ver 1.1 2005.03 seÇÃo 6 revision history ajustesdiagramas.diagramasde.com/otros/dsc-t7 adj...

39
SEÇÃO 6 AJUSTES DSC-T7 Revision History Ver 1.1 2005.03 Link Before starting adjustments IItens de ajustes quando reparar as peças principais e as placas AJUSTES DO SEÇÃO DE CAMERA AJUSTES DO SISTEMA DE LCD ERROS AJUSTES DO SISTEMA DE VIDEO AJUSTES DO SISTEMA DE CAMERA PROGRAMAS PARA AJUSTES INICIALIZAÇÃO DE DADOS PREPARAÇÃO ANTES DE AJUSTES NOTA DE SERVÍÇO MODO DE SERVIÇO Sony EMCS Co. 9-876-879-51 Conteúdos dos Manuais de Serviço dos LEVEL 2 e LEVEL 3 CONTEÚDO 1. NOTA DE SERVIÇO 2. DESMONTAGEM 3. DIAGRAMAS EM BLOCOS 4. PLACA DE CIRCUITO IMPRESSO E DIAGRAMA ESQUEMÁTICO 5. LISTA DE PEÇAS LEVEL 2 a a GERAL POWER CD-541, MC-149, MS-258 PLACA SW-454 PLACA FLEXÍSIVEL UNIDADE DO FLASH CONTROLE DO BLOCK DE CHAVE (GP51710, RL51710) VISTA EXPLODIDA PARTES ELÉTRICAS LEVEL 3 SY-115 PLACA a (SY-115 PLACA) Use este Manual de Serviço junto com o Automatic Adjustment Program (DSC-T7 Auto-Adj Ver1.[]r [][].exe) e AWB Adjustment Program (T7AwbAdjustment.exe). Note: [] (valor numérico) do nome do arquivo varia dependendo da versão do Automatic Adjustment Program. Auto-ADJ 2005C0500-1 © 2005.7 Published by DI Technical Support Section - Traduzido por Sony Brasil Ltda.- Engenharia da Qualidade DSC-T7

Upload: others

Post on 24-Mar-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

SEÇÃO 6AJUSTES

DSC-T7Revision History

Ver 1.1 2005.03

Link

Before starting adjustments

IItens de ajustes quando reparar as peças principais e as placas

AJUSTES DO SEÇÃO DE CAMERA

AJUSTES DO SISTEMA DE LCD

ERROS

AJUSTES DO SISTEMA DE VIDEO

AJUSTES DO SISTEMA DE CAMERA

PROGRAMAS PARA AJUSTES

INICIALIZAÇÃO DE DADOS

PREPARAÇÃO ANTES DE AJUSTES

NOTA DE SERVÍÇO

MODO DE SERVIÇO

Sony EMCS Co.9-876-879-51

Conteúdos dos Manuais de Serviço dos LEVEL 2 e LEVEL 3 CONTEÚDO

1. NOTA DE SERVIÇO2. DESMONTAGEM3. DIAGRAMAS EM BLOCOS

4. PLACA DE CIRCUITO IMPRESSOE DIAGRAMA ESQUEMÁTICO

5. LISTA DE PEÇAS

LEVEL 2a

a

GERALPOWERCD-541, MC-149, MS-258 PLACASW-454 PLACA FLEXÍSIVELUNIDADE DO FLASHCONTROLE DO BLOCK DE CHAVE(GP51710, RL51710)VISTA EXPLODIDAPARTES ELÉTRICAS

LEVEL 3

SY-115 PLACA

a

(SY-115 PLACA)

• Use este Manual de Serviço junto com o Automatic Adjustment Program (DSC-T7 Auto-Adj Ver1.[]r [][].exe)e AWB Adjustment Program (T7AwbAdjustment.exe).

Note: [] (valor numérico) do nome do arquivo varia dependendo da versão do Automatic Adjustment Program.

Auto-ADJ

2005C0500-1© 2005.7

Published by DI Technical Support Section - Traduzido por Sony Brasil Ltda.- Engenharia da Qualidade

DSC-T7

— 2 —DSC-T7

ÍNDICESection Title Page

6. AJUSTESBefore Starting Adjustment ······················································· 6-11-1. Adjusting Items When Replacing

Main Parts and Boards ···················································· 6-26-1. Camera Section Adjustments ··········································· 6-31-1. Preparations Before Adjustments ···································· 6-31-1-1.List of Service Tools ························································ 6-31-1-2.Preparations ····································································· 6-41-1-3.Precautions ······································································ 6-51. Setting the Switch ···························································· 6-52. Subjects ··········································································· 6-53. Preparing the Flash Adjustment Box ······························· 6-61-1-4.Using Method of SEUS ··················································· 6-71. Connection ······································································· 6-72. Operation ········································································· 6-71-1-5.Precaution on Use of SEUS············································· 6-71-2. Adjustment Programs ······················································ 6-81-2-1.Automatic Adjustment Program ······································ 6-81. Precautions When Using Automatic Adjustment

Program ··········································································· 6-82. Start of Automatic Adjustment Program ························· 6-83. Function of Each Button on Main Menu Screen ············· 6-81-2-2.AWB Adjustment Program ·············································· 6-91. Application Environment ················································ 6-92. Installation Method ·························································· 6-93. Notes When Using the AWB Adjustment Program ········· 6-94. Starting Method of AWB Adjustment Program ··············· 6-95. Screen and Function of Each Button of

AWB Adjustment Program ·············································· 6-91-3. Video System Adjustments ············································ 6-101-3-1.Function of Each Button on Video System

Adjustment Screen ························································ 6-101-3-2.Adjustment Items of Video System Adjustment ············ 6-101-3-3.Adjusting Method ·························································· 6-111-4. Camera System Adjustments ········································· 6-121-4-1.Function of Each Button on Camera System

Adjustment Screen ························································ 6-121-4-2.Adjustment Items of Camera System Adjustment ········ 6-131-4-3.Adjusting Method ·························································· 6-141. Wide Limit Adjustment ················································· 6-141-1. Adjusting method when lens is replaced: ······················ 6-141-2. Adjusting method when replacement of lens is not

required and the SY-115 board is replaced: ··················· 6-142. Camera Adjustment 1 ···················································· 6-153. Camera Adjustment 2 ···················································· 6-164. Picture Frame Setting (Standard Picture Frame) ··········· 6-165. Camera Adjustment 3 ···················································· 6-176. AWB 3200K-5800K Standard Data Input ····················· 6-187. Camera Adjustment 4 ···················································· 6-198. Camera Adjustment 5 ···················································· 6-201-5. LCD System Adjustments ············································· 6-211-5-1.Function of Each Button on LCD System

Adjustment Screen ························································ 6-211-5-2.Adjustment Items of LCD System Adjustment ············· 6-211-5-3.Adjusting Method ·························································· 6-221-6. Error ··············································································· 6-231-6-1.Error Message ································································ 6-231. Connect Error ································································ 6-232. Reset the Camera and Try Again ··································· 6-233. Adjustment Time Out ···················································· 6-234. Adjustment NG······························································ 6-235. Data Save Error ····························································· 6-24

1-6-2.Precautions When an Error Occurred ···························· 6-241-7. Initialization of Data ······················································ 6-251. Initializing All Page Data ·············································· 6-252. Initializing Single Page Data ········································· 6-256-2. Service Mode ································································· 6-261. Setting the Test Mode ···················································· 6-262. Bit Value Discrimination ··············································· 6-263. LED Check ···································································· 6-274. Switch Check (1) ··························································· 6-275. Switch Check (2) ··························································· 6-286. Mode Switch Check ······················································ 6-287. Self Diagnosis Code ······················································ 6-28

Section Title Page

6-1DSC-T7

SEÇÃO 6AJUSTES

Antes de iniciar ajuste

(The same model of the same destination)

(Machine to be repaired)PC

After the EVR data is saved and downloaded, check therespective items of the EVR data.(Refer to page 6-2 for the items to be checked.)

