veneers preparation using m r dimashkieh self limiting bur

25
M R Dimashkieh Gauged Diamond V eneer preparaon

Upload: rida-dimashkieh

Post on 08-Jan-2017

186 views

Category:

Healthcare


1 download

TRANSCRIPT

Page 1: Veneers preparation using M R Dimashkieh self limiting bur

M R Dimashkieh Gauged Diamond Veneer preparation ���

Page 2: Veneers preparation using M R Dimashkieh self limiting bur

Dimashkieh,M.R.(1993).ModifiedrotarydesigninstrumentsforcontrolledfinishlinecrownpreparaAon.TheJournalofprosthe0cden0stry,69(1),120-121.

Page 3: Veneers preparation using M R Dimashkieh self limiting bur

Create the cervical margin first with controlled reduction parallel to the gingival half of the facial surface

Dimashkieh,M.R.(1993).ModifiedrotarydesigninstrumentsforcontrolledfinishlinecrownpreparaAon.TheJournalofprosthe0cden0stry,69(1),120-121.

Page 4: Veneers preparation using M R Dimashkieh self limiting bur

Dimashkieh,M.R.(1993).ModifiedrotarydesigninstrumentsforcontrolledfinishlinecrownpreparaAon.TheJournalofprosthe0cden0stry,69(1),120-121.

Create the cervical margin first with controlled reduction parallel to the gingival half of the facial surface

Page 5: Veneers preparation using M R Dimashkieh self limiting bur

Dimashkieh,M.R.(1993).ModifiedrotarydesigninstrumentsforcontrolledfinishlinecrownpreparaAon.TheJournalofprosthe0cden0stry,69(1),120-121.

Page 6: Veneers preparation using M R Dimashkieh self limiting bur

M R Dimashkieh

Create the second plane with controlled reduction parallel to the incisal half of the facial surface

Dimashkieh,M.R.(1993).ModifiedrotarydesigninstrumentsforcontrolledfinishlinecrownpreparaAon.TheJournalofprosthe0cden0stry,69(1),120-121.

Page 7: Veneers preparation using M R Dimashkieh self limiting bur

M R Dimashkieh

When M R Gauged Diamond reaches its full abrading depth the guiding pin will rest on the external tooth surface

Dimashkieh,M.R.(1993).ModifiedrotarydesigninstrumentsforcontrolledfinishlinecrownpreparaAon.TheJournalofprosthe0cden0stry,69(1),120-121.

Page 8: Veneers preparation using M R Dimashkieh self limiting bur

M R Dimashkieh

Dimashkieh,M.R.(1993).ModifiedrotarydesigninstrumentsforcontrolledfinishlinecrownpreparaAon.TheJournalofprosthe0cden0stry,69(1),120-121.

Page 9: Veneers preparation using M R Dimashkieh self limiting bur

M R Dimashkieh

Dimashkieh,M.R.(1993).ModifiedrotarydesigninstrumentsforcontrolledfinishlinecrownpreparaAon.TheJournalofprosthe0cden0stry,69(1),120-121.

Page 10: Veneers preparation using M R Dimashkieh self limiting bur

M R Dimashkieh

Dimashkieh,M.R.(1993).ModifiedrotarydesigninstrumentsforcontrolledfinishlinecrownpreparaAon.TheJournalofprosthe0cden0stry,69(1),120-121.

Page 11: Veneers preparation using M R Dimashkieh self limiting bur

M R Dimashkieh

Dimashkieh,M.R.(1993).ModifiedrotarydesigninstrumentsforcontrolledfinishlinecrownpreparaAon.TheJournalofprosthe0cden0stry,69(1),120-121.

Page 12: Veneers preparation using M R Dimashkieh self limiting bur

M R Dimashkieh

Dimashkieh,M.R.(1993).ModifiedrotarydesigninstrumentsforcontrolledfinishlinecrownpreparaAon.TheJournalofprosthe0cden0stry,69(1),120-121.

