking the exam, 634-636tasks, vCenter Server, 484-489TCP segmentation offload, vDS support

for, 122-123templates (virtual machines), 23, 627thin provisioning, 183thumbprints, 372-373tokens, SSO, 55TPS (Transparent Page Sharing),

455-456traffic shaping, vDS, 66, 119-121Transmit Packets Dropped/Receive

Packets Dropped (network metrics), 465

Transmit/Receive Rates (network metrics), 465

transmits (forged), 30troubleshooting

APD state, 423, 424CPU

contention issues, 451-452

limits, 452-454

monitoring performance, 450

reservations, 452-454

shares, 452-454

Page 98: VCP6-DCV Official Cert Guide

750 troubleshooting

datastores, SRDS, 414-415DRS clusters, 495

configurations, 507-511

fault tolerance, 516

target/current host load deviation, 519-522

workload balancing, 497-498

ESXCLI command, virtual machines, 385ESXi Hosts, 426

APD state, 423

determining stability, 361-368

ESXCLI command, 373-376

gathering diagnostics, 361-368

logs, 369-371

monitoring host hardware health, 368

monitoring management agent status, 359-361

monitoring system health, 368

performance, 450

storage, 407-410

Syslog Collector, 381-383

thumbprints, 372

upgrades, 430-431, 434-439

failover, 514-518fault tolerance, 514-518Fibre Channel storage, 424FT, network latency, 389-391HA clusters, 495

capacity, 500-507

configurations, 507-511

failover, 515

failover/redundancy, 500-504

fault tolerance, 515

network configuration, 500-507

iSCSI storage, 424LACP, 425memory, 462

contention issues, 451-452

limits, 452-454

monitoring performance, 450

reservations, 452-454

shares, 452-454

metadata, VMFS, 428-429networks

APD state, 423-424

physical network adapters, 427-428

VLAN, 426

NIOC, 418-420PDL, 409, 423performance

CPU, 450-454, 463-465

ESXTOP, 451-452, 462, 467-468, 471-473

EVC, 473-477

memory, 450-462

network metrics, 465

overview graphs, 483-484

power management policies, 489-490

RESXTOP, 473

storage metrics, 466-467

VMware PerfMon DLL, 450

vRealize Operations Manager, 450, 477-479, 482-483

vSphere Client, 450

vSphere Web Client, 451-452

Windows Performance Monitor, 450

physical network adapters, 427-428port groups, 426-427PSC, 386-388, 431PVLAN connectivity, 422SIOC, 421-422SRDS, 414-417SSO, 378-380storage

APD state, 423-424

ESXI Host storage, 407-410

Fibre Channel storage, 424

iSCSi storage, 406-407, 424

storage vMotion, 512-514support bundles, 365

Page 99: VCP6-DCV Official Cert Guide

751upgrading

Syslog Collector, 381-383vCenter Server, 377-378

connectivity, 380-383

database maintenance, 357-359

events, 484-489

logs, 369-371

monitoring service status, 354-357

ports, 380-381

PostgresSQL scripts and database main-tenance, 359

rollup jobs, 358

tasks, 484-489

upgrades, 430-433

vCLI, 372virtual machines, 384-386, 412-414virtual switches, 426-427VLAN, 422, 426vMA, 372VMFS metadata, 428-429vMotion, 511-514VMware Tools, 388-389vSphere