EVR Data Re-writing Procedure When Replacing BoardThe data that is stored in the repair board, is not necessarily correct.Perform either procedure 1 or procedure 2 when replacing board.

PC

Procedure 2When the data cannot be saved due to defective flash memory, or when the flash memory cannot be removed orinstalled, save the data from the same model of the same destination, and download it.

PC

Save the EVR datato a personal computer.

Download the saveddata to a machine.

Procedure 1Save the EVR data of the machine in which a board is going to be replaced. Download the saved data after aboard is replaced.

(Machine after a board is replaced)(Machine before starting repair)

Download the data.

Save the data.

(Machine to be repaired)

6-2DSC-T7

1-1. Adjusting items when replacing main parts and boardsWhen replacing main parts and boards, adjust the items indicated by z in the following table.Note 1: The automatic Adjustment Program does not support the “Initialization of data” and “Wide Limit Adjustment”. Perform them

manually.Note 2: Use the AWB Adjustment Program (T7AwbAdjustment.exe).

Table 6-1-1

Replaced parts

Block Mounted parts Boardreplacement replacement replacement

Adjusting item Adjustment LC

D u

nit

Bac

k lig

ht u

nit

(Tim

ing

gen.

, CC

D s

igna

l pro

cess

)

(Vid

eo a

mp.

)

LC

D90

1

D90

1

IC10

1

IC35

0

(CO

MPL

ET

E)

Len

s bl

ock

(Inc

ludi

ng C

D-5

41 f

lexi

ble

boar

d (C

CD

imag

er))

Flas

h un

it

Con

trol

sw

itch

bloc

k (R

L51

710)

(A

F ill

umin

atio

n L

ED

)

LC

D b

lock

LC

D b

lock

SY-1

15 b

oard

SY-1

15 b

oard

SY-1

15 b

oard

(Note 1) Initialization of data z

VIDEO adjustment Video output level adj. z z

(Note 1) Wide limit adj. z z

CAMERA adjustment 1 Flange back adj. z z

CAMERA adjustment 2 Flange back check z z

F No. compensation

Measure gain adj.

Mechanical shutter adj.

Light value adj.

(Note 2) AWB 3200K-5800K standard data input z z z

Color reproduction adj. & check

CCD linearity check

CCD white defect compensation check

CCD black defect compensation check

Strobe adj.

Auto focus illumination check

COM AC adj.

V-COM adj.

White Balance adj.

LCD adjustment z z

z

z

CAMERA adjustment 5 z z z

CAMERA adjustment 4

CAMERA adjustment 3 z

z

z

z

z

z

z

6-3DSC-T7

6-1. AJUSTES DA SEÇÃO DE CAMERA

1-1. PREPARATIONS BEFORE ADJUSTMENTS1-1-1. List of Service Tools• Oscilloscope • Color monitor • AC power adapter

Fig. 6-1-1

Note1: Personal computerOS: Windows98/98SE/Me/2000/XP Home/XP ProRAM: 256MB or more recommendedUSB: 2.0 recommended (also compatible with 1.1)

Two connectors are required.Note2: In using the 9 colors chart on the pattern box PTB-450, adjust the chart size through the procedure shown below so that it

matches to the pattern box PTB-450.1) Prepare a woody board A of the thickness 5 mm, and paint it mat-black.2) Fit the 9 colors chart in the woody board A, and secure the chart with a black tape, etc. to shield the light.

Fig. 6-1-2

360 mm

155 mm

280 mm

woody boad Awoody boad A

9 colors chart

135 mm

Personal computer(Note 1)

J-1

J-10

J-9J-7

HASP key and application for adjustment (SEUS)

Contact our service headquater of each area how to get the application for adjustment (SEUS) and HASP key.

J-2

Pattern box PTB-450J-6082-200-A orSmall pattern boxPTB-1450J-6082-557-A

J-4Clear chart

For PTB-450:J-6080-621-A

For PTB-1450:J-6082-560-A

J-6

Minipattern boxJ-6082-353-B

Siemens star chartJ-6080-875-A

Back ground paperJ-2501-130-A

J-11Interface adaptor

US model:1-819-219-31

Except US model:1-819-219-11

J-12

StandX-2055-343-1

9 colors chart (Note 2)

For PTB-1450:J-6082-562-A

J-5

J-8

Flange backadjustment jigJ-6082-563-A

USB cable1-829-579-31

J-3

6-4DSC-T7

Fig. 6-1-4

1-1-2. Preparations1) Connect the equipment for adjustments according to Fig. 6-1-4.2) Start up the application for adjustment (SEUS).

Note: Before perform the adjustment, set the following data.1) Select page: 40, address: 38 and set data: 00.

Fig. 6-1-3

Front of the lens

Stand(X-2055-343-1)

L = About 11 cm

L

Pattern box

PC (The SEUS must be installed in the PC.)OS: Windows 98/98SE/Me/2000/XPRAM: 256MB or more recommendedUSB: 2.0 recommended (also compatible with 1.1) Two connectors are required.

Video system Adjustment

Osilloscope

Terminated75 Ω

AC IN

AC power adaptor

To USB connector

To AV OUT jack (Note)

Note: Do not connect the A/V cable when perfoming the LCD system adjustment.

HASP Key

To USB connector

To USB connector

USB cable(1-829-579-31)

Stand(X-2055-343-1)

Interface adaptor(US model: 1-819-219-31 Except US model: 1-819-219-11)

Audio (Black)

Video (yellow)

Color monitor

Insert the Memory Stick Duo.

6-5DSC-T7

1-1-3. Precautions1. Setting the SwitchUnless otherwise specified, set the switches as follows and per-form adjustments.1. Mode switch ....................................... CAMERA2. ZOOM lever ....................................... WIDE end3. Video Out (SET UP setting) .............. NTSC4. Digital Zoom (SET UP setting) ......... Off5. Camera (Menu items) ........................ Auto

2. Subjects1) 9 colors chart (Standard picture frame).

When performing adjustments using the 9 colors chart, adjustthe picture frame as shown in Fig. 6-1-5. (Standard pictureframe)

2) Clear chart (Standard picture frame)Remove the 9 colors chart from the pattern box and insert aclear chart in its place. (Do not perform zoom operations dur-ing this time)

Fig. 6-1-5

9 colors chart (Standard picture frame)

Adjust the camera position and directionto obtain the LCD screen or the monitorTV display shown in Fig. a.

Fig. a LCD screen or under scan monitor TV picture

A

C

C

Effective picture frame

White

Green Yellow W14

Red

Magenta

Cyan

Blue

B

C14

A2

B A

A = B

C14 : Filter for AWB 5800K adjustment

C =B3

Transparent window

6-6DSC-T7

3. Preparing the Flash Adjustment BoxA dark room is required to provide an accurate flash adjustment.If it is not available, prepare the flash adjustment box as givenbelow;

1) Provide woody board A, B and C of 15 mm thickness.

