vehicle systems - marine generators, air conditioning & … generator... ·  ·...

24
Vehicle Systems 2014 / 2015

Upload: duongkiet

Post on 21-May-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

Vehicle Systems

2014 /

2015

2

Communications Luxury Motor Coaches Limousine Coaches Holiday Homes

Motorized RVs & Mobile Homes ExpeditionVehicles OffGridandRemoteSites

TouringRecreational

Mobile and Stationary Applications

Panda Vehicle Generators

Designed for use in special and diverse areas of the vehicle industry, Fischer Panda generatorsareinstalledinthesmallestandtightestplacesavailableandcanbefoundinnumerousmobileapplicationsworldwide.

MobileBroadcasting RelayandTransmitterSites Commercial Vehicles

Thewater-cooleddieselgeneratorsfromFischerPandaarerenownedworldwideforbeinginnovative,reliableandextremelyquiet.Theproductrangeincludesmorethantwohundredgeneratorsfrom2.5kWto200kW.

FischerPandageneratorsfeatureaneffectivewater-coolingsystemandalightweightcompactconstruction.ThishasmadeFischerPandaaleaderinEuropeformobilesuper-silentdieselgenerators.Thesehighlyprovenmarineandvehiclegeneratorssupplypowertoelectricalsystems,drivesandcompletemobileenergysystems.

FischerPandaGmbHmanufacturescompactandquietdieselgeneratorsformarineandvehicleapplications.Thesearesoldinmorethaneightycountriesworldwideunderthetradename“FischerPanda”.

Thecompany,basedinPaderborn/Germany,wasfoundedin1977underthenameIcemasterGmbHandrenamedasFischerPandaGmbHin2007.

High Performance Extremely Quiet Water-Cooled

Compact Light WorldwideServiceNetwork

3

Imagecourtesy:MOSTMobileSpecialsGmbH

Emergency Services Specialist Services Promotion MobileStages TradeShowVehicles Formula1TeamVehicles

Command Centres Border Control & Customs Mobile Blood Donor Units

Environmental Monitoring Railway&TrackMaintenance TacticalShelters

4

FischerPandasuppliesinstallationkitswithallthenecessarycables,hoses,connectionpiecesandaccessoriestoensurethat the system can be correctly installed inside the vehicle or externallyonthechassis.Specifichoseandcablelengthsareavailableonrequest.

Powerful Energy Systems

Installation Kits

Custom services for special requirements

FischerPandaoffersextensiveservicesforadaptinggeneratorsforusewithspecialequipmentandcommercialapplications.Thisincludeselectro-magnetichydrauliccouplingsfordrivingmechanical-hydraulicpumpsandalsomountingslidestoprovideaccesstothegeneratorwhileservicing.

FischerPandaGeneratorsformthebackboneofourintelligentandinnovativesolutionswhetheryouareupgradinganexistinginstallation,connectingtoanothersystemorensuringyouhavesufficientenergywhenalandpowerconnectionisnotavailable.ReadmoreaboutthisintheFischerPandaSystemsBrochure.

Installation Services and Support

5

Global Service Directory

Withacoordinatednetworkofdistributors,dealersandservicestations,FischerPandahastrainedspecialistsandaworldwidedealernetworkreadytohelp,giveadviceandrecommendthebestservicestationdependingonthelocationofyourvehicleoryacht.Theywillalsobeabletoorganiseandcoordinateresourcesandpartssowecanprovideyouwiththebestservice,whereveryouare.TheGlobalServiceDirectorycanbedownloadedfromthecompanywebsiteat:http://www.fischerpanda.de/globalservice

Service Kits

FischerPandaServiceKitscontainoriginalpartswhichmeettherequiredspecificationsandaresuitedfornormalworkshopservicing.FischerPandaService“Plus”Kitscontainalltherelevantsparepartsforthefirst600hourserviceinterval.ServicePluskitsaresuppliedinahandywaterproofplasticboxsoalltheitemsareprotectedduringstorage.TheFischerPandaInstallationGuidecanbedownloadedfromthecompanywebsiteat:http://www.fischerpanda.de/installation

Fischer Panda SOS-24/7 Hotline

Forurgentenquiriesorgeneratorfailureoutsideournormalbusinesshours,youcanringtheFischerPandainternationalswitchboardon+4952549202-767(SOSonakey-operatedtelephone).Pleaseleaveyourname,numberandthepurposeofyourcallontheanswerphone/voicemail.Thisserviceisoperated24/7byemployeesatFischerPanda.

6

Lessspacerequiredforinstallation Water-cooledACwinding Canbeinstalledintightspaces

Hermeticallysealedcapsule Allconnectionspre-fittedoncapsule Modulardesignensuresinstallationflexibility

Noappreciablewarmingoftheinstallationarea Super-silentsoundinsulationsystem Water-cooledsilencer(upto25kW) Nocoolingaircirculatingwithincapsule

Super-Silent Sound Insulation System

ThemostsignificantadvantageofallFischerPandageneratorsisthelowsoundlevel.Manypartsarerequiredtoworktogethertoachievethisresult.Aflowofcoolingairisnotrequiredinsidethecapsule,thisalsohelpsmaintainconstantambienttemperatures.Anefficientwater-coolingsystemrequiresthattheradiatorisinstalledseparatelyfromthegenerator.

FischerPandageneratorsupto25kWaredeliveredwithafibreglassGFKsoundinsulationcapsulewith“3D”soundinsulationmaterialasstandard(soundinsulationmaterial“4DS”isavailableasanoption).

From30kW,thecapsuleisdeliveredasastainlesssteel-version MPL.Dependingonthesizeofthegenerator,theMPLsound-insulationcapsuleconsistsof6to11parts.MPLcapsulesarealsoavailable(atanadditionalcost)forgeneratorsfrom6kWto25kW.

Variousversionsofsoundinsulationmaterialareavailable:3D:3layers,upto25mmthick4DS:upto5layers,upto40mmthick6DS:upto6layers,upto60mmthick

Water-cooled Exhaust Silencer

PVMV-N,PVK-UandPVK-UKgenerators(upto25kW)arefittedwithaninternalwater-cooledexhaustsilencer.

Water-cooledpre-silencer

Cooled exhaust gases

Hot exhaust gases

Main silencer

Compact, Quiet Vehicle Generators

7

Theradiatormustbeinstalledwheregoodaccessforfreshaircirculationisguaranteed.Thebestlocationishorizontallyontheroofofthevehicle.Theradiatorhasanintegratedexpansiontank.

Aradiatorcanbefittedverticallyonthevehiclewhenthereisnospaceontheroof.

Roof-mountedradiatorwithintegratedexpansiontank

PandaGenerator

Vertically

mounted

radiator

Expansiontank (optional)

When sufficient clearance is available, the radiator may bemountedunderthechassis.Theairmustbeabletocirculatecorrectlysowarmairdoesnotflowbackovertheradiator.

PandaGenerator

Expansiontank

Radiator mounted

underneath

vehicle

PandaGenerator

Vehicle Installation: Vertically mounted radiator

Vehicle Installation: Chassis-mounted

Vehicle Installation: Roof-mounted radiator

8

AC Windings available in three versions to suit your needs:

Single-phase windings

Three-phase windings

Single-phase plus three-phase (Panda “DVS” Dual Voltage System) windings

High performance windings

The230V50Hz,(120/240V60Hz)singlephasewindingsarestandardforgeneratorsupto25kW.Athree-phaseversionshouldbeconsideredabove12kW,asthePandageneratorpermitsasymmetricalloadsupto50%perphase.AHybridPowerSystemshouldalsobetakenintoconsideration(seepage12)forsmalltomiddlerangeon-boardpowersystems.