CPU contention issues, 451-452

CPU limits, 452-454

CPU metrics, 463-465

CPU monitoring, 450

CPU reservations, 452-454

CPU shares, 452-454

ESXTOP, 467-468, 471-473

EVC, 473-477

memory contention issues, 451-452

memory limits, 452-454

memory metrics, 455-462

memory monitoring, 450

memory reservations, 452-454

memory shares, 452-454

network metrics, 465

network resources, 399

networks, 425-426

overview graphs, 483-484

performance metrics, 454-455

physical network adapters, 427-428

port groups, 426-427

RESXTOP, 473

storage, 423-425

storage metrics, 466-467

storage resources, 399

upgrades, 430-441

vCenter Server, 484-489

verifying network configurations, 404-410

verifying storage configurations, 404-410

virtual switches, 426-427

VMFS metadata, 428-429

vRealize Operations Manager, 477-479, 482-483

U

UCS (Unified Computing Systems), vir-tual machines and DirectPath I/O, 599

UMDS (Update Manager Download Ser-vice), 265, 430

unidirectional (one-way) CHAP, 180unmounting

NFS datastores, 241-242VMFS datastores, 240

Update Manager, 263, 345upgrading

ESXi Hostsbaselines, 267

certificates, 280

diagnostic information, 431

ESXCLI, 438-439

ESXi Installer, 434

importing images, 265-266

multiple upgrades, 274-276

remediating objects, 269-270

requirements, 265

scanning vSphere objects, 269

scripted upgrades, 435-437

staging patches/extensions, 269

Page 100: VCP6-DCV Official Cert Guide

752 upgrading

troubleshooting, 430-439

upgrading vDS, 270

upgrading VMware Tools, 271-272

VMware Update Manager, 434

vSphere Auto Deploy, 437

VUM and ESXi Host upgrades, 273

ESXi servers, 518NIOC, 138-143SSO, multi-site SSO installations, 53-54UMDS, 430VMFS, 232vCenter Server

certificates, 280

embedded deployments, 278

embedded Linux vCenter Server backups, 279-283

embedded Windows vCenter Server back-ups, 279-281

external deployments, 278-279

hardware requirements, 284

log bundles, 432-433

troubleshooting, 430-433

upgrade compatibility scenarios, 283-284

upgrade methods, 276-277

vCSA, 281-283vDS, 270virtual machines, 272-273VMware Tools, 271-272VMware Update Manager Utility, 430vSphere

baselines, 267

configuring download sources, 264

diagnostic information, 431

download repository setup, 265

ESXi Hosts, 265-266, 273-276

process of, 284-285

PSC, 431

remediating objects, 269-270

replication on virtual machines, 345

scanning vSphere objects, 269

staging patches/extensions, 269

troubleshooting, 430-441

UMDS and download repository setup, 265

vSphere Web Client, 263

VUM, 263-264, 273uplinks

dvUplink groupsadding/removing from vDS, 86-89

configuring LACP for vDS, 101-104, 107-109

vDS uplinksadding/removing dvUplink groups,

86-89

configuring LACP for dvUplink groups, 101-104, 107-109

editing number of uplinks, 90-91

UPN (User Principal Name), 47USB devices, 597-598USB drives, virtual machine storage, 164user accounts

applying roles to, 16user lists, 6-7VDP, installing, 327

Users group (SSO), 52

V

VAAI (vStorage APIs for Array Integra-tion)

block zeroing, 230enabling/disabling, 230hardware-assisted locking, 230virtual disks, 184, 565XCOPY (full copy command), 229

validating permissions, 17-20VAMI (Virtual Appliance Management

Interface), vSphere Replication, 340-341, 345

vApps and resource pools, 301VASA (vSphere APIs for Storage Aware-

ness) storage provider, 194-196, 201-202, 206

Page 101: VCP6-DCV Official Cert Guide

753vCloud Air

vCenter Converterconverting

collecting diagnostic information during conversion, 564

physical workloads, 557-560

error-handling during conversion, 562-563

modifying resources during conversion, 561-562

resizing partitions during conversion, 564

deploying physical hosts as virtual machines, 563

installing, 556-557usage scenario, 565virtual disk formats, determining, 565

vCenter Orchestrator, 21vCenter Server

connectivity, troubleshooting, 380-383databases, basic maintenance, 357-359deploying

embedded deployments, 278

external deployments, 278-279

events, 484-489Horizon View, 21-22integration, 21-23Linux vCenter Server

embedded backups, 279

pre-upgrade updates, 280-281

vCSA upgrades, 281-283

logs, 369-371configuring, 439-441

log bundles, 366-367, 432-433

monitoring service status, 354-357permissions

adding permissions, 7-10

applying permissions, 10-14

explicit permissions, 6

managing permissions, 7-10

modifying permissions, 7-10

propagated permissions, 6

removing permissions, 7-10

ports list, 380-381PSC, 42-44, 50roles, 14-15rollup jobs, 358security, 39-42SSH login, 378storage filters, 173-175tasks, 484-489troubleshooting, 354-357, 377-378