2) Apply black mat paint to one side of woody board A and B.3) Attach background paper (J-2501-130-A) to woody board C.4) Assemble so that the black sides and the background paper

side of woody board A, B and C are internal. (Fig. 6-1-7)

Fig. 6-1-6

Fig. 6-1-7

woody board A (2)

400 mm

woody board B (2)

370 mm

woody board C (1)

700 mm

513 mm 513 mm 700 mm

700 mm730 mm

woody board A

woody board B

woody board B

woody board C

woody board A

6-7DSC-T7

1-1-4. Using Method of SEUS

The application for adjustment (SEUS) is used to change the coef-ficient for calculating the signal processing or EVR data. The SEUSperforms two-way communication between PC and set throughthe USB terminal. The two-way communication result data can bewritten to the nonvolatile memory.

1. Connection1) Connect the HASP key to the USB terminal of the PC.2) Connect the PC and set with the USB cable.3) Confirm that the set starts in the USB mode.4) Start the SEUS on the PC.5) Click [Connect] on the SEUS screen. If the connection is nor-

mal, the SEUS screen will be as shown in Fig. 6-1-8, indicat-ing the “connected” state.Note: The SEUS will go in “disconnect" state, if the set is

turned off (for instance, by resetting the set). In such acase, click [Connect] on the SEUS screen to restorethe “connected” state.

2. Operation• Page change

To change the page, click [Page] on the SEUS screen and enterthe page to be changed. The page is displayed in hexadecimalnotation.

• Address changeTo change the address, click [Address] on the SEUS screen andenter the address to be changed. The address is displayed inhexadecimal notation.

• Data changeTo change the data, click [Set] on the SEUS screen and enterthe data. The data is displayed in hexadecimal notation.This operation does not write the data to the nonvolatile memory.

• Data savingTo write the all changed data to the nonvolatile memory, click[Save] on the SEUS screen and wait for more than 3 sec.

• Data readingThe data displayed on the SEUS screen are the data values atthe time when the pages and addresses were set, and they arenot updated automatically. To check the data change, click[Read] on the SEUS screen and update the displayed data.

1-1-5. Precaution on Use of SEUSWrong SEUS operation could clear correct adjustment data. Toprevent the data clear by mistake, it is recommended to save alladjustment data by clicking [Page Edit] on the SEUS screen be-fore starting the adjustment.

Saving Method:1) Click [Page Edit] on the SEUS screen to display the SEUS

PAGE EDIT screen.2) Click [Page], and enter the page number to be saved.3) Click [Page] to read the data to be saved from the camera.4) Click [File] and save the data to PC.

Loading Method:1) Select page: 00, address: 01 and set data: 01.2) Click [Page Edit] on the SEUS screen to display the SEUS

PAGE EDIT screen.3) Click [File] and load the data from PC.4) Click [Write] on the SEUS PAGE EDIT screen.5) Click [Close] to close the SEUS PAGE EDIT screen.6) Select page: 40, address: 38 and set data: 00.7) Click [Save] on the SEUS screen.8) Wait for more than 3 sec.9) Select page: 80, address: 30, and check that the data is “00”.10) Select page: 00, address: 01 and set data: 00.

Fig. 6-1-8

6-8DSC-T7

1-2. ADJUSTMENT PROGRAMS

The DSC-T7 is adjusted with the Automatic Adjustment Programand the AWB Adjustment Program.The Automatic Adjustment Program automatically controls theadjustment operations that were formerly entered manually on theoperation screen of the SEUS (some adjustments may be manu-ally operated on the SEUS operation screen).The AWB Adjustment Program automatically performs “AWB3200K-5800K Standard Data Input” of Camera System Adjust-ment.

1-2-1. Automatic Adjustment Program1. Precautions When Using Automatic Adjustment

Program1) The Automatic Adjustment Program writes the adjustment re-

sults such as EVR data to the set through two-way communi-cation with the camera via the SEUS. Accordingly, the Auto-matic Adjustment Program must be used in the environmentwhere the SEUS operates.

2) The program run time may vary depending on the environ-ment of the personal computer used.

3) Even if the Automatic Adjustment Program is used withoutstarting the SEUS, the SEUS will start automatically when theadjustment is executed. However, it may take time for the SEUSto start, and therefore the Automatic Adjustment Programshould be used with the SEUS started in order to reduce theprogram run time.

2. Start of Automatic Adjustment ProgramDouble-click the application file (DSC-T7 Auto-Adj Ver_1.[]r[][].exe),and the Automatic Adjustment Program will start.

Note: [] (numeric value) of the file name varies depending on theversion of Automatic Adjustment Program.

3. Function of Each Button on Main Menu ScreenWhen the Automatic Adjustment Program started, the Main Menuscreen in Fig. 6-1-9 will appear. On this screen, select each adjust-ment section.

Fig. 6-1-9

1 [Connecting the Equipment] buttonA connection diagram of the equipment is displayed.

2 [VIDEO SYSTEM ADJUSTMENT] buttonThe “VIDEO SYSTEM ADJUSTMENT” screen appears.

3 [CAMERA SYSTEM ADJUSTMENT] buttonThe “CAMERA SYSTEM ADJUSTMENT” screen appears.

4 [LCD SYSTEM ADJUSTMENT] buttonThe “LCD SYSTEM ADJUSTMENT” screen appears.

5 [END] buttonThe Automatic Adjustment Program finishes.

6 This part indicates the version of Automatic Adjustment Pro-gram.

5

3

2

1

4

6

6-9DSC-T7

1-2-2. AWB Adjustment Program1. Application EnvironmentOS: Windows 98/98SE/Me/2000/XPRAM: 256MB or more recommendedUSB: 2.0 recommended (also compatible with 1.1)

Two connectors are required.

2. Installation MethodExtract the file compressed in the ZIP format (T7AWBAdjustment.zip).Execute the extracted file (setup.exe), and the installer will start. In-stall the program following the instructions given on the installer screen.

3. Notes When Using the AWB Adjustment Program1) The SEUS must be installed in the PC.2) The HASP Key for SEUS must be connected to the USB con-

nector. The program will not start unless the HASP Key isconnected.

4. Starting Method of AWB Adjustment ProgramClick the [Start] button on the task bar, and click the [DSC-T7AWB Adjustment] from the [Programs], and the program willstart.

5. Screen and Function of Each Button of AWBAdjustment Program

Fig. 6-1-10

1 [Connect] buttonMakes connection to the camera and switches the camera tothe adjustment mode. In the case of successful connection tothe camera, the indication at the part A changes to “Connected”and the following buttons become active.• [AWB 3200K-5800K Standard Data Input] button• [Disconnect] button

2 Adjustment start buttonsStart the adjustment or checking of respective button names.

3 [Disconnect] buttonCancels the connection to the camera.

4 Captured picture display screenDisplays a picture captured by the camera when the adjust-ment or checking was performed.

4

3

2

1

A

6-10DSC-T7

1-3. VIDEO SYSTEM ADJUSTMENTS

1-3-1. Function of Each Button on Video SystemAdjustment Screen

Click the [VIDEO SYSTEM ADJUSTMENT] button on the MainMenu screen, and the “VIDEO SYSTEM ADJUSTMENT” screenin Fig. 6-1-11 will appear.

Fig. 6-1-11

1 [To Menu] buttonThe Main Menu screen comes back.

2 [Preparation] buttonNotes for adjustment or jigs usd are displayed.