The400VAC50Hz,(208V60Hz)three-phasewindinghasthehighestlevelofefficiencyandthebestqualities.Thiswindingcanalsosupplysingle-phaseACwiththeappropriatephasedistribution.Athree-phasegeneratorshouldalwaysbechosenabove25kW(fromPanda30).

The“DVS”Combined-Windingisaspecialversionconsistingofbothasingle-phaseanda400Vthree-phasewinding.This version is only available from Fischer Panda and without additional cost.Three-phasemotorssuchascompressorscanbeusedandaseparatesingle-phasewindingcansupplythefullnominalperformanceofthegeneratorwithout“asymmetricalloadproblems”onaphase.Thissimplifiestheelec-tricalinstallation.

Note:GeneratorswithDVSwindingssupplyonly85%ofthenominalperformancecomparedtothosewithjustasingleorthree-phasewinding.

lighting

airconditioners

compressors electric motors

ovens

boilers ventilators

satellite receivers

lighting satellite receivers

ovensairconditioners

9

Reliable and durable

Basic and Premium generators - All the benefits of the asynchronous generator and more:

iSeries generators - the next generation of compact, super-silent and powerful generators from Fischer Panda.

The Panda offers all the advantages of the classic asynchronous generator. The asynchronous generator delivers high standards regarding both operational security and life. Therefore, the asynchronous generator is often the preferred choice when a high degree of safety and reliability is demanded.

Fischer Panda warrants the rotor, often the most sensitive part of other generator systems, with a lifetime guarantee. Furthermore, the asynchronous generator continues to be the best suited for water-cooling as the copper winding is the only component that produces the heat via the stator. The electrical generator is warranted with a 5-year guarantee against corrosion.

BasicLinegenerators(ND)arenotfittedwithelectronicspeedcontrol.Othermajorpartssuchasmotor,generator,soundinsulationcasing,andwater-cool-ingareidenticaltoPremiumLinemodels.Thevoltagetolerancelieswithinanacceptable range of ±8%(similartoashorepowerconnection).

ThePandaPremiumLinegenerators(NE)havebeenfittedwiththetriedandtestedVCS(VoltageControlSystem)formanyyears.Theenginespeedispro-gressivelycontrolledandthegeneratorcanachieveupto15%moreeffectiveperformancethananon-regulatedgenerator.TheVCSadjuststhevoltagewithatoleranceof±3Vintherangeupto80%ofthenominalperformance.Controllingthespeedalsohasapositiveeffectonexhaustemissions.TheVCSandcapaci-tors,usedforboostingthestartingcurrent,areusuallyfittedinsideanexternalACcontrolbox.

Premium (and HD) Line: Fischer Panda generators with VCS Voltage Control

Generators with variable speed technology

ThePandaiSeriesgeneratorshavebeenespeciallydesignedtobecompact,quietandpowerful-withupto30%weightandspacesavings!Theyareidealforsuperyachtownerslookingforanightgeneratorwithlowoperatingsoundlevelsandvibra-tions.Thei-seriesgeneratorsarecharacterisedbytheirmod-ern,innovativeandenvironmentallyfriendlyinvertertechnol-ogy.Aparallelconnectionwithoutadditionalcablesispossibleusingspecialinverters. Thespeedofthedieselengineisadjustedaccordingtotheuser’schangingpowerrequirementswhiletheoutputvoltagealwaysremainsconstantfromtheinverter.Variablespeedcon-trol considerably reduces exhaust emissions and fuel consump-tionincomparisonwithatraditionalgeneratorwithafixedspeed.Themaximumspeedoftheengineis2800rpm.Theelectricloadisprovidedwithaconstantoutputvoltageof 230V/50Hzor400V/50Hzviaaninverter.

Highlyefficient-maximumenergy Variablespeed-load-dependent Meets latest emission standards

Modulardesignensuresinstallationflexibility Extremelystablevoltageandfrequency Highstartingcapacityforair-conditioners

Overload protection Water-cooled Short-circuit stability

Highest operating protection High protection rating Brushless

Perfect sine wave No rotating coils No diodes

Precise control No signal noise Highly efficient

10

The patented Voltage Control System (VCS) from Fischer Panda

Fischer Panda generators combine all the advantages of the asynchronousgeneratorwiththevoltagecontrolofasynchronousgenerator.AsynchronousPandageneratorssupplyaparticularlycleansinewavewhichisessentialforthesmoothrunningofsensitiveelectronicdevicessuchasairconditioners,chargingdevices,laserprinters,etc.Generatorsinthiscategoryhaveachievedexceptionalresultsinnumeroustests.

Perfect Sine Wave

The outstanding sine wave of the Fischer Panda Generator

Monitoring and operation

Voltage Stability with patented Voltage Control System (VCS) tolerance ± 3 V

Generator Signal Interface

For more than ten years, Fischer Panda generators have used the patentedelectronicVoltageControlSystem(VCS)for controllingthegeneratorandengine.Theenginespeedispro-gressively controlled and the output voltage of the asynchronousgeneratoriswithinatoleranceof±3V.

Generator SignalInterface (GSI) for

Fischer Panda gen-erators

TheGeneratorSignalInterface(GSI)enablestheFischerPandaGeneratortobeconnectedintoapowermanagementand controlnetwork.Otherdevicessuchasprogrammablelogiccontrollers(PLCs)canthenbeusedtocontrolandmonitorthegeneratorremotely.Thepotential-freecontactsenableexternalapplicationstoaccessthestatussignalsfromthegenerator.Externalapplicationscanalsostartandstopthegenerator.

11

Engine coolant temperatureEngine exhaust temperatureEngine oil pressure

Remote Control Panel for Panda 4500

Remote Generator Control Panel for Panda 8000 and above

Panels for ease of use and operation

iControl Panel for i-Series Generators “AGT Control” Remote Control Panel

FischerPandapanelsallowthegeneratortobeoperatedfromanotherlocationwithinthevehicle.Optionsareavailableforconnectingpanelsinparallelorwithaslavepanel.Thegeneratorcanthenbeoperatedfromtwolocationsforevenmoreflexibility.Apanelcanbeinstalledinthecabinandanotherpanelcanbefittedintheinstallationarea.Importantoperatinginformationisalsodisplayed.

Batterycharging230VoltACCoolantleakage(optional)

Thegeneratorswitchesitselfoffwhenanyofthesefunctionsarenotinthenormalstate.Thestandardremotecontrolpanelcanbeupgradedwithanadditionalautomaticmoduletoenablethegeneratortobestarted(andstopped)byexternaldevicessuchastimers.

Thestandardversionremotecontrolpanel(formodelsPanda8000andabove)monitorsthefollowingfunctions:

12

Asynchronous Generators

Suitedfortypicalpowerapplicationsrequiringcontinuouspowerand higherstartingcapabilities

Generators for all types of commercial and recreational vehicle applications

Battery12 V / 24 V / 48 V DC Inverter

3000rpm-50Hz-230V3000rpm-50Hz-400V3600rpm-60Hz-120/240V3600rpm-60Hz-208VAC

Toprovideyouwithanidealpowersolutionforyourvehicle,differenttypesofgeneratorsforprovidingon-boardpowerareavailable:

Panda Basic Line VehicleAsynchronousGeneratorswithoutvoltagecontrol

Voltagetolerance±8%

Battery Powered On-board Systems Power for Domestic Electrical Consumers

DC Generators

Panda AGT-DCHybridVehicleBatteryChargingGenerators

12V/24V/48V)(othervoltagesonrequest)

Longer lifespan for generator Reduced maintenance costs Reduced environmental impact

Reduced exhaust emissions Reducedfuelconsumption Less noise on board & outside

Longerbatterylife Smallerbatterybankpossible

Upto30%smallerandlighter Automaticstartasstandard (optionalmanualstart)

Hybrid AC Energy

Fischer Panda battery charging generators produce direct current andgenerallyfunctionaspartofaHybridPowerSystem.Batterylevelsaremonitoredandautomaticallychargedbythegenerator.Aninvertersuppliesenergytothe230Vconsumerson-board.Thesesystemsareidealforpowerdemandsthatvaryanddonotrequireageneratortoconstantlyrunthroughouttheday.