connectivity, 380-383

database maintenance, 357-359

logs, 369-371

ports, 380-381

PostgresSQL scripts, 359

rollup jobs, 358

upgrading, 276certificates, 280

embedded deployments, 278

embedded Linux vCenter Server backups, 279-283

embedded Windows vCenter Server back-ups, 279-281

external deployments, 278-279

hardware requirements, 284

log bundles, 432-433

troubleshooting, 430-433

upgrade compatibility scenarios, 283-284

upgrade methods, 276-277

vCenter Orchestrator, 21vCloud Air connections, 623-625vDS and long-distance vMotion support,

129-130virtual machine security, 29-30vRealize Operations, 23Windows vCenter Server

embedded backups, 279

pre-upgrade updates, 281

vCLI (vSphere Command-Line Inter-face), 372

vCloud AirDisaster Recovery Service, 625-627

Page 102: VCP6-DCV Official Cert Guide

754 vCloud Air

vCenter Server connections, 623-625vCloud Connector, 619virtual machines

configuring, 627

deploying, 621

migrating to vCloud Air, 621-622

VPN connectionsconnections to on-premise sites, 619-621

verifying, 623

vCPU (virtual CPU), virtual machine configurations, 602

vCSA (vCenter Server Appliance), 281-283

VDP (VMware Data Protection)administration, 333-334backups, 333-335capabilities of, 322-323configuring, 328-334Emergency Restore feature, 338-340installing, 327, 331sizing guidelines, 324snapshots, 325system requirements, 324virtual machines, 335-340

vDS (vSphere Distributed Switches), 61adding/removing

dvPort groups, 82-86

dvUplink groups, 86-89

ESXi Hosts, 72-77, 80-82

VMkernel ports, 93-97

auto-rollback behavior, 127-129capabilities of, 65-66configuring

dvPort group settings, 90-92

LACP, 101-104, 107-109

creating/deleting, 68-71, 93-97datacenter-level management, 67failover policies, 113jumbo frames, 123-127load balancing, 113

load-based teaming, 66, 114managing, 67NetFlow, 67network vMotion, 67NIOC, 67, 70, 92, 138-143ports

adding/removing dvPort groups, 82-86

adding/removing VMkernel ports, 93-97

blocking, 66, 111-112

configuring dvPort group settings, 90-92

configuring general settings, 90-92

configuring LACP for dvPort groups, 101-104, 107-109

dynamic binding, 84

editing number of ports, 92

Ephemeral, 85

LAG ports, 102-103, 106-109

mirroring, 67

per-port policy settings, 67

security policies/settings for dvPort groups, 109-111

state monitoring, 67

static binding, 84

PVLAN, 66, 114-119security policies/settings, 109-111TCP segmentation offload support,

122-123traffic shaping, 66, 119-121upgrading, 270uplinks

adding/removing dvUplink groups, 86-89

configuring LACP for dvUplink groups, 101-104, 107-109

editing number of uplinks, 90-91

vCenter Servers and long-distance vMotion support, 129-130

virtual machines, migrating, 67, 98-100VLAN, 114-119, 127vMotion support (long-distance), 129-130vSS versus, 65-66

Page 103: VCP6-DCV Official Cert Guide

755virtual machines

VECS (VMware Endpoint Certificate Store), 39, 50, 280

verifyingvirtual machines, network resources,

410-414vSphere

network configurations, 404-410

storage configurations, 404-410

vFlasharchitecture of, 301, 304-305ESXi Hosts, 302, 305resource pools, 309vFRC, 301, 304-305, 309-310VMDK, adding vFlash resources to, 309