3 [Start] button“Video Adjustment” starts.

4 [Reset] buttonThis button functions same as the “Initialize” of the setupscreen.

5 [Release Data Setting] buttonThe data setting at the adjustment is cancelled.During the data setting, the button color changes from “white”to “red”. When the data setting is cancelled, the button colorreturns to “white”.(Use this button when an error occurred in the video adjust-ment. If the adjustment completed successfully, the data set-ting is automatically cancelled and the button color returns to“white”.)

1-3-2. Adjustment Items of VIDEO SystemAdjustment

The adjustment items of video system adjustment are as listed inTable 6-1-2. The Automatic Adjustment Program executes the ad-justment items if the VIDEO Adjustment Start button is clicked.

ButtonAdjustment Signal Page AddressName

VIDEO VIDEO OutputAdjustment Level Adj.

Arbitrary 8F D0

Table 6-1-2

5

4

32

1

6-11DSC-T7

SEUS operation screen

Fig. 6-1-14

Check on the oscilloscope

Fig. 6-1-15

1-3-3. Adjusting Method[Automatic Adjustment Program execution items andsequence]1. Data Setting during Video Adj.2. Video Output Level Adj.3. Release of Data Setting during Video Adj.

[Specified value of video output level adj.]

Measurement Point Video terminal of Interfaceadaptor (75 Ω terminated)

Measuring Instrument Oscilloscope

Specified Value Sync level:A = 286 ± 5 mV (NTSC mode)A = 300 ± 5 mV (PAL mode)

Burst level:B = 286 ± 25 mV (NTSC mode)B = 300 ± 25 mV (PAL mode)

[Adjusting method]1) Click the [Start] button of the VIDEO Adjustment.2) The Automatic Adjustment Program executes the “1. Data Set-

ting during Video Adj.”.3) If “1. Data Setting during Video Adj.” completed successfully,

the next message is displayed during the execution of “2. VideoOutput Level Adj.”. Using the UP/DOWN key on the SEUSOperation screen, adjust so that the sync level of the videosignals satisfies the specified value. After the adjustment, checkthat the burst level of the video signals satisfies the specifiedvalue, and click the [OK] button in the message.

Fig. 6-1-12

4) If the [OK] button button is clicked, “3. Release of Data Set-ting during Video Adj.” will be executed.

5) Upon successful completion of all items of the VIDEO Ad-justment, the following message is displayed. Click the [OK]button.

Fig. 6-1-13

UP/DOWN key

H

A

B

6-12DSC-T7

1-4. CAMERA SYSTEM ADJUSTMENTS

1-4-1. Function of Each Button on Camera SystemAdjustment Screen

Click the [CAMERA SYSTEM ADJUSTMENT] button on the MainMenu screen, and the “CAMERA SYSTEM ADJUSTMENT”screen in Fig. 6-1-16 will appear.

Fig. 6-1-16

1 [To Menu] buttonThe Main Menu screen comes back.

2 [Preparation] buttonNotes for adjustment or jigs used are displayed.

3 [Start] buttonEach adjustment from “Camera Adjustment 1” to “CameraAdjustment 5” starts.

4 [Reset] buttonThis button functions same as the “Initialize” of the setupscreen.

5 [Release Data Setting] buttonThe data setting at the adjustment is cancelled.During the data setting, the button color changes from “white”to “red”. When the data setting is cancelled, the button colorreturns to “white”.(Use this button when an error occurred in the camera adjust-ment 1-5. If the adjustment completed successfully, the datasetting is automatically cancelled and the button color returnsto “white”.)

5

4

3

2

1

6-13DSC-T7

1-4-2. Adjustment Items of Camera System Adjust-ment

The adjustment items of camera system adjustment are as listed inTable 6-1-3. The Automatic Adjustment Program divides the ad-justment items into five, camera adjustment 1-5. Clicking eitherCAMERA Adjustment Start button allows the adjustment itemwhich corresponds to that button to be executed.The adjustment conditions of the subject and filter vary depend-ing on which item is adjusted. The Adjustment Program displaysan instruction for the subject and filter as a message during theadjustment.

Button Name Adjustment SubjectAdjustment Adjustment

Page Address

(Note 1) Wide Limit Adj. Not required 6F 18, 19

Siemens star chart with ND filterCAMERA Adjustment 1 Flange Back Adj. for minipattern box (Note 2) or 6F 18 to 3F, 52, 53

Flange back adjustment jig

Siemens star_ _

CAMERA Adjustment 2 Flange Back Check (1.0m from front the lens)(Luminance: 200 to 400 lux)

F No. Compensation 6F 60, 61, 6B to 6D

Measure Gain Adj.

Clear chart

6F 6B, 6F

CAMERA Adjustment 3

(Standard picture frame)

78 0C to 0F

Mechanical Shutter Adj.6F

6B to 6D, B8 to BD,C7 to C9

7940 to 42, 45 to 47,4A

Light Value Adj. 6F 65 to 67

AWB 3200K-5800K 9 colors chart 6E 00 to 21, 24 to 49(Note 3)Standard Data Input (Standard picture frame)

Color Reproduction 9 colors chart 6E 60 to 67Adj. & Check (Standard picture frame)

CCD Linearity Check _ _

CAMERA Adjustment 4 CCD White Defect Clear chart _ _Compensation Check (Standard picture frame)

_

_CCD Black DefectCompensation Check

Strobe Adj.6E 72 to 75

CAMERA Adjustment 5 Flash adjustment box (50 cm) 6F D8 to EF

Auto focus illumination Check 6F 10 to 15

Note 1: The Automatic Adjustment Program does not support the “Wide Limit Adjustment”.Note 2: Dark Siemens star chart.Note 3: Use the AWB Adjustment Program (T7AwbAdjustment.exe).

Table 6-1-3

6-14DSC-T7

1-4-3. Adjusting Method1. Wide Limit AdjustmentAdjustment to remove variations at the wide end of the inner fo-cus lens.

Adjustment Page 6F

Adjustment Address 18, 19

1-1. Adjusting method when the lens is replaced:

Adjusting method:

Order Page Address Data Procedure

1 00 01 01 Set the data.

2 40 38 00 Set the data.

3 6F 18 Set the data. (Note)

4 6F 19 Set the data. (Note)

5 7C 16 01 t 00 Change the data.(The data is OK if it is “00”.)

6 Save the data.

7 Wait for 2 sec.

8 Perform “Flange BackAdjustment”.

Note: The data of page: 6F, address: 18 and 19, that are set in theOrders 2 and 3 as described above, are shown on the datasheet supplied with the replacement lens for repair.Set the upper single byte of the 2-byte data shown on thesheet to address: 18, and the lower byte of the data to theaddress: 19.

Fig. 6-1-17

1-2. Adjusting method when replacement of lensis not required and the SY-115 board is replaced:

When the data of page: 6F, address: 18 and 19 can beread from the defective SY-115 board before replace-ment, and both of the data are not “00”:

Adjusting method:

Order Page Address Data Procedure

1 00 01 01 Set the data.

2 40 38 00 Set the data.

3 6F 18 Set the previous data

4 6F 19 Set the previous data

5 7C 16 01 t 00 Change the data.(The data is OK if it is “00”.)

6 Save the data.

7 Wait for 2 sec.

8 Perform “Flange BackAdjustment”.

When the data of the page: 6F, address: 18 and 19 canbe read out from the defective SY-115 board beforereplacing it, and both of the data are “00”:1) Replace the lens with the replacement lens and perform “1-1.

