Page 1: Venting & Inspection€¦ · SEPTIC TANK 30 A-Center-to-center pipe spacing C-Minimum separation distance F.G.-Fina1 grade O.G.-Original grade W-Width of Enviro-Septic pipe SYSTEM

Venting & Inspection

Page 2: Venting & Inspection€¦ · SEPTIC TANK 30 A-Center-to-center pipe spacing C-Minimum separation distance F.G.-Fina1 grade O.G.-Original grade W-Width of Enviro-Septic pipe SYSTEM

Differential Venting• Entry vent is at the end of the system

• Exit vent is on the roof of the building

• A minimum difference of 10’ is needed

• If a pumping station is used, install an air bypass pipe

Page 3: Venting & Inspection€¦ · SEPTIC TANK 30 A-Center-to-center pipe spacing C-Minimum separation distance F.G.-Fina1 grade O.G.-Original grade W-Width of Enviro-Septic pipe SYSTEM
Page 4: Venting & Inspection€¦ · SEPTIC TANK 30 A-Center-to-center pipe spacing C-Minimum separation distance F.G.-Fina1 grade O.G.-Original grade W-Width of Enviro-Septic pipe SYSTEM

EnviroSepticTM

Design Considerations /

Calculations

Page 5: Venting & Inspection€¦ · SEPTIC TANK 30 A-Center-to-center pipe spacing C-Minimum separation distance F.G.-Fina1 grade O.G.-Original grade W-Width of Enviro-Septic pipe SYSTEM

Minimum # of Pipes = Peak Flow / 27.7 Imp. Gal (126 L)

Required Dispersal Area = Peak Flow / Infiltrative Loading Rate

Required System Sand = 12” (30cm) below AES Pipes

6” (15cm) on either side of AES Pipes

4” (10cm) above AES Pipes

Minimum Lateral Length = 20 Feet (2 Pipes)Maximum Lateral Length = 60 Feet (6 Pipes)

Treatment Capacity is the same regardless of whether it is front end

fed or Centre Fed; however, it is possible to Linear Load based on

the HLLR in Appendix A.1.E.1.

Page 6: Venting & Inspection€¦ · SEPTIC TANK 30 A-Center-to-center pipe spacing C-Minimum separation distance F.G.-Fina1 grade O.G.-Original grade W-Width of Enviro-Septic pipe SYSTEM

EnviroSepticTM

System Configurations

Page 7: Venting & Inspection€¦ · SEPTIC TANK 30 A-Center-to-center pipe spacing C-Minimum separation distance F.G.-Fina1 grade O.G.-Original grade W-Width of Enviro-Septic pipe SYSTEM

Trench System

Page 8: Venting & Inspection€¦ · SEPTIC TANK 30 A-Center-to-center pipe spacing C-Minimum separation distance F.G.-Fina1 grade O.G.-Original grade W-Width of Enviro-Septic pipe SYSTEM

Subsurface Installation

Page 9: Venting & Inspection€¦ · SEPTIC TANK 30 A-Center-to-center pipe spacing C-Minimum separation distance F.G.-Fina1 grade O.G.-Original grade W-Width of Enviro-Septic pipe SYSTEM

Above Ground

Page 10: Venting & Inspection€¦ · SEPTIC TANK 30 A-Center-to-center pipe spacing C-Minimum separation distance F.G.-Fina1 grade O.G.-Original grade W-Width of Enviro-Septic pipe SYSTEM

Mound Installation

Page 11: Venting & Inspection€¦ · SEPTIC TANK 30 A-Center-to-center pipe spacing C-Minimum separation distance F.G.-Fina1 grade O.G.-Original grade W-Width of Enviro-Septic pipe SYSTEM

Raised Sloping System

Page 12: Venting & Inspection€¦ · SEPTIC TANK 30 A-Center-to-center pipe spacing C-Minimum separation distance F.G.-Fina1 grade O.G.-Original grade W-Width of Enviro-Septic pipe SYSTEM

Commercial System

Page 13: Venting & Inspection€¦ · SEPTIC TANK 30 A-Center-to-center pipe spacing C-Minimum separation distance F.G.-Fina1 grade O.G.-Original grade W-Width of Enviro-Septic pipe SYSTEM

Low Pressure Distribution System –

Alternating Lateral Dosing

Page 14: Venting & Inspection€¦ · SEPTIC TANK 30 A-Center-to-center pipe spacing C-Minimum separation distance F.G.-Fina1 grade O.G.-Original grade W-Width of Enviro-Septic pipe SYSTEM

Custom Configurations

Page 15: Venting & Inspection€¦ · SEPTIC TANK 30 A-Center-to-center pipe spacing C-Minimum separation distance F.G.-Fina1 grade O.G.-Original grade W-Width of Enviro-Septic pipe SYSTEM

Questions??