vFRC (vFlash Read Caches), 301, 304-305, 309-310

vGPU (virtual GPU) and virtual machines, 601

VIB (vSphere Installation Bundles)ESXi Host firewalls, 33Image Builder, 533

virtual adapters, vDS, 93-97virtual datacenter setting (virtual

machines), 627virtual disks

bus sharing, 236-237formats, determining via vCenter

Converter, 565VAAI, 565

virtual disk thin provisioning, 184virtual hardware setting (virtual

machines), 627virtual machines

alerts, 482backup/restore via VDP, 335-340bus sharing, 236-237compatibility options table, 25-26configuring

catalog setting, 627

configuration parameters setting, 605

debugging setting, 604

differentiating configuration settings, 603-610

DirectPath I/O, 599-600

disable acceleration setting, 604

enable logging setting, 604

enabling/disabling advanced settings, 611

latency sensitivity setting, 605

name setting, 627

NIOC, 143-145

NUMA, 608-610

SR-IOV, 600

statistics setting, 604

swapfile location setting, 605

template setting, 627

vCloud Air, 627

vCPU, 602

vGPU, 601

virtual datacenter setting, 627

virtual hardware setting, 627

VMX file settings, 610-611

connecting devices, 26console security, 23content libraries

adding/removing, 618

authentication, 616

defining, 612

ISO files, 612

local content libraries, 612

managing, 613

multi-site library configuration, 614-616

OVF files, 612

passwords, 612

published content libraries, 612-616

roles/permissions, 617

security, 612

storage, 612

subscribed content libraries, 612-616

synchronization, 613-614

copy/paste, 26creating, 18

Page 104: VCP6-DCV Official Cert Guide

756 virtual machines

data access, security, 27deploying

permissions, 18

physical hosts as virtual machines via vCenter Converter, 563

vCloud Air, 621

DirectPath I/O, 599-600disabling unnecessary services, security, 24disk shrinking, 26DRS affinity rules and virtual machine

placement, 588dynamic binding, 84Ephemeral, 85events, 486installing guest OS, 19logging, 26memory, 460-461migrating

cold migration, 19

Storage vMotion, 20

vCloud Air, 621-622

vDS, 67, 98-100

vMotion, 19, 497

monitoring, 579moving to resource pools, 19multi-writer locking, 237-238networks

troubleshooting, 410-414

verifying resources, 410-414

NIOC, 152-153overview graphs, 484performance

performance counters, 27

troubleshooting, 477-479, 482-483

permissions, 6-10PLVAN, 117-118recovering via vSphere Replication,

345-346reservations, 462resource pools, 289

adding/removing virtual machines, 308

configuring, 301

creating/removing, 306-307

customizing, 301

DRS clusters, 293

ESXi Hosts, 293

evenly distributed pools, 299

expandable reservations, 295

hierarchical structures of, 296-297, 311-312

limits, 294

pools with default values, 298

reservation, 294

shares, 293-294

uneven pools, 299

usage scenarios, 311-312

vApps, 301

vFlash, 301, 304-305, 309

vFRC, 301, 304-305, 309-310

virtual machines and resource pools as siblings, 300

VMDK, 309

securitybest practices, 23

communcations, 29

consoles, 23

data access, 27

device connections, 29

disabling unnecessary services, 24

DoS attacks, 29-30

network security policies, 29-30

policies, 28

resource usage, 23

templates, 23

VMware tools installation, 24-27

snapshots, 18, 325-327SP and VVOL, 202, 206SR-IOV, 600static binding, 84storage adapters, 163-165Storage vMotion migrations, 336

Page 105: VCP6-DCV Official Cert Guide

757VMFS (Virtual Machine File Systems)

summaries, 482swapping, 459TCP segmentation offload support,

122-123templates, security, 23troubleshooting, 384-386, 477-479,

482-483upgrading hardware, 272-273USB devices, 597, 598vCloud Air

deploying virtual machines, 621

Disaster Recovery Service, 625-627

migrating virtual machines to vCloud Air, 621-622

vCenter Server connections, 623-625

vCloud Connector, 619

verifying VPN connections, 623

virtual machine configuration, 627

VPN connections to on-premise sites, 619-621

vCPU, 602vGPU, 601VMCI, 29VMCP, 207, 507vMotion, 511-514VMware

security, 24-27

upgrading VMware Tools, 271-272

VMX files, 27VSAN, 207vSphere Replication, 342-346

virtual mode (RDM), 234-235virtual networks, troubleshooting,

410-414virtual NUMA (Non-Uniform Memory

Access), 462virtual SAN (Storage Area Networks),

HA clusters and virtual SAN imple-mentation, 581

virtual switchesconfiguring across multiple hosts via host

profiles, 544-546troubleshooting, 426-427

VLAN (Virtual Local Area Networks)dvPort groups, 86PVLAN, 66, 114-119troubleshooting, 422, 426trunking, 115vDS, 114-119, 127