Adjusting method when the lens is replaced”.

When the data of page: 6F, address: 18 and 19 cannotbe read from the defective SY-115 board:1) Replace the lens with the replacement lens and perform “1-1.

Adjusting method when the lens is replaced”.

Note: The data of page: 7C, address: 16, that is set in the Order 4of the adjusting method of 1-1 or 1-2, is “01” when shippedfrom the factory. Let the data remain “00” after comple-tion of the service adjustment.

Data for Page: 6F, Address: 19

2-byte data

Data for Page: 6F, Address: 18

XXXX

6-15DSC-T7

2. CAMERA Adjustment 1[Automatic Adjustment Program execution items andsequence]1. Data Setting during Camera Adj.2. Flange Back Adj.3. Release of Data Setting during Camera Adj.

Preparation of Flange Back Adj.(Using the minipattern box)1) The minipattern box is installed as shown in the following fig-

ure.Note: The attachment lenses are not used.

2) Install the minipattern box so that the distance between it andthe front of lens of camera is less than 3 cm.

3) Make the height of minipattern box and the camera equal.4) Check the output voltage of the regulated power supply is the

specified voltage ± 0.01 Vdc.5) Check that the center of Siemens star chart meets the center of

shot image screen with the zoom lens at TELE end and WIDEend respectively.

Specified voltage: The specified voltage varies according to theminipattern box, so adjustment the power sup-ply output voltage to the specified voltage writ-ten on the sheet which is supplied with the mini-pattern box.

Fig. 6-1-21

Preparation of Flange Back Adj.(Using the flange back adjustment jig)(Luminance: about 300 lux)1) Install the flange back adjustment jig so that the distance be-

tween it and the front of lens of camera is less than 3 cm.2) Make the height of flange back adjustment jig and the camera

equal.3) Check that the center of chart meets the center of shot image

screen with the zoom lens at TELE end and WIDE end respec-tively.

Fig. 6-1-22

Minipattern box

Below 3 cm

Camera

Red (+)

Black (–)

Yellow (SENS +)

White (SENS –)

Black (GND)

Need not connected

Regulated power supplyOutput voltage : Specified voltage ± 0.01 Vdc

Output current : more than 3.5 A

Flange back adjustment jigBelow 3 cm

Camera

[Adjusting method]1) If the [Start] button of the CAMERA Adjustment 1 is clicked,

the following message is displayed.If “Wide Limit Adjustment” is necessary, click the [Cancel]button to interrupt the Adjustment Program, and perform “1.Wide Limit Adjustment”.

Fig. 6-1-18

2) If the [OK] button is clicked, the Automatic Adjustment Pro-gram executes “1. Data Setting during Camera Adj.”.

3) Upon successful completion of the “1. Data Setting duringCamera Adj.”, the following message is displayed. Set the sub-ject by referring to “Preparation of Flange Back Adj.”.

Fig. 6-1-19

4) If the [OK] button is clicked, “2. Flange Back Adj.” and “3.Release of Data Setting during Camera Adj.” will be executed.

5) Upon successful completion of all items of the CAMERAAdjustment 1, the following message is displayed. Click the[OK] button.

Fig. 6-1-20

6-16DSC-T7

3. CAMERA Adjustment 2[Automatic Adjustment Program execution items andsequence]1. Data Setting during Camera Adj.2. Flange Back Check3. Release of Data Setting during Camera Adj.

[Adjusting method]1) Click the [Start] button of the CAMERA Adjustment 2.2) The Automatic Adjustment Program executes “1. Data Setting

during Camera Adj.”.3) Upon successful completion of the “1. Data Setting during

Camera Adj.”, the following message is displayed. Set the sub-ject in accordance with the message.

Fig. 6-1-23

4) Click the [OK] button is clicked, “2. Flange Back Check” isexecuted. The following messages are displayed, and then op-erate the camera to make a check in accordance with the mes-sages.

Fig. 6-1-24

5) Upon completion of “2. Flange Back Check”, “3. Release ofData Setting during Camera Adj.” is executed.

6) Upon successful completion of all items of the CAMERAAdjustment 2, the following message is displayed. Click the[OK] button.

Fig. 6-1-25

4. Picture Frame Setting (Standard Picture Frame)In the “CAMERA Adjustment 3”, “AWB 3200K-5800K StandardData Input” and “CAMERA Adjustment 4”, set the picture frameso as to attain the positions shown in the following figure whenshooting the 9 colors chart.

Check on the oscilloscope

Measurement Point:Video terminal of Interface adaptor(75Ω terminated)

1. Horizontal period

Fig. 6-1-26

2. Vertical period

Fig. 6-1-27

Check on the monitor TV or the LCD screen

Fig. 6-1-28

AA B

A = B

V

BC C

C = B3

Transparent window

Effective picture frame

A AB

BlueC14 Magenta

WhiteCyan Red

YellowGreen W14

C

C

B

C =A = B

C14: Filter for AWB 5800K adjustment

A2

B3

6-17DSC-T7

5. CAMERA Adjustment 3[Automatic Adjustment Program execution items andsequence]1. Data Setting during Camera Adj.2. Picture Frame Setting3. F No. Compensation4. Measure Gain Adj.5. Mechanical Shutter Adj.6. Light Value Adj.7. Release of Data Setting during Camera Adj.

[Adjusting method]1) Click the [Start] button of the CAMERA Adjustment 3.2) The Automatic Adjustment Program executes the “1. Data Set-

ting during Camera Adj.”.3) Upon successful completion of “1. Data Setting during Cam-

era Adj.”, “2. Picture Frame Setting” is executed. The follow-ing message is displayed, and then referring to Fig. 6-1-26 toFig. 6-1-28 (See page 6-16), set the subject and click the [OK]button.

Fig. 6-1-29

After that, the next message is displayed. Then, change the chartin accordance with the message.

Fig. 6-1-30

4) Click the [OK] button, and the items from “3. F No. Compen-sation” to “7. Release of Data Setting during Camera Adj.”will be executed.

5) Upon successful completion of all items of the CAMERAAdjustment 3, the following message is displayed. Click the[OK] button.

Fig. 6-1-31

6-18DSC-T7

6. AWB 3200K-5800K Standard Data Input[Adjustment method]1) Start the AWB Adjustment Program (T7AwbAdjustment.exe).2) Click the [Connect] button to set the camera to the adjust-

ment mode.

Fig. 6-1-32

3) Adjust the mode switch of the camera to “CAMERA” and setMACRO mode. Shoot the 9 colors chart with the zoom at WIDEend.

4) Adjust the camera direction and distance to set the pictureframe. (Refer to 4. Picture Frame Setting)

5) Click the [AWB 3200K-5800K Standard Data Input] button.

Fig. 6-1-33

6) A picture captured by the camera is displayed on the screen,and the adjustment and checking are performed.

Fig. 6-1-34

Note: If the following message is displayed, the picture framesetting is faulty. Check the picture frame, and then performreadjustment.

Fig. 6-1-35

7) Upon successful completion of the adjustment, the followingmessage is displayed. Click the [OK] button.

Fig. 6-1-36

8) Perform the “Camera Adjustment 4” successively without turn-ing off the power switch of the camera.

6-19DSC-T7

At this time, the following message is displayed, and click the[Yes] button if the check result display at the upper right ofColor Reproduction Check screen is OK, or the [No] button ifNG.