Advanced Generator

Technology (AGT)

only from

Fischer Panda

Complete Programme

Asynchronous Generators

12 V / 24 V / 48 V DC

HybridPower:Powerfulbattery-charginggenerators.Idealforbatterysystemswhichmayberequiredtopowerlargerconsumersforshort periods during the day

13

Asynchronous Generators Inverter Generators

Generatorswithvariablespeedforlowerfuelconsumption,quieteroperationandreduced exhaust emissions

Suitedforheaviercommercialapplicationswithlonglifespans

Suitedforapplicationsrequiringcontinuouspowerandhighstartingcapabilitieswithaverystable voltage supply

1500rpm-50Hz-230V1500rpm-50Hz-400V1800rpm-60Hz-120/240V1800rpm-60Hz-208VAC

Fischer Panda AC Generatorsaredesignedforcontinuousoperation.Theyproducealternatingcurrentdirectlywhilerunning.Notonlyforoperatingdomesticelectricalappliancesandelectriccooking,theyaretherightchoiceforoperatingdemandingconsumerssuchasair-conditioningandcompressors.Theyalsoproduceaverycleansinewave,idealforsensitiveelectronicequipment.

AC Energy Direct

Panda i-SeriesVehicleGeneratorswithvariablespeedtechnology

Voltage tolerance ±3 V

Panda Basic Line VehicleAsynchronousGeneratorswithoutvoltagecontrol

Voltagetolerance±8%

Panda 1500/1800rpmSeriesAsynchronousVehicleGeneratorswithvoltagecontrol

Voltage tolerance ±3 V

Panda Premium LineAsynchronousVehicle Generatorswithvoltagecontrol

Voltage tolerance ±3 V

50Hz-230V50Hz-400V60Hz-120/240V(upto15000i)60Hz-230Vvariablespeed-loaddependent

3000rpm-50Hz-230V3000rpm-50Hz-400V3600rpm-60Hz-120/240V3600rpm-60Hz-208VAC

Power for Domestic Electrical Consumers

Asynchronous Generators Inverter Generators

230 V / (120 / 240 V) AC

14

Panda PVK-U

Designedforexternalmounting Assemblyboltspre-fittedtohousing Metalcapsulewithaheavy-dutycover

Wideaccesshatchforeasieraccess Water-cooledexhaustsilencerinsidecapsule Noadditionalexhaustsilencerrequired Requiresexternalradiator

PandaVehicleGeneratorwithinternalwater-cooledsilencerformountingexternallyonthevehiclechassis.

Suitableforinternalinstallation Requiresexternalradiator Easy to install

Panda PVM-NE

Vehiclegeneratorwithsoundinsulationcapsule,integratedwater-cooledverticallymounted pre-silencerandmainsilencer.

Panda PVMV-N

FischerPandageneratorsareofcompactconstructionandhighlysuitedforapplicationswithlimitedspaceavailable.Theyareavailableforinstallationinsidethevehicleandformountingexternallyonthechassis.ThemodularversionsPVMV-N,PVM-NEandPVK-Uhavebeendesignedtobeinstalledwithanexternalradiator.Themosteffectivecoolingisusuallyachievedusingacoolingsystemwitharoof-mountedradiator.

Fischer Panda generators are available in

different versions to suit your needs

Complete Programme

Thisgeneratortypeisidealforinstallingontruckswithlimitedspacebetweenaxles.Theheavy-dutyhousingisalsosuitableforexpeditionvehicles.

ThePVM-NEisthestandardversionforgeneratorsabove30kW.ThePVM-NEissimilartothePVMV-Nwiththeexceptionthatthesilencerisnotwater-cooledandexternallymountedonthecapsule.

Easy to install Requiresexternalradiator Suitableforkeelcoolinginships

Suitableforinternalinstallation Bestchoice,whenspaceisavailableinsidethevehicle Completewater-cooledsilencerinsidecapsule

Glass-reinforcedplastic(GRP)capsulestandardformodelsupto12kW

Stainlesssteelcapsule(MPL)formodelsfrom15kWand above

Thegeneratormustbeinstalledinawell-ventilatedareabecauseheatisabsorbedbythesilencer.Anadditionalsilencerisnotnecessary.Thegeneratorishousedwithinasoundinsulationcapsule.

15

Panda PVK-UK Panda Vehicle Generator “Compact Construction” with integrated cooling system for mounting externally on the vehicle chassis.

Panda PSCPanda Self-Contained generators are complete “turnkey” units fitted with an integrated cooling system, fuel tank and electrical cabinet.

Integratedfueltank Verticallyorhorizontallymountedradiator Suitableforexternalmounting

Soundinsulationcapsule Water-cooledexhaustsilencerinsidecapsule Noadditionalexhaustsilencerrequired Integratedradiatorandcoolingsystem

Designedforexternalmounting Assemblyboltspre-fittedtohousing Metalcapsulewithaheavy-dutycover

Wideaccesshatchforeasieraccess Soundinsulationcapsule Water-cooledexhaustsilencerinsidecapsule

Noadditionalexhaustsilencerrequired Integrated radiator and cooling system

16

Technical Data for Fischer Panda Vehicle Generators

iSeries - Inverter Line

Fischer Panda iSeries generatorstakefulladvantageofmoderndieselengines designed to run at lowerspeeds and meet current emission standards. Engine speed is adjustedautomatically according to theelec-tricalloadwhichmakesiteconomicaltorun.Thesegeneratorsareidealforpoweringvaryingloadprofiles.

*) For inverter generators: outputperformance is calculated with aCosPhifactor0.8upto40°Cambi-enttemperature,otherwisecalculatewithfactor1.0upto50°C.

Basic Line VersionsFischer Panda “Basic Line” version generators are ideal for the price-conscious customer. The genera-torsarenotfittedwithanelectronicspeed control. Voltage tolerancelies within an acceptable rangeof ±8%which is similar to a landpower connection. Major parts:engine, generator, sound enclosure casingandwater-coolingareidenti-caltotheNEmodels.

Premium Line VersionsThese asynchronous generators are fittedwiththePandaVoltageCon-trol System (VCS) which progres-sively controls the engine speed.This has an enormously positiveeffectontheexhaustemissionsandthegeneratorachievesupto15%more effective performance thanother non-controlled generators.TheVCSadjuststhevoltagewithatolerance of ±3 V in the range up to 80%ofthenominalperformance.The VCS and the capacitors (usedfor boosting the starting current)are fitted in an external AC con-trol box for the standard versions of Premium Line generators up to Panda18NE.

For asynchronous generators (uptoandincludingPanda15000),theKVAiscalculatedwithCosPhi0.85forashortstartingperformanceofinductive consumers. Otherwiseit shouldbe calculatedwith factor1.0. Generators above and includ-ing Panda 16 are calculated withanoptionalstartperformancewithcompensation or starting currentbooster,otherwiseitshouldbecal-culatedwithafactorof1.

PandaGenerator

Model / Type

Generator Nominal Performance

Volta

ge T

oler

ance

Engi

neM

anuf

actu

ter

Engi

ne T

ype

Disp

lace

men

t cm

3

No.ofC

ylinde

rs

Soun

dLevel[dB

A]

(7m/3m

/1m

)

PVMV-N PVM-NE PVK-U PVK-UKHP1 HP3 DVS

230 V

1 Phase

50 Hz

400 V

3 Phase3 Phase

50 Hz

230/400 V

1 + 3 Phase

50 HzApprox.Capsule

Dimensions

LxWxH)mm Weigh

tincl.