vMA (vSphere Management Assistant), 372

VMCA (VMware Certificate Authority), 39, 280

configuring, 50-51security, 50-51vSphere Replication, 341

VMCI (Virtual Machine Communication Interface), 29

VMCP (Virtual Machine Component Protection), 207, 507, 580

vmdir (VMware Directory Service), 15-16, 41

VMDK (Virtual Machine Disks)bus sharing, 237LUN, 165vFlash resources, adding to VMDK, 309virtual disk thin provisioning, 184virtual machines, multi-writer locking,

237-238VSSN, 204

VM/DRS groups (DRS clusters), adding/removing, 585-586

VM-FEX (Virtual Machine Fabric Extender), virtual machines and DirectPath I/O, 599

VMFS (Virtual Machine File Systems), 231

datastorescomparing functionality of new/upgraded

datastores, 233

creating, 239-240

deleting, 240

enabling/disabling paths, 244

expanding, 242

extending, 242-243

Page 106: VCP6-DCV Official Cert Guide

758 VMFS (Virtual Machine File Systems)

maintenance mode, 243

multiple datastore usage scenarios, 245

properties of, 232

renaming, 240

unmounting, 240

filters, 174metadata, troubleshooting, 428-429RDM, 233-235upgrading, 232VAAI, 229-230

VM-Host Affinity/Anti-Affinity rules (DRS clusters), 582-584

VMkernelmemory, 460-461migrating virtual network adapters, 405ports

adding/removing from vDS, 93-97

iSCSI port binding, 178-179

system traffic, NIOC, 146, 151VSAN, 197

vMotionconfiguring, 511migrating, 130, 512-514resource maps, 523-524troubleshooting, 511-514vDS and long-distance vMotion support,

129-130virtual machines, migrating, 19, 497

VM-VM Affinity/Anti-Affinity rules (DRS clusters), 584-585

VMwareperformance counters, 27virtual machine security, 24-27VMware Converter, P2V migrations, 556VMware Tools

automated VMware Tools, 271

installing, 388-389

troubleshooting, 388-389

upgrading, 271-272

VMware Update Manager, 430, 434

VMware PerfMon DLL (Performance Monitor dynamic link library), trou-bleshooting performance, 450

VMX files, 26-27, 610-611VOMA (vSphere On-Disk Analyzer),

428-430VPN (Virtual Private Networks) and

vCloud Air connections, 619-623VRA (vSphere Replication Appliances),

deploying, 341, 347vRealize Operations Manager, 23

alerts, 479, 482troubleshooting performance, 450,

477-479, 482-483vROps (vRealize Operations Manager)

and vSphere, 399, 402-404VRS (vSphere Replication Service)

appliances, deploying, 341, 347VSAN (Virtual SAN), 193-194

configuring, 197-200disk groups, 199-200failure domains, 197, 203-204SP, 195virtual machines, 207VSAN Observer, 204-205