Fig. 6-1-39

5) Upon successful completion of “3. Color Reproduction Adj.& Check”, the following message is displayed. Change thechart in accordance with the message.

Fig. 6-1-40

6) Click the [OK] button, and the items from “4. CCD LinearityCheck” to “7. Release of Data Setting during Camera Adj.”will be executed.

7) Upon successful completion of all items of the CAMERAAdjustment 4, the following message is displayed. Click the[OK] button.

Fig. 6-1-41

7. CAMERA Adjustment 4Note: After executing the “AWB 3200-5800K Standard Data In-

put” perform the “CAMERA Adjustment 4” successivelywithout turning off the power switch of the camera.

[Automatic Adjustment Program execution items andsequence]1. Data Setting during Camera Adj.2. Picture Frame Setting3. Color Reproduction Adj. & Check4. CCD Linearity Check5. CCD White Defect Compensation Check6. CCD Black Defect Compensation Check7. Release of Data Setting during Camera Adj.

[Adjusting method]1) Click the [Start] button of the CAMERA Adjustment 4.2) The Automatic Adjustment Program executes the “1. Data Set-

ting during Camera Adj.”.3) Upon successful completion of “1. Data Setting during Cam-

era Adj.”, “2. Picture Frame Setting” is executed. The follow-ing message is displayed, and then referring to Fig. 6-1-26 toFig. 6-1-28 (See page 6-16), set the subject and click the [OK]button.

Fig. 6-1-37

4) After that, “3. Color Reproduction Adj. & Check” will be ex-ecuted. Upon completion of adjustment, the check result isdisplayed on the Color Reproduction Check screen.

Fig. 6-1-38

6-20DSC-T7

8. CAMERA Adjustment 5Note: “CAMERA Adjustment 5” is available only once after the

power is turned on. If the adjustment is retried, turn off thepower and turn on again.

[Automatic Adjustment Program execution items andsequence]1. Data Setting during Camera Adj.2. Strobe Adj.3. Auto Focus Illumination Check4. Release of Data Setting during Camera Adj.

[Adjusting method]1) Click the [Start] button of CAMERA Adjustment 5.2) The Automatic Adjustment Program executes the “1. Data

Setting during Camera Adj.”.3) Upon successful completion of the “1. Data Setting during

Camera Adj.”, the following message is displayed. Set the sub-ject in accordance with the message.(For the Flash adjustment box, refer to “3. Preparing the FlashAdjustment Box” (see page 6-6).)

Fig. 6-1-42

4) Press the [OK] button, and the “2. Strobe Adj.” will be ex-ecuted.

5) During execution of “2. Strobe Adj.”, the following messageis displayed. After checking the flashing of strobe light, clickthe [OK] button. (This message is displayed 2 times duringexecution of adjustment.)

Fig. 6-1-43

6) Upon successful completion of “2. Strobe Adj.”, “3. Auto Fo-cus Illumination Check” is executed.

7) Upon successful completion of the “3. Auto Focus Illumina-tion Check”, the “4. Release of Data Setting during CameraAdj.” will be executed successively.

8) Upon successful completion of all items of the CAMERAAdjustment 4, the following message is displayed. Click the[OK] button.

Fig. 6-1-44

6-21DSC-T7

1-5. LCD SYSTEM ADJUSTMENTS

1-5-1. Function of Each Button on LCD SystemAdjustment Screen

Click the [LCD SYSTEM ADJUSTMENT] button on the MainMenu screen, and the “LCD SYSTEM ADJUSTMENT” screen inFig. 6-1-45 will appear.

Fig. 6-1-45

1 [To Menu] buttonThe Main Menu screen comes back.

2 [Start] button“LCD Adjustment” starts.

3 [Reset] buttonThis button functions same as the “Initialize” of the setupscreen.

4 [Release Data Setting] buttonThe data setting at the adjustment is cancelled.During the data setting, the button color changes from “white”to “red”. When the data setting is cancelled, the button colorreturns to “white”.(Use this button when an error occurred in the LCD adjust-ment. If the adjustment completed successfully, the data set-ting is automatically cancelled and the button color returns to“white”.)

4

3

2

1

1-5-2. Adjustment Items of LCD System AdjustmentThe adjustment items of LCD system adjustment are as listed inTable 6-1-4. The Automatic Adjustment Program executes the ad-justment items if the LCD Adjustment Start button is clicked.

ButtonAdjustment Signal Page AddressName

LCDCOM AC adj. 8F 10V-COM adj. Arbitrary 8F 11

AdjustmentWhite Balance adj. 8F 42, 43, 58, 59

Table 6-1-4

6-22DSC-T7

1-5-3. Adjusting Method[Automatic Adjustment Program execution items andsequence]1. Data Setting during LCD Adj. & EVR Data Write2. COM AC Adj.3. V-COM Adj.4. White Balance Adj.5. Release of Data Setting during LCD Adj.

[Adjusting method]1) Click the [Start] button of the LCD Adjustment.2) The Automatic Adjustment Program executes “1. Data Setting

during LCD Adj. & EVR Data Write” and “2. COM AC Adj.”.3) Upon successful completion of the “2. COM AC Adj.”, the

following message is displayed during execution in “3. V-COMAdj.”. On the SEUS screen, operate the UP/DOWN key sothat the brightness of portions A and B on the LCD panel isequal. After the adjustment, click the [OK] button.

Fig. 6-1-46

4) Upon completion of “3. V-COM Adj.”, “4. White Balance Adj.”is executed. The following message is displayed, and then checkthat LCD screen is not colored.If colored, change the data of page: 8F, address: 42 and 43 onthe SEUS Operation screen to adjust so that the LCD screen isnot colored.

Fig. 6-1-47

5) If the [OK] button is clicked, “5. Release of Data Setting dur-ing LCD Adj.” will be executed.

6) Upon successful completion of all item the LCD Adjustment,the following message is displayed. Click the [OK] button.

Fig. 6-1-48

SEUS operation screen

Fig. 6-1-49

Check on the LCD screen (V-COM Adj.)

Fig. 6-1-50

UP/DOWN key

A B

6-23DSC-T7

1-6. ERROR

In case of an error during the execution of adjustment, the Auto-matic Adjustment Program interrupts the processing at that point,and displays an error message, and then terminates the programexecution there.

1-6-1. Error MessageWhen an error message is displayed, perform the remedy givenbelow, and then retry adjustment. If the error message is displayedthough the remedy was performed, the circuits will be faulty.

1. Connect Error

Fig. 6-1-51

Symptom USB communication with the set is abnormal.

Cause • USB cable is not inserted tightly.• Power supply is not installed correctly.• Communication with SEUS is abnormal.

Remedy • Disconnect the USB cable once, and then re-connect it tightly and check that the set is in“USB Mode”.

• Install the power supply correctly.• Start the SEUS and click the [Connect] to

check that the connection state is established.

2. RESET the CAMERA and Try Again

Fig. 6-1-52

Symptom The camera is not ready for adjustment.

Cause • Data error exists in the camera.

Remedy • Reset the camera.

3. Adjustment Time Out

Fig. 6-1-53

Symptom Adjustment does not finish within the specifiedtime.

Cause • Adjustment conditions are wrong.• Data error exists in the camera.

Remedy • Check that the conditions such as a subjectare correct.

• Reset the camera.

4. Adjustment NG

Fig. 6-1-54

Symptom The adjusted data does not become the speci-fied value.

Cause • Adjustment conditions are wrong.• Data error exists in the camera.