Capsule(kg)

Stan

dardCap

sule

Type

Stan

dardSou

nd

Insulatio

n Approx.Capsule

Dimensions

(LxWxH)mm Weigh

tincl.

Capsule(kg)

Stan

dardCap

sule

Type

Stan

dardSou

nd

Insulatio

n Approx.Capsule

Dimensions

(LxWxH)mm Weigh

tincl.

Capsule(kg)

Stan

dardCap

sule

Type

Stan

dardSou

nd

Insulatio

n Approx.Capsule

Dimensions

(LxWxH)mm Weigh

tincl.

Capsule(kg)

Stan

dardCap

sule

Type

Stan

dardSou

nd

Insulatio

n

(kW) (kVA*) (kW) (kVA) 1-phase 3-phase

Perfect Power / i-Serie Panda Marine Generators

Panda5000i 0-4,0 5 - - - - ±3 V Kubota EA300 309 1 54/64/68 780x477x430 120 GFK 4DS 750x440x440 140 MPL 4DS 1270x439x440 176 MPL 4DS

Panda8000i 0-6,4 8,0 - - - - ±3 V Kubota Z482 479 2 52/62/67 760x515x609 190 GFK 4DS request request MPL 4DS 1300x534x620 315 MPL 4DS

Panda10000i 0-8,0 10,0 0-8,0 10,0 - - ±3 V Kubota Z602 599 2 52/62/67 790x515x609 195 GFK 4DS request request MPL 4DS 1426x531x620 request MPL 4DS

Panda15000i 0-12,0 15,0 0-12,0 15,0 - - ±3 V Kubota D902 898 3 54/64/68 870x515x614 205 GFK 4DS 910x530x600 request MPL 4DS 1515x530x600 request MPL 4DS

Panda25i 0-20,0 25,0 0-20,0 25,0 - - ±3 V Kubota V1505 1498 4 request request request GFK 4DS request request MPL 4DS request request MPL 4DS

Panda45i - - 0-36,0 45,0 - - ±3 V Kubota V2403T 2434 4 request request request MPL 4DS 1442x660x880 662 MPL 4DS

Basic Line Generators - 3000 rpm - 50 Hz Panda Vehicle Generators without electronic regulation

Panda4,5ND 3,8 4,5 - - - - ±8% Farymann 18W430 298 1 54/64/68 765x450x560 161 GFK 4DS 800x440x570 195 MPL 4DS request request MPL 4DS

Premium Line Panda NE Generators - 3000 rpm - 50 Hz Panda Vehicle Generators with VCS Voltage Control System

Panda8000 6,8 8,0 6,8 8,0 6,0 6,0 ±3 V Kubota Z482 479 2 52/62/67 870x515x634 230 GFK 4DS 870x523x580 279 MPL 4DS 1330x522x620 352 MPL 4DS

Panda10000 8,0 9,4 8,0 9,4 7,0 7,0 ±3 V Kubota Z602 599 2 52/62/67 910x515x630 235 GFK 4DS request request MPL 4DS 1516x522x620 375 MPL 4DS

Panda12000 10,2 12,0 10,2 12,0 9,0 9,0 ±3 V Kubota D722 719 3 53/63/67 950x515x629 253 GFK 4DS 960x530x625 317 MPL 4DS 1566x530x625 411 MPL 4DS

Panda15000 12,7 15,0 12,7 15,0 11,1 11,1 ±3 V Kubota D902 898 3 54/64/68 1000x515x634 298 GFK 4DS 1000x530x630 377 MPL 4DS 1606x522x630 436 MPL 4DS

Panda18 15,3 18,0 15,3 18,0 13,5 13,5 ±3 V Kubota D1105 1123 3 55/65/69 1100x540x680 415 MPL 4DS 1100x560x680 440 MPL 4DS 1736x560x680 544 MPL 4DS

Panda 24 20,4 24,0 20,4 24,0 18,0 18,0 ±3 V Kubota V1505 1498 4 55/65/69 1220x540x680 465 MPL 4DS 1225x542x684 492 MPL 4DS 1854x542x684 492 MPL 4DS

Panda30 25,5 30,0 25,5 30,0 22,4 22,4 ±3 V Kubota V1505T 1498 4 55/65/69 1270x570x700 512 MPL 4DS 1270x570x690 530 MPL 4DS 1970x564x640 687 MPL 4DS

Panda40 - - 37,0 43,5 - - ±3 V Lombardini LDW2204T 2199 4 57/61/71 1405x690x780 765 MPL 4DS request request MPL 4DS request request MPL 4DS request request MPL 4DS

Panda60 - - 51,0 60,0 - - ±3 V Merc.Benz OM602A 2874 5 58/68/72 1665x730x810 933 MPL 4DS request request MPL 6DS request request MPL 6DS

Panda75 - - 63,7 75,0 - - ±3 V Merc.Benz OM603A3.5 3500 6 58/68/72 1845x730x830 1100 MPL 4DS request request MPL 6DS request request MPL 6DS

Panda100 - - 85,0 100,0 - - ±3 V Merc.Benz OM603A3.5 3500 6 58/68/72 1720x780x860 1150 MPL 4DS request request MPL 6DS request request MPL 6DS

Panda HD - 1500 rpm - 50 Hz Panda Vehicle Heavy Duty Generators with VCS Voltage Control System

Panda7,5-4 6,5 7,6 6,5 7,6 - - ±3 V Kubota D1105 1123 3 52/62/66 1055x515x665 338 GFK 4DS request request MPL 4DS request request MPL 4DS

Panda9-4 8,0 9,4 8,0 9,4 - - ±3 V Kubota D1105 1123 3 52/62/66 1140x730x700 389 MPL 4DS 1100x560x680 544 MPL 4DS request request MPL 4DS

Panda12-4 10,5 12,3 10,5 12,3 - - ±3 V Kubota V1505 1647 3 52/62/66 1170x540x 700 435 MPL 4DS request request MPL 4DS request request MPL 4DS

Panda17-4 14,7 17,5 14,7 17,5 - - ±3 V Kubota V2203 2197 4 53/63/67 1300x620x800 581 MPL 4DS request request MPL 4DS request request MPL 4DS

Panda22-4 18,6 21,9 18,6 21,9 - - ±3 V Kubota V2403 2434 4 53/63/67 1390x730x770 643 MPL 4DS 1390x600x760 643 MPL 4DS request request MPL 4DS

Panda30-4 25,0 29,4 25,0 29,4 - - ±3 V Mitsubishi MIS4S 3331 4 request 1473x690x890 800 MPL 4DS request request MPL 4DS request request MPL 4DS

Panda40-4 - - 35,0 41,1 - - ±3 V Mitsubishi MIS4SDT 3331 4 request 1560x710x950 867 MPL 4DS request request MPL 4DS request request MPL 4DS

Panda50-4 - - 40,0 47,0 - - ±3 V JCB NA-47 4399 4 request 1581x730x980 891 MPL 4DS request request MPL 4DS request request MPL 4DS

Panda60-4 - - 50,0 59,0 - - ±3 V Deutz BF4M2012C 4040 4 request 1885x790x1000 1298 MPL 6DS request request MPL 6DS request request MPL 6DS

Panda70-4 - - 61,0 72,0 - - ±3 V Deutz BF4M1013E 4764 4 request request request MPL 6DS request request MPL 6DS request request MPL 6DS

Panda85-4 - - 73,0 86,0 - - ±3 V Deutz BF4M1013EC 4764 4 request request request MPL 6DS request request MPL 6DS request request MPL 6DS

Panda110-4 - - 92,0 109,0 - - ±3 V Deutz BF6M1013E 7146 6 request request request MPL 6DS request request MPL 6DS request request MPL 6DS