Page 13: Veneers preparation using M R Dimashkieh self limiting bur

M R Dimashkieh

Page 14: Veneers preparation using M R Dimashkieh self limiting bur
Page 15: Veneers preparation using M R Dimashkieh self limiting bur

M R Dimashkieh

Dimashkieh,M.R.(1993).ModifiedrotarydesigninstrumentsforcontrolledfinishlinecrownpreparaAon.TheJournalofprosthe0cden0stry,69(1),120-121.

Page 16: Veneers preparation using M R Dimashkieh self limiting bur

M R Dimashkieh

If the finish line required to be sub-gingival move the rotating diamond toward the gingiva while the pin is kept in contact with the external tooth surface

Dimashkieh,M.R.(1993).ModifiedrotarydesigninstrumentsforcontrolledfinishlinecrownpreparaAon.TheJournalofprosthe0cden0stry,69(1),120-121.

Page 17: Veneers preparation using M R Dimashkieh self limiting bur

M R Dimashkieh

Dimashkieh,M.R.(1993).ModifiedrotarydesigninstrumentsforcontrolledfinishlinecrownpreparaAon.TheJournalofprosthe0cden0stry,69(1),120-121.

Page 18: Veneers preparation using M R Dimashkieh self limiting bur

M R Dimashkieh

The guiding pin can enter into the gingival sulcus up to 1.0 mm

Dimashkieh,M.R.(1993).ModifiedrotarydesigninstrumentsforcontrolledfinishlinecrownpreparaAon.TheJournalofprosthe0cden0stry,69(1),120-121.

Page 19: Veneers preparation using M R Dimashkieh self limiting bur

M R Dimashkieh

Dimashkieh,M.R.(1993).ModifiedrotarydesigninstrumentsforcontrolledfinishlinecrownpreparaAon.TheJournalofprosthe0cden0stry,69(1),120-121.

Page 20: Veneers preparation using M R Dimashkieh self limiting bur

M R Dimashkieh

Dimashkieh,M.R.(1993).ModifiedrotarydesigninstrumentsforcontrolledfinishlinecrownpreparaAon.TheJournalofprosthe0cden0stry,69(1),120-121.

Page 21: Veneers preparation using M R Dimashkieh self limiting bur

M R Dimashkieh

Dimashkieh,M.R.(1993).ModifiedrotarydesigninstrumentsforcontrolledfinishlinecrownpreparaAon.TheJournalofprosthe0cden0stry,69(1),120-121.

Page 22: Veneers preparation using M R Dimashkieh self limiting bur

M R Dimashkieh

Dimashkieh,M.R.(1993).ModifiedrotarydesigninstrumentsforcontrolledfinishlinecrownpreparaAon.TheJournalofprosthe0cden0stry,69(1),120-121.

Page 23: Veneers preparation using M R Dimashkieh self limiting bur

M R Dimashkieh

The guiding pin can enter into the gingival sulcus up to 1.0 mm

Remember, Guiding pin should not rest on external gingival surface during preparation at all time

Page 24: Veneers preparation using M R Dimashkieh self limiting bur

Provided with 2 Sizes 0.7 mm – 0.5 mm

Different combination of diamond sizes and step back produce different depth of finish lines as required: 0.5 + 0.5 = 1 mm 0.5 + 0.7 = 1.2 mm 0.7 + 0.7 = 1.4 mm

Dimashkieh,M.R.(1993).ModifiedrotarydesigninstrumentsforcontrolledfinishlinecrownpreparaAon.TheJournalofprosthe0cden0stry,69(1),120-121.

Page 25: Veneers preparation using M R Dimashkieh self limiting bur

References:

1.  Dimashkieh, M. R. (1993). Modified rotary design instruments for controlled finish line crown preparation. The Journal of prosthetic dentistry, 69(1), 120-121.

2.  Boening, K. W., Kaestner, K. I., Luthardt, R. G., & Walter,

M. H. (2001). Burs with guide pins for standardized tooth preparation. Quintessence International, 32(3).

3.  https://www.researchgate.net/profile/Reda_Dimashkieh