Remedy • Check that the conditions such as a subjectare correct.

• Reset the camera.

This part indicates the adjustment item in which an error occurred.

This part indicates the adjustment item in which an error occurred.

6-24DSC-T7

5. Data Save Error

Fig. 6-1-55

Symptom data cannot be saved normally. (The data set-ting during adjustment cannot be cancelled)

Cause • Data writing to the flash memory failed.• Connection is faulty.• Power supply is not installed correctly.

Remedy • On the SEUS Operation screen, [Set] the datato the pages and addresses displayed in themessage, and [Save] them. (Cancel manu-ally the data setting during adjustment.)

• Check the connection.• Install the power supply correctly.

1-6-2. Precautions When an Error OccurredThe Automatic Adjustment Program sets the data for adjustmentbefore the adjustment starts. Accordingly, if the adjustment termi-nates by an error, the data during the adjustment may be left in thecamera.Note 1: With this data left in the camera, the camera will not

operate normally.

In this case, the [Release Data Setting] button is displayed in “red”on the screen as shown in Fig. 6-1-56, 57 and 58. Click the[Release Data Setting] button to cancel the data setting. When thedata setting is cancelled, the button color becomes “white”.Note 2: When “Data Save Error” occurred, the [Release Data

Setting] button is displayed in “white”.To cancel the data setting, perform it on the SEUS Op-eration screen. How to cancel the data setting is displayedin the error message.

Video System Adjustment screen

Fig. 6-1-56

Camera System Adjustment screen

Fig. 6-1-57

LCD System Adjustment screen

Fig. 6-1-58

How to cancel the data setting during adjustment is display here.

6-25DSC-T7

1-7. INITIALIZATION OF DATA

1. Initializing All Page DataBy performing the following procedure, data of all pages will beinitialized.Note: If all page data have been initialized, all adjustments need

to be performed again.

Initializing Method:1) Select page: 00, address: 01 and set data: 01.2) Click [Sector Write] on the SEUS screen to display the SEUS

SECTOR WRITE screen.3) Check that the SET ID is “08”.4) Click [All] of the ALL SELECT buttons to select all pages.

(Fig. 6-1-49 A)5) Click [Write] to write the initializing data to the flash memory

of the camera.6) Wait for 3 sec.7) Click [Close] to close the SEUS SECTOR WRITE screen.8) Select page: 40, address: 38 and set data: 00.9) Select page: BC, address: F0 and set data: 02.10) Select page: 8F, address: 6C and set data: 0D.11) Select page: 8F, address: 6D and set data: 05.12) Click [Save] on the SEUS screen.13) Wait for more than 3 sec.14) Select page: 80, address: 30, and check that the data is “00”.

Processing after Completing Initializing

Order Page Address Data Procedure

1 40 28 01 [Set] (Note)

Note: At this time, the camera is reset and the power is turns offonce and then on again. Accordingly, the SEUS goes in“disconnect” state, but this is not a trouble. Click [Con-nect] on the SEUS screen to restore the “connected” state.(In case that the power does not turn on again, press thepower button.)

Fig. 6-1-59

2. Initializing Single Page DataBy performing the following procedure, data of the page that youwant to initialize will be initialized.Note 1: If the 6D or 6E or 6F or 78 or 79 page data have been

initialized, the following adjustment needs to be per-formed again.1) Camera system adjustments

Note 2: If the 8F page data have been initialized, the followingadjustment needs to be performed again.1) LCD system adjustments

Initializing Method:1) Select page: 00, address: 01 and set data: 01.2) Click [Sector Write] on the SEUS screen to display the SEUS

SECTOR WRITE screen.3) Check that the SET ID is “08”.4) Click “All” of the option buttons of target page. (Fig. 6-1-49B)

5) Click [Write] to write the initializing data to the flash memoryof the camera.

6) Wait for 3 sec.7) Click [Close] to close the SEUS SECTOR WRITE screen.8) Select page: 40, address: 38 and set data: 00.9) When BC page is initialized, select page: BC, address: F0 and

set data: 02.10) When 8F page is initialized, select page: 8F, address: 6C and

set data: 0D.11) When 8F page is initialized, select page: 8F, address: 6D and

set data: 05.12) Click [Save] on the SEUS screen.13) Wait for more than 3 sec.14) Select page: 80, address: 30, and check that the data is “00”.

Processing after Completing Initializing

Order Page Address Data Procedure

1 40 28 01 [Set] (Note)

Note: At this time, the camera is reset and the power is turns offonce and then on again. Accordingly, the SEUS goes in“disconnect” state, but this is not a trouble. Click [Con-nect] on the SEUS screen to restore the “connected” state.(In case that the power does not turn on again, press thepower button.)

B

A

08

6-26DSC-T7

6-2. SERVICE MODE

1. Setting the Test Mode

Page 40 Address A1, A3

• Forced CAMERA (Auto) mode1) Select page: 40, address: A1, and set data: 01.2) Select page: 40, address: A3, and set data: 01.

• Forced CAMERA (Program Auto) mode1) Select page: 40, address: A1, and set data: 01.2) Select page: 40, address: A3, and set data: 02.

• Forced MOVIE mode1) Select page: 40, address: A1, and set data: 01.3) Select page: 40, address: A3, and set data: 07.

• Forced PLAY mode1) Select page: 40, address: A1, and set data: 01.2) Select page: 40, address: A3, and set data: 08.

• After completing adjustments/repairs, release the data setting.1) Select page: 40, address: A1, and set data: 00.

2. Bit Value DiscriminationIn the following items, the bit values must be discriminated fromthe data displayed on the SEUS. Whether bit values are “1” or “0”can be discriminated from the table shown below.

Data displayed on SEUS

0 0bit 3 to bit 0 discriminated

bit 7 to bit 4 discriminated

Bit values

Display on the bit3 bit2 bit1 bit0SEUS or or or or

bit7 bit6 bit5 bit4

0 0 0 0 0

1 0 0 0 1

2 0 0 1 0

3 0 0 1 1

4 0 1 0 0

5 0 1 0 1

6 0 1 1 0

7 0 1 1 1

8 1 0 0 0

9 1 0 0 1

A 1 0 1 0

B 1 0 1 1

C 1 1 0 0

D 1 1 0 1

E 1 1 1 0

F 1 1 1 1

B

A

Example: If the displayed data is “8E”, bit 7 - bit 4 values can bediscriminated from block (A), and also bit 3 - bit 0 val-ues from block (B).

6-27DSC-T7

3. LED Check

Page 80 Address 12

Page 8E Address FE

Using method:1) Select page: 00, address: 01, and set data: 01.2) Select page: 8E, address: FE, and set data: 20.3) Select page: 80, address: 12, and set data: 01.4) Check that all LED are lit.

• SELF TIMER/AF ILLUMINATOR• FLASH CHARGE• MS ACCESS

5) Select page: 80, address: 12, and set data: 00.6) Select page: 8E, address: FE, and set data: 00.7) Select page: 00, address: 01, and set data: 00.8) Click [Disconnect] on the SEUS screen.9) Disconnect the USB cable.10) Turn off the power.

4. Switch Check (1)

Page 80 Address 13

Using method:1) Select page: 80, address: 13.2) By discriminating the read data, the state of the switches can

be discriminated.