Panda130-4 - - 111,0 130,0 - - ±3 V Deutz BF6M1013EC 7146 6 request request request MPL 6DS request request MPL 6DS request request MPL 6DS

Panda200-4 170,0 200,0 ±3 V Deutz BF6M1015E 11910 6 request request request MPL 6DS request request MPL 6DS request request MPL 6DS

Hybrid Power / Panda AGT-DDC Battery Charging Generators with VCS Voltage Control System

PandaGenerator

Model / Type AGTGeneratorwithsoundinsulationcapsule N

ominal

Perf

orm

ance

(kW)

Conti

nuou

sPe

rfor

man

ce

(kW)

Nom

inalvoltage

(DC)

Cons

tant

cur

rent

rate(A

)

Engi

ne R

evol

u-tio

ns

Volta

ge

Tole

ranc

e

Engi

neM

anuf

actu

ter

Engi

ne T

ype

Disp

lace

men

t cm

3

No.ofC

ylinde

rs

Soun

dLevel

[dBA

] (7

m/3m

/1m

) Approx.Capsule

Dimensions

(excl.fittings)

LxWxH(mm) Weigh

tincl.

Capsule(kg)

Stan

dardCap

sule

Type

Stan

dardSou

nd

Insulatio

n

Approx.Capsule

Dimensions

(excl.fittings)

LxWxH(mm) Weigh

tincl.

Capsule(kg)

Stan

dardCap

sule

Type

Stan

dardSou

nd

Insulatio

n

Approx.Capsule

Dimensions

(excl.fittings)

LxWxH(mm) Weigh

tincl.

Capsule(kg)

Stan

dardCap

sule

Type

Stan

dardSou

nd

Insulatio

n

Approx.Capsule

Dimensions

(excl.fittings)

LxWxH(mm) Weigh

tincl.

Capsule(kg)

Stan

dardCap

sule

Type

Stan

dardSou

nd

Insulatio

n

AGT-DC4000-12V 4 3,2 12 220 2400-3000 ±3 V Kubota EA300 309 1 55/65/69 770x450x430 120 GFK 4DS request request MPL 4DS 1210x450x440 148 MPL 4DS

AGT-DC4000-24V 4 3,2 24 110 2400-3000 ±3 V Kubota EA300 309 1 52/62/67 770x450x430 120 GFK 4DS request request MPL 4DS 1210x450x440 148 MPL 4DS

AGT-DC5000-12V 4,5 3,6 12 250 1800-2200 ±3 V Kubota Z482 479 2 52/62/67 750x505x615 189 GFK 4DS request request MPL 4DS request request MPL 4DS

AGT-DC6000-24V 5,5 4,8 24 170 2400-3200 ±3 V Kubota Z482 479 2 52/62/67 760x515x609 189 GFK 4DS request request MPL 4DS request request MPL 4DS

AGT-DC8000-24V 8 6,4 24 220 2200-2600 ±3 V Kubota D722 719 3 53/63/67 860x515x614 216 GFK 4DS request request MPL 4DS request request MPL 4DS

AGT-DC12000 12 request request ±3 V Kubota D902 898 3 54/64/68 request request GFK 4DS request request MPL 4DS request request MPL 4DS

AGT-DC14000 14 request request ±3 V Kubota D1105 1123 3 55/65/69 request request GFK 4DS request request MPL 4DS request request MPL 4DS

AGT-DC16000 16 request request ±3 V Kubota V1505 1498 4 55/65/69 1100x550x690 366 MPL 4DS request request MPL 4DS request request MPL 4DS

AGT-DC25000 25 request request ±3 V Kubota V1505T 1498 4 55/65/69 request request MPL 4DS request request MPL 4DS request request MPL 4DS

AGT-DC28000 28 request request ±3 V Kubota V2403 2434 4 55/65/69 request request MPL 4DS request request MPL 4DS request request MPL 4DS

17

PandaGenerator

Model / Type

Generator Nominal Performance

Volta

ge T

oler

ance

Engi

neM

anuf

actu

ter

Engi

ne T

ype

Disp

lace

men

t cm

3

No.ofC

ylinde

rs

Soun

dLevel[dB

A]

(7m/3m

/1m

)

PVMV-N PVM-NE PVK-U PVK-UKHP1 HP3 DVS

230 V

1 Phase

50 Hz

400 V

3 Phase3 Phase

50 Hz

230/400 V

1 + 3 Phase

50 HzApprox.Capsule

Dimensions

LxWxH)mm Weigh

tincl.

Capsule(kg)

Stan

dardCap

sule

Type

Stan

dardSou

nd

Insulatio

n Approx.Capsule

Dimensions

(LxWxH)mm Weigh

tincl.

Capsule(kg)

Stan

dardCap

sule

Type

Stan

dardSou

nd

Insulatio

n Approx.Capsule

Dimensions

(LxWxH)mm Weigh

tincl.

Capsule(kg)

Stan

dardCap

sule

Type

Stan

dardSou

nd

Insulatio

n Approx.Capsule

Dimensions

(LxWxH)mm Weigh

tincl.

Capsule(kg)

Stan

dardCap

sule

Type

Stan

dardSou

nd

Insulatio

n

(kW) (kVA*) (kW) (kVA) 1-phase 3-phase

Perfect Power / i-Serie Panda Marine Generators

Panda5000i 0-4,0 5 - - - - ±3 V Kubota EA300 309 1 54/64/68 780x477x430 120 GFK 4DS 750x440x440 140 MPL 4DS 1270x439x440 176 MPL 4DS

Panda8000i 0-6,4 8,0 - - - - ±3 V Kubota Z482 479 2 52/62/67 760x515x609 190 GFK 4DS request request MPL 4DS 1300x534x620 315 MPL 4DS

Panda10000i 0-8,0 10,0 0-8,0 10,0 - - ±3 V Kubota Z602 599 2 52/62/67 790x515x609 195 GFK 4DS request request MPL 4DS 1426x531x620 request MPL 4DS

Panda15000i 0-12,0 15,0 0-12,0 15,0 - - ±3 V Kubota D902 898 3 54/64/68 870x515x614 205 GFK 4DS 910x530x600 request MPL 4DS 1515x530x600 request MPL 4DS

Panda25i 0-20,0 25,0 0-20,0 25,0 - - ±3 V Kubota V1505 1498 4 request request request GFK 4DS request request MPL 4DS request request MPL 4DS

Panda45i - - 0-36,0 45,0 - - ±3 V Kubota V2403T 2434 4 request request request MPL 4DS 1442x660x880 662 MPL 4DS

Basic Line Generators - 3000 rpm - 50 Hz Panda Vehicle Generators without electronic regulation

Panda4,5ND 3,8 4,5 - - - - ±8% Farymann 18W430 298 1 54/64/68 765x450x560 161 GFK 4DS 800x440x570 195 MPL 4DS request request MPL 4DS

Premium Line Panda NE Generators - 3000 rpm - 50 Hz Panda Vehicle Generators with VCS Voltage Control System

Panda8000 6,8 8,0 6,8 8,0 6,0 6,0 ±3 V Kubota Z482 479 2 52/62/67 870x515x634 230 GFK 4DS 870x523x580 279 MPL 4DS 1330x522x620 352 MPL 4DS

Panda10000 8,0 9,4 8,0 9,4 7,0 7,0 ±3 V Kubota Z602 599 2 52/62/67 910x515x630 235 GFK 4DS request request MPL 4DS 1516x522x620 375 MPL 4DS

Panda12000 10,2 12,0 10,2 12,0 9,0 9,0 ±3 V Kubota D722 719 3 53/63/67 950x515x629 253 GFK 4DS 960x530x625 317 MPL 4DS 1566x530x625 411 MPL 4DS