vSphereAuto Deploy and ESXi Host upgrades,

437ESXi Hosts

group lists, 7

managing management agents, 359-361

troubleshooting, 366-367

upgrade baselines, 267

user lists, 6

networksmonitoring, 399, 402-404

NIOC, 418-420

SIOC, 421-422

troubleshooting, 399, 402-407, 410, 425-426

verifying configurations, 404-407, 410

Page 107: VCP6-DCV Official Cert Guide

759vSphere

performanceCPU contention issues, 451-452

CPU limits, 452-454

CPU metrics, 463-465

CPU monitoring, 450

CPU reservations, 452-454

CPU shares, 452-454

ESXTOP, 467-468, 471-473

EVC, 473-477

memory contention issues, 451-452

memory limits, 452-454

memory metrics, 455-462

memory monitoring, 450

memory reservations, 452-454

memory shares, 452-454

metrics, 454-455

network metrics, 465

overview graphs, 483-484

power management policies, 489-490

RESXTOP, 473

storage metrics, 466-467

troubleshooting, 450

vRealize Operations Manager, 477-479, 482-483

permissions, 6-10physical network adapters, troubleshoot-

ing, 427-428port groups, troubleshooting, 426-427scanning objects, 269snapshots, 325SSO lists, exporting, 7storage

monitoring, 399, 402-404

troubleshooting, 399, 402-407, 410, 423-425

verifying configurations, 404-407, 410

support bundles, 365TPS, 456troubleshooting

CPU contention issues, 451-452

CPU limits, 452-454

CPU metrics, 463-465

CPU monitoring, 450

CPU reservations, 452-454

CPU shares, 452-454

ESXTOP, 467-468, 471-473

EVC, 473-477

memory contention issues, 451-452

memory limits, 452-454

memory metrics, 455-462

memory monitoring, 450

memory reservations, 452-454

memory shares, 452-454

metrics, 454-455

network configurations, 404-407, 410

network metrics, 465

network resources, 399

networks, 425-426

overview graphs, 483-484

performance, 450

physical network adapters, 427-428

port groups, 426-427

RESXTOP, 473

storage, 423-425

storage configurations, 404-407, 410

storage metrics, 466-467

storage resources, 399

vCenter Server events, 484-489

vCenter Server tasks, 484-489

virtual switches, 426-427

vRealize Operations Manager, 477-479, 482-483

unexposed features, 27upgrading

PSC, 431

troubleshooting, 430-441

upgrading to vSphere 6.0baselines, 267

configuring download sources, 264

download repository setup, 265

ESXi Host images, 265-266

Page 108: VCP6-DCV Official Cert Guide

760 vSphere

ESXi Host upgrade requirements, 265

process of, 284-285

remediating objects, 269-270

scanning vSphere objects, 269

staging patches/extensions, 269

UMDS and download repository setup, 265

upgrading ESXi Hosts, 273-276

upgrading vCenter Server, 276-284

upgrading vDS, 270

upgrading virtual machine hardware, 272-273

upgrading VMware Tools, 271-272

vSphere Web Client, 263

VUM, 263-264

vCenter Server security, 40virtual machine security policies, 28virtual switches, troubleshooting, 426-427VMFS metadata, troubleshooting,

428-429VOMA, 428-430vROps, 399, 402-404vSphere Inventory Hierarchy, permis-

sions, 10-13vSphere Realize Operations, 483vSphere Replication

configuring, 340-341

deploying, 340

failback operations, 346

FastLZ compression library, 321

installing, 340

integrating VMCA with, 341

RPO, 323-324

virtual machines, 342-346

VRA, 341, 347

VRS, 341, 347

vSphere Web Clientballooning, 457

compression, 458

CPU metrics, 463

ESXi server configurations, 511

network metrics, 465

overview graphs, 483-484

SIOC monitoring, 250-251

storage metrics, 467

swapping, 459-461

TPS, 456

troubleshooting performance, 451-452

VMFS datastores, 240

vSphere 6.0 upgrades, 263

vSS (vSphere Standard Switches)capabilities of, 65-66jumbo frames, 123-127quiescing, 342vDS versus, 65-66

VUM (vCenter Upgrade Manager), 263-264, 273

VVOL (Virtual Volumes), 231creating, 201, 204PE, 206SP, 196, 202, 206, 217VASA storage provider, 194-196,

201-202, 206

W

Windows Performance Monitor, troubleshooting performance, 450

Windows vCenter Serverembedded backups, 279pre-upgrade updates, 281

WSFC (Windows Server Failover Clusters), 44, 237

WWN (World Wide Names) and adapters, 166

X-Y-Z

XCOPY (full copy) command (VAAI), 229