Function When data = 00 When data = 01 When data = 02

Shutter button(XAE LOCK SW) OFF ON ON(CONTROL SWITCH BLOCK (RL51710) S002)

Shutter button(XSHUTTER SW) OFF OFF ON(CONTROL SWITCH BLOCK (RL51710) S002)

6-28DSC-T7

5. Switch Check (2)

Page 20 Addresses A0, A1

Using method:1) Select page: 20, addresses: A0 and A1.2) By discriminating the read data, the pressed key can be dis-

criminated.

6. Mode Switch Check

Page 20 Addresses A3

Using method:1) Select page: 20, addresses: A3.2) By discriminating the read data, the state of the mode dial can be discriminated.

7. Self Diagnosis Code

6-28E

Note: After repair, be sure to execute the “Initialize” of the setup screen.

AddressData

00 to 15 16 to 3E 3F to 63 64 to 91 92 to D8 D9 to FF

A0CONTROL DOWN CONTROL RIGHT CONTROL UP CONTROL LEFT CONTROL SET

(KEY AD0)(Control switch block) (Control switch block) (Control switch block) (Control switch block) (Control switch block)

No key input(IC301 K23 )

(GP51710) (GP51710) (GP51710) (GP51710) (GP51710)(S001) (S002) (S003) (S004) (S006)

A1MENU IMAGE SIZE/ DISPLAY/ ZOOM W ZOOM T

(KEY AD1)(Control switch block) DELETE LCD ON/OFF (Control switch block) (Control switch block)

No key input(IC301 L23 )

(GP51710) (SW-454 flexible) (SW-454 flexible) (RL51710) (RL51710)(S005) (S001) (S002) (S003) (S004)

AddressData

00 to 17 18 to 3C 3D to 59 5A to 6E 6F to 8E 8F to FF

A3 MOVIE PLAY AUTO(MODE DIAL0) – (Control switch block) (Control switch block) (Control switch block) – –(IC301 L22 ) (RL51710) (RL51710) (RL51710)

Display Code

C:32:ss

C:13:ss

Countermeasure

Turn the power off and on again.

Format the “Memory Stick Duo”.

Insert a new “Memory Stick Duo”.

Caution Display During Error

SYSTEM ERROR

FORMAT ERROR

MEMORY STICK ERROR

E:61:ss

E:91:ss

Checking of lens drive circuit.

Checking of flash unit or replacementof flash unit. (Note)

Cause

Trouble with hardware.

Unformatted “Memory Stick Duo” is inserted.

“Memory Stick Duo” is broken.

When failed in the focus and zoominitialization.

Abnormality when flash is beingcharged.

SONY BRASIL LTDA.ENGENHARIA DA QUALIDADE

JULHO / 2005

http://www.sony.com.br

ENGENHARIA DA QUALIDADESony Brasil Ltda.

Guia de Comandos Básicos do Acrobat Reader 5.05

Esta é a tela do programa, quando se abre um manual:

Abra a página correspondente ao diagrama em

bloco e posicione o ponteiro do mouse sobre o

IC escolhido . Quando o cursor tornar-se uma

“mãozinha” dê um clique sobre o IC.

Barra de Comandos

Recurso de Localização de Componentes

Alguns manuais de serviço estão habilitados com uma função que permite localizar mais

facilmente um circuito integrado (IC) em seu diagrama esquemático correspondente, diagrama em

blocos ou placa de circuito impresso.

Para isso, abra um manual de serviço, por exemplo o do MHC-DX30 e visualize uma página

da lista de peças elétricas, onde existam alguns IC’s listados. Ao posicionar o ponteiro do mouse sobre

a linha onde está um IC, sobre sua localização, ou valor, você vai verificar que aparece uma

“mãozinha”, na verdade, o dedo indicador que fica apontando a linha. Se você der um clique, você

será levado pelo programa à pagina do diagrama esquemático onde se encontra o referido IC que você

selecionou. Vamos ilustrar o que foi explicado logo a seguir:

Notas

• O tamanho da visualização do documento na tela em nada altera o tamanho de impressão. O Zoom

de aumento ou de diminuição serve apenas para oferecer mais detalhes ou um aspecto geral do

documento visualizado.

O programa trará você à página do diagrama

esquemático correspondente que contém o

IC escolhido. Clique novamente sobre o IC.

O programa trará você à página

correspondente a placa de circuito impresso

que contém o IC escolhido. Clique novamente

sobre o IC. sobre o IC.

Por fim o programa visualiza o ponto da lista

de peças onde o IC escolhido está localizado.

Ao clicar novamente sobre o componente o

cliclo se repete (diagrama em bloco,

esquemático, placa de circuito impresso e

lista de peças. Vale lembrar que nem todos os

manuais de serviço possuem esse recurso.

• O painel de navegação serve para agilizar o acesso a outras páginas que não estão sendo

visualizadas. Para visualizar uma dessas miniaturas em seu tamanho normal, basta clicar duas

vezes sobre ela e então esta será exibida na tela.

• Não é possível alterar texto, figuras ou qualquer item do documento no Acrobat Reader 5.0. Este

programa é usado somente para visualização e impressão de documentos PDF.

• Diagramas e demais folhas do documentos PDF só poderão ser impressos em tamanho maior caso

a impressora suporte papel com dimensão superior ao A4, carta ou semelhante. Do contrário só

poderá ser impresso no tamanho A4 padrão.

Engenharia da Qualidade – Novembro 2003

[email protected]

Engenharia da Qualidade - SSP Sony Brasil Ltda.

Orientação de Impressão no Acrobat Reader 5.05

É possível imprimir alguns quadros pré-selecionados de forma ampliada no Acrobat Reader. Esse comando é muito útil quando é necessária fazer a impressão de diagramas elétricos.

A sequência abaixo mostra, passo a passo como selecionar uma parte de uma folha

qualquer (nesse exemplo usaremos um diagrama elétrico) e configurar sua impressão. Temos no Acrobat Reader a barra abaixo. Leve o cursor do mouse até o botão indicado pela seta e fique pressionando o botão do mouse. Segurando o botão uma barra oculta aparecerá, então expanda conforme abaixo. O botão final a ser clicado para que o comando seja selecionado é o da FERRAMENTA DE SELEÇÃO DE GRÁFICO (G)

VOLTAR

Teruaki_Nakagawa
VOLTAR

Agora com o cursor selecione uma área do diagrama que deseja imprimir de forma ampliada. A

área escolhida nesse exemplo é o quadrado de linhas espessas.

Agora vá até o menu de impressão seguindo o procedimento a seguir, clicando em IMPRIMIR, indicado pela seta:

Na janela que se abre verifique se as opções indicadas em vermelho (circuladas) estão habilitadas.

Assim, quando imprimir a área do gráfico, esta parte será expandida por toda a folha de papel A4.

Após a impressão verificamos que o diagrama ficou realmente ampliado, conforme exemplo:

Notas

O mesmo procedimento pode ser repetido para outras páginas dos manuais, como lista de

peças, bem como pode ser utilizado papel tamanho A3 (420 x 297 mm) para impressoras que

suportem esse formato.

Outros comandos podem ser encontrados no “Guia de Comandos Básicos do Acrobat

Reader”, que também consta neste CD e em anteriores.

Lembramos novamente que não é possível alterar texto, figuras ou qualquer item do

documento no Acrobat Reader 5.05. Este programa é usado somente para visualização e impressão

de documentos PDF.

Mais informações podem ser obtidas em “Ajuda”.

Dúvidas e sugestões devem ser encaminhadas para Teruaki através do e-mails:

[email protected]