Panda15000 12,7 15,0 12,7 15,0 11,1 11,1 ±3 V Kubota D902 898 3 54/64/68 1000x515x634 298 GFK 4DS 1000x530x630 377 MPL 4DS 1606x522x630 436 MPL 4DS

Panda18 15,3 18,0 15,3 18,0 13,5 13,5 ±3 V Kubota D1105 1123 3 55/65/69 1100x540x680 415 MPL 4DS 1100x560x680 440 MPL 4DS 1736x560x680 544 MPL 4DS

Panda 24 20,4 24,0 20,4 24,0 18,0 18,0 ±3 V Kubota V1505 1498 4 55/65/69 1220x540x680 465 MPL 4DS 1225x542x684 492 MPL 4DS 1854x542x684 492 MPL 4DS

Panda30 25,5 30,0 25,5 30,0 22,4 22,4 ±3 V Kubota V1505T 1498 4 55/65/69 1270x570x700 512 MPL 4DS 1270x570x690 530 MPL 4DS 1970x564x640 687 MPL 4DS

Panda40 - - 37,0 43,5 - - ±3 V Lombardini LDW2204T 2199 4 57/61/71 1405x690x780 765 MPL 4DS request request MPL 4DS request request MPL 4DS request request MPL 4DS

Panda60 - - 51,0 60,0 - - ±3 V Merc.Benz OM602A 2874 5 58/68/72 1665x730x810 933 MPL 4DS request request MPL 6DS request request MPL 6DS

Panda75 - - 63,7 75,0 - - ±3 V Merc.Benz OM603A3.5 3500 6 58/68/72 1845x730x830 1100 MPL 4DS request request MPL 6DS request request MPL 6DS

Panda100 - - 85,0 100,0 - - ±3 V Merc.Benz OM603A3.5 3500 6 58/68/72 1720x780x860 1150 MPL 4DS request request MPL 6DS request request MPL 6DS

Panda HD - 1500 rpm - 50 Hz Panda Vehicle Heavy Duty Generators with VCS Voltage Control System

Panda7,5-4 6,5 7,6 6,5 7,6 - - ±3 V Kubota D1105 1123 3 52/62/66 1055x515x665 338 GFK 4DS request request MPL 4DS request request MPL 4DS

Panda9-4 8,0 9,4 8,0 9,4 - - ±3 V Kubota D1105 1123 3 52/62/66 1140x730x700 389 MPL 4DS 1100x560x680 544 MPL 4DS request request MPL 4DS

Panda12-4 10,5 12,3 10,5 12,3 - - ±3 V Kubota V1505 1647 3 52/62/66 1170x540x 700 435 MPL 4DS request request MPL 4DS request request MPL 4DS

Panda17-4 14,7 17,5 14,7 17,5 - - ±3 V Kubota V2203 2197 4 53/63/67 1300x620x800 581 MPL 4DS request request MPL 4DS request request MPL 4DS

Panda22-4 18,6 21,9 18,6 21,9 - - ±3 V Kubota V2403 2434 4 53/63/67 1390x730x770 643 MPL 4DS 1390x600x760 643 MPL 4DS request request MPL 4DS

Panda30-4 25,0 29,4 25,0 29,4 - - ±3 V Mitsubishi MIS4S 3331 4 request 1473x690x890 800 MPL 4DS request request MPL 4DS request request MPL 4DS

Panda40-4 - - 35,0 41,1 - - ±3 V Mitsubishi MIS4SDT 3331 4 request 1560x710x950 867 MPL 4DS request request MPL 4DS request request MPL 4DS

Panda50-4 - - 40,0 47,0 - - ±3 V JCB NA-47 4399 4 request 1581x730x980 891 MPL 4DS request request MPL 4DS request request MPL 4DS

Panda60-4 - - 50,0 59,0 - - ±3 V Deutz BF4M2012C 4040 4 request 1885x790x1000 1298 MPL 6DS request request MPL 6DS request request MPL 6DS

Panda70-4 - - 61,0 72,0 - - ±3 V Deutz BF4M1013E 4764 4 request request request MPL 6DS request request MPL 6DS request request MPL 6DS

Panda85-4 - - 73,0 86,0 - - ±3 V Deutz BF4M1013EC 4764 4 request request request MPL 6DS request request MPL 6DS request request MPL 6DS

Panda110-4 - - 92,0 109,0 - - ±3 V Deutz BF6M1013E 7146 6 request request request MPL 6DS request request MPL 6DS request request MPL 6DS

Panda130-4 - - 111,0 130,0 - - ±3 V Deutz BF6M1013EC 7146 6 request request request MPL 6DS request request MPL 6DS request request MPL 6DS

Panda200-4 170,0 200,0 ±3 V Deutz BF6M1015E 11910 6 request request request MPL 6DS request request MPL 6DS request request MPL 6DS

Hybrid Power / Panda AGT-DDC Battery Charging Generators with VCS Voltage Control System

PandaGenerator

Model / Type AGTGeneratorwithsoundinsulationcapsule N

ominal

Perf

orm

ance

(kW)

Conti

nuou

sPe

rfor

man

ce

(kW)

Nom

inalvoltage

(DC)

Cons

tant

cur

rent

rate(A

)

Engi

ne R

evol

u-tio

ns

Volta

ge

Tole

ranc

e

Engi

neM

anuf

actu

ter

Engi

ne T

ype

Disp

lace

men

t cm

3

No.ofC

ylinde

rs

Soun

dLevel

[dBA

] (7

m/3m

/1m

) Approx.Capsule

Dimensions

(excl.fittings)

LxWxH(mm) Weigh

tincl.

Capsule(kg)

Stan

dardCap

sule

Type

Stan

dardSou

nd

Insulatio

n

Approx.Capsule

Dimensions

(excl.fittings)

LxWxH(mm) Weigh

tincl.

Capsule(kg)

Stan

dardCap

sule

Type

Stan

dardSou

nd

Insulatio

n

Approx.Capsule

Dimensions

(excl.fittings)

LxWxH(mm) Weigh

tincl.

Capsule(kg)

Stan

dardCap

sule

Type

Stan

dardSou

nd

Insulatio

n

Approx.Capsule

Dimensions

(excl.fittings)

LxWxH(mm) Weigh

tincl.

Capsule(kg)

Stan

dardCap

sule

Type

Stan

dardSou

nd

Insulatio

n

AGT-DC4000-12V 4 3,2 12 220 2400-3000 ±3 V Kubota EA300 309 1 55/65/69 770x450x430 120 GFK 4DS request request MPL 4DS 1210x450x440 148 MPL 4DS

AGT-DC4000-24V 4 3,2 24 110 2400-3000 ±3 V Kubota EA300 309 1 52/62/67 770x450x430 120 GFK 4DS request request MPL 4DS 1210x450x440 148 MPL 4DS

AGT-DC5000-12V 4,5 3,6 12 250 1800-2200 ±3 V Kubota Z482 479 2 52/62/67 750x505x615 189 GFK 4DS request request MPL 4DS request request MPL 4DS

AGT-DC6000-24V 5,5 4,8 24 170 2400-3200 ±3 V Kubota Z482 479 2 52/62/67 760x515x609 189 GFK 4DS request request MPL 4DS request request MPL 4DS

AGT-DC8000-24V 8 6,4 24 220 2200-2600 ±3 V Kubota D722 719 3 53/63/67 860x515x614 216 GFK 4DS request request MPL 4DS request request MPL 4DS

AGT-DC12000 12 request request ±3 V Kubota D902 898 3 54/64/68 request request GFK 4DS request request MPL 4DS request request MPL 4DS

AGT-DC14000 14 request request ±3 V Kubota D1105 1123 3 55/65/69 request request GFK 4DS request request MPL 4DS request request MPL 4DS

AGT-DC16000 16 request request ±3 V Kubota V1505 1498 4 55/65/69 1100x550x690 366 MPL 4DS request request MPL 4DS request request MPL 4DS

AGT-DC25000 25 request request ±3 V Kubota V1505T 1498 4 55/65/69 request request MPL 4DS request request MPL 4DS request request MPL 4DS

AGT-DC28000 28 request request ±3 V Kubota V2403 2434 4 55/65/69 request request MPL 4DS request request MPL 4DS request request MPL 4DS

18

CompleteProgramme-RadiatorOptions

Radiator Model

ApproximateDimensions

(L x W x H) mm Radi

ator

W

eigh

t (dr

y) k

g

Pand

a 4,

5 N

D

Pand

a 50

00i

Pand

a 80

00i

Pand

a 10

000i

Pand

a 15

000i

Pand

a 80

00

Pand

a 10

000

Pand

a 12

000

Pand

a 15

000

Pand

a 18

Pand

a 24

Pand

a 30

Pand

a 40

Pand

a 60

Pand

a 75

Pand

a 10

0

Pand

a 7,

5-4

Pand

a 9-

4

Pand

a 12

-4

Pand

a 17

-4

Pand

a 22

-4

Pand

a 30

-4

Pand

a 40

-4

Pand

a 50

-4

Pand

a 60

-4

Pand

a 70

-4

Pand

a 85

-4

Pand

a 11

0-4

Pand

a 13

0-4

Pand

a 20

0-4

AGT-

DC

400

0-12

V

AGT-

DC

400

0-24

V

AGT-

DC

500

0-12

V

AGT-

DC

600

0-24

V

AGT-

DC

800

0-24

V

AGT-

DC

120

00

AGT-

DC

140

00

AGT-

DC

160

00

AGT-

DC

250

00

AGT-

DC

280

00

RD-D: DC Roof mounted radiators RD-D: DC Roof mounted radiators

RD 1.2 705 x 390 x 310 18 x x x x

RD 2.2 930 x 515 x 321 29 x x x x x x x

RD 3.2 1050 x 515 x 321 32 x x x x x x x

RD 3.2 Trop 1055 x 515 x 361 40 x x x x

RD-A: AC Roof mounted radiators RD-A: AC Roof mounted radiators

RD3.3 - S350 1055 x 515 x 344 36 x x x x x x x x x x x x

RD3.3 Trop - S350 1055 x 515 x 393 42 x x x x x x x x x x

RD4.2 - FE040 735 x 705 x 373 32 x x x x x x x x x x x x x x

RD16.2 - 2xFE040 1040 x 630 x 358 56 x x x x x x

RD6/2.2 - 2xFE045 1405 x 630 x 401 67 x x x

RD7.2 - FE071 858 x 940 x 502 x x

RD8.2 - FE063 1100 x 1080 x 537 x x

RD P75 MB - 2xFE056 1960 x 990 x 531 x request

RD P75 MB - FE080 on request x request

RD P100 MB - 2xFE056 on request x request

RV-D: Side-/underneath (chassis mounted) radiators DC RV-D: Side-/underneath (chassis mounted) radiators DC

RV1.2 620 x 330 x 214 13 x x x x x x

RV2.2 750 x 450 x 224 21 x x x x x x

RV3.2 880 x 450 x 224 24 x x x x x x

RV3.2 Trop 920 x 450 x 254 30 x x x x x x

RV-A: Side mounted Radiators AC RV-A: Side mounted Radiators AC

RV 3.3 -S350 918 x 450 x 254 30 x x x x x x x x x x x x

RV 3.3 Trop - S350 920 x 450 x 288 33 x x x x x x x x x

RV 5.2 - FE040 580 x 610 x 356 32 x x x x x x x x x x x x x

RV 13.160 - FE050 600 x 719 x 436 52 x x x x x x

RV 6/2.2 - 2xFE045 1280 x 550 x 291 x x x

RV 14.120 - FE056 690 x 780 x 380 48 x x x x x

RV 14.160 - FE056 690 x 780 x 432 55 x x request

RV 7.2 - FE071 800 x 1000 x 416 63 x x request

RV 8.2 - FE063 1012 x 1100 x 396 78 x x request

RV P75 MB - 2xFE056 1900 x 1070 x 421 x

RV P75 MB - FE080 1270 x 1100 x 455 x

RV P100 MB - 2xFE056 on request x

19

Expansion Tank

Fan Controller

RD1.2

RD2.2

RV3.2

RD6/2.2

RV13.160

Radiator Model

ApproximateDimensions

(L x W x H) mm Radi

ator

W

eigh

t (dr

y) k

g

Pand

a 4,

5 N

D

Pand

a 50

00i

Pand

a 80

00i

Pand

a 10

000i

Pand

a 15

000i

Pand

a 80

00

Pand

a 10

000

Pand

a 12

000

Pand

a 15

000

Pand

a 18

Pand

a 24

Pand

a 30

Pand

a 40

Pand

a 60

Pand

a 75

Pand

a 10

0

Pand

a 7,

5-4

Pand

a 9-

4

Pand

a 12

-4

Pand

a 17

-4

Pand

a 22

-4

Pand

a 30

-4

Pand

a 40

-4

Pand

a 50

-4

Pand

a 60

-4

Pand

a 70

-4

Pand

a 85

-4

Pand

a 11

0-4

Pand

a 13

0-4

Pand

a 20

0-4

AGT-

DC

400

0-12

V

AGT-

DC

400

0-24

V

AGT-

DC

500

0-12

V

AGT-

DC

600

0-24

V

AGT-

DC

800

0-24

V

AGT-

DC

120

00

AGT-

DC

140

00

AGT-

DC

160

00

AGT-

DC

250

00

AGT-

DC

280

00

RD-D: DC Roof mounted radiators RD-D: DC Roof mounted radiators

RD 1.2 705 x 390 x 310 18 x x x x

RD 2.2 930 x 515 x 321 29 x x x x x x x

RD 3.2 1050 x 515 x 321 32 x x x x x x x

RD 3.2 Trop 1055 x 515 x 361 40 x x x x

RD-A: AC Roof mounted radiators RD-A: AC Roof mounted radiators

RD3.3 - S350 1055 x 515 x 344 36 x x x x x x x x x x x x

RD3.3 Trop - S350 1055 x 515 x 393 42 x x x x x x x x x x

RD4.2 - FE040 735 x 705 x 373 32 x x x x x x x x x x x x x x

RD16.2 - 2xFE040 1040 x 630 x 358 56 x x x x x x

RD6/2.2 - 2xFE045 1405 x 630 x 401 67 x x x

RD7.2 - FE071 858 x 940 x 502 x x

RD8.2 - FE063 1100 x 1080 x 537 x x

RD P75 MB - 2xFE056 1960 x 990 x 531 x request

RD P75 MB - FE080 on request x request

RD P100 MB - 2xFE056 on request x request

RV-D: Side-/underneath (chassis mounted) radiators DC RV-D: Side-/underneath (chassis mounted) radiators DC

RV1.2 620 x 330 x 214 13 x x x x x x

RV2.2 750 x 450 x 224 21 x x x x x x

RV3.2 880 x 450 x 224 24 x x x x x x

RV3.2 Trop 920 x 450 x 254 30 x x x x x x

RV-A: Side mounted Radiators AC RV-A: Side mounted Radiators AC

RV 3.3 -S350 918 x 450 x 254 30 x x x x x x x x x x x x

RV 3.3 Trop - S350 920 x 450 x 288 33 x x x x x x x x x

RV 5.2 - FE040 580 x 610 x 356 32 x x x x x x x x x x x x x

RV 13.160 - FE050 600 x 719 x 436 52 x x x x x x

RV 6/2.2 - 2xFE045 1280 x 550 x 291 x x x

RV 14.120 - FE056 690 x 780 x 380 48 x x x x x

RV 14.160 - FE056 690 x 780 x 432 55 x x request

RV 7.2 - FE071 800 x 1000 x 416 63 x x request

RV 8.2 - FE063 1012 x 1100 x 396 78 x x request

RV P75 MB - 2xFE056 1900 x 1070 x 421 x

RV P75 MB - FE080 1270 x 1100 x 455 x

RV P100 MB - 2xFE056 on request x

20

Power for Rail and Locomotive

Generators for Railway Applications

FischerPandaGeneratorsareinstalledonavarietyofrailwayapplicationsprovidingbatterychargingforthelocomotives,poweringequipmentusedbymaintenancewagonsorsupplyingpowertoaccommodationcarriages.

Generatorsprovidepowertoeachoffouraccommodationcarriages on board the luxury Danube Express, supplying electricalsystemsforair-conditioning,ensuiteshowersandcabinlighting.Thequietsupplyofpowerisalsoofimportanceduringovernightstopsincitiesthatrestricttheoperationoflocomotiveenginesatnightbecauseofnoiselevels.

Thegeneratorsarealsousedasauxiliarypowersourcessupplyingpowerfortasksthatwouldusuallybedrivenbyidlingthelocomotive’senginesuchascabinheatingorpreventingcoolingsystemsfromfreezinginwinterweather.ACgeneratorsarealsousedonmaintenancewagonstopowertools,compressors,pumpsandfloodlightingduringtrackrepair&replacement.

Thegenerator’slowprofileisidealformountingexternallyunderneaththewagon.Theheavy-dutysoundshieldprovidesadditionalprotectionifthegeneratorisinstalledexternally.

Radiatormountedseparatelyonwagonroof

Auxiliarypowerandcharging Maintenancewagonequipment Accommodationcarriagesystems

ExternalFischerPandaDCGeneratorwithside-mountedradiator.

21

Power for Isolated & Unmanned Applications

Ideal for remote communication and monitoring

Fischer Panda generators are ideal for remote communicationandmonitoringsites.Theircompactandrobustdesignmakesthemsuitableforoperatinginremoteareasandexposedlocations.Thesesitesareoftenunmannedandoperateforprolongedperiods,requiringonlyroutinemaintenanceschedulesandrefueling.

FischerPandaHybrid-DCgeneratorsprovidepowerfulbatterychargingcapabilitiesandcanbeintegratedwithwindandsolar-basedsystems.Thegeneratorstartsandstopsautomaticallywhenthebatterybanksrequirerecharging.

FischerPandaACgeneratorsareespeciallysuitedforapplicationswhichrequireevenmorecontinuouspowersuchasprovidingextracoverageatlargeevents.TheiSeriesgeneratorswithiControlaredesignedtoallowlongerperiodsbetweenmaintenancescheduleswhenoperatingwithlowerloads.

Optionsandservicesareavailabletomeetindividualspecificationsandrequirements.Thegeneratorsaredesignedtobeconnectedtoanexternalfuelsourcewithinacontainer-basedsystem.Generatorswithintegratedfueltankandelectricaldistributionareavailableonrequest.

This12kWPanda,insideamobileGSMstationfromCzechcompanyMeicoSystems,carriedout24-houroperationalperiodsforoveroneandahalfyears.Theunitoperatedformorethan19,960hours;stoppingonlyforroutineservicingandminorrepairs.

Evenwhentheunitiscompletelysubmergedunderdriftingsnow,theraisedexhaustandairintakesallowthegeneratortocontinueoperating.

Fullyautomaticoperationandmonitoring Extremely long service interval (up to 1500 hours) HybridSystems:combinewithbattery,solarandwindpower

22

Power for Off-Grid Buildings

Energy for Mountain Hostels and Weekend Homes

FischerPandageneratorsareidealforsupplyingpowertooff-gridorremotelylocatedbuildingssuchasmountainhostels,weekendhomesorevenalpinehuts.Thegenerator’slowspacerequirementsandcompactconstructionissuitedtothesebuildingswherespaceislimited.Effectivesoundshieldingreducesoperatingnoiseandlowvibrations.Thegeneratoriseasytooperateusingapanelwhichalsofeaturesanautomaticstart.

Powerisavailableforlargerconsumersincludingelectriccooking,boilersandevenair-conditioning.Guestscanalsoenjoythecomfortofbeingabletousedomesticconsumerappliancessuchashairdryersandcoffeemakers.

ThegeneratorcanalsobeusedtoformaneffectiveCombinedHeatandPowersystem(CHP)systemthatuses heat from the exhaust and radiator to supply the water-heatingsystemwhilethegeneratorisrunning.Thesystem’soverallefficiencyisincreased.Fuelsupplymaybeanimportantfactorinremotelocations.Optionsforusingalternativefuelsareavailableonrequest.Ahigherdegreeofefficiencycanbeachievedifusedinahybridsystemwithbattery,solarandwindpower.

Power for off-grid and remote buildings Co-generation (electric power and heating) Hybrid Systems: combine with battery, solar and wind power

Thisthree-phasePandaisinstalledinthebasement.Mainfuses,panel,andradiatorcontrolarefittedinelectricalcabinet.Image:KratosKft.Hungary.

Co-generation:Overallefficiencyisincreasedwhenexcess heat fromengine(exhaustandcooling)isalsousedtoheatwaterwhenelectricalenergyisgenerated.

23

Power for Utility-Connected Homes

iSeries BHKWs with Inverter Technology

ThenewiSeriesBHKWs(CombinedHeatingandPowerUnits)arethelatestrangeofcompact,quietandpowerfulFischerPandageneratorsdesignedforco-generationapplications.Theseofferbothfeed-in(supplyingunusedenergyinthegrid)andislanding(forbackupoperationsorapplicationswithoutgridconnection).

Utilizingtheindependent(variable)operatingspeedoftheengine,gridsupplyisachievedbyusinginvertertechnology.Electricalgridsaresuppliedbysolarphotovoltaic(PV)installationsinthesameway.

Typically,mostco-generationunitswithoutinvertertechnologyusefixed-speedengines.Thesearesettooperateeitherat3000rpm(2-pole)or1500rpm(4-pole)whereasthespeedoftheFischerPandaiSeriesBHKWscanvaryandoutputoptimallymatchedtotheengine.

Ifthegridfails,an“IslandingInverter”isoptionallyavailablethatsecuresthesupplyforcontinuousoperation.Thisprovides greater safety and independence from grid failure coupledwiththelatestgridfeedtechnology.

Increase supply safety with “Islanding” option Grid-feeding capabilities Alternative fuels available on request

Fischer Panda GmbHOtto-Hahn-Str. 40D-33104 PaderbornGermany

Tel. : +49 (0)5254 9202-0Fax : +49 (0)5254 9202-550Email : [email protected] : www.fischerpanda.de

Disclaimer:Theinformationcontainedhereistothebestofourknowledgeaccurateatthedateofpublication.Pleasenotethatthedatainthispublicationreflectsthetechnicalstateattimeofprint.Dimensionsapplyforthesoundinsulationcapsuleonlyanddonotincludelatches,fittings,etc.Additionalroomwillneedtobecalculatedforinstallationtoincludehoses,cablesandcapsulemountings.Additionalcomponentsoralternatorsmayalsoaffectcapsuledimensions.Duetoourpolicyofcontinualproductdevelopment,wereservetherighttoaltertechnicalspecificationswithoutnotice.Allperformancedatarelatestoairandwatertemperaturesof20°C.Performancereduction(approx.1%per100mheightandapprox2%per5°Cairtemperatureandapprox.1%per1°Cwatertemperatureabove20°C)

Stand:2014-09-18Art.71.02.01.06H